7/29/2019 501 Manual
1/8
Model 501
Insulation TesterINSTRUCTION MANUAL
16
SIMPSON ELECTRIC COMPANY 520 Simpson AvenueLac du Flambeau, WI 54538-0099 (715) 588-3311 FAX (715) 588-3326
Printed in U.S.A. Part No. 06-116817 Edition 3, 06/07Visit us on the web at: www.simpsonelectric.com
7/29/2019 501 Manual
2/8
7/29/2019 501 Manual
3/8
3
SHOCK HAZARD: As defined in American National Standard, C39.5, SafetyRequirements for Electrical & Electronic Measuring & Controlling Instrumenta-tion, a shock hazard shall be considered to exist at any part involving a potentialin excess of 30 volts RMS (sine wave) or 42.4 volts DC or peak and where aleakage current from that part to ground exceeds 0.5 milliampere, when mea-sured with an appropriate measuring Instrument defined in Section 11.6.1 ofANSI C39.5.
NOTE: The proper measuring Instrument for the measurement of leakage cur-rent consists essentially of a network of a 1500 ohm non-inductive resistor shuntedby a 0.15 microfarad capacitor connected between the terminals of the measur-ing Instrument. The leakage current is that portion of the current that flows throughthe resistor. The Simpson Model 229-Series 2 AC Leakage Current Tester meetsthe ANSI C39.5 requirements for the measurement of AC leakage current andcan be used for this purpose. To measure DC Leakage current, connect a 1500ohm non-inductive resistor in series with a Simpson 0-500 DC microammeterand use this as the measuring Instrument.
14
8.5. Technical Assistance
Simpson Electric Company offers assistance Monday thru Friday 7:30 a.m. -5:00 p.m. Central Time. Contact Technical Support or Customer Service at (847)697-2260.
9. NIST CERTIFICATION
Simpson Electric Company Standards Lab has the technical expertise and properfacility to handle National Institute of Standards and Technology (NIST) certifica-tion. Simpsons Quality Assurance Calibration System satisfies the requirementsof MIL-I-45208A, MIL-I-45662A and ANSI/NCSL Z540-1-1994. For a nominalcharge you can certify that your Instrument has been calibrated under controlledenvironmental conditions to the manufacturers specifications. Just call a SimpsonCustomer Service Representative at (847) 697-2260.
7/29/2019 501 Manual
4/8
7/29/2019 501 Manual
5/8
7/29/2019 501 Manual
6/8
6
2. SAFETY PRECAUTIONS
This insulation tester is constructed and tested in accordance with the followingstandards:IEC 1010-1/EN 61010-1: IEC 1557-2/EN 61557-2: IEC 1557-4/EN 61557-4.To ensure safe operation and to prevent damage to the Instrument, read and
follow all instructions in this operating manual before using Instrument.
2.1 Repair and Replacement of Parts
When operating the tester, live parts may become exposed. Disconnect from allvoltage sources before repairing or replacing parts. Only qualified personnelshould replace or repair parts if Instrument must stay connected to voltage sources.
Faults and Unusual Stress
Operating the Instrument safely may be no longer possible if:a. Instrument is visibly damaged.
b. Instrument no longer performs.c. Instrument is stored for long period under unfavorable conditionsd. Instrument has endured heavy transport.
For safety reasons connected test leads are double-insulated. Each insulationhas a different color making damage to the outer insulation noticeable beforeinner insulation is affected.
3. OPERATION
3.1 Inserting Batteries
Be sure that the function switch is in the 1000V position before opening thebattery compartment and that the Instrument is disconnected from all externalcurrent circuits.
1. Unscrew lid to the battery compartment.2. Insert 6 standard 1.5 V batteries (D size) into the battery compartment match-
ing symbols on batteries with the symbols on Instrument3. Replace compartment lid and screws.
3.2 Testing Batteries
Pressing the test key automatically tests the batteries. The instantaneous load istaken into account by the selected position of the function switch and the nominalvoltage. Signal light on the left of the scale shows battery condition as follows:
Green: Batteries are fully chargedRed: Batteries are too weak for the selected type of measurement
11
tseT
noitcnuF
gnirusaeM
egnaR
rorrE
cisnirtnI
ecner
efeRhtiw
sn
oitidnoC
)1
gnitarepO
rorrE
lanimoN
UegatloV
N
)4
ycneuq
erF
daoL-oN
UegatloV
o
tiucriCtrohS
ItnerruC
k
)2
lanretnI
RecnatsiseR
i
ehtnipmaL
htiweborptset
ecnatsiser
)3
daolrevO
eulaV
emiT
xxV0001
V0001
0
%
5.2
%01
zH002
04ro0
k009
V0021
.tnoC
3R,
2R,
1R
UN
V05=
k05
0
%
5.1
%52
V05
V06
Am21
V0021
s01.x
aM
k02
M1
k01
k002
M02
k04
,3R,
2R,
1
R
UN
V001=
k001
0
%
5.1
%52
V001
V021
k06
k002>
V0021
s01.x
aM
k04
M2
k02
k004
M04
k08
,3R,
2R,
1
R
UN
V052=
k052
0
%
5.1
%52
V052
V003
k051
k005>
V0021
s01.x
aM
k001
M5
k05
M1
M001
k002
,3R,
2R,
1
R
UN
V005=
k005
0
%
5.1
%52
V005
V006
k003
M1>
V0021
s01.x
aM
k002
M01
k001
M2
M002
k004
,3R,
2R,
1
RUN
V0001=
M1
0
%
5.1
%52.
V0001
V0021
k006
M2>
V0021
s01.x
aM
k004
M02
k002
M4
M004
k008
4
4
0
%
5.1
%01
V9
Am002>
A
513.0
.tnoC
7. TECHNICAL SPECIFICATIONS
1 Referred to the scale length2 With the electrical zero point adjusted correctly
Table 7-13 Switching accuracy4 Normal current IN 1 mA