Serving Information. Simply.
3PAR Company Confidential
3PAR Customer Training:Software/Hardware
Overview
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
2/15
Serving Information3PAR Company Confidential
Course Objectives
At the end of this presentation the student should be able
to :
Explain the basics of 3PARs architecture
Know the numbering schemes for the InServ hardwarecomponents
Understand concepts connecting hosts to a 3PAR
Node
Explain how an InServ node precesses write and readrequests from a host
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
3/15
Serving Information3PAR Company Confidential
3PAR Value Proposition + InServ Hardware
Section Content covers:
3PAR Overview and Value Proposition
InServ InSpire Architecture
InServ Nodes
InServ drive chassis and cages
InServ storage capacities
InServ numbering schemes for nodes, cages, PCI slotsfor T Series
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
4/15
Serving Information3PAR Company Confidential
3PAR offers a smart, thin, and readytiered-storage array for resilient utility
computing.
Ideal for consolidation, data lifecycle
management, and performance-intensive applications.
What we do
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
5/15
Serving Information3PAR Company Confidential
F200 F400 T400 T800
Controller Nodes 2 2 4 2 4 2 8
3PAR Gen3 ASIC Yes Yes Yes Yes
Fibre Channel Host Ports
Optional iSCSI Host Ports
Built-in Remote Copy Ports
0 120 8
2
0 240 16
2 4
0 640 16
2 4
0 1280 32
2 8
GBs Control CacheGBs Data Cache
812
8-1612-24
8-1624-48
8-3224-96
Disk Drives 16 - 192 16 - 384 16 640 16 1,280
Drive Types 146GB, 300GB,400GB FC and/or
1TB NL
146GB, 300GB,400GB FC and/or
1TB NL
146GB, 300GB,400GB FC and/or
750GB, 1TB NL
146GB, 300GB,400GB FC and/or
750GB, 1TB NL
Max Capacity 125TB 250TB 300TB 600TB
Throughput/
IOPS (from disk)
1,300 (MB/s) /
46,800
2,600 (MB/s) /
93,600
3,200 (MB/s) /
156,000
6,400 (MB/s) /
312,000
SPC-1 BenchmarkResults
SPC-1 TBD 224,990
SPC-1 IOPS
3PAR InServ Storage ServersScalability
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
6/15
Serving Information3PAR Company Confidential
Redundant Power
Supplies (Drive Cage)
Drive MagazineRedundant Power
Supplies
Backplane
Redundant Batteries
Redundant PDUs
Drive Chassis (4U)
Controller Node
(4U)
Service Processor
Cabinet
Cabinet
Standard 19 rack footprint
40 EIA units
Built-in cable management
No Need to reserve for expansion
3PAR InSpire architecture: Cabinet
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
7/15
Serving Information3PAR Company Confidential
Hardware Product Structure for T-Series
InServT400
InServT800
InServ Storage Server BaseConfigurations (T400/T800)
Backplane, Two Controllers, One 2MCabinet (w/ PDUs)
3PAR ControllerNode
ControlCache
DataCache
3PAR Drive Chassis &Drive Magazines
40-Disk, 4 Gb/s4 x 400 10K(4Gb)
4 x 146 15K (4Gb)
4 x 750 (4Gb) NL
1 Magazine = 4 x DrivesPackaged as 4 x XXXGB DRIVE MAGAZINE
Adapters
(FC,iSCSI,GigE)
Talk to your SE or AE inregards to what drivesare currently available
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
8/15
Serving Information3PAR Company Confidential
2 to 8 per System
Add non-disruptively
Performance building block
Max host-facing adapters
Up to 4 if direct connect only
Up to 3 if mixed SAN connect
Controller Node(s)Dual-CoreXeon
2.3GHz
Dual-Core
Xeon
2.3GHz
3PAR
Gen3
ASIC
3PAR InSpire architecture: T-Class Controller Node
I/O per node
3 PCI-X buses/ 6 PCI-X slots
Preferred slot usage (in order)
Slots 0 and 2 for disk-
facing adapters Slots 5, 3, 1, and 4 for FC
host-facing or RCFCadapters
Slots 3, 1, 4 for iSCSIadapters
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
9/15
Serving Information3PAR Company Confidential
3PAR InSpire Architecture: Drive Chassis (DC3)
Above Drive Chassis contains one drive cage Each cage contains 10 drive bays
Each drive bay accommodates a single drive magazine
A drive magazine holds four disks
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
10/15
Serving Information3PAR Company Confidential
InSpire Architecture : Data Flow
When two nodes have write in Cache host can be
Acknowledged
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
11/15
Serving Information3PAR Company Confidential
InServ Numbering Systems
The Administrator should know the numbering
systems for:
Nodes
Drive Chassis
Drive Magazines
PCI slots
General Rule: Top = Starts with 0
Left = Starts with 0
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
12/15
Serving Information3PAR Company Confidential
Node Numbering
For Example:
If a T800 hasonly TWO
nodes then
they arelocated at thebottom ofcabinet and
numbered 6and 7
D
T800 - Front
SP
0 1
0
C
B
A
2 3
4 5
6 7
T400 - Front
D
0 1
C
B
A
2 3
F
E
SP
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
13/15
Serving Information3PAR Company Confidential
Fibre Channel and PCI Slot Numbering
Referencing a port on a node = Node #:PCI slot:port #
Note Numbering Exception: Fibre Channel top starts with 1
3:3:2
Node 3
On the T series node
there is a dedicatedslot for GIGE which is
slot 6
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
14/15
Serving Information3PAR Company Confidential
Review Questions for Section 1
1. What functions does the InServ eagle or osprey chip
perform?
2. How many drive magazines in an InServ drive chassis?
3. If an InServ only has two nodes, what are there numbers
if it is an T400? If it is an T800?
4. What are the hot pluggable items on an InServ?
5. How do you reference a port on a node?
6. What has to happen before 3PAR acknowledges a hostWrite?
8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1
15/15
Serving Information.Simply.
Serving Information. Simply.
3PAR Company Confidential
Thank You