6
24000, 3/2 Direct solenoid actuated direct poppet valves 9/18 en 5.4.339.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbH Medium: For neutral, gaseous and liquid fluids Operation: Direct solenoid operated poppet valves Operating pressure: 100 bar (1450 psi) max. Orifice: 8 ... 50 mm Port size: G1/4 ... G1 1/2 Mounting position: Solenoid group 30,5A: optional, otherwise vertical Flow direction: Optional Ambient temperature: -25°, -40° ... +60°, +80°, +90°C Fluid temperature: NBR: -25° ... +80°C (-13° ... 176°F) TPE: -40° ... +80°C (-40° ... +176°F) Depending on solenoid system and sealing Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Housing: Brass, red brass (Rg), grey cast iron (GG) Seat seal: see Fluid temperature Inner part: Brass, steel Further versions: Manual override with push button or detent Flow conversion: Cv US Gallon/min (water) = l/min (air) x 0,001 Kv m³/h (water) = l/min (air) x 0,000906 Technical features > Port size: G1/4 ... G1 1/2 > Working from 0 bar up > Suitable for vacuum range down to 1,33·10 -2 mbar·l/s > Protection class IP65, Ex em, Ex d (ATEX approved, see solenoid operators) > Suited for outdoor installation Technical data Symbol Port size Solenoid Group Orifice (mm) Operating pressure min. (bar) kv-value (Cv (US) ≈ kv x 1,2 Material Housing Seat seal Weight (kg) Dimensions No. Model *1) 2 1 3 G1/4 30,5A 8 0 ... 15 0,65 Brass NBR 2,6 1 2401550 G1/4 30,5B 8 0 ... 15 0,65 Brass NBR 4,5 1 2401546 G3/8 30,5A 8 0 ... 15 0,77 Brass NBR 2,6 1 2401650 G1/2 30,5A 8 0 ... 15 0,78 Brass NBR 2,6 1 2401750 G1/2 30,5B 8 0 ... 15 0,65 Brass NBR 4,5 1 2401746 G3/8 30,5A 12 0 ... 12 1,12 Brass NBR 3,0 1 2402450 G1/2 30,5A 12 0 ... 12 1,25 Brass NBR 3,0 1 2402550 G1/2 38,5A 12 0 ... 25 1,25 Brass NBR 4,2 2 2402750 G1/2 38,5A 12 0 ... 40 1,25 Brass NBR 4,2 2 2406750 G1/2 38,5A 12 0 ... 100 1,25 Brass Stainless steel *2) 4,2 2 2407965 G1/2 30,5B 12 0 ... 12 1,25 Brass NBR 4,8 1 2402556 G1/2 30,5B 12 0 ... 10 1,25 Brass TPE 2,4 1 2402576 G1/2 38,5B 12 0 ... 25 1,25 Brass NBR 5,2 2 2402758 G1/2 38,5B 12 0 ... 40 1,25 Brass NBR 5,2 2 2406756 G1/2 38,5A 15 0 ... 10 2,80 Red brass NBR 6,2 3 2403350 G1/2 38,5B 15 0 ... 10 2,80 Red brass NBR 7,7 3 2403358 G3/4 38,5A 15 0 ... 10 2,80 Red brass NBR 6,2 3 2403450 G3/4 38,5B 15 0 ... 10 2,80 Red brass NBR 7,7 3 2403458 G3/4 38,5A 20 0 ... 6 5,00 Red brass NBR 7,7 4 2403510 G3/4 38,5B 20 0 ... 6 5,00 Red brass NBR 9,1 4 2403514 G1 38,5A 20 0 ... 10 5,00 Red brass NBR 7,7 4 2403610 G1 38,5B 20 0 ... 10 5,50 Red brass NBR 9,1 4 2403614 G1 70A 25 0 ... 8 9,00 Red brass NBR 22,9 5 2403810 G1 1/4 70A 25 0 ... 8 9,00 Red brass NBR 22,9 5 2403910 G1 1/2 70A 50 0 ... 3 25,0 Grey cast iron *3) NBR 36,3 6 2404010 *1) When ordering please indicate solenoid, voltage and current Modele (frequency). *2) Suitable for liquids only *3) Grey cast iron suitable for fluid and ambient temperatures down -10°C.

24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

  • Upload
    dokhue

  • View
    243

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

24000, 3/2 Direct solenoid actuated direct poppet valves

9/18en 5.4.339.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbH

Medium:For neutral, gaseous and liquid fluidsOperation:Direct solenoid operated poppet valvesOperating pressure:100 bar (1450 psi) max. Orifice:8 ... 50 mm Port size:G1/4 ... G1 1/2

Mounting position:Solenoid group 30,5A: optional, otherwise verticalFlow direction:OptionalAmbient temperature:-25°, -40° ... +60°, +80°, +90°CFluid temperature:NBR: -25° ... +80°C (-13° ... 176°F) TPE: -40° ... +80°C (-40° ... +176°F) Depending on solenoid system and sealing

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used!

Materials:Housing: Brass, red brass (Rg), grey cast iron (GG) Seat seal: see Fluid temperature Inner part: Brass, steelFurther versions:Manual override with push button or detentFlow conversion:Cv US Gallon/min (water) = l/min (air) x 0,001Kv m³/h (water) =l/min (air) x 0,000906

Technical features

> Port size: G1/4 ... G1 1/2

> Working from 0 bar up

> Suitable for vacuum range down to 1,33·10-2 mbar·l/s

> Protection class IP65, Ex em, Ex d (ATEX approved, see solenoid operators)

> Suited for outdoor installation

Technical dataSymbol Port

sizeSolenoidGroup

Orifice

(mm)

Operating pressure min. (bar)

kv-value(Cv (US) ≈ kv x 1,2

Material

Housing Seat seal

Weight

(kg)

Dimensions No.

Model *1)

2

1 3

2

1 3

2

1 3

G1/4 30,5A 8 0 ... 15 0,65 Brass NBR 2,6 1 2401550

G1/4 30,5B 8 0 ... 15 0,65 Brass NBR 4,5 1 2401546

G3/8 30,5A 8 0 ... 15 0,77 Brass NBR 2,6 1 2401650

G1/2 30,5A 8 0 ... 15 0,78 Brass NBR 2,6 1 2401750

G1/2 30,5B 8 0 ... 15 0,65 Brass NBR 4,5 1 2401746

G3/8 30,5A 12 0 ... 12 1,12 Brass NBR 3,0 1 2402450

G1/2 30,5A 12 0 ... 12 1,25 Brass NBR 3,0 1 2402550

G1/2 38,5A 12 0 ... 25 1,25 Brass NBR 4,2 2 2402750

G1/2 38,5A 12 0 ... 40 1,25 Brass NBR 4,2 2 2406750

G1/2 38,5A 12 0 ... 100 1,25 Brass Stainless steel *2) 4,2 2 2407965

G1/2 30,5B 12 0 ... 12 1,25 Brass NBR 4,8 1 2402556

G1/2 30,5B 12 0 ... 10 1,25 Brass TPE 2,4 1 2402576

G1/2 38,5B 12 0 ... 25 1,25 Brass NBR 5,2 2 2402758

G1/2 38,5B 12 0 ... 40 1,25 Brass NBR 5,2 2 2406756

G1/2 38,5A 15 0 ... 10 2,80 Red brass NBR 6,2 3 2403350

G1/2 38,5B 15 0 ... 10 2,80 Red brass NBR 7,7 3 2403358

G3/4 38,5A 15 0 ... 10 2,80 Red brass NBR 6,2 3 2403450

G3/4 38,5B 15 0 ... 10 2,80 Red brass NBR 7,7 3 2403458

G3/4 38,5A 20 0 ... 6 5,00 Red brass NBR 7,7 4 2403510

G3/4 38,5B 20 0 ... 6 5,00 Red brass NBR 9,1 4 2403514

G1 38,5A 20 0 ... 10 5,00 Red brass NBR 7,7 4 2403610

G1 38,5B 20 0 ... 10 5,50 Red brass NBR 9,1 4 2403614

G1 70A 25 0 ... 8 9,00 Red brass NBR 22,9 5 2403810

G1 1/4 70A 25 0 ... 8 9,00 Red brass NBR 22,9 5 2403910

G1 1/2 70A 50 0 ... 3 25,0 Grey cast iron *3) NBR 36,3 6 2404010

*1) When ordering please indicate solenoid, voltage and current Modele (frequency). *2) Suitable for liquids only *3) Grey cast iron suitable for fluid and ambient temperatures down -10°C.

Page 2: 24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

24000, 3/2 Direct solenoid actuated direct poppet valves

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbHen 5.4.339.02

9/18

Solenoid operators Solenoids group 30,5A

Power consumption24 V d.c. 230 V a.c.(W) (VA)

Rated current

24 V d.c. 230 V a.c.(m A) (m A)

Protection classIP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Media(°C)

Electricalconnection

Drawing

No.

Circuitdiagram

No.

Model

21,4 — 891 — IP65 (with cable gland)

— -25...+60 M20 x 1,5 21 2 1300

— 22,8 — 99 IP65 (with cable gland)

— -25...+60 M20 x 1,5 21 6 1301

21,4 — 891 — IP65 (with cable gland)

II 2G Ex eb mb IIC T4/T5 GbII 2D Ex tb IIIC T120°C Db

T4: -20 … +80°CT5: -40 … +60°C-20 … +80°C

M20 x 1,5 22 4 1440

— 22,8 — 99 IP65 (with cable gland)

II 2G Ex eb mb IIC T4/T5 GbII 2D Ex tb IIIC T120°C Db

T4: -20 … +80°CT5: -40 … +60°C-20 … +80°C

M20 x 1,5 22 7 1441

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. IP66 version on request

Solenoids group 30,5BPower consumption24 V d.c. 230 V a.c.(W) (VA)

Rated current

24 V d.c. 230 V a.c.(m A) (m A)

Protection classIP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Media(°C)

Electricalconnection

Drawing

No.

Circuitdiagram

No.

Model

21,4 — 891 — IP66 (with cable gland)

II 2 G Ex d IIC T4 GbII 2 D Ex tb IIIC T90°C Db

-40...+60 1/2 NPT *6) 29 2 1480

— 22,8 — 99 IP66 (with cable gland)

II 2 G Ex d IIC T4 GbII 2 D Ex tb IIIC T90°C Db

-40...+60 1/2 NPT *6) 29 6 1481

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *6) Cable gland not supplied, see table »Accessories«

Solenoids group 38,5APower consumption24 V d.c. 230 V a.c.(W) (VA)

Rated current

24 V d.c. 230 V a.c.(m A) (m A)

Protection classIP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Media(°C)

Electricalconnection

Drawing

No.

Circuitdiagram

No.

Model

38,7 — 1614 — IP65 (with cable gland)

— -25...+60Fluid max. +80

M20 x 1,5 23 2 1500

— 42,1 — 169 IP65 (with cable gland)

— -25...+60Fluid max. +80

M20 x 1,5 23 6 1501

38,7 — 1614 — IP65 (with cable gland)

II 2G Ex eb mb IIC T4 Gb -20...+40 M20 x 1,5 *6) 24 2 1570

— 42,1 — 169 IP65 (with cable gland)

II 2G Ex eb mb IIC T4 Gb -20...+40 M20 x 1,5 *6) 24 6 1571

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. IP66 version on request

Page 3: 24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbH

24000, 3/2 Direct solenoid actuated direct poppet valves

en 5.4.339.039/18

ApprovalsModel Approvals

ATEX IECExDatasheet

144x KEMA 03 ATEX 1016 X IECEx DEK 11.0066X 7.1.510

148x, 168x BVS 12 ATEX E 068 X — 7.1.515

157x DEKRA BVS 08 ATEX E 117 — 7.1.520

Solenoids group 38,5BPower consumption24 V d.c. 230 V a.c.(W) (VA)

Rated current

24 V d.c. 230 V a.c.(m A) (m A)

Protection classIP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Media(°C)

Electricalconnection

Drawing

No.

Circuitdiagram

No.

Model

35,9 — 1497 — IP66 (with cable gland)

II 2 G Ex d IIC T4 GbII 2 D Ex tb IIIC T105°C Db

-40...+60 1/2 NPT *6) 29 2 1680

— 38,9 — 169 IP66 (with cable gland)

II 2 G Ex d IIC T4 GbII 2 D Ex tb IIIC T105°C Db

-40...+60 1/2 NPT *6) 29 6 1681

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *6) Cable gland not supplied, see table »Accessories«

Solenoids group 70APower consumption24 V d.c. 230 V a.c.(W) (VA)

Rated current

24 V d.c. 230 V a.c.(m A) (m A)

Protection classIP

Ex-Protection(ATEX-Category)

TemperatureAmbient/Media(°C)

Electricalconnection

Drawing

No.

Circuitdiagram

No.

Model

69,2 — 2882 — IP65 (with cable gland)

— -40...+60Fluid max. +100

M20 x1,5 *6) 26 2 1800

— 78,8 — 343 IP65 (with cable gland)

— -40...+60Fluid max. +100

M20 x1,5 *6) 26 6 1801

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *6) Cable gland not supplied, see table »Accessories«

AccessoriesATEX-Cable gland

For Solenoid Port size Cable ø Protection class Model

157x M20 x1,5 5,0 … 8,0 mm II 2G Ex e / II 2D Ex t 0588819

148x, 168x 1/2 NPT 7,5 … 11,9 mm II 2G Ex d / II 2D Ex t 0588925

Partnumbers for international approvalLand/Approval Coil/Code 144x 148x/168x 157x

Europa/ATEX Standard x x x

International/IECEx Standard x x x

China/NEPSI -01 – – –

Brasilien/INMETRO -02 – x –

Korea/KOSHA (only gas approval) -03 – – –

Russland, Kasachstan & Weißrussland/TR-CU 012 -04 x x x

Page 4: 24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

24000, 3/2 Direct solenoid actuated direct poppet valves

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbHen 5.4.339.04

9/18

Valve dimensions

Dimension No.

A C D E H J K L M N P R

3 100 126 63,5 19,5 30 15 13,5 50 M10 12 39 77

4 120 156 80 30 30 15 15 70 M10 12 42 82

5 132 184 96 36 40 20 15 100 M12 12 57 102

6 240 239 135 45 80 40 33 130 M16 21 98 171

1 Solenoid dimensions see page 5 2 For port size, see general information3 Depending on solenoid system

1

3

5

2

4

6

27,5

70

2

1

3

40

ø 6

,5

13

67,5

A

47,5

38

56

2

1

3

E

A

21

3

M

KLD

C

N

P

R

H

J

2

1

3

Dimensions in mm Projection/First angle

Dimension No.

A

1 108

2 115

Page 5: 24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

26

M 2

0 x

1,5

130

187,

5

ø 48

ø 154

21

23

22

24

ø 30,5

M 2

0 x

1,5

78

125

ø 86

M 2

0 x

1,5

113

ø 86

ø 30,5

161

M 2

0 x

1,5

~ 14

3

82

ø 38,7

ø 92

M20

x 1

,5

183

+1

134

ø 38,7

ø 92

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbH

24000, 3/2 Direct solenoid actuated direct poppet valves

en 5.4.339.059/18

Dimensions Dimensions in mm Projection/First angle

Weight: 1,35 kg Weight: 2,0 kg

Weight: 2,5 kg Weight: 3,6 kg

Weight: 11,2 kg

Page 6: 24000, 3/2 Direct solenoid actuated direct poppet valvescdn.norgren.com/pdf/en_5_4_339_24000_EPN.pdf · Direct solenoid actuated direct poppet valves 9/18 ... 8 9,00 Red brass NBR

1

155

100 1/2

NP

T

85

M 8

154

12

141,5

503

66

65

~

29

24000, 3/2 Direct solenoid actuated direct poppet valves

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2004 - 5132h) © 2015 Norgren GmbHen 5.4.339.06

9/18

Circuit diagrams

A B C ø D Model

M20 x 1,5 9 36 5 ... 8 22 0588819

1/2-14 NPT 15 58 7,5 ... 11,9 24 0588925

Cable gland

0588925 only

1 Solenoid 148x ø 30,5 mm Solenoid 168x ø 38,7 mm

C

A

B D

C

A

B D

2 4 6 7

WarningThese products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren GmbH.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.

Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden. Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-Daten« aufgeführten Werte nicht überschritten werden. Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenser-

Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an IMI Precision Engineering, Norgren GmbH.Durch Missbrauch, Verschleiß oder Störungen können in Pneumatik-

systemen verwendete Komponenten auf verschiedene Arten versagen.Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berück-

Verletzungen von Personen sowie Beschädigungen der Geräte im Falle einer solchen Störung zu verhindern. Systemausleger sind verpflichtet, Sicherheitshinweise für den End-benutzer im Betriebshandbuch zu vermerken, wenn der Störungs-schutz nicht ausreichend gewährleistet ist.

Dimensions in mm Projection/First angleWeight 148x: 3,3 kg, 168x: 4,2 kg 1,35 kg