59
4.0 CORROSION PREVENTION MATERIAL SELECTION ALTERATION OF ENVIRONMENT PROPER DESIGN CATHODIC PROTECTION ANODIC PROTECTION COATINGS & WRAPPING

4.0 CORROSION PREVENTION

Embed Size (px)

DESCRIPTION

4.0 CORROSION PREVENTION. MATERIAL SELECTION ALTERATION OF ENVIRONMENT PROPER DESIGN CATHODIC PROTECTION ANODIC PROTECTION COATINGS & WRAPPING. (1) MATERIAL SELECTION (selection of proper material for a particular corrosive service). Metallic [metal and alloy] - PowerPoint PPT Presentation

Citation preview

Page 1: 4.0 CORROSION PREVENTION

4.0 CORROSION PREVENTION

MATERIAL SELECTIONALTERATION OF ENVIRONMENT

PROPER DESIGNCATHODIC PROTECTION

ANODIC PROTECTION COATINGS & WRAPPING

Page 2: 4.0 CORROSION PREVENTION

(1) MATERIAL SELECTION (selection of proper material for a

particular corrosive service)

Metallic [metal and alloy]Nonmetallic [rubbers (natural and synthetic), plastics, ceramics, carbon and graphite, and wood]

Page 3: 4.0 CORROSION PREVENTION

Metals and Alloys

No Environment Proper material1 Nitric acid Stainless steels2 Caustic Nickel and nickel

alloys3 Hydrofluoric acid Monel (Ni-Cu)4 Hot hydrochloric

acidHastelloys (Ni-Cr-Mo) (Chlorimets)

5 Dilute sulfuric acid Lead

Page 4: 4.0 CORROSION PREVENTION

No Environment Proper material6 Nonstaining

atmospheric exposure

Aluminium

7 Distilled water Tin8 Hot strong oxidizing

solutionTitanium

9 Ultimate resistance Tantalum10 Concentrated

sulfuric acidSteel

Page 5: 4.0 CORROSION PREVENTION

E.g : Stainless Steels

Stainless steels are iron base alloys that contain a minimum of approximately 11% Cr, the amount needed to prevent the formation of rust in unpolluted atmosphere.

wt.% Cr

Dis

solu

tion

rate

, cm

/sec

Page 6: 4.0 CORROSION PREVENTION

Alloying elements of stainless steel : Other than Ni, Cr and C, the following alloying

elements may also present in stainless steel: Mo, N, Si, Mn, Cu, Ti, Nb, Ta and/or W.

Main alloying elements (Cr, Ni and C):

1. Chromium Minimum concentration of Cr in a stainless steel is 12-14wt.% Structure : BCC (ferrite forming element)

* Note that the affinity of Cr to form Cr-carbides is very

high. Chromium carbide formation along grain boundaries may induce intergranular corrosion.

Page 7: 4.0 CORROSION PREVENTION

Binary diagram of Fe-Cr

Sigma phase formation which is initially formed at grain boundaries has to be avoided because it will increase hardness, decrease ductility and notch toughness as well as reduce corrosion resistance.

Page 8: 4.0 CORROSION PREVENTION

2. Nickel

Structure: FCC (austenite forming element/stabilize austenitic structure)

Added to produce austenitic or duplex stainless steels. These materials possess excellent ductility, formability and toughness as well as weld-ability.

Nickel improves mechanical properties of stainless steels servicing at high temperatures.

Nickel increases aqueous corrosion resistance of materials.

Page 9: 4.0 CORROSION PREVENTION

Ternary diagram of Fe-Cr-Ni at 6500 and 10000C

AISI : American Iron and Steel Institute

Page 10: 4.0 CORROSION PREVENTION

Anodic polarization curves of Cr, Ni and Fe in 1 N H2SO4 solution

Page 11: 4.0 CORROSION PREVENTION

Influence of Cr on corrosion resistance of iron base alloy

Page 12: 4.0 CORROSION PREVENTION

Influence of Ni on corrosion resistance of iron base alloy

Page 13: 4.0 CORROSION PREVENTION

Influence of Cr on iron base alloy containing 8.3-9.8wt.%Ni

Page 14: 4.0 CORROSION PREVENTION

3. Carbon

Very strong austenite forming element (30x more effective than Ni). I.e. if austenitic stainless steel 18Cr-8Ni contains ≤0.007%C, its structure will convert to ferritic structure. However the concentration of carbon is usually limited to ≤ 0.08%C (normal stainless steels) and ≤0.03%C (low carbon stainless steels to avoid sensitization during welding).

Page 15: 4.0 CORROSION PREVENTION

Minor alloying elements :

Manganese Austenitic forming element. When necessary can be

used to substitute Ni. Concentration of Mn in stainless steel is usually 2-3%.

Molybdenum Ferritic forming element. Added to increase pitting

corrosion resistance of stainless steel (2-4%). Molybdenum addition has to be followed by decreasing

chromium concentration (i.e. in 18-8SS has to be decreased down to 16-18%) and increasing nickel concentration (i.e. has to be increased up to 10-14%).

Improves mechanical properties of stainless steel at high temperature. Increase aqueous corrosion resistance of material exposed in reducing acid.

Page 16: 4.0 CORROSION PREVENTION

Tungsten Is added to increase the strength and toughness

of martensitic stainless steel.

Nitrogen (up to 0.25%)Stabilize austenitic structure. Increases strength

and corrosion resistance. Increases weld ability of duplex SS.

Titanium, Niobium and TantalumTo stabilize stainless steel by reducing susceptibility

of the material to intergranular corrosion. Ti addition > 5x%C. Ta+Nb addition > 10x%C.

Page 17: 4.0 CORROSION PREVENTION

CopperIs added to increase corrosion resistance of

stainless steel exposed in environment containing sulfuric acid.

Silicon Reduce susceptibility of SS to pitting and crevice

corrosion as well as SCC.

Page 18: 4.0 CORROSION PREVENTION

Influence of alloying elements on pitting corrosion resistance of stainless steels

Page 19: 4.0 CORROSION PREVENTION

Influence of alloying elements on crevice corrosion resistance of stainless steels

Page 20: 4.0 CORROSION PREVENTION

Influence of alloying elements on SCC resistance of stainless steels

Page 21: 4.0 CORROSION PREVENTION

Five basic types of stainless steels :

Austenitic - Susceptible to SCC. Can be hardened by only by cold working. Good toughness and formability, easily to be welded and high corrosion resistance. Nonmagnetic except after excess cold working due to martensitic formation.

Martensitic - Application: when high mechanical strength and wear resistance combined with some degree of corrosion resistance are required. Typical application include steam turbine blades, valves body and seats, bolts and screws, springs, knives, surgical instruments, and chemical engineering equipment.

Ferritic - Higher resistance to SCC than austenitic SS. Tend to be notch sensitive and are susceptible to embrittlement during welding. Not recommended for service above 3000C because they will loss their room temperature ductility.

Page 22: 4.0 CORROSION PREVENTION

Duplex (austenitic + ferritic) – has enhanced resistance to SCC with corrosion resistance performance similar to AISI 316 SS. Has higher tensile strengths than the austenitic type, are slightly less easy to form and have weld ability similar to the austenitic stainless steel. Can be considered as combining many of the best features of both the austenitic and ferritic types. Suffer a loss impact strength if held for extended periods at high temperatures above 3000C.

Precipitation hardening - Have the highest strength but require proper heat-treatment to develop the correct combination of strength and corrosion resistance. To be used for specialized application where high strength together with good corrosion resistance is required.

Page 23: 4.0 CORROSION PREVENTION
Page 24: 4.0 CORROSION PREVENTION
Page 25: 4.0 CORROSION PREVENTION
Page 26: 4.0 CORROSION PREVENTION
Page 27: 4.0 CORROSION PREVENTION
Page 28: 4.0 CORROSION PREVENTION
Page 29: 4.0 CORROSION PREVENTION
Page 30: 4.0 CORROSION PREVENTION
Page 31: 4.0 CORROSION PREVENTION

Stress Corrosion Cracking of Stainless Steel Stress corrosion cracking (SCC) is defined as

crack nucleation and propagation in stainless steel caused by synergistic action of tensile stress, either constant or slightly changing with time, together with crack tip chemical reactions or other environment-induced crack tip effect.

SCC failure is a brittle failure at relatively low constant tensile stress of an alloy exposed in a specific corrosive environment.

However the final fracture because of overload of remaining load-bearing section is no longer SCC.

Page 32: 4.0 CORROSION PREVENTION

Three conditions must be present simultaneously to produce SCC:

- a critical environment - a susceptible alloy - some component of tensile

stress

Page 33: 4.0 CORROSION PREVENTION

Tensile stress

Corrosive environment

Susceptible material

Stress corrosion cracking

Tensile stress is below yield point

Corrosive environment is often specific to the alloy system

Pure metals are more resistance to SCC but not immune and susceptibility increases with strength

Page 34: 4.0 CORROSION PREVENTION

Typical micro cracks formed during SCC of sensitized AISI 304 SS

Surface morphology

Page 35: 4.0 CORROSION PREVENTION

Example of crack propagation during transgranular stress corrosion cracking (TGSCC)

brass

Page 36: 4.0 CORROSION PREVENTION

Example of crack propagation during intergranular stress corrosion cracking (IGSCC) ASTM A245 carbon steel

Page 37: 4.0 CORROSION PREVENTION

Fracture surface of transgranular SCC on austenitic stainless steel in hot chloride solution

Fracture surface of intergranular SCC on carbon steel in hot nitric solution

Page 38: 4.0 CORROSION PREVENTION

Fracture surface due to intergranular SCC

Fracture surface due to local stress has reached its tensile strength value on the remaining section

Page 39: 4.0 CORROSION PREVENTION

Electrochemical effect

pitting

passive

active

cracking zones

Usual region for TGSCC, mostly is initiated by pitting corrosion (transgranular cracking propagation needs higher energy)

Usual region for IGSCC, SCC usually occurs where the passive film is relatively weak

Zone 1

Zone 2

Page 40: 4.0 CORROSION PREVENTION

Note that non-susceptible alloy-environment combinations, will not crack the alloy even if held in one of the potential zones.

Temperature and solution composition (including pH, dissolved oxidizers, aggressive ions and inhibitors or passivators) can modify the anodic polarization behavior to permit SCC.

Susceptibility to SCC cannot be predicted solely from the anodic polarization curve.

Page 41: 4.0 CORROSION PREVENTION

Models of stress corrosion cracking Slip step dissolution model Discontinuous intergranular crack growth Crack nucleation by rows of corrosion

micro-tunnels Absorption induced cleavage Surface mobility (atoms migrate out of

the crack tips) Hydrogen embrittlement→HIC

Page 42: 4.0 CORROSION PREVENTION

Control/prevention : Reduce applied stress level Remove residual tensile stress (internal

stress) Lowering oxidizing agent and/or critical

species from the environment Add inhibitor Use more resistant alloys Cathodic protection

Page 43: 4.0 CORROSION PREVENTION

2. Alteration of Environment

Typical changes in medium are : Lowering temperature – but there are cases

where increasing T decreases attack. E.g hot, fresh or salt water is raised to boiling T and result in decreasing O2 solubility with T.

Decreasing velocity – exception ; metals & alloys that passivate (e.g stainless steel) generally have better resistance to flowing mediums than stagnant. Avoid very high velocity because of erosion-corrosion effects.

Page 44: 4.0 CORROSION PREVENTION

Removing oxygen or oxidizers – e.g boiler feedwater was deaerated by passing it thru a large mass of scrap steel. Modern practice – vacuum treatment, inert gas sparging, or thru the use of oxygen scavengers. However, not recommended for active-passive metals or alloys. These materials require oxidizers to form protective oxide films.

Changing concentration – higher concentration of acid has higher amount of active species (H ions). However, for materials that exhibit passivity, effect is normally negligible.

Page 45: 4.0 CORROSION PREVENTION

Environment factors affecting corrosion design :

Dust particles and man-made pollution – CO, NO, methane, etc.

Temperature – high T & high humidity accelerates corrosion.

Rainfall – excess washes corrosive materials and debris but scarce may leave water droplets.

Proximity to sea Air pollution – NaCl, SO2, sulfurous acid, etc. Humidity – cause condensation.

Page 46: 4.0 CORROSION PREVENTION

3. Design Do’s & Don’ts Wall thickness – allowance to accommodate for

corrosion effect. Avoid excessive mechanical stresses and stress

concentrations in components exposed to corrosive mediums. Esp when using materials susceptible to SCC.

Avoid galvanic contact / electrical contact between dissimilar metals to prevent galvanic corrosion.

Avoid sharp bends in piping systems when high velocities and/or solid in suspension are involved – erosion corrosion.

Avoid crevices – e.g weld rather than rivet tanks and other containers, proper trimming of gasket, etc.

Page 47: 4.0 CORROSION PREVENTION

Avoid sharp corners – paint tends to be thinner at sharp corners and often starts to fail.

Provide for easy drainage (esp tanks) – avoid remaining liquids collect at bottom. E.g steel is resistant against concentrated sulfuric acid. But if remaining liquid is exposed to air, acid tend to absorb moisture, resulting in dilution and rapid attack occurs.

Avoid hot spots during heat transfer operations – localized heating and high corrosion rates. Hot spots also tend to produce stresses – SCC failures.

Design to exclude air – except for active-passive metals and alloys coz they require O2 for protective films.

Most general rule : AVOID HETEROGENEITY!!!

Page 48: 4.0 CORROSION PREVENTION

4. Protective Coatings / Wrapping

Provide barrier between metal and environment. Coatings may act as sacrificial anode or release

substance that inhibit corrosive attack on substrate. Metal coatings :

Noble – silver, copper, nickel, Cr, Sn, Pb on steel. Should be free of pores/discontinuity coz creates small anode-large cathode leading to rapid attack at the damaged areas.

Sacrificial – Zn, Al, Cd on steel. Exposed substrate will be cathodic & will be protected.

Application – hot dipping, flame spraying, cladding, electroplating, vapor deposition, etc.

Page 49: 4.0 CORROSION PREVENTION

Surface modification – to structure or composition by use of directed energy or particle beams. E.g ion implantation and laser processing.

Inorganic coating : cement coatings, glass coatings, ceramic coatings, chemical conversion coatings.

Chemical conversion – anodizing, phosphatizing, oxide coating, chromate.

Organic coating : paints, lacquers, varnishes. Coating liquid generally consists of solvent, resin and pigment. The resin provides chemical and corrosion resistance, and pigments may also have corrosion inhibition functions.

Page 50: 4.0 CORROSION PREVENTION

5. Cathodic and Anodic Protection5.1: Cathodic Protection Cathodic Protection (CP) was employed before the science of

electrochemistry had been developed; CP is achieved by supplying electrons to the metal structure

to be protected. (M Mn+ + ne) and (2H+ + 2e H2); Examination of equation indicates the addition of electrons to

the structure will tend to suppress metal dissolution and increase the rate of hydrogen dissolution;

If current is considered to flow from (+) to (-), then a structured is protected if current enters it from the electrolyte;

Conversely, accelerated corrosion occurs if current passes from the metal to the electrolyte, this current convention has been adopted in cathodic protection technology and is used here for consistency;

Page 51: 4.0 CORROSION PREVENTION

There 2 ways to cathodically protect a structure:(i) by an external power supply(ii) by appropriate galvanic coupling

Page 52: 4.0 CORROSION PREVENTION

Figure illustrates CP by impressed current; Here, an external dc power supply is connected to an

underground tank, the negative terminal of the power supply is connected to the tank, and the positive terminal to an inert anode such as graphite or Duriron.

The electric leads to the tank and inert the electrode are carefully insulated to prevent current leakage;

The anode is usually surrounded by backfill consisting of coke breeze, gypsum or bentonite which improves electric contact between the anode and the surrounding soil.

In figure, current passes to the metallic structure and corrosion is suppressed;

Page 53: 4.0 CORROSION PREVENTION

CP by galvanic coupling to Mg is shown in Fig 6.2; Mg is anodic with respect to steel and corrodes

preferentially when galvanic coupled; The anode in this case is called a sacrificial anode since it is consumed during the protection of the steel structure;

CP using sacrificial anodes can also be used to protect buries pipelines; shown Fig 6.3. the anodes are spaced along the pipe to ensure uniform current distribution;

Page 54: 4.0 CORROSION PREVENTION
Page 55: 4.0 CORROSION PREVENTION
Page 56: 4.0 CORROSION PREVENTION

5.2 Anodic Protection In contrast to CP, anodic protection (AP) is relatively new; This technique was developed using electrode kinetics principles

and is somewhat difficult to describe without introducing advanced concepts of electrochemical theory;

Simply, AP is based is based on the formation of a protective film on metals by externally applied anodic currents.

This usually except for metals with active-passive transitions such as Ni, Fe, Cr, Ti and their alloys;

If carefully controlled anodic currents are applied to these materials, they are passivated and the rate of metal dissolution is decreased;

To anodically protect a structure, a device called a potentiostat is required;

A potentiostat is an electronic device that maintains a metal at a constant potential with respect to a reference electrode.

Page 57: 4.0 CORROSION PREVENTION

The potentiostat has three terminals, one connected to the tank, another to an auxiliary cathode (a platinum or platinum-clad electrode) and the third to a reference electrode (e.g. calomel cell);

In operation, the potentiostat maintains a constant potential between the tank and the reference electrode;

The optimum potential for protection is determined by electrochemical measurements;

Page 58: 4.0 CORROSION PREVENTION
Page 59: 4.0 CORROSION PREVENTION