  • 7/30/2019 3000HO0902R0411_SER_2

    1/2

    System recovery made

    faster through advancedevent monitoring

    Sequence of Event RecorderSoftware ModuleI you have ever experienced an unplanned power outage, you know

    that it can take hours or days to get the system back up and running.

    With the PowerLogic Sequence o Events Recorder (SER) Module,

    recovery time can be reduced to minutes. SER is a root-cause analysis

    sotware tool ideal or pinpointing the cause o a service disruption in

    very large, complex power systems.

    Traditionally, perorming the analysis o an outage required personnel

    to manually veriy the equipment status and then using a process

    o elimination to determine the source o the problem. SER displaystime-stamp sequence o event log inormation accurate to within 1

    millisecond and in order o the frst occurrence to show the exact

    sequence o alarming indicating the order o the events or equipment

    shutdown.

    This makes it easy to determine the source o the power outage.

    It also allows you to resolve persistent problems, clear aults, and

    take corrective action to prevent the problem rom happening again

    within a short period o time. SER takes the guess work out o system

    recovery thereby improving system availability and reliability or critical

    applications.

    Sequence o Events Recorder (SER)

  • 7/30/2019 3000HO0902R0411_SER_2

    2/2

    Features and Benefits: SER consolidates system-wide event records using Global Positioning

    Satellite (GPS) technology to synchronize the time clocks throughout

    the electrical system or accurate time stamping. Displays the millisecond time stamped events in a standard internet

    browser complete with fltering and sorting capabilities to segregateand pinpoint specifc problems in an electrical or production system.

    Captures events for entire electrical systems including devices

    such as circuit breakers and protective relay operations alongwith the shutdown sequence o generators, compressors,

    motors, etc. Supports inputs from various sources such as motors,

    generators and protective relays through a physical input/outputconnection or through Modbus communications.

    Supports OPC servers and OPC alarm and event clients forthird party sotware support

    SER is a standalone module which automatically uploads

    SER system:A SER system comprises o the SER sotware module along with

    GPS technology and inputs from PowerLogic devices and electricaldistribution equipment. PowerLogic Circuit Monitors, Power meters and ION Meters

    Circuit Breaker Status Frequency Relays

    Protective And Lockout Relays Reverse Power Relays

    Generator and Motor Status Generator Differential Relay Ground Fault

    Voltage Phase Balance DC Bus Voltage Relay

    Ground fault 50/51G

    Negative Sequence Other Relays And Status Inputs.

    Please contact your local sales representative for ordering information.

    As standards, specifcations and designs develop over time, always ask or confrmation o the

    inormation given in this publication. PowerLogic, ION, ION Enterprise, Sepam, Micrologic,

    MeterM@il and Modbus are either trademarks or registered trademarks o Schneider Electric.

    Printed on recycled paper 9-2011

    Schneider Electric - USA

    295 Tech Park DriveLaVergne, TN 37086Tel: 615-287-3500www.PowerLogic.com

    Document Number 3000HO0902R04/11

    Typically, 60% to 70%

    o downtime is used

    to identiy the source

    o an event while the

    remaining 30% to 40%is used to actually fx

    the problem. SER can

    signifcantly reduce

    the time it takes to get

    your system back up

    and running.

    SER inputmonitoring points

    Time Sync

    Global Positioning

    Satellite

    PowerLogic softwarewith SER module

    SER Services Available: System design

    Conguration and startup SER time stamping devices and

    control cabinets Sequence of Events Recorder

    browser user interace Powerlogic System Manager

    and Powerlogic ION Enterprise

    sotware integration, eventnotifcation, or custom

    advanced reports

    Reduce

    downtime