New Safe-T-Cover Enclosure options for North Carolina

Safe-T-Cover has created new enclosure models for the most popular backflow

preventers that are optimized to be the Best overall value.

All are manufactured from aluminum and will last for decades. They all have

oversized front access panels and a roof that hinges open and locks straight up

(90 degrees) for maximum access. All new models meet the ASSE 1060 standard.

These new models are Not on our website. A sizing guide of these same backflow

preventers in all other standard aluminum enclosures can be viewed at

http://www.safe-t-cover.com/enclosures/search.

Here is the simple selection guide for the new models that fit 3”, 4” and 6”

backflow preventers.

BFP Model Best SN fit/inside dimensions

3”and 4” All Watts 757 series* 304SNT-AL: 27”W x 65”L x 49”H 3” and 4” All Watts 957 series* 304SNT-AL: 27”W x 65”L x 49”H 3” and 4” All Wilkins 350 series* 304SNT-AL: 27”W x 65”L x 49”H 3” and 4” All Wilkins 375 series* 304SNT-AL: 27”W x 65”L x 49”H

6” All Watts 757 series* 400SNT-AL: 27”W x 78”L x 57”H 6” All Watts 957 series* 400SNT-AL: 27”W x 78”L x 57”H 6” All Wilkins 350 series* 400SNT-AL: 27”W x 78”L x 57”H 6” All Wilkins 375 series* 400SNT-AL: 27”W x 78”L x 57”H *Without WYE strainer Use our website selection guide for 8” through 12” backflow preventers.

Page 3: 2016 Safe-T-Cover Sales Package

• Permanently anchored enclosures for backflow preventers 4” through 10”

• Removable front door and lift up roof for easy access

• The hinged roof locks in place at 90 degrees - straight up

• Certified to ASSE 1060 Standard

• R-9 insulation

• Easy installation

• Shipped flat to minimize freight costs

Front and Roof Access Enclosures

ASSE Standard 1060 approved

Page 4: 2016 Safe-T-Cover Sales Package

Nashville, TN Phone 800-245-6333 Fax 615-259-4481 www.safe-t-cover.com

Model Inside Dimensions Concrete Pad Weight Drain Opening

300SNT-AL 24” x 60” x 45” 38” x 74” x 6” 186# 45” x 5 7/8”

304SN-AL 20” x 65” x 42” 34” x 79” x 6” 178# 45” x 5 7/8”

304SNT-AL 27” x 65” x 49” 41” x 79” x 6” 219# 45” x 5 7/8”

400SNT-AL 27” x 78” x 57” 41” x 92” x 6” 268# 45” x 5 7/8”

406SN-AL 27” x 78” x 47” 31” x 92” x 6” 223# 45” x 5 7/8”

408SN-AL 30” x 100” x 57” 44” x 114” x 6” 318# 45” x 5 7/8”

410SN-AL 30” x 112” x 57” 44” x 126” x 6” 357# 45” x 5 7/8”

Specification Submittal Sheet

Series 300/400 SNInsulated Enclosures

DescriptionThe SN series is developed as an enclosure thatmounts to a concrete pad, has a removable front door and the top hinges and locks to 90 degrees. These SN models ship in a flat box to minimize freight costs.

SpecificationsA freeze and vandal protective enclosure shall be installed over above ground plumbing systems. The enclosure shall be constructed of 5052-H32 marine grade aluminum with a minimum R-9 in the walls and roof. Cut board insulation shall be used to insure uniform insulation thickness. Sprayed insulation shall be reason for rejection. The enclosure shall havea fully insulated drain panel designed to remain closed except when the backflow prevention assembly isdischarging water. The drain panel shall be sized to accomodate the maximum discharge for backflow installations.The enclosure shall be mounted securely to a concrete pad and remain locked even if outside screws are removed.All mounting hardware shall be furnished. When heat is required, a UL or ETL listed heater shall be provided that has been independently certified to meetthe UL-2021 “Rain Test” for damp or wet conditions. The enclosure shall be certified to meet the most recent ASSEStandard 1060 (Class I or II). The insulated enclosure shall be a Safe-T-Cover SN or SNT Series

Materials• Roof, walls, drain flap – 5052-H32 marine grade aluminum (.050/18 gauge), mill finish, ASTM B209 outside• Drain panel hinge and spring – stainless steel• Insulation 1.5” (9 R value) minimum thickness polyisocyanurate foam laminated to a glass fiber reinforced facer (each side)• Mounting hardware – 5052-H32 marine grade aluminum• Masonry fasteners – stud-type Powers SD1 wedge anchors

Standards• ASSE 1060• ASTM B209

Advantages• Fast and simple installation, no special tools required• Durable• Lockable

Heating Required‘ Yes – see separate specification submittal sheet‘ No

Dimensions and Weights

SN 1115M

Page 5: 2016 Safe-T-Cover Sales Package
Page 6: 2016 Safe-T-Cover Sales Package
Page 7: 2016 Safe-T-Cover Sales Package
Page 8: 2016 Safe-T-Cover Sales Package
Page 9: 2016 Safe-T-Cover Sales Package
Page 10: 2016 Safe-T-Cover Sales Package
Page 11: 2016 Safe-T-Cover Sales Package

Model Inside Dimensions Concrete Pad Weight Drain Opening

300SNT-AL 24” x 60” x 45” 38” x 74” x 6” 186# 45” x 5 7/8”

304SN-AL 20” x 65” x 42” 34” x 79” x 6” 178# 45” x 5 7/8”

304SNT-AL 27” x 65” x 49” 41” x 79” x 6” 219# 45” x 5 7/8”

400SNT-AL 27” x 78” x 57” 41” x 92” x 6” 268# 45” x 5 7/8”

406SN-AL 27” x 78” x 47” 31” x 92” x 6” 223# 45” x 5 7/8”

408SN-AL 30” x 100” x 57” 44” x 114” x 6” 318# 45” x 5 7/8”

410SN-AL 30” x 112” x 57” 44” x 126” x 6” 357# 45” x 5 7/8”

Specification Submittal Sheet

Series 300/400 SNInsulated Enclosures

DescriptionThe SN series is developed as an enclosure thatmounts to a concrete pad, has a removable front door and the top hinges and locks to 90 degrees. These SN models ship in a flat box to minimize freight costs.

SpecificationsA freeze and vandal protective enclosure shall be installed over above ground plumbing systems. The enclosure shall be constructed of 5052-H32 marine grade aluminum with a minimum R-9 in the walls and roof. Cut board insulation shall be used to insure uniform insulation thickness. Sprayed insulation shall be reason for rejection. The enclosure shall havea fully insulated drain panel designed to remain closed except when the backflow prevention assembly isdischarging water. The drain panel shall be sized to accomodate the maximum discharge for backflow installations.The enclosure shall be mounted securely to a concrete pad and remain locked even if outside screws are removed.All mounting hardware shall be furnished. When heat is required, a UL or ETL listed heater shall be provided that has been independently certified to meetthe UL-2021 “Rain Test” for damp or wet conditions. The enclosure shall be certified to meet the most recent ASSEStandard 1060 (Class I or II). The insulated enclosure shall be a Safe-T-Cover SN or SNT Series

Materials• Roof, walls, drain flap – 5052-H32 marine grade aluminum (.050/18 gauge), mill finish, ASTM B209 outside• Drain panel hinge and spring – stainless steel• Insulation 1.5” (9 R value) minimum thickness polyisocyanurate foam laminated to a glass fiber reinforced facer (each side)• Mounting hardware – 5052-H32 marine grade aluminum• Masonry fasteners – stud-type Powers SD1 wedge anchors

Standards• ASSE 1060• ASTM B209

Advantages• Fast and simple installation, no special tools required• Durable• Lockable

Heating Requiredr Yes – see separate specification submittal sheetr No

Dimensions and Weights

Hydrocowl, Inc.Nashville, TN • Phone 1-800-245-6333

FAX (615) 259-4481 • www.safe-t-cover.com SN 1115M

Page 12: 2016 Safe-T-Cover Sales Package
Page 13: 2016 Safe-T-Cover Sales Package
Page 14: 2016 Safe-T-Cover Sales Package
Page 15: 2016 Safe-T-Cover Sales Package
Page 16: 2016 Safe-T-Cover Sales Package
Page 17: 2016 Safe-T-Cover Sales Package
Page 18: 2016 Safe-T-Cover Sales Package
Page 19: 2016 Safe-T-Cover Sales Package
Page 20: 2016 Safe-T-Cover Sales Package
Page 21: 2016 Safe-T-Cover Sales Package
Page 22: 2016 Safe-T-Cover Sales Package
Page 23: 2016 Safe-T-Cover Sales Package
Page 24: 2016 Safe-T-Cover Sales Package
Page 25: 2016 Safe-T-Cover Sales Package
Page 26: 2016 Safe-T-Cover Sales Package
Page 27: 2016 Safe-T-Cover Sales Package
Page 28: 2016 Safe-T-Cover Sales Package
Page 29: 2016 Safe-T-Cover Sales Package
Page 30: 2016 Safe-T-Cover Sales Package
Page 31: 2016 Safe-T-Cover Sales Package