56
2014 Application Selection and Cross-Reference Guide Residential Combustion

2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

2014Application Selection and Cross-Reference Guide

Residential Combustion

Page 2: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

2

Phone:

Residential Technical Support:

1-800-468-1502

Sales Support: 1-800-328-5111

Customer Service: 1-888-793-8193

Residential Zoning: 1-800-828-8367

Online:

www.customer.honeywell.com

www.forwardthinking.honeywell.com

www.literature.honeywell.com

Contractor PRO:

Phone: 1-800-919-4835

Fax: 1-800-745-4999

Exclusive Technical Support

for Contractor PRO members:

1-877-880-3383

www.contractorpro.com

Support

Online Tools

Find everything you need to be successful in selling

Honeywell products online. Product information,

cross-references, demos and more are available at

www.customer.honeywell.com.

Training

Honeywell offers a variety of on-site and web-based training options

at www.customer.honeywell.com.

Rewards

Make your business count with Honeywell's Contractor PRO™ Program.

Honeywell's Contractor PRO program gives contractors reward points

($) back on Honeywell purchases. Visit www.contractorpro.com for

more information.

Customer Service

Honeywell provides toll-free access to product

application, installation and support experts.

Technical Support: 1-800-468-1502

Customer Service: 1-888-793-8193

Sales Literature

With Honeywell, you’ll have access to sales materials that you can use to

help grow your business. Visit www.literature.honeywell.com.

Page 3: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

3

Gas

Co

ntr

ols Table Of Contents

New Products 4

Gas Controls

Gas Valves 6

SmartValve™ System Controls 10

Universal Pilot Burners 14

Thermocouples/Thermopiles 18

Ignition Modules 20

Glowfly® Universal Hot Surface Igniter 24

Universal Electronic Fan Timer 26

Universal Integrated Furnace Control 28

Fan and Limit Controls 34

oil/HydroniC Controls

Oil Primaries 36

Outdoor Reset 40

Aquastats® 42

AquaPump 48

HeatinG/CoolinG deviCes

Relays/Contactors/Transformers 50

Gas

Co

ntr

ols

Hea

tin

g/C

oo

ling

Dev

ices

Oil/

Hyd

ron

ic C

on

tro

ls

PAGE

Page 4: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

4

New for 2014

As an industry leader in innovation and new product development, Honeywell is always working to

provide solutions that make your job easier and more profitable. This heating season we're keeping that

commitment with several new products. The first of these is the introduction of two VR8215 Direct Ignition

Gas Valves. Together these two valves replace 61 OEM and competitor models so you can finish on

the first trip more frequently. This translates to fewer stocking trips, more jobs, and more money in your

pocket. Also new this year is a Universal Thermopile that combines all the most common accessories in

one package. Now you only have to stock one model and cover nearly any application you may encounter.

VR8215 Direct Ignition Gas Valves

Honeywell is excited to introduce two new gas valves that will replace most

slow and standard-opening VR8205 and VR8215 direct ignition gas valves.

These two new gas valves will replace over 61 OEM and competitor

controls, which translates to fewer stocking trips, more jobs, and more

money in your pocket.

Universal Thermopile

Honeywell has taken the guesswork out of stocking thermopiles with the

new Q313U3000 Universal Thermopile. We combined all of the most

popular accessories into one package to make your job easier. Now you

can stock one model and cover nearly any thermopile application you

encounter. This is just one more Honeywell solution to make your job easier

and more profitable.

Page 5: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

5

Universal ProductsIn the HVAC industry today time is money, particularly in the service department, and time lost is money lost.

Every time your tech can’t complete a job, you could lose money. Every time the tech has to head to the

supply house, you could lose money. Every time the tech can’t make it to that last call of the day because of

extra trips to the supply house, you could lose money. With a parts strategy that includes Honeywell’s Universal

product portfolio you’ll have the right part and you’ll make more money nearly every time!

The stocking recommendations included in this guide are shown by regional area, U.S. and Canada, and are

averaged by product sales. They should be adjusted accordingly to your business size and needs.

Universal Product

Residential Combustion univeRsal PRoduCts ReCommended inventoRy Guide

Product Line Universal Service Part

U.S.NorthEast

U.S. Mid-Atlantic

U.S. North-NW

U.S. South-SE

U.S. West

Canada Eastern

Canada Central - West

Direct Service Part Replacement (Gas

Valves)RECOMMENDED BRANCh INVENTORy

Igni

tion

C

ontr

ols

S9200U1000 10 10 10 10 10 6 6

S8610U3009 24 24 24 12 12 24 24

S8910U1000 10 10 10 3 6 6 6

y8610U4001 4 4 4 2 6

y8610U6006 6 6 6 2 6 2 2

Igni

ters Q3200U1004 20 20 20 20 20 20 20

Q3200U2002 6 6 6 6 6 6 6

War

m

Air

Li

mit

ST9120U10011 12 12 12 6 6 12 8

Ther

mo-

coup

le Q340A1090 (U.S.)100 100 100 20 20 100 100

Q340A1439 (Canada)

Gas

Val

ves

VR8200A2322 (Canada) 6 10

VR8200h1236 (Canada) 12 12

VR8345M4302 12 12 12 6 8 8 12

VR8304M3509

VR8304M4507

VR8305M3506

VR8300M4406 12 12 12 3 6 4 6VR8300A4508

VR8300A3500

VR8245M2530 3 3 6 2 2 6 8

VR8204A2076

VR8204M1091

VR8205A2024

VR8345K4809 3 3 3 2 2 2 2VR8205h1003

VR8304h4503

VR8345Q4563 2 2 2 NA NA 1 2

VR8205Q2555

VR8304Q4511

VR8305Q4500

VS820M1309 6 6 6 NA 34

(VS820A1054)6

(VS820A1054)

VS820A1054

VS820A1336

Hyd

roni

c C

ontr

ols L7224U1002 18 18 2 NA NA 12 8

W8735y1000 6 6 2 NA NA 6 4

W8735S1008 6 6 2 NA NA 6 4

Oil

Con

trol

s

R7284U1004 10 10 4 NA NA 12 4

Uni

vers

al

Pilo

t Bur

ners Q314U1001 12 6 12 6 12 12 12

Q345U1005 12 6 12 6 12 12 12

Q348U1009 12 6 12 6 12 12 12

Q3451U1000 12 6 12 6 12 12 12

Page 6: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

6

Gas Valves

Honeywell has taken the guesswork out of gas valve selection with our complete line of universal

gas valves. Contractors appreciate the reliability, ease of installation and time saved by carrying a

select few gas valves on their truck. Carrying a few Honeywell Universal gas valves on each truck

reduces the amount of inventory needed while still making sure technicians can complete the job

in one trip. Honeywell's tried and tested gas valves ensure you will be getting the best product

available on the market, every time.

VR8345/VR8245Universal Electronic Ignition Gas Valve• Wide-capacity controls for almost any IP, HSI or DSI gas-fired appliances

• Compact fit simplifies field replacement

• Use with 24 Vac, 50/60 Hz, heating appliances, using natural, manufactured

or LP gas

• Use the VR8345Q for a two-stage application, VR8345M for

a standard and VR8345K for a slow-opening application

• Capacities from 20 to 200 (VR8245) cfh or 30 to 415 (VR8345) cfh

natural gas

• Dual-redundant gas valve design

Page 7: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

7

VR8300Universal Standing Pilot Gas Valve• Combination gas controls for use in 24 Vac, 50/60 Hz, gas-fired,

standing pilot appliances with capacities from 30 to 300 cfh natural gas

• Includes safety shutoff, manual valve, two automatic

operators, pressure regulator and pilot adjustment

• Universal replacement for most Honeywell and competitive

standing pilot valve models

• Dual-redundant gas valve design

VS820Millivolt Combination Gas Valve• Self-powered automatic control

• Use with 750 mV pilot generator

• Easy to install and service with all the adjustments and

connections accessible from the top of the control

• 34 to 425 cfh capacity

Gas

Co

ntr

ols

Scan here for installation and

product information.

VR8215Direct Ignition Gas Valve• Combination gas controls for use in 24 Vac, 50/60 Hz, single stage,

direct ignition, gas fired appliances

• Capacities from 15 to 200 cfh natural gas

• Multipoise – can be mounted in any direction

• 2.35 inch swing radius

• Dual-redundant gas valve

Page 8: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

8

WW

Gas Valves Selection Guide

tRade RePlaCements (double-Check specifications

before Replacement)sPeCifiCations aCCessoRies

Universal Service Part

Direct Service Part Replacement

Opening Characteristics (standard, step)

Inlet/Outlet

Size (in.)

Pressure Regulator Setting (psi)

Temperature Range

Includes

Q340 Thermocouple

3/4" x 1/2" Reducer Bushing

Natural to LP Conversion Kit

3/4" Straight Flange

1/2" x 3/8" Reducer Bushing

Remote Rod Adapter

VR8345M4302

VR8345M4302 Standard 3/4 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175˚ F (-40˚ to 79˚ C) None Two One None None None

VR8304M3509 Standard 1/2 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175˚ F (-40˚ to 79˚ C) None One One None None None

VR8304M4507 Standard 3/4 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175˚ F (-40˚ to 79˚ C) None Two One None None None

VR8305M3506 Standard 1/2 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175˚ F (-40˚ to 79˚ C) None One One One None None

VR8345K4809

VR8345K4809 Slow 3/4 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175°F(-40˚ to 79°C) None Two One None None None

VR8205H1003 Slow 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None None None None None

VR8304H4503 Slow 3/4 x 3/4 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One None None None

VR8345Q4563 VR8345Q4563 2-Stage 3/4 x 3/4 1.7 in. wc Low Fire; 3.5 in. wc High Fire

-40˚ to 175˚ F (-40˚ to 79˚ C) None Two One None None None

VR8245M2530

VR8245M2530 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) -40˚ to 175˚ F (-40˚ to 79˚ C) None None One None One None

VR8204A2076 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None

VR8204M1091 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) -40˚ to 175˚ F (-40˚ to 79˚ C) None None One One One None

VR8205A2024 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None

VR8215

VR8215S1503 Standard 1/2 x 1/2 3.5 in. wc -40˚ to 175˚ F (-40˚ to 79˚ C) None None One None None None

VR8215T1502 Slow 1/2 x 1/2 3.5 in. wc -40˚ to 175˚ F (-40˚ to 79˚ C) None None One None None None

VR8300M4406

VR8300M4406 Standard 3/4 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175°F(-40˚ to 79°C) None Two One None None None

VR8300A4508 Standard 3/4 x 3/4 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None Two One None None None

VR8300A3500 Standard 1/2 x 3/4 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None One One None None None

VR8200A2124 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) One None One One One None

VR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None

VR8200A2744 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One

+ One Elbow One None

VS820M1309

VS820M1309 Standard 3/4 x 3/4 3.5 in. wc (0.87 kPa) -40˚ to 175°F(-40˚ to 79°C) None Two One None One Yes

VS820A1054 Standard 3/4 x 3/4 3.5 in. wc (0.87 kPa) 32˚ to 175˚ F (0˚ to 79˚ C) None Two None None One None

VS820A1336 Standard 3/4 x 3/4 10.0 in. wc (2.49 kPa)

32˚ to 175˚ F (0˚ to 79˚ C) None Two None None One None

notes:All piloted valves have a 1/4" compression fitting.All the VR valves come set for natural gas, but can be converted to LP gas.The VS820A1054 is for natural gas. The VS820A1336 is for LP gas.All the VR valves have inlet and outlet pressure taps. The VS820 valves have just an outlet pressure tap.

Page 9: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

9

WW

ComPetitive RePlaCement

Universal Service Part Honeywell White-Rodgers Robertshaw

VR8345M4302

36E36-304, 36C68-423, 36H32-423

VR8304M2501

VR8304M4002, VR8304M4804

VR8305M4066, VR8305M4165, VR8305M4231 36G22-214, 36C68-423 720-051 (7200DER)

VR8345K4809

VR8304K3808 36E98-304, 36E24-214, 36E52-214 700-052

VR8205H2605, VR8305H4013, VR8305H4039,

VR8204H1006, VR8204H1055720-070 (7200IPER-S7C), 720-071 (7200IPER-S7C),

720-072 (7200IPER-S7C), 720-073 (7200IPER-LP-S7C)

VR8345Q4563 VR8205Q2381, VR8205Q2555, VR8205Q2662, VR8205Q2746, VR8205Q2787, VR8304Q4453, VR8304Q4511, VR8305Q4138, VR8305Q4146, VR8305Q4500

36C76-406, 36C76-420, 36C76-463 36D13-208, 36D13-405, 36E54-214, 36E96-314, 36G54-214

720-082 (7200IPER2-4)

VR8245M2530

VR8204A2852, VR8205M1080, VR8205M1106, VR8205M2310, VR8205M2443, VR8205M2450, VR8205M2476 36E36-304, 36E22-214 720-079 (7200IPER), 720-080 (7200IPER-LP)

722-079 (2000IPERHC)

VR8204A1201, VR8204A1219, VR8204A2001, VR8204A2035, VR8204A2043, VR8204A2175, VR8204A2183, VR8204A2241, VR8204A2225, VR8204A2803

VR8204M1075, VR8204M1232 36E01-204, 36E01-205, 36E01-206, 36E01-305, 36E93-304

VR8205A2008, VR8205A2081 36G22-214, 36J22-214 722-051 (2000DERHC), 720-051

VR8215S1503

VR8205S2262, VR8205S2270, VR8205S2296, VR8205S2338, VR8205S2353, VR8205S2361, VR8205S2379, VR8205S2395, VR8205S2437, VR8205S2858, VR8205S2882, VR8205S5802, VR8205S5828, VR8205S5836, VR8205S5844, VR8215S1222, VR8215S1263, VR8215S5207, VR8215S5215, VR8205A2008, VR8205A2016, VR8205A2024, VR8205A2065, VR8205A2081, VR8205A2131,

VR8205A2263, VR8205A2800, VR8205M1080, VR8205M1106, VR8205M1122, VR8205M1130, VR8205M1148, VR8205M1155, VR8205M1163, VR8205M2310, VR8205M2401, VR8205M2476, VR8205M2484, VR8205M2831, VR8205M2864,

VR8205M2872, VR8205M2880, VR8205M5024, VR8205M5032

36G22-214, 36J22-214, 36G22-207

VR8215T1502VR8205H1003, VR8205H1011, VR8205H2605, VR8205H2621, VR8205K1157, VR8205K1173, VR8205K2247, VR8205K2593, VR8205K2619, VR8205T5801,

VR8215T1205, VR8215T1239, VR8215T5206, VR8215T5214

VR8300M4406

VR8300A4003, VR8300A4011, VR8300A4037, VR8200A2827 VR8300A4045, VR8300A4557, VR8300A4565 36C03-400, 36C03-433 700-400

VR8300A4003, VR8300A4011, VR8300A4037, VR8300A4045, VR8300A4557, VR8300A4565 36C01-405 700-400, 720-406 (7200ER)

VR8300A3104, VR8300A3120, VR8300A3153, VR8300A3161, VR8300A3203, VR8300A3559, VR8300A3567, VR8300A3575 36C03-300, 36C03-258 720-404 (7200ER), 720-400, 720-402

VR8200A2009, VR8200A2082, VR8200A2116, VR8200A2215, VR8200A2264, VR8200A2322*, VR8200A2348

720-400 (7200ER), 720-402 (7200ER)

720-400 (7200ER), 720-402 (7200ER)

VR8200A2322*

VS820M1309

VS820A1039, VS820A1807, VS820A1815, VS820A2003, VS820A2011 36C03U-300, 36C03U-333,36C03U-400, 36C03U-433

VS820A1005, VS820A1013, VS820A1047, VS820A1260, VS820A1278, VS820A1922, VS820A5204

VS820A1120, VS820A1211, VS820A1740, VS820A1872, VS820A1898, VS820A1906

Gas Valves Selection Guide

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

*Canadian Numbers

Page 10: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

10

Honeywell SmartValve™ combines gas flow control and electronic ignition into a single unit,

providing safety and simplified wiring and appliance construction. You’ll find Honeywell

SmartValves on equipment ranging from furnaces, water heaters, boilers and rooftops to

infrared heaters, cooking units and much more.

SmartValve™ System Controls

Page 11: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

11

Q3450C1185/Q3450C2092SmartValve Pilot BurnerThe Q3450 SmartValve pilot burners provide pilot flame ignition and sensing for SmartValve

intermittent pilot systems. They consist of replaceable igniter-flame rod assembly, bracket

assembly, pilot target, ground electrode, orifice assembly, compression fitting and spring

clip. The igniter lights the pilot burner. The flame rod proves the pilot flame and the pilot

flame lights the main burner

• Used with SV9500/SV9600 SmartValve™ System.

• Replaceable Igniter-Flame Rod Assembly (Q3400A).

• Integral keyed plug provides quick, convenient connection of igniter and sensor to

SV9500/SV9600.

• Q3450 has front or 20 degree right, left flame pattern.

• Natural and LP gas orifices available.

• Variety of target styles available.

• Variety of mounting brackets available.

SmartValve™

• Family members cover the full range of opening characteristics

(slow, normal, fast) and ignition systems (hot surface, hot surface pilot)

• Universal kits include natural to LP conversion and 3⁄4" to 1⁄2" bushings

• Universal family increases service efficiency and reduces

truck and warehouse inventory

Q3400Hot Surface Pilot/Sensor AssemblyThe Q3400A Igniter-Flame Rod Assembly replaces the original igniter-flame rod

assembly in the Q3450 and Q3480 pilot hardware used with the SV9500 and

SV9600 SmartValve system. The Q3400A has a unique keyed plug connector

that will only fit the SV9500/SV9600 systems.

• Can be replaced without removing the pilot burner

• Max temp 250˚ C

• Order SKU Q3400A1024

* Diagnostic Testers Flame Current Kit #395466 Input Voltage Harness #396085

Gas

Co

ntr

ols

Page 12: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

12

SmartValve™ Control Systems Selection Guide

sPeCifiCations

Ignition/Application Universal Service Part Gas Type Opening

Characteristics

Ambient Temperature

Range

Includes

Natural to LP Conversion Kit

3/4" x 1/2" Reducer Bushings

Intermittent HSI Pilot with Combustion

Air Control and Limit Monitoring Forced Air Furnace

SV9541Q2561

Natural

2-Stage-40˚ to 175˚ F (-40˚ to 79˚ C)

Yes None

SV9641M4510 Standard Opening Yes Two

Direct Ignition, General Application

SV9510M2511

Natural

Standard Opening-40˚ to 175˚ F (-40˚ to 79˚ C)

Yes None

SV9520M2536

SV9510K2539 Slow Opening

SV9520H8513 Fast-Slow Opening0˚ to 175˚ F

(-18˚ to 79˚ C)

Intermittent HSI Pilot, General Application

SV9601M4571

Natural

Standard Opening-40˚ to 175˚ F (-40˚ to 79˚ C)

Yes

Two

SV9501M2528

NoneSV9501M8129 Fast-Fast

SV9502H2522 Slow Opening0˚ to 175˚ F

(-18˚ to 79˚ C)

SV9602P4816

Step Opening-40˚ to 175˚ F (-40˚ to 79˚ C)

None Two

SV9602P4824

SV9602P4832

SV9602P4840

Page 13: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

13

SmartValve™ Control Systems Selection Guide

sPeCifiCations CRoss-RefeRenCe

Includes

OEM Brands ReplacesExtension Harness

No

ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite

SV9540Q2464, SV9541Q3098

ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite, Mestek, Slant/Fin

SV9541M2094, SV9540M2229, SV9540M2260, SV9640M4116, SV9640M4124, SV9540M2278, SV9540M2245, SV9640M3126, SV9640M4132

No

ModineSV9510M2347, SV9510M2362, SV9410M2902, SV9510M2412, SV9510M2354,

SV9410M2910, SV9510M2388, SV9510M2420

SV9420M2331, SV9520M2403, SV9420M2323

Roberts Gordon SV9510H2228, SV9510K2133, SV9510K2158, SV9510K2141, SV9510K2166

Armstrong, Concord, AirEase SV9520H8042, SV9520H8034, SV9520H8067, SV9520H8026

No

SV9601M4167, SV9601M3003,SV9601M4225

ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite

SV9501M2056, SV9501M2080, SV9501M2718, SV9501M2726, SV9501M2031, SV9501M2049, SV9501M2239, SV9501M2700, SV9501M2734, SV9501M2742, SV9501M2064

Yes

SV9501M8103

Laars, Utica, Armstrong, Concord, AireEaseSV9501H3415, SV9501H2417, SV9501H2409, SV9502H1706, SV9502H2704, SV9501H3423,

SV9501H2425

Yes

Burnham, ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite

SV9501P2004, SV9601P4107, SV9501P2053, SV9502P2101, SV9602P4105

Burnham SV9501P2087, SV9601P4172, SV9502P2127, SV9602P4121

BurnhamSV9501P2020, SV9501P2046, SV9601P4149, SV9601P4164, SV9502P2119, SV9502P2135,

SV9602P4113, SV9602P4139

SV9601P4115

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

Page 14: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

14

Honeywell has made replacing pilots easy with their new line of universal pilot burners. Now four pilots

replace over 120 so you can finish the job on the first trip. Reduce costs and make more money with

Honeywell Universal Pilots.

Universal Pilot Burners

When selecting universal pilot burners for your next job, look for these Honeywell features:

• For use in Natural and LP applications

• Peel-N-Seal Packaging label with cross reference and

installation instructions on outside of packaging

Q314UStanding Pilot• Target-style pilot burner

• Three position adjustable

hood

Q345UIntermittent Pilot• Target-style pilot burner

• Three position adjustable

hood

Q348UIntermittent Pilot• 1" Batwing-style pilot burner

Q3451UIntermittent Pilot• Target-style pilot burner with

integral ignition lead

• Three position adjustable

hood

Page 15: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

15

Q314u1001 Cross ReferenceModel

Number Hood Hood Angle Orifice Gas Type Compression Fitting Auxiliary Bracket

Q314A3471 As Shipped As Shipped (L) Left As Shipped NAT 1/8" NoQ314A3513 As Shipped (F) Front As Shipped NAT As Shipped (1/4") YesQ314A3547 As Shipped As Shipped (L) Left As Shipped NAT As Shipped (1/4") YesQ314A3679 As Shipped As Shipped (L) Left As Shipped NAT As Shipped (1/4") NoQ314A3687 As Shipped (F) Front As Shipped NAT As Shipped (1/4") NoQ314A3703 As Shipped As Shipped (L) Left Green = BBR-10 (0.010 in.) LP As Shipped (1/4") NoQ314A3729 As Shipped (K) Right As Shipped NAT As Shipped (1/4") NoQ314A3737 As Shipped (F) Front As Shipped NAT As Shipped (1/4") NoQ314A3802 As Shipped (F) Front Green = BBR-10 (0.010 in.) LP As Shipped (1/4") NoQ314A3828 As Shipped (F) Front Green = BBR-10 (0.010 in.) LP As Shipped (1/4") NoQ314A4586 As Shipped (F) Front Check Application Check Application As Shipped (1/4") Check ApplicationQ314A6094 As Shipped As Shipped (L) Left Check Application Check Application As Shipped (1/4") Check ApplicationQ314A6102 As Shipped (K) Right Check Application Check Application As Shipped (1/4") Check ApplicationQ314A6557 As Shipped (F) Front As Shipped NAT As Shipped (1/4") NoQ314A6631 As Shipped (F) Front As Shipped NAT 1/8" NoQ314A6862 As Shipped (F) Front Check Application Check Application Check Application NoQ314A6946 As Shipped As Shipped (L) Left As Shipped NAT As Shipped (1/4") NoQ314A6953 As Shipped As Shipped (L) Left Green = BBR-10 (0.010 in.) LP As Shipped (1/4") NoQ314A6961 As Shipped (K) Right As Shipped NAT As Shipped (1/4") NoQ314A9015 As Shipped (K) Right As Shipped NAT As Shipped (1/4") YesQ314AFA As Shipped (F) Front Check Application Check Application Check Application YesQ314AFB As Shipped (F) Front Check Application Check Application Check Application NoQ314AFK As Shipped (F) Front Check Application Check Application Check Application NoQ314AKA As Shipped (K) Right Check Application Check Application Check Application YesQ314AKB As Shipped (K) Right Check Application Check Application Check Application NoQ314ALA As Shipped As Shipped (L) Left Check Application Check Application Check Application YesQ314ALB As Shipped As Shipped (L) Left Check Application Check Application Check Application NoQ314U1001 Check Application Check Application Check Application Check Application Check Application Check ApplicationQ350A1065 Low BTU Hood (F) Front Pink = CAR-12 (0.012 in.) NAT As Shipped (1/4") NoQ350A1222 Low BTU Hood (L) Left Pink = CAR-12 (0.012 in.) NAT As Shipped (1/4") NoQ350A1271 Low BTU Hood (K) Right Lt blue = CAR-13 (0.013 in.) NAT As Shipped (1/4") NoQ350A1305 Low BTU Hood (K) Right Pink = CAR-12 (0.012 in.) NAT As Shipped (1/4") NoQ350A1321 Low BTU Hood (L) Left Pink = CAR-12 (0.012 in.) NAT As Shipped (1/4") NoQ350A1545 Low BTU Hood (L) Left Pink = CAR-12 (0.012 in.) NAT As Shipped (1/4") YesQ350A1644 Low BTU Hood (L) Left Pink = CAR-12 (0.012 in.) NAT 1/8" NoQ350A1677 Low BTU Hood (L) Left Pink = CAR-12 (0.012 in.) NAT 1/8" NoQ350A1859 Low BTU Hood (K) Right Yellow = BBF-8 (0.008 in.) LP As Shipped (1/4") NoQ350A1867 Low BTU Hood (L) Left Yellow = BBF-8 (0.008 in.) LP As Shipped (1/4") YesQ350A2097 Low BTU Hood (F) Front Lt blue = CAR-13 (0.013 in.) NAT As Shipped (1/4") NoQ350A2212 Low BTU Hood (F) Front Pink = CAR-12 (0.012 in.) NAT As Shipped (1/4") NoQ350A2287 Low BTU Hood (K) Right Check Application Check Application Check Application YesQ350AFB Low BTU Hood (F) Front Check Application Check Application Check Application NoQ350AFK Low BTU Hood (F) Front Check Application Check Application Check Application NoQ350AKA Low BTU Hood (K) Right Check Application Check Application Check Application YesQ350AKB Low BTU Hood (K) Right Check Application Check Application Check Application NoQ350AKK Low BTU Hood (K) Right Check Application Check Application Check Application NoQ350ALA Low BTU Hood (L) Left Check Application Check Application Check Application YesQ350ALB Low BTU Hood (L) Left Check Application Check Application Check Application NoQ350ALK Low BTU Hood (L) Left Check Application Check Application Check Application No

Colors refer to the color of the label on the bag.

Gas

Co

ntr

ols

Scan here for installation and

product information.

Page 16: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

16

Universal Pilot Burners Cross Reference

Q345u1005 Cross ReferenceModel

Number Hood Angle: Orifice: Gas Type Compression Fitting Auxiliary Bracket

Q345A1008 As Shipped (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") NoQ345A1016 As Shipped (L) Left Gray = BBR-12 (0.012 in.) LP As Shipped (1/4") NoQ345A1024 (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") NoQ345A1065 (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") YesQ345A1156 (F) Front As Shipped NAT As Shipped (1/4") NoQ345A1305 (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") Check ApplicationQ345A1313 As Shipped (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") Check ApplicationQ345A1321 (K) Right Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") Check ApplicationQ345A1446 As Shipped (L) Left Red = BBR-11 (0.011 in.) LP As Shipped (1/4") YesQ345A1701 (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") NoQ345A1750 (F) Front Orange = BCR-18 (0.018 in.) NAT 1/8" NoQ345A1818 As Shipped (L) Left Orange = BCR-18 (0.018 in.) NAT 1/8" NoQ345A2030 As Shipped (L) Left As Shipped NAT As Shipped (1/4") NoQ345A2055 (F) Front As Shipped NAT As Shipped (1/4") NoQ345A2196 As Shipped (L) Left As Shipped NAT As Shipped (1/4") YesQ345A2360 As Shipped (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") NoQ345A2386 As Shipped (L) Left Red = BBR-11 (0.011 in.) LP As Shipped (1/4") NoQ345A2402 As Shipped (L) Left As Shipped NAT As Shipped (1/4") NoQ345A2816 As Shipped (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") NoQ345A2824 As Shipped (L) Left Gray = BBR-12 (0.012 in.) LP As Shipped (1/4") NoQ345AFA (F) Front Check Application Check Application Check Application YesQ345AFB (F) Front Check Application Check Application Check Application NoQ345AFK (F) Front Check Application Check Application Check Application NoQ345AKB (K) Right Check Application Check Application Check Application NoQ345ALA As Shipped (L) Left Check Application Check Application Check Application YesQ345ALB As Shipped (L) Left Check Application Check Application Check Application NoQ345U1005 Check Application Check Application Check Application Check Application Check Application

Q348u1009 Cross ReferenceModel

Number Orifice Gas Type Compression Fitting Auxiliary Bracket

Q348A1002 As Shipped NAT As Shipped (1/4") NoQ348A1010 Brown = KR14 (0.014 in.) LP As Shipped (1/4") NoQ348A1101 As Shipped NAT As Shipped (1/4") YesQ348A1226 Blue = A26 (0.026 in.) NAT As Shipped (1/4") NoQ348A1275 White = KF24 (0.024 in.) NAT 1/8" NoQ348A1333 As Shipped NAT 1/8" NoQ348A1341 Brown = KR14 (0.014 in.) LP 1/8" NoQ348AAA Check Application Check Application Check Application YesQ348AAB Check Application Check Application Check Application NoQ348U1009 Check Application Check Application Check Application Check Application

Colors refer to the color of the label on the bag.

Page 17: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

17

Universal Pilot Burners Cross Reference

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

Q3451u1000 Cross ReferenceModel

Number Hood Angle Orifice Gas Type Compression Fitting Igniter Lead

Q3451B1004 (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B1079 As Shipped (F) Front Purple = BCR-10 (0.010 in.) LP As Shipped (1/4") As Shipped (36" igniter)Q3451B1095 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B1103 (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B1178 (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B1186 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B1194 As Shipped (F) Front Purple = BCR-10 (0.010 in.) LP As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B1236 (L) Left Gray = BBR-12 (0.012 in.) LP As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B1244 (L) Left Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B1301 (L) Left As Shipped (BCR-20 (0.020 in)) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B1707 (L) Left Red = BBR-11 (0.011 in.) LP As Shipped (1/4") As Shipped (36" igniter)Q3451B1715 (L) Left Check Application Check Application As Shipped (1/4") As Shipped (36" igniter)Q3451B2002 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B2010 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT 1/8" As Shipped (36" igniter)Q3451B2036 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B2044 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B2077 As Shipped (F) Front As Shipped (BCR-20 (0.020 in)) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B2085 As Shipped (F) Front Gray = BBR-12 (0.012 in.) LP As Shipped (1/4") As Shipped (36" igniter)Q3451B2101 As Shipped (F) Front Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451B3018 (K) Right Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B3026 (K) Right Orange = BCR-18 (0.018 in.) NAT 1/8" As Shipped (36" igniter)Q3451B3067 (K) Right Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451B3083 (K) Right Orange = BCR-18 (0.018 in.) NAT As Shipped (1/4") As Shipped (36" igniter)Q3451BF As Shipped (F) Front Check Application Check Application Check Application Check ApplicationQ3451BK (K) Right Check Application Check Application Check Application Check ApplicationQ3451BL (L) Left Check Application Check Application Check Application Check ApplicationQ3451K2002 As Shipped (F) Front As Shipped (BCR-20 (0.020 in)) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451K2010 As Shipped (F) Front Gray = BBR-12 (0.012 in.) LP As Shipped (1/4") 55" igniter lead packed seperatelyQ3451K2028 As Shipped (F) Front As Shipped (BCR-20 (0.020 in)) NAT As Shipped (1/4") 55" igniter lead packed seperatelyQ3451KF As Shipped (F) Front Check Application Check Application Check Application Check ApplicationQ3451U1000 Check Application Check Application Check Application Check Application Check Application

Colors refer to the color of the label on the bag.

Page 18: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

18

Contractors depend on Honeywell for easy installation and reliable performance. Built for long service life,

the Honeywell Q313U, Q340A and Q390A will work for nearly all pilot generated millivolt applications.

Thermocouples/Thermopiles

Thermocouple and Thermopile Selection Guide

theRmoPiles

Lead Length (in.) Universal Direct Replacement Connection Includes

35 Q313U3000

Q313U3000

Spade Terminal

Push-In clip, PG9 adapter, 1/2" attaching nut, Split nut, spade to QC adapter

Q313A1022

Q313A1139 Push-In clip

Q313A1170 PG9 adapter

Q313A1188Push-In clip, 1/2" attaching nut,

PG9 adapter

47 Q313A1055 Q313A1055 1/2" attaching nut

When selecting a thermocouple or thermopile for your next job, look for these Honeywell features:

• Variety of lead lengths

• Easy installation

• Many accessories included

• Durability

For a complete cross-reference, visit www.customer.honeywell.com

theRmoCouPles

Lead Length (in.) Universal Tradeline

Cross-Reference

White-Rodgers Robertshaw Husky Johnson Controls

18 Q340A1066 Q390A1095 H06E-518, HO6E-18 K16BT-18 K19AT-18

24 Q340A1074 Q390A1046 H06E-524, HO6E-24 1970-24, 1980-24 K16BT-24 K19AT-24

30 Q340A1082 Q390A1053 H06E-530, HO6E-30 1970-30 K16BT-30 K19AT-30

36 Q340A1090 Q390A1061 H06E-536, HO6E-36 1970-36, 1980-36 K16BT-36 K19AT-36

48 Q340A1108 Q390A1103 H06E-548, HO6E-48 K16BT-48 K19AT-48

Page 19: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

19

Q313Replacement Thermopile• Variety of lead lengths

• Push-in clip, split nut and adapter assembly included

• Male nut connector for Pilotstat included

• Generates 750 mV in a millivolt heating system

Q340AUniversal Thermocouple• The Q340A, with a maximum amount of copel, is a

premium thermocouple with the long life and durability

that your customers demand

• Variety of lead lengths

• Push-in clip, split nut and adapter assembly included

• Male nut connector for Pilotstat included

• Generates 30 mV in standing pilot systems

Q390AThermocouple• Variety of lead lengths

• Push-in clip, split nut and adapter assembly included

• Male nut connector for Pilotstat included

• Generates 30 mV in standing pilot systems

• For situations where a utility grade thermocouple is

the best solution, the Q390A is the right choice

Gas

Co

ntr

ols

Page 20: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

20

Honeywell ignition controls have a long history of safe and reliable performance. Grow your business

while reducing inventory with Universal ignition modules. A full lineup of Universal replacement

electronic control is available for nearly all intermittent or hot surface ignition applications from

gas-fired furnaces to boilers.

Ignition Modules

When selecting ignition modules for your next job,look for these Honeywell features:

• Universal application with field adjustable timings

• Flexibility for use in single-rod or dual-rod systems

• Quality, reliability and safety of field proven controls

• Simplified installation

Page 21: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

21

S8610UUniversal Intermittent Pilot Ignition Module• Flame voltage auto-adjusts for improved operation

• Usable in both single-rod or dual-rod systems

• Field-selectable pre-purge and ignition trial timings

• Simple, diagnostic LED helps direct service effort

• Direct pilot flame current readout with standard micro-ammeter

• Plug in vent damper connection simplifies installation

• Replaces over 400 Honeywell and competitive models

Y8610UUniversal IP Retrofit Ignition System Kit• Use with 24 Vac gas-fired atmospheric furnaces,

boiler and heating appliances

• Convert standing pilot appliance to electronic ignition

• Natural or LP gas

S8910UUniversal Hot Surface Ignition Module• Easy field replacement for most hot surface ignition modules

• Single-rod or dual-rod systems

• LED diagnostics and field-adjustable ignition timings

• Natural or LP gas

• All retrofit accessories included

• Replaces over 650 Honeywell and competitive products

Gas

Co

ntr

ols

Page 22: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

22

aPPliCations timinGs

Universal Service Part Ignition System Flame

Sensor

Ignition Sequence (Note 1)

Ignition Trials To Lockout(Note 1)

Ignition Trial Time Between Trial

Time Pre-Purge

Flame Failure

Response Time

S8910U1000 Line Volt Hot Surface Ignition

1 or 2 Rods P 1 or 3

Field Selectable 4 sec. or 7 sec. Field Selectable

96 sec., 3 Trial Mode Only

32 sec. 1.5 sec.

S8610U3009 Intermittent Pilot 1 or 2 Rods C C 15 sec. or

90 sec. Field Selectable

5 Minute Delay After Failed Trial

for Ignition

0 sec. or 30 sec. Field Selectable

2.0 sec. max.

Y8610U6006 Conversion for Standing Pilot

Single Rod C C 15 sec. or

90 sec. Field Selectable

5 Minute Delay After Failed Trial

for Ignition 0 sec. 2.0 sec. max.

Y8610U4001 Conversion for Standing Pilot

Single Rod C C 15 sec. or

90 sec. Field Selectable

5 Minute Delay After Failed Trial

for Ignition 0 sec. 2.0 sec. max.

Ignition Modules Selection Guide

1. Ignition Sequence

C Continuous retry — After trial for ignition, pilot gas shuts off for five minutes, then another trial for pilot ignition takes place.

PThe number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial.

notes:

Page 23: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

23

featuRes and funCtions CRoss-RefeRenCe

Universal Service Part

Type of Gas

Ignition Source

Typical Ignition

HardwareIncludes Honeywell White-Rodgers Robertshaw Johnson

Controls

S8910U1000 Nat or LP Switched

Line Voltage

Norton 201, Norton 271, Hot Surface Elements,

Q354 Flame Rod

S89C1004, S89C1012, S89C1046, S89C1087, S89C1103, S89D1002, S89G1005, S89G1013, S89G1021, S89G1047, S89H1003, S89H1011, S89H1029, S89J1008,

S890C1007, S890D1006, S890G1003, S890G1011, S890G1029, S890G1037, S890H1002, S890H1010,

S890H1028

50E47-1 thru 50E47-79, 50E47-101 thru 50E47-179, 50E47-201 thru 50E47-279,50E47-301 thru 50E47-379,

50F47-1 thru 50F47-79,50F47-101 thru 50F47-179, 50F47-201 thru 50F47-279, 50F47-301 thru 50F47-379

HS780-17NL-104A, HS780-17NL-108A, HS780-17NL-304A, HS780-17NL-308A, HS780-17NR-104A, HS780-17NR-306A, HS780-17NR-308A, HS780-34NL-108A, HS780-34NL-304A, HS780-34NL-306A, HS780-34NL-308A, HS780-34NL-312A, HS780-34NR-104A, HS780-34NR-306A, HS780-34NR-308A, HS780-34NR-312A, HS780-34PL-308A,

S8610U3009 Nat or LP Internal Q345, Q3451,

Q3452

Integral Damper

Connector

S86 Series ,S90 Series, S8600 Series, S8610 Series, S8620 Series, S8660 Series, S8670 Series, S8680 Series

50D49-350, 50D49-360, 50D49-361, 50D50-843,

50D49-401

780-002, 780-003, 780-715, 780-735, 780-736, 780-737, 780-845, SP715, SP715A, SP735D, SP735L, USI715U,

SP735, SP750 Series

CSA42, 43, 44, 45, 46, 48, 49, G60, G65,

G67, G770 Series

Y8610U6006 Nat or LP Internal Adapter for Pilot Burner

Included

VR8304M3558 gas valve

Y8610U3003

Y8610U4001 Nat or LP Internal Adapter for Pilot Burner

Included

VR8204A2142 gas valve

aPPliCations timinGs

Universal Service Part Ignition System Flame

Sensor

Ignition Sequence (Note 1)

Ignition Trials To Lockout(Note 1)

Ignition Trial Time Between Trial

Time Pre-Purge

Flame Failure

Response Time

S8910U1000 Line Volt Hot Surface Ignition

1 or 2 Rods P 1 or 3

Field Selectable 4 sec. or 7 sec. Field Selectable

96 sec., 3 Trial Mode Only

32 sec. 1.5 sec.

S8610U3009 Intermittent Pilot 1 or 2 Rods C C 15 sec. or

90 sec. Field Selectable

5 Minute Delay After Failed Trial

for Ignition

0 sec. or 30 sec. Field Selectable

2.0 sec. max.

Y8610U6006 Conversion for Standing Pilot

Single Rod C C 15 sec. or

90 sec. Field Selectable

5 Minute Delay After Failed Trial

for Ignition 0 sec. 2.0 sec. max.

Y8610U4001 Conversion for Standing Pilot

Single Rod C C 15 sec. or

90 sec. Field Selectable

5 Minute Delay After Failed Trial

for Ignition 0 sec. 2.0 sec. max.

Ignition Modules Selection Guide

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

Page 24: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

24

Replacing a hot surface igniter can be a tricky job. Furnace designs and specifications change.

Appliance designs can be tight and difficult to maneuver in. Then there’s the need to carry a variety

of replacement parts to match the range of hot surface igniter configurations out there. Now, those

challenges have one reliable solution: Glowfly® from Honeywell.

Universal hot Surface Igniter

Six brackets. 110+ possibilities.Every Glowfly comes fully equipped with six custom mounting brackets that are optimized to replace over 110 igniter applications from nearly every furnace manufacturer without modification.

Match and mount simplicity.Simply remove the old igniter and compare it with the diagrams on Glowfly’s unique packaging guide to determine the correct mounting bracket for the job.

When selecting an igniter for your next job, look for these Honeywell features:

• Next-generation OEM silicon nitride quality for any installation

• Custom designed bracketing for universal installation

• The strongest warranty in the industry

• Avoid being caught unprepared with the unique truck-ready six-pack

• Graphic instructions provide for quick and accurate bracket selection

and installation

Page 25: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

25

Q3200U2002Six Pack

Q3200U1004Single Pack

manufaCtuReR oem # Q3200u bRaCketb

American Road Equip. 201W A

Arco Air1096048

D1380680

Armstrong Air 38322B001 A

Carrier/Bryant/Payne

LH33ZS001

B or Ec

LH33ZS001ALH33ZS002

LH33ZS002ALH33ZS003

LH33ZS003ALH33ZS004

Claire Bros.C-238

AC242

Coleman1474-051

A1474-052

Comfort Maker 1096048 DDetroit Radiant 201D ADMO Ind. 20834 ADornback Furnace 271W ADucane 20015201 BEnero Tech 10399 A

Evcon1474-051

A1474-052

Evcon Coleman 025-32625-000 B

GoodmanB1401009 DB1401018 C

B1401018S DHB Smith 50018 AHeil 1096048 DHupp Industries 09050 A

Intercity1009604

D1096048

Majestic75-92-104

A75-92-105

Metzger201N

A201W

manufaCtuReR oem # Q3200u bRaCketb

Modine 5H76032A C

Mor-Flo3200618 A

511-330-193 B

Nordyne105141000

A632-0770632-0880

Norton/St Gobain

201B

271201D

A

201K201L201N201R201W271N

271NM D271P

A271W

Raypak 600915 BRheem 62-22441-01 A

Roberts Gordon90434300 B90436600 A

Robertshaw

41-402 A41-403 B41-404 B41-405 A41-407 B41-408 A41-409 B41-410 A41-412 D41-418 C

Snyder General1380654

B13806721380680

Superior Fireplace 94851 A

manufaCtuReR oem # Q3200u bRaCketb

Tempstar 1096048 D

Trane

340039P01 AB138196P01 BB144676P01 AB144676P02 BB340039P01 A

IGN23 AIGN26 BIGN30 BIGN34 A

Viessman 9302-094 A

Wayne Home Equip.62821-001

A62821-002

Weil McLain511-330-139

B511-330-190511-330-193

White LB 120-07549 A

White-Rodgers

767A-301 A767A-303 F767A-306

A767A-311767A-350767A-353 F767A-354 A767A-357 F767A-361

A767A-364767A-366767A-370 B767A-371 A767A-372 A767A-373 D767A-376 B767A-377 A767A-382 B

Williamson 9050 A

York

025-27766-000

A025-27774-000025-29043-000025-29050-000

Igniter Bracket Replacement Cross Referencea

a Table data is correct to the best of Honeywell’s knowledge as of this publication’s date. However, some appliances may have igniter applications that are beyond the capabilities of this kit.

b For igniters that require bracket A, use the template to determine the tab to be removed.c For Carrier sealed combustion furnaces, you must use bracket E and retain the existing orange gasket for use with bracket E.

Gas

Co

ntr

ols

For a complete cross-reference, visit www.customer.honeywell.com

Scan here for installation and

product information.

Page 26: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

26

Replaces all others. The new universal platform that will not only integrate control of all combustion

blower and circulating an operations in a gas warm air appliance but also replace most ST9120,

ST9141 and ST9160 fan timer boards. Save room on your truck or on your shelves with a supply of

ST9120U1011 timers and know you’re covered.

Universal Electronic Fan Timer

When selecting fan timers for your next job, look for these Honeywell features:

• Universal application

• Easy installation

• Quality construction for long service life

ST9120U1011

• Replaces 44 existing Honeywell controls to reduce

inventory

• Integrates control of all combustion blower and

circulating fan operations in a gas warm-air appliance

• Replaceable fuse

• DIP switch selectable heat and cool delay on and

off times

• Diagnostic LED

• EAC and HUM convenience terminal connections

and continuous low speed indoor air circulation

are provided

st9120u RePlaCes oveR 44 eXistinG models

ST9101A1006 ST9120C3018 ST9120G4038 ST9160B1001

ST9101A1014 ST9120C4008 ST9120U1003 ST9160B1019

ST9101A1022 ST9120C4016 ST9141A1002 ST9160B1027

ST9120A2004 ST9120C4040 ST9141A1028 ST9160B1035

ST9120B1005 ST9120C4057 ST9141B1001 ST9160B1043

ST9120C1012 ST9120C5005 ST9150A1003 ST9160B1050

ST9120C1020 ST9120C5013 ST9150B2000 ST9160B1068

ST9120C2002 ST9120D3009 ST9150B2018 ST9160B1076

ST9120C2010 ST9120G2024 ST9150B2026 ST9160B1084

ST9120C2028 ST9120G2032 ST9150B2034 ST9160C1000

ST9120C3000 ST9120G4004 ST9160A1002 ST9160C1018

Page 27: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

27

Universal Electronic Fan Timer OEM Replacement Guide

ReCommended diP switCh settinG

Replaced Control Model Number Original OEM Appliance 1 2 3 4 5

ST9101A1006 Rheem off off off off off

ST9101A1014 Rheem off off off off off

ST9101A1022 Trade off off off off off

ST9120A1006 Armstrong off off off off off

ST9120A2004 Armstrong on off on off off

ST9120B1005 Ducane off on off off off

ST9120C1012 Snyder General on off off off off

ST9120C1020 Nordyne on off off off off

ST9120C2002 York off off off off off

ST9120C2010 Ducane off off off off off

ST9120C2028 Armstrong off off off off on

ST9120C3000 ICP off off on on off

ST9120C3018 Bard on off off off on

ST9120C4008 ICP off off on on off

ST9120C4016 ICP off off on on off

ST9120C4040 ICP off off on on off

ST9120C4057 ICP off off on on off

ST9120C5005 ICP off off on off off

ST9120C5013 ICP off off on off off

ST9120D3009 Goodman off off on off on

ST9120G2008 ICP on off off on off

ST9120G2016 ICP off off off on off

ST9120G2024 Skymark off on off on off

ST9120G2032 Skymark off on off off on

ST9120G4004 ICP off off on on off

ST9120G4012 ICP off off on on off

ST9120G4038 Trade off off on on off

ST9120U1003 Trade off off on off off

ST9141A1002 Consolidated Industries off off on off on

ST9160B1035 off off off off off

ST9160B1068 Armstrong on off off off on

ST9160B1076 Ducane off off off off off

ST9160B1084 ICP off off on off on

ST9120U Factory Default Setting off off off off off

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

Page 28: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

28

The Honeywell Hot Surface Ignition Universal Integrated Furnace Control offers universal

compatibility and remote monitoring and diagnostics. Able to replace a large number of furnace

controls in single-stage heating and cooling appliances. Honeywell UIFCs are the only controls

you need for residential natural or liquid propane fueled furnaces.

Universal Integrated Furnace Control

When selecting furnace controls for your next job, look for these Honeywell features:

• Replaces over 195 furnace controls

• Complete set of wiring harnesses for universal compatibility, simplified

installation and field-adjustable timings

• LED indicators provide system status, performance and diagnostic information

• EnviraCOM™ communications enabled

Page 29: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

29

s9200u1000 RePlaCes these inteGRated fuRnaCe ContRols

Amana/Goodman 10207704, 10207706, 10207714, 10207719, 102077-02, 102077-03, 102077-04, 102077-09, 102077-19, 1809913, 10207701, 10207702, 10207703, 10207710, B1809913, B18099-13

ICM ICM280ICP 1010806, 1380686, 1380698, 1380699, 1380-686, 1380-699Lennox X445901, 1214201

Nordyne 624591, 624557, 624564, 624628, 902378, 902696, 903106, 6245570, 6245640, 6246310, 624557-0, 624591A, 624591-A, 624591-B, 624591-C, 624591-D, 624628-0, 624631-0, 624631A, 624631-A, 624631-B, 710128A, CAR903106

Other Manufacturers 350486, 8068142, 8068561, 8068563, 10334901, 99958174, 99958175, X13120666010Rheem/Robertshaw 62-24268-01, 62-24268-02, 62-24268-03, 695-200Texas Instruments 41F-5, 61F3, 6DT-1, 6DT-2

Trane CNT03740, CNT1309, CNT1616, CNT1848, CNT1849, CNT2181, CNT2182, CNT2183, CNT2789, D340790P01, D341122P01, D330927P01, D330930P01, D330934P01, D340035P01, D340354P01, D340774P01, D341235P01

United Technologies 1012-83-9336AHSC1, 1012-83-9337A, 1012-83-9651B, 1012-925A, 1012-925B, 1012-925C, 1012933D, 1012-933D, 1012955A, 1012-955A

White-Rodgers

50A50-130, 50A50-131, 50A50-208, 50A50-210, 50A50-215, 50A50-216, 50A50-229, 50A50-240, 50A50-245, 50A50-298, 50A50-407, 50A50-472, 50A50-475, 50A55-245, 50A55-250, 50A55-288-05, 50A50-110, 50A50-111, 50A50-112, 50A50-113, 50A50-142, 50A50-143, 50A50-205, 50A50-206, 50A50-207, 50A50-209, 50A50-230, 50A50-241, 50A50-285, 50A50-286, 50A50-288, 50A50-295, 50A50-296, 50A50-405, 50A50-406, 50A50-408, 50A50-438, 50A50-471, 50A50-473, 50A50-474, 50A50-571, 50A55-120, 50A55-143, 50A55-241, 50A55-285, 50A55-286, 50A55-288, 50A55-438, 50A55-474, 50A55-571, 50A55-843, 50T35730, 50T35-730, 50T35743, 50T35-743

York

3101250000, 5253733900, 43101972100, 52537074000, 52537077000, 031.01234.000, 031-00662000, 031-01250-700, 031-01266-700, 031-01267-00, 331-09167-000, 431-01972-100, 31011140002, 031-00662, 031-00662, 031-00662-000, 031-00662-700, 031-01140-000, 031-01140-001, 031-01140-002, 031-01140-701, 031-01140-702, 031-01234-700, 031-01235-000, 031-01235-700, 031-01250-000, 031-01266-000, 031-01267-000, 031-01267-001, 031-01267-001A, 031-01284-000, 031-01933-000, 031-01972-000, 031-01973-000, 031-02166-000, 031-09166-000, 031-09167-000, 331-01933-000, 331-01972-200, CAR03101973000, CAR33101972200, CAR50A55843, G951ADB1401, G951ADB1401C, G951ADB-1401C, G951ADB1402, G951ADB-1402, G951AEB-1403, P03101267001, P031-01267-001, PTH031011400-00

HSI Universal Integrated Furnace Control• Complete set of wiring harnesses for universal compatibility

and simplified installation allowing for direct replacement of

competitive boards

• LED indicators provide system status, performance and

diagnostic information

• EnviraCOM™-enabled for easy setup of local or remote monitoring

and diagnostic systems

• Ready for remote services, whether you’re replacing old controls

or installing new equipment like the VisionPRO™ IAQ, Telephone

Access Module or EnviraZONE™

• Engineered for reliability and long-term performance

Gas

Co

ntr

ols

For a complete cross-reference, visit www.customer.honeywell.com

Page 30: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

30

sku haRness field settinGs ReCommendation safety time settinGsSW1 SW2 SW3 SW4 SW1 SW2

aman

a/Go

odm

an ¹

1809913, B1809913, B18099-13 Main Connector - E Inducer & HSI Connector - F

ON OFF

60/90/120/180 60/90/120/180

OFF

ON10207701

Inducer & HSI Connector - G

ON OFF10207702

10207703

1020770460/90/120/180 60/90/120/180 OFF

10207706

10207710 ON OFF ON

10207714

60/90/120/180 60/90/120/180 OFF

10207719

102077-02

102077-03

102077-04

102077-09

102077-19

iCm ICM280 Main Harness E & Inducer/HSI Harness F Check Control Field Settings Check Control Safety Timings

iCP

1010806

Inducer/HSI Harness A ON OFF 60/90/120/180 OFF

OFF

1380686 ON

1380698OFF

1380699

1380-686ON

1380-699

lenn

ox 1214201Inducer/HSI Harness A ON OFF

ON OFFOFF OFF

X445901 60/90/120/180 60/90/120/180

nord

yne

624557

Main Harness D & Inducer/HSI Harness B ON OFF 60/90/120/180 60/90/120/180 ON OFF

624564

624591

624628

902378

902696

903106

6245570

6245640

6246310

624557-0

624591A

624591-A

624591-B

624591-C

624591-D

624628-0

624631-0

624631A

624631-A

624631-B

710128A

CAR9031061 Wiring harness G should be used if the control being replaced has a 2-pin inducer/igniter connector instead of a 4-pin inducer/igniter connector.

Universal Integrated Furnace Control Selection Guide

Use with only 120 VAC Appliances

Page 31: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

31

Universal Integrated Furnace Control Selection Guide

sku haRness field settinGs ReCommendation safety time settinGsSW1 SW2 SW3 SW4 SW1 SW2

othe

r man

ufac

ture

rs 350486

Inducer & HSI Connector - A ON OFF 60/90/120/180 60/90/120/180 OFF OFF

806814280685618068563103349019995817499958175

X13120666010

Rhee

m/R

ober

t sha

w 62-24268-01

Main Connector - D Inducer & HSI Connector - C ON OFF 60/90/120/180 60/90/120/180 ON ON

62-24268-02

62-24268-03

695-200

texa

s in

stru

men

ts

41F-5

Main Connector - E Inducer & HSI Connector - F

ON OFF 60/90/120/180 60/90/120/180 OFF ON

50T3573050T35-73050T3574350T35-743

61F3Inducer/HSI Harness A6DT-1

6DT-2

tran

e

CNT03740Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

ON OFF

60/90/120/180 60/90/120/180OFF

OFF

CNT1309 Inducer & HIS Connector - G

Check Settings ON ON

CNT1616

Inducer & HSI Connector - AAdd jumper on harness connector

(Roll-out switch)

CNT1848CNT1849CNT2181CNT2182CNT2183CNT2789

D330927P01 ON

OFF

OFFD330930P01

OFF OND330934P01D340035P01D340354P01D340774P01D340790P01

Check Settings ONOFFD341122P01

D341235P01 ON OFF ON OFF

unite

d te

chno

logi

es

1012-83-9336AHSC1Main Connector - E

Inducer & HSI Connector - F

ON OFF

ON OFFOFF

ON

1012-83-9337A1012-83-9651B

60/90/120/180 60/90/120/1801012-925A Inducer & HSI Connector - A

ON1012-925B

Main Connector - D Inducer & HSI Connector - C

1012-925C1012933D

ON OFF OFF1012-933D1012955A Main Connector - E

Inducer & HSI Connector - F 60/90/120/180 60/90/120/180 ON OFF1012-955A

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

Page 32: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

32

Universal Integrated Furnace Control Selection Guide

sku haRness field settinGs ReCommendation safety time settinGsSW1 SW2 SW3 SW4 SW1 SW2

whi

te-R

odge

rs

50A50-110

Inducer & HSI Connector - A

ON

OFF60/90/120/180 60/90/120/180

OFF

ON50A50-111

50A50-11250A50-11350A50-130

OFF50A50-13150A50-14250A50-143 Check Settings

ON50A50-205

OFF

ON OFF50A50-20650A50-207 Inducer & HSI Connector - G50A50-208

Inducer & HSI Connector - A

60/90/120/180 60/90/120/180 OFF50A50-209 ON ON ON50A50-210

60/90/120/180 60/90/120/180OFF

50A50-215

50A50-216

50A50-229

50A50-230

50A50-240

50A50-241

50A50-24550A50-285 Inducer & HSI Connector - G OFF ON OFF50A50-286 Inducer & HSI Connector - A

ON

60/90/120/180 60/90/120/180

ON50A50-288

Inducer & HSI Connector - GON OFF

50A50-29550A50-296

60/90/120/180 60/90/120/180

50A50-298 OFF50A50-405 Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

OFF ON50A50-406

50A50-407Inducer & HSI Connector - A

ONOFF

50A50-408

ON50A50-438 Check Settings ON

50A50-471Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

OFF OFF

50A50-472 Inducer & HSI Connector - A Check Settings ON OFF

50A50-473Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

OFF

OFF

ON

50A50-474Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

50A50-475 Inducer & HSI Connector - A

ONOFF

50A50-571Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

50A55-120

Inducer & HSI Connector - A

OFF ON OFF50A55-143

ON

30/60 60/90/120/180 60/90/120/18050A55-241

OFF

ON ON ON50A55-245

60/90/120/180 60/90/120/180

OFF50A55-25050A55-28550A55-286 ON50A55-288

Inducer & HSI Connector - G

OFF

50A55-288-0550A55-438 Inducer & HSI Connector - A

Add jumper on harness connector (Roll-out switch)

Check Settings50A55-474

OFF ON OFF50A55-571

50A55-843 - universal Inducer & HSI Connector - A Check Settings Check Settings 60/90/120/180 60/90/120/180

Use with only 120 VAC Appliances

Page 33: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

33

Universal Integrated Furnace Control Selection Guide

For a complete cross-reference, visit www.customer.honeywell.com

Gas

Co

ntr

ols

sku haRness field settinGs ReCommendation safety time settinGsSW1 SW2 SW3 SW4 SW1 SW2

york

3101250000

Inducer & HSI Connector - A ON OFF 60/90/120/180 60/90/120/180 OFF

OFF5253733900

31011140002ON

43101972100

52537074000OFF

52537077000

031.01234.000 ON

031-00662 OFF

031-00662

ON

031-00662000

031-00662-000

031-00662-700

031-01140-000

031-01140-001

031-01140-002

031-01140-701

031-01140-702

031-01234-700

031-01235-000

031-01235-700

031-01250-000

031-01250-700 OFF

031-01266-000 ON

031-01266-700 OFF

031-01267-00

ON

031-01267-000

031-01267-001

031-01267-001A

031-01284-000

031-01933-000

031-01972-000

031-01973-000

031-02166-000

031-09166-000

031-09167-000

331-01933-000

331-01972-200

331-09167-000

431-01972-100

CAR03101973000

CAR33101972200

CAR50A55843

G951ADB1401

G951ADB1401C

G951ADB-1401C

G951ADB1402

G951ADB-1402

G951AEB-1403

P03101267001

P031-01267-001

PTH031011400-00

Page 34: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

34

Honeywell fan and limits combines high temperature limit with circulating blower control. As an

industry standard for many years, these controls have a large and varied installed base. You’ll find

Honeywell fan and limits on a wide range of furnace equipment. Our universal family increases

service efficiency and reduces truck and warehouse inventory.

Fan and Limit Controls

Key features for the family of universal fan and limits:

• Family members cover the full range of insertion — 5", 8", 11-1/2"

• Adjustment tool and cross-reference allow for field adjustment to factory settings

• Universal kit accessories reduce inventory

L4064High Limit and Fan Controller• Used in all types of forced-air heating systems

• Three wiring terminal options available for easy installation

• Available in a variety of fan and high-limit setting ranges

• Controls adapt to many competitive mounting holes

in replacement applications

• Push-in receptacles for stripped wire

• L4064 models for timed fan on

• Special high temperature limit models available

• Suitable for line voltage, low voltage or

millivoltage control applications

Page 35: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

35

model os# ReGionelement

inseRtion lenGth (in.)

RePlaCeshiGh limit stoP

fan-on stoP

fan-off stoP

manual fan

button

manual Reset

switChinG aCtion

L4064

L4064B2228 US/Canada 5

L4064A1339, L4064A1503L4064A1586, L4064A2402L4064A2659, L4064A2980 L4064B1469, L4064B1683 L4064B2228, L4064B2640 L4064B2657, L4064B2681 L4064B2889, L4064B2897 L4064B2947, L4064B3010 L4064B3143, L4064B3143 L4064B3374, L4064B3432 L4064B3440, L4064B3473 L4064B3598, L4064E1983 L4064E2437, L4064E2544

L4064L1046

200°F 97°C

125°F 52°C

100°F 38°C Yes No

Fan: SPST — N.O. (make on rise), Limit: SPST —

N.C. (break on rise)

L4064R1159 US/Canada 5

L4064E1835, L4064E2551 L4064L1145, L4064R1043 L4064R1050, L4064R1159

250°F 121°C

125°F 52°C

100°F 38°C Yes No

Fan: SPST — N.O. (make on rise), Limit: SPST —

N.C. (break on rise)

L4064B2236 US/Canada 8

L4064A1347, L4064A1511 L4064A1719, L4064A1735 L4064A2030, L4064A2279 L4064A2998, L4064B1618 L4064B2236, L4064B2608 L4064B2772, L4064B2822 L4064B2905, L4064B2905 L4064B2962, L4064B3051 L4064B3085, L4064B3325 L4064B3333, L4064B3341 L4064B3366, L4064B3457 L4064B3499, L4064B3572 L4064E1777, L4064E2163 L4064E2171, L4064E2452 L4064E2502, L4064E2684 L4064F1023, L4064F1031 L4064F1080, L4064F1098 L4064L1004, L4064A2774

200°F 97°C

125°F 52°C

100°F 38°C Yes No

Fan: SPST — N.O. (make on rise), Limit: SPST —

N.C. (break on rise)

L4064R1142 US/Canada 8

L4064A2469, L4064B1691 L4064B2616, L4064B2806 L4064B2814, L4064B2830 L4064B3390, L4064B3481 L4064B3507, L4064R1019, L4064R1118, L4064R1126,

L4064R1142

250°F 121°C

125°F 52°C

100°F 38°C Yes No

Fan: SPST — N.O. (make on rise), Limit: SPST —

N.C. (break on rise)

L4064B2210 US/Canada 11.5

L4064A1321, L4064A1453 L4064A2758, L4064A3012 L4064A3020, L4064A3038 L4064A3046, L4064B1451 L4064B1592, L4064B1717 L4064B1725, L4064B1931 L4064B2210, L4064B2723 L4064B2749, L4064B2848 L4064B2954, L4064B3036 L4064B3044, L4064B3077 L4064B3184, L4064B3465 L4064B3580, L4064E2056 L4064E2114, L4064E2130

L4064E2155

200°F 97°C

125°F 52°C

100°F 38°C Yes No

Fan: SPST — N.O. (make on rise), Limit: SPST —

N.C. (break on rise)

L4064R1134 US/Canada 11.5

L4064A2972, L4064B2756 L4064J1008, L4064K1006 L4064L1129, L4064N1074L4064R1027, L4064R1035L4064R1068, L4064R1134

L4064R1167

250°F 121°C

125°F 52°C

100°F 38°C Yes No

Fan: SPST — N.O. (make on rise), Limit: SPST —

N.C. (break on rise)

For a complete cross-reference, visit www.customer.honeywell.com

* Fan On and Fan Off may need to be adjusted.

Fan and Limits Selection Guide

Gas

Co

ntr

ols

Page 36: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

36

Honeywell has set the standard for oil-fired furnaces, boilers and water heaters when it comes to oil

primary controls. In addition to delivering dependability and high quality products, Honeywell has

gone one step further to create an easy-to-use oil primary control designed to simplify installation

and enhance maintenance. Our latest innovation will redefine that standard as the next generation of

controls proves, it takes a legend to make one.

Oil Primaries

When selecting an oil primary for your next job, look for theseHoneywell features:

• Universal application with field adjustable timings

• Integrated display allows for setup without using and external tool

• Advanced diagnostics that direct the technician to the likely cause of ignition failure

• Legendary performance and reliability

Page 37: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

37

R8184Protectorelay® Oil Burner Control• Industry-standard intermittent ignition control

• Solid-state, flame-sensing circuit

• 45-second timing, safety switch

• Mounts on standard 4" x 4" junction box

• External button to manually reset safety switch after lockout

W8735S3000EnviraCOM™ Alarm Module• Works with any alarm generating EnviraCOM enabled control

• Local LED alarm present and communication active indication

• Simple low-voltage, 5-wire installation

R8182Combination Protectorelay® and Hydronic Heating Controllers• Immersion-type Aquastat® controller and oil burner primary control

• Provides high limit and low limit/circulator control

• Use in intermittent ignition applications

• Circulator zone control with ZC and ZR terminals on R8182D, E, H, J

R7284U1004Universal Digital Electronic Oil Primary• A single part number for nearly all applications helps reduce inventory cost

• 16 character two line tri-lingual display provides simple programming

and diagnostics

• No additional tool to purchase to take advantage of all control features

• Monitors igniter and cad cell and alerts technician what component

caused ignition failure

• Error history and baseline readings provide system performance trends

Oil/

Hyd

ron

ic C

on

tro

ls

Scan here for installation and

product information.

Page 38: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

38

oil PRimaRies

Specifications

Ignition Type Universal Service Part Lockout Time (sec.)

Valve On Delay (sec.)

Blower Off Delay (min.)

Alarm Contacts

Manual Trip Lever w/ LED Indicator

Interrupted R7284U1004

15

0/15 0/2/4/6

Yes*Yes

15

15 0.25

300/15 0/2/4/6

No

450/15 0/2/4/6 Yes* No

Intermittent R7284U1004

15 Yes*

30

45 Yes

Yes*

R8184M1051 45

Oil Primaries Selection Guide

(1) Includes 40 VA transformers and heat/cool thermostat connections for warm-air furnace applications.*Alarm accessory module required. EnviraCOM™ Alarm Module W8735S3000

R8182 Combination aQuastat and oil PRimaRy

Direct Service Part

Features and Functions

Includes

Upgraded Cross-Reference

MountingDifferential Temperature (˚F)

HoneywellHigh Limit Low Limit/

Circulator

R8182D1079 Vertical 10 fixed 10 to 25 Heat-Conductive Compound R8182E1118

R8182D1111 Horizontal 10 fixed 10 to 25 Heat-Conductive Compound R8182D1129

R8182H1070 J Box 10 fixed 10 to 25 Heat-Conductive Compound

R8182J1042 J Box 15 fixed Heat-Conductive Compound R8182J1059

staCk switChes

Model Number Ignition Type Replaces

RA116A1055 Intermittent RA116A1063

RA117A1047 Interrupted

Page 39: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

39

Oil Primaries Selection Guide

Cross-Reference

Ignition Type Universal Service Part Honeywell Beckett Carlin White-Rodgers

Interrupted R7284U1004

R7184U1004, R7184P1031, R7184P1049, R7184P1056, R7184P1064, R7184P1072

7505P125M

50200-02S, 602000-02S,

6020002S015120, 6020002S030015, 6020002S030030, 6020002S030120, 6020002S030300, 6020002S030010

R7184A1026, R7184A1075, R7184A1000 7505A0000 40200-02S 669-640,669-670

R7184B1024, R7184B1032, R7184B1016 7505B1500

R7184P1080, R7184P1098 7505P1515

R7184U1012

R7184A1018, R7184A1034 42230-02S 669-440, 669-445, 669-470, 669-540

R7184U1020

R7184A1042

Intermittent R7284U1004

R8184G1294, R8184G1302, R8184G4066, R8184G4074, R8184G4033, R8184G4090, R8184G1427, R8184G4058

7505A0000 668-601, 668-670

R8184G1393, R8184G1302, R8184G4074, R8184G4033 668-501

R8184G1286, R8184G1427, R8184G1458, R8184G4009, R8184G4025, R8184G4082, R8184G4108

48245-S 668-401, 668-415, 668-430, 668-515

668-430

R8184M1051 R8184M1002 668-441, 668-451, 668-454

For a complete cross-reference, visit www.customer.honeywell.com

Cad Cell seleCtoR Guide

Product Number

CAD Cells (1)

Lead Length

(in.)

Wire Termination

Mounting Bracket Includes Tradeline

Value Replaces White-Rodgers Westwood

C554A1463 130367 60 2 Flag 1/4" QC Type R

A, B, E, J and P Mounting Brackets

and Fuel Line Adaptor

Super Tradeline

C554A1307, C554A1315, C554A1398, C554A1133, C554A1174, C554A1372, C554C1570, C554A1216, C554A1927, C554A1794

956-154 TMK-60

C554A1794 130367 60 Stripped Type RE Mounting Bracket

and Fuel Line Adaptor

Tradeline C554A1307, C554A1927956-11956-154

TMK-60

notes:*120320 replacement CAD cell 7.5 MA minimum sensitivity at 2' candles.*130367 high-sensitivity CAD cell 12 MA minimum sensitivity at 2' candles.

Oil/

Hyd

ron

ic C

on

tro

ls

Page 40: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

40

The AquaReset improves comfort and efficiency inside because it knows the weather outside. Our new

product is designed to help homeowners save on energy costs by operating their boiler at more efficient

settings based on the actual outdoor temperature while providing the necessary heat to maintain a

comfortable indoor temperature. Integrating easily into any Honeywell outdoor reset ready electronic

Aquastat, this product provides easy installation and up to 15 percent* energy savings for the homeowner.

Outdoor Reset

*Honeywell Inc. 1979 Study; Control Systems Providing Energy Savings with single and multi-zone Hydronic Heating. 15% is the average energy savings and can only be achieved when installing an outdoor reset model, domestic hot water priority is off and the unit is installed as directed.

Page 41: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

41

W8735Y1000Honeywell AquaReset Wireless Outdoor Reset Kit• Upsell opportunity for contractors during a new boiler installation

when an Outdoor Reset Ready Aquastat (L7224/L7248) is present

• Improves boiler efficiency by resetting the boiler water temperature

based on the outdoor temperature

• Quick and easy install thanks to RedLINK™ wireless communication

• Compatible with any L7224/L7248 Outdoor Reset Ready Aquastat,

S9361A Integrated Boiler Control, and R7910 SOLA Controls

• Kit includes Wireless AquaReset module (W8735ER1000) and

wireless sensor (C7089R1013)

W8735S1000Honeywell AquaReset Outdoor Reset Kit• Designed to improve boiler efficiency by automatically resetting boiler

water temperature based on outdoor temperature

• Upsell opportunity for contractors during a new boiler installation when

an Outdoor Reset Ready Aquastat is present

• Simple installation with three wire connection to the Aquastat

• Compatible with any L7224/L7248 Outdoor Reset Ready Aquastat,

S9361A Integrated Boiler Control, and R7910 SOLA Controls

W8735S1008Honeywell AquaReset Domestic Hot Water KitRequired for domestic hot water override with some Honeywell

AquaReset installations*

• Compatible with Honeywell AquaReset wired and wireless kits

• Ensures domestic hot water needs are met when combining

AquaReset with an indirect DHW tank.

• Easy three-wire installation to AquaReset module

* Kit required to enable domestic hot water override functionality with Indirect DHW tank when the Zr terminal on the Aquastat® is not used or available for DHW demand. See instructions or visit customer.honeywell.com for complete details.

Oil/

Hyd

ron

ic C

on

tro

ls

Page 42: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

42

The boiler industry standard, Honeywell Aquastats have a proven track record, wide OEM new

equipment usage and a large installed base. Our electronic Aquastat family builds on this reputation

while adding performance-enhancing features. Honeywell service parts have you covered, offering

universal compatibility and improved service call efficiency — while keeping both distributor and

contractor satisfaction in mind.

Aquastats®

When selecting an Aquastat for your next job, look for these Honeywell features:

• Enhanced to comply with 2012 Department of Energy Standards

• Broad range and flexibility covers a variety of applications and needs

• Universal versions allow multiple mounting and configuration capability

• Universal versions reduce inventory and assure truck availability

• Electronic versions include communications as a standard feature,

allowing add-on efficiency, troubleshooting and monitoring capability

• EnviraCOM™ communications enabled

Page 43: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

43

L6006/L4006Aquastat Controller• Totally enclosed Micro Switch snap-acting switches operate on

temperature rise to setpoint

• Visible control point scale and external adjustment screw permit easy setting

• Horizontal or vertical insertion of sensing element

• Direct or well immersion of the sensing element

• SPST and SPDT switching action

L6008/L4008Aquastat Controller• Visible control point scale and external adjustment screw permit easy setting

• Horizontal or vertical mounting of the remote element into boiler,

tank or other container

• Fast-responding remote temperature sensor

• SPDT or SPST switching action

L8124/L8148Triple Aquastat Relay• Oil and gas versions

• High-limit or high-and-low-limit versions

• Mounts directly on boiler horizontally or vertically

• Provides multizone control

• Immersion-type controllers that combine high limit protection with

low limit and circulator control in forced hydronic heating systems

• The L8148 includes a transformer to provide power for the

low-voltage control circuit

• Gas versions include a transformer to provide power for the low voltage circuit

L7224Universal Oil Electronic Aquastat• Complies with 2012 Department of Energy Standards

• Diagnostic updates through easy-to-read LED displays

• +/- 2˚ F accuracy and faster response times

• Adjustable high- and low-limit differential

• Outdoor reset functionality available with W8735S1000 and W8735Y1000

• Provides multizone control

• Thermowell horizontal or vertical and flush mounting

• EnviraCOM™ communications enabled

• Compatible with W8735S3000 Alarm Module

Oil/

Hyd

ron

ic C

on

tro

ls

SIN

GL

E-F

UN

CT

ION

MU

LT

I-

FU

NC

TI

ON

Page 44: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

44

Single-Function Aquastat® Selection Guide

All mounting is universal horizontal or vertical mounting unless noted. All Tradeline Aquastats® include heat-conductive compound.1 Product Numbering 400X=SPST, 600X=SPDT X006=Thermowell Sense, X008=Remote Sense A Break on Rise B Make on Rise D Break on Rise w/o Cover E Break on Rise w/Manual Reset G Two SPDT H Make on Rise w/Strap-On Mount

2 Capillary Length If less then 3" then insulation depth of thermowell3 All manual reset models comply with the CSD-1 requirement for Manual Reset. Devices with

maximum Range of 200°F, 190°F 180°F are designed to meet local code requirements regarding maximum setpoints. Units having scale ranges above 240°F do not comply with ASME Section IV for boilers, use 240 Maximum range Aquastats.

4 Electrical Ratings A Millivolt: 0.25 A @ 0.25 to 12 Vdc; AFL: 8 A @ 120 Vac/5.1 A @ 240 Vac ALR: 48 A @ 120 Vac/30.6 A @ 240 Vac D Millivolt: 0.25 A @ 0.25 to 12 Vdc; AFL: 1.3 A @ 240 Vac/8 A @ 120 Vac; ALR: 48 A @ 120 Vac/30.6 A @ 240 Vac B AFL: 2.6 A @ 120 Vac/1.3 A @ 240 Vac; ALR: 15.6 A @ 120 Vac/7.8 A @ 240 Vac H AFL: 8 A @ 120 Vac/1.3 A @ 240 Vac; ALR: 48 A @ 120 Vac/30.6 A @ 240 Vac

sensoR and theRmowell featuRes and funCtions

Product Number1 Switch Configuration

Thermowell Included

Thermowell Spud Size —

14 NPT (in.)

Capillary Length (in.)2

Manual Reset

Operating Temperature Range

(˚F)

Factory Stop (˚F)

Differential Temperature

(˚F)

Electrical Ratings4

L4006A1009

SPST - N.C. (break on rise)

Yes 1/2 1-1/2 100 to 240 5 Fixed A

L4006A1017 Yes 1/2 1-1/2 100 to 240 5 to 30 A

L4006A1132 Yes 3/4 3 100 to 240 160 5 Fixed A

L4006A1678 3 100 to 240 5 to 30 A

L4006A1959 3 40 to 180 2 Fixed B

L4006A1967 Yes 1/2 1-1/2 100 to 2403 5 to 30 A

L4006A2007 3 100 to 240 5 to 30 A

L4006A2148 3 100 to 200 5 to 30 A

L4006E1042 Yes 130 to 2703 240 A

L4006E1067 3 Yes 130 to 270 A

L4006E1091 3 Yes 130 to 270 A

L4006E1125 3 Yes 100 to 200 D

L4006H1004 1-1/2 100 to 2403 240 D

L4006G1022 3 100 to 200 7 H

L4008A1015 66 100 to 2403 5 to 30 A

L4008A1130 120 130 to 270 5 to 30 A

L4008A1189 66 130 to 270 5 to 30 A

L4008E1156 66 Yes 130 to 270 250 A

L4008E1305 66 Yes 100 to 240 240 A

L4008E1313 66 Yes 100 to 2003 A

L4008E1347 66 Yes 40 to 1803 A

L4006B1007 SPST - N.O. (make on rise)

Yes 1/2 1-1/2 100 to 240 5 Fixed A

L4006B1155 3 100 to 240 5 to 30 A

L6006A1004

SPDT

Yes 1/2 100 to 240 5 A

L6006A1012 Yes 1/2 1-1/2 100 to 240 5 to 30 A

L6006A1145 3 100 to 240 240 5 to 30 A

L6006A1244 3 100 to 240 5 to 30 A

L6006C1018 65 to 200 5 to 30 A

L6008A1093 66 -30 to 703 5 to 30 A

L6008A1192 66 100 to 240 240 5 to 30 A

L6008A1242 66 100 to 2003 5 to 30 A

Page 45: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

45

Single-Function Aquastat® Selection Guide

notes CRoss-RefeRenCe

Product Number1 Notes OEM or Trade Product Number

L4006A1009

L4006A1017 L4080B, L4080D Families, L4006A1058, L4006A1827, L4006A2015

L4006A1132 L4006A2023

L4006A1678

L4006A1959

L4006A1967

L4006A2007

L4006A2148

L4006E1042 Canada Only

L4006E1067 L4006E1091, L4006E1109, L4006E1117, L4006E1125, L4006E1133

L4006E1091

L4006E1125

L4006H1004 Bracket for Strap-On Mounting

L4006G1022 Canada Only

L4008A1015

L4008A1130

L4008A1189

L4008E1156 L4008E1040, L4008E1248, L4008E1321

L4008E1305 L4008E1271, L4008E1313

L4008E1313 Meets Certain State Specific Boiler Inspector Requirements

L4008E1347

L4006B1007

L4006B1155 L4006B1189, L4008B1163

L6006A1004

L6006A1012 L6006A1160, L6006A1269, L6006A1301, L6006A1327, L6006A1335

L6006A1145 Horizontal Mount Only L4006A1004

L6006A1244

L6006C1018 Includes Surface Mount Using 1/4" NPT Female Threads or Surface Mount Through Base of Case L6006C1034, L6006C1059

L6008A1093 L6008A1010

L6008A1192

L6008A1242

For a complete cross-reference, visit www.customer.honeywell.com

Oil/

Hyd

ron

ic C

on

tro

ls

Page 46: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

46

Multi-Function Aquastat® Selection Guide

* Replacement Sensors for the L7224U.

OS Number Length

50001464-001 12"

50001464-004 36"

50001464-005 48"

fuel low limit hiGh limit

Product Number Gas OilOperating Range,

Low Limit (˚F)

Differential

Temperature, Low

Limit (˚F)

Operating Range,

High Limit (˚F)

Differential

Temperature,

High Limit (˚F)

L6081A1036 • • 110 to 220 10-25 130 to 240 10 fixed

L8148E1265 • 180 to 240 15 fixed

L8124E1016 • 110 to 220 10 to 25 130 to 240 10 fixed

L8148J1009 • 120 to 240 8 fixed

l7224u1002 • 110 to 220 10 to 25 130 to 240 5 to 20 adj.

L8124A1007 • 110 to 220 10 to 25 130 to 240 10 fixed

L8124C1003 • 110 to 220 10 to 25 130 to 240 10 fixed

L8124G1020 • 110 to 220 10 to 25 130 to 240 10 fixed

L8124L1011 • 110 to 220 10 to 25 130 to 240 10 fixed

L8148A1017 • 140 to 240 8 fixed

Page 47: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

47

Oil/

Hyd

ron

ic C

on

tro

ls

Multi-Function Aquastat® Selection Guide

featuRes and funCtions CRoss-RefeRenCe

Product

Number

Factory

Stop (˚F)

Switching

Action

Anticipator

SettingMounting Notes OEM Part Number

L6081A1036 SPDT HL6081A1010, L6081A1069, L4081A1023, L4081A1148, L4081A1155, L4081A1171, L4081A1189, L4081A1197

L8148E12652 SPST: High

Limit & Circulator0.2 A V

L8148E1158, L8148E1182, L8148E1216, L8148E1065

L8124E10162 SPST: High &

Low Limit0.2 A

L8148J1009 2402 SPST: High

Limit & Circulator0.2 A V/H

l7224u10023 SPST: High

and Low Limit, Circulator

0.1 A V/H/F

Universal Oil, Digital Display and Settings, Used with Oil Burner

Applications, EnviraCOM® Communications

Replaces all members of these families: L8124A or C, L8148A or C, L7224A or C, L7248A or C, L8151A

L8124A1007 0.2 A VL8124A1015, L8124A1015, L8124A1049, L8124A1106, L8124A1114, L8124A1130, L8124A1155, L8124A1015

L8124C10032 SPST: High &

Low Limit0.2 A H L8124C1094, L8124C1102

L8124G10202 SPST: High &

Low Limit0.2 A V L8124G1004, L8124G1012

L8124L10112 SPST: High &

Low Limit0.2 A H

L8124L1003, L8124L1029, L8124G1038, L8124G1046

L8148A1017 2402 SPST: High

Limit & Circulator0.2 A H

L8148A1165, L8148A1157, L8148A1124, L8148A1090, L8148A1082, L8148A1009

For a complete cross-reference, visit www.customer.honeywell.com

Page 48: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

48

With our popular zone valves, Aquastats, and the energy-saving Aquatrol™ you can meet just about

every boiler room need with just one brand. AquaPUMP is the latest in Honeywell’s complete lineup

of hydronic heating solutions.

AquaPUMP

AquaPUMP eliminates the guesswork in the boiler room. With three sizes, multiple speeds for each size and the unique Twist-To-Fit flange, AquaPUMP has you covered for every application. And because a single AquaPUMP can replace a wide range of competitive models, you can handle nearly all retrofits with just one brand.

• Twist-To-Fit Universal Flange rotates 90° to fit every application

• Threaded conduit connection

• Stainless steel plate and can

• Impeller engineered for a quieter, more efficient operation

• Ceramic bearings and shaft

• Check valve available for all pumps separately

• 5-year Limited Warranty

Page 49: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

49

Oil/

Hyd

ron

ic C

on

tro

ls

Use this cross-reference tool to meet your installation needs. Each Honeywell circulator replaces

both regular and rotated flange models.

honeywell GRundfos taCo bell & Gossett aRmstRonG wilo

model Pump length speed single

speed 3-speed single speed 3-speed single

speed 3-speed

PC3f1558iuf00 6.5"

High

UP-42FUP-42F-FC

UPS15-58 HighUPS15-58-FC High

005F007F008F008F-IFC

00R High00R Med

NRF-22LR-20WR

Astro 30Astro 30-3Astro 50-3Astro 230C1

Star 16 Star S16 High

Medium

UP15-42FC UPS15-58 LowUPS15-58-FC Low

005F-IFC006F006F-IFC007F-IFC

00R Low NRF9F/LWNRF-25 Med

Star S16 Med

LowUP15-18FUP15-18F-FC

Star 5S16 Low

PC3f2699iuf00 6.5"

High

UP26-96FUP26-96F-FCUP26-116FUP26-116F-FC

UPS26-99 HighUPS26-99-FC High

0011F0011F-IFC0013F0013F-IFC

NRF-36 MedNRF-45 MedH-41

E7Astro 50Astro 50-3

S21 High

MediumUP26-64FUP26-99FC

UPS26-99 LowUPS26-99-FC Low

0014F0014F-IFC

Series 100 S21 Med

Low NRF-33 Star S21

Low

PC3f4344iuf00 8.5"

HighUP43-44FUP43-44F-FC

UPS43-44 HighUPS43-44-FC High

HVH-32

E16

Medium UPS43-44 Med

UPS43-44-FC Med0010F0012F-IFC

0010 Med NRF-33 H32

LowUPS43-44 LowUPS43-44-FC Low

0010F-IFC 0010 Low

The information in this table is based on publicly available information as of the date of this publication. Honeywell is not liable if information is found to be incorrect.If the cross referenced model uses a flow check valve, then use a flow check with the Honeywell model as well.

Page 50: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

50

Honeywell offers a complete range of relays, contactors and transformers for all your residential

and commercial HVAC applications. All Honeywell products are designed to exceed safety and

industry life cycle standards. In order to meet these criteria, a statistically significant sample of

Honeywell products are tested to failure and to our stringent qualification requirements. This testing

methodology enables Honeywell to verify that these products will exceed industry standards.

Relays/Contactors/Transformers

Relays Honeywell’s switching relays are available in multiple configurations for various applications. For

whatever you need — general purpose relays or electric heat relays — Honeywell has you covered.

• General Purpose and Heavy-Duty Switching Relays — R4222, R8222, R4228 and R8228 for use in

refrigeration and air-conditioning equipment, appliances and vending machines

• Time Delay Relay — ST82 combines the R8222 or R8228 relay for use in compressor-run air

conditioning and heat pump systems; this product features an electronic timer that delays blower shut

off after the compressor has shut off.

• Fully Enclosed Line and Low-Voltage Fan Relays — R4225 and R8225 for control of line voltage fan

motors and auxiliary circuits.

RelaysInput Voltage/Coil Voltage Switching Product Number Full Load Amp Rating Frequency Dimensions (in.) h x W X D Electrical Connections (main) Special Features

24 Vac DPST N.O. R8228D1018 5.5

A

1 7/8 x 2 5/32 x 2 3/8

Q

24 Vac

DPDT (1 P & 1 P Duty) R8222V1003

12

DPDT — Pilot Duty R8222N1011 Pilot duty

DPDT R8222D1014

DPDT ST82D1004 2 7/32 x 2 1/16 x 2 9/16 80 sec shut off delay

SPDT R8222B1067

1 7/8 x 2 5/32 x 2 3/8 120 Vac

DPDT — Pilot Duty R4222N1002

DPDT R4222D1013

SPDT R4222B1082

208/240 Vac DPDT R4222D1021

24 VacSPDT R8225A1017

14 B 2 11/16 x 2 1/2 x 3 7/16 LDPST N.O. R8225D1003

120 Vac SPDT, 1 N.O., 1 N.C. R4225A1008

24 Vac SPDT R8228B1012 18 A 1 7/8 x 2 5/32 x 2 3/8 Q

eleCtRiC heat Relays

24 Vac DPSTR8229A1005

7 B 2 3/16 x 2 3/32 x 2 1/4 ChSR8229A1021 Extra mounting hardware

eleCtRiC fuRnaCe seQuenCeR24 Vac R8330D1039 7.2 B 3 1/16 x 4 13/16 x 2 11/32 T

eleCtRiC heat ContaCtoR24 Vac DPST R8246A1038 30 2 3/16 x 2 1/4 x 3 5/16 Q, S

Frequency: A — 60 hz/50 hz; B — 60 hz, C — 50 hz SPST: Single Pole Single Throw

Approvals: UL, CSA DPST: Double Pole Single Throw

Temp Rating: -20˚ F to +150˚ F; 115˚ F max for R8225 DPDT Double Pole Double Throw

Connectors: ChS — Combination head Screw; L — Leadwires; Q — Quick connect; T — Terminals

SPDT: Single Pole Double Throw

Page 51: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

51

univeRsal tRansfoRmeRsElectrical Ratings

(VA)

Electrical Ratings

(Input Voltage)

Product Number

NEMA Rated

MountingMain

ConnectionsSecondary

ConnectionsFrequency

Dimensions (in.) h x W X D

NOTES

40 VA 208/240 Vac AT72D1733 yes M

L S

A 3 7/32 x 2 7/32 x 3 1/16 Only in Canada

50 VA120/208/240 Vac

AT87A1106 yes M A 2 15/16 x 2 7/32 x 2 1/4Built-in protection; Primary winding

burnout

20 VA120/208/240 Vac

AT120A1004 No M B 2 7/8 x 1 7/8 x 2 15/16 Metal end bells

40 VA120/208/240 Vac

AT140A1018 No M B 3 3/16 x 2 3/8 x 3 1/8 Metal end bells

75 VA120/208/240 Vac

AT175A1008 No M B 3 3/16 x 2 3/8 x 3 5/8 Metal end bells

tRansfoRmeRs19 VA 120 Vac AT20A1123

yes

F

L

L

A

2 x 2 1/4 x 1 7/8

40 VA120 Vac

AT72D1006 P S3 7/32 x 2 7/32 x (1 1/16 into x 2 in. above plate)

AT72D1089 F S 3 7/32 x 2 7/32 x 3 1/16

AT72D1188 P L 3 7/32 x 2 7/32 x 2 15/16

AT72D1683 M S

3 7/32 x 2 7/32 x 3 1/16AT72D1956 M L Only in Canada

208/240 Vac AT72D1691 M S

48 VA277 Vac AT87A1189 F L

2 15/16 x 2 7/32 x 2 1/4Energy limiting overload protection

480 Vac AT87A1155 F L Energy limiting overload protection

20 VA 120 Vac AT120B1028

No

F L

B

1 11/16 x 3 3/16 x 1 3/4 Metal end bells

40 VA

120 VacAT140A1000 M S 3 3/16 x 2 3/8 x 3 1/8 Metal end bells

AT140B1206 F L 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps

120/208/240 Vac

AT140B1214 F L 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps

50 VA

120/208/240 Vac

AT150A1007 M S 1 11/16 x 3 3/16 x 1 3/4 Metal end bells

AT150F1022 M L 3 3/16 x 2 3/16 x 3 5/8 Button for resetting circuit breaker &

metal end bells

208/277/480 Vac

AT150F1030 M L 3 3/16 x 2 3/16 x 3 5/8 Button for resetting circuit breaker &

metal end bells

277 Vac AT150B1252 F L, Q L, Q A 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps

75 VA

120/208/240 Vac

AT175F1023 M

L

L

B

3 3/16 x 2 3/16 x 3 15/16 Button for resetting circuit breaker &

metal end bells

208/277/480 Vac

AT175F1031 M L 3 3/16 x 2 3/16 x 3 15/16 Button for resetting circuit breaker &

metal end bells

120 Vac AT88A1005 F L

A 2 15/16 x 2 3/16 x 3 5/16 Internally fused secondary for overload

protection208/240 Vac AT88A1021 F L

480 Vac AT88A1047 F L

Frequency: A — 60 hz/50 hz; B — 60 hz;

Mounting; C — Conduit ; F — Foot; P — Plate; M — Foot, Conduit, Plate (F models do not come with plate options)

Connections: L — Leadwires (9 in. to 13 in.); Q — Quick Connects; S — Screw Terminals

Approval: UL, CSA

TransformersHoneywell offers NEMA — standard DC20-1992 and general purpose

transformers. These transformers are available with single or multiple input

voltages and with foot, conduit and plate mounting options. Transformers with

circuit breakers that can be manually reset by pressing a button are also available.

Honeywell also designs transformers for specific environmental requirements and

with specialized termination options.

Hea

tin

g/C

oo

ling

Dev

ices

Page 52: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

52

Relays/Contactors/Transformers

Contactors Honeywell offers definite-purpose contactors for heating, cooling and refrigeration applications.

• Replace most competitive models

• Compact size for easier installation

• Meet ARI 780 and UL/CSA/CUR standards.

• Box lugs for easier installation (Deluxe PowerPRO)

• Sealed coils extends life (Deluxe PowerPRO)

• Baked finish for added durability

Connectors:BhS — Binding head Screw; Q — Quick Connect; SS — Sems Screw; ChS — #10-32 Combination head Screw; S — #6 Screw; TCS — Terminal Clamp Screw; LC — Lug Connector

Approvals: UL, CSA

Temp Rating: -4˚ F to 149˚ F ARI - 780:500,000 cycle mechanical life; 200,000 cycle electrical life; 10,000 cycle recycle life

Cross Reference InformationeConomy ContaCtoRs

Poles

Contact Ratings (AFL @

240, 277, 480, 600

Vac)

Input Voltage/Coil Voltage

Product Number

Dimensions (in.) h x W x D

Main Connections

Coil Connections

Contact Ratings

(Resistive @ 240,

277, 480, 600 Vac)

honeywell Cutler hammer Furnas Mars

1 with shunt 30 24 Vac DP1030A1001 2 7/32 x 2 1/2 x 3 5/16

Screw Terminal Q

48 A DP1030A1000 C25CNB130T 45EG10AJA 91320, 17311

2

3024 Vac DP2030A1004 3 1/4 x 3 5/8 x 3 7/8 48 A DP2030A1003 C25BNB230T 45EG2OAJ 61354, 17321120 Vac DP2030B1003 2 7/32 x 3 5/16 x 2 5/32 40 A DP2030B1002 C25BNB230A 45EG2OAF 61346, 17322

208/240 Vac DP2030C1002 2 7/32 x 2 1/2 x 3 5/16 40 A DP2030C1001 C25BNB230B 45EG2OAG 61347, 17323

4024 Vac DP2040A1003

2 3/8 x 3 5/16 x 2 50 ADP2040A1002 C25BNB240T 45GG20AJ 61355, 17421

120 Vac DP2040B1002 DP2040B1001 C25BNB240A 45GG20AF 61356, 17422208/240 Vac DP2040C1001 DP2040C1000 C25BNB240B 45GG20AG 61357, 17423

PoweRPRo ContaCtoRs — aRi 780/790 Rated 1 with shunt

2524 Vac

DP1025A5006 2 7/32 x 2 1/2 x 3 5/16

Box Lug

Q

30 A DP1025A5005 Not Available 45DG10AJA 6131530 DP1030A5014 2 7/32 x 2 1/2 x 3 5/16 48 A DP1030A5013 Not Available 45EG10AJA 13101, 61320, 6172040 DP1040A5005 2 23/64 x 2 1/2 x 3 5/16 50 A DP1040A5004 Not Available 45GG10AJA 61330

2

2024 Vac DP2020A5022 2 7/32 x 2 1/2 x 3 5/16 30 A DP2020A5021 Not Available 45CG20AJ 61310120 Vac DP2020B5039 2 7/32 x 2 1/2 x 3 5/16 30 A DP2020B5038 Not Available 45CG20AF 61336, 14122

30

24 Vac DP2030A5005 3 1/4 x 2 5/8 x 3 3/4

48 A

DP2030A5004 C25DND230T 45EG2OAJ 61345, 13104, 91321, 60510

24 Vac DP2030A5013 3 1/4 x 2 5/8 x 3 3/4 DP2030A5012 60510120 Vac DP2030B5004 2 7/32 x 3 5/16 x 2 5/32 DP2030B5003 C25DND230A 45EG2OAF 61346, 13105,120 Vac DP2030B5012 2 5/16 x 3 5/16 x 2 5/32 DP2030B5011 Not Available 60031

208/240 Vac DP2030C5003

2 7/32 x 2 1/2 x 3 5/16

DP2030C5002 C25DND230B 45EG2OAG 61347, 13106, 60512, 60032

208/240 Vac DP2030C5011 DP2030C5010 Not Available Not Available 60512 91323

277 Vac DP2030D5002 DP2030D5001 Not Available Not Available 60153

40

24 Vac DP2040A5004

2 23/64 x 3 3/16 x 1 15/16 50 A

DP2040A5003 C25DNF240T 45GG20AJ 13107, 91421, 61355, 61755, 60525,

120 Vac DP2040B5003 DP2040B5002 C25DNF240A 45GG20AF 13108, 91422, 61356, 61756,

208/240 Vac DP2040C5002 DP2040C5001 C25DNF240B 45GG20AG 13109, 91423, 61357, 61757, 60527, 14423

3

30

24 Vac DP3030A5004

3 7/64 x 3 5/8 x 2 13/32

Q, S

40 A

DP3030A5003 C25DND330T 42BF35AJ 61430, 13113, 60515, 13007, 91331

120 Vac DP3030B5003 DP3030B5002 C25DND330A 42BF35AF 61431, 13114, 91332

208/240 Vac DP3030C5002 DP3030C5001 C25DND330B 42BF35AG 61432, 13115, 91333, 60517, 13009

40

24 Vac DP3040A5003

50 A

DP3040A5002 C25DNF340T 42CF35AJ 60530, 61445, 13013 91431

120 Vac DP3040B5002 DP3040B5001 C25DNF340A 42CF35AF 61446

208/240 Vac DP3040C5001 DP3040C5000 C25DNF340B 42CF35AG 60532, 60182, 61447, 13015, 91433

50

24 Vac DP3050A5002

63 A

DP3050A5001 C25DNJ350T 42DF35AJ 61460, 13619, 91531120 Vac DP3050B5001 DP3050B5000 C25DNJ350A 42DF35AF 61461

208/240 Vac DP3050C5010 DP3050C5009 C25DNJ350B 42DF35AG 60217, 60202, 61462, 13621, 91533

60

24 Vac DP3060A5001

75 A

DP3060A5000 C25FNF360T 42EF35AJ 61470 13625 91631120 Vac DP3060B5010 DP3060B5009 C25FNF360A 42EF35AF 61471

208/240 Vac DP3060C5009 DP3060C5008 C25FNF360B 42EF35AG 60227, 60207, 61472, 13627, 91633

75

24 Vac DP3075A50174 7/16 x 5 x 3 3/44 7/16 x 5 x 3 3/44 7/16 x 5 x 3 3/44 7/16 x 5 x 3 3/44 7/16 x 5 x 3 3/4

95 A

DP3075A5016 C25FNF375T 42FE35AJ 60235, 61475, 13240, 91731

120 Vac DP3075B5016 DP3075B5015 C25FNF375A 42FE35AF 60237, 61476

208/240 Vac DP3075C5015 DP3075C5014 C25FNF375B 42FE35AG 60245, 61477, 13242, 91733

90120 Vac DP3090B5007 120 A DP3090B5006 C25GNF390A 42GE35AF 61491

208/240 Vac DP3090C5006 120 A DP3090C5005 C25GNF390B 42GE35AG 60247, 61492, 13262

4 4024 Vac DP4040A5002

2 5/8 x 3 3/4 x 3 7/64 50 ADP4040A5001 C25ENF440T 42CF25AJ 61450, 13016

120 Vac DP4040B5001 DP4040B5000 C25ENF440A 42CF25AF 61451208/240 Vac DP4040C5010 DP4040C5009 C25ENF440B 42CF25AG 61452

Page 53: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

53

Hea

tin

g/C

oo

ling

Dev

ices

Fan CentersFor fan centers (relay and transformer combination), R8285 and R8239 NEMA

rated units offer low-voltage control of line-voltage fan motors and

auxiliary circuits in heating, cooling or air-conditioning systems.

fan CenteRsElectrical

Ratings (VA) Electrical Ratings

(Input Voltage)Switching

Product Number

NEMA Rated

Dimensions (in.) h x W X D

Main Connections

Secondary Connections

Frequency Special Features

40 VA 120 Vac

DPDT R8239B1043

yes4 1/2 x 4 3/16 x

3 3/32

L L A

Super Tradeline*

DPST R8239D1007 Available only in Canada

DPST (1 Power, 1 Pilot) R8239D1015 Tradeline

SPDT R8239A1052 Tradeline

50 VA 120/208/240 Vac DPDT R8239B1076 Super Tradeline

40 VA120 Vac SPDT R8285A1048

No4 3/16 x 4 1/2 x

2 13/16

Tradeline

120/208/240 Vac DPDT R8285B1053 Tradeline

50 VA 120 Vac DPDT R8285D5001

Frequency: A — 60 hz/50 hz; B — 60 hz SPST: Single Pole Single Throw

Approvals: UL, CSA DPST: Double Pole Single Throw

Temp Rating: -20˚ F to +105˚ F DPDT: Double Pole Double Throw

Connectors: L — Leadwires SPDT: Single Pole Double Throw

Mounting: Standard 4 x 4 in. junction box

* Super Tradeline models include extra hardware.

defRost ContRolleROperation Time On Time Off — Selectable Product Number

Remote Contact Closure 10 min. 50/70/90 min. ST74A1053

Defrost ControllerChoose the ST74 low-voltage time/temperature defrost controller for heat pumps.

• Resets the defrost cycle by remote contact closure.

• Mounts in outdoor section of heat pump.

• Utilizes special moisture barrier to protect circuitry.

auXiliaRy switChes

Product Number Circuits ConfigurationDimensions (in.)

h x W x DContact Ratings

(Resistive)Maximum (inrush) Current

at 120/240/480/600 VUse With

DP3AUX-1NO 1 Normally Open snap-on

2 26/32 x 2 17/32 x 7/16 10 A 60/30/15/12 AmpsDP3030 – DP3090

Contactors

DP3AUX-1NC 1 Normally Closed snap-on

DP3AUX-1NO-1NC

2

Normally Closed/Normally Open snap-on

DP3AUX-2NO Normally Open snap-on

DP3AUX-2NC Normally Closed snap-on

Auxiliary SwitchesHoneywell Auxiliary Switches work Honeywell models of 3-pole contactors.

Page 54: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

54

Sales Collateral

With Honeywell, you’ll have access to sales materials that you can use to help grow your business. To order

these and other residential combustion pieces visit literature.honeywell.com or customer.honeywell.com

Gas Controls Quick Reference Guide 63-9581GUni

vers

al G

as V

alve

S

elec

tor

Gui

de/C

ross

Ref

eren

ce Trad

e Re

plac

emen

ts

(Dou

ble-

chec

k sp

ecifi

catio

ns

befo

re re

plac

emen

t)

Spec

ifica

tions

Acce

ssor

ies

Com

petit

ive

Repl

acem

ent

(dou

ble-

chec

k sp

ecifi

catio

ns

befo

re re

plac

emen

t)

Univ

ersa

l

Serv

ice

Part

Dire

ct

Serv

ice

Part

Repl

acem

ent

Open

ing

Char

acte

ristic

s

(sta

ndar

d, s

tep)

Inle

t/Out

let

Size

(in.

)

Pres

sure

Regu

lato

r

Setti

ng (p

si)

Tem

pera

ture

Rang

e

Incl

udes

Hone

ywel

l W

hite

-Ro

dger

sRo

berts

haw

Q340

Ther

moc

oupl

e

3/4"

x 1

/2"

Redu

cer

Bush

ing

Natu

ral t

o LP

Conv

ersi

on K

it

3/4"

St

raig

ht

Flan

ge

1/2"

x 3

/8"

Redu

cer

Bush

ing

Rem

ote

Rod

Adap

ter

VR

8300

A45

16

VR

8300

A45

08S

tand

ard

3/4

" x

3/4"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eTw

oO

neN

one

Non

eN

one

VR

8300

A40

03,

VR

8300

A40

11,

VR

8300

A40

37,

VR

8300

A40

45,

VR

8300

A45

57,

VR

8300

A45

65

36C

01-4

05,

720

-406

(72

00E

R)

VR

8300

A35

00S

tand

ard

1/2"

x 3

/4"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eO

neO

neN

one

Non

eN

one

VR

8300

A31

04,

VR

8300

A31

20,

VR

8300

A31

53,

VR

8300

A31

61,

VR

8300

A32

03,

VR

8300

A35

00,

VR

8300

A35

59,

VR

8300

A35

67,

VR

8300

A35

75

36C

03-3

00,

36C

03-4

00,

36C

03-4

33,

36C

03-2

58

720-

404

(720

0ER

)

VR

8300

A45

16S

tand

ard

3/4"

x 3

/4"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

One

Two

One

Non

eN

one

Non

e

VR

8300

A40

03,

VR

8300

A40

11,

VR

8300

A40

37,

VR

8300

A40

45,

VR

8300

A45

57,

VR

8300

A45

65

700-

400

VR

8245

M25

30

VR

8204

A20

76S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eN

one

One

One

One

Non

e

VR

8204

A12

01,

VR

8204

A12

19,

VR

8204

A20

01,

VR

8204

A21

75,

VR

8204

A28

03

VR

8204

M10

91S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eN

one

One

One

One

Non

eV

R82

04M

1075

36E

01-2

04,

36E

01-2

05,

36E

01-2

06,

36E

01-3

05,

36E

93-3

04

722

-079

(20

00IP

ER

HC

)

VR

8205

A20

24S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eN

one

One

One

One

Non

e

36G

22-2

1472

2-05

1 (2

000D

ER

HC

)

VR

8245

M25

30S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eN

one

One

Non

eO

neN

one

VR

8205

M11

06,

VR

8205

M23

10,

VR

8205

M24

43,

VR

8205

M24

50,

VR

8205

M24

76

36E

36-3

04,

36E

22-2

14

720-

079

(720

0IP

ER

),

720-

080

(720

0IP

ER

-LP

)

VR

8345

H45

55

VR

8205

H10

03S

low

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eN

one

Non

eN

one

Non

eN

one

VR

8305

H40

13,

VR

8305

H40

39

VR

8304

H45

03S

low

3/4

" x

3/4"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eN

one

One

Non

eN

one

Non

eV

R82

04H

1006

720-

070

(720

0IP

ER

-S7C

),

720-

071

(720

0IP

ER

-S7C

),

720-

072

(720

0IP

ER

-S7C

),

720-

073

(720

0IP

ER

-LP

-S7C

)

VR

8345

H45

55S

low

3/4

" x

3/4"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eTw

oO

neN

one

Non

eN

one

36E

98-3

04,

36E

24-2

14,

36E

52-2

14

700-

052

VR

8345

M43

02

VR

8304

M35

09S

tand

ard

1/2"

x 3

/4"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eO

neO

neN

one

Non

eN

one

VR

8304

M40

02

VR

8304

M45

07S

tand

ard

3/4

" x

3/4"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eTw

oO

neN

one

Non

eN

one

VR

8305

M35

06S

tand

ard

1/2"

x 3

/4"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eO

neO

neO

neN

one

Non

e

VR

8305

M40

66,

VR

8305

M41

65,

VR

8305

M42

31

36G

22-2

14,

36C

68-4

23 7

20-0

51 (

7200

DE

R)

VR

8345

M43

02S

tand

ard

3/4

" x

3/4"

3.5"

wc

(0.8

7 kP

a)

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eTw

oO

neN

one

Non

eN

one

36E

36-3

04,

36C

68-4

23

VR

8345

Q45

63

VR

8205

Q25

552-

Sta

ge 1

/2"

x 1/

2"

1.7"

wc

Low

Fire

;

3.5"

wc

Hig

h F

ire

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eN

one

One

Non

eO

neN

one

VR

8205

Q26

62,

VR

8205

Q27

46,

VR

8205

Q27

87,

VR

8205

Q23

81

36E

54-2

14

VR

8304

Q45

112-

Sta

ge 3

/4"

x 3/

4"

1.7"

wc

Low

Fire

;

3.5"

wc

Hig

h F

ire

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eTw

oO

neN

one

Non

eN

one

36C

76-4

06,

36C

76-4

20,

36C

76-4

63

VR

8305

Q45

002-

Sta

ge 3

/4"

x 3/

4"

1.7"

wc

Low

Fire

;

3.5"

wc

Hig

h F

ire

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eO

neO

neN

one

Non

eN

one

VR

8305

Q41

46

36D

13-2

08,

36D

13-4

05,

36G

54-2

14

VR

8345

Q45

632-

Sta

ge 3

/4"

x 3/

4"

1.7"

wc

Low

Fire

;

3.5"

wc

Hig

h F

ire

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eTw

oO

neN

one

Non

eN

one

36E

96-3

14 7

20-0

82 (

7200

IPE

R2-

4)

VR

8200

A27

44

VR

8200

A21

24S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

One

Non

eO

neO

neO

neN

one

VR

8200

A21

16,

VR

8200

A22

64

720-

400

(72

00E

R),

720-

402

(720

0ER

)

VR

8200

A21

32S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eN

one

One

One

One

Non

e

720-

400

(72

00E

R),

72

0-40

2 (7

200E

R)

VR

8200

A27

44S

tand

ard

1/2"

x 1

/2"

3.5"

wc

(0.8

7 kP

a)

1˚ to

175

˚ F

(-18

˚ to

79˚

C)

Non

eN

one

One

One

+ O

ne

Elb

ow

One

Non

e

VS

820A

1088

VS

820A

1054

Sta

ndar

d 3

/4"

x 3/

4"3.

5" w

c

(0.8

7 kP

a)

32˚

to 1

75˚

F

(0˚

to 7

9˚ C

)N

one

Two

Non

eN

one

One

Non

e

VS

820A

1005

,

VS

820A

1013

,

VS

820A

1047

,

VS

820A

1278

,

VS

820A

5204

,

VS

820A

1922

36C

03U

-300

,

36C

03U

-333

,

36C

03U

-400

,

36C

03U

-433

VS

820A

1336

Sta

ndar

d 3

/4"

x 3/

4"10

.0"

wc

(2.4

9 kP

a)

32˚

to 1

75˚

F

(0˚

to 7

9˚ C

)N

one

Two

Non

eN

one

One

Non

e

VS

820A

1211

,

VS

820A

1740

,

VS

820A

1120

,

VS

820A

1898

,

VS

820A

1872

,

VS

820A

1906

VS

820A

1088

Sta

ndar

d 3

/4"

x 3/

4"3.

5" w

c

(0.8

7 kP

a)

32˚

to 1

75˚

F

(0˚

to 7

9˚ C

)N

one

Two

One

Non

eO

neYe

s

VS

820A

1807

,

VS

820A

2003

,

VS

820A

1815

,

VS

820A

1039

,

VS

820A

2011

Not

es:

All

pilo

ted

valv

es h

ave

a 1/

4" c

ompr

essi

on fi

tting

.

A

ll th

e V

R v

alve

s co

me

set f

or n

atur

al g

as, b

ut c

an b

e co

nver

ted

to L

P g

as.

T

he V

S82

0A10

54 is

for

natu

ral g

as. T

he V

S82

0A13

36 is

for

LP g

as.

A

ll th

e V

R v

alve

s ha

ve in

let a

nd o

utle

t pre

ssur

e ta

ps. T

he V

S82

0 va

lves

hav

e ju

st a

n ou

tlet p

ress

ure

tap.

* Fo

r a

com

plet

e cr

oss

refe

renc

e vi

sit w

ww

.cus

tom

er.h

oney

wel

l.com

.

Sm

artV

alve

S

elec

tor

Gui

de/C

ross

Ref

eren

ceSp

ecifi

catio

ns

Cros

s-Re

fere

nce

Igni

tion/

Appl

icat

ion

Univ

ersa

l

Serv

ice

Part

Open

ing

Char

acte

ristic

sAm

bien

t Tem

pera

ture

Rang

e

Incl

udes

OEM

Bra

nds

Repl

aces

Natu

ral t

o LP

Conv

ersi

on K

it

3/4"

x 1

/2"

Redu

cer B

ushi

ngs

Exte

nsio

n

Harn

ess

HS

I/

Wat

er H

eate

r

SV

9570

A25

18S

tand

ard

Ope

ning

0˚ to

150

˚ F

No

Non

eN

o

AO

Sm

ith

SV

9570

A20

54, S

V95

70A

2070

, SV

9570

A20

96

SV

9570

A25

26 (

LP)

AO

Sm

ith

SV

9570

A20

62, S

V95

70A

2088

, SV

9570

A21

87

Inte

rmitt

ent H

SI

Pilo

t with

Com

bust

ion

Air

Con

trol

and

Lim

it

Mon

itorin

g/

Forc

ed A

ir

Fur

nanc

e

SV

9541

Q25

612-

Sta

ge-4

0˚ to

175

˚ F

(-40

to 7

9˚ C

)

Yes

Non

e

No

ICP,

Hei

l, Te

mps

tar,

Arc

oaire

, Com

fort

mak

er,

Kee

pRite

SV

9540

Q24

64, S

V95

41Q

3098

SV

9641

M45

10

Sta

ndar

d O

peni

ng

Yes

Two

ICP,

Hei

l, Te

mps

tar,

Arc

oaire

, Com

fort

mak

er,

Kee

pRite

,

Mes

tek,

Sla

ntF

in

SV

9541

M20

94, S

V95

40M

2229

, SV

9540

M22

60, S

V96

40M

4116

, SV

9640

M41

24,

SV

9540

M22

78, S

V95

40M

2245

, SV

9640

M31

26, S

V96

40M

4132

Dire

ct Ig

nitio

n/

Gen

eral

App

licat

ion

SV

9510

M25

11S

tand

ard

Ope

ning

-40˚

F to

+17

5˚ F

(-40

˚ C

to +

79˚

C)

Yes

Non

eN

o

Mod

ine

SV

9510

M23

47, S

V95

10M

2362

, SV

9410

M29

02, S

V95

10M

2412

, SV

9510

M23

54,

SV

9410

M29

10, S

V95

10M

2388

, SV

9510

M24

20

SV

9520

M25

36

SV

9420

M23

31, S

V95

20M

2403

, SV

9420

M23

23

SV

9510

K25

39S

low

Ope

ning

-40

to 1

75˚

F

(-40

to 7

9˚ C

)

Rob

erts

Gor

don

SV

9510

H22

28, S

V95

10K

2133

, SV

9510

K21

58, S

V95

10K

2141

, SV

9510

K21

66

SV

9520

H85

13Fa

st-S

low

Ope

ning

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Arm

stro

ng, C

onco

rd,

Aire

Eas

e

SV

9520

H80

42, S

V95

20H

8034

, SV

9520

H80

67, S

V95

20H

8026

Inte

rmitt

ent

HS

I Pilo

t/

Gen

eral

App

licat

ion

SV

9601

M45

71

Sta

ndar

d O

peni

ng-4

0˚ to

175

˚ F

(-40

˚ to

79˚

C)

Yes

Two

No

SV

9601

M41

67, S

V96

01M

3003

,SV

9601

M42

25

SV

9501

M25

28

Non

e

ICP,

Hei

l, Te

mps

tar,

Arc

oaire

, Com

fort

mak

er,

Kee

pRite

SV

9501

M20

56, S

V95

01M

2718

, SV

9501

M27

26, S

V95

01M

2031

, SV

9501

M20

49,

SV

9501

M20

80, S

V95

01M

2239

, SV

9501

M27

00, S

V95

01M

2734

, SV

9501

M27

42,

SV

9501

M20

64

SV

9501

M81

29Fa

st-F

ast

Yes

SV

9501

M81

03

SV

9502

H25

22S

low

Ope

ning

0˚ to

175

˚ F

(-18

˚ to

79˚

C)

Laar

s, U

tica,

Arm

stro

ng,

Con

cord

, Aire

Eas

e

SV

9501

H34

15, S

V95

01H

2417

, SV

9501

H24

09, S

V95

02H

1706

, SV

9502

H27

04,

SV

9501

H34

23, S

V95

01H

2425

SV

9602

P48

16

Ste

p O

peni

ng

-40˚

to 1

75˚

F

(-40

˚ to

79˚

C)

Non

eTw

oYe

s

Bur

nham

, IC

P, H

eil,

Tem

psta

r, A

rcoa

ire,

Com

fort

mak

er, K

eepR

ite

SV

9501

P20

04, S

V96

01P

4107

, SV

9501

P20

53, S

V95

02P

2101

, SV

9602

P41

05

SV

9602

P48

24

Bur

nham

SV

9501

P20

87, S

V96

01P

4172

, SV

9502

P21

27, S

V96

02P

4121

SV

9602

P48

32

Bur

nham

SV

9501

P20

20, S

V95

01P

2046

, SV

9601

P41

49, S

V96

01P

4164

, SV

9502

P21

19,

SV

9502

P21

35, S

V96

02P

4113

, SV

9602

P41

39

SV

9602

P48

40

SV

9601

P41

15

S

elec

tor

Gui

de/C

ross

Ref

eren

ce

Prod

uct

Num

ber

Appl

icat

ions

Tim

ings

Feat

ures

and

Fun

ctio

ns

Cros

s-Re

fere

nce

Igni

tion

Syst

emFl

ame

Sens

er

Igni

tion

Sequ

ence

(Not

e 1)

Igni

tion

Tria

ls To

Lock

out

(Not

e 1)

Igni

tion

Tria

l Ti

me

(Not

e 1)

Betw

een

Tria

l Ti

me

(Not

e 1)

Pre-

Purg

e

Flam

e Fa

ilure

Resp

onse

Ti

me

Type

of

Ga

s

Igni

tion

Sour

ce

Typi

cal

Igni

tion

Hard

war

eIn

clud

esHo

neyw

ell

Whi

te-

Rodg

ers

Robe

rt-Sh

awJo

hnso

n

Cont

rols

S89

10U

1000

Line

Volt

Hot

Sur

face

Igni

tion

1 or

2

Rod

sP

1 or

3F

ield

Sel

ecta

ble

4 or

7 S

ec.

Fie

ld

Sel

ecta

ble

96 S

ec. –

3 Tr

ial

Mod

e O

nly

32 S

ec.

1.5

sec.

Nat

or L

P

Sw

itche

d

Mai

ns

Nor

ton

201,

Nor

ton

271,

Hot

sur

face

elem

ents

,

Q35

4

flam

e ro

d

S89

C10

04, S

89C

1007

, S89

C10

12,

S89

C10

46, S

89C

1087

, S89

C11

03,

S89

D10

02, S

89G

1005

, S89

G10

11,

S89

G10

13, S

89G

1021

, S89

G10

29,

S89

G10

47, S

89H

1003

, S89

H10

11,

S89

H10

29, S

89J1

008,

S89

0D10

06,

S89

0G10

03, S

890G

1037

,

S89

0H10

02, S

890H

1010

50E

47 1

-79,

101-

179,

201-

279,

301-

379,

5047

F 1

-79,

101-

179,

201-

279,

301-

379

HS

780-

17N

L, 1

04A

,

306A

, 308

A,

HS

780-

17N

R 1

04A

,

306A

, 308

A,

HS

780-

34N

L 10

8A,

304A

, 306

A, 3

08A

,

312A

, HS

780-

34N

R

104A

, 306

A, 3

08A

,

312A

, HS

780-

34P

L

308A

S86

10U

3009

Inte

rmitt

ent

Pilo

t

1 or

2

Rod

sC

C

15 S

ec.

or 9

0 S

ec.

Fie

ld

Sel

ecta

ble

5-m

inut

e

Del

ay A

fter

Faile

d Tr

ial

for

Igni

tion

0 S

ec. o

r S

0

Sec

. Fie

ld

Sel

ecta

ble

2.0

Sec

.

Max

Nat

or L

PIn

tern

alQ

345,

Q34

51,

Q34

52

Inte

gral

Dam

per

Con

nect

or

S86

00A

1001

, S86

00B

1009

, S86

00C

1015

,

S86

00F

1000

, S86

00F

1034

,S86

00F

1042

,

S86

00H

1006

,S86

00H

1022

, S86

00H

1048

,

S86

00H

1071

, S86

00H

1089

, S86

00H

1097

,

S86

00M

1013

,S86

00M

1021

, S86

10A

1009

,

S86

10B

1007

, S86

10B

1015

, S86

10C

1005

,

S86

10C

1013

, S86

10F

1008

, S86

10F

1016

,

S86

10F

1024

, S86

10F

1032

, S86

10F

1032

,

S86

10H

1012

, S86

10H

1038

, S86

10H

1046

,

S86

10H

1053

, S86

10H

1079

, S86

10M

1003

,

S86

10M

1029

, S86

20H

1002

, S86

20H

1028

50D

50-8

43

780-

701,

710

-713

, 715

,

735-

737,

SP

710,

SP

715,

SP

720,

SP

730,

SP

735,

SP

750

Ser

ies

CS

A42

, 43,

44, 4

5, 4

6,

48, 4

9, G

60,

G65

, G67

,

G77

0 S

erie

s

Not

es:

1. Ig

nitio

n S

eque

nce

C

Con

tinou

s re

try.

P

The

num

ber

of tr

ials

for

igni

tion

and

tria

l tim

e is

det

erm

ined

by

the

sele

ctio

n ta

b. If

a s

elec

tion

tab

is n

ot in

stal

led,

the

mod

ule

will

ope

rate

at f

our

seco

nds

tria

l tim

e an

d on

e ig

nitio

n tr

ial.

* Fo

r a

com

plet

e cr

oss

refe

renc

e vi

sit w

ww

.cus

tom

er.h

oney

wel

l.com

.

Uni

vers

al I

gniti

on M

odul

e

ResidentialCombustionGas Controls Quick Reference Guide

63-9581G PRJuly 2009© 2009 Honeywell International Inc.

Automation and Control Solutions In the U.S.: Honeywell 1985 Douglas Drive North Golden Valley, MN 55422-3992

In Canada: Honeywell Limited 35 Dynamic Drive Toronto, Ontario M1V 4Z9 www.honeywell.com

Learn MoreCall toll-free 1-800-328-5111,e-mail [email protected] or

visit customer.honeywell.com.Residential Tech Support: 1-800-468-1502 Burner Boiler Support: 1-888-516-9282Residential Zoning: 1-800-828-8367Customer Service: 1-888-793-8193Sales Support: 1-800-828-8367Canadian Technical Support: 1-800-405-9835

Canada Customer Care: 1-800-565-6282

2009-2010

S9200U1000 Replaces These Integrated Furnace ControlsOEM Brand

SKUAmana10207701, 10207702, 10207703,10207710Goodman

1809913, 18099-13S, B180996, B1809906, B18099-6, B18099-06,

B1809908, B18099-08, B1809910, B18099-10, B18009910,

B180099-10, B1809913, B18099-13, B1809913S, B18099-13S,

B18009913, B180099-13, CARB1809913S

ICM

ICM280ICP

1010806, 1380-686, 1380-699

Lennox

1214201 Nordyne

624557, 6245570, 624557-0, 624564, 6245640, 624591, 624591A,

624591-A, 624591-B, 624591-C, 624591-D, 624628, 624628-0,

6246310, 624631-0, 624631A, 624631-A, 624631-B, 710128A, 902378,

902696, 903106, CAR903106

Rheem/ Robert Shaw62-24268-01, 62-24268-02, 695-200, 62-24268-03

Texas Instruments

6DT-1, 6DT-2, 61F3, 41F-5United Technologies1012-925A, 1012-925B, 1012-925C, 1012-955A, 1012955A, 1012-

83-9651B, 1012-930, 1012933D, 1012-933D, 1012-83-9336AHSC1, 1012-83-9337A

White-Rodgers

50A50-209, 50A50-230, 50T35730, 50T35-730, 50T35743, 50T35-743,

50A55-120, 50A55-286, 50A55-843, 50A50-143, 50A50-286, 50A50-

438, 50A50-205, 50A50-206, 50A50-207,

50A50-142, 50A50-110, 50A50-111, 50A50-112, 50A50-113, 50A50-

296, 50A55-143, 50A55-288, 50A50-285, 50A55-285, 50A50-288,

50A50-408, 50A50-241, 50A55-241

York

03100662000, 031-00662-000, 031-00662-700, 031-01140-000,

031-01140-001, 031011140002, 031-01140-002, 031-01140-701,

031-01140-702, 031-01234-000, 031-01235-000, 031-01234-700, 031-

01235-700, 031-01250-000, 031-01266-000, 31-01267-00, 031-01267-

000, 031-01267-001, 031-01267-001A, 031-01284-000, 031-01933-000,

031-01972-000, 031-01973-000,

031-02166-000, 031-09166-000, 031-09167-000, 331-01933-000,

331-01972-200, 331-09167-000, 43101972100, 431-01972-

100, P03101267001, P031-01267-001, PTH031011400-00,

CAR33101972200, CAR03101973000, CAR50A55843, G951ADB1401,

G951ADB1401C, G951ADB-1401C, G951ADB1402, G951ADB-1402,

G951AEB-1403, 031-00662, 031-01266-000

* Always refer to box label for most updated cross reference. For wiring harness and timing specifications see installation guide.

S9200U1000

Glowfly™ Universal Hot Surface IgniterQ3200U Igniter Bracket Replacement Cross Referencea

Manufacturer OEM # Q3200U Bracket1 Manufacturer OEM # Q3200U

Bracket1 Manufacturer OEM # Q3200U Bracket1

American Road Equip. 201WA

Modine5H76032A C

Tempstar1096048

D

Arco Air 1096048

DMor-Flo 3200618

A

Trane

340039P01A

1380680

511-330-193 B

B138196P01 B

Armstrong Air38322B001

A

Nordyne105141000

A B144676P01 A

Carrier/Bryant/Payne

LH33ZS001

B or E2

632-0770

B144676P02 B

LH33ZS001A

632-0880

B340039P01 A

LH33ZS002

Norton/St Gobain

201

BIGN23

A

LH33ZS002A

271

IGN26B

LH33ZS003

201D

A

IGN30B

LH33ZS003A

201K

IGN34A

LH33ZS004

201LViessman

9302-094A

Claire Bros. C-238

A201N

Wayne Home Equip. 62821-001A

C242

201R

62821-002

Coleman 1474-051A

201W

Weil McLain511-330-139

B

1474-052

271N

511-330-190

Comfort Maker1096048

D

271NMD

511-330-193

Detroit Radiant201D

A

271P

A White LB120-07549

A

DMO Ind.20834

A

271W

White-Rodgers

767A-301A

Dornback Furnace271W

ARaypak

600915B

767A-303F

Ducane20015201

BRheem

62-22441-01 A

767A-306

A

Enero Tech10399

ARoberts Gordon 90434300 B

767A-311

Evcon 1474-051A

90436600 A

767A-350

1474-052

Robertshaw

41-402A

767A-353F

Evcon Coleman025-32625-000 B

41-403B

767A-354A

Goodman B1401009D

41-404B

767A-357F

B1401018C

41-405A

767A-361

A

B1401018SD

41-407B

767A-364

HB Smith50018

A

41-408A

767A-366

Heil

1096048D

41-409B

767A-370B

Hupp Industries09050

A

41-410A

767A-371A

Intercity 1009604

D41-412

D

767A-372A

1096048

41-418C

767A-373D

Majestic 75-92-104A

Snyder General1380654

B 767A-376B

75-92-105

1380672

767A-377A

Metzger 201N

A1380680

767A-382B

201WSuperior Fireplace 94851

AWilliamson

9050A

York025-27766-000

A

025-27774-000025-29043-000025-29050-000

a Table data is correct to the best of Honeywell’s knowledge as of this publication’s date. However, some appliances may have igniter applications that

are beyond the capabilities of this kit.

b For igniters that require bracket A, use the template (Fig. 2 on page 3) to determine the tab to be removed.

c For Carrier sealed combustion furnaces, you must use bracket E and retain the existing orange gasket for use with bracket E.Thermocouple Selector Guide

Specifications

Cross-Reference

Lead Length (in.) Super Tradeline Tradeline White-Rodgers Robertshaw Husky Johnson Controls

18Q340A1066/U Q390A1095/U

H06E-518

K16BT-18K19AT-18

24Q340A1074/U Q390A1046/U

H06E-5241970-24, 1980-24 K16BT-24

K19AT-24

30Q340A1082/U Q390A1053/U

H06E-5301970-30 K16BT-30

K19AT-30

36Q340A1090/U Q390A1061/U

H06E-5361970-36, 1980-36 K16BT-36

K19AT-36

48Q340A1108/U Q390A1103/U

H06E-548

K16BT-48K19AT-48

Thermopile Selector Guide

SpecificationsModel Item Lead Length (in.) Connection Tradeline/Super Tradeline

NotesQ313

Q313A1022/U35

Nut & Spade TerminalTradeline

Q313A1139/U35

Clip & Spade TerminalSuper Tradeline

Push-In Clip

Q313A1170/U35

Clip & Spade TerminalSuper Tradeline

PG9 Adapter (393948)

Q313A1188/U35

Nut & Spade TerminalSuper Tradeline

Push-In Clip, 1/2 in. Attaching Nut

Q313A1055/U47

Nut & Spade TerminalTradeline

1/2 in. Attaching Nut

Q313A1105/B75

Nut & Spade TerminalTradeline

1/2 in. Attaching Nut

ST9120U Universal Electronic Fan TimerST9120U replaces over 41 existing modelsST9101A1014 ST9120C4057 ST9141B1001 ST9160B1035

ST9101A1022 ST9120C5005 ST9150A1003 ST9160B1043

ST9120A2004 ST9120C5013 ST9150B2000 ST9160B1050

ST9120C2002 ST9120D3009 ST9150B2018 ST9160B1068

ST9120C2010 ST9120G2024 ST9150B2026 ST9160B1076

ST9120C2028 ST9120G2032 ST9150B2034 ST9160B1084

ST9120C3000 ST9120G4004 ST9150C4057 ST9160C1000

ST9120C3018 ST9120G4038 ST9160A1002 ST9160C1018

ST9120C4008 ST9120U1003 ST9160B1001ST9120C4016 ST9141A1002 ST9160B1019ST9120C4040 ST9141A1028 ST9160B1027

Honeywell Universal

Replacement Parts

Look For the Blue U

All Honeywell Universal

Replacement Parts feature our

blue U. This means they are

designed to replace a large

number of parts from one or

more manufacturers. You’ll be

ready to replace just about any

part without carrying a large

inventory. By relying on parts

with the blue U, you’ll be able

to do more and carry less.

Universal Pilot Burner

Introducing the Universal Pilot Burner from Honeywell.

The days of replacing pilot burners with like-for-like

products are over.

This is going to be huge. It’s the one design that can be

used on nearly any Honeywell pilot burner you’ll encounter.

So you’ll be able to replace more pilots in less time, and

you’ll be making your calls more profitable.

Like-For-Like Replacements and

Cleanings Have Left the Building

Until now, pilot replacement jobs

have left contractors with two options —

replace pilots with like-for-likeparts

or clean the existing pilot — and

neither option was ideal.

Replacing pilot burners often required

ordering a replacement and returning

to install it later. This left customers

without their needed pilot and you,

the contractor, having to return and

replace a pilot instead of doing more jobs.

Cleaning the pilot takes just as long as

installing a replacement, but it’s only a

short-term fix that increases the likelihood

of a needed callback. Plus, cleaning earns

a fraction of the profits you can make

from replacement. Every time you clean a

pilot, you’re leaving money on the table.

More Gigs, Less Equipment

The Universal Pilot was designed so you’ll

always be confident you have the right

part for the job. You won’t have to spend

time cleaning old pilots or waiting for a

replacement to arrive. You’ll be able to make

the call, replace the pilot and move on to

your next job. The Universal Pilot is loaded

with features that make it the go-to pilot to

stock in warehouses and on your truck.

The Benefits of Stocking

a Universal Line-up

The benefits of the Universal Pilot go

beyond the contractor. Distributors can

count on carrying an inventory that meets

contractors’ needs, is in demand and turns

over sooner. Rather than ordering parts

as they’re needed, or trying to predict

what parts you’ll need with no guarantee

they will be used, you’ll have the right

part for your contractors every time.

No Opening Acts, Just Headliners

The Universal Pilot is the clear choice to make

pilots easier to stock, install and complete

more jobs. Honeywell is making sure you’ll

be able to meet the needs of your customers

immediately and without the profit loss

associated with just cleaning, instead of

replacing, pilots. When you’re ready to start

playing more gigs, with less equipment,

contact your Honeywell representative,

or visit customer.honeywell.com.

THe UniveRsal FiT

The Universal Pilot offers adjustable mounting options, flexible

hood orientations and the accessories needed for replacement.

You’ll have the right fit for almost every situation.

THe CHoiCe FoR ConvenienCe

The universal fittings and compact size of the Universal Pilot

means that instead of carrying a large inventory, contractors

need only carry several Universal Pilots on their trucks to be

prepared for almost any pilot job.

THe TRUsTed Flame

The Universal Pilot was designed to replace nearly any Honeywell

pilot you encounter — over 100, representing 80 percent of pilots

used today. Like all Honeywell Universal Replacement Parts, it was

created so you could do more and carry less.

THe PRoFiT dRiveR

No more pilot cleanings or calling distributors and waiting for the

right replacement pilot to arrive. The Universal Pilot is the right

replacement pilot. Your jobs are done sooner and your profits grow.

THe Time saveR

You can count on having the parts you need, solving your

customers’ problems and maximizing your profit, all with one visit.

Regional sKUs

The Universal Pilot family consists of four SKUs designed to

meet the needs of various geographical regions. Your distributor

will have the Universal Pilot that is right for your area.

Universal Pilot Burner

For Every Job, One Solution

Universal Pilot Burner Brochure #67-7555

Glowfly™ Point-of-Purchase (PoP) Cardboard counter top or shelf display that holds six Glowfly six packs and six single packs.21.75"w x 10.75"d x 11.5" h#67-7338

16

17

Gas Valves

Gas Valves

Gas

Valv

es

ManufacturerPart Number

Honeywell Universal

White Rogers

36C76-459

VR8345Q4563

36C76-460

36C76-461

36C76-462

36C76-464

36C76-467

36C76-468

36C76-469

36C76-470

36C76-471

36C76-472

36C76-473

36C76-477

36C76-478

36C76-479

36C76-480

36C76-482

36C76-483

36C76-484

36C76-485

36C76-486

36C76-487

36C76-534

36C76-535

36C76-907

36C76-913

36C76-927

36C76-935

36C76-936

36C76-942

36C76-958

36C76-961

36C76-969

36C76-970

36C76-971

36C76-972

36C76-977

36C76-978

36C76-982

36C76-983

36C76-984

36C76-985

36E54-201

36E54-208

36E96-201

36E96-205

36E96-206

36E96-224

36E96-261

36E96-301

36E96-302

36E96-303

36E96-304

36E96-305

36H54-400

36H54-401

36H54-402

36H54-403

36H54-418

36H54-420

36H54-421

36H54-470

36H54-471

36H54-472

36H54-485

36H54-486

36H64-301

36H64-302

ManufacturerPart Number

Honeywell Universal

White Rogers

36H64-400

VR8345Q456336H64-401

36H64-402

36H64-403

36H64-404

36H64-405

36H64-463

2E401

VS820M1309

2E854

36C03U-113

36C03U-115

36C03U-273

36C03U-282

36C03U-284

36C03U-285

36C03U-350

36C03U-401

36C03U-403

36C13U-115

36C13U-116

36C13U-117

36C13U-350

SLS521EDB

VR8300M4406

SLS521EDR

SLS521EDRF

SLS525EDR

SLS526DEB

SLS526EDB

SLS521DE

SLS521DEB

SLS525ED3

SLS526DE

Universal SmartValves

Honeywell SmartValves combine gas flow control and

electronic ignition into a single unit providing smart, safe

control in appliances.

SmartValve™

ManufacturerPart Number

Honeywell Universal

Replacement

Armstrong, Concord, AirEase

SV9520H8026

SV9520H8513SV9520H8034

SV9520H8042

SV9520H8067

Burnham

SV9501P2020 SV9602P4832

SV9501P2046 SV9602P4832

SV9501P2087 SV9602P4824

SV9502P2119 SV9602P4832

SV9502P2127 SV9602P4824

SV9502P2135 SV9602P4832

SV9601P4149 SV9602P4832

SV9601P4164 SV9602P4832

SV9601P4172 SV9602P4824

SV9602P4113 SV9602P4832

SV9602P4121 SV9602P4824

SV9602P4139 SV9602P4832

Burnham, ICP, Heil, Tempstar,

Arcoaire, Comfortmaker, KeepRite

SV9501P2004

SV9602P4816SV9501P2053

SV9502P2101

SV9601P4107

SV9602P4105

ICP, Heil, Tempstar, Arcoaire,

Comfortmaker, KeepRite

SV9501M2031

SV9501M2528

SV9501M2049

SV9501M2056

SV9501M2064

SV9501M2080

SV9501M2239

SV9501M2700

SV9501M2718

SV9501M2726

SV9501M2734

SV9501M2742

SV9540Q2464 SV9541Q2561

SV9541Q3098 SV9541Q2561

ICP, Heil, Tempstar, Arcoaire,

Comfortmaker, KeepRite, Mestek,

Slant/Fin

SV9540M2229

SV9641M4510

SV9540M2245

SV9540M2260

SV9540M2278

SV9541M2094

SV9640M3126

SV9640M4116

SV9640M4124

SV9640M4132

Laars, Utica, Armstrong, Concord,

AireEase

SV9501H2409

SV9502H2522SV9501H2417

SV9501H2425

SV9501H3415

SV9501H3423

SV9502H1706

SV9502H2704

Modine

SV9410M2902

SV9510M2511

SV9410M2910

SV9510M2347

SV9510M2354

SV9510M2362

SV9510M2388

SV9510M2412

SV9510M2420

ManufacturerPart Number

Honeywell Universal

Replacement

Roberts Gordon

SV9510H2228

SV9510K2539SV9510K2133

SV9510K2141

SV9510K2158

SV9510K2166

SV9420M2323 SV9520M2536

SV9420M2331 SV9520M2536

SV9501M8103 SV9501M8129

SV9520M2403 SV9520M2536

SV9601M3003 SV9601M4571

SV9601M4167 SV9601M4571

SV9601M4225 SV9601M4571

SV9601P4115 SV9602P4840

SmartValve

SmartValveResidential Combustion

Heating and Cooling Parts

Cross-Reference Guide

Universal Pilot Burner Brochure #67-7555

Disc 1 of 2

7 Modules:

• Basic Hydronic Control Updated! Including Universal Aquastat

• Hydronic Heating Distribution

• Outdoor Temperature Compensation

• Oil Burner Controls Updated! Includes Universal Oil Primaries

• Flame Detection

• Standing Pilot

• Intermittent Pilot Updated! Includes New Universal Ignition Module

Disc 2 of 2

6 Modules:

• SmartValve™

• Direct Burner Ignition

• SmartValve™ Direct Burner Ignition

• Advanced SmartValve™

• SmartValve™ Water Heater Control

• Universal Integrated Furnace Control New Module!

Learn More:

Call toll-free 1-800-328-5111

Email [email protected]

customer.honeywell.com

Automation and Control Solutions

Honeywell

1985 Douglas Drive North,

Golden Valley, MN 55422-3992

63-9357

November 2007

© 2007 Honeywell International Inc.

Heating

Co

ntrols Training

on D

emand

Heating Controls

Training on Demand

HONEYWELL CONFIDENTIAL & PROPRIETARY

f

Heating Controls Training on Demand DVD 63-9357

Page 55: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

55

Notes

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________

Page 56: 2014 Application Selection and Cross-Reference GuideVR8200A2132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kPa) 0˚ to 175˚ F (-18˚ to 79˚ C) None None One One One None VR8200A2744 Standard

Follow us on Twitter: @honeywellcpro

YouTube: @honeywellcpro

Learn More

Call toll-free 1-800-328-5111,

e-mail [email protected] or

visit www.customer.honeywell.com.

Automation and Control Solutions

In the U.S.:

honeywell

1985 Douglas Drive North

Golden Valley, MN 55422-3992

In Canada:

honeywell Limited

35 Dynamic Drive

Toronto, Ontario M1V 4Z9

www.honeywell.com

63-9575 PRAugust 2014© 2014 honeywell International Inc.