16
29 ottobre 2007 Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection Tube Ciullo G.

29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

Embed Size (px)

Citation preview

Page 1: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Finned Tube to increase target density?

Openable cell for p↑p↑

Ideas to increase cell thickness

Test on the finned Injection Tube

Ciullo G.

Page 2: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

The openable cell

• Openable Cell to inject pbar @ AD

Y = 100, x = 50 mm

• Closed cell, square 10x10 mm,

5 m teflon foil.

Sampling tube

Injection Tube

Page 3: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Estimation of the target thickness• Thickness (tc) of the cell

• tc [atom/cm2]

• Cell Geometry: square 10x10 mm, length 400 mm

– IHERMES-ABS = 6.5 • 1016at/s then tc=8.81 • 1013at/cm2

• Some ideas “appear” in order to increase tc?!

2C

tot

LItc

TubeEstBRPABSLL CCCC .2/2/totC

cmin unit length

3.51sl

4.34

'-12

s

l

sl

AA

M

TC

3,94 3,94 5,83

04,181,41

32,11

1

1,04

Page 4: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Lower conductance thicker Target• Lowering the ABS injection Tube Temperature

Target thickness vs ABS injection tube temperature

6

7

8

9

10

11

12

25 50 75 100 125 150 175 200 225 250 275 300 325

ABS feeding tube Temperature [K]

Inte

gra

ted

tar

get

th

ickn

ess

[10

13 at

om

/cm

2 ]

20%

30%

10%

Page 5: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Lower conductance thicker Target• Longer ABS injection Tube

Target thickness vs ABS tube length

6

7

8

9

10

11

12

8 10 12 14 16 18 20 22

ABS feeding tube Length [cm]

Inte

gra

ted

tar

get

th

ickn

ess

[10

13 at

om

/cm

2 ]

10%

20%

Page 6: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Lower conductance thicker Target• ABS injection Tube with fins

cmin unit length

3.51sl

4.34

'-12

s

l

sl

AA

M

TC

Finned tube

8,00E+13

8,50E+13

9,00E+13

9,50E+13

1,00E+14

1,05E+14

1,10E+14

0 5 10 15

Number of fins

thic

kn

es

s (

at/

cm

q) 18 %

23 %AI 'Incoming atoms

Outcoming atoms

Page 7: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Finned tubes

Page 8: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Test on the finned tubes

Q = (Pcal-P cv) Ccal = (Pcv-P RF) Ccv

Page 9: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Measure of Ccal

• Misura di Ccal

• Evacuazione di Vcal da Ccal

. inoltre ;

cal

cal

cal

calcalcal V

V

C

CVC

0 20 40 60 80 1002

3

4

5

6

7

8

9

Data: aug17Cmeas_PbmModel: ExpDec1Equation: y = A1*exp(-x/t1) + y0Weighting: y Instrumental Chi^2/DoF = 0.09545R^2 = 1 y0 0.23024 ±0.01451A1 8.63199 ±0.01113t1 69.76054 ±0.24462P

bm (

mba

r)

time (min.)

Pbm ExpDec1 fit of aug17Cmeas_Pbm

Page 10: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Measured of Q calibrated

6,0x10-5 8,0x10-5 1,0x10-4 1,2x10-4 1,4x10-4 1,6x10-4 1,8x10-4 2,0x10-4

4,0x10-4

6,0x10-4

8,0x10-4

1,0x10-3

1,2x10-3

1,4x10-3

1,6x10-3

inear Regression for Qcalc0fins230_qCAL:Y = A + B * XWeight given by Qcalc0fins230_ErrQcal error bars.

Parameter Value Error------------------------------------------------------------A -7,2146E-5 1,96151E-6B 8,28848 0,01727------------------------------------------------------------

R SD N P------------------------------------------------------------0,9999 6,72786 3 0,00892------------------------------------------------------------

Qca

lib (

mb

ar

l/s)

Pcv

(mbar)

qCAL Linear Fit of Qcalc0fins230_qCAL

Calibrated througput measured with a 1% error

0 fins for 23 august

Q calibration curve derived for all finned tubes

Page 11: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Fixing in mind problems

• We can measure – The Qincoming is well

calibrated measurement

– Then derive the tc

• To derive the tc, from data

» We need Qincaming (2%)

And

» Coutcoming (30%)

Page 12: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

I measured and see MC simulation

0 2 4 6 8 10 126,5x10-4

7,0x10-4

7,5x10-4

8,0x10-4

8,5x10-4

9,0x10-4

9,5x10-4

1,0x10-3

1,1x10-3

1,1x10-3

Q a

tom

ic b

ea

m (

mb

ar

l/s)

Number of fins

Q atomic beam measuredQ normalized as A

0 and derived as Q~A

Page 13: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Surviving atomic beam

Page 14: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

s

l

A

A

sl

AA

M

TC

-1

0

2

13.51sl

4.34

'

Ccv measured and calculated

%]30 of [

%]2 of [

4.2 error

err

P

QC

cv

calmeas

Next step: use the baratron to measure PCV ?!

Page 15: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Thickenss of the cell

2C

tot

LItc

Page 16: 29 ottobre 2007Torporkov visit Finned Tube to increase target density? Openable cell for p p Ideas to increase cell thickness Test on the finned Injection

29 ottobre 2007 Torporkov visit

Conclusions

• To increase the target density– Lower temperature of ABS injection tube

– Mechanical complication and vibrations.

– Longer tube– Test on the recombination and transport required?

– Finned tube– Due to the azimuthal motion of the focused atomic beam

» Reduced target thickness.