Upload
mark-colgan
View
224
Download
1
Tags:
Embed Size (px)
DESCRIPTION
Access and Control - Dirak E-LINE Catalogue
Citation preview
by DIRAK
Mechatronic Access Control for Industrial Enclosures
by DIRAK
2 E-LINE by DIRAK | Catalog 2012
by DIRAK
DIRAK is an innovation company that designs, manufactures and markets mechanical and mechatronic enclosure hardware using the latest technologies for latches, locks, hinges, handles and gaskets. Our experienced engineers and product designers work closely with our customers transforming their requirements into cost saving and innovative solutions.
Founded in 1991, DIRAK is now a worldwide enterprise. At our facilities in Germany, the USA and Asia, we employ 450 people who design, produce our quality products and provide engineering support to our customers. DIRAK employs a worldwide sales network through our subsidiaries and sales partners, ensuring that our products and services are close to our customers.
E-LINE by DIRAK is DIRAK’s line of mechatronic system solutions that are designed to give a high level of security at the rack or enclosure. E-LINE is a critical component of the DIRAK innovative line of products.
About us
Standard SolutionsE-LINE by DIRAK products were developed to address three application areas:
1. System and access control solutions for monitoring server racks. With more than ten years of experience, DIRAK is the market leader in this sector.
2. Locking solutions for enclosures in outdoor and publicly accessible areas including special protection against vandalism and unauthorized access. With vast experience in this area, DIRAK has numerous installations globally.
3. System solutions for industrial enclosure applications. DIRAK solutions can be easily installed and provide flexible, reliable access control solutions for a wide range of enclosures that store sensitive material.
Custom SolutionsThis is our strength. DIRAK develops custom access control solutions that meet our customers’ individual requirements. This begins with consulting and continues to an individualized solution and finally to implementation.
Worldwide ServiceDIRAK has worldwide sales and technical representation. Please contact us, for immediate access to a knowledgeable and highly trained DIRAK representative in your area.
E-LINE by DIRAK | Catalog 2012 3
Philosophy
E-LINE by DIRAK is a mechatronic access control, monitoring and management system
E-LINE by DIRAK is based on RFID transponder technology. This allows all access to be identified and authorized.
Our Range of Products and Services• Locking systems for individual enclosures, racks or entire
computer centers• Support in choosing the right system for your application• Hardware and software• Integrating the solution into your particular security system• Support in installing the systems• Ongoing support and maintenance for the systems after
installation.
E-LINE by DIRAK consists of three main components that complement each other: the actual physical lock, its integration into your IT network, and the associated Administration Suite software to monitor the system.
E-LINE by DIRAK Locking Solutions are available in various configurations for:
Server racks (MLR Series)•Stand-alone•Networked (online systems with real-time visualization)• IP addressable •With software
Universal applications (MLU Series)• Stand-alone or networked•As a single or multipoint locking solution•With software (online systems with real-time visualization)• Integrated into an existing management system•As a complete solution with the Administration Suite software
Enclosures in outdoor and publicly accessible areas (MLE Series) •Stand-alone or networked•With single or dual cylinder key locks•With emergency access
by DIRAK
4 E-LINE by DIRAK | Catalog 2012
Impression
Logistics
Electronicproduction
DIRAK Headquarters
E-LINE by DIRAK | Catalog 2012 5
Content
About us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Impression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Secure Protection for Your Data: You Can Trust E-LINE by DIRAK Solutions . . . . . . . . . . . . .6
Data Center and Computer Center Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
IT Racks: Installing the Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
MLR – Mechatronic Lock for Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
MLR1000: Data Center with Existing Management System . . . . . . . . . . . . . . . . . . . . . 17
MLR3000: Solutions for Centralized Data Structures . . . . . . . . . . . . . . . . . . . . . . . . . 19
MLR5000: Solutions for Decentralized Data Structures . . . . . . . . . . . . . . . . . . . . . . . . 21
Administration Suite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
New Administration Suite Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MLU – Mechatronic Lock for Universal Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
MLU1000: Mechatronic Lock for Universal Applications . . . . . . . . . . . . . . . . . . . . . . . 28
MLU1001: Alternative für mechanische Verschluss lösungen . . . . . . . . . . . . . . . . . . . . . 30
System Overview MLU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
MLU3000: Locking solution for centralized server cabinet enclosures housing various cabinet types. . . . . . 34
MLU5000: Locking solution for decentralized server cabinet enclosures housing various cabinet types. . . . . 37
MLA – Mechatronic Lock Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Transponder Cards with Your Corporate Design . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MLE – Mechatronic Lock for Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
MLE1100: “OR” Opening with One Profile Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . 47
MLE2100: “AND” Opening with One Profile Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . 49
MLE1200: “OR” Opening with Dual Profile Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . 51
MLE2200: “AND” Opening with Dual Profile Cylinders . . . . . . . . . . . . . . . . . . . . . . . . 53
ELINEbyDIRAK.de: Homepage with Configurator and Installation Aids . . . . . . . . . . . . . . . 55
by DIRAK
6 E-LINE by DIRAK | Catalog 2012
Secure Protection for Your Data: You Can Trust E-LINE by DIRAK Solutions
In recent years, the public has become much more aware that sensitive data, especially customer data, must be absolutely secure.
The organization and implementation of data protection measures often neglect physical access protection. It is not only newsworthy hacker attacks that lead to security violations, but simply taking advantage of inadequately protected physical access to the data. This type of security breach can be prevented through access control mechanisms and comprehensive monitoring and record keeping.
There is more at stake than just data protection and misuse. The economic damage can be enormous for a company when servers are down for any reason.
Stolen or misused data means loss of trust and damage to your company’s image. When reports are in the media, it’s already too late. The costs of the damage can be enormous, even for small companies. Data theft can potentially lead to bankruptcy if customers have lost faith in your company and in a very valuable asset … security.
This is where DIRAK has a decided advantage. Every company has specific requirements for the security of their systems, and DIRAK can help implement them. Whether it is a single application, or a comprehensive overhaul, DIRAK has a solution to fit your company’s needs.
The modular E-LINE by DIRAK concept enables DIRAK to provide the best security solution for your company’s particular application.
E-LINE by DIRAK | Catalog 2012 7
Data Center with Centralized Structure
These centers have a high density of racks with large amounts of data and high management demands. A large number of racks might be in one room or are combined into groups known as “cooling alleys.” Physical data protection in such facilities must be centrally controlled and easily manageable.
Examples are shown below.
Information on lock status. In addition to constantly monitoring, documenting and regulating access to their server racks, those responsible for security must have information on the lock status of the racks at all times. For situations such as replacement or maintenance of devices, access to individual racks must be controlled individually.
“Four Eyes” principle. Individual racks containing servers that handle highly sensitive data require a heightened security level. One alternative is to utilize the “Four Eyes” principle – the requirement that two persons must be approved and present for a rack to be accessed
Local display and the network. Service technicians must be able to quickly find the server requiring maintenance and to identify problems in the room. Therefore, the status of the lock must be displayed directly on the rack. Exceeding a time limit allowed for a rack to be open must be reported to both the technician at the rack and to the administration software.
Easily scalable. Expanding or changing the number of racks must be fully supported by the management system. All changes must be easily integrated into existing networks.
Our Solution: E-LINE by DIRAK MLR Series products – for high availability and low project costs.
For additional installation cutouts and latching mechanisms please see the ELINE by DIRAK MLU series products.
Data Center and Computer Center Applications
by DIRAK
8 E-LINE by DIRAK | Catalog 2012
Our Solution: E-LINE by DIRAK MLR Series products – for high availability and low project costs.
For additional installation cutouts and latching mechanisms please see the ELINE by DIRAK MLU series products.
These data center structures have attributes and requirements similar to centralized data centers. However, racks in different buildings or geographic locations place additional security requirements on access control systems.
Decentralized on site servers are often used to support the central server structures. These decentralized servers are exposed to special risks. Although they are protected by locked enclosures, risks lie in the complex procedures for issuing keys, duplicating them upon loss and reclaiming them when no longer needed. With an RFID-based mechatronic solution these disadvantages are avoided
Examples of requirements for decentralized structures are:
Constant monitoring. It is particularly important to have constant monitoring, documentation and information on the status of the racks. In addition, those responsible for security must also monitor individual racks in order to avoid risk of unauthorized access.
Granting access individually. Granting or declining access to the racks must be done individually. This is important for routine replacement and maintenance. Racks containing more sensitive data and requiring additional access control, could employ the “Four Eyes” principle to achieve a higher level of security.
In decentralized server rooms, service technicians should be able to identify problems directly at the racks. For example, information indicating that the opening time has been exceeded must be provided to technicians on site and the administration software.
Administration across country borders. Decentralized data centers are often managed from a central location. Therefore, it must be possible to manage access to racks distributed across borders and internationally. This requires monitoring, documenting and control across different time zones.
Data Center in Decentralized Structures
E-LINE by DIRAK | Catalog 2012 9
Our Solution: E-LINE by DIRAK MLR Series products – for high availability and low project costs.
For additional installation cutouts and latching mechanisms please see the ELINE by DIRAK MLU series products.
Stand-alone Racks
Single racks are often subject to special risks. They are most commonly located in adjacent offices with no special security. Even though they may be protected with locks, the risk for them is inherent in the way keys must be managed. Making and issuing keys, their loss or duplication, and reclaiming them from employees or service technicians requires a very complex, time-consuming key management system.
The card system of an electromechanical solution avoids these disadvantages.
by DIRAK
10 E-LINE by DIRAK | Catalog 2012
Our Solution: E-LINE by DIRAK MLR Series products – for high availability and low project costs.
For additional installation cutouts and latching mechanisms please see the ELINE by DIRAK MLU series products.
Applications in Co-Location CentersCo-location centers are data centers in which separate, distinct customer areas are managed together. Such centers are becoming increasingly popular because customers can use them for racks they manage themselves. Although the co-location center may provide access control to the server room via an entrance system requiring proof of authorization, the servers of the individual customers must be additionally secured against unauthorized access
This is often handled by installing fenced cages equipped with separate access control systems. However, inside the cages the problem still exists when a technician does not have reason to access all the racks. The person responsible for security must, in addition to admitting customers to the facility, have constant monitoring, documentation and access control to the individual server racks. With the right solution, the co-location center can provide its customers with complete documentation of all events occurring at each rack.
E-LINE by DIRAK | Catalog 2012 11
The need to secure and control access to enclosures, cabinets and drawers containing toxic, hazardous or sensitive substances as well as highly sensitive information has grown. Keyed systems have become outmoded due to the risks of lost and copied keys.
Secure and Monitored Locking System
Our Solution: E-LINE by DIRAK MLU products
by DIRAK
12 E-LINE by DIRAK | Catalog 2012
These enclosures are subject to special risks as they generally are not under constant surveillance and can be located in remote areas. Enclosures in outdoor areas that are freely accessible require high security locks to protect them against vandalism and theft of raw materials (e.g., copper) which results in failure of the technical infrastructure.
With the right access control system, investments in traditional keyed systems and their complex management are not required. In addition, common oversights, such as a service technician who has not closed the door properly, are immediately apparent.
Effective physical protection and continual monitoring of the enclosure door can ensure the safety and viability of your technical equipment.
Enclosures in Outdoor and Publicly Accessible Areas
Our Solution: E-LINE by DIRAK MLE Series products
ø 4,5
7050
34,7±0,1
36x variable 51 - 53
25+0,1
50+0
,150
+0,1
50+0
,1
5
Türmitte
E-LINE by DIRAK | Catalog 2012 13
Cam latch Rod latch Offset latch
The swinghandle is connected to a 3-point cam. An optional round rod system can be used to provide multipoint latching.
The swinghandle actuates the housed rod latch mechanism, which slides the vertically mounted flat rods up and down into the door frame (2-point latch).
The swinghandle actuates the latching slide mounted slightly to the side of the handle. A rod system actuated from the side is typical for the offset latch.
IT Racks: Installing the LatchTo help identify the mechanical adapter components needed for your latching system, we have illustrated the most commonly used latching systems here. If you do not see your particular system, please feel free to contact us. There is a wide variety of
other adapter components available, and we will find the right solution for your system. For additional installation cutouts and latching mechanisms please see the ELINE by DIRAK MLU series products starting on page 27.
50+0,1 mm
50+0,1 mm
50+0,1 mm
25+0,1 mm
50+0,1 mm
50+0,1 mm
50+0,1 mm
25+0,1 mm
Door panel cutout (type C) Door panel cutout (type C)
Length: 252 mm
by DIRAK
14 E-LINE by DIRAK | Catalog 2012
MLR – Mechatronic Lock for RacksUniting aesthetics, ergonomics and function, the ergonomically shaped handle with matt chrome finish is elegantly designed to both look good and feel good. The chrome and black housing is an attractive, high quality handle that provides long-lasting, worry-free security.
The LEDs integrated into the housing provide local signaling of alarms and authorization status directly on the handle. Technicians on site see the same information as shown in the Administration Suite software in the control center.
The two LEDs positioned above and below the chrome handle are illuminated and only consuime a small amount of power. This enables the status of the handle to be clearly and quickly determined even when seen from a distance of several yards.
The upper LED indicates the current status of the handle, such as “Ready for operation” (handle does not spring out automatically), or “Access not authorized.” The lower LED indicates whether the environment of the handle is within a customer defined temperature range.
Width: 40 mm
Height: 27 mm
E-LINE by DIRAK | Catalog 2012 15
Do you want to integrate the E-LINE by DIRAK product into an existing security system?
Do you want to use software for administration of your access control system, or do you prefer electronic verification without software (stand-alone)?
Are your server cabinets located in different rooms, floors and/or buildings?
The optimal solution for you depends on your exact requirements. By combining various E-LINE by DIRAK solutions, you can achieve the optimal security system for your infrastructure.
Key Questions for Product Selection
with software
without software
no yes
Operational Status Indication
green steady: Temperature OK
blue steady: Handle ready for
operation
blue steady: Handle ready for
operation
red flashing: Temperature alarm
red flashing: Temperature alarm
green steady: Temperature OK
green flashing: “Green Period” (free access w/o media)
green steady: Temperature OK
red flashing: Alarm
green steady: Temperature OK
green steady: Access authorized
green steady: Temperature OK
orange steady: Handle opened
green steady: Temperature OK
red steady: Access not authorized
red steady: Access not authorized
MLR3000
MLR1000
MLR3000 MLR5000
no yes
by DIRAK
16 E-LINE by DIRAK | Catalog 2012
Administration Suite Software
With the MLR3000 and MLR5000 systems, the only software that can be used to monitor and track access events is the E-LINE by DIRAK Administration Suite. This software has been designed specifically to meet the needs of data center operators. For details, please see the separate Administration Suite section later in this catalog.
MLR1000 MLR3000 MLR5000
The MLR1000 features a hardware interface enabling it to be integrated into an existing facility management system. When the dry (voltage-free) contacts of the external system close, the MLR1000 switches into a “ready to be opened” state. However the handle itself does not open until the user presses a button on the handle and opens it manually.
The MLR3000 is especially well suited for rooms in which a large number of server cabinets are installed (centralized server cabinet structure). With just one IP address, up to 32 swinghandles can be managed individually via an E-LINE by DIRAK Gateway.
The MLR5000 was developed to monitor and manage decentralized server structures conveniently from a central location. This is made possible by assigning each swinghandle its own unique IP address.
Is customer-provided 3rd-party software needed?
depends on customer’s software No No
Administration Suite?
No Yes Yes
Emergency power?
Yes Yes Yes
Authorization method
depends on customer’s software Transponder card Transponder card
IP addressable?
No No Yes
Events logged?
depends on customer’s software Yes (in combination with Administration Suite)
Yes (in combination with Administration Suite)
User profiles
depends on customer’s software Yes (in combination with Administration Suite)
Yes (in combination with Administration Suite)
“Four-Eyes” principle
depends on customer’s software Yes (in combination with Administration Suite)
Yes (in combination with Administration Suite)
Stand-alone option
depends on customer’s software Yes No
System Overview
E-LINE by DIRAK | Catalog 2012 17
Information regarding latching and installation mechanisms can be found on page 13.
MLR1000: Data Center with Existing Management System
The MLR1000 is suitable for applications in data center rooms that already have a facility management system with access control.
The MLR1000 features a hardware interface that enables it to be integrated into the existing facility management system. The handle can only be opened after the external system closes dry contacts connected to the handle.
When activated, the MLR1000 switches into a “ready to be opened” state.
During this time window, the user can open the MLR1000 manually by pressing a button on the handle.
MLR1000 Technical Specifications
Handle electronics
Two-part hardware system E-LINE by DIRAK MLR1000 Swinghandle and MLR1000 Box
Indicators Status LED
MLR1000 Box
Housing Interface unit in plastic housing, mountable with screws or self-adhesive pad
Sheet thickness 1.5 – 2.0 mm plus powder coating
Moment of torque (recommended) screws for mechanic (top) = 1.0 – 1.2 Nm, screws for cab (bottom) = 0.4 Nm (“WERA” moment of torque tool is available in our accessories product line)
Supply voltage 12 V DC ± 10%, screw terminals
Standby current (system ready) 40 mA (DC)
Maximum current (at relay pick-up) 410 mA (DC)
Duty rating Continuous
Relay activation 12 V DC
Actuation time 3 seconds maximum
Output contact rating 250 V AC, 2 A
Mounting position any
I/O connections Screw terminals, 2.5 mm2
Connection cable (interface box -> handle electronics)
8-pin; 350 cm; UL-approved, 26 AWG stranded wire; RJ45 connector molded onto one end; crimped JST ZHR-8 connector on other end
Temperature range -20°C ... +70°C
by DIRAK
18 E-LINE by DIRAK | Catalog 2012
The MLR1000 can be controlled via dry contacts in your facility management system. When the contacts are closed, the handle switches to “ready to be opened” state.
Variant 1: Connect the dry, switching contacts of your facility management system to terminals 1 and 3 of the MLR1000 interface box.
Variant 2: To open the handle activate terminals 1 and 2 with 12 - 24V DC.
Part Number Description
610-9539.07-07101 MLR1000 for cam latch*
610-9501.07-07101 MLR1000 for rod latch*
610-9507.00-07101 MLR1000 for offset latch*
*See IT-cabinets – the mechanisms on page 13
Interface Unit Terminal Strip
The auxiliary terminals shown here enable you to utilize the full range of functions provided by the MLR1000:
1.-3. Opening Options4.-5. Handle status contact6.-7. Solenoid status contact
Wiring the MLR1000
1
1
2
2
Existing Management Systemdry/potential free contact
112V DC 2 3 4 5 6 7
MLR1000 Box
HANDLE
+ -
Existing Management System
112V DC 2 3 4 5 6 7
MLR1000 Box
HANDLE
+ -
12 - 24V DC
+-
External power supply or
existingManagement Systemwith the possibility providing power to
external components
Power requirementDIRAK power supply
112V DC 2 3 4 5 6 7
MLR1000 Box
HANDLE
+ -
112V DC 2 3 4 5 6 7
MLR1000 Box
HANDLE
+ -
12V DC
+-
112V DC 2 3 4 5 6 7
MLR1000 Box
HANDLE
+ -
vol
tage
sup
ply
varia
nts
Ope
ning
varia
nts
E-LINE by DIRAK | Catalog 2012 19
Information regarding latching and installation mechanisms can be found on page 13.
MLR3000 Technical Specifications
Handle electronics
Two-part hardware system E-LINE by DIRAK Swinghandle and Reader Unit
Indicators Multicolor status LED
Reader For 125 kHz transponder (HID 26-bit system); optional: 13.56 MHz (MIFARE)
Reader
Housing Reader unit in plastic housing, mountable with screws or self-adhesive pad
Sheet thickness 1.5 – 2.0 mm plus powder coating
Moment of torque (recommended) screws for mechanic (top) = 1.0 – 1.2 Nm, screws for cab (bottom) = 0.4 Nm (“WERA” moment of torque tool is available in our accessories product line)
Supply voltage 12 V DC ± 10%, low-voltage jack
Standby current (system ready) 40 mA (DC)
Maximum current (at relay pick-up) 440 mA (DC)
RS-232 interface RS-232 lines (RXD ,TXD, GND, Reader present, PC present), 38,400 Baud
Connection cable (Reader -> handle electronics) 8-pin; 350 cm; UL-approved, 26 AWG stranded wire; RJ45 connector molded onto one end; crimped JST ZHR-8 connector on other end
Relay output (screw terminals) 2.5 mm², screw on insertion side; Relay contact: 12 V, 3 A, 60 W, 120 VA, terminals 3-5
Door contact input (screw terminals) 2.5 mm², screw on insertion side, terminals 1 and 2
RS-485 interface RS-485 lines from E-LINE by DIRAK Gateway (+/A, -/B), 38,400 Baud
Storage capacity for transponder cards 2,000 cards + 1 master transponder
Storage capacity for events 500 events (ring buffer)
Storage capacity for time profiles 30 profiles
Integrated real-time clock With buffering for up to 60 min. at 25°C
Temperature range -20°C ... +70°C
The MLR3000 is especially well suited for data centers with a large number of racks.
The MLR3000 solution, which is based on the protocols and wiring of an RS-485 BUS system, is well suited for use in large data centers. The MLR3000 is also the ideal choice for cooling alleys, which are becoming increasingly popular due to energy saving considerations.
Cabling and Network Configuration of the MLR3000: Communications to the swinghandle are handled through the E-LINE by DIRAK Gateway. The gateway unit is the interface between the RS-485 BUS and the Ethernet/LAN network, and is responsible for converting data packets
and forwarding them to the RS-485 BUS. Node Points are used to daisy-chain from the gateway to each swinghandle. One gateway supports up to 32 MLR3000 handles.
The E-LINE by DIRAK Series mechatronic swinghandles and Administration Suite software offer you a convenient, reliable access control solution for your data and server cabinets.
The Administration Suite software enables security personnel to monitor and control all access to racks conveniently from a PC.
MLR3000: Solutions for Centralized Data Structures
by DIRAK
20 E-LINE by DIRAK | Catalog 2012
1 2 3 4 5 6 7
GATEWAY MLR3000
LAN OUTPUT CONFIG
READER MLR3000
CX
HANDLE
CONFIG
Junction box
INPUT MODUL OUTPUT
Power supply
Power supply
CN cableCAT5 cable
SWITCH/ETHERNET NETWORK
CAT5 cable
Control cable
READER MLR3000
CX
HANDLE
CONFIG
Junction box
INPUT MODUL OUTPUT
Power supply
CN cable
CN cable CN cable CN cable
Control cable
...
Administration Suite
MLR3000 MLR3000
Part Number Description Read Frequency
610-9739.00-00000 MLR3000 for cam latch* 125 kHz (optional 13,56 MHz)
610-9701.00-00000 MLR3000 for rod latch* 125 kHz (optional 13,56 MHz)
610-9707.00-00000 MLR3000 for offset latch* 125 kHz (optional 13,56 MHz)
*See IT-cabinets – the mechanisms on page 13
Reader Unit Terminal Strip
The auxiliary terminals shown here enable you to utilize the full range of functions provided by the MLR3000:
1 GND2 Binary input (door contact)3 Normally-open contact of the relay (NO)4 Normally-closed contact of the relay (NC)5 Common contact of the relay6 unused7 unused
E-LINE by DIRAK | Catalog 2012 21
Information regarding latching and installation mechanisms can be found on page 13.
MLR5000 Technical Specifications
Handle electronics
Two-part hardware system E-LINE by DIRAK Swinghandle and Reader Unit
Indicators Multicolor status LED
Reader For 125 kHz transponder (HID 26-bit system); optional: 13.56 MHz (MIFARE)
Reader
Housing Reader unit in plastic housing, mountable with screws or self-adhesive pad
Sheet thickness 1.5 – 2.0 mm plus powder coating
Moment of torque (recommended) screws for mechanic (top) = 1.0 – 1.2 Nm, screws for cab (bottom) = 0.4 Nm (“WERA” moment of torque tool is available in our accessories product line)
Supply voltage 12 V DC ± 10%, low-voltage jack
Standby current (system ready) 40 mA (DC)
Maximum current (at relay pick-up) 440 mA (DC)
Current increase when X-Port in use 125 mA (DC)
RS-232 interface RS-232 lines (RXD ,TXD, GND, Reader present, PC present), 38,400 Baud
Connection cable (Reader -> handle electronics) 8-pin; 350 cm; UL-approved, 26 AWG stranded wire; RJ45 connector molded onto one end; crimped JST ZHR-8 connector on other end
Relay output (screw terminals) 2.5 mm², screw on insertion side; Relay contact: 12 V, 3 A, 60 W, 120 VA, terminals 3-5
Door contact input (screw terminals) 2.5 mm², screw on insertion side, terminals 1 and 2
TCP/IP interface Ethernet, 10100 autosense, up to 100 MBaud
Storage capacity for transponder cards 2,000 cards + 1 master transponder
Storage capacity for events 500 events (ring buffer)
Storage capacity for time profiles 30 profiles
Integrated real-time clock With buffering for up to 60 min. at 25°C
Temperature range -20°C ... +70°C
MLR5000: Solutions for Decentralized Data Structures
E-LINE by DIRAK makes it easy to keep your data secure even when racks are distributed across different rooms and/or buildings. For these situations, the E-LINE by DIRAK MLR5000 is the ideal solution.
The special feature of this handle is that every rack can be configured with its own IP address, and is accessible directly and singly over the network.
Because they are integrated into the Ethernet network, there is no need for a separate BUS system, which makes this configuration the ideal access control solution for data center racks located on different floors or in different buildings.
Cabling and Network Configuration of the MLR5000: Communications to the swinghandle are handled via the TCP/IP protocol. Every handle is assigned its own static IP address and is accessible at all times over the network. No separate BUS system is required for the MLR5000 because it uses the existing Ethernet LAN. This makes installation of the system easier and faster.
E-LINE by DIRAK Series mechatronic swinghandles and Administration Suite software ensures convenient, reliable access control for all data racks. Security administrators can manage the access control system from their desks.
by DIRAK
22 E-LINE by DIRAK | Catalog 2012
1 2 3 4 5 6 7
Administration Suite
Power supply
SWITCH/ETHERNET NETWORK
SWITCH/ETHERNET NETWORK
Control cable
Power supply
Control cable
CAT5 cable
CAT5 cableCAT5 cable
READER MLR5000
LAN
HANDLE
CONFIG
READER MLR5000
LAN
HANDLE
CONFIG
READER MLR5000
LAN
HANDLE
CONFIG
Power supply
Control cable
...
MLR5000 MLR5000 MLR5000
Reader Unit Terminal Strip
The MLR5000 offers various configuration alternatives. By connecting appropriate equipment to the auxiliary terminals shown here, you can utilize the full range of functions it provides:
1 GND2 Binary input (door contact)3 Normally-open contact of the relay (NO)4 Normally-closed contact of the relay (NC)5 Common contact of the relay6 unused7 unused
Part Number Description Read Frequency
610-9639.00-00000 MLR5000 for cam latch* 125 kHz (optional 13,56 MHz)
610-9601.00-00000 MLR5000 for rod latch* 125 kHz (optional 13,56 MHz)
610-9607.00-00000 MLR5000 for offset latch* 125 kHz (optional 13,56 MHz)
*See IT-cabinets – the mechanisms on page 13
E-LINE by DIRAK | Catalog 2012 23
Administration SuiteThe Administration Suite is E-LINE by DIRAK’s security management software. It fulfills all the requirements for monitoring and controlling the E-LINE by DIRAK MLR Locking Systems, and it provides additional useful functions beyond just simple administration.
Data misuse and theft are among the greatest risks a company or organization can face. When servers are down and unavailable due to interruptive updates, repairs or maintenance, damage and additional costs can result. Implementing effective protection measures are part of every risk management program.
Companies require more than just installing appropriate locking systems for their risk management programs. They must also ensure that their operations are continually documented reliably and comprehensively. Banks and insurance companies require this documentation for damage claims and to secure investments and risks.
ELINE by DIRAK’s Administration Suite software provides for the effective logging of all security events with full access control.
Monitoring and Managing with the Administration Suite. In the Administration Suite software, which is continually being upgraded and improved, DIRAK has integrated and incorporated many features based on customer feedback and practical experience in the field. Customer satisfaction is high.
With the Administration Suite, you can administer, document and protect access to all racks. One has full control over all cabinets and enclosures secured with E-LINE by DIRAK systems, while at the same time having a high degree of flexibility.
The Administration Suite software offers many features: comprehensive alarm management, the ability to manage systems in different time zones, administration of different facilities from one user interface and the documented XML interface, which enables data to be imported and exported.
Flexible, clearly structured and user-friendly, the intuitive user interface makes the software an easy-to-use and effective management system for your data and server racks providing security with the MLR3000 or MLR5000 systems.
by DIRAK
24 E-LINE by DIRAK | Catalog 2012
New Administration Suite Functions
1. E-mail function has been added for efficient administration of access and blocking control.
2. Administration of rack-groupings in data centers is improved using color coded information fields.
3. Can be configured to allow super users continuous (at will) access to a specific unit.
4. MLR3000/5000 are connected via an SNMP interface to an existing management system which allows the status of the handles to be monitored and controlled using Administration Suite Software.
5. Transponder use is expanded by integrating 13,56 MHz Mifare DesFire ev1 transponders.
6. Administration of equipment groups is improved to provide a quick overview which is especially helpful when equipment is distributed over several rooms, floors or buildings.
7. A new “access period” function has been added allowing periods of time in which the handle is available for access. During these time periods, no additional media (key, transponder, etc.) is needed for access.
8. Number of access attempts (handle openings) during the “access period” can be limited.
9. A new diagnostics tool has been developed to detect errors due to sudden shutdown of database servers. This new tool aborts processes that cannot be executed and restores normal system status.
Task AdministrationThe Administration Suite software provides the ability to automate specific tasks. Log data can be saved and sent via email periodically as desired -- one time, daily, weekly, monthly, etc. The same is true for remote access, access periods and blocking periods. All tasks can be timed so that they occur once, daily, weekly or monthly at specific times. Individual tasks within Task Administration can be edited or deleted at any time.
Backlight Colors (MLR3000/MLR5000/MLU3000/MLU/5000. All LED fields for these handles can be individually configured. In large data or co-location centers, high volume of server cabinets can cause confusion. The option to have different backlight colors can provide a better overview. Client or group specific backlights offers simple identification. It is also possible to select intermittent flashing in combination with different colors for quick identification. Temperature and handle status indicators are two LED signals that can be on or off as desired.
E-LINE by DIRAK | Catalog 2012 25
1. The Administration Suite is easy to use yet provides a comprehensive set of tools.
2. The Administration Suite provides an extensive range of alarm and system messages.
3. The Administration Suite can automatically forward alarm and/or system messages to any e-mail address you specify.
4. The software enables you to create and maintain central access schedules and detailed access administration.
5. Where elevated security levels are needed, the “Four Eyes” principle can be utilized, requiring that the device can be opened only when two people provide appropriate authorization at the same time.
6. The Suite can take over the entire administration of several different facilities.
7. All actions are logged as “Log Events,” which can also be exported.
8. In the event authorization media is lost or stolen, it can be blocked for further use in the system without incurring costs to replace the actual lock system.
9. Since its communications are event-triggered rather than polled, network traffic is greatly reduced.
10. All data communications between the hardware, server and client are encrypted.
11. The Administration Suite runs on Windows 2000®, Windows 7®, Windows Server 2003®, Windows Server 2008® and Citrix®.
12. The software provides for the administration of different users with different access profiles.
13. The Administration Suite is client/server capable, which means it can be installed on a central server PC and used from remote client PCs.
14. The Administration Suite’s Web Client enables you to access the Suite at all times over the internet with a simple browser. You can even use the access management system from smartphones and tablet PCs when you’re on the go.
15. The software logs all changes users have made to the system.
16. The software prevents inadvertent patching of the server when data backup is in progress (defined “blocking period”).
17. The software graphically displays the status of all swinghandle stations in real-time.
18. The software allows exception schedules with different access rules to be defined for special days such as holidays.
19. Several different time profiles can be defined, during which access is allowed or completely blocked.
20. The Administration Suite is multi-language capable, which can be chosen at runtime, and is thus suitable for worldwide use.
21. Thanks to its modular design and open-interface architecture, the Administration Suite can be expanded at will, and even implemented for third-party systems.
22. It provides a documented XML interface for implementation in third-party systems.
23. Automated task administration with e-mail function for efficient administration of access and period blocking control.
24. Improved administration of rack-groupings in data centers using color coded information fields.
25. Configuration available for super users who have continuous access to a specific unit.
26. MLR3000/5000 are connected via an SNMP interface to an existing management system which allows the status of the handles to be monitored and controlled using Administration Suite Software.
27. Expands transponder use by integrating 13,56 MHz Mifare DesFire ev1 transponders.
28. Improved administration of equipment groups to provide a quick overview which is advantageous when equipment is distributed over several rooms, floors or buildings.
29. Defined “access periods” in which the handle can be opened with no additional media.
30. Limitations on the number of access attempts within the access period.
31. New diagnostics tool to detect errors due to sudden shutdown of database servers. The tool aborts processes that cannot be executed and restores normal system status.
32. Creating password and login guidelines in Administration Suite software. In creating passwords, numbers, capital letters, lower case letters and special symbols can be used and configured accordingly. For login, the number of access attempts and time period required between attempts can be specifically defined.”
Special Features of the Administration Suite
by DIRAK
26 E-LINE by DIRAK | Catalog 2012
The integrated Web Client makes it possible for any number of users to connect remotely to the Administration Suite server via a simple web browser.
In addition to being able to use the Administration Suite remotely via LAN or WLAN from local computers, it can also be accessed via cell phone data networks.
Any device with a browser function (iPad®, tablet PC, iPhone®, Blackberry®, etc.) can be used to access the Administration Suite without having to install additional software on the device.
This enables security administrators to manage the access control system for server/data cabinets at any time, no matter where they happen to be at the moment.
Integrated Web Client
GATEWAY MLR3000
LAN OUTPUT CONFIG
READER MLR3000
CX
HANDLE
CONFIG
Junction box
INPUT MODUL OUTPUT
Power supply
To the next junction box
Power supply
CN cable CN cable
...
Administration Suite Server
Administration Suite Client
Administration Suite Client
Administration Suite Client
Administration Suite Client
SWITCH/ETHERNET NETWORK
SWITCH/ETHERNET NETWORK
CAT5
READER MLR5000
LAN
HANDLE
CONFIG
Power supply
Control cable
CAT5CAT5
CAT5
CAT
5
Control cable
CACHE DATABASE
SSL2)
SSL3) AES1)
1) AES with both-way authentication2) SSL Service to Service
Ethernet TCP/IP
RS485 BUS
WLAN
3) SSL Client to database
SSL Secure socket layer
AES advanced encryption standard
AES1)
AES1)
Part Number Description
608-6801.00-00000 Administration Suite Software
E-LINE by DIRAK | Catalog 2012 27
MLU – Mechatronic Lock for Universal Applications
The MLU locks offer a mechatronic locking system for universal use. They are ideal for indoor applications where drawers, server cabinets and other enclosures must be secured. They can also be used in outdoor applications where the lock is located inside the sealed area.
The MLU Series is the most versatile solution for securing a wide range of enclosure types. The compact design makes it ideal for applications where space is limited. The basic MLU locks can be complemented with visualization units.
Installed inside the enclosure, the MLU lock cannot be seen from the outside and does not provide a point of attack for forced entry.
Adding a visualization unit to the MLU lock will provide the same functionality available with the MLR handle system. The LED integrated into the visualization unit signals alarm and authorization notification at the enclosure or cabinet. This allows users on-site to receive the same status information displayed by the Administration Suite software.
The LEDs positioned above and below the handle are illuminated and consume only minimal power. This enables the status of the handle to be clearly seen even from a distance.
The upper LED indicates the current status of the handle such as Ready for operation or “Access not authorized”. The lower LED indicates whether the environment of the handle is within a customer defined temperature range.
This allows deviations to be quickly identified on-site so that appropriate corrective measures can be taken.
The MLU handle system can be easily and conveniently managed using the Administration Suite software. This ensures reliable access control to server cabinets/enclosures and provides consistent documentation of all access events.
The MLU locks can be easily integrated into an existing security management system. The user is informed of the security status of the enclosure at all times.
Highly secure, multi-level locking systems can be implemented by installing more than one MLU lock on an enclosure. MLU locks and visualization units can be installed into existing cabinets/enclosures regardless of the opening size and clearances.
by DIRAK
28 E-LINE by DIRAK | Catalog 2012
MLU1000: Mechatronic Lock for Universal Applications
The compact design and small footprint of the MLU1000 makes it suitable for many different applications, particularly where space is limited. Since it is installed inside the enclosure, it cannot be seen from the outside and thus does not provide a point of attack for attempted access by unauthorized persons. The compact size of the MLU1000 enables it to be installed in just about any size drawer, cabinet or enclosure. Highly secure multi-level locking systems can be implemented by installing more than one MLU1000 on an enclosure.
The MLU1000 can be easily integrated into an existing security system by simply connecting it directly to the system. It makes no difference whether the system is an access control system using Administration Suite software (in progress) or a 3rd-party system.
The MLU1000 integrated status reporting function (open/closed) makes it easy for a management system to log and analyze access data. The user is always informed as to the status of the enclosure’s security.
Height: 21 mm
Length: 125 mm
Width: 29 mm
MLU1000 Technical Specifications
Material Die-cast zinc
Color Chrome matte
Control cable length 4 m
Supply voltage, current 24 V DC ± 10%, 100 mA
Status Proximity switch
Wall/sheet metal thickness independend
Opened electronically by Interrupting power (e.g., from a management system)
E-LINE by DIRAK | Katalog 2011 29
MLU1000 Lock stud
MLU1000 Lock
Frame or cabinet fixtureDoor or drawer
View from back/inside in open position
View from front/outside in open position
View from front/outside in closed position
Installation of the MLU1000
The MLU1000 is attached at the door frame or within the enclosure. The locking device is attached to the moving part of the enclosure (the door or drawer).
The lock stud must be properly aligned with the corresponding opening in the MLU1000 for secure locking.
Easy to integrate, the MLU1000 can be connected to any existing management system for lock monitoring and control. Simply connect the plus and minus wires of the MLU1000 electronic opening function to the appropriate terminals of the management system’s control module.
The status of the MLU1000 (open/closed) is reported to the management system, and can be used for analysis. Although most management systems usually indicate only whether the enclosure door is “open” or “closed,” the MLU allows for additional analysis. The additional data available for analysis allows breeches of security to be more quickly identified.
Wiring the MLU1000Control cable of the MLU
+-
Existing Management System
electronic opening of the MLU1000
gree
n, s
tatu
s co
ntac
t
brow
n, s
olen
oid
(-)
whi
te, s
olen
oid
(+)
yello
w, s
tatu
s co
ntac
t
Part number Description
600-9708.00-00000 MLU1000
by DIRAK
30 E-LINE by DIRAK | Catalog 2012
MLU1001: An Enhancement for Mechanical Latching Solutions
The MLU 1001 is the flexible alternative to mechanical latching solutions for a wide variety of enclosures and applications.
The MLU1001 system can be integrated into an existing management system.
With the use of a (control) motor, the MLU1001 is highly reliable, has a long life expectancy and can hold up against extreme force.
The lock operates easily and smoothly, even with a strong force (up to 100 Newtons) pushing against the inside of the door.
In the locked position, the MLU1001 will stay closed and stable against a tensile force up to 2,800 Newtons.
Technical Data MLU 1001
Power Supply 12 V, 0,5 A, 1sec Impuls
Maximum axial load 2500 N
Ready to open at up to 100 N
Closing cycles min 50.000
Housing ABS
Panel thickness Any
Electronic opening by interrupting the power circuit
20,5 mm
68 mm
45,1 mm5 mm
5 m
m46
,4 m
m
61 m
m
9,3
mm
E-LINE by DIRAK | Catalog 2012 31
MLU1001: An Enhancement for Mechanical Latching Solutions
Part No. Description
600-9003.00-00000 MLU1001
Installation of the MLU1001
The MLU1001 is attached at the door frame or within the enclosure. The locking device is attached to the moving part of the enclosure (the door or drawer).
The lock stud must be properly aligned with the corresponding opening in the MLU1001 for secure locking.
MLU1001 Lock
MLU1001 Lock stud
Frame or cabinet fixture
Door or drawer
View from back/inside in open position View from front/outside in open position View from front/outside in closed position
by DIRAK
32 E-LINE by DIRAK | Catalog 2012
System Overview MLU
MLU1000 MLU1001 MLU3000 MLU5000
The MLU1000 features a hardware interface enabling it to be integrated into an existing facility management system. When the power to the MLU1000 is interrupted, the electromechanic lock is opened.
The MLU1000 features a hardware interface enabling it to be integrated into an existing facility management system. When power is supported to the MLU1000 electromechanic lock is opened.
The MLU3000 is especially well suited for rooms in which a large number of cabinets/drawer are installed With just one IP address, up to 32 elektromechanical locks can be managed individually via an E-LINE by DIRAK Gateway.
The MLU5000 was developed to monitor and manage cabinets or drawers from a central location. This is made possible by assigning each electromechanical lock its own unique IP address.
Is customer-provided 3rd-party software needed?
depends on customer’s software /Management System
depends on customer’s software /Management System
No No
Administration Suite
No No Yes Yes
Emergency power?
No No Yes Yes
Authorization method
depends on customer’s software/ Management System
Transponder card Transponder card
IP addressable?
No No No Yes
Events logged?
The lock forwarded it’s status open/close. This status could used for events. Depends on customers
software/Management System
The lock forwarded it’s status open/close. This status could used for events. Depends on customers
software/Management System
Yes(in combination with Administration Suite)
Yes(in combination with Administration Suite)
User profiles
depends on customer’s software/Management System
depends on customer’s software/Management System
Yes(in combination with Administration Suite)
Yes(in combination with Administration Suite)
Four-Eyes” principle
depends on customer’s Management System
depends on customer’s Management System
Yes(in combination with Administration Suite)
Yes(in combination with Administration Suite)
Stand-alone option
depends on customer’s Management System
depends on customer’s Management System
Yes(in combination with Administration Suite)
Yes(in combination with Administration Suite)
Force against electronic lock
Locking bolt closed. Push against lock to open
The locking bolt comes off Locking bolt closed. Push against lock to open
Locking bolt closed. Push against lock to open
E-LINE by DIRAK | Catalog 2012 33
Operational Status Indication (MLU3000 und MLU5000)
Key Questions for Product Selection
blue steady: Handle ready for
operation
blue steady: Handle ready for
operation
green flashing: “Green Period” (free access w/o media)
red flashing: Alarm
green steady: Access authorized
orange steady: Handle opened
red steady: Access not authorized
red steady: Access not authorized
green steady: Temperature OK
red flashing: Temperature alarm
red flashing: Temperature alarm
green steady: Temperature OK
green steady: Temperature OK
green steady: Temperature OK
green steady: Temperature OK
green steady: Temperature OK
Do you want to use software for administration of your access control system, or do you prefer electronic verification without software (stand-alone)?
Are your enclosures located in different rooms, floors and/or buildings?
The optimal solution for you depends on your exact requirements. By combining various E-LINE by DIRAK solutions, you can achieve the optimal security system for your infrastructure.
with software
without software
MLU3000
MLU3000 MLU5000
no yes
by DIRAK
34 E-LINE by DIRAK | Catalog 2012
MLU3000: Locking solution for centralized server cabinet enclosures housing various cabinet types.
The MLU3000 is DIRAK’s locking solution for a wide variety of enclosures, server cabinets and doors from various manufacturers. These locks are based on the RS485-BUS system. They are ideal for electronically expanding and managing an existing mechanical locking system wherever the MLR3000 cannot be used.
MLU3000 locks can secure a wide variety of server cabinets and enclosures as well as doors, safety cabinets and individual drawers. Existing mechanical components are combined with the MLU1000 which is installed on the inside of the cabinet and the status display, MLU3000, which is visible from the outside. Enclosures equipped with the MLU3000 can be monitored by Administration Suite software or can be operated in stand-alone mode.
MLU3000 Technical Specifications
Three-part hardware system MLU3000 Set Set consists of: external MLU Reader; Network Reader Unit and MLU1000 Lock
Indicators on MLU Reader 2 x multicolor status LEDs and 1x backlit information field
Antenna For 125 kHz transponder (HID 26-bit system)
MLU1000 Lock
Material Die-cast zinc
Color Chrome matte
Control cable length 4 m
Supply voltage, current 24 V DC +/- 10 % 100 mA
Status contact Proximity switch
Thickness of mounting wall/sheet metal No restrictions
Opened electronically by: Interrupting power
MLU3000 Network Reader
Housing Reader unit in plastic housing, mountable with screws or self-adhesive pad
Nominal input voltage 12/24/48 V ± 10% (DC); depends on connected electr. lock
Standby current (system ready) 40 mA (DC)
Maximum current on RJ12 (LOCK) 1,5 A (DC)
Maximum current on relay terminals 3.0 A (DC), terminals 10-11
RS-232 interface RS-232 lines (RXD ,TXD, GND, Reader present, PC present), 38,400 Baud
Connection cable (Reader -> external MLU antenna)
8-pin; 350 cm; UL-approved, 26 AWG stranded wire; RJ45 connector molded onto one end; crimped JST ZHR-8 connector on other end
Relay output (screw terminals) 2,5 mm², screw on insertion side; Relay contact: 12 V, 3 A, 60 W, 120 VA, terminals 3-5
Door contact input (screw terminals) 2.5 mm², screw on insertion side, terminals 1 and 2
RS-485 interface RS-485 lines from E-LINE by DIRAK Gateway (+/A, -/B), 38,400 Baud
Open or closed when power interrupted This is configured in the Administration Suite Config-Tool depending on connected electr. lock
Storage capacity for transponder cards 2,000 cards + 1 master transponder
Storage capacity for events 500 events (ring buffer)
Storage capacity for time profiles 30 profiles
Integrated real-time clock With buffering for up to 60 min. at 25°C
Temperature range -20°C ... +70°C
E-LINE by DIRAK | Catalog 2012 35
The MLU3000 is especially well suited for use in rooms containing a large number of cabinets and doors that cannot be secured with the mechatronic locks for racks (MLR) due to incompatible latching mechanisms. The E-LINE-by-DIRAK-Gateway is the interface between the RS485 BUS and the Ethernet/LAN. A single gateway can support up to 32 MLU3000 locks using one shared IP address.
Connecting the MLU3000 with the Administration Suite software enables convenient and reliable access control. Security personnel can easily monitor and control all access.
The LEDs integrated into the MLU3000 housing display instantaneous alarm messages, authorizations and temperature statuses. Technicians on-site see the same information as shown in the Administration Suite software in the control center. A backlit field integrated into the housing can display customer specific information.
The MLU3000 and MLU5000 locks can be combined with each other as well as with our mechatronic locks for racks, MLR3000 and MLR5000. This provides the ability to collectively monitor both local and/or off-site cabinets and enclosures.
With MLR3000 locks, cabinets in datacenters can be secured even where it may not be possible to use the MLR series with modifications for 2 or 3 point cam, rod-latch or offset. The MLU3000 can be used as an additional latch for very high doors by installing an additional MLU1000 to the card reader.
An emergency power option is available with the Battery Pack accessory, which allows the MLU3000 to be opened in the event of a power failure.
MLU3000 locks are supplied as a set which includes the MLU1000, MLU Reader and Network Reader Unit.
1 2 3 4 5 6 7 9 10118
1 GND 2 Binary input (door contact) 3 Normally-open (NO) contact of the relay 4 Normally-closed (NC) contact of the relay 5 Common contact of the relay 6 unused 7 unused 8 Status contact of the MLU1000 9 Status contact of the MLU1000 10 Solenoid of the MLU1000 (+) 11 Solenoid of the MLU1000 (-)
Relay terminalThe MLU offers various configuration alternatives. By connecting the appropriate equipment, the full range of functions can be utilized.
by DIRAK
36 E-LINE by DIRAK | Catalog 2012
Wiring the MLU3000
Communication to the MLU3000 is handled via the E-LINE by DIRAK Gateway. The gateway unit is the interface between the RS485-BUS and the Ethernet/LAN and transmits and converts the information to the RS485 BUS. The junction boxes provide the breakout for an additional MLU3000 reader unit. One gateway can support up to 32 MLU3000 / MLU1000 pairs.
Utilizing the E-LINE by DIRAK MLU3000 series with the Administration Suite software provides a convenient and reliable access control solution for data racks or server cabinets. Security personnel can monitor and control all access from the convenience of their PCs.
MLR3000 GATEWAY
LAN OUTPUT CONFIG
MLU3000 READER
CX
VDC
LOCKCONFIG
ANTENNA
Node Point
INPUT MODUL OUTPUT
Power Supply
Power Supply
CN cabelCAT5 cabel
SWITCH/ETHERNET NETZWERK
CAT5 cabel
CN cabel CN cabel
Administration Suite
1 2 3 4 5 6 7 9 10118
MLU3000 READER
CX
VDC
LOCKCONFIG
ANTENNA
Node Point
INPUT MODUL OUTPUT
CN cabel
Control cabel
CN cabel
green, status contact
brown, solenoid (-)
Door contact
white, solenoid (+)
yellow, status contact
1 2 3 4 5 6 7 9 10118
Contol cable
green, status contact
brown, solenoid (-)
Door contact
white, solenoid (+)
yellow, status contact
...
Power Supply
Part number Description
610-9750.00-00000 MLU3000-Kit
E-LINE by DIRAK | Catalog 2012 37
MLU5000: Locking solution for decentralized server cabinet enclosures housing various cabinet types.
The MLU5000 locks are DIRAK’s solution for universal, decentralized use for server and data cabinets and can also be used for doors or individual drawers. Every MLU5000 has its own IP address, which allows current mechanical systems to be upgraded and administered
electronically even when enclosures are widely separated or in multiple locations. This system provides solutions where the MLR5000 does not fit into existing configurations.
MLU5000 Technical Specifications
Three-part hardware system MLU5000 Set Set consists of: external MLU Reader; Network Reader Unit and MLU1000 Lock
Indicators on MLU Reader 2 x multicolor status LEDs and 1x backlit information field
Antenna For 125 kHz transponder (HID 26-bit system)
MLU1000 Lock
Material Die-cast zinc
Color Chrome matte
Control cable length 4 m
Supply voltage, current 24 V DC +/- 10 % 100 mA
Status contact Proximity switch
Thickness of mounting wall/sheet metal No restrictions
Opened electronically by: Interrupting power
MLU5000 Network Reader
Housing Reader unit in plastic housing, mountable with screws or self-adhesive pad
Nominal input voltage 12/24/48 V ± 10% (DC); depends on connected electr. lock
Standby current (system ready) 40 mA (DC)
Maximum current on RJ12 (LOCK) 1,5 A (DC)
Maximum current on relay terminals 3.0 A (DC), terminals 10-11
RS-232 interface RS-232 lines (RXD ,TXD, GND, Reader present, PC present), 38,400 Baud
Connection cable (Reader -> external MLU antenna)
8-pin; 350 cm; UL-approved, 26 AWG stranded wire; RJ45 connector molded onto one end; crimped JST ZHR-8 connector on other end
Relay output (screw terminals) 2,5 mm², screw on insertion side; Relay contact: 12 V, 3 A, 60 W, 120 VA, terminals 3-5
Door contact input (screw terminals) 2.5 mm², screw on insertion side, terminals 1 and 2
TCP/IP interface Ethernet, 10100 autosense, up to 100 Mbit/s
Open or closed when power interrupted This is configured in the Administration Suite Config-Tool depending on connected electr. lock
Storage capacity for transponder cards 2,000 cards + 1 master transponder
Storage capacity for events 500 events (ring buffer)
Storage capacity for time profiles 30 profiles
Integrated real-time clock With buffering for up to 60 min. at 25°C
Temperature range -20°C ... +70°C
by DIRAK
38 E-LINE by DIRAK | Catalog 2012
Each MLU5000 has its own individual IP address and can secure every server cabinet, enclosure and door even when distributed over various buildings and floors. Every MLU5000 can be directly connected to the Ethernet/LAN via the MLU5000 reader, which eliminates the need for a separate BUS system.
The MLU5000 complements an existing mechanical system by combining the MLU1000, which is installed on the inside of the cabinet, with the MLU5000 access indicator which is visible from the outside. Enclosures equipped with the MLU5000 can be conveniently managed and controlled by Administration Suite software, or can be operated in stand-alone mode.
Connecting the MLU5000 with the Administration Suite software enables convenient and reliable access control. Security personnel can easily monitor and control all access.
The LEDs integrated into the MLU5000 housing display instantaneous alarm messages, authorizations and temperature statuses. Technicians on-site see the same information as is shown in the Administration Suite software in the control center. A backlit field integrated into the housing can display customer specific information.
The MLU5000 and MLU3000 locks can be combined with each other as well as with our mechatronic locks for racks, MLR5000 and MLR3000. This provides the ability to collectively monitor both local and/or off-site cabinets and enclosures.
With MLR5000 locks, decentralized data cabinets can be secured even where it may not be possible to use the MLR series with modifications for 2 or 3 point cam, rod-latch or offset.
The MLU5000 can be used as an additional latch for very high doors by installing an additional MLU1000 to the card reader.
An emergency power option is available with the Battery Pack accessory, which allows the MLU5000 to be opened in the event of a power failure.
MLU5000 locks are supplied as a set which includes the MLU1000, MLU Reader and Network Reader Unit.
1 2 3 4 5 6 7 9 10118
1 GND 2 Binary input (door contact) 3 Normally-open (NO) contact of the relay 4 Normally-closed (NC) contact of the relay 5 Common contact of the relay 6 unused 7 unused 8 Status contact of the MLU1000 9 Status contact of the MLU1000 10 Solenoid of the MLU1000 (+) 11 Solenoid of the MLU1000 (-)
Relay terminalThe MLU5000 offers various configuration alternatives. By connecting the appropriate equipment, the full range of functions can be utilized.
E-LINE by DIRAK | Catalog 2012 39
Communication to the MLU5000 occurs via the TCP/IP-protocol. Every reader is given a static IP address and is available within the network at any time. Therefore, the MLR5000 requires no separate BUS system as the existing Ethernet/LAN is used instead. Installation is simple and quick.
Combining the E-LINE by DIRAK MLU5000 series with the Administration Suite software provides a convenient and reliable access control solution for data racks or server cabinets. Security personnel can monitor and control all access from the convenience of their PCs.
Wiring the MLU5000
Part No. Description
610-9650.00-00000 MLU5000-Kit
MLU5000 READER
LAN
VDC
LOCKCONFIG
ANTENNAPower supply
Control cable
green, status contact
brown, solenoid (-)
Door sensor
white, solenoid (+)
yellow, status contact
1 2 3 4 5 6 7 9 10118
MLU5000 READER
LAN
VDC
LOCKCONFIG
ANTENNAPower supply
Control cable
green, status contact
brown, solenoid (-)
Door sensor
white, solenoid (+)
yellow, status contact
1 2 3 4 5 6 7 9 10118
CAT5/6 Cabel CAT5/6 Cable
Administration Suite
SWITCH/ETHERNET NETWORK
SWITCH/ETHERNET NETWORK
...
by DIRAK
40 E-LINE by DIRAK | Catalog 2012
MLA – Mechatronic Lock Accessories
DIRAK offers a variety of accessories for its MLR-locking systems
E-LINE by DIRAK | Catalog 2012 41
DesktopReader
Administration SuiteWith our software you have full control and administration of the E-LINE by DIRAK MLR3000 and MLR5000 systems. For details on the Administration Suite, please turn to page 22.
Part Number
608-6801.00-00000
The E-LINE by DIRAK Desktop Reader displays the transponder codes of your access media at your desk, and transmits them directly into the Administration Suite to configure user access. The Desktop Reader is housed in a compact enclosure and includes a USB 2.0 cable.
Part Number
608-9842.00-00000
When you connect the E-LINE by DIRAK Door Contact to the Readers of the MLR3000 and MLR5000 Systems, our Administration Suite software will display the current status of the cabinet door.
Door ContactPart Number
607-5959.00-00400
Country-specific versions of the E-LINE by DIRAK power supplies are available for the EU, USA, AUS, UK, and JP.12 V, 0,75 A
Power Supplies
Part Number
EU 607-5905.00-00000
UK 607-5916.00-00000
EU power supply, 24V Output 1.0 A (Input: 100-240V)
Power Supply 24V Part No.
607-5968.00-00000
by DIRAK
42 E-LINE by DIRAK | Catalog 2012
Additional components for the installation of the handle system can be found in the DIRAK standard product offerings (round and flat rods, cams, etc.). A general catalog is available upon request. Specialists are available for additional questions. Contact information can be found in the back of this catalog. .
Lock Components
Part No.
910-0101.01-00000 Full Catalog
With the adjustable torque of 0.3 - 1.2 Nm mechatronic systems can be installed with the recommended torque.
Torque screwdriver by WERA Part No.
608-9842.00-00000
Included: 1 Torque screwdriver Hardcover Box, 1 Phillips Bit PH1, 1 Phillips Bit PH2
In the event of a power outage the Battery Pack will allow an emergency opening procedure for the MLR3000, MLR5000, MLU3000 and MLU5000. There will be no interruption of event logging and no security vulnerabilities. The Battery Pack is connected to the gateway of the MLR handle or to the antenna unit of the MLU.
Battery Pack Part No.
610-9901.00-00001
The E-LINE by DIRAK Mounting Kit contains a mounting plate on which additional units, such as Reader, Gateway and Node Point, can be mounted.
Mounting KitPart Number
608-5926.00-00000
E-LINE by DIRAK | Catalog 2012 43
by DIRAK
Transponder Cards with Your Corporate Design
Your corporate design can be incorporated on your transponder card.
In addition to including a photo and name on the ID cards, they can be customized to included your corporate design or logo.
Transponder cards are just as valuable as credit cards. If they display your corporate design, your visibility grows. We can print your transponder cards in your corporate colors using your print template for text and images. The results are virtually identical to offset printing.
by DIRAK
44 E-LINE by DIRAK | Catalog 2012
To customize your transponder cards, we need a print-ready file with your desired design – or we can work with you to create your design. If submitting your own design, please follow the following specifications:
•Size: 3” Wide X 2” High. •Resolution: 300 dpi. • Image: High resolution PDF file.
Send us your finished image or a high resolution PDF file.
If you need help creating your design, send us the elements you would like to have on the card, such as your logo, images, text, etc., and we will work with you to produce a custom card.
Transponder Card Print Template
Technical Specifications
Printing technique HDP dye sublimation/ resin thermal transfer
Resolution 300 dpi (11.8 dots/mm)
Colors Up to 16.7 million/256 shades per pixel
Print area Marginless
Optional added security feature Protective holographic lamination is available on request. All attempts to separate individual layers will result in destruction of the printed image.
Part Number Description
607-5926.00-XXXXX Custom printing on our transponder cards to your specifications
E-LINE by DIRAK | Catalog 2012 45
MLE – Mechatronic Lock for Enclosures
The E-LINE by DIRAK MLE Series (Mechatronic Lock for Enclosures) offers the ability to lock enclosures in outdoor areas mechatronically and monitor them from a central location. The swinghandles feature enhanced protection against vandalism, and are ideal for use in publicly accessible areas such as airports, train stations or problem neighborhoods.
Enclosures in outdoor and publicly accessible areas. Outdoor enclosures that are freely accessible are increasingly requiring enhanced protection against vandalism, theft of materials and failure of the technical infrastructure.
All swinghandles of the MLE Series are designed and constructed to provide enhanced protection against vandalism and forced entry. They are used in outdoor and publicly accessible areas, where there is little or no surveillance or are isolated from the control center, which makes them inherently subject to high risk of forced entry or vandalism.
The MLE Systems are differentiated between “OR” and “AND” logic for opening the handles.
Technical Specifications
“OR” Opening: The handle can be opened either when authorization is given electronically by your management system, or when a mechanical key is used on site.
“AND” Opening: In this case, opening is only possible when the management system gives authorization electronically and at the same time, a mechanical key is used on site.
MLE1100 MLE2100 MLE1200 MLE2200
“OR” opening yes no yes no
“AND” opening no yes no yes
Dual cylinder version no no yes yes
To open electronically, the management system must … Apply power Interrupt power Apply power Interrupt power
Open/closed status reported yes yes yes yes
Supply voltage/current 48V DC, 120 mA 24V DC, 100 mA 48V DC, 120 mA 24V DC, 100 mA
Tested analogous to DIN V ENV 1627* yes yes yes yes
by DIRAK
46 E-LINE by DIRAK | Catalog 2012
In some cases, two different companies may share an enclosure. Due to mechanical key locking and existing company-wide key coding, each company may require their own keys and profile cylinders. The mechatronic MLE Swinghandles for use in outdoor areas are available as both single and dual cylinder versions in each of the two logic modes (“OR” / “AND”).
One or Two Profile Cylinders: The choice is yours
System Overview
Which opening logic do you prefer?
MLE1100 MLE1200 MLE2100 MLE2200
Do you need one or two lock cylinders?
Do you need one or two lock cylinders?
OR AND
1 12 2
E-LINE by DIRAK | Catalog 2012 47
MLE1100: “OR” Opening with One Profile Cylinder
E-LINE by DIRAK makes it possible to lock outdoor enclosures mechatronically. The swinghandles are well suited for protection against vandalism in outdoor areas that are easily accessible but not under constant surveillance where such protection is often needed.
Special Feature of the MLE1100: It can be opened either mechanically with a key or after electronic authorization by an administration system.
The MLE1100 is commonly used in public areas and facilities such as airports and train stations. Reliable and secure solutions are needed to lock such enclosures. The mechatronic locks can be easily integrated into existing management systems.
Enclosures and cabinets in outdoor or publicly accessible areas are often subjected to adverse conditions. Changing weather conditions and vandalism are the prime factors that must be taken into account. The tight gap between the handle and its housing prevents tools from being inserted underneath the handle. Special reinforcement around the handle provides additional protection against attempts to pry it open.
MLE1100 Technical Specifications
Material Die-cast zinc
Color Black RAL 9005 (other colors available on request)
Indicator LED
Opening logic “OR”
Supply voltage, current 48 V DC ± 10%, 120 mA
Status Proximity switch (dry contacts)
Sheet metal panel thickness 2 mm (other size on request)
Opened electronically by: Applying power (e.g., from a management system)
Profile cylinders 1
Water- and dust-tight according to IP65/67 / DIN EN 60529
“OR” OpeningIn order to open the swinghandle, either power must be supplied to the handle, or the profile cylinder lock unlocked by hand with a key. Power can be applied from an existing management system, for example, after access authorization has been verified. An LED on the swinghandle indicates “ready to be opened,” and the handle must then be opened within 40 seconds of applying power.
by DIRAK
48 E-LINE by DIRAK | Catalog 2012
The MLE1100 can be very easily integrated into an existing management system. Connect the plus and minus wires of the swinghandle’s electronic opening function to the appropriate terminals of the control module of your authorization or monitoring system.
The status of the handle’s position (open /closed) is reported to the management system, and can be used for analysis. Although most management systems usually show only whether the enclosure door is “open” or “closed,” the MLE1100 provides additional data. This data can be easily and quickly analyzed to identify a possible security breech.
Part number Description
600-9003.00-00000 MLE1100
Wiring the MLE1100
Control cable of the MLE1100
+-
Existing Management System
electronic opening of the MLU1000
gree
n, s
tatu
s co
ntac
t
brow
n, s
olen
oid
(-)
whi
te, s
olen
oid
(+)
yello
w, s
tatu
s co
ntac
t
20,1
+0,1 m
m
46 m
m
22.5 +0,5 mm
46 mm
Panel cutout including paint
Door center
105
mmLenght:
166 mm
Width: 53 mm
Height: 31 mm
E-LINE by DIRAK | Catalog 2012 49
MLE2100: “AND” Opening with One Profile Cylinder
The MLE2100 is recommended when an enhanced security level is needed.
The MLE2100 Series handles can only be opened using “AND” logic. That is, both a manual key and electronic authorization by a management system are required at the same time. This provides additional security for the enclosure. The MLE2100 can be easily integrated into your existing management system.
Particularly in outdoor or publicly accessible areas, special protection is needed against vandalism and changing weather conditions. These industrial enclosures are often located at curbside in cities or in publicly accessible buildings. It is imperative that they be locked and controlled with the best possible security.
Enclosures in outdoor and public areas must be protected against a variety of challenges and hazards including changing weather conditions and vandalism. E-LINE by DIRAK products provide high-tech solutions for additional security.
The tight gap between the handle and its housing prevents tools from being inserted underneath the handle. Special reinforcement around the handle provides additional protection against attempts to pry it open.
MLE2100 Technical Specifications
Material Die-cast zinc
Color Black RAL 9005 (other colors available on request)
Opening logic “AND”
Supply voltage, current 24 V DC ± 10%, 100 mA
Status Inductive sensor (10...30 V DC, ≤ 15 mA)
Sheet metal panel thickness 2 mm (other size on request)
Opened electronically by: Interrupting power (e.g., from a management system)
Profile cylinders 1
Water- and dust-tight according to IP65/67 / DIN EN 60529
“AND” OpeningIn order to open the swinghandle, power to the handle must be interrupted at the same time the cylinder lock is opened on site with a key. Power is interrupted by a management system after authorization has been verified. The current “open/closed” status is transmitted to the management system where it can be further processed and logged in for tracking purposes. This higher security level does not allow the handle to be opened mechanically. As long as power is still supplied to the handle, the handle remains locked.
by DIRAK
50 E-LINE by DIRAK | Catalog 2012
It is easy to integrate the MLE2100 into an existing management system. Simply connect the plus and minus wires of the swinghandle’s electronic opening function to the appropriate terminals of the control module of the authorization or monitoring system.
The position of the handle (open or closed) is transmitted as status data to the management system, thus allowing analysis of this data. The MLE2100 extends the status control provided by conventional management systems, as they show only whether the enclosure door is open or closed. Possible breeches or even sabotage can be more quickly identified with the MLE2100.
Part number Description
600-9001.00-00000 MLE2100
Wiring the MLE2100Control cable
of the MLE2100
+-
Existing ManagementSystem
gree
n, G
ND
(-)
brow
n, G
ND
(-)
yello
w, s
olen
oid
(+)
whi
te, s
enso
r (+)
rose
, sen
sor c
onta
ct
grey
, not
use
d
Electronic opening ofthe swinghandle
20,1
+0,1 m
m
46 m
m
22.5 +0,5 mm
46 mm
Panel cutout including paint
Door center
105
mmLenght:
166 mm
Width: 53 mm
Height: 31 mm
E-LINE by DIRAK | Catalog 2012 51
MLE1200: “OR” Opening with Dual Profile Cylinders
With the MLE1200, two organizations with different keys or key coding systems can open the enclosure according to “OR” logic. Access is gained either mechanically by key or from a management system after authorization has been verified. This makes the handle, which can be easily integrated into existing management systems, particularly well suited for enclosures that are shared by different organizations.
Enclosures in outdoor or public areas must be protected against a variety of challenges and hazards including vandalism and weather conditions. Secure and controlled locking of these enclosures is of utmost importance. E-LINE by DIRAK products feature locking technologies that make attempts at forced entry more difficult.
MLE1200 Technical Specifications
Material Die-cast zinc
Color Black RAL 9005 (other colors available on request)
Opening logic “OR”
Supply voltage, current 48 V DC ± 10%, 120 mA
Status Proximity switch (dry contacts)
Sheet metal panel thickness 2 mm (other size on request)
Opened electronically by: Applying power (e.g., from a management system)
Profile cylinders 2
Water- and dust-tight according to IP65/67 / DIN EN 60529
“OR” OpeningIn order to open the swinghandle, power must be supplied to the handle – or the profile cylinder lock can be unlocked using a key. Power can be applied from an existing management system after access authorization has been verified. The handle must then be opened within 40 seconds of supplying power.
by DIRAK
52 E-LINE by DIRAK | Catalog 2012
The MLE1200 is easily integrated and can be connected to any existing management system for lock monitoring and control. Simply connect the plus and minus wires of the swinghandle’s electronic opening function to the appropriate terminals of the management system’s control module.
The status of the handle’s position (open / closed) is reported to the management system, and can be used for analysis. Although most management systems usually show only whether the enclosure door is “open” or “closed,” the MLE1200 provides additional data. This data can be easily and quickly analyzed to identify a possible security breech.
Part number Description
600-9004.00-00000 MLE1200
Wiring the MLE1200Control cable
of the MLE1200
+-
Existing Management System
electronic opening of the MLU1000
gree
n, s
tatu
s co
ntac
t
brow
n, s
olen
oid
(-)
whi
te, s
olen
oid
(+)
yello
w, s
tatu
s co
ntac
t
20,1
+0,1 m
m
46 m
m
22.5 +0,5 mm
46 mm
Panel cutout including paint
Door center
105
mm
Length: 166 mm
Width: 53 mm
Height: 31 mm
E-LINE by DIRAK | Catalog 2012 53
MLE2200: “AND” Opening with Dual Profile Cylinders
When a greater level of security is required, the MLE2200 is the standard solution and is recommended for use in public areas where enhanced protection is needed against vandalism and break-ins.
When several organizations share an enclosure and greater security is required, the MLE2200 handles are designed to operate according to “AND” logic. This requires that both an on-site key and an authorization signal are needed at the same time to open the handle. The dual cylinder design of the handles enables
them to be opened by two different organizations with different keys or key coding systems. Like the other members of the MLE Series, the MLE2200 is easily integrated into existing management systems.
Enclosures in outdoor or publicly accessible areas are often subjected to adverse conditions. Changing weather conditions and vandalism are the prime factors that must be considered. The secure design of the MLE Series prevents tools from being inserted underneath the handle. Reinforcement around the handle provides additional protection against forced attempts to pry it open.
MLE2200 Technical Specifications
Material Die-cast zinc
Color Black RAL 9005 (other colors available on request)
Opening logic “AND”
Supply voltage, current 24 V DC ± 10%, 100 mA
Status Inductive sensor (10...30 V DC, ≤ 15 mA)
Sheet metal panel thickness 2 mm (other size on request)
Opened electronically by: Interrupting power (e.g., from a management system)
Profile cylinders 2
Water- and dust-tight according to IP65/67 / DIN EN 60529
“AND” OpeningIn order to open the swinghandle, power to the handle must be interrupted and at the same time, the cylinder lock must be opened on site with a key. Power is interrupted by an existing management system after authorization has been verified. The “open/closed” status is transmitted to the management system where it can be further analyzed for tracking purposes. With this level of security, the handle can not be opened mechanically unless power to the handle has been interrupted. As long as power is still being supplied to the handle, the handle remains locked.
by DIRAK
54 E-LINE by DIRAK | Catalog 2012
The MLE2200 can be easily integrated into an existing management system for lock monitoring and control. Simply connect the plus and minus wires of the swinghandle’s electronic opening function to the appropriate terminals of the management system’s control module.
The open/closed status of the handle’s position is reported to the management system and analyzed. Conventional management systems show only whether the enclosure door is open or closed, but the additional data provided by the MLE2200 handle allows a more precise analysis to be made. Possible breeches of security can be quickly identified. The system shows actual door handle status at all times.
Part number Description
600-9002.00-00000 MLE2200
Wiring the MLE2200
Control cable of the MLE2200
+-
Existing ManagementSystem
gree
n, G
ND
(-)
brow
n, G
ND
(-)
yello
w, s
olen
oid
(+)
whi
te, s
enso
r (+)
rose
, sen
sor c
onta
ct
grey
, not
use
d
Electronic opening ofthe swinghandle
20,1
+0,1 m
m
46 m
m
22.5 +0,5 mm
46 mm
Panel cutout including paint
Door center
105
mm
Length: 166 mm
Width: 53 mm
Height: 31 mm
E-LINE by DIRAK | Catalog 2012 55
Visit us online at www.elinebydirak.com to learn more about our E-LINE by DIRAK Series of mechatronic locks. You can use the online Configurator to find the locking solution best suited to your system. The Configurator provides a step-by-step guide to the locking system that is just right for your application.
The website describes all modules of the E-LINE by DIRAK Series in detail with data sheets, product comparisons, installation drawings and installation videos. Please visit our FAQ page to find the answers to frequently asked questions.
Subscribe to our e-mail Newsletter and always stay informed of the latest product news.
ELINEbyDIRAK.de: Homepage with Configurator and Installation Aids
DIRAK GmbH
Königsfelder Str. 1 58256 Ennepetal / Germany Phone +49 (0) 23 33 / 837-0 Fax +49 (0) 23 33 / 837-103 [email protected]
www.elinebydirak.de
DIRAK INC.
22560 Glenn Drive Sterling, VA 20164 Tel.: +1-703-378-7637 Fax: +1-703-378-7638 [email protected]
www.elinebydirak.com