For Residential & Light Commercial Applications
4‐Ton 8 Zone Multi‐Split Heat Pump System
EXPERTISE AND INNOVATION
ENERGY EFFICIENCY
INDIVIDUAL COMFORT AND CONTROL
BUILT‐IN RELIABILITY
The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone comfort. Connecting up to 8 indoor units to a single outdoor unit reduces installation space and costs while maximizing comfort and energy savings. With a choice of three indoor unit types in a wide range of capacities, the Super Multi Plus allows mixed and matched combinations for absolute comfort in almost any residential application.
Integrated with an inverter “variable speed” compressor, Daikin Super Multi PLUS systems deliver the capacity required to maintain desired room conditions, typically reducing energy consumption by 30% compared to traditional fixed speed systems. This technology minimizes temperature fluctuations and provides continuous cooling and heating comfort with maximum energy savings.
All major components are engineered and manufactured by Daikin, ensuring maximum performance, reliability and efficiency. The standard warranty provides a solid level of protection on the Super Multi PLUS system. Systems installed by an authorized Daikin Dealer who has completed Daikin’s advanced training can take advantage of Warranty Plus – the best warranty in the industry.
Find a Daikin Dealer near you at www.daikinac.com.
The standard wireless controller provides individual temperature control at the click of the button. Most Indoor units are also compatible with the new Daikin ENVi intelligent thermostat, offering a more advanced solution, designed with energy savings performance in mind. With the freedom to access, program and control the system from a smart phone, tablet, or computer, users can have peace of mind ‐ anytime, anywhere. Note: The Daikin ENVi thermostat
is not compatible with the FFQ Indoor Units
DESIGN FLEXIBILITYThe Super Multi PLUS Split System can be combined with a variety of ducted and ductless models with a total of 15 indoor unit variations.
Indoor Unit AvailabilityCapacity
Indoor Type 7 MBH 9 MBH 12 MBH 15 MBH 18 MBH 24 MBHWall MountSlim Duct2' x 2' Cassette
CTXS_H, CTXS_LV, FTXS_LV
Wall Mounted UnitBlends with any décor with it’s sleek and sophisticated designEnhanced indoor air quality with the titanium apatite photocatalytic air purification filter which absorbs microscopic particles and decomposes odorsIncreased energy savings with the intelligent eye function which reduces operation in unoccupied spaces
FDXS_LV, CDXS_LV
Concealed Slim DuctMaximized floor and wall space with it’s compact and concealed designUndisturbed comfort with low operating sound levelsCleaner air with the removal or airborne dust particles by the standard mold proof air filter
FFQ_LV
2’ X 2’ Ceiling CassetteEnhanced comfort with uniform airflow and temperature distributionDraught free protection with horizontal air dischargeSimple installation with an easy‐to‐fit decoration panel that blends with any interior designEasy maintenance with an easy‐to‐clean grille and washable long life filter
BPMKS
Branch Provider UnitVaries the refrigerant volume to meet the cooling or heating requirements of each room connected to the system.Facilitates zone on/off and capacity control to operate rooms individually via zone temperature controlsSimple installation with flare nut connections
REFNET joint
Reduces the amount of work involved in installation and increases the reliability of the system.
NEW!
LEADING TECHNICAL PERFORMANCE
Outdoor Units – RMXS48LVJUModel Name RMXS48LVJUNominal Capacity (Cooling / Heating) Btu/h 48,000 / 54,000
SEER / HSPFNon Ducted 18.8 / 11.3Mixed 16.5/10.5Ducted 14.1/9.6
EER / COPNon Ducted 10.3/3.0Mixed 9.8/2.9Ducted 9.3/2.7
Power Supply 208/230V - 1Ø - 60Hz Minimum Circuit Amps A 27.0Maximum Overcurrent Protection A 30.0Sound Pressure - (Cooling/Heating) dB(A) 56/58Connection Ratio (Max Capacity for BPMKS Boxes) 50 - 130%Number of Connectable Indoor Units 2 to 8Number of Connectable BP Units 1 to 3Total System Piping Length ft. (m) 440 (135)Max. Piping Length(OU to BP Box) ft. (m) 180 (55)Max. Piping Length(IU to BP Box) ft. (m) 49 (15)Total Piping Length (OU to BP Box) ft. (m) 180 (55)Total Piping Length (BP to IU) ft. (m) 262 (80)Max. Piping Height (OU to IU) ft. (m) 98 (30)Max. Piping Height (IU to BP Box) ft. (m) 98 (30)Max. Piping Height (BP to BP Box) ft. (m) 49 (15)Piping Connection Kit KHRP26A22TOperating Range – (Cooling/Heating) °F DB 23 – 115/5 - 75Dimensions (H x W x D) in. 52-15/16 x 35-7/16 x 12-5/8Net Weight lbs. 283.0
BP UnitsModel Name BPMKS048A2U BPMKS049A3U
Power Supply Single phase 60Hz 208/230VPower Consumption W 10 10Running Current A 0.05 0.05Sound Pressure - (Cooling/Heating) dB(A) 32/32 32/32Number of Connectable Indoor Units 1 to 2 1 to 3Min. Connection Combination 7,000 7,000Max. Connection Combination 48,000 62,000
Piping Connections (O.D.)
LiquidOutdoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3Indoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3Connection Type Flare Flare
GasOutdoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3Indoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3Connection Type Flare Flare
Dimensions (H x W x D) in. 7-1/16 x 11-9/16 x 13-3/4Net Weight lbs. 18.0 20.0
Nominal Conditions:Cooling ModeIndoor: 80 °F DB / 67 °F WBOutdoor: 95 °F DBPipe Length: 25 ft.Level Difference: 0 ft.
Heating ModeIndoor: 70 °F DBOutdoor: 47 °F DB / 43 °F WBPipe Length: 25 ft.Level Difference: 0 ft.
Note:Specifications are subject to change without notice.
Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted UnitsModel Name CTXS07LVJU CTXS09HVJU CTXS12HVJU FTXS15LVJU FTXS18LVJU FTXS24LVJUAirflow-Wet (H/M/L/SL) CFM 332/261/194/145 388/335/283/- 388/335/283/- 568/477/385/360 583/484/385/360 643/494/350/328Airflow-Dry (H/M/L/SL) CFM 350/290/233/219 400/357/314/- 400/357/314/- 593/505/417/371 625/526/431/399 699/572/445/403Sound Pressure - Cooling (H/M/L/SL) dB(A) 38/32/25/22 44/40/35/- 45/41/36/- 45/40/35/32 46/41/36/33 51/44/37/34Sound Pressure - Heating (H/M/L/SL) dB(A) 38/33/28/25 44/39/34/- 45/40/35/- 43/38/33/30 45/40/35/32 48/42/37/34
Piping ConnectionsLiquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 5/8Condensate Drain Connection (O.D.) in. Ø 5/8 Ø 11/16 Ø 11/16 Ø 5/8 Ø 5/8 Ø 5/8
Dimensions (H x W x D) in. 11-5/8 x 31-1/2 x 8-7/16 11-7/16 x 31-5/16 x 9-3/8 13-3/8 x 41-5/8 x 9-3/4 Net Weight lbs. 20.0 20.0 20.0 31.0 31.0 31.0
Indoor Units - FDXS_LVJU and CDXS_LVJU Slim Duct UnitsModel Name FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU External Static Pressure "W.G. 0.12 0.12 0.16 0.16 0.16Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297Sound Pressure - Cooling (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31 Sound Pressure - Heating (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31
Piping ConnectionsLiquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 1/2Condensate Drain in. Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32
Dimensions (H x W x D) in. 7-7/8 x 27-9/16 x 24-7/16 7-7/8x35-7/16x24-7/16 Net Weight lbs. 47.0 47.0 60.0 60.0 60.0
Indoor Units - FFQ_LVJU 2’x2’Duct UnitsModel Name FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU Airflow Rate (H/L) CFM 318/230 353/230 424/283 530/353Sound Pressure - Cooling (H/L) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 Sound Pressure - Heating (H/L dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31
Piping ConnectionsLiquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2Condensate Drain (O.D.) in. Ø 1-1/32 Ø 1-1/32 Ø 1-1/32 Ø 1-1/32
Dimensions – Unit (H x W x D) in. 11-1/4 x 22-5/8 x 22-5/8Dimensions – Deco Panel (H x W x D) in. 2-1/4 x 27-5/8 x 27-5/8Net Weight lbs. 38.5 38.5 38.5 38.5
0.6‐Ton 0.75‐Ton 1.0‐Ton 1.25‐Ton 1.5‐Ton 2.0‐Ton
Up to 2 Zones Up to 3 Zones
Up to 8 indoor units can be connected to a single outdoor unit
A High Efficiency solution with optimum flexibility to provide zoning for with the connection of up to 8 indoor units utilizing long pipe lengths, ease of installation with standardized line‐sets, simplified electrical requirements and staged installations
TIME‐SAVING INSTALLATION AND EASELonger Refrigerant Piping
Simplified Electrical Wiring
The outdoor unit and BP units operate from separate 208/230V single‐phase power supplies. Indoor units are powered from the BP unit and wired as Daikin’s current 4 wire single split systems reducing the wiring size and easing installation
More than 60% in physical space savingsMore than 80% in total (including clearances) space savings
Space Saving Design
Traditional Outdoor Unit
Daikin RMXS
35‐7/16”
12‐5/8”
35‐1/8”
38‐11/16”
Installation Space
Piping Requirements Allowable Length Details
Maximum allowable length
Between outdoor and BP units Total piping length Piping length between outdoor and BP units ≤ 180 ft (55 m) - [Example] a+b+c+d+e ≤ 180 ft
Between BP and indoor units Total piping length Piping length between BP and indoor units: 262 ft (80 m) - [Example] f+g+h+i+j+k+l ≤ 262ft
Between BP and indoor unit 1 room length Piping length between BP and indoor unit ≤ 49 ft (15 m) - [Example] f, g, h, i, j, k, l ≤ 49 ft
Allowable height
Between outdoor and indoor units
Difference in height
Difference in height between outdoor and indoor units (H1) ≤ 98 ft (30 m)
Between outdoor and BP units Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)
Between BP and BP units Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)
Between indoor and indoor units Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)
Minimum allowable length Piping lengthPipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft
Allowable length after the REFNET branch Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m)[Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft
Additional refrigerant calculation
Longer refrigerant piping capabilities offers much more flexibility in the choice of installation positions for the indoor units, and greatly simplifies system layout.
Distributor or Dealer Information: Daikin AC (Americas), Inc.1645 Wallace Drive, Suite 110
Carrollton, TX 75006www.daikinac.com
866.4DAIKIN972.245.1510
For all equipment installation & application limitations please refer to the specific Engineering Data Books.Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.
www.likin-daikin.com
• Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
• Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
• Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local Daikin sales office.
WARNINGS:
© 2013 Daikin Industries, Limited.Daikin, Daikin AC Absolute Comfort, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD.
Use of the AHRI Certified™ mark indicates a manufacturer'sparticipation in the certification program. For verification of
certification for individual products, go to www.ahridirectory.org
PFSMPUSE13-01R
System Operation RangeCooling Operation 23 °FDB – 115 °FDB
Ambient Temperature
57 °FWB – 82 °FDB Indoor Room Temperature
Heating Operation 5 °FDB – 60 °FWB Ambient Temperature
50 °FDB – 82 °FDB Indoor Room Temperature
Note: No low ambient option exists with this product line.
Sales Bulletin #MS004 Date: January 15, 2013
To: Daikin Sales, Service, and Distribution
Subject: New 4-Ton 8 Zone Super Multi PLUS System (RMXS) and New Multi-Split Indoor
Units
Daikin AC is pleased to introduce the new 8 Zone Super Multi PLUS System targeting residential and light commercial markets. The Super Multi PLUS complements and expands our current multi-split portfolio and provides superior efficiency and flexibility with the ability to connect 2 to 8 indoor units from a variety of indoor unit options including Daikin’s new 2’ X 2’ ceiling cassette units (9 – 18 MBH), wall mounted units (7 MBH – 24 MBH), and new extended range of slim duct units (9 – 24 MBH).
Product Overview
The Super Multi PLUS system is available from April 2013 and the launch will include the following new models: -
RMXS48LVJU 4.0 Ton Super Multi PLUS Condensing Unit BPMKS048A2U 2 Zone Branch Provider Box BPMKS049A3U 3 Zone Branch Provider Box CDXS24LVJU 2.0 Ton Slim Duct Built-in Unit FFQ09LVJU 0.75 Ton 2’ X 2’ Ceiling Cassette Unit FFQ12LVJU 1.0 Ton 2’ X 2’ Ceiling Cassette Unit FFQ15LVJU 1.25 Ton 2’ X 2’ Ceiling Cassette Unit FFQ18LVJU 1.5 Ton 2’ X 2’ Ceiling Cassette Unit
Daikin AC’s new Branch Provider (BP) unit allows the Super Multi PLUS to connect from 2 to 8 indoor units with indoor unit capacities up to 130% (62,000 Btu/h) of the outdoor unit.
Daikin AC ( A merica s) , Inc. 1645 W allace Drive , Sui t e 110
Carrol l ton , T X 75006 972-245-1510
www.daikinac.com
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 2 of 10 Product Information
The new Super Multi can serve up to 8 rooms with the addition of indoor units extending our current range of indoor unit availability to include a total of 15 models in 3 different types for design flexibility with individual comfort control.
Product class leading efficiency levels (4-Ton Multi-Split Heat Pump) are available with ratings up to SEER 18.8 for non-ducted combinations and up to HSPF 11.3.
2’ X 2’ Ceiling Cassette (New)
To meet the growing demand of the market and to satisfy the requests of customers, Daikin AC is pleased to introduce the new 2’ X 2’ ceiling cassette, FFQ_LVJU, for multi- split systems only to complement our current range of indoor units. These units provide customizable comfort with four-way directional airflow and easy adjustments for corner or corridor installation. Compact with an easy-to-clean grille and sophisticated decoration panel, these units are designed to fit nearly flush with or into a standard ceiling tile for an unobtrusive interior finish. Ideal for both residential and light commercial applications, the 2’ X 2’ is great for new or retrofit homes, offices, and retail spaces.
The 2’ X 2’ is compatible with the new Navigation Remote Controller BRC1E72. The configurable display offers 3 options with an advanced display great for residential applications and a simplified display ideal for applications such as hotels wanting to only provide the necessary buttons to users for comfort without confusion. Refer to Sales Bulletin #CT013 for more information.
Wall Mount (Extended Range) and Slim Duct (New) Units
The new slim duct, CDXS24LVJU, and addition of the current LV-Series wall mount, FTXS24LVJU, extends the indoor unit capacity range up to 24 MBH, enhancing the versatility of the Super Multi and offering solutions for larger spaces having more cooling or heating requirements. Indoor units are provided with a wireless controller as standard or can be utilized with the new optional Daikin ENVi controller for smart comfort available April 2013 (more information to come at the end of January). Please note indoor units in 24 MBH capacities are only available with the Super Multi PLUS.
Branch Provider (BP) Unit
The BPMKS Branch Provider boxes allow indoor units of different capacities to be connected and then vary refrigerant volume to meet cooling and heating requirements of individual room zones. Available in 2 and 3 port units, up to 3 BP units can be connected to the Super Multi PLUS for initial full system integration or phased installation. To simplify installation the BP boxes come with flare connections removing the need for brazing at the box location.
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 3 of 10 Technical Specifications
Outdoor Units BP Units
Indoor Units
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 4 of 10 Piping Limitations
Piping Requirements Branch with REFNET Joint Maximum allowable length
Between outdoor and BP units
Total piping length
Piping length between outdoor and BP units ≤ 180 ft (55 m) [Example] a+b+c+d+e ≤ 180 ft
Between BP and indoor units
Total piping length
Piping length between BP and indoor units: 262 ft (80 m) [Example] f+g+h+i+j+k+l ≤ 262ft
Between BP and indoor unit
1 room length
Piping length between BP and indoor unit ≤ 49 ft (15 m) [Example] f, g, h, i, j, k, l ≤ 49 ft
Allowable height
Between outdoor and indoor units
Difference in height
Difference in height between outdoor and indoor units (H1) ≤ 98 ft (30 m)
Between outdoor and BP units
Difference in height
Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)
Between BP and BP units
Difference in height
Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)
Between indoor and indoor units
Difference in height
Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)
Minimum allowable length Piping
length Pipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft
Allowable length after the REFNET branch
Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m) [Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft
Additional refrigerant calculation
Electrical Wiring
The outdoor unit and BP units operate from separate 208/230V single-phase power supplies. Indoor units are powered from the BP unit and
wired as Daikin’s current 4 wire single split systems reducing the wiring size and easing installation
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 5 of 10 Operation Range
Cooling Operation 23 °FDB – 115 °FDB
Ambient Temperature
57 °FWB – 82 °FDB Indoor Room Temperature
Heating Operation 5 °FDB – 60 °FWB
Ambient Temperature
50 °FDB – 82 °FDB Indoor Room Temperature
Note: No low ambient option exists with this product line.
Competitive Comparison
Technical Specification vs. Competing Manufacturer Manufacturer Daikin AC
RMXS48LVJU Company M Company F Company L Nominal Cooling Capacity Btu/h 48,000 48,000 48,000 54,000 Maximum Cooling Capacity Btu/h 54,000 54,000 51,100 63,200 Nominal Heating Capacity at 47 °F Btu/h 54,000 54,000 54,000 58,000 Maximum Heating Capacity at 47 °F Btu/h 61,000 60,000 57,000 64,000
SEER / HSPF
Non Ducted 18.8 / 11.3 15.0 / 8.7 17.0 / 9.8 18.4 / 8.7 Mixed 16.5 / 10.5 14.8 / 8.8 15.8 / 9.5 17.1 / 8.3 Ducted 14.1 / 9.6 14.7 / 8.9 14.7 / 9.3 15.8 / 8.0
EER / COP 47F
Non Ducted 10.3 / 3.0 8.3 / 3.28 9.25 / - 10.3 / 3.1 Mixed 9.8 / 2.9 7.8 / 3.14 8.97 / - n/a Ducted 9.3 / 2.7 7.4 / 3.00 8.70 / - n/a
Maximum Overcurrent Protection MOP (A) 30A 50A 40A N/A Minimum Circuit Amps MCA (A) 27A 32A N/A N/A Connected Capacity % 50 – 130 22 - 130 80 - 130 * - 135
Connectable Indoor Capacity Btu/h 24,000 - 62,400 70,200 62,000 73,000 Cooling Operating Range °F DB 23 – 115 23 – 115 23 – 115 14 – 118.4 Heating Operating Range °F DB 5 – 75 5 – 70 5 – 75 0 – 75
Max. Pipe Length ft
Total 433.0 377.0 377.0 475.7 OU to IU 230.0 230.0 180.0 295.3 Box to IU 49.0 49.0 49.0 49.2
Max Pipe Height Difference ft
OU to Box 98.0 49.0 98.0 n/a IU to IU 49.0 39.0 49.0 49.2 OU to IU 98.0 98.0 98.0 98.4
Indoor Unit Availability Indoor Type Wall Mounted Duct Mounted 2’ X 2’ 4 Way Ceiling Cassette Capacity (MBH) 07 09 12 15 18 24 09 12 15 18 24 09 12 15 18 24 Daikin AC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Company M ● ● ● ● ● ● ● ● ● ● ● ● ● Company L ● ● ● ● ● ● ● ● Company F ● ● ● ● ● ● ● ● ● ● ● ● ●
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 6 of 10
Product and Document Availability
Product and Documentation January February March April
TRL Pricing
Sales Presentation
Submittal Data Sheets
Engineering Data Book
Installation & Operations Manual
Product Flyer
General Catalogue
Sales Availability
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 7 of 10
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating
Capacity(kBT U/h)
Power Consumption
(kW) 43.2 90.0% 49.0 4.80 43.7 91.0% 49.5 4.85 44.2 92.0% 50.0 4.90 44.6 93.0% 50.5 4.95 45.1 94.0% 51.0 5.00 45.6 95.0% 51.5 5.05 46.1 96.0% 52.0 5.10 46.6 97.0% 52.5 5.15 47.0 98.0% 53.0 5.20 47.5 99.0% 53.5 5.24 48.0 100.0% 54.0 5.27 48.5 101.0% 54.1 5.28 49.0 102.0% 54.1 5.28 49.4 103.0% 54.2 5.28 49.9 104.0% 54.2 5.28 50.4 105.0% 54.3 5.29 50.9 106.0% 54.3 5.29 51.4 107.0% 54.4 5.29 51.8 108.0% 54.4 5.29 52.3 109.0% 54.5 5.29 52.8 110.0% 54.5 5.30 53.3 111.0% 54.6 5.30 53.8 112.0% 54.6 5.30 54.2 113.0% 54.7 5.30 54.7 114.0% 54.7 5.30 55.2 115.0% 54.8 5.31 55.7 116.0% 54.8 5.31 56.2 117.0% 54.9 5.31 56.6 118.0% 54.9 5.31 57.1 119.0% 55.0 5.31 57.6 120.0% 55.0 5.32 58.1 121.0% 55.1 5.32 58.6 122.0% 55.1 5.32 59.0 123.0% 55.2 5.32 59.5 124.0% 55.2 5.32 60.0 125.0% 55.3 5.33 60.5 126.0% 55.3 5.33 61.0 127.0% 55.4 5.33 61.4 128.0% 55.4 5.33 61.9 129.0% 55.5 5.33 62.0 129.2% 55.5 5.34
Appendix – System Capacity Details versus Combination Ratio Connected
Heating (60 Hz 230/208V) with Ducted Indoor Units
Total Indoor
Unit Capacity (kBTU/h)
Combination
(%) Heating
Capacity(kBT U/h)
Power Consumption
(kW) 24.0 50.0% 29.0 2.58 24.5 51.0% 29.5 2.62 25.0 52.0% 30.0 2.68 25.4 53.0% 30.5 2.74 25.9 54.0% 31.0 2.80 26.4 55.0% 31.5 2.86 26.9 56.0% 32.0 2.92 27.4 57.0% 32.5 2.98 27.8 58.0% 33.0 3.04
28.3 59.0% 33.5 3.10 28.8 60.0% 34.0 3.16 29.3 61.0% 34.5 3.21 29.8 62.0% 35.0 3.27 30.2 63.0% 35.5 3.33 30.7 64.0% 36.0 3.39 31.2 65.0% 36.5 3.45 31.7 66.0% 37.0 3.50 32.2 67.0% 37.5 3.56 32.6 68.0% 38.0 3.62 33.1 69.0% 38.5 3.67 33.6 70.0% 39.0 3.73 34.1 71.0% 39.5 3.79 34.6 72.0% 40.0 3.84 35.0 73.0% 40.5 3.90 35.5 74.0% 41.0 3.95 36.0 75.0% 41.5 4.01 36.5 76.0% 42.0 4.06 37.0 77.0% 42.5 4.12 37.4 78.0% 43.0 4.17 37.9 79.0% 43.5 4.22 38.4 80.0% 44.0 4.28 38.9 81.0% 44.5 4.33 39.4 82.0% 45.0 4.38 39.8 83.0% 45.5 4.44 40.3 84.0% 46.0 4.49 40.8 85.0% 46.5 4.54 41.3 86.0% 47.0 4.59 41.8 87.0% 47.5 4.64 42.2 88.0% 48.0 4.70 42.7 89.0% 48.5 4.75
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 8 of 10
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating
Capacity(kBT U/h)
Power Consumption
(kW) 43.2 90.0% 49.0 3.67 43.7 91.0% 49.5 3.70 44.2 92.0% 50.0 3.74 44.6 93.0% 50.5 3.77 45.1 94.0% 51.0 3.81 45.6 95.0% 51.5 3.84 46.1 96.0% 52.0 3.87 46.6 97.0% 52.5 3.91 47.0 98.0% 53.0 3.94 47.5 99.0% 53.5 3.98 48.0 100.0% 54.0 3.98 48.5 101.0% 54.1 3.99 49.0 102.0% 54.2 3.99 49.4 103.0% 54.3 4.00 49.9 104.0% 54.4 4.00 50.4 105.0% 54.5 4.01 50.9 106.0% 54.6 4.01 51.4 107.0% 54.7 4.02 51.8 108.0% 54.8 4.02 52.3 109.0% 54.9 4.02 52.8 110.0% 55.0 4.03 53.3 111.0% 55.1 4.03 53.8 112.0% 55.2 4.04 54.2 113.0% 55.3 4.04 54.7 114.0% 55.4 4.04 55.2 115.0% 55.5 4.05 55.7 116.0% 55.6 4.05 56.2 117.0% 55.7 4.05 56.6 118.0% 55.8 4.06 57.1 119.0% 55.9 4.06 57.6 120.0% 56.0 4.06 58.1 121.0% 56.1 4.06 58.6 122.0% 56.2 4.07 59.0 123.0% 56.3 4.07 59.5 124.0% 56.4 4.07 60.0 125.0% 56.5 4.08 60.5 126.0% 56.6 4.08 61.0 127.0% 56.7 4.08 61.4 128.0% 56.8 4.08 61.9 129.0% 56.9 4.08 62.0 129.2% 57.0 4.09
Heating (60 Hz 230/208V) with Wall Mounted Indoor Units
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating
Capacity(kBT U/h)
Power Consumption
(kW) 24.0 50.0% 29.0 2.13 24.5 51.0% 29.5 2.17 25.0 52.0% 30.0 2.21 25.4 53.0% 30.5 2.25 25.9 54.0% 31.0 2.30 26.4 55.0% 31.5 2.34 26.9 56.0% 32.0 2.38 27.4 57.0% 32.5 2.42 27.8 58.0% 33.0 2.46 28.3 59.0% 33.5 2.50 28.8 60.0% 34.0 2.54 29.3 61.0% 34.5 2.58
29.8 62.0% 35.0 2.62 30.2 63.0% 35.5 2.66 30.7 64.0% 36.0 2.70 31.2 65.0% 36.5 2.74 31.7 66.0% 37.0 2.78 32.2 67.0% 37.5 2.82 32.6 68.0% 38.0 2.86 33.1 69.0% 38.5 2.90 33.6 70.0% 39.0 2.93 34.1 71.0% 39.5 2.97 34.6 72.0% 40.0 3.01 35.0 73.0% 40.5 3.05 35.5 74.0% 41.0 3.09 36.0 75.0% 41.5 3.12 36.5 76.0% 42.0 3.16 37.0 77.0% 42.5 3.20 37.4 78.0% 43.0 3.24 37.9 79.0% 43.5 3.27 38.4 80.0% 44.0 3.31 38.9 81.0% 44.5 3.35 39.4 82.0% 45.0 3.38 39.8 83.0% 45.5 3.42 40.3 84.0% 46.0 3.46 40.8 85.0% 46.5 3.49 41.3 86.0% 47.0 3.53 41.8 87.0% 47.5 3.56 42.2 88.0% 48.0 3.60 42.7 89.0% 48.5 3.63
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 9 of 10
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating Capacity (kBTU/h)
Power Consumption
(kW) 43.2 90.0% 43.2 4.39 43.7 91.0% 43.7 4.47 44.2 92.0% 44.2 4.55 44.6 93.0% 44.6 4.63 45.1 94.0% 45.1 4.71 45.6 95.0% 45.6 4.79 46.1 96.0% 46.1 4.88 46.6 97.0% 46.6 4.96 47.0 98.0% 47.0 5.04 47.5 99.0% 47.5 5.13 48.0 100.0% 48.0 5.13 48.5 101.0% 48.1 5.14 49.0 102.0% 48.2 5.15 49.4 103.0% 48.3 5.15 49.9 104.0% 48.4 5.16 50.4 105.0% 48.5 5.16 50.9 106.0% 48.6 5.17 51.4 107.0% 48.7 5.17 51.8 108.0% 48.8 5.18 52.3 109.0% 48.9 5.18 52.8 110.0% 49.0 5.19 53.3 111.0% 49.1 5.19 53.8 112.0% 49.2 5.20 54.2 113.0% 49.3 5.20 54.7 114.0% 49.4 5.21 55.2 115.0% 49.5 5.21 55.7 116.0% 49.6 5.22 56.2 117.0% 49.7 5.22 56.6 118.0% 49.8 5.23 57.1 119.0% 49.9 5.23 57.6 120.0% 50.0 5.24 58.1 121.0% 50.1 5.24 58.6 122.0% 50.2 5.25 59.0 123.0% 50.3 5.25 59.5 124.0% 50.4 5.26 60.0 125.0% 50.5 5.26 60.5 126.0% 50.6 5.27 61.0 127.0% 50.7 5.27 61.4 128.0% 50.8 5.28 61.9 129.0% 50.9 5.28 62.0 129.2% 51.0 5.28
Cooling (60 Hz 230/208V) with Ducted Indoor Units
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating Capacity (kBTU/h)
Power Consumption
(kW) 24.0 50.0% 24.0 1.92 24.5 51.0% 24.5 1.97 25.0 52.0% 25.0 2.01 25.4 53.0% 25.4 2.06 25.9 54.0% 25.9 2.11 26.4 55.0% 26.4 2.16 26.9 56.0% 26.9 2.21 27.4 57.0% 27.4 2.26 27.8 58.0% 27.8 2.31 28.3 59.0% 28.3 2.36 28.8 60.0% 28.8 2.42 29.3 61.0% 29.3 2.47
29.8 62.0% 29.8 2.53 30.2 63.0% 30.2 2.58 30.7 64.0% 30.7 2.64 31.2 65.0% 31.2 2.70 31.7 66.0% 31.7 2.75 32.2 67.0% 32.2 2.81 32.6 68.0% 32.6 2.87 33.1 69.0% 33.1 2.93 33.6 70.0% 33.6 2.99 34.1 71.0% 34.1 3.06 34.6 72.0% 34.6 3.12 35.0 73.0% 35.0 3.18 35.5 74.0% 35.5 3.25 36.0 75.0% 36.0 3.31 36.5 76.0% 36.5 3.38 37.0 77.0% 37.0 3.45 37.4 78.0% 37.4 3.51 37.9 79.0% 37.9 3.58 38.4 80.0% 38.4 3.65 38.9 81.0% 38.9 3.72 39.4 82.0% 39.4 3.79 39.8 83.0% 39.8 3.87 40.3 84.0% 40.3 3.94 40.8 85.0% 40.8 4.01 41.3 86.0% 41.3 4.09 41.8 87.0% 41.8 4.16 42.2 88.0% 42.2 4.24 42.7 89.0% 42.7 4.32
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)
Page 10 of 10
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating
Capacity(kBT U/h)
Power Consumption
(kW) 43.2 90.0% 43.2 3.91 43.7 91.0% 43.7 3.98 44.2 92.0% 44.2 4.05 44.6 93.0% 44.6 4.13 45.1 94.0% 45.1 4.20 45.6 95.0% 45.6 4.28 46.1 96.0% 46.1 4.35 46.6 97.0% 46.6 4.43 47.0 98.0% 47.0 4.51 47.5 99.0% 47.5 4.59 48.0 100.0% 48.0 4.64 48.5 101.0% 48.2 4.65 49.0 102.0% 48.5 4.67 49.4 103.0% 48.7 4.69 49.9 104.0% 48.9 4.71 50.4 105.0% 49.1 4.73 50.9 106.0% 49.3 4.75 51.4 107.0% 49.5 4.77 51.8 108.0% 49.7 4.79 52.3 109.0% 49.9 4.81 52.8 110.0% 50.0 4.82 53.3 111.0% 50.2 4.84 53.8 112.0% 50.4 4.85 54.2 113.0% 50.5 4.87 54.7 114.0% 50.7 4.88 55.2 115.0% 50.8 4.90 55.7 116.0% 50.9 4.91 56.2 117.0% 51.1 4.92 56.6 118.0% 51.2 4.94 57.1 119.0% 51.3 4.95 57.6 120.0% 51.4 4.96 58.1 121.0% 51.5 4.97 58.6 122.0% 51.6 4.98 59.0 123.0% 5.7 4.99 59.5 124.0% 51.8 4.99 60.0 125.0% 51.8 5.00 60.5 126.0% 51.9 5.01 61.0 127.0% 52.0 5.01 61.4 128.0% 52.0 5.02 61.9 129.0% 52.1 5.02 62.0 129.2% 52.1 5.03
Cooling (60 Hz 230/208V) with Wall Mounted Indoor Units
Total Indoor Unit Capacity
(kBTU/h)
Combination
(%) Heating
Capacity(kBT U/h)
Power Consumption
(kW) 24.0 50.0% 24.0 1.78 24.5 51.0% 24.5 1.81 25.0 52.0% 25.0 1.85 25.4 53.0% 25.4 1.89 25.9 54.0% 25.9 1.92 26.4 55.0% 26.4 1.96 26.9 56.0% 26.9 2.00 27.4 57.0% 27.4 2.04 27.8 58.0% 27.8 2.09 28.3 59.0% 28.3 2.13 28.8 60.0% 28.8 2.17 29.3 61.0% 29.3 2.22
29.8 62.0% 29.8 2.26 30.2 63.0% 30.2 2.31 30.7 64.0% 30.7 2.35 31.2 65.0% 31.2 2.40 31.7 66.0% 31.7 2.45 32.2 67.0% 32.2 2.50 32.6 68.0% 32.6 2.55 33.1 69.0% 33.1 2.60 33.6 70.0% 33.6 2.66 34.1 71.0% 34.1 2.71 34.6 72.0% 34.6 2.76 35.0 73.0% 35.0 2.82 35.5 74.0% 35.5 2.88 36.0 75.0% 36.0 2.93 36.5 76.0% 36.5 2.99 37.0 77.0% 37.0 3.05 37.4 78.0% 37.4 3.11 37.9 79.0% 37.9 3.17 38.4 80.0% 38.4 3.24 38.9 81.0% 38.9 3.30 39.4 82.0% 39.4 3.36 39.8 83.0% 39.8 3.43 40.3 84.0% 40.3 3.49 40.8 85.0% 40.8 3.56 41.3 86.0% 41.3 3.63 41.8 87.0% 41.8 3.70 42.2 88.0% 42.2 3.76 42.7 89.0% 42.7 3.84
Published by Daikin AC Product Marketing Department
(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without
notice and without incurring any obligation.)