4
1 Clients Doc. No. I-FD-5290.00-2311-941-HTP-011 Petrobras - Petróleo Brasileiro S.A. Refinaria do Nordeste - RNEST Hydrogen Generation Unit - U-35  No. 4309671 Rev. 0 Job S-01411 Page 1 of 4 Inf ormation contained herein is confidential and must not be used by or conveyed to any third party without our written authorisation - Haldor Topsøe A/S DK-2800 Lyngby, Denmark Job S-01411 WBS 44 Rev. Description Date Made by Chd. Appd. 0 First issue 19-FEB-2008 VIRP SKA SKA Specification for Chemicals

4309671 Specification for Chemicals Rev 0

  • Upload
    lilieq

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 4309671 Specification for Chemicals Rev 0

8/6/2019 4309671 Specification for Chemicals Rev 0

http://slidepdf.com/reader/full/4309671-specification-for-chemicals-rev-0 1/4

1

Clients Doc. No. I-FD-5290.00-2311-941-HTP-011

Petrobras - Petróleo Brasileiro S.A.

Refinaria do Nordeste - RNEST

Hydrogen Generation Unit - U-35

 No. 4309671 Rev. 0

Job S-01411

Page 1 of 4

Inf ormation contained herein is confidential and must not be used by or conveyed to any third party without our written authorisation - Haldor Topsøe A/S

DK-2800 Lyngby, Denmark 

Job S-01411 WBS 44

Rev.  Description Date Made by Chd. Appd.

0 First issue 19-FEB-2008 VIRP SKA SKA

Specification

for

Chemicals

Page 2: 4309671 Specification for Chemicals Rev 0

8/6/2019 4309671 Specification for Chemicals Rev 0

http://slidepdf.com/reader/full/4309671-specification-for-chemicals-rev-0 2/4

1

Clients Doc. No. I-FD-5290.00-2311-941-HTP-011

Petrobras - Petróleo Brasileiro S.A.

Refinaria do Nordeste - RNEST

Hydrogen Generation Unit - U-35

 No. 4309671 Rev. 0

Job S-01411

Page 2 of 4

Inf ormation contained herein is confidential and must not be used by or conveyed to any third party without our written authorisation - Haldor Topsøe A/S

DK-2800 Lyngby, Denmark 

1.  General Information

This specification covers the chemicals required within the HTAS battery limit of thehydrogen plant.

2.  Chemicals for BFW Preparation

2.1  Phosphate

Quality Commercial grade crystallised Na3PO4 * 12H2O suitable for boiler 

feed water conditioning. Sample and certified specification to be

submitted to the boiler vendors for approval. The chemical mustnot contain any sulphur or chlorine compounds.

Consumption Approximately 500 kg/year 

2.2  Morpholine

Quality Commercial grade morpholine (tetrahydro-1,4 isoxazine) suitable

for boiler feed water conditioning. Sample and certified

specification to be submitted to the boiler vendors for approval.

The morpholine must not contain any sulphur or chlorine

compounds.

Consumption Approximately 25500 kg/year 

3.  Chemicals for HDS Section

3.1  DMDS

Quality Commercial grade DMDS, max. 1% DMS

Consumption

Start-up (presulphiding new catalyst) 900 kg

  Normal operation, max. 950 kg/year 

Page 3: 4309671 Specification for Chemicals Rev 0

8/6/2019 4309671 Specification for Chemicals Rev 0

http://slidepdf.com/reader/full/4309671-specification-for-chemicals-rev-0 3/4

1

Clients Doc. No. I-FD-5290.00-2311-941-HTP-011

Petrobras - Petróleo Brasileiro S.A.

Refinaria do Nordeste - RNEST

Hydrogen Generation Unit - U-35

 No. 4309671 Rev. 0

Job S-01411

Page 3 of 4

Inf ormation contained herein is confidential and must not be used by or conveyed to any third party without our written authorisation - Haldor Topsøe A/S

DK-2800 Lyngby, Denmark 

3.2  Methanol

Quality: as per IMPCA’s specification

Appearance Clear and free of suspended matter 

Purity % WT on dry basis Min. 99.85

Acetone mg/kg Max. 30

Colour PT-CO Max. 5

Water % W/W Max. 0.1

Distillation range at 760 mm Hg Max. 1,0° C to include 64,6° ± 0,1°

Specific gravity 20°/20° 0.791-0.793

Potassium permanganate

Time test at 15° C, minutesMin. 60

Ethanol mg/kg Max. 50

Chloride as Cl - mg/kg Max. 0.5

Sulphur mg/kg Max. 0.5

Hydrocarbons pass test

Carbonisable Substances

(Sulfuric Acid Wash Test)

Ot-Co Scale

Max. 30

Acidity as

Acetic acidmg/kg Max. 30

Total iron mg/kg Max. 0.1

  Non volatile matter mg/1000 ml Max. 8

Consumption per:

Start-up (normal startup) 2200 kg

Start-up (with TK-250 presulphiding) 14000 kg

Shut-down 550 kg

Page 4: 4309671 Specification for Chemicals Rev 0

8/6/2019 4309671 Specification for Chemicals Rev 0

http://slidepdf.com/reader/full/4309671-specification-for-chemicals-rev-0 4/4

1

Clients Doc. No. I-FD-5290.00-2311-941-HTP-011

Petrobras - Petróleo Brasileiro S.A.

Refinaria do Nordeste - RNEST

Hydrogen Generation Unit - U-35

 No. 4309671 Rev. 0

Job S-01411

Page 4 of 4

Inf ormation contained herein is confidential and must not be used by or conveyed to any third party without our written authorisation - Haldor Topsøe A/S

DK-2800 Lyngby, Denmark 

4.  Safety Instructions

The vendors of chemicals are to supply toxicological information and instructions

regarding safe handling and proper storage of the pure chemicals.