14

Click here to load reader

3egm037270_en_c_12sv02_datasheet_hw

  • Upload
    eranyu

  • View
    745

  • Download
    11

Embed Size (px)

Citation preview

Page 1: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

3EGM 037270 Rev. C 15.10.2003 Page 1 of 14qÉã

éä~í

ÉJfÇ

KW=Pb

dj

MOTQ

VQa

MMPV

=oÉî

K=|_

=gìä

ó=OM

MN

MVB-PC Access Kit12SV02

MVB Service Access Kit

MITRAC® Bombardier Transportation C&C System

OverviewThe 12SV02 is a MVB access kit for the MITRAC C&C (Control and Communication)system. It exits in several versions with different HW adapter kits for connection to serviceinterfaces or direct connection to the MVB ESD+ or EMD.

PC with PCMCIA slot

SW:- PCMCIA Driver- TCN-SW

Tools: e.g.- MITRAC MAVIS- MITRAC Commissioning Tools

12SV01R0001

B1 B2

B3

B4BA

12XX05 R0001

MIC

AS-S2M

ITRAC

Tx Rx

AB

CD

EF

3EH-104078R

1Fauf N

r.:M

VBSA XV C264 A01

12XX04 R0001

C

PC-Node

PC-Node500PCC01(PCMCIA,

type 2)

12XX03 R0001/R0002

12XX033EGM036800

Fig. 1: Usage of the 12SV02

Page 2: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Data Sheet Date Rev. Status Resp. Dept. Abbr.. Date Sign. File Name

First issued

Revised

06.05.2002

07.02.200315.10.2003

A

BC

Created

Checked

Approved

PPC/EMTS

PPC/EMTS

PPC/EMST

Wp

GH

He

3egm037270_en_c_12sv02_datasheet_hw.doc

We reserve all rights in this document and the object described therein. Duplication, disclosure to third parties or utilization of itscontents are prohibited without express permission. � Bombardier Transportation GmbH 2003

MVB-PC Access Kit 15.10.2003 Page 2 of 14

The main parts of the 12SV02

� TCN-PC SW

� PCMCIA Cardware driver

� PC-Node card (12SV01 version 1)

� MVB HW Adapter Kits (not included in 12SV02 version 1)

HW Adapter Kit for EMD with 12XX03 (included in 12SV02 version 10)

HW Adapter Kit for ESD+ with 12XX03 (included in 12SV02 version 11)

HW Adapter Kit for VCU-6U and LIM with 12XX04 (included in 12SV02 version 20)

HW Adapter Kit for Multipurpose with 12XX05 (included in 12SV02 version 30)

Versions of MVB-PC Access Kit

- Generic MVB-PC Access Kit (12SV02 version 1)

- MVB-PC Access Kit for EMD with 12XX03 (12SV02 version 10)

- MVB-PC Access Kit for ESD+ with 12XX03 (12SV02 version 11)

- MVB-PC Access Kit for VCU-6U and LIM with 12XX04 (12SV02 version 20)

- MVB-PC Access Kit for Multipurpose with 12XX05 (12SV02 version 30)

Page 3: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

MVB-PC Access Kit 15.10.2003 Page 3 of 14

ContentsPage

Overview ....................................................................................................... 1Contents........................................................................................................ 3

1 Functional Description..................................................................................................................41.1 Product Structure .......................................................................................................................4

1.2 Detailed Product Structure ........................................................................................................6

2 Device Configuration ....................................................................................................................72.1 Installation Instructions ...........................................................................................................10

2.1.1 SW Installation ..................................................................................................................10

2.1.2 HW Installation..................................................................................................................10

2.2 Connection Elements...............................................................................................................10

2.3 Display Elements.....................................................................................................................10

2.4 Control Elements .....................................................................................................................10

2.5 Setting Facilities ......................................................................................................................10

2.6 Maintenance ............................................................................................................................11

3 Technical Data .............................................................................................................................113.1 Power Supply...........................................................................................................................11

3.2 Input and Output Signals .........................................................................................................11

3.3 Bus Connections......................................................................................................................11

3.4 Ambient Conditions ................................................................................................................12

3.5 Weight of MVB-PC Access Kits.............................................................................................12

4 Ordering information .................................................................................................................134.1 Problem Reports ......................................................................................................................14

5 Definitions and Abbreviations ...................................................................................................14

Page 4: 3egm037270_en_c_12sv02_datasheet_hw

MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Bombardier Transportation GmbH

Page 4 of 14 15.10.2003 MVB-PC Access Kit

1 Functional DescriptionThe MVB-PC Access Kit connects a Personal Computer with the MITRAC System forseveral functions like downloading of application SW, uploading of diagnosis data (e.g.with MAVIS) or testing and commissioning support.

It includes all HW and SW components, which are necessary for this interface.The kit is available in several versions for interfacing the different MITRAC C&Cenvironments, e.g.

- Access to MVB EMD- Access to MVB ESD+- Access to VCU-6U service interface- Access to VCU classic- Access to VCU Lite- Access to MVB FOB, as for commissioning, an optical cable is used to bridge larger

distances, e.g. between front and back console room of a locomotive, or formeasurements over several wagons in a train

1.1 Product StructureThe product has the following structure:(A) generic part, which is applicable for all target specific versions(B) target specific adapter solutions(C) target specific access kits

(C) Target specific MVB-PC Access Kit� Documentation� (A) Generic part� (Bx) Target specific part

(A) Generic part� Documentation� TCN-PC SW� PCMCIA Driver� PC-Node Card

(B) Target Specificpart� Documentation� All target specific

cables and adapters

Page 5: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

MVB-PC Access Kit 15.10.2003 Page 5 of 14

Fig. 2: Expositon of MVB-PC Access Kit for Multipurpose

Page 6: 3egm037270_en_c_12sv02_datasheet_hw

MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Bombardier Transportation GmbH

Page 6 of 14 15.10.2003 MVB-PC Access Kit

1.2 Detailed Product StructureIdentification Description / Contents Remark

A1. 3EGM037200 R0001 Generic MVB-PC Access Kit 12SV02 R0001A1.1 Documentation: data sheet, CD-ROM, installation

guide, etc.A1.2 3EGM037205 Rxxxx SW: Cardware Driver from APSoft Option has to be ordered extraA1.3 3EGM037206 Rxxxx CD-ROM with PC-Node firmware and TCN-PC-SW X: actual SW version, install. see

ch. 2.1A1.4 3EGM037100 R0001 HW: PC-Node card incl. black cable 12SV01 R0001

B1 3EGM036800 R0001 HW Adapter Kit for EMD Access 12XX03 R0001B1.1 Smd suitcaseB1.2 Documentation: 12SV02 data sheetB1.3 HW: Adapter for EMD access

B2 3EGM036800 R0002 HW Adapter Kit for ESD+ Access 12XX03 R0002B2.1 Smd suitcaseB2.2 Documentation: 12SV02 data sheetB2.3 HW: Adapter for ESD+ access

B3 3EGM036700 R0001 HW Adapter Kit for VCU-6U and LIMservice interface

12XX04 R0001

B3.1 Smd suitcaseB3.2 Documentation: 12SV02 data sheetB3.3 HW: Adapter for VCU-6U and LIM service interface

B4 3EGM037000 R0001 HW Adapter Kit for Multipurpose 12XX05 R0001B4.1 Smd suitcaseB4.2 Documentation: 12SV02 data sheetB4.3 HW: Adapter for MultipurposeB4.5 3BHC380132R0372 Optional fiber optical cable, about 2m Option has to be ordered extraB4.6 3EGM033100R0001 Adapter VCU to VCU-6U service interface 12XX11 Option has to be ordered extraB4.7 3EGM037007R0001 Optional accumulator pack including charger Option has to be ordered extraB4.8 3EGM037008R0001 Optional charger for accumulator pack Spare partB4.9 3EGM037009R0001 Optional accumulator pack Spare part

C1 3EGM037200 R0010 MVB-PC Access Kit for EMD 12SV02 R0010C1.1 Smd suitcase Shall contain everythingC1.2 Documentation: 12SV02 data sheetC1.3 A1 See aboveC1.4 B1 See above

C2 3EGM037200 R0011 MVB-PC Access Kit for ESD+ 12SV02 R0011C2.1 Smd suitcase Shall contain everythingC2.2 Documentation: 12SV02 data sheetC2.3 A1 See aboveC2.4 B2 See above

C3 3EGM037200 R0020 MVB-PC Access Kit for VCU-6U and LIMservice interface

12SV02 R0020

C3.1 Smd suitcase Shall contain everythingC3.2 Documentation: 12SV02 data sheetC3.3 A1 See aboveC3.4 B3 See above

C4 3EGM037200 R0030 MVB-PC Access Kit for Multipurpose 12SV02 R0030C4.1 Smd suitcase Shall contain everythingC4.2 Documentation: 12SV02 data sheetC4.3 A1 See aboveC4.4 B4 See above

Table 1: Product structure

Page 7: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

MVB-PC Access Kit 15.10.2003 Page 7 of 14

2 Device ConfigurationFor the connection of the PC-Node HW adapter kit to MITRAC system TRACS compatibleconnectors with shielded plastic housing are used to prevent short circuit on vehicle.

The 12SV02 R0001 is the generic MVB-PC Access kit without any HW adapter for targetconnection.

PC-Node20cm

Fig. 3: Device configuration for A1: 12SV02 R0001

The 12SV02 R0010/R0011 is designed for direct connection to MVB EMD (R0010) orESD+ (R0011). It is needed for an access of MVB segments or targets without any MVBservice interface (e.g. DCU).To connect this kit to the MVB, one MVB connector (Sub-D) at a device has to bedisconnected and the “Y-cable has to be included there in-between (see Fig. 4:).

For MVB EMD a passive T-adapter can be installed permanently on the vehicle. The12PU03 can be ordered with identification number 3EGM033800R0001. In this case the12SV02R0010 can be directly connected to this T-Adapter without disconnection of anyother connector.

directconnectionto MVB or12PU03

Repeater Box

PC-Node

5m cable

10cmY-cable

PS2 mouseadapter cable

PS2 / USBadapter

USBtype A

connector

Fig. 4: Device configuration for B1/B2: 12SV02 R0010 / R0011

Page 8: 3egm037270_en_c_12sv02_datasheet_hw

MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Bombardier Transportation GmbH

Page 8 of 14 15.10.2003 MVB-PC Access Kit

The 12SV02 R0020 is designed for direct connection to VCU-6U service interface.

PC-Node

VCU-6U withservice interface

6m cable

Fig. 5: Device configuration for B3: 12SV02 R0020

Page 9: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

MVB-PC Access Kit 15.10.2003 Page 9 of 14

For an access to VCU-Classic and VCU-Lite the 12SV02 R0030 can be used. The 0.5meter long adapter cable for connection of VCU classic and VCU-Lite, can also be usedfor MICAS-S2. In addition an optional adapter 12XX11 (order number3EGM033100R0001) can be used for connection of VCU-6U service interface with thiscable. In this case the adapter 12XX11 has to be plugged on VCU-6U service interface.

"Lemo" connector

9 V Power supply

MIC

AS-S2

PC-N

ode

CD

EF

3EH-104078R

1Fauf N

r.:M

VBSA XV C

264 A01

optional2 * 2m FOB cable

PC-Node

6m cable

9 V Power supply

110-240 V / 50-60HzAdapter or optional

accumulator packageVC

U classic

MVB Buscoupler

0.5 m cableVCU classic

VCU Liteservice

interfaceD-SUB 9female

D-SUB 9male

Fig. 6: Device configuration for B4: 12SV02 R0030

Optional a accumulator package with charger for 12SV02R0030 can be ordered:

110V-240 V / 50Hz-60Hzcharger for

accu package with"Lemo" connector

7,2 V accu packagewith "Lemo" connector

Fig. 7: Device B4.7: Optional accumulator pack with charger for 12SV02 R0030

As spare part the accumulator pack ( see Table 1 B4.9) and the charger (see Table 1B4.8) can be ordered separately.

Page 10: 3egm037270_en_c_12sv02_datasheet_hw

MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Bombardier Transportation GmbH

Page 10 of 14 15.10.2003 MVB-PC Access Kit

2.1 Installation Instructions2.1.1 SW Installation

The MVB-PC Access Kit contains several SW components on CD ROM divided for thedifferent PC operating system WIN NT 4.0 and Win 2000/XP:

Win NT 4.0:

- TCN-PC SW for WinNT 4.0 incl. PC-Node Firmware- PCMCIA Cardware driver for WinNT

For installation of PCMCIA Cardware driver and TCN-PC SW 2.2.0 for MicrosoftWindows NT4.0 see Document3egm080930d9005_en_tcn_pc_WinNT4_inst_220.pdf which is placed on CD in thedirectory of TCN-PC SW for WinNT4.

Win 2000:

- TCN-PC SW for Win2000 incl. PC-Node Firmware

For installation of TCN-PC SW 2.6 for Microsoft Windows 2000/XP see document3egm080930d9013_en_tcn_pc_Win2000_inst_260.pdf which is placed on CD inthe directory of TCN-PC SW for Win2000/XP.

2.1.2 HW InstallationPlease see the figures in chapter 2 Device Configuration.Further information can be found in the associated TCN-PC SW installation instructions.

2.2 Connection ElementsThe connectors of the Access Kit have to fit together as defined in the overview pictures ofthe different device configurations (see chapter 2 Device Configuration).

2.3 Display ElementsThe MVB-PC Access Kit itself has no display elements.

2.4 Control ElementsNot present

2.5 Setting FacilitiesAll settings will be done via MITRAC PC tools see 2.1 Installation Instructions.

Attention:The PC-Node firmware versions are not compatible to both Windows versionsNT 4.0 <-> 2000/XP all at once.

The PC-Node firmware 1.1.0.0 or 1.2.1.0 can only be used with WinNT4The PC-Node firmware 1.4.0.0 can only be used with Win2000 or XP.

Page 11: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

MVB-PC Access Kit 15.10.2003 Page 11 of 14

Please do not update PC-Node firmware version 1.1.0.0 to 1.2.1.0, if using Win NT 4.0.This is only needed if two PC-Nodes are operating on one MVB at the same time. Butsome old PC-tools will not work with the new PC-Node firmware because some additionalsettings have to be done by the PC-tool for correct operation. The PC-Node firmwareversions for standard use cases are available on the CD-ROM.

2.6 MaintenanceNot present

3 Technical Data3.1 Power SupplyThe MVB-PC Access Kits with the HW adapters 12XX03 and 12XX04 are supplied by thePC via PS2-mouse connector card.The MVB-PC Access Kit 12SV02R0030 with the HW adapters 12XX05 requires anexternal 9V power supply. Therefore a 9V power supply adapter for 110V-240V / 50Hz-60Hz is added to this package.

Power consumption: max. 1W

3.2 Input and Output SignalsNot present

3.3 Bus Connections 12SV02R0001: Generic Access Kit only, without any MVB connection

12SV02R0010: Access Kit with EMD bus connection12SV02R0011: Access Kit with ESD+ bus connection

For interconnection of this access kit the MVB line has to be disconnectedat one MVB device and the MVB Y-Adapter has to be integrated directly inthe MVB line. For MVB EMD also the 12PU03 T-branch can be used thusa disconnection of MVB is not necessary.

12SV02R0020: Access Kit with connection to MVB service port at VCU-6U. The cablehas to be connected directly on the service connector X22 on VCU-6U oron LIM connector XA22

12SV02R0030: Access Kit with bus connections for VCU-Classic and VCU-Lite (includedadapter cable) and optional for MVB FOB (2*FOB cables have to orderedextra)

Page 12: 3egm037270_en_c_12sv02_datasheet_hw

MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Bombardier Transportation GmbH

Page 12 of 14 15.10.2003 MVB-PC Access Kit

3.4 Ambient ConditionsThe Access Kits are applicable for service purpose only, not for permanent operation onvehicles.

Operating temperature: 0°C ... + 50°C

Therefore the Access Kit may not be exposed extreme ambient conditions liketemperature humidity etc.

3.5 Weight of MVB-PC Access KitsVersion Dimension Weight [g]12SV02 R0001 PCMCIA card with short 15 SUD-D adapter 90g12SV02 R0010 PCMCIA card with 5m cable, potential separation box

and 9 SUD-D TRACS compatible Y-adapter (10cm)800g

12SV02 R0011 PCMCIA card with 5m cable, potential separation boxand9 SUD-D TRACS compatible Y-adapter (10cm)

800g

12SV02 R0020 PCMCIA card with termination box, 5m cable9 SUD-D TRACS compatible connector for VCU-6U

350g

12SV02 R0030 PCMCIA card with termination box, 5m cable,multipurpose adapter box and9 SUD-D TRACS compatible adapter (0,5m)

1300g

Page 13: 3egm037270_en_c_12sv02_datasheet_hw

Bombardier Transportation GmbH MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

MVB-PC Access Kit 15.10.2003 Page 13 of 14

4 Ordering informationAll types of MVB-PC Access Kits can be ordered at:

Bombardier Transportation GmbHPropulsion and ControlsDepartment PPC SalesNeustadter Str. 6268305 MannheimGermanyFax: +49 62 13 81 52 11

First offer/order will be done typically on level C.x.A1 and B.x are typically used for spare part handling.

Identity Number 3EGM037200R0001Product Group MVB-PC Access KitProduct Type 12SV02 R0001Short Description Generic MVB-PC Access Kit

Identity Number 3EGM037200R0010Product Group MVB-PC Access KitProduct Type 12SV02 R0010Short Description MVB-PC Access Kit for EMD

Identity Number 3EGM037200R0011Product Group MVB-PC Access KitProduct Type 12SV02 R0011Short Description MVB-PC Access Kit for ESD+

Identity Number 3EGM037200R0020Product Group MVB-PC Access KitProduct Type 12SV02 R0020Short Description MVB-PC Access Kit for VCU-6U and LIM service interface

Identity Number 3EGM037200R0030Product Group MVB-PC Access KitProduct Type 12SV02 R0030Short Description MVB-PC Access Kit for Multipurpose

All 12SV02 versions will be delivered in a suitcase.

Page 14: 3egm037270_en_c_12sv02_datasheet_hw

MITRAC® - HW-Data SheetsHW Data Sheet 12SV02

Bombardier Transportation GmbH

Page 14 of 14 15.10.2003 MVB-PC Access Kit

4.1 Problem ReportsIf problems occur concerning this document or the product described by this document,please contact:

BTPC HotlineNeustadter Straße 62D-68309 MannheimGermany

Phone: +49-621-381-4310, -2099Email: [email protected]

5 Definitions and Abbreviations

EMD Electrical Medium Distance BusESD+ Electrical Short Distance Bus with potential separationLIM Line Interference MonitorMVB Multipurpose Vehicle BusTCN Train Communication NetworkVCU Vehicle Control Unit