Air curtains type www.stavoklima.eu Contents: •banks and hotels •offices and commercial buildings •industrial applications •trade-fair halls, convention or exhibition centres and supermarkets. As a separating medium •to circulate air of room temperature •to circulate heated air •to restrict the ingress of air into a building Air curtains type „ Li “
Citation preview
01/09 TechnicalModificationsreserved page3
Selecting an air curtain .................................................................................................................page 4
Technical data - dimensions „Li“ ...............................................................................................page 5
Technical data - capacity .......................................................................................................... page 6-7
Underview air curtains .............................................................................................................. page 7-8
Accessories for the air curtains .............................................................................................page 9-10
Operating the air curtains.................................................................................................... page 11-13
Air curtain types ............................................................................................................................page 14
Overview of all air curtains ........................................................................................................page 15
Order key .........................................................................................................................................page 16
Model „Li“
Contents:
Air curtains type „Li“
Air curtains are preferably designatedfor use in:
•banks and hotels•offices and commercial buildings•industrial applications• trade-fair halls, convention
or exhibition centres and supermarkets.
As a separating medium
•to circulate air of room temperature•to circulate heated air•to restrict the ingress of air into a building
Y
X
X
Y
�t
�p
+18°C
-15°C
v (m/s)
I. II. III.
page4 TechnicalModificationsreserved 01/09
Assembly: vertical / horizontalTypes: cold air / hot air
(hot water, electrical or steam heated)for door heights of: 2,2; 2,5; 2,8; 3,5mfor door widths of: 1,0; 1,5; 2,0; 2,5m with connection
piece for any door widthColour: Standard RAL 9010 (white), optional: all
RAL- colours
The Li range suitable for use in interior areas,where substantial demands in design are required.The Li range is supplied with EU2 grade air filtersto ensure air quality (hot water units only).
Pay special attention when planning air curtains:
air velocity in theaperture in (m/s)
Simple Installation:One doorway with
vestibule (if applicable).Light winds.
Medium Installation:Multiple doorwayswithout vestibules.
Medium winds.
Complex Installation:Multiple doorways with vestibules.
Open stories. Strong winds.• Negative pressure conditions.
Installations
Air curtains type„Li“Selecting an air curtain
air curtain widthaperture width
air curtainassembly height
differential temperature andpressure between indoor
and outdoor spaces
∆t
∆p
M10
f
D
n
me
o
j'p
cj
n
k l kl
a V
G 3/4" -G 5/4"
H
Technical data - dimensions „L i“
construction withthermostatic valve
electrically heatedheater in rightside furnishing(according to unit type)
air inlet
Model THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- Lix Lix Lix Lix Li0 Li0 Li0 Li0 Li1 Li1 Li1 Li1 Li2 Li2 Li2 Li2
Air outlet aperture height [m] 2,2 2,2 2,2 2,2 2,5 2,5 2,5 2,5 2,8 2,8 2,8 2,8 3,5 3,5 3,5 3,5
Dimensions length D [mm] 1000 1500 2000 2470 1000 1500 2000 2470 1000 1500 2000 2470 1000 1500 2000 2470
of the unit height V [mm] 335 335 335 335 335 335 335 335 335 335 335 335 380 380 380 380
depth H [mm] 615 615 615 615 615 615 615 615 615 615 615 615 655 655 655 655
Dimensions width a [mm] 278 278 278 278 278 278 278 278 278 278 278 278 323 323 323 323
of the air inlet grille length b [mm] D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50
Dimensions width c [mm] 80 80 80 80 80 80 80 80 80 80 80 80 100 100 100 100
of the air outlet grille length d [mm] D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50 D-50
Assembly m [mm] 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5 47,5
n [mm] 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5
o [mm] 75 75 75 75 75 75 75 75 75 75 75 75 80 80 80 80
e [mm] 494 494 494 494 494 494 494 494 494 494 494 494 530 530 530 530
f [mm] 975 1475 1975 2445 975 1475 975 2445 975 1475 1975 2445 975 1475 1975 2445
Connections k [mm] 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5 61,5
l [mm] 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
p [mm] 103 103 103 103 103 103 103 103 103 103 103 103 108 108 108 108
j [mm] 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26
j’ [mm] 216 216 216 216 216 216 216 216 216 216 216 216 216 216 216 216
01/09 TechnicalModificationsreserved page5
Air curtains type „Li“
Technical data THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- Lix Lix Lix Lix Li0 Li0 Li0 Li0 Li1 Li1 Li1 Li1 Li2 Li2 Li2 Li2 N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E) N(E)
Air- handling capacity [m3/h] 1600 2400 3400 4200 2000 3200 4300 5600 2300 3700 5150 6300 3700 5400 8100 9500 Hot water heater (water 80/60°C) i=18°C capacity** [kW] 11,6 19,1 28,2 35,4 13,1 22,5 32,3 41,8 14,2 24,4 35,8 44,6 20,0 34,1 49,8 61,6 pressure loss [kPa] 5,3 3,8 9,9 7,5 6,6 5,1 12,6 10, 17,6 5,9 15,1 11,3 3,6 8,3 5,9 6,7 flow volume rate [m3/h] 0,47 0,79 1,20 1,51 0,54 0,94 1,37 1,76 0,58 1,04 1,51 1,91 0,83 1,44 2,12 2,26 Hot water heater (water 60/40°C)* i=18°C capacity** [kW] 6,4 10,8 16,3 20,4 7,3 12,6 18,6 23,9 7,8 13,6 20,5 25,5 10,7 19,1 27,6 34,4 pressure loss [kPa] 2,00 1,40 3,90 3,00 2,40 1,90 5,00 3,90 2,80 2,20 5,95 4,40 1,20 3,10 2,20 2,50 flow volume rate [m3/h] 0,25 0,43 0,68 0,86 0,29 0,54 0,79 1,00 0,32 0,58 0,86 1,08 0,43 0,79 1,15 1,47 Connection [DN] 20 20 20 20 20 20 20 20 20 20 20 20 20 20 25 32Electric heater** capacity alt1 Max.[kW] 3,0 6,0 12,0 12,0 3,0 6,0 12,0 15,0 3,0 6,0 15,01 18,0 3,0 6,0 15,0 21,0 capacity alt 2 Max.[kW] 6,0 9,0 15,0 15,0 6,0 9,0 15,0 18,0 6,0 9,0 18,0 24,0 6,0 9,0 18,0 27,0 capacity alt 3 Max.[kW] 6,0 9,0 15,0 15,0 6,0 9,0 15,0 18,0 6,0 9,0 18,0 24,0 9,0 12,0 21,0 30,0 capacity alt 4 Max.[kW] - - - 21,0 12,0 15,0 21,0 24,0 12,0 15,0 24,0 30,0 12,0 15,0 24,0 36,0 power supply*** [V] 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 sections [number] 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3Fan fan power input [W] 90 184 180 274 147 298 298 445 147 298 298 445 420 617 840 1037 fan current [A] 0,8 1,6 1,6 2,4 1,5 3,0 3,0 4,5 1,5 3,0 3,0 4,5 3,7 5,2 7,4 8,9 fan voltage [V] 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230Control type cold, hot water heated air curtainControl type electrically heated air curtain Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20Noise level dB (A) 52 53 55 56 55 58 61 63 59 62 62 65 61 63 65 66Weight [kg] 35 52 88 95 42 65 97 106 45 68 100 110 58 74 114 132
ECON, DITRONIC (PLUS)
DITRONIC (PLUS)
*) For low water-temperature gradients 60/40, 60/30... it is possible to deliver a style „NN“ coil with higher capacity see page 7**) Heaters with modified or higher capacities are available on request***) Electric heaters with voltage 3x 230 V are available on request
EU2 grade air filter is installed withhot water air curtains. Moveable blades for
optimal performance.
High capacity fans withinbuilt overloadprotection.
Technical data
page6 TechnicalModificationsreserved 01/09
The inlet grille allows easy service accessto the unit and an additional designfeature that may enhancean internal space.
Air curtains type„Li“
DM
Alt „A“ Alt „B“
Technical data THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- 100-3- 150-3- 200-3- 250-3- Lix Lix Lix Lix Li0 Li0 Li0 Li0 Li1 Li1 Li1 Li1 Li2 Li2 Li2 Li2 NN NN) NN NN NN) NN NN NN NN NN NN NN NN NN NN NN
Air- handling capacity [m3/h] 1600 2200 3300 4000 2100 3100 4400 5700 2300 3700 5200 6700 3300 5000 7900 9000
Hot water heater (water 70/50°C)
i=18°C capacity** [kW] 14,2 19,2 28,3 35,1 15,4 25,8 37,1 47,6 16,3 28,7 41,1 52,6 22,5 37,9 58,2 69,2
pressure loss [kPa] 8,9 8,2 7,4 6,3 4,7 9,5 9,8 7,5 5,2 11,6 11,9 8,9 6,5 10,0 11,1 8,2 flow volume rate [m3/h] 0,57 0,79 1,18 1,47 0,64 1,08 1,58 2,01 0,68 1,22 1,76 2,23 0,93 1,62 2,48 2,95
Hot water heater (water 60/40°C)
i=15°C capacity** [kW] 11,4 15,6 23,0 28,5 12,3 20,9 31,0 38,6 13,0 23,3 33,4 42,6 18,0 30,7 47,1 55,9
pressure loss [kPa] 6,3 5,9 5,3 4,5 3,2 6,8 18,1 5,3 3,6 8,3 5,5 6,3 4,5 7,1 7,9 5,8 flow volume rate [m3/h] 0,46 0,64 0,97 1,19 0,50 0,86 1,33 1,65 0,54 0,97 1,40 1,80 0,75 1,29 2,01 2,37
Connection [DN] 20 20 20 20 20 20 20 20 20 20 20 20 20 20 25 32
Fan
fan power input [W] 90 184 184 274 147 298 298 445 420 570 840 840 420 617 840 1037
fan current [A] 0,8 1,6 1,6 2,4 1,5 3,0 3,0 4,5 3,7 5,2 7,4 7,4 3,7 5,2 7,4 8,9
fan voltage [V] 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230
Control type
cold, hot water heated air curtain
Control typeelectrically heated air curtain
Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20
Noise level dB (A) 52 53 55 56 55 58 61 63 59 62 62 65 61 63 65 66
Weight [kg] 35 52 88 95 42 65 97 106 45 68 100 110 58 74 114 132
ECON, DITRONIC (PLUS)
DITRONIC (PLUS)
Unit design „180°“
Technical data for water heated coils NN
01/09 TechnicalModificationsreserved page7
Air curtains type „Li“
1
2
3
4
5
D
Lix,Li0,Li1=80Li2=100Li3=140
min.100max.150*
Lix,Li0,Li1=470Li2=490Li3=570
Lix,Li0,Li1 = 960Li2 = 995Li3 = 1275
Lix,Li0=300Li1,Li2=300
Li3=450
M
A
B
Frame for unit mounting „180°“
Underview air curtains
page8 TechnicalModificationsreserved 01/09
Air curtains type„Li“
You will find the dimensions and technical data for Li3 in the catalogue „Li3“, „Li4“.
40
30
20
0,2
0,3
0,5
1
2
3
5
10
20
30
0,150 100 200 300 500 1000 2000 3000
DN 25 (1")DN 32 (11/4") DN 25 XXL (1")
The frames for underview Li air curtains are anodised or finished in RAL-9010 white as standard.All RAL colours can be supplied as non-standard finishes.
Suspension of theair curtains as anunderview unit
Suspensiontype A
Medium connections for the underview air curtains The air curtains can also be connected laterally - please specify when ordering.
connectionslateral
connectionsupper
see dimensions p.5
dtto
dimensionson demand
2-way valveThe unit can be suppliedwith an inbuilt 2-way valvewith thermostatic actuators(range 20-50°C). Thebody of this valve iscorrosion-proof bronze.The valve offers smallhydraulic resistance.The complete top partof the valve is exchangeableonce the unit is installed.Max. temperature 120°C.
Flow quantity [kg/h]
Pres
sure
loss
∆p
[kP
a]
kv“** permitted permitted permitted2-way valve value working temp. working pressure difference pressure [°C] [bar] p [bar]
DN 25 (1“) 2,5 120 10 0,25
DN 32 (5/4“) 3,8 120 10 0,25
DN 25 XXL (1“) 4,3 120 16 0,20
* high flow valve** for DN25, 32 is valid for [K] 3.0; for DN25, XXL is valid for [K] 6.0
01/09 TechnicalModificationsreserved page9
Controls for the air curtains
Air curtains type „Li“
50
0,2
0,3
0,5
1
2
3
5
10
20
30
0,1100 200 300 500 1000 2000 3000 4000 5000
500
300
200
100
50
30
20
10
5
3
2
1 10
20
30
50
100
200
300
500
1000
2000
3000
5000
DN 25 (kvs 4,6)
DN 32 (kvs 6,4)
DN 32 XXL (kvs 10,0)
DN 40 XXL (kvs 12,0)
3-way valveThe unit can be supplied with a 3-way valve with thermostator electrothermic actuators (range 20- 50°C).
While switching the 3-way valve there are caused no pressure impacts in the system and the valve can be operated also in inter-positions.
A capillary sensor is installed behind the heat exchanger to regulate outlet air temperature.
Thermostatic head for2-way or 3-way valve
The unit can be supplied witha 2-way or 3-way valve withthermostatic actuator (range20-50°C). A capillary sensor isinstalled behind the heatexchanger to regulate outlet airtemperature.
Electrothermic gear for2-way or 3-way valve
The unit can be supplied with a 2-wayor 3-way thermoelectric valve. Whenthe thermo gear is under voltage,a built-in sensor is warming up, aftertime differential has lapsed, the gearstarts to close continuously. Voltageinterruption causes a continuous openingof thermo gear.
Electro data: 230V/50Hz, 3Ph, IP 42
kv“** permitted permitted permitted3-way valve value working temp. working pressure difference pressure [°C] [bar] p [bar]
DN 25 (1“) 4,6 100 10 0,50
DN 32 (5/4“) 6,4 100 10 0,25
DN 32 XXL (5/4“)* 10,0 120 10 0,20
DN 40 XXL (2“)* 12,0 120 10 0,20
* only with electrothermic gear
Flow quantity [kg/h]
Pres
sure
loss
∆p
[kP
a]
Pres
sure
loss
∆p
[m
m v
.sl.]
Pres
sure
loss
∆p
[m
bar
]
Accessories to the air curtains
page10 TechnicalModificationsreserved 01/09
Air curtains type„Li“
‰hl.
v
‰hl.
v
L
L1
NFA1
dveřní kontakt
PE
ovládání ECON
Teplovodní clony - schéma
10 x 1
externí kontakt,termostat
externí kontakt,termostat
2 x 13x2,5
L3
L2
N FA3FA1
FA2PE
L1
ovládání ECON
WL3WL2
WL1
10 x 1
Elektro clony - schéma
dveřní kontakt
2 x 1
CONTROL TYPE WATER HEATED AIR CURTAINS ELECTRIC AIR CURTAINS
Econ for all types not possible to deliverDITRONIC (PLUS) for all types for all types
Control for water heated and electro units DITRONIC (PLUS)
Control description:Regulator Ditronic is a processor regulator of new generation,equiped with lots of additional functions in standardequipment. Because of its design and big blue display itis suitable for all kinds of interiors (from basic to the comfortones). The control is equiped with several levels, from basicone, for easy control to user settings on customer wish. Itis also possible to configurate the control via PC and USBport (Ditronic plus).
Dimensions:DITRONIC – w. 148 x h. 80 x d. 33 [mm]DITRONIC PLUS – w. 148 x h. 80 x d. 33 [mm]
Table of controls for hot water* or electro models „Li“
The control is intended for wall mounting IP 20. Controlconnection via cable with pressedconnector RJ 45 see pic.
01/09 TechnicalModificationsreserved page11
Functions of Econ control:
Control: Econ
Control description: Econ is intended for fan and heater (water heated or ambient) control, with connection possibility of external elements (door contact, room or outlet thermostat)
Dimensions w. 71 x h. 71 x d. 25 [mm]The control is intended only for wall mounting. IP 20
Free potential door contact incl. time delay
standard Small control dimensions, wall mounting
standard
Connection in Master/Slave not possiblePossibility of electrothermic valve control
standard
Room thermostat, control via external remote contact
standard
* valid also for ambient air curtains
DITRONIC
Ovládání vzduchových dveřních clon
strana 1102/07 Te c h n i c k é z m ě n y v y h r a z e n y
Vzduchové dveřní clony komfortní „Li“
Rozdělení ovladačů pro teplovodní* a elektrické clony
Ovládání LS99, LS02, LS03
TYP OVLÁDÁNÍ TEPLOVODNÍ CLONY ELEKTRICKÉ CLONYLS 99 pro clony Li0-2-100, Lix-100-150 nedodává seLS 02 pro clony Li0-2-150-200, Lix-250 nedodává seLS 03 pro clony Li0-2-250 nedodává seDITRONIC PLUS pro v‰echny modely pro v‰echny modely
Popis ovládání:Ovladače jsou určeny pro regulaci otáček bez možnosti připojení externích ovlá-dácích prvků (dveřní kontakt, termostat).U těchto ovladačů nelze provést zapojenísystémem Master/Slave.
Propojovací kabel:LS 99 – 7x 1,5•
LS 02 – 12x 1,5•
LS 03 – 12x 1,5•
Rozměry:LS 99 – š. 94 x v. 65 x hl. 81 [mm]LS 02 – š. 110 x v. 110 x hl. 90 [mm]LS 03 – š. 180 x v. 110 x hl. 111 [mm]
Ovladač je určen pro: povrchovou nebo polozapuštěnou montáž.
Ovládání pro teplovodní a elektrické clony Ditronic (PLUS)Popis ovládání:Ovladač Ditronic je procesorový regulátor zcela nové řadyvybavený mnoha doplňkovými funkcemi ve standardní vý-bavě. Regulátor svým designem a velkým displayem modrébarvy je vhodný pro všechny druhy provozů (od základníchaž po komfortní interiéry). Ovladač je vybaven několika úrovniovládání od základního, pro jednoduché ovládání až po uži-vatelské nastavení na přání zákazníka. Též je možno ovladačkonfigurovat prostřednistvím PC přes USB port (Ditronic plus).
Rozměry:DITRONIC– š. 148 x v. 80 x hl. 33 [mm]DITRONIC PLUS– š. 148 x v. 80 x hl. 33 [mm]
Ovladač je určen pro nástěnnoumontáž IP20. Zapojení ovladačeprostřednictvím kabelu s nalisova-ným konektorem RJ45 viz obr.
* platí i pro studené clony
LS02
DITRONIC
‰hl.
v
‰hl.
v
L
propojovacíkabel ovládání
ovládání LS
napájecí kabel3C x 1,5 (2,5)
v
šhl.Tablet of cables and protection
FA1 1 X 10A/C WL1 3Cx 1,5 (2,5)
FA2 viz. tab. EO WL2 viz. tab. EO
FA3 viz. tab. EO WL3 viz. tab. EO
ECON
Air curtains type „Li“Controls for the air curtains
Water heated aur curtains – Scheme
Control ECON
Door contact
External contact, thermostat
h
wd
kW
Week time clockThe unit can be operated according to the weekregime. You can choose the regime 1-7 or 1-5; 6-7.
Anti-frost protection of the heat exchangerFor each water heated unit is standard an inbuiltanti-frost protection. It is a protection in 2 grades.When there is a danger of freezing the valveopens and switch the signalling contact.
Anti-frost protection of the roomThe control allows via room sensorwatch the anti-frost protectionof the room at the same time.
Setting of the valve switching curveAccording to the request and medium qualityyou can correct the switching sequencesof the electrothermic valve.
Indication of the roomand outlet temperatureThe regulator shows the room, outlet andalso required temperature as standard
Door contactThe unit can be operated from the door contact.After the door will close, time delay isactivated and this is adjustable.
Keyboard lockBecause of undesirable setting changesof the control, you can lock the keyboard.
Unit control according tothe outlet or room temperatureThe system allows to control the temperatureaccording to the room or outlet air temperature.There is an inbuilt function to restrict the min.outlet temperature at the same time.
Superior system– BMS 3-gradesThe whole unit can be operated from the superiorregulation systems. 3-grades control of the heaterand also the fan is inbuilt in standard. At thiskind of control the unit is completely controledfrom BMS (building management system).
Failure and operatingoutlet of the unitFrom the unit electronics are taken outthe failure and operating contacts for signalling.
Processor unit controlof the electro heaterElectro heater is operated via processor with interactivelogic, which prevents from heater overheating.
Indication of the topicalmedium temperatureThe regulator shows at the water heatedtypes the inlet medium temperature.
Configuration via USB interfaceSetting of the regulation functions can bemade on a PC via USB port (possible onlyat Ditronic plus).
Restrictive exterior thermostatVia restrictive thermostat (mostly used in theexterior) after achieving the setted temperatureit is possible to switch off only the heating orthe whole unit (according setting on the control).
MASTER/SLAVESerial equipment is possibility to connect allmodels in the system MASTER/SLAVE. The roomsensor is used only with the unit MASTER.
External contactYou can run the unit also from other distantexternal place. Usage of this contact eliminatesusing the wireless radio control and reverse.
Automatic running of the unitThe unit can run in the automatic regime fromthe door contact. When the door is closed,the unit runs on the 1.grade of heating and fan.After the door opens, the unit runs inthe setted grades on the control.
Heat up regimeFor the case, that it will be necessary to covercasual heating losses you can activate the unitfor selected time in the heat up regime,so the unit will achieve the biggest heatingcapacity in the shortest time period.
BMS 0-10VTo control from BMS 0-10Vit is necessary to order a modulefor control linked with the signal 0-10V.
Radio controlYou can run the unit also via wireless control.For this choice it is necessary to ordera receiver, which is inbuilt in the unit.
Additional modules for the control Ditronic
Description of standard functions at the controls DITRONIC (DITRONIC PLUS)for water heated and electro units.
Controls for the air curtains
page12 TechnicalModificationsreserved 01/09
Air curtains type„Li“
WS7
WS8
WS10
WS6
WS1
– –
– –
– –
L3
L2
N FA3FA1
FA2
WL3WL1
WL2
FA3FA1
FA2
WL3WL1
WL2
WS5WS4
WS2
L1
NFA1
WL1
FA1
WL1
WS5WS4
WS7
WS8
WS10
WS6
WS9 WS11WS12
PE
L1
Master
Slave
WS9 WS11WS12
PE
Master
Slave
WS1WS2
electro heater cabel (WL2) circuit breaker (FA2) cabel (WL3) circuit breaker (FA3) electro heater cabel (WL2) circuit breaker (FA2) cabel (WL3) circuit breaker (FA3)
FA1 1 x 16A/C WL2 viz. tab.EO WS3 4 x 2 x 0,5 WS7 2A x 1(1,5) WS11 2A x 1(1,5)
FA2 viz. tab.EO WL3 viz. tab.EO WS4 5D x 1(1,5) WS8 2A x 1(1,5) WS12 2D x 1(1,5)
FA3 viz. tab.EO WS1 4 x 2 x 0,5 WS5 5D x 1(1,5) WS9 5D x 1(1,5) WS13 4 x 2 x 0,5
WL1 3C x 1,5(2,5) WS2 4 x 2 x 0,5 WS6 2A x 1(1,5) WS10 2A x 1(1,5)
6 kW 3A x 4 3 x 16A/B 4B x 4 3 x 16A/B 24 kW 3A x 4 3 x 16A/B 4B x 6 3 x 32A/B
9 kW 3A x 4 3 x 16A/B 4B x 4 3 x 16A/B 27 kW 3A x 4 3 x 16A/B 4B x 6 3 x 32A/B
12 kW 3A x 4 3 x 16A/B 4B x 4 3 x 16A/B 30 kW 3A x 4 3 x 25A/B 4B x 6 3 x 32A/B
15 kW 3A x 4 3 x 16A/B 4B x 4 3 x 16A/B 33 kW 3A x 4 3 x 25A/B 4B x 6 3 x 40A/B
18 kW 3A x 4 3 x 16A/B 4B x 4 3 x 25A/B 36 kW 3A x 4 3 x 25A/B 4B x 10 3 x 50A/B
21 kW 3A x 4 3 x 16A/B 4B x 4 3 x 25A/B 39 kW 3A x 4 3 x 25A/B 4B x 10 3 x 50A/B
Tablet of cables and protection
Tablet of electro heater (EO)
Failure
output
Operating
output
fan heatingheating
fan
Control DITRONIC
Tablet of cables and protection for water heated* air curtains
Electro air curtains – Scheme
* valid also for ambient air curtains
outside restrictive thermostat
room sensor
external contact
door contact
Failure
output
Operating
output
fan heatingheating
fan
Control DITRONIC
Water heated air curtains – Scheme
Controls for the air curtains
FA1 1 x 10A/C WS1 4 x 2 x 0,5 WS5 5D x 1(1,5) WS9 5D x 1(1,5) WS13 4 x 2 x 0,5
FA2 1 x 10A/C WS2 4 x 2 x 0,5 WS6 2A x 1(1,5) WS10 2A x 1(1,5) WS14 2D x 1(1,5)
FA3 1 x 10A/C WS3 4 x 2 x 0,5 WS7 2A x 1(1,5) WS11 2A x 1(1,5)
WL1 3C x 1,5(2,5) WS4 5D x 1(1,5) WS8 2A x 1(1,5) WS12 2D x 1(1,5)
01/09 TechnicalModificationsreserved page13
outside restrictive thermostat
room sensor
external contact
door contact
Air curtains type „Li“
Master
02/07Te c h n i c k é z m ě n y v y h r a z e n y
provedení „HC“ „XX0“(viz označení délky v klíči
(strana 16)
provedení „HC“ „XX9“(viz označení délky v klíči
(strana 16)
provedení „VC“ „XX0“(viz označení délky v klíči
(strana 16)
provedení „VC“ „XX9“(viz označení délky v klíči
(strana 16)
Air curtain connections „Li“
Air curtains type „Li“ - „0°“ nebo „90°“
connection kit SPS
Type „HC“ „XX0“(For dimensions see order key,
page 16)
Type „HC“ „XX9“(For dimensions see order key,
page 16)
Type „VC“ „XX0“(For dimensions see order key,
page 16)
Type „VC“ „XX9“(For dimensions see order key,
page 16)
Types of air curtains
page14 TechnicalModificationsreserved 01/09
Air curtains type„Li“
Overview of all air curtains
Industrial
Comfort
Design
Li3, Li4Axi
Li
Arcus
Compact
Arcus-X
Magnum
Nucleo
01/09 TechnicalModificationsreserved page15
Lix N - capacity level 1; standard heater; recommended mounting height 2,2mLi0 N - capacity level 2; standard heater; recommended mounting height 2,5mLi1 N - capacity level 3; standard heater; recommended mounting height 2,8 mLi2 N - capacity level 4; standard heater; recommended mounting height 3,5mLix NN - capacity level 1; heater for low-temperature gradients;
recommended mounting height 2,2mLi0 NN - capacity level 2; heater for low-temperature gradients;
recommended mounting height 2,5mLi1 NN - capacity level 3; heater for low-temperature gradients;
recommended mounting height 2,8mLi2 NN - capacity level 4; heater for low-temperature gradients;
recommended mounting height 3,5mLix E - capacity level 1; electric heater; recommended mounting height 2,2mLi0 E - capacity level 2; electric heater; recommended mounting height 2,5mLi1 E - capacity level 3; electric heater; recommended mounting height 2,8mLi2 E - capacity level 4; electric heater; recommended mounting height 3,5 m
3 - enginerevolution 0 -3 (standard type „3“)
100, 109 - air curtain length 1000mm150, 159 - air curtain length 1500mm200, 209 - air curtain length 2000mm250, 259 - air curtain length 2500mm300, 309 - standard length,
(150 + 150)(XX0, XX9 - see air curtain types page 14)
P - right-side furnishing of the heater (suction side view)
L - left-side furnishing of the heater (suction side view)
VC - vertical air curtainHC - horizontal air curtain
S - cold air typeT - hot air type (hot water heater,
electric heater)(on demand other heater types are possible - steam...)
T - HC - P - 100 - 3 - Li 1N
Typ
e
Air
cu
rtai
nas
sem
bly
Hea
ter
typ
e
Air
cu
rtai
nle
ng
th
Air
curt
ain
type
s
Engi
ne ty
pe
Order key:
Accessories:
Further atypical types:
•Thermostatic valve with capillary sensor
•Accessories for underview air curtains
•Ceiling-suspended base
•Wall-suspended base
•Operating device
•Door contact
• With outside air admixture
cold winter air heated air
odour, dust filtered air
hot summer air cooled air
Air cu
rtains typ
e „Li“
ENG
Li 0
1/0
9