    Course Objectives

    At the end of this presentation the student should be able

    to :

    Explain the basics of 3PARs architecture

    Know the numbering schemes for the InServ hardwarecomponents

    Understand concepts connecting hosts to a 3PAR

    Node

    Explain how an InServ node precesses write and readrequests from a host

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    3/15

    Serving Information3PAR Company Confidential

    3PAR Value Proposition + InServ Hardware

    Section Content covers:

    3PAR Overview and Value Proposition

    InServ InSpire Architecture

    InServ Nodes

    InServ drive chassis and cages

    InServ storage capacities

    InServ numbering schemes for nodes, cages, PCI slotsfor T Series

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    4/15

    Serving Information3PAR Company Confidential

    3PAR offers a smart, thin, and readytiered-storage array for resilient utility

    computing.

    Ideal for consolidation, data lifecycle

    management, and performance-intensive applications.

    What we do

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    5/15

    Serving Information3PAR Company Confidential

    F200 F400 T400 T800

    Controller Nodes 2 2 4 2 4 2 8

    3PAR Gen3 ASIC Yes Yes Yes Yes

    Fibre Channel Host Ports

    Optional iSCSI Host Ports

    Built-in Remote Copy Ports

    0 120 8

    2

    0 240 16

    2 4

    0 640 16

    2 4

    0 1280 32

    2 8

    GBs Control CacheGBs Data Cache

    812

    8-1612-24

    8-1624-48

    8-3224-96

    Disk Drives 16 - 192 16 - 384 16 640 16 1,280

    Drive Types 146GB, 300GB,400GB FC and/or

    1TB NL

    146GB, 300GB,400GB FC and/or

    1TB NL

    146GB, 300GB,400GB FC and/or

    750GB, 1TB NL

    146GB, 300GB,400GB FC and/or

    750GB, 1TB NL

    Max Capacity 125TB 250TB 300TB 600TB

    Throughput/

    IOPS (from disk)

    1,300 (MB/s) /

    46,800

    2,600 (MB/s) /

    93,600

    3,200 (MB/s) /

    156,000

    6,400 (MB/s) /

    312,000

    SPC-1 BenchmarkResults

    SPC-1 TBD 224,990

    SPC-1 IOPS

    3PAR InServ Storage ServersScalability

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    6/15

    Serving Information3PAR Company Confidential

    Redundant Power

    Supplies (Drive Cage)

    Drive MagazineRedundant Power

    Supplies

    Backplane

    Redundant Batteries

    Redundant PDUs

    Drive Chassis (4U)

    Controller Node

    (4U)

    Service Processor

    Cabinet

    Cabinet

    Standard 19 rack footprint

    40 EIA units

    Built-in cable management

    No Need to reserve for expansion

    3PAR InSpire architecture: Cabinet

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    7/15

    Serving Information3PAR Company Confidential

    Hardware Product Structure for T-Series

    InServT400

    InServT800

    InServ Storage Server BaseConfigurations (T400/T800)

    Backplane, Two Controllers, One 2MCabinet (w/ PDUs)

    3PAR ControllerNode

    ControlCache

    DataCache

    3PAR Drive Chassis &Drive Magazines

    40-Disk, 4 Gb/s4 x 400 10K(4Gb)

    4 x 146 15K (4Gb)

    4 x 750 (4Gb) NL

    1 Magazine = 4 x DrivesPackaged as 4 x XXXGB DRIVE MAGAZINE

    Adapters

    (FC,iSCSI,GigE)

    Talk to your SE or AE inregards to what drivesare currently available

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    8/15

    Serving Information3PAR Company Confidential

    2 to 8 per System

    Add non-disruptively

    Performance building block

    Max host-facing adapters

    Up to 4 if direct connect only

    Up to 3 if mixed SAN connect

    Controller Node(s)Dual-CoreXeon

    2.3GHz

    Dual-Core

    Xeon

    2.3GHz

    3PAR

    Gen3

    ASIC

    3PAR InSpire architecture: T-Class Controller Node

    I/O per node

    3 PCI-X buses/ 6 PCI-X slots

    Preferred slot usage (in order)

    Slots 0 and 2 for disk-

    facing adapters Slots 5, 3, 1, and 4 for FC

    host-facing or RCFCadapters

    Slots 3, 1, 4 for iSCSIadapters

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    9/15

    Serving Information3PAR Company Confidential

    3PAR InSpire Architecture: Drive Chassis (DC3)

    Above Drive Chassis contains one drive cage Each cage contains 10 drive bays

    Each drive bay accommodates a single drive magazine

    A drive magazine holds four disks

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    10/15

    Serving Information3PAR Company Confidential

    InSpire Architecture : Data Flow

    When two nodes have write in Cache host can be

    Acknowledged

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    11/15

    Serving Information3PAR Company Confidential

    InServ Numbering Systems

    The Administrator should know the numbering

    systems for:

    Nodes

    Drive Chassis

    Drive Magazines

    PCI slots

    General Rule: Top = Starts with 0

    Left = Starts with 0

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    12/15

    Serving Information3PAR Company Confidential

    Node Numbering

    For Example:

    If a T800 hasonly TWO

    nodes then

    they arelocated at thebottom ofcabinet and

    numbered 6and 7

    D

    T800 - Front

    SP

    0 1

    0

    C

    B

    A

    2 3

    4 5

    6 7

    T400 - Front

    D

    0 1

    C

    B

    A

    2 3

    F

    E

    SP

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    13/15

    Serving Information3PAR Company Confidential

    Fibre Channel and PCI Slot Numbering

    Referencing a port on a node = Node #:PCI slot:port #

    Note Numbering Exception: Fibre Channel top starts with 1

    3:3:2

    Node 3

    On the T series node

    there is a dedicatedslot for GIGE which is

    slot 6

  • 8/3/2019 3PAR Oveview of Hardware and Architect 2.3.1

    14/15

    Serving Information3PAR Company Confidential

    Review Questions for Section 1

    1. What functions does the InServ eagle or osprey chip

    perform?

    2. How many drive magazines in an InServ drive chassis?

    3. If an InServ only has two nodes, what are there numbers

    if it is an T400? If it is an T800?

    4. What are the hot pluggable items on an InServ?