12
1 3-4 Sept. 2008 EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL [email protected]

2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL [email protected]

Embed Size (px)

Citation preview

Page 1: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

1 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU Chassis

Mechanical Design and Development

Bill Donakowski

Mechanical Engineer

UCB/SSL

[email protected]

Page 2: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

2 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisRequirements

• Functional– Provide Mechanical Packaging for 4 EFW electronic boards in one card cage box– BEB/DFB/DCB/LVPS Boards– Allow removal of each board layer separately– Provide structure and attachment to S/C– All access to test points following board installation into box

• Structural– Positive strength margins– First natural frequency greater than 50 Hz

• Radiation Shielding– External walls to have .35” equivalent thickness Aluminum– LOS requirement from outside to boards

• Venting– Allow proper venting on ascent

• Thermal– Alodined Box attach face is conductively attached to S/C Panel 5– All other outer surfaces black anodized to radiatively couple to inside of S/C– Temperature range: -35° C to +65° C (preliminary)

• EMI Shielding– Provide metal shielding between each board layer

Page 3: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

3 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU Chassis Design Description

• Standard card-cage design– Standard 6U format circuit boards (160mm x 230mm)

– Similar to THEMIS

– Aluminum 6061 T6 panels bolted together

– gaps prevented at panel interface by step in edges

• Separate layers for individual boards to slide into box– Each card layer consists of PCB, wedgelocks, connectors, and EMI shield

– Cards held in place by wedgelocks on sides and fasteners on front panels

– Each panel can be removed by unscrewing bolts, loosening wedgelocks, and sliding out

• Separate, removable radiation shield over connectors and cables– Installed for testing and at integration to S/C

– Aluminum 6061-T6

Page 4: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

4 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisOverview

LVPS

DFB

DCB

BEB

REMOVABLE RADIATION SHIELD

HOLES FOR BOLTING TO S/C PANEL #5 (10-32 bolts)

ALL CABLES TO S/C MATE TO FRONT OF BOX

TOTAL MASS: CBE 8.3 Kg

10”

VENT3.5”

7.5”

4.2”

Page 5: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

5 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisOverview

WEDGELOCKS ON EACH BOARD EDGE

(manuf: CALMARK)

EACH BOARD CAN BE REMOVED INDIVIDUALLY

(without removing others)

Page 6: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

6 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisOverview

REMOVABLE RADIATION SHIELD

(INSTALLED FOLLOWING BOX INTEGRATION ONTO S/C)

BACKPLANE CONNECTOR ACCESS PANEL TO TEST POINTS ON BOARDS

8 x ATTACH BOLTS

(8-32)

Page 7: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

7 3-4 Sept. 2008 EFW INST+SOC PDR

RBSP ChassisRadiation Shielding

• All external aluminum panels provide shielding– .35” thickness

– Interlocking steps to prevent any gaps at connections

• Removable Radiation Shield covers connectors and cables on front of box– Radiation Shield installs following box installation onto S/C

– Provides .35” equivalent thickness radiation shielding line of sight to boards

Volume for cable run to S/C

EMI SHIELDS BETWEEN LAYERS

( 3 SHIELDS)

Page 8: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

8 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisRadiation Scheme for Cables

• Radiation LOS Maze allows simple cable runs

.90”

Pass-thru for cables to S/C

Page 9: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

9 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisAnalysis

• Structural– Thick wall sections for radiation shielding makes for very robust box– Preliminary strength analysis strength margins > .7 on yield (100G)

• Venting– Volumetric analysis to confirm– Vent size 1 in2 for every 1 ft3 Volume– Size vent accordingly

Preliminary FEM output

Showing Von Mises Stresses

Page 10: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

10 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisStatus

• ICD drawing submitted to APL – Overall box geometry

– Cable routing

– Keep-out zones to allow radiation shield installation on S/C

• Individual Board ICDs completed– Showing connectors, board geometry

– Allowing electrical components layouts to begin

• Mechanical Box detailing ongoing– Weight relieving of .35” walls to be implemented where possible

Page 11: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

11 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU ChassisIssues and Concerns

• Thick walled construction produces rapid mass gain if box grows

Page 12: 2053-4 Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL billd@ssl.berkeley.edu

12 3-4 Sept. 2008 EFW INST+SOC PDR

IDPU Chassis (backup)Materials

• 6061-T6 Aluminum Alloy– Yield Strength: 37,000 psi

– Ultimate Tensile Strength: 42,000 psi

• Delrin– Ultimate Tensile Strength: 8,000 psi