15
29 Cable & Pipe Tracers & Fault Locators Electrical Testers PAT Testers & RCD Testers Micro-Ohm Meters & Earth Testers Power Analysers & Recorders AC Electrical Chart Recorders Current Clamps Probes & Accessories Insulation Testers & Meggers to 20kV Oil, Hipot & VLF Testers above 20kV Power Transformer Testers Current Injectors Protection Relay Testing Systems AC Sources/Inverters/Generators Power Transformers Power Line Conditioners/UPS Battery Management Systems See also Ground Penetrating Radar on page 67 See also Oil, Hipot & VLF testers above 20kV on page 39 & 40 See also Underground Services Location on page 66 & 67 CScope CATXDSGV-KIT Cable and Pipe Locator CSC,CATXDSGV-KIT (3664) AU/MY Cable location tool. Includes 33kHz generator with touch button controls and LCD, XD receiver/locator with 33kHz, power or radio modes. Direct connec- tion cable, stake and 75mm tong set. The trans- mitter can operate with direct connection, tongs or induction. Will also determine cable depth, range 0.2m to 3m. It will operate with the Radiodetection 33kHz sondes. Fluke Cable Locator FLU,2042 (3625) AU General purpose cable locator. Ideal for tracing cables in walls and underground, locating fuses/ breakers on final circuits and locating interruptions and short-circuits in cables and electrical floor heating systems. Can also be used for tracing metallic water and heating pipes. Supplied as a complete kit comprising of a transmitter and receiver in a purpose-made carry case. The receiver also incorporates a torch function for working in dimly lit locations. Cable & Pipe Tracers & Fault Locators cont’d. Megger MPP1002 Cable Fault Pinpoint Locator MEG,MPP1002-FAULT PP (3626) AU Pinpoints faults in shielded and direct buried primary cables via a single Geophone or dual Geophone probe. Stand-alone unit (without probes) measures electromagnetic surge and supplies the amplitude of that surge which aids in finding the fault. The versions can successfully detect both the electromagnetic and acoustic pulses emitted from an arcing fault when it is surged. Can be used with any Megger PFL Power Cable Fault Locating system (or) any surge generator. Fault detection up to 23m away and extended battery life, ballistic pulse scale provides thump magnitude and surge period, background interference elimination via selectable acoustic frequency band. Megger TDR1000 TDR Cable Fault Locator MEG,TDR1000 (3636) AU For cable consisting of 2 insulated metallic elements, one of which may be the armouring or screen of the cable. Internal matching networks to allow testing of 25, 50, 75 & 100 cables. Can be matched to the cable using the balance control allowing long lengths of cable to be easily tested and faults close to the instrument to be seen. Propagation velocity value can be similarly adjusted to match the cable, ensuring an accurate distance measurement can be directly read. Gain of the instrument is also variable, allowing more minor faults to be identified over length of the cable. Range 10m to 3km. Display: Large high-resolution backlit [LCD]. Batteries 6 x LR6 (AA), alkaline, NiCd or NiMH cells. 20/30h continuous use depending on backlight use. Dust and shower proof to IP54. Megger TDR20002RM Dual Channel TDR Cable Fault Locator MEG,TDR2000/2RM (3624) AU Range 20km at VF =0.90. Backlit display, dual cursor measurement, output pulse amplitude and width control. No blocking filter required for direct connection to live systems up to 300VAC. 15 memory trace storage, down loadable to PC via RS232C interface, software supplied. Ranges 50m, 100m, 200m, 400m, 1km, 2km, 4km, 8 km & 16km. Resolution 0.1m up to 200m, 0.2m up to 400m, 0.1% of range above 400m. Measurement accuracy 0.1% of range. Input impedance 120. Velocity factor variable from 0.300 to 0.999 in steps of 0.001. Powered via rechargeable NiMH powerpack, charger supplied. Radiodetection Stethoscope Antenna for RAD,RD400 Series RAD,STETH-L (3634) AU Concave head fitted to flexible goose neck with handle. Length 480mm, head 46mmØ. Frequency range 50Hz to 65kHz. Connect to any RD400 series Radio detection receiver fitted with accessory socket. Electrical Testers See also Current Clamps Probes & Accessories on page 36-38 AVO Penta-Plus DMM Analyser AVO,PENTA-PLUS-DMM (8470) AU Multifunction meter for measuring 1 & 3ph Volts AC, primary and secondary current, true and reactive power, amplitude and phase angle, and also frequency. Easily configured to measure the amplitude and phase angle between any 2 current or voltage inputs. Displayed simultaneously on a backlight graphic LCD screen. Internal memory records up to 60 test results. Logging via RS232C port. Parallel printer port. Voltage 0 to 650VAC, 9 ranges with 0.1% resolution. Max 1kV. Current 0 to 100A AC in 11 ranges, with 0.1% resolution. Phase angle 0 to 360° with 0.1° resolution. Power true and reactive ±0 to 100kW & ±0 to 100kVAr. Frequency 45 to 65Hz. Timer 0 to 999.999 seconds. Line or battery operated, 3h continuous operation on full charge. Cable & Pipe Tracers & Fault Locators ELECTRICAL POWER www.techrentals.com.au Save your time and reduce your real costs. Find out all about our Conguration and Download solutions on page 11.

4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

29

Cable & Pipe Tracers & Fault LocatorsElectrical TestersPAT Testers & RCD TestersMicro-Ohm Meters & Earth TestersPower Analysers & RecordersAC Electrical Chart RecordersCurrent Clamps Probes & AccessoriesInsulation Testers & Meggers to 20kVOil, Hipot & VLF Testers above 20kVPower Transformer TestersCurrent InjectorsProtection Relay Testing SystemsAC Sources/Inverters/GeneratorsPower TransformersPower Line Conditioners/UPSBattery Management Systems

See also Ground Penetrating Radar on page 67 See also Oil, Hipot & VLF testers above 20kV on page 39 & 40 See also Underground Services Location on page 66 & 67

CScope CATXDSGV-KIT Cable and Pipe LocatorCSC,CATXDSGV-KIT (3664) AU/MYCable location tool. Includes 33kHz generator with touch button controls and LCD, XD receiver/locator with 33kHz, power or radio modes. Direct connec-tion cable, stake and 75mm tong set. The trans-mitter can operate with direct connection, tongs or induction. Will also determine cable depth, range 0.2m to 3m. It will operate with the Radiodetection 33kHz sondes.

Fluke Cable LocatorFLU,2042 (3625) AUGeneral purpose cable locator. Ideal for tracing cables in walls and underground, locating fuses/breakers on final circuits and locating interruptions and short-circuits in cables and electrical floor heating systems. Can also be used for tracing metallic water and heating pipes. Supplied as a complete kit comprising of a transmitter and receiver in a purpose-made carry case. The receiver also incorporates a torch function for working in dimly lit locations.

Cable & Pipe Tracers & Fault Locators cont’d.

Megger MPP1002 Cable Fault Pinpoint LocatorMEG,MPP1002-FAULT PP (3626) AU

Pinpoints faults in shielded and direct buried primary cables via a single Geophone or dual Geophone probe. Stand-alone unit (without probes) measures electromagnetic surge

and supplies the amplitude of that surge which aids in finding the fault. The versions can successfully detect both the electromagnetic and acoustic pulses emitted from an arcing fault when it is surged. Can be used with any Megger PFL Power Cable Fault Locating system (or) any surge generator. Fault detection up to 23m away and extended battery life, ballistic pulse scale provides thump magnitude and surge period, background interference elimination via selectable acoustic frequency band.

Megger TDR1000 TDR Cable Fault LocatorMEG,TDR1000 (3636) AUFor cable consisting of 2 insulated metallic elements, one of which may be the armouring or screen of the cable. Internal matching networks to allow testing of 25, 50, 75 & 100 cables. Can be matched to the cable using the balance control allowing long lengths of cable to be easily tested and faults close to the instrument to be seen. Propagation velocity value can be similarly adjusted to match the cable, ensuring an accurate distance measurement can be directly read. Gain of the instrument is also variable, allowing more minor faults to be identified over length of the cable. Range 10m to 3km. Display: Large high-resolution backlit [LCD]. Batteries 6 x LR6 (AA), alkaline, NiCd or NiMH cells. 20/30h continuous use depending on backlight use. Dust and shower proof to IP54.

Megger TDR20002RM Dual Channel TDR Cable Fault LocatorMEG,TDR2000/2RM (3624) AURange 20km at VF =0.90. Backlit display, dual cursor measurement, output pulse amplitude and width control. No blocking filter required for direct connection to live systems up to 300VAC. 15 memory trace storage, down loadable to PC via RS232C interface, software supplied. Ranges 50m, 100m, 200m, 400m, 1km, 2km, 4km, 8 km & 16km. Resolution 0.1m up to 200m, 0.2m up to 400m, 0.1% of range above 400m. Measurement accuracy 0.1% of range. Input impedance 120. Velocity factor variable from 0.300 to 0.999 in steps of 0.001. Powered via rechargeable NiMH powerpack, charger supplied.

Radiodetection Stethoscope Antenna for RAD,RD400 SeriesRAD,STETH-L (3634) AUConcave head fitted to flexible goose neck with handle. Length 480mm, head 46mmØ. Frequency range 50Hz to 65kHz. Connect to any RD400 series Radio detection receiver fitted with accessory socket.

Electrical Testers See also Current Clamps Probes & Accessories on page 36-38

AVO Penta-Plus DMM AnalyserAVO,PENTA-PLUS-DMM (8470) AUMultifunction meter for measuring 1 & 3ph Volts AC, primary and secondary current, true and reactive power, amplitude and phase angle, and also frequency. Easily configured to measure the amplitude and phase angle

between any 2 current or voltage inputs. Displayed simultaneously on a backlight graphic LCD screen. Internal memory records up to 60 test results. Logging via RS232C port. Parallel printer port. Voltage 0 to 650VAC, 9 ranges with 0.1% resolution. Max 1kV. Current 0 to 100A AC in 11 ranges, with 0.1% resolution. Phase angle 0 to 360° with 0.1° resolution. Power true and reactive ±0 to 100kW & ±0 to 100kVAr. Frequency 45 to 65Hz. Timer 0 to 999.999 seconds. Line or battery operated, 3h continuous operation on full charge.

Cable & Pipe Tracers & Fault Locators

ELECTRICAL POWERwww.techrentals.com.au

Save your time and reduce your real costs. Find out all about our Confi guration and Download solutions on page 11.

Page 2: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

30

Electrical Testers cont’d. CATU C-8-36 Phasing Stick - Two Pole Phase Comparator for Indoor UseCAT,CL-8-36 PH STICK (8728) AUDetects differences in voltage between any two points of an installation indicated by LED’s. It also enables assessment of the order of magnitude

of the residual voltage induced by nearby live lines or circuits, and thus differentiates it from the one provided directly from a high voltage source. Main features are wide range of voltages 2kV to 36kV, high luminosity, compact: 620mm with probes dismounted, high dielectric quality insulating material. Two 1.25m elements with removable probes, connected via a high-insulation lead, maximum use distance: 2.25m (with probe extenders). Operation testing: with a checking device.

Hioki 3283 Clamp on Leak HiTesterHIO,3283 CLAMP ON-LT (8804) AUEasily monitor leak current fluctuations. Wide bandwidth, 5Hz to 15kHz (Waveform output), high-sensitivity with a full scale of 10mA (resolution:10μA). High-accuracy at ±1 %, True RMS measurement, analyser functions, for filtering and output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), effective value rectifier. Frequency characteristics (at AC current /voltage) 40 to 2kHz.

Martindale Phase Sequence & Continuity Indicator 100 to 600V, 50/60HzMAR,PSCI424-585 (1233) AUTester may be used, on 3ph circuits, to check the presence & sequence of the phases. Important on motor circuits as a phase reversal will cause a motors direction to reverse. Tester will give visual indication of loss of phase or an incorrect sequence. Tester is supplied in 2 forms - Probe style, the connection to the tester is via 3 insulated cables to 3 fused test probes, 1 with an insulated crocodile clip. Plug style, a 16A, 4 pin, 3ph & earth, BS4343

plug is fitted to the tester. Use as a socket tester prior to plugging in 3ph equipment. Testers supplied in a plastic wallet, with full instructions. Caution, the unit should be checked for correct operation using a known voltage before use.

PAT Testers & RCD TestersMegger LTW335 Fault Loop Impedance TesterMEG,LTW335-FLIT (2612) AU

2 Wire Non-tripping loop tester. 50V to 440V operation, 110V centre-tap loop testing, CATIV installation testing, AUTO start - operation, 0.01Ω resolution. MaxZ + (R1+R2) + Download.

Megger RCDT330 Residual Current Device TesterMEG,RCDT330 (2618) AUTests standard, DC, selection and programmable RCDs. Ramp testing. Auto (remote) testing. Auto sequence test feature. 3ph safe. Enables testing on 110V centre tapped supplies. Performs 1/2I, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA, 300mA, 500mA & 1,000mA on general and selective (time delayed) RCDs. Weatherproof to IP54. USB interface for test results download.

PAT Testers & RCD Testers cont’d.Metrel IT3017- Installation Tester for Testing to AS/NZS3000

MET,IT3017INSTALTEST (2610) AUMultifunction installation tester with measurement functions and Pass/Fail limits set to AS/NZS3000 Wiring Rules, and

storing of test results for printing compliance test reports. In-built Australian measurements and Pass/Fail limits, and guarantees accountability and traceability with storing of test results. Simply conduct the test, press the Memory button to save the result and assign the result to a location, then download results to PC software and print-out compliance test reports with actual test results. Earth Continuity & Resistance, Insulation Resistance, Polarity, Correct Circuit Connections, Fault Loop Impedance and RCD Testing. “Auto-Sequence Test” mode further speeds up compliance testing and reporting.

Metrel MI 2121 AUS Advanced RCD TesterMET,MI2121AUS (2620) AUExceeds all requirements of AS NZS3760:2003.

Stores upto 1,000 tests. Interface RS232 Software. Fast testing of 10,30, 100, 300, 500, 1,000mA RCD’s both

standard (I, II, III) and selective (IV) AC types. With 50%, 100%, 200% and 500% nominal test current for all ranges. Sinusoidal trip current for reliable operation. Selectable phase angle 0 degree (positive) and 180 degree (negative). Measures RCD trip time and current, phase voltage to 470V. 1,000 test result memory logging. Results download software.

Seaward PAC 3760 Appliance CheckerSEW,PAC3760 (2605) AUPerforms the following tests in conformance to AS/NZS 3760:2000, earth bond, insulation & polarity tests, also leakage current tests for Class I & Class II appliances and leads (leakage current testing of appliances, which requires power to “switch” them on, is the method required by AS/NZS3760: 2003). Simple pass/fail indication. Unique 3 button operation. Class I, class II and leakage current. Automatic test sequence senses an IEC or extension lead then performs a polarity test. Detects that the appliance under test is switched “On”. Earth bond test is set at 10A and is capa-ble of fusing a poor earth.

Seaward ProTag OPTIMA-300 Testing and Tagging SystemSEW,PT-300 (2603) AU

Comprises the Seaward PrimeTest 300 appliance and RCD tester, ProTag Optima test tag printer and the BCS-Blue bar code scanner. Battery powered, weighs around 2kg. Carries out all of the tests required under AS/NZS3760 for appliances and leads, and 30mA RCD tests. Operates as a handheld data logging device by recording any type of test, inspection or risk assessment with user defined inspection routines and an in-built library of measurement and engineering units for recording actual results.

Trolley Suitable for SEW,XE3760PKIT+ Supernova PAT TesterSEW,TROLLEY-3760PKIT (2608) AUTrolley is designed for SEW,XE3760PKIT+. Comes with 4 layer shelving, 5 socket extension board socket 240V/10A, extension cable approximately 25 meters, 2 elastic tie ropes and a plastic bin.

ELECTRICAL POWER www.techrentals.com.au

Page 3: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

31

Micro-Ohm Meters & Earth Testers cont’.

Megger High Accuracy Configurable Diagnostic Earth Tester

MEG,DET2/2 (8412) AUProvides a wide resistance range from 0.010Ω to 19.99kΩ for testing larger or more complex grounding systems and for difficult

testing environments, ±0.5% accuracy and 0.001Ω resolution. Microprocessor control and advanced filtering simplify testing in environments with high levels of interference.

Megger DE20C Digital Earth Test ClampMEG,DET20C (8417) AUMeasures ground resistance from 25mΩ to

1,550Ω. Measures ground leakage current from mA to 35A. Automatic self calibration. Auto ranging. High and low alarms. Large memory. Download to Megger Download Manager. Measures earth resistance in installations such as buildings, pylons and RF transmitter sites. Use for the inspection and verification of lightning protection systems. Large jaw opening.

Megger DET4TC2 Digital Earth Tester With Kit

MEG,DET4TC2 MYMeasurement range of 0.010 to 200kΩ, ground noise voltage measurement from 1V to 100V and ground current from 1mA to 20A. Accurate results can be obtained in electrically noisy environments since it is capable of rejecting noise voltages of 40V peak to

peak and the user can select different test frequencies to minimise the effect of interference. Powered from 8 AA batteries. Supplied with ICLAMP augments the traditional fall-ofpotential measurement method with ART (Attached Rod Technique) which allows electrode testing without disconnection and also leakage current measurements down to 1mA. The VCLAMP enables true stakeless measurements to be made in situations where driving stakes is not practical. Megger DLRO10 Micro-Ohm MeterMEG,DLRO10 (1267) AUSelf contained automatic micro-ohm meter, selecting the most suitable test current, up to 10A DC to measure resistance from 0.1uΩ to 2kΩ on one of seven ranges. Instrument is built into a strong, lightweight case. Light enough to be worn around the neck, small enough to be taken into areas which were previously too small to access. Uses a large, bright 4-1/2-digit LED display. Resolution: 0.1microhms. Battery: rechargeable NiMH, typical life 1,000 tests at full load.

Megger DLRO10X Digital Low Resistance Ohm Meter 10A/0.1μΩ-2KOhmMEG,DLRO10X (1266) AU/MYSelf contained automatic micro-ohm meter, selecting the most suitable test current, up to 10A DC to measure resistance from 0.1μ-2k in seven ranges. Real-time download of results on on-board storage for later review. Automatically detects continuity in potential and current connections. Visible warning of

high voltages present at the terminals. Visible warning of current flowing in the test sample. Multiple operating modes including fully automatic. Alpha-numeric keypad for entering test notes. User selectable high and low limits. Autoranging with manual option.

PAT Testers & RCD Testers cont’d. Seaward Supernova XE3760+ PAT System with Printer and Scanner

SEW,XE3760PKIT+ (2600) AU/MYIncludes results label/tag printer and barcode scanner. Performs all AS/NZS3760: 2001/2003 compliant tests, including class 1 & class 2 leakage current 5mA/1mA, an earth conductor bond test up to 25A at 3V (approx. 100W) and 250VDC MOV insulation

resistance tests. Stores 5,000 tests in internal memory by appliance ID, including test type, detailed results, test time & date, next test due date, site & location. Calibrated resolution better than the required 5% of full scale across all ranges as specified by the Standard. Full QWERTY keyboard, and bar code reader for input. Durable plastic adhesive test label/tags printed to attach to appliances and leads includes user ID (logo optional on request) and test barcode ID, saves transcription. Compatible with Seaward PATGuard plus software package.

Micro-Ohm Meters & Earth TestersCHK LM05 Micro-Ohm Meter 10A CHK,LM05 (1262) AU/MYOperates from internal batteries or external power supply. Maximum test current 10A. Resistance range up to 20Ω with a maximum sensitivity of 1μΩ. Includes power supply/charger, duplex helical test leads, length 2m.

Fluke 1623 KIT GEO Earth Ground TesterFLU,1623-KIT (8435) AUPerforms the following tests: 3 & 4-pole ‘Fall of Potential’ using stakes, 4-pole soil resistivity testing using stakes. Selective testing using 1 clamp and stake. Stakeless testing using 2 clamps only. Measuring range 0.001 to 19.99Ω. Stakeless measurement range 0.001 to 199.9Ω.

Fluke 1625 KIT GEO Earth Ground TesterFLU,1625-KIT (8434) AUPerforms the following tests: 3 & 4-pole ‘Fall of Potential’ using stakes, 4-pole soil resistivity testing using stakes. Selective testing using 1 clamp and stake. Stakeless testing using 2 clamps only. Measuring range 0.001 to 19.99Ω. Stakeless measurement range 0.001 to 199.9. Includes the capability AFC (Automatic Frequency Control), to reduce interference, calculates resistance at 50Hz and has settable limits to allow go/no go testing.

Fluke 1630 Earth Ground ClampFLU,1630-EARTH CLAMP (8443) AUEarth ground loop testing and continuity testing without breaking the circuit. Uses the stakeless testing method; eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. Performs earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons.

Fluke Clamp for Ground Loop Resistance around Power PylonsFLU,EI-162BN (8436) AUSelective clamp for ground loop resistance measurement around power pylons. Inner diameter of the clamp is 320mm. Includes the split core transformer and all necessary adapters/connections for the Fluke 1623 and Fluke 1625.

ELECTRICAL POWERwww.techrentals.com.au

Page 4: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

32

Micro-Ohm Meters & Earth Testers cont’d.

Megger DLRO200 200A Micro-Ohm MeterMEG,DLRO200 (1265) AUTest currents from 10A to 200ADC. 0.1 microohm resolution. Weight 14.5kg On board memory for up to 300 test results and notes. RS232 download of stored results onto PC or printer.

Megger DLRO600 Digital Micro-Ohm Meter - High currentMEG,DLRO600 (1268) AU/MYMeasures resistance between 0.1μΩ and 1Ω, at high currents. Provides test currents from 10A to 600A subject to the load resistance and supply voltage. A large backlit liquid crystal display provides all the information needed to perform a test; all test parameters and measurement results are displayed. Range: 0.1μΩ to 999.9mΩ [subject to supply voltage and load resistance]. Accuracy: Voltage ±0.5% ± 0.1mV. Current ±0.5% ± 0.1A. Resistance: Better than mΩ to 100mΩ. Output Current: [refer to data sheet chart for detail]. Power supply for: full output: 207 to 265V 50/60Hz with a load less than 7Ω including current leads [i.e. standard 5m 50mm² current leads only, 4Ω load]. Reduced output: Down to 100V 50/60Hz [refer to data sheet for detail]. Test Current Range: 10A to 600A unsmoothed DC in 1A steps. Accuracy: ±2% ±2A. Test Modes: Manual, Auto, Continuous. Test Time: 7 seconds normal /auto mode. Refreshed every 2 seconds in continuous mode. Volt-meter input impedance: >200kW. Data Transfer: Real time or batch download via RS232 using AVO Download Manager. Storage Capacity: 300 result sets.

Megger DLRO Wind Turbine Lightning Protection Test Lead Set

MEG,DLRO-100LEAD (1263) AUFor Megger DLRO 10 series digital microohm meters. Specially designed for measuring resistance of lightning protection circuit between wind turbine blade tip and ground. Kelvin clip and hook ends on 100m cable reel. 5m DH2 lead with duplex hand spikes and hook end.

Megger DLRO lead set Current & Voltage LeadsMEG,DLRO-LEADSET (1263) AUFor Megger DLRO digital micro-ohm meters potential spike lead set x2 and current clip lead set x2. Leads are used to separate the C & P connections. This avoids the erroneously high readings taken due to a high resistance contact. Current clip lead set 2m (242041-7) and Potential Spike set 2m (242021-7).

Megger LT330 Non-tripping Loop Tester, 3Ph Safe, 1ph or ph-phMEG,LT330 EN-AU (8445) AU

Non-tripping loop tester. 3 phase safe, single or phase-phase loop testing. 2 wire test (high current). Single phase loop testing. Phase - Phase loop testing. L-N-E polarity indicators. PFC display. Phase rotation indicator. Frequency measurement. Max Z display. R1 + R2 display. Voltage measurement. Data storage & download via USB. IP54 weatherproof. IEC61010-1 300v CAT III. EN61557.

T&R DSM200 200A Micro-Ohm MeterT&R,DSM200 (1264) AUMaximum output current 200A. Maximum resolution 0.1μΩ. Digital display with RS232 output. AC mains operation. Complete with 3m leads.

Power Analysers & Recorders See also Current Clamps Probes & Accessories on page 36-38

CCI Power-Mate 15A Single Phase Power/Energy MeasurementsCCI,POWER-MATE 15A (8803) AU

Can accurately measure and calculate power, volts, amps and energy being used by an electrical appliance. Also measures the greenhouse gas emission created by an appliance. Can determine the actual running cost, how much energy the appliance used in kilowatt-hours and how many kilograms of greenhouse gas emissions it produced all in hourly, yearly,

quarterly and accumulated figures. Features an LED display for easy reading and high visibility at all times. 15 amp version - to a maximum continuous capacity of 15A, but readings are accurate to 18A and the cable is rated to 15A. Provides a variety of measurements including: power in watts, voltage and current. Provides the minimum, maximum as well as instantaneous readings.

CHK PM20 Power Quality Analyser/LoggerCHK,PM20 MY

Three phase, weatherproof IP65 field unit. Three voltage channels 63 to 440V (isolated). Four current channels 0 to 3kA RMS (3ph & neutral). Supplied with 3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and 500A for neutrals clamp-on CTs are available. Memory 4Mb. In-built 2 line LCD

display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and tariffs, high speed RMS waveform capture events outside preset limits (10ms inter-vals). Software provides graphs and summaries to PC. Download files while logging. RS232 interface. PC using Win 95, 98 or NT4 O/S, is required with the CHK POWERview software to configure this unit before operating.

CHK Gridsense PM30 3 Phase Powermonic Power LoggerCHK,PM30 (8788) AU/MY

Weatherproof IP65 field unit. Channels 3 voltage, 63 to 440V (isolated), 4 current 0 to 3kA (3ph & neutral) RMS. Supplied with 3 x 1kA clamp-on CTs (cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors and 500A & 100A for neutral conductor current measurement are available. Memory 4Mb.

In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 48th). Total energy, tariffs, max demands, transient and sub-cycle disturbances. Software provides graphs and summaries to PC. Download files while logging via RS232 interface. PC using Win 95, 98, NT4, 2000, XP, O/S, is required with the CHK POWERview software to configure this unit before operating.

CHK Gridsense PM30 Plus 3 Phase Powermonic LoggerCHK,PM30PLUS (8778) AU/MY

Weatherproof IP65 field unit. Channels: 3 Voltage, 63 to 440V (isolated). 3 current 30 to 3,000A (3ph) rms. Supplied with 3 flexible 3,000A clamp-on CTs (flexible CT length 600mm and 190mmØ). (In addition, clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A for neutral conductor current measurement are available.) Memory: 4Mb. Inbuilt two line LCD display. Records: V, A, pf, f(Hz), kVA,

kVAr, kW, harmonics, (THD and individual to 48th). Total energy, tariffs, maximum demands, transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Download files while logging RS-232 interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required with the CHK POWERview software to configure this unit before operating.

ELECTRICAL POWER www.techrentals.com.au

Save your time and reduce your real costs. Find out all about our Confi guration and Download solutions on page 11.

Page 5: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

33

“The best service, at the best price, in the best time!”

TR VMS Booking Service To minimise downtime, TR VMS provide a Booking Service to assist you in effectively and effi ciently managing your equipment utilisation. Just call your nearest TR VMS offi ce and arrange a date for the next available time slot.

A quote will be provided stating that the equipment is to arrive at the TR VMS offi ce the day before the work is due to be done. Simply sign the acceptance of the quote and return.

HyperCal Calibration Service - When your need is urgent You also have the choice of a Hypercal Calibration Service, for when the calibration is urgent, and your job will be “next on the bench” and in most cases with a one day turnaround. There is a surcharge for this service.

Otherwise utilise the standard calibration service which may take 10 business days for calibration.

Ask about out Mobile Calibration Laboratory.

A U S T R A L I A ’ S L E A D I N G C A L I B R A T I O N L A B O R A T O R Y . E S T A B L I S H E D 1 9 8 9 .

Call now for all your calibration requirements.

1300 790 480Locations in Brisbane and SydneyAuthorised Service Agents for Tektronix and Barfi eld productswww.trvms.com.au

VM0

07

2

Booking Calibration Service – Minimise downtime and optimise utilisation of your equipment

Distributors of Honeywell Aerospace Zing Products. Used in vibration monitoring of both helicopters and fi xed wing aircraft.

Page 6: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

34

Power Analysers & Recorders cont’d. CHK PM35 Power Quality Analyser/LoggerCHK,PM35 (8788) MY

Power logger and disturbance analyser. Weatherproof IP65 field unit. 3 Voltage (55 to 520VAC) and 4 current (0 to 3,000A) channels. Supplied with 4 flexible 3,000A clamp-on CTs (flexible CT length 600mm and 190mmØ). Memory: 15Mb. Inbuilt two line LCD display. Records: V, A, pf, f(Hz), kVA, kVAr, kW,

harmonics, (THD and individual to 48th ). Flicker (Pst & Plt), Total energy, tariffs, maximum demands, transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Download files while logging. High speed USB interface. A PC using Windows 95, 98, NT4, WIN2000 or XP (Vista in compatability mode)O/S, is required with the software to configure this unit before operating.

CHK Gridsense PM40 Power Quality AnalyserCHK,PM40PQA (8779) AU

Weatherproof IP65 field unit. Channels: 3 Voltage, 63 to 440V (isolated). 4 current 0 to 3,000A (3ph and neutral) RMS. Supplied with 4 flexible 3,000A clamp-on CTs (flexible CT length 600mm and Diameter 190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current imbalance (THD and individual to 48th ) and Flicker. Total energy, tariffs, maximum

demands, and transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Download files while logging USB interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required with the CHK PowerView software to configure this unit before operating.

CHK PM45 Power Quality AnalyserCHK,PM45 (8779) AUSuitable for low voltage investigations,

power profiling and load studies, harmonic analysis,power factor studies & flicker and imbalance monitoring. Features IEC61010 Cat IV 600V safety certificate, weatherproof IP65 case, 4 channel voltage and 4 channels current. Supplied with 4 x Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd 0 to 60VAC, Current input 0 to 3,000A.

Dranetz-BMI Power Guide 4400DRA-BMI,PG4400 (8700) AUProvides the full range of

measurements include V, I, W, VA, VAR, TPF, DPF, demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum (V, I, W) to the 63rd, fl icker (Pst, Plt), crest factor, K factor, transformer de-rating etc.

Asset comes with AC fl exible current clamp DRA-BMI,RR3035A/24, current range 30/300/3,000A AC only. Can be extended to different ranges of measurement AC/DC by selecting appropriate current clamps. Has the full range of arithmetic, vector and sequence parameters to evaluate distorted and un-balanced loads as defi ned in IEEE 1459. Exceeding high/low limits of any active parameter can trigger logging. Voltage & current disturbances. DRA-BMI,PG4400 analysers can be used for power quality measurements, current inrush fault recording long term monitoring and continuous logging at 1s inter-vals. DRA-BMI,PG4400 is Class A compliant with IEC Standard 61000-4-30, AS61000-4-7 and AS61000-4-15.

Power Analysers & Recorders cont’d. Dranetz-BMI Power Xplorer PX5DRA-BMI,PX5 (8701) AUProvides the full range of measurements include V, I, W, VA, VAR, TPF, DPF, Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum (V, I, W) to the 63rd,

Flicker (Pst, Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/Avg values are determined in ½ cycle RMS steps. Complete with A/C Flexible Current Clamp DRA-BMI,RR3035A/24, Current Range:- 30/300/3,000A AC only. Can be extended to mentioned different ranges of measurement both AC/DC by selecting appropriate current clamps. High-speed transient capture (1MHz sampling rate) and full range of arithmetic, vector and sequence parameters to evaluate distorted and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits of any active parameter can trigger logging. Voltage and current disturbances can be triggered by peak value, wave-shape change and cycle-by-cycle RMS value change. Pre-event and post-event waveform capture cycles are user adjustable. Voltage and current channels can be cross-triggered. Can be used for power quality measurements, current inrush (cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage logging), long term monitoring and continuous logging at 1s intervals. The four differential voltages and current channels can also be used independently. Class A compliant with IEC Standard 61000-4-30 ‘Power Quality Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.

Fluke VR1710 Single-Phase Voltage Quality RecorderFLU,VR1710 (8734) AU

Single phase power quality analyser. Records RMS, transients, flicker & harmonics up to the 32nd. Selectable logging periods from 1s to 20min. Provides continuous recording with no gaps. Includes software for download, analysis and automatic reporting.

Hioki 2332-20 RPMS SmartSite Remote Power Measurement System HIO,2332-20RPMS (8715) AU

For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3 wire & 3ph 3 wire up to 3 circuits. Provides via a PC, management of measurement data to support energy and environmental management. Modulated measurement units take advantage of a variety of infrastructure to collect measurement data. Use as a stand alone logger and for remote monitoring. Use as a PC measurement logger keeps measuring and continu-ously saves the data. Measurement modules comes with memory and clock. Build a customised and remote measuring system by utilizing existing data network. Modules for temperature, humidity, instrumentation and pulse, power module for multiple circuits. Large internal memory. Communication module with built-in real-time clock tracks - resolution 1s. Air Module for constructing SS wireless systems.

Hioki 3169-21 Clamp-On Power HiTester with 4 x 500 Amps CT’s

HIO,3169-21 CT500AMP (8718) AUMeasurement of single-phase to three-phase 4-wire circuits with a single

unit. In addition to measuring standard parameters such voltage, current, power, power factor, and integrated values, can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. Features: Measure up to 3-phase, 3-wire system (displays voltage and current for three lines), Measure up to four single-phase, 2-wire systems, up to 500A range, compact and light weight, power recording for individual waveforms, simultaneousrecording of demand values and harmonics. RS-232C interface for PC communications, supplied with Hioki 9625 Power Measurement Support Software for data analysis. Includes 4 x Hioki 9667 500A CTs.

ELECTRICAL POWER www.techrentals.com.au

Save your time and reduce your real costs. Find out all about our Confi guration and Download solutions on page 11.

Page 7: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

Power Analysers & Recorders cont’d. Hioki 3169-21 Clamp-On Power HiTester with 4 x 1,000 Amps CT’sHIO,3169-21CT1000AMP (8719) AU

Measure up to 3-phase, 3-wire system (displays voltage and current for three lines), Measure up to four single-phase, 2-wire systems, 5A to 1,000A range. Compact and light weight, PC card data storage, power recording for individual waveforms, simultaneous recording of demand values and harmonics. Complete with RS232C interface for PC communications. Supplied with Hioki 9625 Power Measurement Support Software for data analysis. Includes 4 x Hioki 9669 1,000A CTs.

Hioki 3169-21 Clamp-On Power HiTesterHIO,3169-21CLAMPONPT (8717) AUMeasure up to 3-phase, 3-wire system (displays voltage and

current for three lines), Measure up to four single-phase, 2-wire systems, 5A to 5,000A range. Compact and light weight, PC card data storage, power recording for individual waveforms, simultaneous recording of demand values and harmonics. Complete with RS232C interface for PC communications. Supplied with Hioki 9625 Power Measurement Support Software for data analysis. Includes 4 x Flexible Hioki 9667 CTs (500A, 5,000A switchable).

Hioki 3196 3 Phase Power Quality AnalyserHIO,3196-PQA (8775) AU/MY

High speed (0.5μs 2MHz) field unit. Channels 4 volt-age, 150 to 600V RMS 4 ranges (isolated), 4 current

0 to 5kA (3ph and neutral) RMS 2 ranges. Supplied with 4 x 5kA flexible clamp-on CTs (length 945mm). Memory 13Mb internal, 512Mb compact flash card. Display internal high resolution colour LCD. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 50th order) flicker IEC6100-4-15. Total energy, tariffs, max demands, transient and sub-cycle disturbances. Software provides graphs and summaries to PC. Interfaces RS232 and 10base ethernet.

Power Analysers & Recorders cont’d. Hioki 3196 Power Quality Analyser with Clamp-on CT 1,000 Amps

HIO,3196PQA-CT1000A (8774) AUMeasures power factor, sags, swells, flicker, transients, harmonics to the 50th, high frequency transient, detection and waveform display, 4 current and 4V channels.

Measurement ranges: Voltage ch1 to ch3: 150 to 600VAC RMS-3 ranges, ch4: 60 to 600VAC RMS-4 ranges, or 60/600VDC-2 range. Supplied with 4 x 1,000A clamp on CT’s HIOKI 9669. Measurement method: Transient overvoltage: 2Ms/sec, Harmonic wave: 2048 point (10 cycle @ 50Hz, or 12 cycle @ 60Hz), other effective value: 256 point/one cycle.

Hioki 3197 Power Quality Analyser with 3 x 500A Clamp-on CTs

HIO,3197PQA (8779) AUComprehensive portable PQA. Monitor for: inrush current, voltage swell, voltage dips, transient over-voltage and interruptions. Measure and record: power and power factor,

active/reactive energy, demand, load changes (with graph display), voltage and current. Measures Impulsive voltage quality: transient over voltage (Impulse). RMS voltage quality: voltage swell, voltage dips, voltage interruption. Power quality: frequency, voltage, current, current peak, active/reactive/apparent power, power factor (displaced power factor). Three phase quality: voltage unbalance ratio, current unbalance ratio. Harmonic quality (up to 50th order) : harmonic voltage, harmonic current, harmonic power, harmonic voltage/current phase angle, total harmonic voltage distortion, total harmonic current distortion (THD-F, THD-R).

ELECTRICAL POWERwww.techrentals.com.au

QUALITY PRODUCTSQUALITY RESULTS

Power Analysis

Data Logging

Power Parameters Pty Ltd83 Northern Road, Heidelberg West, Vic 3081

www.parameters.com.au [email protected]: 1800 623 350 Freefax: 1800 067 263

8870-20 Memory HiCorderIR5001 Temperature Humidity Logger

3169-20 Power AnalyserPW3198 Power Quality Analyser

NEW

Cat IV 600V

Class A

Page 8: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

36

Power Analysers & Recorders cont’d. Hioki 3332 Power HiTester Suitable for Standby Power Single PhaseHIO,3332 POWERTESTER (8776) AUSuitable for measuring very low effective power, for stand -by mode of home equipment. Ultra high-sensitive measurement. Use to measure effective power of equipment in standby mode: Current 1mA with 0.1μA resolution. Wide Measurement range, up 5A direct input and auto range facilities are available. Suitable for single-phase/two wire power measurement. Voltage measuring ranges from 15V to 600V six ranges, Power 15mW to 30kW 90 ranges. Integration range 0 to ± 999999MAh/MWh, integration time up to 10,000 hours. RS232C interface. Other features includes measurement of inrush current during device start-up, measurement of standby power under 1W, precise calculations of minute stand by power, when 150V/1mA range is selected, integration from ± 000.000mWh can be performed. Low numbers/units are automatically switched to a 6 digit display, allowing measurement in high resolution.

LEM Topas 1000 Power Network AnalyserLEM,TOPAS1000 (8762) AU

Measures all relevant parameters in one measurement system. Inputs (isolated) voltage 4 channels, 200mV to 1kV, current 4 channels, supplied with 4 x 0 to 10A, 10 to 100A AC

clamp-on CTs and 4 x (unit powered) 0 to 3kA LEM-Flex current sensors. Can be configured for 8 voltage channels. Measuring functions RMS, V(U) voltage imbalance, positive, negative & zero phase sequence, phasor (vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz), energy, on-line oscilloscope, power and multimeter, harmonics (by power/direction, magnitude & phase), inter-harmonics, THD, flicker, transients (100kHz to 10MHz), will capture events from 0.1μs in duration. Software configured manual or auto trigger levels, ethernet or serial interface, memory >540Mb/HDD.

Megger MMC850 Multi/Single Core AC Clampmeter - 200 AmpsMEG,MMC850CLAMPMETER (8776) AUMulti/Single Core AC. Clampmeter single, two or three core cable measurement. Flat or round section cables; no need to split wires. Measures up to 200A on single-core, 100A on multi-core cables. Cable centralising clamp, backlit display, 50Hz and 60Hz supplies, IEC 1010-2-032, CAT III 600V safety protection.

Megger SK-MDP3 Distribution Profiler 1000Amps/35kVMEG,SK-MDP3 (8727) AU

Records currents up to 1,000A, plus 200A over-range. Waveform capture and harmonic analysis up to the 32nd order. Power factor/power and relative voltage RMS magnitude, overhead line spring attachment, accurate data capture via advanced MDP software, Lightweight battery operated, weather resistant. Easy plug-in for quick data retrieval.

Metrix MX2040 AC/DC Clamp-on MeterMET,MX2040 (8811) AUMeasures A, V, Hz, kW, kVA, kVAR, kWH, PF and resistance. Ranges 200A & 2kA, 600V & 1kV, 20, 200kW & 2MW & kWH. Scale length 3,000. 1 & 3ph operation. Motor rotation indication. Peak, min, max, average, RMS, and crest factor indication. Peak response time 1μs. Analogue output option fitted giving dynamic signals and calculated parameters (energy, etc). Jaw opening 55mm for 22 x 64 bars.

Power Analysers & Recorders cont’d. Metrosonics PF-1-F Overhead ProfilerMET,PF-1-F (8726) AUDistribution line profilers for current measurement on power lines. Logs current consumption to internal memory. Set of 3 profilers with one display module. Windows software included. Current range 5 to 1,000A. Resolution 1A. Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate 1s to 10min. Memory 64k readings. Data storage modes: stop when full or wrap around. Data retention after low battery shutdown 30d. Min conductor spacing 600mm.

AC Electrical Chart RecordersHioki 9132 Clip-on AC Current TransducerHIO,9132 (8604) AURanges 20 to 1kA fs. Short term overload capability 2kA. Output 0.2VAC. For use with Hioki 8800 series recorders, for current waveform recording.

Current Clamp Probes & Accessories See also Electrical Testers on page 29 & 30 See also Power Analysers & Recorders on page 32-36

CHK 3 Phase Converter for CTs 1A Input to 200mA OutputCHK,CK1 (8791) AUAdaptor for CTs with 1A secondary outputs, this unit suits CHK,PM30/20.

CHK 3 Phase Converter for CTs 5A Input to 200mA OutputCHK,CK5 (8785) AUAdaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.

CHK CR100 Clamp-on CTCHK,CR100 (8782) AU/MYJaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to measure neutral current. Accuracy Class 1.

CHK CR500 Clamp-on 500 CTCHK,CR500 (8789) AUJaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to measure neutral current. Accuracy Class 1.

CHK CT1000L Large 1kA Primary Clamp-on CTCHK,CT1000L (8796) AULarge 123 x 35mm 1kA primary clamp-on CT for CHK,PM20/30.

CHK CT3000L Large 3kA Primary Clamp-on CTCHK,CT3000L (8790) AULarge 123 x 35mm 3kA primary clamp-on CT for CHK,PM20/30.

Dranetz Communications Adapter - Fibre to Ethernet with Node Link SoftwareDRA-BMI,CAF-ETHERNET (8709) AUCommunications Adapter-Fibre to Ethernet with NodeLink Software and Moxa Networking Software for the following Dranetz-BMI Models: DRA-BMI,PX5, DRA-BMI, PX5-400, DRA-BMI,PG4400.

ELECTRICAL POWER www.techrentals.com.au

Page 9: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

37

Current Clamp Probes & Accessories cont’d.Dranetz View Math Driver Software (Add On)DRA-BMI,DVMDS (8703) AUIn 4 essential areas, the Math Package will improve measurements:- Rescue Kit. Ever hooked up a probe the wrong way? May be forgotten to check if the actual time in your instrument is running correctly? Or could you have possibly forgotten to set the correct K-factors? The Math Package helps you to correct these errors, re-calculate parameters from available wave-form data, invert waveforms and much more. Improve Measurements / Reports. Calculate additional parameters for your Multi-DAQ TASK Card, fault-recorder/inrush mode measurements, with the math driver the following additional trends will be created for Multi-DAQ data files: V RMS, Watts, VAR’s, VA, True PF, V thd (%fundamental), I thd (abs current) Voltage Frequency (for internal trigg) and Net Totals V RMS, Amps, W, VAR & VA. Generate More parameters from waveform data. Showing Displacement Power Factor (DPF) instead of K-factor. Rename inputs. Energy ON/OFF peak calculations. Advanced mathematical expressions and formulas can be used to plot additional user-defined channels within both the time-plot chart and the waveform chart. Advanced analysis, watt harmonics, symmetrical components, etc.

Dranetz AC/DC Current Clamp 3 to 1500A RMSDRA-BMI,PR1500 (8708) AUMax conductor size is 52mmØ. Current clamp is suitable for any of Dranetz-BMI models DRA-BMI,PG4400, DRA-BMI,PX5. Current clamp/probe is very useful for current measurement through CT current transformer. CT Ratio can be selected on the Dranetz-BMI above-mentioned models.

Dranetz PR6035A/36 Flexible Current Clamp 60/600/6,000ADRA-BMI,PR6035A/36 (8704) AUSet of 3 flexible current clamps 60/600/6,000A RMS, max conductor size/length of clamp is 36”. Current clamps are suitable for any of Dranetz-

BMI Models. DRA-BMI,PG4400/DRA-BMI,PX5. Current clamp/probe is very useful for current measurement through CT current transformer. CT Ratio can be selected on the Dranetz-BMI above-mentioned models.

Dranetz TR2021 Current Clamp 1 to 30A 48Hz to 10kHzDRA-BMI,TR2021 (8706) AUSet of 3 current clamps 1 to 30A RMS, 48Hz to 10kHz. Max conductor size 12mmØ. Current clamps are suitable for DRA-BMI,PG4400, DRA-BMI,PX5 and DRA-BMI,PX5-400 models and are very useful for current management through CT current transformer. CT Ratio can be selected on the above-mentioned models.

Current Clamp Probe 0 to 1A RMSDRA-BMI,TR2501 ( 8705) AUSet of 4 current clamp/probes, range 0.05 to 1.2A RMS. Max conductor size 12mm dia. Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5 and DRA-BMI,PX5-400. For current measurement through CT current Transformer. CT Ratio can be selected on the above mentioned models.

Dranetz TR2510 Current Clamp Probe 0 to 10A RMSDRA-BMI,TR2510 (8705) AUSet of 3 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mm dia. Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5 and DRA-BMI,PX5-400. For current measurement through CT current Transformer. CT Ratio can be selected on the above mentioned models.

Current Clamp Probes & Accessories cont’d.

Fluke True RMS Clamp Meter 1000A AC/DC with Flex Probe

FLU,376 (8733) AUIncludes a flexible current probe. will record Min Max and Average. Measures AC Volts(1000V), DC Volts (1000V), Resistance, Capacitance (1uF to 1000uF) & Continuity.

Fluke i1010 AC/DC Current Clamp 1,000A DC and 600A ACFLU,I1010AC/DC CLAMP (8737) AUBattery-powered Hall-effect probe measures 1A to 1,000A. 1mV/Amp output guarantees easy reading on your meter. Take accurate current readings without breaking the circuit.

Fluke i410 AC/DC Current Clamp 400A AC/DCFLU,I410 AC/DC CLAMP (8738) AUBattery-powered Hall-effect probe measures 1A to 400A. 1mV/Amp output guarantees easy reading on your meter. Take accurate current readings without breaking the circuit. Maximum conductor Ø 32mm. CAT III 600V safety rating.

Hioki AC/DC Clamp on Meter with Analog Output 20/200AHIO,3284 (8756) AUCan also measure volts, ranges 30V, 300V, 600V AC/DC. Frequency ranges 10Hz, 100Hz, 1,000Hz. Display LCD, counts max 2,500 current, 3,750 voltage, 1,250 frequency. Output voltage 1V for 2,000 count on full scale for each current range, can select Rec rms output, response time about 250ms rise time, fall about 500ms. Select Mon for waveform output. 1V is produced for 1,000 count on full scale frequency range. Output not available for voltage measurements. Supplied with signal output cord, 4mm to BNC convertor, carry case and AC adaptor. Note: Can be powered with internal 9V battery or AC adaptor. (AC adaptor not supplied.)

Hioki 3285 AC/DC Clamp-on Meter with Analog OutputHIO,3285 (8755) AURanges 200A/2kA AC/DC. Measure volts, ranges 30V, 300V & 600V AC/DC. Frequency ranges 10Hz, 100Hz & 1kHz. Display LCD, counts max 2,500 current, 3,750 voltage and 1,250 frequency. Output voltage 1V for 2,000 count fs for each current range, can select Rec RMS output, response time about 250ms rise time, fall about 500ms. Waveform output. 1V is produced for 1,000 count on full scale frequency range. Output not available for voltage measurements. Supplied with signal output cord, 4mm to BNC convertor, carry case and AC adaptor. Powered with internal 9V battery or AC adaptor. (AC adaptor not supplied) adaptor.

Hioki 3290 Clamp-On AC/DC HiTesterHIO,3290 MYCurrent Measurement at DC and from 1Hz AC to 1,000Hz. Current Clamp Hioki 9693 Clamp-on AC/DC sensor ranges: 20, 200 & 2,000A, jaw opening 55mm.

Hioki 9660 Clamp-on 100A AC CTHIO,9660CT100A (8740) AURated primary current 100A AC. Amplitude accuracy: ±0.5% rdg. ±0.2%fs (at 45 to 66Hz). 66Hz-5kHz ±1% or less. Max circuit voltage 300V RMS/insulated wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.

ELECTRICAL POWERwww.techrentals.com.au

Page 10: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

38

Current Clamp Probes & Accessories cont’d.

Hioki 9661 CCT-500A Clamp-On Sensors 500A, 500mVAC OutputHIO,9661 CCT-500A (8742) AU500A rated, 500mVAC f.s. output, core jaw dia 46mmØ. Designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all CE

marking requirements. Basic specifications: Rated input current 500A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz), amplitude: ±0.5% rdg ±0.2% f.s. Full scale (f.s.) is the 3196 range value, phase: ±0.5° or less, frequency characteristics 66Hz to 5kHz (±1% or less from accuracy), max allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire), core jaw Ø46mm, dimensions, mass 77mm W x 151mm H x 42mm D, 360g, cord length 3m.

Hioki 9661-01 CCT-500A Clamp-on Sensors HIO,9661-01 CCT-500A (8742) AU500A rated, 500mVAC fs output, jaw 46mmØ. Rated input current 500A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz). Amplitude ±0.5%rdg, ±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency

characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire). Dimensions 77mm W x 151mm H x 42mm D, cord 3m. Suitable for Hioki models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVAC input.

Hioki Flexible Clamp-on Sensors 10Hz to 20kHz, 500/5,000AHIO,9667-FCT-5000A (8792) AU10Hz to 20kHz, 500/5,000A rated, 500mV AC f.s. output, 254mm diameter maximum. Designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all CE marking requirements. Basic specifications: Rated input current 500A AC, 5,000A AC, rated output current 0.5V AC, accuracy (at 45 to 66Hz). Amplitude: ±2% rdg ±1.2mV, full scale (f.s.) is the 3196 range value, phase: ±1° or less, frequency characteristics 10Hz to 20kHz, maximum allowable input continuous 1,0000A rms (45 to 66Hz), maximum circuit voltage 1,000V AC rms (insulated wire), core jaw dia Ø254mm(10in). Dimensions: mass 254mmW x 86mmH x 30mmD, 140g. Sensor length: 910 mm. Suitable for the following Hioki Models: HIO,3196PQA, HIO,3197PQA, HIO,3169-20CLAMPONPT, HIO,2331-20RPMS, HIO,2331-20RPMS, HIO,8715-01, any data logger/scope which takes up to 1.7mV AC input.

Hioki 9669-CCT-1000A Clamp-on SensorsHIO,9669-CCT-1000A (8744) AUJaw 55mmØ, 80mm x 20mm busbar. Rated input current 1,000A AC, rated out-put current 0.5VAC, accuracy (at 45 to 66Hz) amplitude ±1% rdg, ±0.01% fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics 66Hz to 5kHz

(±1%), max. Allowable input continuous 1,000A RMS (45 to 66Hz), max cir-cuit voltage 600VAC RMS (insulated wire). Dimensions 99.5mm W x 188mm H x 42mm D, cord 3m. Suitable for Hioki models 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVAC input.

Current Clamp Probes & Accessories cont’d.

Hioki 9670 Thermal Printer, Input RS232C, suitable for most of the Hioki SeriesHIO,9670 PRINTER (8759) AUOperates from a computer or the other host system. Battery operated. Prints 16 x 16 dots and 24 x 24 dots (as well as Japanese characters JIS Level I and II), and can print bar codes. Provides various settings such as enlarged-character printing. Graphics can be printed using bit images. Suitable for most of the Hioki Series.

Hioki 9694 Clamp-on CT 5AHIO,9694CT5A (8741) AURated primary current 5A AC. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at 45 to 66Hz), 66Hz to 5kHz ±1% or less. Max circuit voltage 300V RMS/insulated wire. Core jaw 15mmØ. Size mm: 46w × 21d × 135h, cord length 3m.

LEM Current Probe 10A to 1A Suitable for LEM,TOPAS 1000 PQALEM,CURRENT PROBE10A (8763) AU10A to 1A suitable for LEM Topas 1000 power quality analyser.

LEM FLEXII 30, 300 & 3,000A TransducerLEM,LEM-FLEXII (8638) AUFlexible wrap-around AC current transducer. Length 600mm. Ranges 30, 300A & 3kA. Frequency response 1 to 20kHz. Accuracy 1%. Phase error 0.5°. Output 3V RMS @ full scale. Requires 3 units for 3ph. Designed for multimeters and oscilloscopes (4mm banana plug or BNC connectors). Other instruments may be attached providing the correct adaptor/transducer and connection is available. Operates for 100h from 2 x 9V batteries.

Universal Technic P75.3C DC/AC Amp ClampUNI,P75-3C (8712) AUMax current 7,500A DC & AC peak. Bandwidth 1kHz. Min range 1kA. Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size 122 x 54mm or 100 x 64mm. Max cable size 83mm. Battery 9V, life 100h. Output sockets 4mm. DC current gives DC output, AC current gives AC output, 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.

Universal Technic Clamp-On AC/DC Current Probe 4000/7500AUNI,P75-3C HYBRID-DP (8713) AURanges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and external power supply, 3V operation. Safety sockets 4mm. Clamp is suitable for use with any instrument with an input range of 2VAC or DC, and an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders, oscilloscopes, and power quality analysers.

Insulation Testers & Meggers to 20kVFluke 1587 Insulation Multimeter FLU,1587 MYInsutation: measurement range: 0.01M to 2GΩ. Test Voltages: 500V, 1,000V, 50V, 100V, 250V, 500V, 1,000V Multimeter: Voltage 1mV to 1,000VAC/DC, current 0.01mA to 400mA AC/DC, resistance 0.1Ω to 50.0MΩ, capacitance 1nF to 9999microF, frequency 0.01Hz to 99.99kHz.

Fluke 1653 Electrical Installation Tester FLU,1653 MYTester verify the safety of electrical installations, according to IEC 60364, HD 384 standards. Functions available: voltage and frequency measurement, insulation resistance testing, continuity testing, loop impedance, RCD tripping time, RCD tripping current, Earth resistance and Phase sequence.

ELECTRICAL POWER www.techrentals.com.au

Page 11: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

39

Insulation Testers & Meggers to 20kV cont’d.Hioki 3454 Digital MΩ HiTester Insulation TesterHIO,3454-51-3 (8404) AUContinuity function with 200mA and 3 range voltage selectable 250V, 500V & 1kV. Digital display, auto-discharge, live-wire warning, safety system for high voltage measurement, sliding cover. Backlit LCD. Checks ground wire continuity with a short circuit current of 200mA. Ground continuity testing in accordance with IEC 60364. Insulation resistance maximum 4,000MΩ @ 1kV. Other functions:- insulation and low resistance mode - comparator, measurement value hold, insulation resistance mode - auto discharge, insulation and AC voltage mode. Maximum rated working voltage 600VAC.

Hioki 3455 High Voltage Insulation TesterHIO,3455HVIT-5kV (8403) AU/MY

PI and DAR function to check insulation quality and step voltage test to detect for signs of deterioration. Generates test voltages from 250V to 5kV in commonly used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or decrements of 25V

or 100V. Insulation diagnoses for automatic calculation and indication of PI (Polarisation index) and DAR (Dielectric absorption ratio), step voltage testing and temperature correction. Large memory stores up to 100 manual records and a logging function for 10 data (360 times). Stored data with date and time may be displayed on the LCD or down-loaded.

Megger 10-01 10kV Insulation TesterMEG,10-01-10kV (8424) AUCompact, Microprocessor controlled

high voltage DC Insulation tester. Test voltage: 500V to 10kV.

Megger BM21 500V/1/2/5kV Insulation Test SetMEG,BM21 MYTest voltages 25 to 5,000V in 25V steps. Insulation range to 1TΩ at 500V, 5TΩ at 5kV. AC/DC voltage measurement 50V to 1kV. Leakage current measurement. Capacitance measurement at end of test. Automatic discharge of capacitance. In-built test timer. Insulation burn mode - short circuit current 1mA nominal. Battery life 8h, in-built charger for charging from mains or 12VDC.

Megger FT6/12 Ionisation, Leakage & Breakdown TesterMEG,FT6/12 (8433) AUAC ranges 0 to 2kV, 0 to 6kV, DC ranges 0 to 4kV, 0 to 12kV. Output currents 7.4mA, 8.9mA AC & 2.1mA, 2.5mA DC. Breakdown and flashover indication by latching indicator for periods exceeding 1ms. Current threshold 100μA to 1mA. Ionisation indication by internal speaker. Meter indication of AC, DC and AC capacitive currents. Complete with probes.

Megger MIT1020 Diagnostic 10kV Insulation Resistance TesterMEG,MIT1020-10kV DIT (8425) AU

Backlit display, variable test voltage from 50 to 10,000V, Automatic IR, PI, DAR, SV and DD tests, measures to 35TΩ, RS232 & USB download of results. IEEE 43-2000 recommends the use of 10kV for motor windings rated above 12kV. Protection rating of IP54. Mains or battery powered.

Megger S1-1052 High Current Insulation Resistance Tester 10kVMEG,S1-1052 10kV-DIT (8413) AU

High output current 5mA for fast charging of capacitive loads. Testing up to 10kV, mains or battery powered, digital/analogue backlit display, variable test voltage from 50 to 10,000V, automatic IR, PI, DAR, SV and DD tests. Measures to 35TΩ. RS232 and USB download of results.

Insulation Testers & Meggers to 20kV cont’d.

Megger S1-552 High Current Insulation Resistance Tester 5kVMEG,S1-552 5kVDIT (8415) AU

High output current 5mA for fast charging of capacitive loads. Testing up to 5kV, mains or battery powered, digital/analogue backlit display, variable test voltage

from 50 to 5,000V, automatic IR, PI, DAR, SV and DD tests. Measures to 15TΩ. RS232 and USB download of results.

Oil, Hipot & VFL Testers above 20kV See also Cable & Pipe Tracers & Fault Locators on page 29

Baur DAP75 Insulating Oil TesterBAU,DPA75 (4626) AUFully automatic insulation oil tester. Output voltage 0 to 75kV RMS. Selectable programmes to international standards. Integral printer. RS232 interface. One transit case on wheels. Total weight is 35kgs.

High Voltage Inc PFT303 Test Set 30kV/50Hz AC Hi Pot TesterHIV,PFT303 (8401) AURated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA ½h on 2h off, at 2kVA 1h on 1h off. Tests the integrity of items including insulating materials, isophase bus duct,

switchgear, transformers, vacuum bottles & interrupters, vacuum switches, automatic circuit reclosers, bushings, fuses, arrestors, circuit breakers, transformers, capacitors, motor and generator windings.

High Voltage Inc PFT503, 50kV AC Test SetHIV,PFT503 (8400) AURated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA ½h on 2h off, at 2kVA 1h on 1h off.

High Voltage Inc Very Low Frequency (VLF) 6022 60kV Hi-pot Test SetHIV,VLF6022 (8461) AUFor field testing of AC high/medium voltage cables, bushings, and insulators. Input 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0 to 60kV AC peak,

frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance 1.1μF (approx 3kms of cable at 0.1Hz), 2.2μF (approx 9kms of cable at 0.05Hz) & 5.5μF (approx 13kms of cable at 0.02Hz). Display 0 to 60 peak kV. Interconnect cable length 3m, control unit to HV transformer. RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control units shipped in travel cases weighing 70 & 40kg respectively.

High Voltage Inc VLF-90CM 90kV Test SetHIV,VLF90 (8462) AUVery low frequency (VLF-90CM) AC hipot test set with 90kVAC peak output, is suitable for testing cables up to 50kV. High load capacity enables it to test up to approx 7 miles of cable, depending on type. Includes a charging current and load capacitance meter, test dwell timer, and polarity

indicating lights. Output voltage and frequency, sinusoidal 0 to 90kVAC peak & selectable, 0.1, 0.05, 0.02Hz. Test frequency and rated loads with approximate cable lengths are: -0.1Hz/0.55μF 1,673m of cable, 0.05Hz/1.1μF 3,353m of cable, 0.02Hz/2.2μF 6,706m of cable. Kilovoltmeter scaled 0 to 100kVAC peak, ammeter scaled 0 to 100mA AC and 0-6μF load capacitance. Weight of the unit 167kgs. HV Cable output is 6m flexible, shielded x-ray with alligator clamp, inter connect cable length 3m, shorting stick 6m lead with clip.

ELECTRICAL POWERwww.techrentals.com.au

Page 12: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

40

Oil, Hipot & VFL Testers above 20kV cont’d.

HV Diagnostics HVA TD60 Portable TanDelta Measurement SystemHVD,HVA TD60 (4620) AUTan Delta or Power Factor tester used to determine the power factor of cables, transformers, capacitors, rotating machines and other switchgear. This test allows the detection of insulation defects before they fail inservice. Used in conjunction with the HVD,HVA60 VLF tester.

HV Diagnostics HVA30 30kV-15mA DC/VLF High Voltage Insulation DielectricsTest Set

HVD,HVA30-DC/VLF (4622) AUVLF (0.1Hz), DC (±), cable fault conditioning(burning), and sheath/jacket testing modes all included. 0.1Hz & 0.02Hz. For solid dielectriccables such as XLPE and EPR. Fully automaticor manual cable test sequences comply-

ing with International Standards/Guides such as IEEE 400.2, VDE 0296, CENELEC, etc. True symmetrical sinusoidal, load independ-ent, output waveform across the full load range. Real-time display of actual output waveform. Easy to use, menu guided. Large output load capability (up to 5μF). Automatic and integrated load capacitance measurement with optimum frequency selection. Data storage for review or download. Short circuited protected.

HV Diagnostics HVA60 60kV-50mA DC/VLF High Voltage Insulation Dielectrics Test Set

HVD,HVA60-DC/VLF (4624) AUTrue sine wave low frequency output. 0.1Hz & 0.02Hz. For VLF, DC and jacket/sheath testing. Fault conditioning capability. Test result storage capability. Short circuit protection. Complies with CENELEC,

IEEE 400.2, VDE 0296 and other international standards. Manual or fully automatic test sequence selection. Real time display of actual output waveform. High voltage power source suitable for testing electrical plant including cables: XLPE, PE, EPR, PILC etc, capacitors, switchgear, transformers, rotating machines, insulators and bushings.

Megger OTS80PB Transformer Oil Tester Insulation Dielectrics Test Set

MEG,OTS80PB (4628) AUTest voltage 80kV max at 61.8Hz. Fully automatic operation. Rechargeable batteries. RS232C interface.

Phenix BK130 130kVAC Hipot Aerial Lift Test SetPHE,BK130 (8406) AUTests elevating boom as well as the work platform and linings to ANSI A92.2 draft standard. Can also he used in many other Hipot applications that require the sort of voltage and current this instrument is capable of. Can supply 0 to 130kVAC @ 50mA and 0 to 35kVAC at 171mA. The whole system is built into a trolley cart for ease of use. Measurement accuracy 1% FS for 10 to 100% of range.

T&R kV30-40, 30kV AC Hipot Test SetT&R,kV30-40 (8402) AU0 to 30kV, max output 40mA with a duty cycle of 5min on & 15min off. Max continuous current 20mA. Overload trip may be set from 4 to 44mA. Zero interlock and key operated safety features.

Power Transformer TestersBiddle 550005 Turns Ratio Test SetBID,550005 (8421) AUSingle phase (can be used on 3ph individual phase windings). Turns ratio 0.001 to 129.999. Exciting current 0 to 1A. Accuracy 0.1%. Hand cranked operation.

Megger 3Ph Transformer TesterMEG,TTR320-47 (8422) AU3 phase transformer turns ratio test set. Automatic operation, graphical user interface. Stores upto 100,000 data sets.

Omicron CPC 100 PTS for CTs/VTs/Power TransformerOMI,CPC100PTS (4606) AUAllows multifunctional primary test system for substation commissioning and maintenance. Automated testing of power transformers, CTs, VTs, resistance testing, and more. Providing up to 800A (or 2,000A with current booster) and 2,000V and comes complete with an

integrated PC. Its software routines test a wide range of substation equipment, and automatically creates customizable reports. Total weight: 112kg including all the accessories. Analog voltages and currents can be measured with very high precision. Its Ohm meters automatically switch ranges from μOhm to kOhm to allow for a wide variety of applications. Testing of unconventional equipment, such as Rogowski Coils or current sensors completes the spectrum. Safety features: emergency shut off button, safety key lock (block unauthorised use).

Omicron CPSB1 Switch BoxOMI,CPSB1 (4605) AU

Switch Box to allow fully automated 3 phase transformer testing, accessory for the CPC100.

Omicron CP TD1 Tangent Delta & Power Factor Measuring Test SetOMI,CP-TD1 (4619) AU

Provides automatic testing of transformer parameters within one portable system. Comprises of CPC 100 Multifunction Primary Test System and the CP TD1 Tangent Delta unit. CPC 100 is the main control unit for the test system and the CP TD1 unit is used for testing of insulation condition. All test results stored in one

device and in the same format. Excellent line-frequency suppression in the presence of electrical and magnetic interference. High precision components for measuring voltages and currents and a gas-insulated reference capacitor for capacitance and Tan delta measurement. Portable, heaviest component 29kg. Automated Testing and Reporting; Test plans and parameters can be prepared off-line on the computer. Reports are generated automatically.

Omicron FRA Frequency Response AnalyserOMI,FRA (4621) AUFor power transformer diagnosis. Applies a voltage across a range of frequencies (10Hz to 20MHz) to the device under test. The measure-ments can subsequently be used to evaluate the

mechanical integrity of cores, windings and clamping structures within power transformers by measuring their electrical transfer functions over a wide fre-quency range. Each electrical network has got its unique frequency response, the so-called fingerprint. Faults, mechanical shocks (i.e. earthquakes) or transportation cause deviations of this frequency response. Comparing meas-urements of different phases, sister units or the actual fingerprint with earlier measurements done on the same transformers allows to indicate positional or electrical variations of the internal components.

ELECTRICAL POWER www.techrentals.com.au

Page 13: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

41The word “Megger” is a registered trademark

WW

W.M

EG

GER

.CO

M

Rugged, small and lightweight Up to 60 Amps per phase Up to 6 currents with convertible channels Thermally controlled fans for quiet operation New Smart Touch View Interface (STVI) provides manual control New STVI Overcurrent Test includes over 100 relay specific

time-curves built-in

With these comprehensive capabilities and extensive testing options the SMRT36 is conceivably the easiest to use 3-phase protective relay test system available today.

For more information on the SMRT36 Relay Test Set contact us today to receive a SMRT36 brochure and Megger Power Catalogue.

Megger Pty LimitedUnit 1, 11-21 Underwood RoadHomebush Australia NSW 2140

T +61 (0)2 9397 5900F +61 (0)2 9397 5911E [email protected]

SMRT36The SMRT solution for your testing needs.The SMRT36 is the smallest, lightest, highest output powered, complete 3-phase protective relay test system in the world today. This rugged test system may be customized by adding the voltage current generator modules needed for specific test applications. Manual operation is simple through the use of the Smart Touch View Interface (STVI), with a large color high resolution TFT LCD touch-screen.

Page 14: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

42

Current InjectorsMulti-Amp MS-2 High Current Test SetMUL,MS-2 (8415) AUDesigned to test overload relays, circuit breakers and earth fault trip devices. Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A, 24V/25A, 6V/120A & 3V/240A. Short term over

current of several times the rated current ranges is possible. Digital current meter has read and hold facilities for short duration currents. Digital timer measures elapsed time between energisation and the test device operating.

Programma Magnus 2.2kV Step Up Transformer for Testing CT’sPRO,MAGNUS-2.2kV (8464) AUUse in high-voltage substations and industrial environments. Protected with thermal cut-outs, mains voltage 230Vac ±10%, 50 to 60Hz, power consumption is 2.3kVA. Used for preparing excitation curves for instrument

transformers and for demagnetizing current transformer cones. Safety key lock (block unauthorised use).

SMC PTE-100-C Secondary Current Test Set SMC,PTE-100-C (8414) AUAC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A & 10V/100A. Additional outputs AC voltage 0 to 220V at 1A (4A 1min), DC voltage 0 to 350V at 0.7A (2.8A

1min), DC voltage 0 to 250V at 0.25A, fixed 110V AC at 0.3A. Timer 1ms to 99,999s. Additional functions include measurement of the phase angle between the voltage and the current output tap selected, and the measurement of the impedance of the load connected in the current output taps.

T&R 200A-3PH/ED Current injection testerT&R,200A3PHEDIT (8464) AU0 to 200A/phase output capacity. Power supply 4 wire 5A/phase 3ph 240/415V. Typically 10A 5 pin 3 phase socket outlet HPM.

T&R CIT/LU2000 Primary Current Injection Test SetT&R,CIT (8481) AUComprises control unit and 2kA loading unit (LU). Control unit includes timer, current and voltage meters, and variable output transformer. External loading unit output 0 to 2kA, duty 5min on 15min off at 6VAC, continuous 0 to 1kA at 3VAC. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets each 3m long. Control unit connects to LU with supplied interface cable.

T&R PCU1-SP with CT Ratio/Polarity and NLU5000A Loading UnitT&R,PCU1-SP NLU5000A (8482) AU

Medium powered primary current injection system. Features 5kA maximum output current (higher overload current for 2s). Multi-function digital timing system. Digital true RMS memory ammeter. Solid state switching. 2,000A and 5,000A load units. Three range outputs on

loading units. Rugged, compact design. Secondary injection up to 100A. Direct reading CT ratio and polarity. May be configured to either give a maximum current of 5,000A on the 2.3V range, 2,500A on the 4.6V range or 1,250A on the 9.2V range.

Protection Relay Testing SystemsMegger Protective Relay Test System IEC 61850 MEG,MPRT8430-BAS-3CH (4607) AUPerforms routine testing of protective relays. The standard configuration delivers three voltages and three currents, or six currents.

Specifications: AC current output: 0 to 90A, AC voltage output: 0 to 600V, DC voltage output: 0 to 600V, frequency range: 0.001 to 9999.999Hz. The TouchView Interface Controller features a full color, touch screen interface. Includes AVTS software.

Omicron CMA156-6PCA Six-phase Current Amplifier 6x25 AmpsOMI,CMA156-6PCA (4604) AUSix-phase current amplifier for tests requiring higher currents and/or higher power in the current path than is delivered by the CMC 156/256 or more than 3/6 current channels (e.g., for testing three-winding transformer differential protection). Contains six independent current channels. Arranged in two isolated groups (A, B) and can be used independently of those of the CMC 156/256. Connected to the CMC by means of a control cable. With a CMLIB F the available output power can be increased by a factor of 3 (210 VA at 7,5 A instead of 70 VA) for all single-phase fault loops.

Omicron CMC256-6 Advanced Protection Relay Test SetOMI,CMC256-6 (4612) AUAdvanced 3ph dynamic automatic protection relay test system.

Current, integral 3ph current source max 140VA, 6 output sources, resolution 500μA, suitable for most relay types, including some high burden units. Voltage, 3ph 0 to 300RMS. Auxiliary DC supply, 0 to 264V, 0.2A. Relay monitoring trip, monitoring 6 isolated inputs, can be configured to be volt-age free or 0 to 250V. Contact outputs 6 isolated change-over relay contacts (software controlled). Max 250VAC, 10A or 125VDC 1A. Interface connector, 16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated analogue inputs ±500V peak max 12 bit resolution. Input supply 90 to 260VDC, 400Hz. Intuitive on-line help. Laptop and Test-Universe software up to TU V 2.01 sup-plied with test set, interface parallel port.

Omicron CMGPS Syncronisation Control UnitOMI,CMGPS (4616) AUAccessory for the Omicron CMC etc. A single GPS unit, if used to sych relay tests when performing end-to-end tests of line protection systems two are required. The unit provides a start signal pulse based on the GPS clock time base. Software is both integrated in the testing modules (State Sequencer) and can also be used as a stand-alone application.

Omicron C-Probe-1 Clamp-on CT AC/DCOMI,C-PROBE1 (4614) AUAn active AC & DC current probe with voltage output. Recommended accessory for measuring currents with the CMC 256. Two measuring ranges: 10A & 80A. Frequency range DC 10kHz. Accuracy error < 2% for currents up to 40A and frequencies up to 1kHz. Phase error < 0.5O @ 50/60Hz. Length 230mm. Output: 0-10A range 100mV/A, 0-80A range 10mV/A.

Programma EGIL Circuit Breaker AnalyserPRO,EGIL-CB ANALYZER (4600) AUOne main contact per phase. Three time channels are connected together on one side. Events at parallel contacts equipped with pre-insertion resistors are recorded and displayed simultaneously.

Two separate time channels for measurement of auxiliary contacts. On-site hookup comes with ready-made multi-cable sets for both main and auxiliary contacts. Coil currents are measured automatically, presented together with other readings immediately after testing on the display window or via the built-in printer. A built-in sequencer (program unit) sets the instrument automatically for the next sequential breaker operation. Intended primarily for measuring travel (motion). Can be equipped with an optional serial interface (RS232C) for communication with a PC and the CABA Win Breaker Analysis Software.

ELECTRICAL POWER www.techrentals.com.au

Page 15: 4 Electrical Power - Ferretand output signals. AC current range; 10mA to 200A AC, 5 ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC, 1 ranges (±1.5 % rdg. ±5 dgt. at 50

43

Protection Relay Testing Systems cont’d. Programma Sverker 760 Relay Test SetPRO,SVERKER760 (4602) AURelay test set for 1ph protective relay equipment. Three phase relays can be tested 1 phase at a time or by synchronising more than one unit. Current ranges to 100A with full load current to 250A. AC outputs to 250V & DC outputs to 300V. In-built capacitor and resistors for current output phase shifting (3,600). In-built timer, ammeter, and voltmeter. Measures phase angle, PF, and impedance.RS232 communications and control interface.

T&R DVS3-HP Static Relay Test SystemT&R,DVS3-HP (4608) AU

Test system for testing voltage and frequency protection relays and transducers. Tests

Automatic Voltage Regulating (AVR) relays with line drop compensation, under and over voltage relays, directional over-current relays, df/dt (ROCOF) relays, vector surge (step change of phase) relays and check synchronising relay. Generates a 3ph voltage output from a 1ph supply, and may be used in conjunction with a current source to test directional protection. Requires 1ph 50/60Hz supply of 115V or 230V (±15%)..

AC Sources/Inverters/GeneratorsBehlman BL1350C-2 1350 VA Power AmpBEH,BL1350C-2 (8211) AUAC power amplifier with oscillator. Maximum power output 1350VA. Maximum current 10A on 0 to 135V range, 5A on 0 to 270V range. Output frequency 45 to 500Hz. External frequency synchronising input. Remote 0 to 10VDC programming of output frequency and voltage. Digital true rms readout of voltage and current.

Chroma 61501 Programmable AC Power SourceCHR,61501 PAC-PS (8214) AUPower: 500VA. Voltage: 0-150V/0 to 300V/AUTO. Compact size

and weight attributable to advance PWM technology. AC, DC, AC+DC output mode. Programmable output impedance for IEC 61000-3-3. IEC 61000-4-11 voltage dips and variation simulation. Harmonics, inter-harmonics waveform synthesizer for IEC 61000-4-13 testing. Power line disturbance simulation capability. Programmable voltage, current limit. Comprehensive measurement capability, including current harmonics. High output current crest factor, ideal for inrush current testing. Turn on, turn off phase angle control. TTL signal which indicates output transient. Software for IEC regulation test. Analog programmable interface. Optional GPIB and RS232 interface.

Elgar 501 AC Power SourceELG,501 (8209) AUAC power amplifier. Operates from 240V 1ph AC. Output ranges on tapped transformer 0 to 65, 0 to 130, 0 to 260VAC. Output power 500VA. Amplifier output rated over 45Hz to 5kHz. Two units may be connected for 1kVA output. .

Power TransformersFerguson 115-2000 2kVA 240/115V TransformerFER,115-2000 (8203) AU240 to 115VAC, 1kVA stepdown transformer.

Tortech 240-110 2000 VA TransformerTOR,110-2000 AUStep-down transformer. 240 to 110 VAC. 2,000 VA.

Variac 3kVA 0 to 260VAC Output Variable TransformerVAR,3000 MY3kVA 0 to 260VAC output.

Power Transformers cont’d.Variac 6500-3 3ph 6.5kVA TransformerVAR,6500-3 (8208) AUVariac 3ph 6.5kVA. 0 to 470VAC output for 415VAC input, max current 8A/ph.

Dimmer Dot Variable AC Voltage Auto Transformer 3 Phase 23-28AVAR,D-283-OB (8210) AUManual operated air cooled; Input 400/415V, 50Hz. Output 0 to 415/470V. 23 to 28A. Total Weight 95kgs..

Power Line Conditioners/UPSChloride Active 3kVA UPSCHL,ACTIVE3000 (8559) AUDouble conversion sinewave output. Dual PC interfaces. Typical run time 20min. Input (nominal) 2220/230/240VAC 1ph + N. Output 220/230/240VAC 1ph + N ±3%. Efficiency >90%. Dimensions 200mm W x 875mm D x 350mm H. Weight 81kg. MopUPS Professional software for system monitoring and shutdown included. USB port & RS232 communication port for UPS monitoring and management.

Socomec Sicon ENT-TW10 1kVA UPS On-Line Double ConversionSOC,ENT-TW10 (8515) AUSuitable for mainly Business Server, Internet/Intranet Server, Critical Applications, Domestic and Industrial Automation, Networking and ISP/ASP Application etc. On-line double conversion technology, high stability of output voltage and frequency, high input power factor, automatic battery test, optional battery pack expansion, minimal desktop space and easy to install, RS232 and USB communication interface, high efficiency, automatic by-pass, 4 output sockets and slot for insertion of SNMP/WEB Manager or relay card.

Upsonic Power Conditioner 3000VAUPC,3000 (8500) AU3kVA Power Conditioner single phase with 230V/15A power cord and output leads with 230V/15A socket. High energy surge absorbers, LC filter, EMI filter. Fast response time 4ms per step, precise voltage regulation. Flexibility for any loads, like pure resistive load/capacitive load/inductive load. Automatic electronic bypass protection, overload protection, over range protection. Wide input voltage range.

Upsonic Battery Bank - 7AH Suitable for UPS, IH3000 3kVA UPSUPS,BATTERY BANK-7AH (8544) AUBattery Pack 32 x 12V 7Ah suitable for UPS,IH3000 3kVA UPS unit. Fitted with in-built charger card IH 3kVA 500W 120VDC. Back-up run time 2 to 3h at 1,000W load..

Battery Management SystemsHioki Battery HiTesterHIO,3551BATTERYTEST (8655) AUTakes on-the-spot measurements of the

internal resistance, voltage and temperature of lead-acid batteries, principally for UPS and similar

applications, without needing to shut off the battery. Instantaneous results, on a three-rank scale of Pass, Warning, or Fail, using a composite decision based on the internal resistance and the voltage. Resolution of 1μΩ, necessary for high capacity batteries (of at least 500Ah). Includes Hioki 9460 clip type temperature leads.

Programma Torkel 840 Battery Load Units 288V/110A/15kW Max PRO,TORKEL-840 (8654) AU

For battery systems ranging from 12 to 250V. Discharging can take place at up to 110A. Tests can be conducted at constant current, constant power, constant resistance or in accordance with a pre-selected load profile.

ELECTRICAL POWERwww.techrentals.com.au