21
For Residential & Light Commercial Applications 4Ton 8 Zone MultiSplit Heat Pump System

4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Embed Size (px)

Citation preview

Page 1: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

For Residential & Light Commercial Applications

4‐Ton 8 Zone Multi‐Split Heat Pump System

Page 2: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

EXPERTISE AND INNOVATION

ENERGY EFFICIENCY

INDIVIDUAL COMFORT AND CONTROL

BUILT‐IN RELIABILITY

The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone comfort. Connecting up to 8 indoor units to a single outdoor unit reduces installation space and costs while maximizing comfort and energy savings. With a choice of three indoor unit types in a wide range of capacities, the Super Multi Plus allows mixed and matched combinations for absolute comfort in almost any residential application.

Integrated with an inverter  “variable speed” compressor, Daikin Super Multi PLUS systems deliver the capacity required to maintain desired room conditions, typically reducing energy consumption by 30% compared to traditional fixed speed systems. This technology minimizes temperature fluctuations and provides continuous cooling and heating comfort with maximum energy savings.

All major components are engineered and manufactured by Daikin, ensuring maximum performance, reliability and efficiency. The standard warranty provides a solid level of protection on the Super Multi PLUS system. Systems installed by an authorized Daikin Dealer who has completed Daikin’s advanced training can take advantage of Warranty Plus – the best warranty in the industry.

Find a Daikin Dealer near you at  www.daikinac.com.

The standard wireless controller provides individual temperature control at the click of the button. Most Indoor units are also compatible with the new Daikin ENVi intelligent thermostat, offering a more advanced solution, designed with energy savings performance in mind. With the freedom to access, program and control the system from a smart phone, tablet, or computer, users can have peace of mind  ‐ anytime, anywhere. Note: The Daikin ENVi thermostat 

is not compatible with the FFQ Indoor Units

Page 3: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

DESIGN FLEXIBILITYThe Super Multi PLUS Split System can be combined with a variety of ducted and ductless models with a total of 15 indoor unit variations.

Indoor Unit AvailabilityCapacity

Indoor Type 7 MBH 9 MBH 12 MBH 15 MBH 18 MBH 24 MBHWall MountSlim Duct2' x 2' Cassette

CTXS_H, CTXS_LV, FTXS_LV

Wall Mounted UnitBlends with any décor with it’s sleek and sophisticated designEnhanced indoor air quality with the titanium apatite photocatalytic air purification filter which absorbs microscopic particles and decomposes odorsIncreased energy savings with the intelligent eye function which reduces operation in unoccupied spaces

FDXS_LV, CDXS_LV

Concealed Slim DuctMaximized floor and wall space with it’s compact and concealed designUndisturbed comfort with low operating sound levelsCleaner air with the removal or airborne dust particles by the standard mold proof air filter

FFQ_LV

2’ X 2’ Ceiling CassetteEnhanced comfort with uniform airflow and temperature distributionDraught free protection with horizontal air dischargeSimple installation with an easy‐to‐fit decoration panel that blends with any interior designEasy maintenance with an easy‐to‐clean grille and washable long life filter

BPMKS

Branch Provider UnitVaries the refrigerant volume to meet the cooling or heating requirements of each room connected to the system.Facilitates zone on/off and capacity control to operate rooms individually via zone temperature controlsSimple installation with flare nut connections

REFNET joint

Reduces the amount of work involved in installation and increases the reliability of the system.

NEW!

Page 4: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

LEADING TECHNICAL PERFORMANCE

Outdoor Units – RMXS48LVJUModel Name RMXS48LVJUNominal Capacity (Cooling / Heating) Btu/h 48,000 / 54,000

SEER / HSPFNon Ducted 18.8 / 11.3Mixed 16.5/10.5Ducted 14.1/9.6

EER / COPNon Ducted 10.3/3.0Mixed 9.8/2.9Ducted 9.3/2.7

Power Supply 208/230V - 1Ø - 60Hz Minimum Circuit Amps A 27.0Maximum Overcurrent Protection A 30.0Sound Pressure - (Cooling/Heating) dB(A) 56/58Connection Ratio (Max Capacity for BPMKS Boxes) 50 - 130%Number of Connectable Indoor Units 2 to 8Number of Connectable BP Units 1 to 3Total System Piping Length ft. (m) 440 (135)Max. Piping Length(OU to BP Box) ft. (m) 180 (55)Max. Piping Length(IU to BP Box) ft. (m) 49 (15)Total Piping Length (OU to BP Box) ft. (m) 180 (55)Total Piping Length (BP to IU) ft. (m) 262 (80)Max. Piping Height (OU to IU) ft. (m) 98 (30)Max. Piping Height (IU to BP Box) ft. (m) 98 (30)Max. Piping Height (BP to BP Box) ft. (m) 49 (15)Piping Connection Kit KHRP26A22TOperating Range – (Cooling/Heating) °F DB 23 – 115/5 - 75Dimensions (H x W x D) in. 52-15/16 x 35-7/16 x 12-5/8Net Weight lbs. 283.0

BP UnitsModel Name BPMKS048A2U BPMKS049A3U

Power Supply Single phase 60Hz 208/230VPower Consumption W 10 10Running Current A 0.05 0.05Sound Pressure - (Cooling/Heating) dB(A) 32/32 32/32Number of Connectable Indoor Units 1 to 2 1 to 3Min. Connection Combination 7,000 7,000Max. Connection Combination 48,000 62,000

Piping Connections (O.D.)

LiquidOutdoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3Indoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3Connection Type Flare Flare

GasOutdoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3Indoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3Connection Type Flare Flare

Dimensions (H x W x D) in. 7-1/16 x 11-9/16 x 13-3/4Net Weight lbs. 18.0 20.0

Nominal Conditions:Cooling ModeIndoor: 80 °F DB / 67 °F WBOutdoor: 95 °F DBPipe Length: 25 ft.Level Difference: 0 ft.

Heating ModeIndoor: 70 °F DBOutdoor: 47 °F DB / 43 °F WBPipe Length: 25 ft.Level Difference: 0 ft.

Note:Specifications are subject to change without notice.

Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted UnitsModel Name CTXS07LVJU CTXS09HVJU CTXS12HVJU FTXS15LVJU FTXS18LVJU FTXS24LVJUAirflow-Wet (H/M/L/SL) CFM 332/261/194/145 388/335/283/- 388/335/283/- 568/477/385/360 583/484/385/360 643/494/350/328Airflow-Dry (H/M/L/SL) CFM 350/290/233/219 400/357/314/- 400/357/314/- 593/505/417/371 625/526/431/399 699/572/445/403Sound Pressure - Cooling (H/M/L/SL) dB(A) 38/32/25/22 44/40/35/- 45/41/36/- 45/40/35/32 46/41/36/33 51/44/37/34Sound Pressure - Heating (H/M/L/SL) dB(A) 38/33/28/25 44/39/34/- 45/40/35/- 43/38/33/30 45/40/35/32 48/42/37/34

Piping ConnectionsLiquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 5/8Condensate Drain Connection (O.D.) in. Ø 5/8 Ø 11/16 Ø 11/16 Ø 5/8 Ø 5/8 Ø 5/8

Dimensions (H x W x D) in. 11-5/8 x 31-1/2 x 8-7/16 11-7/16 x 31-5/16 x 9-3/8 13-3/8 x 41-5/8 x 9-3/4 Net Weight lbs. 20.0 20.0 20.0 31.0 31.0 31.0

Indoor Units - FDXS_LVJU and CDXS_LVJU Slim Duct UnitsModel Name FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU External Static Pressure "W.G. 0.12 0.12 0.16 0.16 0.16Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297Sound Pressure - Cooling (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31 Sound Pressure - Heating (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31

Piping ConnectionsLiquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 1/2Condensate Drain in. Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32

Dimensions (H x W x D) in. 7-7/8 x 27-9/16 x 24-7/16 7-7/8x35-7/16x24-7/16 Net Weight lbs. 47.0 47.0 60.0 60.0 60.0

Indoor Units - FFQ_LVJU 2’x2’Duct UnitsModel Name FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU Airflow Rate (H/L) CFM 318/230 353/230 424/283 530/353Sound Pressure - Cooling (H/L) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 Sound Pressure - Heating (H/L dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31

Piping ConnectionsLiquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2Condensate Drain (O.D.) in. Ø 1-1/32 Ø 1-1/32 Ø 1-1/32 Ø 1-1/32

Dimensions – Unit (H x W x D) in. 11-1/4 x 22-5/8 x 22-5/8Dimensions – Deco Panel (H x W x D) in. 2-1/4 x 27-5/8 x 27-5/8Net Weight lbs. 38.5 38.5 38.5 38.5

0.6‐Ton 0.75‐Ton 1.0‐Ton 1.25‐Ton 1.5‐Ton 2.0‐Ton

Up to 2 Zones Up to 3 Zones

Up to 8 indoor units can be      connected to a single outdoor unit

A High Efficiency solution with optimum flexibility to provide zoning for with the connection of up to 8 indoor units utilizing long pipe lengths, ease of installation with standardized line‐sets, simplified electrical requirements  and staged installations

Page 5: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

TIME‐SAVING INSTALLATION AND EASELonger Refrigerant Piping

Simplified Electrical Wiring

The outdoor unit and BP units operate from separate 208/230V single‐phase power supplies.  Indoor units are powered from the BP unit and wired as Daikin’s current 4 wire single split systems reducing the wiring size and easing installation

More than 60% in physical space savingsMore than 80% in total (including clearances) space savings

Space Saving Design

Traditional Outdoor Unit

Daikin RMXS

35‐7/16”

12‐5/8”

35‐1/8”

38‐11/16”

Installation Space

Piping Requirements Allowable Length Details

Maximum allowable length

Between outdoor and BP units Total piping length Piping length between outdoor and BP units ≤ 180 ft (55 m) - [Example] a+b+c+d+e ≤ 180 ft

Between BP and indoor units Total piping length Piping length between BP and indoor units: 262 ft (80 m) - [Example] f+g+h+i+j+k+l ≤ 262ft

Between BP and indoor unit 1 room length Piping length between BP and indoor unit ≤ 49 ft (15 m) - [Example] f, g, h, i, j, k, l ≤ 49 ft

Allowable height

Between outdoor and indoor units

Difference in height

Difference in height between outdoor and indoor units (H1) ≤ 98 ft (30 m)

Between outdoor and BP units Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)

Between BP and BP units Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)

Between indoor and indoor units Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)

Minimum allowable length Piping lengthPipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft

Allowable length after the REFNET branch Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m)[Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft

Additional refrigerant calculation

Longer refrigerant piping capabilities offers  much more flexibility in the choice of installation positions for the indoor units, and greatly simplifies system layout.

Page 6: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Distributor or Dealer Information: Daikin AC (Americas), Inc.1645 Wallace Drive, Suite 110

Carrollton, TX 75006www.daikinac.com

866.4DAIKIN972.245.1510

For all equipment installation & application limitations please refer to the specific Engineering Data Books.Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.

www.likin-daikin.com

• Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

• Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

• Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

For any inquiries, contact your local Daikin sales office.

WARNINGS:

© 2013 Daikin Industries, Limited.Daikin, Daikin AC Absolute Comfort, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD.

Use of the AHRI Certified™ mark indicates a manufacturer'sparticipation in the certification program. For verification of

certification for individual products, go to www.ahridirectory.org

PFSMPUSE13-01R

System Operation RangeCooling Operation 23 °FDB – 115 °FDB                  

Ambient Temperature

57 °FWB – 82 °FDB                Indoor Room Temperature

Heating Operation 5 °FDB – 60 °FWB          Ambient Temperature

50 °FDB – 82 °FDB Indoor Room Temperature

Note: No low ambient option exists with this product line.

Page 7: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Sales Bulletin #MS004 Date: January 15, 2013

To: Daikin Sales, Service, and Distribution

Subject: New 4-Ton 8 Zone Super Multi PLUS System (RMXS) and New Multi-Split Indoor

Units

Daikin AC is pleased to introduce the new 8 Zone Super Multi PLUS System targeting residential and light commercial markets. The Super Multi PLUS complements and expands our current multi-split portfolio and provides superior efficiency and flexibility with the ability to connect 2 to 8 indoor units from a variety of indoor unit options including Daikin’s new 2’ X 2’ ceiling cassette units (9 – 18 MBH), wall mounted units (7 MBH – 24 MBH), and new extended range of slim duct units (9 – 24 MBH).

Product Overview

The Super Multi PLUS system is available from April 2013 and the launch will include the following new models: -

RMXS48LVJU 4.0 Ton Super Multi PLUS Condensing Unit BPMKS048A2U 2 Zone Branch Provider Box BPMKS049A3U 3 Zone Branch Provider Box CDXS24LVJU 2.0 Ton Slim Duct Built-in Unit FFQ09LVJU 0.75 Ton 2’ X 2’ Ceiling Cassette Unit FFQ12LVJU 1.0 Ton 2’ X 2’ Ceiling Cassette Unit FFQ15LVJU 1.25 Ton 2’ X 2’ Ceiling Cassette Unit FFQ18LVJU 1.5 Ton 2’ X 2’ Ceiling Cassette Unit

Daikin AC’s new Branch Provider (BP) unit allows the Super Multi PLUS to connect from 2 to 8 indoor units with indoor unit capacities up to 130% (62,000 Btu/h) of the outdoor unit.

Daikin AC ( A merica s) , Inc. 1645 W allace Drive , Sui t e 110

Page 8: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Carrol l ton , T X 75006 972-245-1510

www.daikinac.com

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 2 of 10 Product Information

The new Super Multi can serve up to 8 rooms with the addition of indoor units extending our current range of indoor unit availability to include a total of 15 models in 3 different types for design flexibility with individual comfort control.

Product class leading efficiency levels (4-Ton Multi-Split Heat Pump) are available with ratings up to SEER 18.8 for non-ducted combinations and up to HSPF 11.3.

2’ X 2’ Ceiling Cassette (New)

To meet the growing demand of the market and to satisfy the requests of customers, Daikin AC is pleased to introduce the new 2’ X 2’ ceiling cassette, FFQ_LVJU, for multi- split systems only to complement our current range of indoor units. These units provide customizable comfort with four-way directional airflow and easy adjustments for corner or corridor installation. Compact with an easy-to-clean grille and sophisticated decoration panel, these units are designed to fit nearly flush with or into a standard ceiling tile for an unobtrusive interior finish. Ideal for both residential and light commercial applications, the 2’ X 2’ is great for new or retrofit homes, offices, and retail spaces.

The 2’ X 2’ is compatible with the new Navigation Remote Controller BRC1E72. The configurable display offers 3 options with an advanced display great for residential applications and a simplified display ideal for applications such as hotels wanting to only provide the necessary buttons to users for comfort without confusion. Refer to Sales Bulletin #CT013 for more information.

Wall Mount (Extended Range) and Slim Duct (New) Units

Page 9: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

The new slim duct, CDXS24LVJU, and addition of the current LV-Series wall mount, FTXS24LVJU, extends the indoor unit capacity range up to 24 MBH, enhancing the versatility of the Super Multi and offering solutions for larger spaces having more cooling or heating requirements. Indoor units are provided with a wireless controller as standard or can be utilized with the new optional Daikin ENVi controller for smart comfort available April 2013 (more information to come at the end of January). Please note indoor units in 24 MBH capacities are only available with the Super Multi PLUS.

Branch Provider (BP) Unit

The BPMKS Branch Provider boxes allow indoor units of different capacities to be connected and then vary refrigerant volume to meet cooling and heating requirements of individual room zones. Available in 2 and 3 port units, up to 3 BP units can be connected to the Super Multi PLUS for initial full system integration or phased installation. To simplify installation the BP boxes come with flare connections removing the need for brazing at the box location.

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 3 of 10 Technical Specifications

Outdoor Units BP Units

Page 10: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Indoor Units

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 4 of 10 Piping Limitations

Page 11: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Piping Requirements Branch with REFNET Joint Maximum allowable length

Between outdoor and BP units

Total piping length

Piping length between outdoor and BP units ≤ 180 ft (55 m) [Example] a+b+c+d+e ≤ 180 ft

Between BP and indoor units

Total piping length

Piping length between BP and indoor units: 262 ft (80 m) [Example] f+g+h+i+j+k+l ≤ 262ft

Between BP and indoor unit

1 room length

Piping length between BP and indoor unit ≤ 49 ft (15 m) [Example] f, g, h, i, j, k, l ≤ 49 ft

Allowable height

Between outdoor and indoor units

Difference in height

Difference in height between outdoor and indoor units (H1) ≤ 98 ft (30 m)

Between outdoor and BP units

Difference in height

Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)

Between BP and BP units

Difference in height

Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)

Between indoor and indoor units

Difference in height

Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)

Minimum allowable length Piping

length Pipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft

Allowable length after the REFNET branch

Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m) [Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft

Additional refrigerant calculation

Electrical Wiring

The outdoor unit and BP units operate from separate 208/230V single-phase power supplies. Indoor units are powered from the BP unit and

Page 12: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

wired as Daikin’s current 4 wire single split systems reducing the wiring size and easing installation

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 5 of 10 Operation Range

Cooling Operation 23 °FDB – 115 °FDB

Ambient Temperature

57 °FWB – 82 °FDB Indoor Room Temperature

Heating Operation 5 °FDB – 60 °FWB

Ambient Temperature

50 °FDB – 82 °FDB Indoor Room Temperature

Note: No low ambient option exists with this product line.

Competitive Comparison

Technical Specification vs. Competing Manufacturer Manufacturer Daikin AC

RMXS48LVJU Company M Company F Company L Nominal Cooling Capacity Btu/h 48,000 48,000 48,000 54,000 Maximum Cooling Capacity Btu/h 54,000 54,000 51,100 63,200 Nominal Heating Capacity at 47 °F Btu/h 54,000 54,000 54,000 58,000 Maximum Heating Capacity at 47 °F Btu/h 61,000 60,000 57,000 64,000

SEER / HSPF

Non Ducted 18.8 / 11.3 15.0 / 8.7 17.0 / 9.8 18.4 / 8.7 Mixed 16.5 / 10.5 14.8 / 8.8 15.8 / 9.5 17.1 / 8.3 Ducted 14.1 / 9.6 14.7 / 8.9 14.7 / 9.3 15.8 / 8.0

EER / COP 47F

Non Ducted 10.3 / 3.0 8.3 / 3.28 9.25 / - 10.3 / 3.1 Mixed 9.8 / 2.9 7.8 / 3.14 8.97 / - n/a Ducted 9.3 / 2.7 7.4 / 3.00 8.70 / - n/a

Maximum Overcurrent Protection MOP (A) 30A 50A 40A N/A Minimum Circuit Amps MCA (A) 27A 32A N/A N/A Connected Capacity % 50 – 130 22 - 130 80 - 130 * - 135

Page 13: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Connectable Indoor Capacity Btu/h 24,000 - 62,400 70,200 62,000 73,000 Cooling Operating Range °F DB 23 – 115 23 – 115 23 – 115 14 – 118.4 Heating Operating Range °F DB 5 – 75 5 – 70 5 – 75 0 – 75

Max. Pipe Length ft

Total 433.0 377.0 377.0 475.7 OU to IU 230.0 230.0 180.0 295.3 Box to IU 49.0 49.0 49.0 49.2

Max Pipe Height Difference ft

OU to Box 98.0 49.0 98.0 n/a IU to IU 49.0 39.0 49.0 49.2 OU to IU 98.0 98.0 98.0 98.4

Indoor Unit Availability Indoor Type Wall Mounted Duct Mounted 2’ X 2’ 4 Way Ceiling Cassette Capacity (MBH) 07 09 12 15 18 24 09 12 15 18 24 09 12 15 18 24 Daikin AC ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Company M ● ● ● ● ● ● ● ● ● ● ● ● ● Company L ● ● ● ● ● ● ● ● Company F ● ● ● ● ● ● ● ● ● ● ● ● ●

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 6 of 10

Product and Document Availability

Product and Documentation January February March April

TRL Pricing

Sales Presentation

Submittal Data Sheets

Engineering Data Book

Installation & Operations Manual

Product Flyer

General Catalogue

Sales Availability

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 7 of 10

Page 14: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating

Capacity(kBT U/h)

Power Consumption

(kW) 43.2 90.0% 49.0 4.80 43.7 91.0% 49.5 4.85 44.2 92.0% 50.0 4.90 44.6 93.0% 50.5 4.95 45.1 94.0% 51.0 5.00 45.6 95.0% 51.5 5.05 46.1 96.0% 52.0 5.10 46.6 97.0% 52.5 5.15 47.0 98.0% 53.0 5.20 47.5 99.0% 53.5 5.24 48.0 100.0% 54.0 5.27 48.5 101.0% 54.1 5.28 49.0 102.0% 54.1 5.28 49.4 103.0% 54.2 5.28 49.9 104.0% 54.2 5.28 50.4 105.0% 54.3 5.29 50.9 106.0% 54.3 5.29 51.4 107.0% 54.4 5.29 51.8 108.0% 54.4 5.29 52.3 109.0% 54.5 5.29 52.8 110.0% 54.5 5.30 53.3 111.0% 54.6 5.30 53.8 112.0% 54.6 5.30 54.2 113.0% 54.7 5.30 54.7 114.0% 54.7 5.30 55.2 115.0% 54.8 5.31 55.7 116.0% 54.8 5.31 56.2 117.0% 54.9 5.31 56.6 118.0% 54.9 5.31 57.1 119.0% 55.0 5.31 57.6 120.0% 55.0 5.32 58.1 121.0% 55.1 5.32 58.6 122.0% 55.1 5.32 59.0 123.0% 55.2 5.32 59.5 124.0% 55.2 5.32 60.0 125.0% 55.3 5.33 60.5 126.0% 55.3 5.33 61.0 127.0% 55.4 5.33 61.4 128.0% 55.4 5.33 61.9 129.0% 55.5 5.33 62.0 129.2% 55.5 5.34

Appendix – System Capacity Details versus Combination Ratio Connected

Heating (60 Hz 230/208V) with Ducted Indoor Units

Total Indoor

Unit Capacity (kBTU/h)

Combination

(%) Heating

Capacity(kBT U/h)

Power Consumption

(kW) 24.0 50.0% 29.0 2.58 24.5 51.0% 29.5 2.62 25.0 52.0% 30.0 2.68 25.4 53.0% 30.5 2.74 25.9 54.0% 31.0 2.80 26.4 55.0% 31.5 2.86 26.9 56.0% 32.0 2.92 27.4 57.0% 32.5 2.98 27.8 58.0% 33.0 3.04

Page 15: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

28.3 59.0% 33.5 3.10 28.8 60.0% 34.0 3.16 29.3 61.0% 34.5 3.21 29.8 62.0% 35.0 3.27 30.2 63.0% 35.5 3.33 30.7 64.0% 36.0 3.39 31.2 65.0% 36.5 3.45 31.7 66.0% 37.0 3.50 32.2 67.0% 37.5 3.56 32.6 68.0% 38.0 3.62 33.1 69.0% 38.5 3.67 33.6 70.0% 39.0 3.73 34.1 71.0% 39.5 3.79 34.6 72.0% 40.0 3.84 35.0 73.0% 40.5 3.90 35.5 74.0% 41.0 3.95 36.0 75.0% 41.5 4.01 36.5 76.0% 42.0 4.06 37.0 77.0% 42.5 4.12 37.4 78.0% 43.0 4.17 37.9 79.0% 43.5 4.22 38.4 80.0% 44.0 4.28 38.9 81.0% 44.5 4.33 39.4 82.0% 45.0 4.38 39.8 83.0% 45.5 4.44 40.3 84.0% 46.0 4.49 40.8 85.0% 46.5 4.54 41.3 86.0% 47.0 4.59 41.8 87.0% 47.5 4.64 42.2 88.0% 48.0 4.70 42.7 89.0% 48.5 4.75

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 8 of 10

Page 16: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating

Capacity(kBT U/h)

Power Consumption

(kW) 43.2 90.0% 49.0 3.67 43.7 91.0% 49.5 3.70 44.2 92.0% 50.0 3.74 44.6 93.0% 50.5 3.77 45.1 94.0% 51.0 3.81 45.6 95.0% 51.5 3.84 46.1 96.0% 52.0 3.87 46.6 97.0% 52.5 3.91 47.0 98.0% 53.0 3.94 47.5 99.0% 53.5 3.98 48.0 100.0% 54.0 3.98 48.5 101.0% 54.1 3.99 49.0 102.0% 54.2 3.99 49.4 103.0% 54.3 4.00 49.9 104.0% 54.4 4.00 50.4 105.0% 54.5 4.01 50.9 106.0% 54.6 4.01 51.4 107.0% 54.7 4.02 51.8 108.0% 54.8 4.02 52.3 109.0% 54.9 4.02 52.8 110.0% 55.0 4.03 53.3 111.0% 55.1 4.03 53.8 112.0% 55.2 4.04 54.2 113.0% 55.3 4.04 54.7 114.0% 55.4 4.04 55.2 115.0% 55.5 4.05 55.7 116.0% 55.6 4.05 56.2 117.0% 55.7 4.05 56.6 118.0% 55.8 4.06 57.1 119.0% 55.9 4.06 57.6 120.0% 56.0 4.06 58.1 121.0% 56.1 4.06 58.6 122.0% 56.2 4.07 59.0 123.0% 56.3 4.07 59.5 124.0% 56.4 4.07 60.0 125.0% 56.5 4.08 60.5 126.0% 56.6 4.08 61.0 127.0% 56.7 4.08 61.4 128.0% 56.8 4.08 61.9 129.0% 56.9 4.08 62.0 129.2% 57.0 4.09

Heating (60 Hz 230/208V) with Wall Mounted Indoor Units

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating

Capacity(kBT U/h)

Power Consumption

(kW) 24.0 50.0% 29.0 2.13 24.5 51.0% 29.5 2.17 25.0 52.0% 30.0 2.21 25.4 53.0% 30.5 2.25 25.9 54.0% 31.0 2.30 26.4 55.0% 31.5 2.34 26.9 56.0% 32.0 2.38 27.4 57.0% 32.5 2.42 27.8 58.0% 33.0 2.46 28.3 59.0% 33.5 2.50 28.8 60.0% 34.0 2.54 29.3 61.0% 34.5 2.58

Page 17: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

29.8 62.0% 35.0 2.62 30.2 63.0% 35.5 2.66 30.7 64.0% 36.0 2.70 31.2 65.0% 36.5 2.74 31.7 66.0% 37.0 2.78 32.2 67.0% 37.5 2.82 32.6 68.0% 38.0 2.86 33.1 69.0% 38.5 2.90 33.6 70.0% 39.0 2.93 34.1 71.0% 39.5 2.97 34.6 72.0% 40.0 3.01 35.0 73.0% 40.5 3.05 35.5 74.0% 41.0 3.09 36.0 75.0% 41.5 3.12 36.5 76.0% 42.0 3.16 37.0 77.0% 42.5 3.20 37.4 78.0% 43.0 3.24 37.9 79.0% 43.5 3.27 38.4 80.0% 44.0 3.31 38.9 81.0% 44.5 3.35 39.4 82.0% 45.0 3.38 39.8 83.0% 45.5 3.42 40.3 84.0% 46.0 3.46 40.8 85.0% 46.5 3.49 41.3 86.0% 47.0 3.53 41.8 87.0% 47.5 3.56 42.2 88.0% 48.0 3.60 42.7 89.0% 48.5 3.63

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 9 of 10

Page 18: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating Capacity (kBTU/h)

Power Consumption

(kW) 43.2 90.0% 43.2 4.39 43.7 91.0% 43.7 4.47 44.2 92.0% 44.2 4.55 44.6 93.0% 44.6 4.63 45.1 94.0% 45.1 4.71 45.6 95.0% 45.6 4.79 46.1 96.0% 46.1 4.88 46.6 97.0% 46.6 4.96 47.0 98.0% 47.0 5.04 47.5 99.0% 47.5 5.13 48.0 100.0% 48.0 5.13 48.5 101.0% 48.1 5.14 49.0 102.0% 48.2 5.15 49.4 103.0% 48.3 5.15 49.9 104.0% 48.4 5.16 50.4 105.0% 48.5 5.16 50.9 106.0% 48.6 5.17 51.4 107.0% 48.7 5.17 51.8 108.0% 48.8 5.18 52.3 109.0% 48.9 5.18 52.8 110.0% 49.0 5.19 53.3 111.0% 49.1 5.19 53.8 112.0% 49.2 5.20 54.2 113.0% 49.3 5.20 54.7 114.0% 49.4 5.21 55.2 115.0% 49.5 5.21 55.7 116.0% 49.6 5.22 56.2 117.0% 49.7 5.22 56.6 118.0% 49.8 5.23 57.1 119.0% 49.9 5.23 57.6 120.0% 50.0 5.24 58.1 121.0% 50.1 5.24 58.6 122.0% 50.2 5.25 59.0 123.0% 50.3 5.25 59.5 124.0% 50.4 5.26 60.0 125.0% 50.5 5.26 60.5 126.0% 50.6 5.27 61.0 127.0% 50.7 5.27 61.4 128.0% 50.8 5.28 61.9 129.0% 50.9 5.28 62.0 129.2% 51.0 5.28

Cooling (60 Hz 230/208V) with Ducted Indoor Units

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating Capacity (kBTU/h)

Power Consumption

(kW) 24.0 50.0% 24.0 1.92 24.5 51.0% 24.5 1.97 25.0 52.0% 25.0 2.01 25.4 53.0% 25.4 2.06 25.9 54.0% 25.9 2.11 26.4 55.0% 26.4 2.16 26.9 56.0% 26.9 2.21 27.4 57.0% 27.4 2.26 27.8 58.0% 27.8 2.31 28.3 59.0% 28.3 2.36 28.8 60.0% 28.8 2.42 29.3 61.0% 29.3 2.47

Page 19: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

29.8 62.0% 29.8 2.53 30.2 63.0% 30.2 2.58 30.7 64.0% 30.7 2.64 31.2 65.0% 31.2 2.70 31.7 66.0% 31.7 2.75 32.2 67.0% 32.2 2.81 32.6 68.0% 32.6 2.87 33.1 69.0% 33.1 2.93 33.6 70.0% 33.6 2.99 34.1 71.0% 34.1 3.06 34.6 72.0% 34.6 3.12 35.0 73.0% 35.0 3.18 35.5 74.0% 35.5 3.25 36.0 75.0% 36.0 3.31 36.5 76.0% 36.5 3.38 37.0 77.0% 37.0 3.45 37.4 78.0% 37.4 3.51 37.9 79.0% 37.9 3.58 38.4 80.0% 38.4 3.65 38.9 81.0% 38.9 3.72 39.4 82.0% 39.4 3.79 39.8 83.0% 39.8 3.87 40.3 84.0% 40.3 3.94 40.8 85.0% 40.8 4.01 41.3 86.0% 41.3 4.09 41.8 87.0% 41.8 4.16 42.2 88.0% 42.2 4.24 42.7 89.0% 42.7 4.32

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)

Page 10 of 10

Page 20: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating

Capacity(kBT U/h)

Power Consumption

(kW) 43.2 90.0% 43.2 3.91 43.7 91.0% 43.7 3.98 44.2 92.0% 44.2 4.05 44.6 93.0% 44.6 4.13 45.1 94.0% 45.1 4.20 45.6 95.0% 45.6 4.28 46.1 96.0% 46.1 4.35 46.6 97.0% 46.6 4.43 47.0 98.0% 47.0 4.51 47.5 99.0% 47.5 4.59 48.0 100.0% 48.0 4.64 48.5 101.0% 48.2 4.65 49.0 102.0% 48.5 4.67 49.4 103.0% 48.7 4.69 49.9 104.0% 48.9 4.71 50.4 105.0% 49.1 4.73 50.9 106.0% 49.3 4.75 51.4 107.0% 49.5 4.77 51.8 108.0% 49.7 4.79 52.3 109.0% 49.9 4.81 52.8 110.0% 50.0 4.82 53.3 111.0% 50.2 4.84 53.8 112.0% 50.4 4.85 54.2 113.0% 50.5 4.87 54.7 114.0% 50.7 4.88 55.2 115.0% 50.8 4.90 55.7 116.0% 50.9 4.91 56.2 117.0% 51.1 4.92 56.6 118.0% 51.2 4.94 57.1 119.0% 51.3 4.95 57.6 120.0% 51.4 4.96 58.1 121.0% 51.5 4.97 58.6 122.0% 51.6 4.98 59.0 123.0% 5.7 4.99 59.5 124.0% 51.8 4.99 60.0 125.0% 51.8 5.00 60.5 126.0% 51.9 5.01 61.0 127.0% 52.0 5.01 61.4 128.0% 52.0 5.02 61.9 129.0% 52.1 5.02 62.0 129.2% 52.1 5.03

Cooling (60 Hz 230/208V) with Wall Mounted Indoor Units

Total Indoor Unit Capacity

(kBTU/h)

Combination

(%) Heating

Capacity(kBT U/h)

Power Consumption

(kW) 24.0 50.0% 24.0 1.78 24.5 51.0% 24.5 1.81 25.0 52.0% 25.0 1.85 25.4 53.0% 25.4 1.89 25.9 54.0% 25.9 1.92 26.4 55.0% 26.4 1.96 26.9 56.0% 26.9 2.00 27.4 57.0% 27.4 2.04 27.8 58.0% 27.8 2.09 28.3 59.0% 28.3 2.13 28.8 60.0% 28.8 2.17 29.3 61.0% 29.3 2.22

Page 21: 4 Ton 8 Zone Multi Split Heat Pump System - Ductless AC · PDF fileDESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models

29.8 62.0% 29.8 2.26 30.2 63.0% 30.2 2.31 30.7 64.0% 30.7 2.35 31.2 65.0% 31.2 2.40 31.7 66.0% 31.7 2.45 32.2 67.0% 32.2 2.50 32.6 68.0% 32.6 2.55 33.1 69.0% 33.1 2.60 33.6 70.0% 33.6 2.66 34.1 71.0% 34.1 2.71 34.6 72.0% 34.6 2.76 35.0 73.0% 35.0 2.82 35.5 74.0% 35.5 2.88 36.0 75.0% 36.0 2.93 36.5 76.0% 36.5 2.99 37.0 77.0% 37.0 3.05 37.4 78.0% 37.4 3.11 37.9 79.0% 37.9 3.17 38.4 80.0% 38.4 3.24 38.9 81.0% 38.9 3.30 39.4 82.0% 39.4 3.36 39.8 83.0% 39.8 3.43 40.3 84.0% 40.3 3.49 40.8 85.0% 40.8 3.56 41.3 86.0% 41.3 3.63 41.8 87.0% 41.8 3.70 42.2 88.0% 42.2 3.76 42.7 89.0% 42.7 3.84

Published by Daikin AC Product Marketing Department

(Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without

notice and without incurring any obligation.)