TranzStor

1Xi

Doc# 27-0014UM Rev B Issued 07/05

2

FCC INFORMATION

CAUTIONRISK OF ELECTRIC SHOCK - DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK OF UNIT). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALI-FIED PERSONNEL.

This symbol warns the user that insulated voltage within the unit may have sufficient magnitude to cause electric shock. Therefore, it is dangerous to make any kind of contact with any part inside this unit.

This symbol alerts the user that important literature concerning the operation and maintenance of this unit has been included. Therefore it should be read carefully in order to avoid any problems.

REGULATORY

1. Use the power and video cables supplied with the product to help prevent interference with radio and televi-sion reception. The use of cables and adapters may cause interference with electronic equipment in the vicinity of this unit.

2. Changes or modifi-cations not expressly approved by Z Micro-systems could void user’s warranty.

TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESSALL THREE PRONGS CAN BE FULLY INSERTED.

TranzStor

1Xi

Doc# 27-0014UM Rev B Issued 07/05

3

SECTION PAGE

Introduction ....................................................................................................................4 About This Manual .........................................................................................4 Safety Precautions .........................................................................................4 Product Description ........................................................................................5Installation Instructions ...................................................................................................6 Shipment Contents .........................................................................................6 Required Tool .................................................................................................6 Preparations ...................................................................................................6 Front View IDE Option ...................................................................................7 Rear View IDE Backplane ..............................................................................7 Heater Option Reset Cable ............................................................................8 Master/Slave Jumper Settings (IDE) .............................................................9 Front View SCSI Option ................................................................................10 Rear View SCSI Backplane ..........................................................................10 Heater Option Reset Cable ...........................................................................11Operations ....................................................................................................................15 TP7 Overview ................................................................................................15 Removing the TP7 ........................................................................................15 Inserting the TP7 ...........................................................................................16 TranzStor 1Xi Status LEDs ...........................................................................16Replacements ..............................................................................................................17 Mechanical Outline for TranzStor 1Xi ..........................................................................18 Appendix ......................................................................................................................19 Specifications for TranzStor 1Xi ...................................................................19 Warranties ....................................................................................................20 Customer Support .........................................................................................26 Customer Feedback ......................................................................................27

TABLE OF CONTENTS

Doc# 27-0014UM Rev B Issued 07/05

4

ABOUT MANUAL

SAFETY PRECAUTIONS

DANGER: To avoid shock hazard:

Do not connect or disconnect the TranzStor 1Xi during an electrical storm. The power cord plug must be connected to a properly wired and grounded power outlet. Any equipment to which the TranzStor 1Xi will be attached must also be connected to properly wired and grounded power outlets.

INTRODUCTION

This Manual is also available on the Z Microsystems website (www.zmicro.com). We recommend you read this manual carefully and follow the instructions in the Installation chapter for verification of system functions and control settings.

Doc# 27-0014UM Rev B Issued 07/05

5

PRODUCT DESCRIPTION

INTRODUCTION

Platform independent data storage — the TranzStor 1Xi is a single bay docking station that runs in any computer and hosts a removable TranzPak 7 data storage module.

A TranzStor 1Xi installs into any standard 5.25” peripheral slot in any computer or work-station: at home, office, lab or in the field, and provides a field-ready platform to store and transport maximum data from one computer to another.

Stay with the same media — with a TranzStor 1Xi you no longer have to transport large data files using multiple disks. When you stay with the same media, there is less risk of creating errors. The TranzStor 1Xi allows you to take the whole hard drive with you — that means you can transport, plug in and run your most intensive software applications any-where.

Imagine the flexibility and efficiency that a quick-swap, high-end, platform independent transportable data storage system can bring.

Doc# 27-0014UM Rev B Issued 07/05

6

REQUIRED TOOLS

• None

NOTE: For the fastest and easiest installation of the TranzStor 1Xi, follow these steps in the sequence they are presented.

PREPARATIONSIn preparation to install the TranzStor 1Xi, take the following precautionary steps:

Do not connect or disconnect the unit dur-ing an electrical storm.

Any equipment to which the unit will be at-tached must also be connected to properly wired and grounded power outlets.

Ensure all of the following parts are in-cluded in the package received from Z Mi-crosystems. Verify all parts have not been damaged during shipment. If any of the parts are missing or damaged, immediately contact Z Microsystems Customer Service at 858-657-1000.

• The TranzStor 1Xi • User Manual • SCSI Terminator (SCSI option)• 4 mounting screws

Remember to save the unit’s original shipping materials. It may be necessary to move the unit at a later date.

SHIPMENT CONTENTS

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

7

FRONT VIEW IDE OPTIONSeveral cable connections between the TranzStor 1Xi and the host computer must be made before the unit can be used. The pictures below show the front and rear of a TranzStor 1Xi (IDE) and the connection points for these cable.

IDE Cable Connector

Power Cable Conector

Pin 1

Master/Slave con-figuration jumpers

Mounting inserts( 2 on each side )

Flip up door

REAR VIEW IDE BACKPLANE

IDE identification label - Green

Mating Connector Housing : AMP 1-480424-0 Mating Connector Socket Co-tacts : AMP 60619-4Pinout :1: +12VDC2: GND3: GND4: +5VDC

Power on light - GreenDrive activity light - Yellow(See pg 14 for LED Status Info)

J5

INSTALLATION

The TP7 is tested and qualified for operating temperature limits as low as -32˚ Celsius (with heater). A -32˚ C maximum requires a 35 minute warm up. The TP7 is qualified for -20˚ C for continuous operation.

Doc# 27-0014UM Rev B Issued 07/05

8

HEATER OPTION RESET CABLE

When a TP7 is configured with the heater option, the backplane will also have a reset cable on the bottom right corner. The following image calls out the location of the reset cable connector.

The reset cable connector is found in the same bottom right location in both IDE and SCSI configurations.

Reset Cable Connector

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

9

MASTER/SLAVE JUMPER SETTINGS (IDE)

Note: Some systems may require you to use the 15 head logical architecture. This is because they translate a drive greater than 4 GB by multiplying the head count by 16. The result (16 x 16 = 256) is interpreted as 0 heads with a 0 capacity and is an illegal head count. Selecting the 15 head logical jumpers produces a legal translation (16 x 15 = 240). The translated cylinder count varies to achieve the drive’s full capacity.

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

10

FRONT VIEW SCSI OPTIONSeveral cable connections between the TranzStor 1Xi and the host computer must be made before the unit can be used. The picture below shows the front and rear of a TranzStor 1Xi (SCSI) and the connection points for these cable.

SCSI Cable Connector

SCSI ID switch

Mounting inserts( 2 on each side )

Power on light - GreenDrive activity light - Yellow(See pg 14 for LED Status Info)

Flip up door

REAR VIEW SCSI BACKPLANE

SCSI identification label - Red

Power Cable Connector

Pin 1

Mating Connector Housing : AMP 1-480424-0 Mating Connector Socket Con-tacts : AMP 60619-4Pinout :1: +12VDC2: GND3: GND4: +5VDC

The TP7 is tested and qualified for operating temperature limits as low as -32˚ Celsius (with heater). A -32˚ C maximum requires a 35 minute warm up. The TP7 is qualified for -20˚ C for continuous operation.

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

11

HEATER OPTION RESET CABLE

When a TP7 is configured with the heater option, the backplane will also have a reset cable on the bottom right corner. The following image calls out the location of the reset cable connector.

The reset cable connector is found in the same bottom right location in both IDE and SCSI configurations.

Reset Cable Connector

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

12

When connecting the TranzStor 1Xi SCSI version into a computer system, several things must be considered. The SCSI cable that connects the system SCSI Host Bus Adapter (HBA) to the TranzStor 1Xi backplane must be a 68 pin cable that is rated for the SCSI specification that is to be supported by the HBA and the TP7 stor-age module. Generally this is Ultra 2, Ultra 160, Ultra 320, etc. See the table below for a summary of the various versions of the SCSI specification. The cable must have a male 68 pin high density D connector which mates with the SCSI connector on the TranzStor 1Xi SCSI backplane. Once the cable has been selected, a terminator must be installed at the end of the cable. The end of the cable may be just after the connection to the TranzStor 1Xi or the cable may daisy chain to other SCSI de-

Fig. 1 SCSI Terms & Terminology

SCSI-1(2) 5 8 6 (3) 25 8 Fast SCSI (2) 10 8 3 (3) 25 8 Fast Wide SCSI 20 16 3 (3) 25 16 Ultra SCSI (2) 20 8 1.5 (3) 25 8 Ultra SCSI (2) 20 8 3 - - 4 Wide Ultra SCSI 40 16 - (3) 25 16 Wide Ultra SCSI 40 16 1.5 - - 8 Wide Ultra SCSI 40 16 3 - - 4 Ultra2 SCSI (2,4) 40 8 (4) 12 25 8 Wide Ultra2 SCSI (4) 80 16 (4) 12 25 16 Ultra3 SCSI or Ultra160 SCSI (6) 160 16 (4) 12 (5) 16 Ultra320 SCSI (6) 320 16 (4) 12 (5) 16

SCSI Version

Bus Speed,

Max. Bus Lengths, Meters (1)

Max. Device Support

Bus Width, bits

Single-ended LVD HVD

vices in the system, in which case the end of the bus will be after the last device on the daisy chain. See the diagram below for connection examples (Fig.1). The termina-tor also must be rated for the proper SCSI specification that the system is supporting. The TranzStor 1Xi backplane contains a 4 position switch, which sets the SCSI ID. The SCSI ID must be set so that it is unique relative to any other devices that are connected to the same SCSI bus in-cluding the HBA. It is common for the HBA to use SCSI ID 7, so this address should generally not be used for the TranzStor 1Xi. The diagram below (Fig.1) shows how to set the SCSI ID switch.

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

13

(1) The listed maximum bus lengths may be exceeded in Point-to-Point and engineered applications.

(2) Use of the word “Narrow”, preceding SCSI, Ultra SCSI, or Ultra2 SCSI is optional.

(3) LVD was not defined in the original SCSI standards for this speed. If all devices on the bus support LVD, then 12-meters operation is possible at this speed. However, if any de-vice on the bus is singled-ended only, then the entire bus switches to single-ended mode and the distances in the single-ended column apply.

(4) Single-ended is not defined for speeds beyond Ultra.

(5) HVD (Differential) is not defined for speeds beyond Ultra2.

(6) After Ultra2 all new speeds are wide only.

SCSI Bus with Single Device

SCSI Bus with Multiple Device

SCSIHBAID=7

Terminator

TranzStor 1Xi ID=0

SCSITape Drive

ID=2

SCSIHBAID=7

Terminator

TranzStor 1Xi ID=1

SCSI CDROM ID=0

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

14

0 0 0 0 00 0 0 1 10 0 1 0 20 0 1 1 30 1 0 0 40 1 0 1 50 1 1 0 60 1 1 1 71 0 0 0 81 0 0 1 91 0 1 0 101 0 1 1 111 1 0 0 121 1 0 1 131 1 1 0 141 1 1 1 15

4 3 2 1

Switch # SCSIID

SCSI Switch Settings

INSTALLATION

Doc# 27-0014UM Rev B Issued 07/05

15

The locking handle will spring open

Gently pull the handle towards you to extract the TP7 from the connector and carefully pull out the TP7

With your thumb slide the locking catch to the right to release the locking handle

Extruded Body

Sliding locking catch

Locking catch

Locking handle

SCSI or IDE identification

Locking handle in open position

REMOVING THE TRANZPAK 7 FROM THE TRANZSTOR 1XI

Bezel

TRANZPAK 7 OVERVIEW

The TP7 is tested and qualified for operating temperature limits as low as -32˚ Celsius (with heater). A -32˚ C maximum requires a 35 minute warm up. The TP7 is qualified for -20˚ C for continuous operation.

OPERATIONS

Doc# 27-0014UM Rev B Issued 07/05

16

INSERTING THE TRANZPAK 7 INTO THE TRANZSTOR 1XI

Push the TranzPak 7 all the way into the docking bay until you feel it seating on the connector.

Push the handle in until you hear the locking catch snap into place. The TranzPak 7 is now firmly locked in operating position.

DANGER: To avoid shock hazard: • The power cord plug must be

connected to a properly wired and grounded power outlet.

• Any equipment to which the TranzStor 1Xi will be attached must also be connected to properly wired and grounded power outlets.

TRANZSOR 1XI STATUS LEDS

The 1Xi LED states are interpreted in the following manner:

Green LED: The green light indicates drive power.

• ON, solid light, no flashing: The drive is inserted and has power.• FLASHING, 20%: The drive is being heated.The drive will not start until the heat cycle completes. • FLASHING, 80%: The drive is in a reheat cycle. The drive continues to operate during a reheat cycle. • OFF: No power, or drive is removed.

Yellow LED: The yellow light represents drive activity.

• ON: IDE drives generally show a “busy” signal at startup, until the computer begins boot-ing.• FLICKERING: This is the controller’s “activity” signal.• OFF: No activity is detected.

OPERATIONS

Doc# 27-0014UM Rev B Issued 07/05

17

If the Z Microsystems Technical Support Engineer determines that the product needs to be replaced, a Customer Service Representative will issue a Return Material Authoriza-tion (RMA) number.

An RMA number is required to return a product to Z Microsystems, regardless of the reason for the return. The Z Microsystems Customer Service Department/RMA Request Form will ask the cus-tomer to provide the following information:

• model number

• serial number

• problem

• return “ship to” address

• the name and address of the company department to which we will send the invoice (if product is out of warranty or is different from the “ship to” address.

• phone number and e-mail address of contact

• purchase order number

You will be given an RMA number and will be asked to send the product to:Z Microsystems ATTN.: (RMA#) It is very important to reference the RMA# 5945 Pacific Center Dr., Suite 505 San Diego, CA 92121

REPLACING PARTS

REPLACEMENTS

Doc# 27-0014UM Rev B Issued 07/05

18

MECHANICAL DRAWINGS

1.7

5.860.43

8.16

5.2

2.1

Fit 4-40 screws, 2 each side

MECHANICAL OUTLINE FOR TRANZSTOR 1XI

Doc# 27-0014UM Rev B Issued 07/05

19

APPENDIX

SPECIFICATIONS HardwareStorage Capacity Up to 400 GB (drive dependent)Options SCSI or IDE Dimension 1.68” H, 5.71” W, 8.6” D Net Weight 2.9 lbs. (depending on device)

Environmental*Operating Temp +5º C to +40º C -30º (w/ heater option and 35 min warmup) to +40º C Non Operating Temp -40º to + 65º CHumidity 5% to 95% Non condensing Non Op. Altitude up to 40,000 ft. Operating Altitude up to 10,000 ft. Vibration MIL-STD-167 Shock MIL-STD-810E, Method 516, 30g’s Fungus Non Nutrients / contaminants

Reliability Operating Life 10 years Maintainability <20 minutes Safety UL 1950 as a guideline

Quality/Workmanship IPC / ISO 9002 and applicable section of MIL-HDBK-454

* Units are designed and built to meet the following environmental specifications. Results of tests are pending.

Doc# 27-0014UM Rev B Issued 07/05

20

APPENDIX

Z Microsystems’ one-year Standard Warranty includes a 90-day AirSpare Service Plan. This means that if any standard Z Microsystems’ product fails within the first 90 days after shipping, the customer will receive a new replacement. All non-standard* products are covered for one year under Z Microsystems’ Standard Warranty that includes free parts and labor. However, the 90-day AirSpare Plan can be purchased as an additional option for non-standard products.1-90 days - Z AirSpare Service

• 91-365 days - Free Parts and Labor

• 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

*a non-standard product is a prototype or a product specifically designed or engineered per a customer’s specification To return a defective product a customer can call the Z Microsystems Customer Ser-vice Department at 1-858-657-1000, ext. 232, or fill out the RMA Request Form on our website. Please see the section in this manual titled, “Replacements” for details on how to replace a part.

Standard Warranty-no charge-

WARRANTIES

Doc# 27-0014UM Rev B Issued 07/05

21

APPENDIX

Z Microsystems’ Extended Warranty Plan provides one and two year extended warranty options under which a Standard Warranty is extended from the end of the first year of the Standard Warranty period. The One-Year Extended Warranty period will begin on the day the Standard Warranty expires and the Two-Year Extended Warranty begins when the One-Year Extended War-ranty expires. 1-90 days - Z AirSpare Service91-365 days - Free Parts and Labor

• 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

2nd year - Free Parts and Labor • 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

3rd year - Free Parts and Labor • 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

Z Extended Warranty

Doc# 27-0014UM Rev B Issued 07/05

22

APPENDIX

Z Microsystems provides a Preferred Service Plan under which Z Microsystems will repair or replace and return a defective product to the customer within one week of Z Microsys-tems’ receipt of the defective product. 1-90 days - Z AirSpare Service91-365 days - Free Parts and Labor

• 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

• Guaranteed One Week Turnaround

2nd year - Free Parts and Labor • 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

• Guaranteed One Week Turnaround

3rd year - Free Parts and Labor • 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

• Guaranteed One Week Turnaround

Z Preferred Warranty

Doc# 27-0014UM Rev B Issued 07/05

23

APPENDIX

Z Microsystems provides an AirSpare Service Plan that will replace a defective product, within the first year of the warranty period, with a new product the following business day.* The AirSpare Service Plan does not cover special order items. A product may be deemed a special order item at the discretion of the Customer Service Department. Z Microsys-tems, at its discretion, may offer the AirSpare Service Plan to a customer who purchases a special order item at the one-year rate. *Z Microsystems cannot guarantee next day delivery if contacted after 2:00 PM Pacific Time. Calls on Fridays or before holidays will receive a new product the following busi-ness day. 1st Year - 24 hour replacement

• 9-5 PST telephone technical assistance

• Online technical help

• Email product updates

2nd Year - 24 hour replacement • 9-5 PST telephone technical assistance

• Online technical help

• email product updates

Z Airspare Warranty

365 DAYS

Doc# 27-0014UM Rev B Issued 07/05

24

APPENDIX

Z Microsystems also provides on site service and consultation to customers who require Z Microsystems’ technical expertise.

Z On-Site Service

Doc# 27-0014UM Rev B Issued 07/05

25

APPENDIX

DisclaimerZ Microsystems warrants that every product is free from defects in materials, workman-ship and conforms to Z Microsystems’ stringent specifications.

Z Microsystems calculates the expiration of the warranty period from the date the product is shipped. This means that the ship date on your invoice is your product ship date unless Z Microsystems informs you otherwise. During the warranty period, Z Microsystems will provide warranty service under the type of warranty purchased for the product.

Replacement parts will assume the remaining warranty of the parts they replace. If a product does not function as warranted during the warranty period, Z Microsystems will repair or replace the part (with a product that is as a minimum functionally equivalent) without charge.

If the product is transferred to another user, the warranty service is available to that user for the remainder of the warranty period. Z Microsystems’ warranties are voided if the covered product is damaged due to an ac-cident or abuse. The warranty is voided if the product is shipped in sufficient packaging.

Under no circumstances is Z Microsystems liable for any of the following:1. Third-party claims against you for losses or damages,

2. Loss of, or damage to, your records or data, or

3. Economic consequential damages (including lost profits or savings) or incidental damages, even if Z Microsystems is informed of their possibility.

Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from jurisdiction to jurisdiction.

Warranty does not take effect until full payment is received by Z Microsystems.

Doc# 27-0014UM Rev B Issued 07/05

26

APPENDIX

If you are unable to correct the problem yourself, contact:

Z Microsystems at: (858) 657-1000 Fax: (858) 657-1001 Website: www.zmicro.comBefore calling, please have available as much of the following information as pos-sible:

1. Model and serial number from the label on the monitor.

2. Purchase P.O.

3. Description of problem

4. Computer type and model

5. System configuration (hardware fit-ted, etc.)

6. System BIOS version number

7. Operating System and version number

8. Display driver version number

9. Video Adapter Type

NOTE: If possible, stay by the computer. The Z Microsystems Technical Support Representative may wish to go through the problem over the telephone.

NOTE: More help, late-breaking news and details of the latest accessories for these products may be found on the worldwide web at: http://www.zmicro.com