GILLAM – FEi
Written by : M. CORNET J. MATHIEU Date : 20/01/2012
Ref. Doc. : 4399MC-JMbf_GB Revision 4 GILLAM - FEi Mont Saint-Martin 58 4000 LIEGE �: (+32) 4 / 232 95 95 - Fax: (+32) 4 / 223 42 76 BELGIUM E-mail : [email protected] Internet : www.gillam-fei.be
UNISYNCe – US5Ge
Graphical User Interface
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge 20/01/2012 Graphical User Interface
REV. Date Subject Modified
Pages
0 23/01/06 First release All
1 25/01/06
2 October 06 Update New pictures + note on
release 9.6
3 October 07 Update
4 January 12 Addition new § 2.6.1 + 2.6.2
Copyright 2000 GILLAM Group, Mont Saint Martin, 58, B-4000 Liège , Belgium
The content of this document is the property of GILLAM-FEi. It is to be treated strictly confidential and is not to be disclosed, reproduced, or used except as authorized by GILLAM-FEi
HISTORY SHEET
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge 20/01/2012 Graphical User Interface
TABLE OF CONTENTS
1 Program installation ...............................................................................................1 1.1 Full installation on new platform...................................................................1 1.2 Upgrade current installation...........................................................................1
2 Startup of the Graphical User Interface .................................................................2 2.1 Configure COM1 (PC GUI)...........................................................................2 2.2 Open a user session (LOGIN)........................................................................6 2.3 Control of the IP parameters ........................................................................10 2.4 Connect through TCP-IP connection (TL1MNG) .......................................14 2.5 Controlling the features of the equipment ...................................................15 2.6 Output setup .................................................................................................16
2.6.1 NTP output card...................................................................................24 2.6.2 PTP output card....................................................................................25
2.7 Input configuration.......................................................................................26 2.8 Alarms viewing............................................................................................28 2.9 Log viewing .................................................................................................29 2.10 Create new user and his/her password .........................................................30 2.11 View or modify TL1 connection parameters ...............................................31 2.12 View or modify security parameters............................................................32 2.13 Runtime session timeout ..............................................................................33
3 GPS Local position setting...................................................................................34 4 Performance Monitoring......................................................................................36
4.1 Performance Monitoring in “Scheduled mode”...........................................36 4.2 Performance Monitoring in “Retrieve mode”..............................................38
4.2.1 FREQCORR ........................................................................................39 4.2.2 FFOFF, LMRTIE, MRTIE, TDEV......................................................40 4.2.3 TIE 1s...................................................................................................42
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 1/43 20/01/2012 Graphical User Interface
1 Program installation
1.1 Full installation on new platform 1. Execute the program HTBasic90rd.exe. This will install the run time environment
required by the GUI.
2. At the end of the HTBasic installation, restart the PC.
3. Execute setup_gui_12_7a.exe. This will install the GUI program. We recommend to use default installation setup (default installation on c:\us5g_gui).
4. For user convenience, create a program shortcut to 'US5G_GUI' on the PC desktop. To do this, just drag and drop the US5G_GUI icon from the C:\US5G_gui directory to the desktop.
Figure 1 : Copy of the property of the desktop shortcut.
1.2 Upgrade current installation To upgrade the GUI interface to a more recent version, just execute the setup program. For example : setup_gui_12_7a.exe.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 2/43 20/01/2012 Graphical User Interface
2 Startup of the Graphical User Interface
2.1 Configure COM1 (PC GUI) At first use the CRAFT port. Setup the port as shown hereafter (step 2 and next ones).
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 3/43 20/01/2012 Graphical User Interface
Step 2 : GUI COM Data setting
Note : The US5Ge / UNISYNCe equipments are setup by default to :
9600 bits/s, 8 data bits, 1 stop bit, no parity, no flow control.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 4/43 20/01/2012 Graphical User Interface
Step 3 : Establish the physical connection to the UNISYNCe US5Ge on CRAFT1 (straight cable) or CRAFT2 (crossed cable)
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 5/43 20/01/2012 Graphical User Interface
Step 4 : The physical connection is established
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 6/43 20/01/2012 Graphical User Interface
2.2 Open a user session (LOGIN)
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 7/43 20/01/2012 Graphical User Interface
After login on Craft port, the GUI must configure the US5Ge or the UNISYNCe to work in MMI mode without ECHO. These parameters are TL1 arguments named HMI=N, ECHO=N. The Craft connection will disconnect automatically. Wait for 3 seconds before entering again the CRAFT session. Perform again steps 2, 3, 4 and 5 to establish the connection with the GUI craft setup.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 8/43 20/01/2012 Graphical User Interface
The connection is finally established.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 9/43 20/01/2012 Graphical User Interface
Typical view of a connected US5Ge:
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 10/43 20/01/2012 Graphical User Interface
2.3 Control of the IP parameters
US5Ge : Click somewhere on the front panel of the COM card. UNISYNCe : Select in EQPT Menu : GPXM as below.
Setup accordingly with your network administrator the network parameters :
- DHCP mode, - IP, GATEW and SUBNET addresses.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 11/43 20/01/2012 Graphical User Interface
It is required to click on the EDIT button (toolbar menu) to initialize the corresponding parameters to the unit.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 12/43 20/01/2012 Graphical User Interface
The new network setting will be activated after the equipment has restarted its network interface. To do this, click on the “ETH-reset” button. Then click on OK button on the confirmation pop up windows to restart the equipment network interface.
The UNISYNCe closes all Ethernet connections.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 13/43 20/01/2012 Graphical User Interface
Reconnect to the unit after ETH-reset , either in CRAFT or in TL1MNG.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 14/43 20/01/2012 Graphical User Interface
2.4 Connect through TCP-IP connection (TL1MNG)
Choose the address or enter the address of the UNISYNCe - US5Ge to be polled.
LOGIN
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 15/43 20/01/2012 Graphical User Interface
2.5 Controlling the features of the equipment US5Ge : Click on the front view of the subassembly you want to control. UNISYNCe : Click on SSU from menu EQPT to open the different tables, or select unique object such as GPXM, INPUTs, or OUTPUTs.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 16/43 20/01/2012 Graphical User Interface
2.6 Output setup Type E1 configuration :
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 17/43 20/01/2012 Graphical User Interface
Output configuration : only "E1, S2048kHz, DLT" are valid.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 18/43 20/01/2012 Graphical User Interface
Alarm type selection for E1.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 19/43 20/01/2012 Graphical User Interface
Alarm type selection for 2048KHZ.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 20/43 20/01/2012 Graphical User Interface
Alarm mode for E1 outputs in case of E1MF type.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 21/43 20/01/2012 Graphical User Interface
Alarm mode for E1 outputs in case of E1SF type.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 22/43 20/01/2012 Graphical User Interface
Output enabling or disabling.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 23/43 20/01/2012 Graphical User Interface
Status and alarms refreshing Main outputs Main & Expansion
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 24/43 20/01/2012 Graphical User Interface
2.6.1 NTP output card Refer to US5Ge user guide & TL1 ref. manual for complementary data on NTP card provisioning and monitoring. UTC time Status of the Card 1 (left) Status of the Card 2 (right) source selection NTP name NTP server status LAN #1 (IP#1) Settings LAN #2 (IP#2) Settings Remote (backup) NTP server Network DNS
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 25/43 20/01/2012 Graphical User Interface
2.6.2 PTP output card Refer to US5Ge user guide & TL1 ref. manual for complementary data on PTP card provisioning and monitoring. PTP UTC time Card 1 (left) Card 2 (right) status source selection provisioning & provisioning & status status
PTP Setup Management (reserved) LAN interface: two cards PTP Clock network identification PTP Optical Interface IP setup
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 26/43 20/01/2012 Graphical User Interface
2.7 Input configuration
Modification of INPUT 1 SSM MODE
Menu EDIT
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 27/43 20/01/2012 Graphical User Interface
Access to GPS parameters:
Enter site position (press the [Enter] key and set the data) or Start a site survey (requires about 3 hours to be completed).
Setup other parameters: cable length (m), mask angle (°), …
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 28/43 20/01/2012 Graphical User Interface
2.8 Alarms viewing
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 29/43 20/01/2012 Graphical User Interface
2.9 Log viewing
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 30/43 20/01/2012 Graphical User Interface
2.10 Create new user and his/her password
1) Select in menu USER , USER-SECU 2) Window USER SECURITY
- UID : enter a new name - CID : define authorized accesses - UAP : define privileges
3) Window Enter new PASSWORD - *** : ENTER new password :minimum 5 characters
1 figure 1 sign (. + -)
- Select OK
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 31/43 20/01/2012 Graphical User Interface
2.11 View or modify TL1 connection parameters Select in menu CID, CID-DATA
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 32/43 20/01/2012 Graphical User Interface
2.12 View or modify security parameters Select in menu CID, CID-SECU
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 33/43 20/01/2012 Graphical User Interface
2.13 Runtime session timeout
After 50 minutes, following message is displayed. After that, you have to restart the GUI application and reconnect.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 34/43 20/01/2012 Graphical User Interface
3 GPS Local position setting The receiver current position is fixed by its antenna position. To work correctly, the UNISYNCe-US5Ge needs to know this position accurately. Once the GUI is started, we connect to the UNISYNCe-US5Ge and we log in the unit. On the main menu bar, we click on the EQPT button and we select INPuts/OSC item. A panel like this one below shows up:
We activate the GPS supervision windows by clicking on the GPS button (“GPS Monitoring” balloon here above).
GPS monitoring
Position to enter
manually
SET POS Visible
satellites Full GPS
initialization
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 35/43 20/01/2012 Graphical User Interface
Panel information summary: “Satellites infos” window This area shows up the data for the available satellites. “Current” window
This area shows up the local position and UTC time as determined by the receiver. Two coordinate representations are available 1) degree, minute, sec. 2) fractional degree.
“Position and parameter window”
This area shows up the parameters we can set up into the receiver. There are also two ways to represent the position coordinates.
“Factory Reset” button
This command asks the receiver to reset its memory backup. The memory is refreshed with working parameters and data as soon as they are updated by the receiver processor.
“Site Survey” button
Unfortunately, this command is not available within the GPS receiver. “Set POS” button
This command is used to set up the receiver coordinates from the data “Lat”, “Lon”, “Alt” defined on control left side.
“copy” button
This command is used to transfer the current local position determined by the receiver into the user parameter window.
“Refresh” check box
This command enables panel automatic refresh (every sec). Position setting :
• After having determined the geographical coordinates of the site, we set up the data on the left side of the “Position and parameter window”. We can use either coordinate representation to enter the data. The program updates automatically the second representation after we press ‘Enter” key.
• Click “Set POS” button to set up UNISYNCe-US5Ge parameter and to update GPS
receiver parameter.
• Check the “Current” window to see position update. Note: there is always a tiny little difference between data entered and data computed by the receiver.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 36/43 20/01/2012 Graphical User Interface
4 Performance Monitoring The Graphical User Interface of the UNISYNCe - US5Ge equipments can control the Performance Monitoring functions of the units. Because PM are managed in the same way on both equipments, the explanation and instruction described here apply to both. Note : PM functions are activated through TL1 command. So it is always possible to control
these functions directly from craft or telnet sessions. Performance Monitoring is accomplished in two different ways :
• On request of the operator and based on the “Retrieve mode” interface,
• Automatically with a programmable time interval and based on the “scheduled
mode” interface.
4.1 Performance Monitoring in “Scheduled mode” Once the GUI started, we connect to the UNISYNCe/US5Ge, and we login the unit. On the main menu bar we click on the SCHED button and we enter the TIE 1s Stripchart menu.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 37/43 20/01/2012 Graphical User Interface
A panel, like this one shows up:
On this panel, we dynamically follow up (every 10 s) the TIE for the activated input measure(s). See on the right size for input activation. It is possible to set up the data acquisition and its representation with the different buttons available on the screen.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 38/43 20/01/2012 Graphical User Interface
4.2 Performance Monitoring in “Retrieve mode” Once the GUI started, we connect to the UNISYNCe/US5Ge, and we login the unit. On the main menu bar we click on the PM button. It is possible to start collecting (retrieving) data memorized into the unit for the following parameters :
• FREQCORR : Follow up of the oscillator(s) control voltage,
• FFOFF : Frequency offset for the available inputs,
• LMRTIE: MRTIE computed on the fly,
• MRTIE: MRTIE computed on the accumulated TIE 1s data,
• TDEV: TDEV computed on the accumulated TIE 1s data,
• TIE 1s: TIE data acquisition with conversion to “.sqm” file format.
These measurements are associated with captured files stored into the PC hard disk (folder \US5G_GUI\measure).
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 39/43 20/01/2012 Graphical User Interface
4.2.1 FREQCORR A panel, like the one below, shows up:
After that, we have to specify the file for storage : accept the proposed file name, or enter your own one.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 40/43 20/01/2012 Graphical User Interface
The plot will look like the following one :
We can analyze the behavior of the oscillator(s) of the unit. Many controls help to manage the plots view.
4.2.2 FFOFF, LMRTIE, MRTIE, TDEV All these measures are used in the same way. A panel, like the one below, shows up:
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 41/43 20/01/2012 Graphical User Interface
After that, we have to specify the file for storage : accept the proposed file name, or enter your own one. The plot will look like the following one :
We can analyze the behavior of the measure for the selected input of the unit. Many controls help to manage the plots view. Note : It is possible to compare the measure with standard masks.
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 42/43 20/01/2012 Graphical User Interface
4.2.3 TIE 1s For this measure, there is no data representation available, because the data are saved on disk in a format fully compatible with SQM software. So for this measure, it is more easy and valuable to view and analyze it with our “SQM reader” available program.
After that, we have to specify the file for storage : accept the proposed file name, or enter your own one. The data acquisition (data retrieve), conversion and saving progress can be followed up on the next graph :
GILLAM – FEi
Doc ref. 4399MC-JMbf rev. 4 UNISYNCe US5Ge Page 43/43 20/01/2012 Graphical User Interface
With the SQM reader program, we get a plot like the following one :