148
TEST & MEASUREMENT RENTAL SOLUTIONS GUIDE 2007 VOLUME 32 ISSUE 12 > ELECTRONICS & DATA > ELECTRICAL POWER > GENERAL INDUSTRIAL > ENVIRONMENTAL > CALIBRATION

2007 Rentalsolutionsguide-Aunz Low

Embed Size (px)

Citation preview

Page 1: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my

TEST & MEASUREMENT RENTAL SOLUTIONS GUIDE 2007

VOLUME 32 ISSUE 12

>ELECTRONICS & DATA >ELECTRICAL POWER >GENERAL INDUSTRIAL >ENVIRONMENTAL >CALIBRATION

YOUR TRUSTED PARTNER IN TECHNOLOGY.OFFERING INNOVATIVE SOLUTIONS THROUGH OUR LEADING BRANDS:

RE

NTA

L SO

LUTIO

NS

GU

IDE

2007 TECH

REN

TALS

Page 2: 2007 Rentalsolutionsguide-Aunz Low

TEST & MEASUREMENT RENTAL SOLUTIONS

SpecialiSed equipment

rental

rental purchaSe

OptiOn

expert advice

calibratiOn ServiceS

delivery & Setup

cOnvenient Office

lOcatiOnS

frOm 1 day tO lOng term

Page 3: 2007 Rentalsolutionsguide-Aunz Low

WELCOMEWe are pleased to bring you the 2007 edition of our Rental Solutions Guide, showcasing our extensive inventory of test and measurement equipment covering Data Communications, RF Telecommunications, Electrical Power, Environmental and General Industrial.

TechRentals have been helping solve test and measurement problems for over 32 years and in the past 12 months our organisation has seen significant changes, which have only enhanced our ability to assist. New offices in regional Australia in places like Devonport and Karratha, plus new locations in New Zealand and Malaysia are helping us deliver our solutions to the world.

This new edition of our guide includes numerous new products and models, also highlighting our equipment calibration capabilities via our sister company VMS; Australia’s leading group of NATA certified calibration laboratories.

We look forward to assisting you with your test and measurement needs and hope you will find this guide a useful resource.

The TechRentals Team

TechRentals Information ii Office Locations ivQuick Find Solution Guide vi

>ELECTRONICS & DATA 1General Electronic Test Equipment 2 RF & Microwave 13Low Frequency 26TV Test Equipment 27Data, Network

& Telecommunications 28Cable/Pipe Testers & Locators 36

>ELECTRICAL POWER 39Magnetic Field Meters 40Insulation & Resistance Testers 41Power Quality Analysers 48Projection Relay Testing Systems 57AC/DC Hi Pot Testers 59Electrical Transducers 60Current Injectors - Primary & Secondary 65Power Line Conditioners & UPS 66AC Power 68

>GENERAL INDUSTRIAL 69Data Acquisition & Recording 70Physical Measurement 77Non-Destructive Testing 88General Industrial 94Temperature

& Humidity Measurement 102Security Equipment 106

>ENVIRONMENTAL 109Flow Meters 110Air Conditioning

& Air Quality - HVAC & IAQ 113Occupational Health & Safety 119Gas Analysis & Monitoring 123General Environment 128Laboratory 131

>CALIBRATION 133General Index 135

Page 4: 2007 Rentalsolutionsguide-Aunz Low

TECHRENTALS

Why yOu ShOuld uSe techrentalScOnvenient lOcatiOnSOur customers have access to over 30 TR Corporation locations across Australia, New Zealand and Malaysia. Locations range from small technical offices in remote areas such as Karratha in the mining hub of Western Australia to sophisticated calibration laboratories in Sydney and Brisbane, and our fully equipped TR Corporation headquarters in Melbourne.

vaSt inventOry Of SpecialiSed equipmentWith more than 10,000 items in stock, we’re bound to have the gear you need, no matter what your industry or project. New products are continually being added to our inventory as technology evolves. Local government regulations may apply to the use of some equipment in this catalogue, please contact your local office for more information.

the lateSt prOductS frOm WOrld claSS brandSWe stock the latest gear from leading manufacturers including FLUKE, AGILENT, HIOKI, ANRITSU, MEGGER, YOKOGAWA and more.

expert adviceOur team of technical sales people are highly experienced, most with extensive industry backgrounds. They’re friendly, reliable and knowledgeable with a “can do” attitude.

Simple quOtingOur rapid quoting system means you are only a phone call or “mouse click” away. Get online and select the equipment you need, or call and discuss your specific requirements with our team for a quick and accurate estimate.

flexible rental termSWhether it’s for a day, a week, a year, or you wish to rent-to-own, TECHRENTALS can assist. And if your project is extended, it’s no problem. Simply call and we’ll amend the rental contract.

reSpOnSive delivery & SetupYou need equipment fast and at the right place, at the right time, and ready to go. Equipment is delivered in purpose-built protective containers, in tiptop condition and with easy to understand instructions.

OptiOnSOther options are available to complement your rental needs including data download, trained operators to manage the task for you, customised equipment programming and even total asset management.

nO riSk guaranteeAnd if the unusual occurs and the gear isn’t up to the job, return it within 24 hours to receive a refund on the rental charge.

part Of tr cOrpOratiOnIn 2005, TechRentals became part of a larger family with the formation of TR Corporation. Each subsidiary is a leading brand offering a specialised technology solution for industry. Our group capabilities now include radio communications, audio visual & business equipment, calibration, wireless connectivity solutions and mining communications. Our customers range from mining companies in Poland and Chile to a small electrical contractor in Christchurch, New Zealand - making us a truly global technology supplier.

prOviding SOlutiOnS For 32 years, TECHRENTALS has been providing rental solutions across Australasia. When you need to test, measure or record, we will assist with expert advice, flexible rental options and the right technology to get the job done. When you need the job done right, first time, talk to us.

Page 5: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my

WHY

BUY

WHE

N YO

U CA

N RE

NT?Why yOu ShOuld rent

financial benefitSCONSERVE YOUR CApITAL: Industrial equipment is expensive and can spend much of its time unused, collecting dust and delivering no return on investment. By renting the equipment that you only need occasionally, you can release your organisation’s capital to invest in other parts of the business.RECOVER YOUR COSTS: Generally, rental payments are fully tax deductible, and the expense can be recouped far quicker than tax allowances for ongoing asset depreciation.STREAMLINE YOUR ACCOUNTS: Equipment is often required for a particular client, project or location. Renting allows you to control your financials more effectively and simplifies the process of allocating costs to internal departments or third-parties.WIpE OUT RUNNING COSTS: The expense of maintaining, calibrating and warehousing equipment can be high. By renting equipment, you avoid these costs and potentially free-up valuable space within your premises.

OperatiOnal benefitSTRY bEFORE YOU bUY: It’s not always clear which equipment make and model will fulfil your requirements. A short term rental can give you the hands-on experience you need to guide purchase decisions.KEEp Up WITH THE TIMES: businesses are constantly evolving to keep pace with new technologies. Rental allows you to update your equipment in line with other business and industry changes and avoid the risk of accommodating costly dinosaurs.CATER TO THE UNExpECTED: At peak periods or when essential equipment breaks down, rental can put the necessary equipment in your hands ensuring seamless operations.REFER TO THE ExpERTS: Should you experience difficulties with rented equipment, it’s not your problem. Simply call TechRentals for free professional equipment advice and support.

OptiOn tO OWnTechRentals offers approved business customers a unique rental solution with option to own schemes.Whether it’s the latest power analyser or a humidity chamber, the option of ownership offers flexibility should a stopgap measure turn into a long term or permanent need.After a mutually agreed minimum rental period (typically 12 months), the equipment may be purchased by paying an amount equal to one month’s rental. After a specified number of payments, the equipment is yours!For more information about option to own schemes, please call your local TECHRENTALS office.

delivering benefitSWhether you’re part of a major multinational or a small-to-medium enterprise, equipment rental makes good business sense offering a range of economic and practical benefits.Avoid the headaches and talk to us.

ECONOMICALFLEXIBLE

ACCESSIBLEFree up capitalRecover costs more quicklyControl costs more efficientlyEliminate running costsConduct product research before purchasesApply new technologies & avoid obsolescenceRespond to sudden demandsSeek help from the experts

Page 6: 2007 Rentalsolutionsguide-Aunz Low

v

LOCATIONS

adelaide

81-83 Stephens AvenueTorrensville South Australia 5031P +61 8 8302 8800F +61 8 8302 8899

briSbane

Unit 1 46 Longland StreetNewstead Queensland 4006P +61 7 3850 7700F +61 7 3850 7799

darWin

Unit 3 101 Coonawarra RoadWinnellie Northern Territory 0820p +61 8 8947 2860F +61 8 8947 2901

devOnpOrt

53 Don RoadDevonport Tasmania 7310p +61 3 6422 6000F +61 3 6424 3994

gOld cOaSt

103-105 Spencer RoadNerang Queensland 4211p +61 7 5596 3451F +61 7 5596 4119

karratha

33B Gawthorne DriveKarratha Western Australia 6714P +61 8 9185 6871F +61 8 9441 3999

melbOurne

6 Joseph Streetblackburn North Victoria 3130P +61 3 9896 3000F +61 3 9896 3099

neWcaStle

Unit 2 1 Hartley DriveThornton New South Wales 2322p +61 2 4966 5910F +61 2 4966 3586

perth

122 Kewdale RoadKewdale Western Australia 6105p +61 8 9441 3900F +61 8 9441 3999

pOrt melbOurne

Unit 11 484 Graham StreetPort Melbourne Victoria 3207P +61 3 9896 3000F +61 3 9896 3099

Sydney

Metro Centre Unit 1338-46 South StreetRydalmere New South Wales 2116P +61 2 9933 1100F +61 2 9933 1199

tOWnSville

Unit 8 15-17 Castlemaine StreetKirwin Queensland 4817p +61 7 4773 7788F +61 7 4723 5397

vmS - calibratiOn, repair & ServicemelbOurne

6 Joseph Streetblackburn North Victoria 3130P +61 3 9896 3000F +61 3 9896 3099

cOOperS plainS

Unit 1&4 30 Lensworth StreetCoopers plains Queensland 4108p +61 7 3344 1866F +61 7 3344 1744

milperra

Unit 34 244 Horsley RoadMilperra New South Wales 2214P +61 2 9771 9300F +61 2 9711 9600

auStralia

With locations across Australia, New Zealand and Malaysia, TECHRENTALS have all your Test and Measurement problems covered

Page 7: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my v

auckland

669 Great South Roadpenrose Auckland New Zealandp +64 9 589 2030F +64 9 589 2031

hamiltOn

4/11 pukete RoadTe Rapa Hamilton New Zealandp +64 7 849 0674F +64 7 849 0676

WellingtOn

71 Hutt RoadWellington New Zealandp +64 4 384 4833F +64 4 384 4677

chriStchurch

540 Wairakei RoadChristchurch New Zealandp +64 3 338 1188F +64 3 338 7100

Other tr cOrpOratiOn lOcatiOnS in neW zealand:bearcOm cOmmunicatiOnS

AucklandHamiltonWellingtonChristchurch

vidcOm audiO viSual

AucklandTauranga HamiltonRotoruaChristchurchQueenstownDunedin

kuala lumpur

38 Jalan pJS 11/3 bandar Sunwa46150 petaling Jaya Selangor Darul Ehsan MalaysiaP +60 3 5632 1135F +60 3 5632 5409

penang

b-4-23 Krystal point303 Jalan Sultan Azlan ShahSungai Nibong 11900 Penang Malaysiap +604 642 6318F +604 642 2035

neW zealand malaySia

LOCA

TION

S

Page 8: 2007 Rentalsolutionsguide-Aunz Low

agriculture maintenance & management

chemical analysis 131data logging 70environmental testing 123humidity measurement 113-114light & UV measurement 119liquid & gas flow measurement 110microscopes 82pressure measurement 77, 83temperature measurement 102weather recording 118

air cOnditiOning & refrigeratiOn - maintenance

air conditioning system balancing 118air flow measurement 113-114air quality testing 113-114data logging 70dust detection 113-114gas analysis & monitoring 123gas leakage detectors 118humidity measurement 77, 83liquid & gas flow measurement 110noise analysis 120pressure measurement 82-83temperature measurement 102temperature/humidity/barometric

recording 102vibration measurement 88

autOmOtive engineering & deSign

air flow measurement 113-114air quality testing 113-114data logging 70dc power supplies 7electrical insulation testing 41endoscopes 79force gauges 84gas analysis & monitoring 123high speed video recording 82humidity measurement & recording 102instrumentation amplifiers 73light & UV measurement 119liquid & gas flow measurements 110microscopes 82noise analysis 120non-destructive testing (NDT) 88pressure & vacuum

measurement 82-83tachometers & stroboscopes 78temperature measurement

& recording 102thermal imaging camera 104vibration measurement 88

building & cOnStructiOn

ac power sources/inverters /generators 68

air flow measurement 113-114air quality testing 113-114cable & pipe location 36cable integrity testing 36concrete testing 90-93distance measurement 78electrical insulation testing 41

endoscopes 79gas analysis & monitoring 123hardness testing 93humidity & moisture measurement 105light & UV measurement 119liquid & gas flow measurement 110load measurement 85noise measurement 120non-destructive testing (NDT) 88pressure measurement 82-83security equipment 106temperature/humidity/barometric

recorders 102thermal imaging cameras 104vibration measurement 88weather recording 118

buSineSS & Office equipment

ac generators & UpS 66network test equipment 29security equipment 106

chemical analySiS

air quality measurement 113-114ground water logging 128salinity testing 128spectrophotometers 131water quality testing 128

data cOmmunicatiOnS

ac generators & UpS 66dc power supplies 7fibre optics cable testing & splicing 33LAN analysis and management 29LAN cable testing 32WAN analysis & management 31

defence pOlice fire & emergency

ac generators & UpS 66ac power sources/inverters/

generators 68air flow measurement 113-114air quality 113-114cable pipe testing & location 36data logging 70endoscopes 79environmental - testing 123gas analysis & monitoring 123high speed video capture 82light & UV measurement 119microscopes 82noise & vibraton analysis 120non-destructive testing (NDT) 88sound signal analysis 119spectroscopy 131temperature measurement 102thermal imaging cameras 104TV test equipment 27weather recording 118

educatiOn

security & surveillance equipment 106electrical – induStrial & dOmeStic

ac generators & UpS 66ac power analysis & recording 40ac power sources/inverters/

generators 68

cable pipe testing & location 36current injection 64data logging 70dc power supplies 7digital storage oscilloscope 2electrical calibrators 9electrical transducers 60field strength measurement 19general electrical testing 63high voltage testing 4, 59instrumentation amplifiers 73insulation testing 40magnetic field measurement 40multimeters & electrometers 5power transformers 67temperature measurement 102thermal imaging cameras 104voltage current recording 76

emergency ServiceS

ac generators & UpS 66ac power sources/inverters/

generators 68air flow measurement 113-114air quality 113-114cable pipe testing & location 36data logging 70endoscopes 79environmental - testing 123gas analysis & monitoring 123high speed video capture 82light & UV measurement 119microscopes 82noise & vibraton analysis 120non-destructive testing (NDT) 88RF & microwave testing equipment 13sound signal analysis 119spectroscopy 131temperature measurement 102thermal imaging cameras 104TV test equipment 27weather recording 118

envirOnmental teSting

air flow measurement 113-114air quality measurement 113-114data logging 70electrochemistry 128gas analysis & monitoring 123humidity & moisture measurement 105light & UV measurement 119liquid & gas flow measurement 110noise & sound 120spectroscopy 131temperature measurement 102temperature/humidity/barometric

recorders 102thermal imaging cameras 104vibration analysis 88water quality testing 128weather recording stations 118

event management

metal detectors 107security & surveillance 106

v

QUICK FIND SOLUTION GUIDE

Page 9: 2007 Rentalsolutionsguide-Aunz Low

fOOd manufacturing

air quality monitoring 113-114endoscopes 79high speed video capture 82humidity measurement & logging 102metal detectors 106moisture meters 105process control test equipment 94-95scales & balances 87temperature measurement

& logging 102water quality testing 128

gaS induStry

cable pipe testing & location 36data logging 70gas analysis & monitoring 123high speed video capture 82humidity & moisture measurement 105liquid & gas flow measurement 110non-destructive testing (NDT) 88OH&S & environmental testing

- general 122pressure vacuum gauges

& recorders 82-83spectroscopy 131thermal imaging cameras 104voltage current recording 76

general electrOnicS teSt equipment

data logging 70dc power supplies 7digital storage oscilloscopes 2distortion analysers 26electrical calibrators 9EMC test equipment 21field strength meters & antennas 19frequency counters 12frequency response analysers 10function generators 8instrumentation amplifiers 73LCR meters 9LF signal generators 26logic/analysers/testers 10memory recorders 73multimeters & electrometers 5non-storage oscilloscopes 3probes & accessories 4PROM programmers 10pulse generators 9strip chart recorders 76tape recorders 76TV test equipment 27ultrasonic baths 100voltage current recorders 76

health & Safety

air flow measurement 113-114air quality measurement 113-114data logging 70electrical insulation testing 41electrochemistry 128gas analysis & monitoring 123light & UV measurement 119magnetic field measurement

– Gauss Tesla 40

noise & sound analysis 120OH&S & environmental compliance

testing 122vibration analysis 88water quality measurement 128

it departmentS

ac generators & UpS 66air conditioning testing 113-114air flow measurement 113-114cable location 36data comms test equipment

– LAN/WAN 31security & surveillance equipment 106temperature measurement

& recording 102lOcal gOvernment

ac generators & UpS 66air flow measurement 113-114air quality testing 113-114cable pipe testing & location 36concrete testing equipment 90data logging 70electrical insulation testing 41electrical testers 63electrochemistry 128gas analysis 123LAN analysis & monitoring 29LAN/WAN analysers 31light & UV measurement 119magnetic field meters 40noise & sound analysis 120OH&S & environmental equipment 122temperature measurement 102thermal imaging cameras 104vibration analysis 88WAN analysers 31water quality testing 128

manufacturing & prOceSS induStry

ac generators & UpS 66cable pipe testing & location 36data logging 70distance mesurement 78endoscopes 79gloss mesurement 90hardness testing 93high speed video capture 82humidity & moisture measurement 105inclinometers 84light & UV measurement 119liquid & gas flow mesurement 110materials testing 86, 128, 131memory recorders 73microscopes 82noise & sound analysis 120non-storage oscilloscopes 3OH&S & environmental - general 122position transducers 84pressure & humidity

measurement 77, 83pressure vacuum measurement 82-83PROM programmers 10scales & balances 87

strip chart recorders 76tachometers/stroboscopes 78tape recorders 76temperature measurement 102temperature/humidity recorders 102thermal imaging cameras 104vibration analysis 88

marine

dc & ac power testing 40endoscopes 79liquid & gas flow measurement 110non-destructive testing (NDT) 88see ‘general electronics test equipment’

mining & explOratiOn

ac generators & UpS 66air flow measurement 113-114air quality measurement 113-114cable pipe testers & locators 36data logging 70dc power supplies 7distance measurement & surveying 78electrochemistry 128endoscopes 79force measurement 84gas analysis 123high speed video capture 82humidity & moisture measurement 105inclinometers 84light & UV measurement 119liquid & gas flow measurement 110load measurement 85Logic analysers & testers 10memory recorders 73microscopes 82noise & sound analysis 120non-destructive testing (NDT) 88OH&S & environment compliance

testing 122power analysis & recording 40pressure & humidity

measurement 77, 83pressure vacuum gauges

/recorders 82-83protection relay testing 57RF amplifiers 13RF signal generators 13RF sweep generators 13spectroscopy 131strip chart recorders 76telecommunications testing 21temperature measurement 102temperature/humidity/barometric

measurement 102thermal imaging cameras 104vibration & alignment analysis 88weather monitoring & recording 118

nOn-deStructive teSting

acceleration measurement 88cover meters 92gloss measurement 90hardness testing 93liquid & gas flow measurement 110

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my v

QUIC

K FI

ND S

OLUT

ION

GUID

E

Page 10: 2007 Rentalsolutionsguide-Aunz Low

shock testing 88thickness measurement 90vibration measurement 88

OccupatiOnal health & Safety

air flow measurement 113-114air quality measurement 113-114data logging 70electrical insultation testing 41electrochemistry 128gas analysis & monitoring 123light & UV measurement 119magnetic field measurement

– Gauss Tesla 40noise & sound analysis 120OH&S & environment compliance

testing 122vibration analysis 88water quality measurement 128

petrOchemical

data logging 70electrochemistry 128force measurement 84gas analysis & monitoring 123high speed video capture 82liquid & gas flow measurement 110load measurement 85memory recorders 73microscopes 82non-destructive testing (NDT) 88pressure & humidity

measurement 77, 83pressure vacuum gauges

/recorders 82-83strip chart recorders 76tachometers/stroboscopes 78temperature measurement 102thermal imaging cameras 104vibration & alignment analysis 88water quality measurement 128

plumbing & gaSfitting

see ‘water waste water & plumbing’ section pOWer generatiOn & diStributiOn

cable pipe testers & locators 36combustion gas analysis

& monitoring 124-125current injectors 64data logging 70distance measurement & surveying 78endoscopes 79force measurement 84hi pot testing 59high speed video capture 82humidity & moisture measurement 105inclinometers 84insulating testing 41LCR meters 9liquid & gas flow measurement 110load measurement 85magnetic field measurement

– Gauss Tesla 40noise & sound analysis 120non-destructive testing (NDT) 88

power analysis & recording 40protection relay testing 57strip chart recorders 76tachometers/stroboscopes 78temperature/humidity/barometric

measurement 102thermal imaging cameras 104vibration & alignment analysis 88voltage current recorders 76weather monitoring & recording 118

quality cOntrOl

see ‘manufacturing & process industry’ section refrigeratiOn

see ‘air conditioning & refrigeration’ section retail

security & surveillance equipment 106rf & micrOWave

communications test sets 21EMC test equipment 21field strength meters & antennas 19filters 26frequency counters 12logic analysers & testers 10modulation meters 20power meters 22RF amplifiers 13RF signal generators 13RF sweep generators 13spectrum analysers - high frequency 14telecommunications testing 21TV test equipment 27

rOad rail & civil cOnStructiOn

ac power sources/inverters /generators 68

air flow measurement 113-114air quality measurement 113-114cable pipe testing & location 36concrete testing equipment 90-92dc power supplies 7distance measurement & surveying 78electrochemistry 128force measurement 84gas analysis & monitoring 123hardness testers 93inclinometers 84load measurement 85magnetic field measurement

– Gauss Tesla 40noise & sound analysis 120non-destructive testing (NDT) 88power analysis & recording 40vibration & alignment analysis 88water quality testing 128weather monitoring & recording 118

Security & crOWd crOntrOl

bug detectors 106CCTV 106metal detectors – person

& walk thru 106surveillance equipment 106thermal sensing cameras 104

telecOmmunicatiOnS

distortion analysers 26fibre optics testing & splicing 33frequency counters 12LAN/WAN analysis 31logic analysers & testers 10pulse generators 9RF & microwave 13RF amplifiers 13RF signal generators 13RF sweep generators 13WAN analysers 31

training

security & surveillance 106tranSpOrt

automotive general testing 90data logging 70dc power supplies 7distance measurement 78endoscopes 79load measurement 85noise & sound analysis 120non-destructive testing (NDT) 88scales & balances 87thermal imaging cameras 104vibration & alignment analysis 88

travel & leiSure

metal detectors 106-107security equipment 106

Water WaSteWater & plumbing

data logging 70distance measurement & surveying 78electrochemistry 128endoscopes 79gas analysis & monitoring 123inclinometers 84liquid & gas flow measurement 110pipe locators 36water quality testing 128

WOrkplace envirOnment

air flow measurement 113-114air quality measurement 113-114data logging 70electrical insulating testing 41electrochemistry 128gas analysis & monitoring 123

v

QUICK FIND SOLUTION GUIDE

Page 11: 2007 Rentalsolutionsguide-Aunz Low

ELECTRONICS & DATA

Page 12: 2007 Rentalsolutionsguide-Aunz Low

2

GENERAL ELECTRONIC TEST EQUIPMENT

Tektronix TDS2014 100MHz 4 Channel Colour DSOTEK,TDS2014 AUSampling rate 1GS/s. Sensitivity 2mV~5V/div. bandwidth limited to 20MHz when set to <5 mV/div. Automatic waveform measurements include period, frequency, + width, - width, rise time, fall time, max, min, peak to peak, mean and RMS. Includes FFT Analysis as standard, TDS2CMA GpIb & RS232 interfaces.Tektronix TPS2014 100MHz 4 Channel PowerscopeTEK,TpS2014 AUSampling rate 1GS/s. All 4 channels isolated for floating measurements. Sensitivity 2mV~5V/div. bandwidth limited to 20MHz when set to <5mV/div. Measurements for current and voltage distortion and their spectral content, harmonics, instantaneous power, power factor and switching loss. Automatic waveform measurements include period, frequency, +width, -width, rise time, fall time, max, min, peak to peak, mean & RMS. Includes FFT Analysis as standard. power analysis package, low & high voltage power probes (p5120 probes: dc to 200MHz, 1,000Vrms etc). battery operation.

Tektronix TDS2024 4 Channel 200MHz Colour DSOTEK,TDS2024 AUSampling rate 2GS/s. Sensitivity 2mV~5V/div. bandwidth limited to 20MHz when set to <5 mV/div. Automatic waveform measurements include period, frequency, +width, -width, rise time, fall time, max, min, peak to peak, mean and RMS. Includes FFT Analysis as standard, TDS2CMA GpIb & RS232 interfaces.

Tektronix TDS3052B 2 Channel 500MHz DSOTEK,TDS3052b AUSampling rate 5GS/s. Memory length 10k. Sensitivity 1mV~10v/div. Time base 1ns~10s/div. Trigger functions include video. Automatic waveform measurements. FFT Analysis. Wave alert & e-scope web based control. Colour LCD with digital phosphor function. Centronics, GpIb (IEEE-488), Ethernet, and RS232 interfaces. In-built FDD.Tektronix TDS3054 500MHz 4 Channel DSOTEK,TDS3054 AU/NZSampling rate 5GS/s. Memory length 10k. Sensitivity 1mV~10V/div. Time base 1ns~10s/div. Trigger functions include logic, advanced video, pulse width & glitch, plus slew rate. Automatic waveform measurements. Colour LCD with digital phosphor function. FFT, integration and differential functions. Centronics, GpIb (IEEE-488) & RS232 interfaces. TDS3FFT (FFT analysis module) & TDS3TRG (advanced trigger module) included. In-built FDD.

>NEW Tektronix DPO4054 4 Channel Memory scope

TEK,DpO4054 AUWave Inspector® controls, delivers the performance you need to visualize even your most demanding signals. 10 Megasample record length on all channels.

digital StOrage OScillOScOpeS

Model Channels Bandwidth(MHz) Sampling Features Interfaces

TEK,TDS2014

4

100 1GS/sColour, automatic measurements. TDS2CMA,

GPIB, RS232TDS,TpS2014 Colour, battery operated, automatic & power measurements

YEW,DL1540L 150 200MS/s Inbuilt printer and FDD. FFT. 1.2Mb memory (2, 4 ch).FFT and GO/NOGO waveform functions. GPIB

TEK,TDS2024 200 2GS/s Colour, automatic measurements, FFT TDS2CMA, GPIB, RS232

TEK,TDS3052/b 2

500 5GS/s

Extensive automatic measurements. Inbuilt FDD. Centronics, RS232, GPIB

TEK,TDS30544 Extensive automatic measurements. Inbuilt FDD.

Some assets include FFT, advanced trigger modules.Centronics,

RS232, GPIBTEK,TDS3054b

TEK,THS720A

2

100 500MS/s AC/DC battery portable. Multimeter functions.

TEK,THS730A200

AC/DC battery portable. Multimeter functions.

FLU,199C-SCOPEMETER 2.5GS/s Colour, DMM, auto screen capture, electrical power measurements, PC software.

FLU,196 2 100 1GS/s Colour, DMM, auto screen capture

Hp,6104A 4 1,000 4GS/s 16 channel logic analyser, serial trigger, usb, i2C, SpI, LIN, CAN, HDTV with LAN, USb, GpIb, VGA interfaces

TEK,WAVESTAR Software for Tektronix oscilloscopes.Acquires and exports to common applications.

Page 13: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 3

GENE

RAL

ELEC

TRON

IC T

EST

EQUI

PMEN

T

Tektronix TDS3054B 500MHz 4 Channel DSOTEK,TDS3054b AU/NZSampling rate 5GS/s. Memory length 10 k. Sensitivity 1 mV - 10 v/div. Time base 1ns~10s/div. Trigger functions include video. Extensive automatic waveform measurements. Including FFT, TV trigger, advanced analysis (TDS3AAM), and limit testing (TDS3LIM). Colour LCD with digital phosphor function. VGA, GpIb (IEEE-488) & RS232 interfaces included (TDS3GV). In-built FDD. Comes with TDS3bATb for battery operation.

Tektronix THS730A 200 MHz Battery DSOTEK,THS730A AUDual channel battery portable digital storage oscilloscope with digital multimetre facilities. Max sampling rate 1GS/s. Suited to high voltage applications depending on probe selection. Max input 640V rms, max float 600Vrms. Waveform processing including watts calculations. Video trigger. RS232 interface. Use TEK,WAVESTAR software for pC interface.Tektronix Wavestar Software for TDS DSOTEK,WAVESTAR AUAcquires, prints, and exports waveforms and screen images as graphics images or data values. Exports to common packages, eg. MS Word, Excel. Obtains data via RS232, GPIB and FDD.Yokogawa DL1540L 150MHz 4 Channel DSOYEW,DL1540L AU/MYIn-built printer & FDD. Amplifier bandwidth 150MHz. Sampling rate 200MS/s. Sample memory of 2Mword for 2 channels & 1Mword for 4 channels. bMp, TIF HpGL, postscript & comma separated waveform formats. GO/NOGO testing of waveforms. External sample rate input - useful for rotating machinery work. Waveform computations including FFT. Averaging function to reduce the S/N ratio, accumulate function. GpIb interface.Fluke 196 100MHz 2 Channel Portable ScopemeterFLU,196 NZReal-time sampling 1GS/s per input. Connect & view automatic triggering, a full range of manual trigger modes plus external triggering. 27,500 points per input record length using Scoperecord™ mode. Automatic capture and replay of 100 screens. Automatic waveform measurements 24. Cursors, zoom and real-time clock. 1kV independently floating isolated inputs. Includes a 5000 count true-rms multimeter and a Trendplot™ paperless recorder.

Fluke 199C Scopemeter 200MHz Hand-heldFLU,199C-SCOpEMETER AUFLU,199 NZColour digital oscilloscope, 200MHz bandwidth, 2 channel with DMM feature. Colour display 14.4cm with persistence feature. Real time sampling 2.5GS/s. Input sensitivity 5mV/div~100V/div. Glitch capture 3ns using pulse width triggering. Timebase range in scope mode 5ns/div~2min/div. Trigger types auto, free run, single shot, edge, delay, video, video line, selectable pulse width & external. Automatic capture and replay of last 100 screens. Measures electrical power properties such as VA, VAR, etc. Inputs are isolated (1kV CAT II/600V CAT III). pC software. battery operation 4h.

HP/Agilent MSO6104A 1GHz Digital Oscilloscope with LogicHp,6104A AUAgilent 6104A 1 GHz 4 + 16 channel mixed signal oscilloscope (MSO). 4Gsa/s. xGA Colour display updates 100,000 waveforms/sec with 256 levels intensity. 4 analogue channels and 16 logic channels. Deep memory. 8 digit frequency counter function. Triggering includes video, HDTV, I2C, SPI, LIN, CAN, and USb. FFT analysis included. LAN, USb, GpIb, & xGA interfaces standard.

digital StOrage OScillOScOpeS

Tektronix 2205GM 40MHz Dual Trace OscilloscopeTEK,2205GM AUVertical sensitivity 5mV/div~5V/div. Timebase 0.1µs~0.5sec/div x10 magnifier. TV line and field trigger.

Tektronix 300MHz Portable Oscilloscope 4 ChannelTEK,2465 AU2mV~5V/div. Dual timebase with delayed sweep, 500ps~0.5s/div. 50Ω & 1mΩ input impedance.

nOn-StOrage OScillOScOpeS

Page 14: 2007 Rentalsolutionsguide-Aunz Low

4

GENERAL ELECTRONIC TEST EQUIPMENT

Model Type Bandwidth Attenuation Voltage Max Current Max (A)FLU,80K-40

Voltage high

DC~100MHz 1:1,000 40kV dc, 28kV ac

MET,HT212-30KDC DC 1:100 30kV dc

TEK,P6015 75MHz 1:1,000 40kV

COL,HV40b dc to 300Hz 1,000:1

ACR,SI9000 Voltage isolation 15MHz 1:20, 1:200 700V

bEL,CG-100A Current clamp-on AC DC dc~1kHz 660 rms 100

TEK,p6302-CT5 Current clamp-on 20 MHz 50K

TEK,P6158 Passive probe 30GHz 1:20

TEK,5200 Differential probe dc to 25MHz 1300VSee also Electrical Transducers

prObeS and acceSSOrieS

Agilent 82357A GPIB/HPIB/IEEE488 to USB interfaceHp,82357A AUAllows all GpIb/HpIb/IEEE488 equipment to controlled from any USb equipped pC (not MACs). Drivers for pC. Separate software may be required for equipment being controlled.Fluke 80K-40 High Voltage ProbeFLU,80K-40 AU1~40kV dc or peak ac, 28kV ac rms. Input resistance 1GΩ, division ratio 1,000:1. Note: input impedance of DVM must be 10MΩ or reading will be wrong.

Acree SI9000 Differential ProbeACR,SI9000 AUInput probe for converting oscilloscopes, etc, to floating input for power measurements, etc. Input attenuation 1/20 & 1/200 with 2MΩ impedance to earth. bandwidth dc~15MHz. Max input 700Vac. Input range up to 700Vdc in 1/200 mode. battery operated.Bell CG-100 A Clip-on Current GunbEL,CG-100A AUCurrent range dc, ac 10A~100A. DC~1kHz, accuracy 2%, 100% overrange capacity, clamp ¾“Ø, 30h battery operation, IV output for oscilloscope.

National Instruments GPIB-USB Interface with Plotter SoftwareNAT,GpIb-USb-HS AUHigh speed GpIb to USb interface. provides control of GpIb/HpIb/IEEE488 devices from a USb equipped pC (requires Win 2000 or later operating system). Includes software to allow PC to emulate a GPIB plotter. Plotter software outputs plots as HpGL, HpGL/2, JpEG, TIFF, bMp & WMF. plotter software can emulate Hp 7440, Hp 7470, Hp 7475, Hp 7550 & Hp 7570 pen-plotters.Tektronix P5200 Isolated Differential ProbeTEK,P5200 NZHigh voltage differential probe to provide a safe means of measuring circuits with floating potentials up to 1kV from earth to ground and up to 1,300V differential. Range settings are 1/50 & 1/500. bandwidth: dc to 25MHz accuracy is ±3%, input impedance is 8MΩ, 3.5 pF between inputs. Rise time is 14ns.Tektronix P6158 Passive RF Probe dc 3GHz 20XTEK,p6158 AUAttenuation dc~3GHz 20x. Input resistance 1kΩ.Tektronix P6015 40kV High Voltage ProbeTEK,p6015 AUbandwidth 75MHz. Input rating: 40kV pulse, 20kVdc plus peak ac. Derating with frequency applies. Input impedance 100MΩ. Attenuation x 1000.USB to RS232 ConverterUSb,232CONVERTER AUStackable expansion module that connects to a pC or server via the USb port. provides 1 high speed RS-232 serial port. System Requirements; pentium class, USb type A, Win 98, ME, 2000, xp, MAC 8.6 & later.

Page 15: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 5

GENE

RAL

ELEC

TRON

IC T

EST

EQUI

PMEN

TmultimeterS and electrOmeterS

Model Type Application Scale (digit) Interface True RMS Max (V)FLU,177

FLU,189

HIO,3256-50 Digital HiTester multimeter General 6 No 1,000

HIO,3805 Multi Function Digital Multimeter

MET,Mx44

Multimeter

MET,Mx53General

4½ 1,000MET,Mx54

Yes

MET,Mx51Ex Intrinsically safe

FLU,87

FLU,87-2

Hp,3400A RMS voltmeter Audio/RF Analogue Analogue output 300

FLU,8010A

MultimeterGeneral

1,000

LEM,UNIGOR355 4¾IR interface Yes

LEM,UNIGOR380 6

Hp,34401A6½

RS232/HpIb

Hp,3455A-NATA Precision HPIB Yes

GOS,METRAHIT-29S powermeter - TRMS Multimeter Precision ±310,000 count IR interface Yes CAT III 600

SIM,SS2x Charge measurement Electrostatic Analogue 200 kV/m

MMM,709 Electrostatic meter Static voltage 4 No 8,000

>NEW Fluke 87-2 Digital Insulation Multimeter

FLU,87-2 MYA combined digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

>NEW Fluke MultiMeter with Backlight

FLU,177 AUGeneral purpose multimeter. True RMS voltage and current measurements, digital display with analog bargraph and backlight, manual and automatic ranging, display Hold and Auto Hold, frequency and capacitance measurements. Overvoltage category EN61010-1 CAT III 1000V/CAT IV 600V.

Page 16: 2007 Rentalsolutionsguide-Aunz Low

6

GENERAL ELECTRONIC TEST EQUIPMENT

>NEW Fluke Logging Multimeter

FLU,189 AUHigher end multimeter. PC interface for data exchange, internal memory allows stand-alone logging of up to 1000 measurements. Extremely fast readings true RMS AC + DC measurements, 100kHz ac bandwidth for voltage and current, dual display with bargraph and two-level backlight, min/max/average with real time clock and 250µs Fast Min-Max, Temperature measurement -200ºC~1350ºC, dbV/dbm with selectable reference. Overvoltage category EN 61010-1 (IEC 1010-1) CAT III 1000V/CAT IV 600V.

>NEW Hioki 3805 Multi Function Handy Type Digital Multimeter

HIO,3805 AU9999 count display full scale for voltage range. Optional RS232C package for transferring data to a PC, True rms rectified, easy harmonic distortion check function, simultaneous 2-point temperature measurement, maximum, minimum, average value display, 4~20mA measurement value convert to 0-100 % display, for maintaining and serving industrial meter. Meets CAT III 600V requirements and CAT II 1kV requirements.

Gossen Metra Hit 29S Powermeter - TRMS MultimeterGOS,METRAHIT-29S AUHigh Precision Digital Multimeter

Hioki 3256-50 Digital Multimeter CAT II 1kV & CAT III 600VHIO,3256-50 AUHioki 3256-50 Digital HiTester Multimeter, CAT II 1000V and CATIII 600V AC/DC, Current 10A AC/DC.

Metrix MX54 Digital MultimeterMET,Mx54 AUMeasures ac/dc voltage and current, resistance, frequency, and capacitance. 4½ digit display giving a sensitivity of 10µV & 10nA. Ranges: voltage 500mV~1,000V (750V ac), current 500µA~10A, resistance 500Ω~50MΩ with a max resolution of 10mΩ, frequency; 0.6Hz ~500kHz; db measurement over impedance range 1~9,999Ω.Metrix MX55 TRMS MultimeterMET,Mx55 MYTrue rms digital multimeter measuring ac/dc voltage & current, resistance, frequency. 4.5 digit display.Metrix MX51EX Intrinsically Safe Digital Multimeter MET,Mx51Ex AUResolution 5,000 count with 0.1% basic accuracy. Measures ac/dc voltage and current, and resistance. Voltage sensitivity 100µV. Max voltage 1kV dc, 750Vac. Max current 10A. Intrinsic safety limits of 60V & 500mA.Metrix MX53 Hand Held Digital MultimeterMET,Mx53 AUDisplay 50,000 count with 34 segment bar graph. Vdc range 500mV~1kV. Vac range 500mV~750V. Current range 500µA~10A. Resistance range 500Ω~50MΩ. Capacitance range 50nF, 50mF. Frequency range 0.6Hz~500kHz. Min & max value mode. Continuity and diode checking functions.HP 3400A ac True rms 10MHz Analogue VoltmeterHp,3400A AUAnalogue display 10Hz~10MHz, 1mV~300V FS. Recorder output. Fluke 87 Digital MultimeterFLU,87 NZHandheld digital multimeter. Measures ac/dc voltage, current and resistance. peak hold feature.LEM Unigor 355 Hand-held Digital Multimeter/Signal GeneratorLEM,UNIGOR355 AUMeasures dc, ac trms voltage & current, resistance, frequency, capacitance, temperature & time. Display 4¾ digit. Resolution 10µV, 10nA, 10mΩ, 1pF & 0.01Hz. Ranges voltage 300mV~1kV, current 300µA~10A, resistance 300Ω~30MΩ, frequency 300Hz~100kHz, db -48~63, temperature ºC/ºF, pt 100 -200~100ºC, pt 1000 100~850ºC. Features automatic socket shutters, IR interface, split second chronograph, automatic measurement value storage, etc. LEM Unigor 380 Digital MultimeterLEM,UNIGOR380 AUPrecision 6 digit multimeter. Measures dc, ac trms voltage & current, resistance, frequency, capacitance, temperature & time. Resolution 1µV, 1nA, 1mΩ, 1pF & 0.001Hz. Ranges voltage 300mV~1kV, current 300µA~10A, resistance 300Ω~30MΩ, frequency 300Hz~300kHz, db -48~63, temperature ºC/ºF K -200~1,372ºC, J -210~1200ºC. Features automatic socket shutters, IR interface, split second chronograph, automatic measurement value storage, etc.HP 34401A Digital MultimeterHp,34401A AUprecision 6½ digit multimeter. 100nV sensitivity on dc 120mV range. Max dc input 1kV. Measures ac voltage, dc & ac current to 3A, 2 or 4 wire resistance to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths functions including limits test. 512 point storage. RS232 and HPIB interfaces.Keithley 2503 Static Detector Probe KEI,2503 AUDetects voltage due to charge on small surface areas. Used at a distance of 6mm from a surface having a charged plane of at least 13mmØ.Simco SS2X Electrostatic Charge Meter (Analogue)SIM,SS2x AUDesigned for detecting and measuring the voltage and field strength associated with static charges on objects and materials. Capable of measuring voltages from 0 ~200 KV and field strength from 0~4000MV/M3M 709 Electrostatic MeterMMM,709 NZDigital electrostatic meter. Reads 20kV at 25mm distance, accuracy ±10%. 2 volt recorder output.

multimeterS and electrOmeterS

Page 17: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 7

GENE

RAL

ELEC

TRON

IC T

EST

EQUI

PMEN

T

Model Current Max (A) Voltage (Vdc) Dual Variable

Hp,E3640A 3, 1.5 8, 20Yes

No

LAb,622 230

Yes

RED-30V-30A 30 No

bWD,246A 5 36 Yes

TRI,pD35-20 20 35

SOR,DCR10-120b 120 10

SOR,DCR600-3b 3 600

SOR,DCS60-50

50

60

AUS,AD2K548

No

INV,MpS48DC2400W

YesTRI,pD35-10D 10 35

xAN,xKW60-50 50 60

dc pOWer SupplieS

BWD 246A Dual Power Supply bWD,246A AUDual output 0~36V, 0~5A per section. Use in series, parallel or tracking modes.Trio PD35-20 DC Power Supply TRI,pD35-20 AUOutput 0~35V, 0~20A. Constant current, constant voltage. Multiple parallel or series operation. Remote programming of voltage or current by external voltage or resistance.Ausmode AD2K5 48V 50A RectifierAUS,AD2K5 AUDC rectifier (power supply), 50A @ 48V. Voltage not adjustable. Use to power telecoms and other battery supported equipment.Agilent E3640A Programmable DC Power SupplyHp,E3640A AU30W single-output programmable power supply with built-in GpIb and RS232 connectivity and SCpI language compatibility. 0~8V/3A or 0~20V/1.5A. Over-voltage protection and remote sensing. Low noise and excellent regulation. Front and rear output terminals.

Lab 622 Dual 0~30Vdc DC Power SupplyLAb,622 NZAdjustable current limit of 0~2A dc.Redfern 30V / 30A Power SupplyRED,30V-30A NZAdjustable current trip from 0~30V. Voltage and current meters.Sorensen DCR10-120B dc Power SupplySOR,DCR10-120b AU/MY0~10V, 0~120A.

Sorensen DCR600-3B dc Power SupplySOR,DCR600-3b AU0~600V, 0~3A.

Sorensen DCS60-50, 60V 50A dc Power SupplySOR,DCS60-50 AU0~60V, 0~50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph 240V supply. On 1ph 50V @ 50A or 60V @ 42A. Remote programming.Trio Kenwood PD35-10D 35V 10A Power SupplyTRI,pD35-10D AUOutput 0~35V, 0~10A. Constant current, constant voltage. Multiple parallel or series operation. Remote programming of voltage or current by external voltage or resistance.Invensys Intergy Mini Power System 48V dc 2.4kW SupplyINV,MpS48DC2400W AUSub-rack Mini System 19” rack mount range. Ideal solution for low power telecommunications applications (premises Data Networks and Ip Routers, Local Loop Transmission Systems and Wireless) requiring compact, efficient and flexible dc power supplies. Includes an integral dc distribution panel and an SM30 Series Intergy Supervisory Module. All system settings are fully adjustable in software. Input: R1148: 220/240Vac, 50/60Hz (nominal). power factor: >0.98 @ 30~100% max system current. Efficiency: >89%. Output; voltage 48V, 45~60Vdc, current @ 48Vdc 50A (2400W). Dimensions: 133H x 275W mm overall. Weight: 12kg typical configuration.Xantrek XKW60-50 60V 50A dc Power SupplyxAN,xKW60-50 AU0~60V, 0~50A. Constant current and constant voltage. Analogue programming. Operation of multiple units in series or parallel.

Page 18: 2007 Rentalsolutionsguide-Aunz Low

8

GENERAL ELECTRONIC TEST EQUIPMENT

functiOn generatOrS

Model Special features Frequency Max (MHz) Frequency Min (µHz) Voltage Max Arbitary

HP,3325B High stability & accuracy 21 MHz 1

10Vp-p YesHp,33120A 15 MHz 100

Hp,33220A 20MHz1

Hp,33250A 80 MHz

>NEW Tektronix 3022/25MHz Arbitrary Function Generator

TEK,AFG3022 AUDual channel function/arbitrary waveform generator. Frequency range1mHz ~25MHz sine, 12.5MHz square & pulse waveforms, 250 kHz triangle, ramp, noise & DC waveforms. Arbitrary waveform generation 12.5MHz. Gaussian noise to 25MHz. Output into 50Ω 10mV~10V p-p. AM, FM, FSK, and burst modulation. HpIb, USb, & LAN interfaces used with included software allows waveforms to be created on PC and imported into unit. Full screen display also allows display and editing of waveforms on unit itself.

>NEW Tektronix 3102/100MHz Arbitrary Function Generator

TEK,AFG3102 AUDual channel function/arbitrary waveform generator. Frequency range 1mHz~100MHz sine, 12.5MHz square and pulse waveforms, and 250kHz triangle, ramp, noise, and DC waveforms. 12.5MHz Arbitrary waveform generation. Gaussian noise to 25MHz. Output into 50ohms 10mV~10V p-p. AM, FM, FSK, and burst modulation. HpIb, USb, and LAN interfaces used with included software allows waveforms to be created on PC and imported into unit. Full screen display also allows display and editing of waveforms on unit itself.

Agilent 33220A 20MHz Function/Arbitrary GeneratorHp,33220A AUFunction/arbitrary waveform generator. Frequency range 20MHz sine & square waveforms, 200kHz pulse, triangle, ramp, noise, and DC waveforms. Gaussian noise to 10MHz. Output into 50Ω 10mV~10V p-p. AM, FM, FSK, and burst modulation. Includes option 001 external timebase reference. With optional benchlink software waveforms can be captured and played back. HpIb, USb, & LAN interfaces.

HP 33120A Function/Arbitrary GeneratorHp,33120A AU/MYFrequency range 15MHz sine & square waveforms, and 100kHz triangle & ramp waveforms. Gaussian noise to 10MHz. Output into 50, 50mV~10V pp. AM, FM, FSK, and burst modulation. Optional benchlink software allows waveforms to be captured and played back. HpIb & RS232C interfaces. Some assets include option 001 phase lock and high stability TCxO timebase - input & output 10MHz with phase offset.

HP 33250B Synthesized Function GeneratorHp,3325b AUSine frequency range 1µHz~21MHz, square wave/triangle/ramps to 11MHz. Sweep generator function. In-built modulation generator which includes arbitrary waveforms with arbitrary, sine, and square wave outputs. Output phase can varied with 0.1O resolution and multiple units can be locked together for variable phase output signals. Very high amplitude resolution and setting accuracy.HP/Agilent 33250A 80MHz Function/Arbitrary Waveform GeneratorHp,33250A AUFrequency range 80MHz sine & square waveforms. 50MHz pulse waveforms with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz triangle & ramp waveforms. White noise to 50MHz. Output into 50Ω 10mVpp~10Vpp. AM, FM, FSK, and burst modulation. Intuilink software for programming arbitrary waveforms. HPIB & RS232C interfaces.

Page 19: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 9

GENE

RAL

ELEC

TRON

IC T

EST

EQUI

PMEN

T

HP 8012B Pulse GeneratorHp,8012b AUpulse generator 1Hz~50MHz. Variable transition times down to 5ns. Amplitude +10V with selectable source impedance. pulse width 10ns~1s. External trigger and gate.

pulSe generatOrS

Stanford Research SR1720 LCR BridgeSR,SR720 AUAutomatic LCR bridge with 0.05% accuracy. Ranges: inductance 0.0001µH~99,999H; capacitance 0.0001pF~99,999µF; resistance 0.0001Ω~2,000MΩ. Also measures Q & D. Test frequencies 100/120Hz, 1/10/100kHz. Indicates value, deviation, % deviation, or bin number. DC bias internal 0~2V, external 0~40V. Complete with optional Kelvin leads.

Tegam 3550 45Hz-5MHz Programmable LCR MeterTEG,3550 AUprogrammable Impedance/LCR Meter. User selectable test frequency from 42.0Hz~5.00MHz. 18mS measurement speed. 0.10% basic accuracy. Fully programmable with18 measurable parameters and absolute or percentage comparator. Binning function supports 10 output bins. Output to 3 highly visible LED displays. Standard RS232C & I/O interfaces

lcr meterS

>NEW Genrad 1433-20 Decade Resistor

GR,1433-20 MYResistance range from 1mΩ~111MΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature coefficient, 5 ppm/°C. Good frequency characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero resistance (<1 mO per decade). May be used for RTD simulation. Rack mount option.

Genrad 1432T Decade resistance boxGR,1432T AUTen steps of the following: 0.01Ω, 0.1Ω, 1Ω, 10Ω, 100Ω. Maximum resistance 1KΩ.

Genrad 1433B 1.1 m 6 Decade Resistance Box - NATAGR,1433b-NATA AUSix decades by 1Ω~1.1MΩ, accuracy 0.01%. NATA calibrated.Genrad 1433F 111 K 7 Decade Resistance Box - NATAGR,1433F-NATA AUSeven decades by 0.01Ω~111KΩ, accuracy 0.01% +0.002Ω. Useful for platinum resistance thermometer calibration. NATA calibrated.Danbridge DR60 Decade Resistor ResistanceDAN,DR60 MYDecade Resistor. Maximum 10kΩ. Smallest resolution 0.01Ω.Yokogawa 2553 dc Voltage/Current StandardYEW,2553 AU/MY1µV~12V, 0.1µA~120mA, accuracy ±0.02%, power 240V/50Hz.Yokogawa 2554 Portable dc Voltage/Current StandardYEW,2554 AU10mV, 100mV, 1V, 10V, 100V, 1mA, 10mA, 100mA, ±0.05% accuracy. Internal battery or mains operation.

Model Type Description Accuracy %DAN,DR60 Resistance box Decade resistance box

GR,1433-20 Resistance Box Decade resistance box

GR,1433b-NATA Resistance box 1~11.1MΩ Decade resistance box. 6 decades x 1Ω0.01

GR,1433F-NATA Resistance box 0.01Ω~11kΩ Decade resistance box. 7 decades x 0.01Ω

YEW,2553 DC voltage & current standard 0.02

YEW,2554 Portable DC voltage & current standard 0.05

electrical calibratOrS

Page 20: 2007 Rentalsolutionsguide-Aunz Low

10

GENERAL ELECTRONIC TEST EQUIPMENT

>NEW Protek 3290 RF Analyser/Signal Meter 2.9GHz

pRO,3290 AURF signal analyser and level meter. Provides spectrum display up to 2.9 GHz, audio output, level measurement, and frequency measurement. Inbuilt antenna. Frequency range 100 kHz to 2.9GHz with frequency steps from 5 kHz. Modulation types narrow and wide band FM, AM, and SSb. Level measurement minimum frequency - narrow band FM 1 MHz, wide band FM, AM, SSb 10 MHz. bandwidth - narrow band FM 12.5 kHz, wide band FM 180 kHz, AM & SSb 2.4 kHz. Input impedance 50 ohms.

HP 1662A 68 Channel Logic AnalyserHp,1662A AU/MYTiming analysis 250MHz all channels, 500MHz half channels. Transitional: 125MHz all channels, 250MHz half channels. Glitch: 125MHz half channels. State analysis to 100MHz on all channels. Memory 4k/channel, 8k/channel in half-channel modes. 4 clock channels available. HpIb & RS232C ports. In-built DOS format FDD used to load inverse assemblers and transfer measurement data to a computer. Compatible with most HP preprocessors and inverse assemblers.

>NEW Agilent/HP 1652B 80 Channel Logic Analyser

Hp,1652b AU80 channels, maximum conventional timing rate 100 MHz, transitional timing rate 100MHz & glitch timing rate 50MHz. Memory depth/channel-normal 1Kb. Channel to channel delay 4ns. Minimum recognizable glitch width 5ns. Setup/hold time 10ns. 2 scope channels. bandwidth 100MHz. Simultaneous maximum sampling rate/Ch - 400 MSa/s. HpIb,RS232C. FDD.

Agilent 16500C Logic AnalyserHp,16500C AUMainframe with 16555D acquisition card and 16522A pattern generator module. 110MHz 68 channels. Memory depth 2M (4M in half channel timing mode). Minimum detectable glitch 3.5ns. Advanced trigger macros for capturing elusive problems.

lOgic/analySerS/teSterS

IceTech LV48 ProgrammerICE,LV48 AUEprom programmer for single device with laptop and preloaded software. programs devices up to 48 pins.Data IO Chipwriter StandardDAT,CHIpWRITER AUEprom programmer for single device with laptop and preloaded software. programs devices up to 40 pins.Data IO Chipwriter Gang 8 ChipDAT,CHIp-GANG AUEprom programmer for 8 devices. Eight copy sockets and one master socket. Can be used with a PC or in stand alone mode (two button operation). Programs devices up to 32 pin DIP.

Hi-Lo All 11 ProgrammerALL,11 AUprogrammer for byte wide EpROM, EEpROM and flash pROM with 24~32 pins. Enables programming or copying of up to 8 devices at a time. Adaptors provided to convert standard dip arrangement to pLCC for programming/copying of single (one only) pLCC packages. Unit will handle devices up to 8Mb. i.e. 27C010~27C080.Spectronics Ultra Violet PROM EraserSpE,ERASER2 AUHolds up to 8 devices. 0~60min timer, 240V/50Hz operation.

prOm prOgrammerS

HP35660A 100kHz Dual Channel Spectrum AnalyserHp,35660A AU/MYDisplays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. 401 line resolution. Signal sources: fixed sine, random noise, chirp. built-in disk drive. HpIb interface. bandwidth is 102.4kHz for single channel measurements and 51.2kHz for dual channel measurements.

>NEW HP35670A 100kHz Spectrum Analyser

Hp,35670A AUQuad channel 100 khz spectrum analyser. Up to 1600 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal sources: Fixed & Swept sine, Arbitrary Waveform, Random noise, Chirp. built-in disk drive. HpIb plotter interface. bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel measurements respectively.

frequency reSpOnSe analySerS

Page 21: 2007 Rentalsolutionsguide-Aunz Low

New U1250A series handheld DMMs place versatility at your fingertips!

• 50,000 count resolution, dual displays

• Unlimited data logging from DMM to PC

• Programmable square wave generator

• Temperature, Capacitance, Maths functions

• 20MHz frequency counter

Say hello to the next generation of Agilent Technologies;

the new handheld digital multimeters and oscilloscopes

that are built to test and designed to save.

Featuring built-in battery charging capability, exciting

and innovative new features and over-mould casing for

protection in the toughest conditions.

If you need a test instrument that offers the ultimate

portable test capabilities, Agilent’s range of handheld

digital multimeters and oscilloscopes are the right choice.

Performance on-the-move

Strength in the palm of your hand

New U1600A series handheld scopes bring high performance on the move!

• Scope-DMM-Recorder - all-in-one

• 4.5-inch LCD colour display

• FFT, Zoom and Math functions

• 200MSa/s sampling rate

• 125kB/ch memory depth

Redefining Feature-Rich Portability with the New Handheld Series

Australia 1300 726 550(Measurement Innovation - Australia wide)

New Zealand 0800 738 378

www.agilent.com/find/U1250Awww.agilent.com/find/U1600A

View an online demo:

www.agilent.com/find/U1250A_showcase

www.agilent.com/find/U1600A_showcase

Page 22: 2007 Rentalsolutionsguide-Aunz Low

12

GENERAL ELECTRONIC TEST EQUIPMENT

Racal 9906 Frequency Counter/TimerRAC,9906 AUCounter/timer 200MHz. Eight digit display. Measures frequency, period, totalise, time interval and ratio. Input impedance 1MΩ. Input sensitivity 10mV.

Sick WL260-P230 Reflex Photoelectric SwitchSIC,WL260-p230 AULight and sensor in the same unit. Detects reflection from reflector mounted on or behind the object to be detected. Range 0.01~5m. Output compatible with Racal 9906 counter. Mains operated. Supplied 50 x 50mm reflector. Does not work with normal mirror, white card etc, detects interruptions using supplied mirror.

Philips PM6666 1.1GHz Universal CounterpHI,pM6666 AUFrequency, period, time interval, totalise, and ratio measurements. GPIB interface. High stability MTCxO timebase option fitted.

HP 53181A 3GHz Frequency CounterHp,53181A AU/MYOption 010 high stability timebase included. HPIB interface. PC based benchlink meter software available.

HP 5350A 20GHz Frequency CounterHp,5350A MYAutomatic Microwave Counter. Input 1: 500MHz~20.0GHz 50Ω input impedance. Input 2 10Hz~525MHz at 50Ω. 10Hz~80MHz at 1 MΩ. HpIb interface standard. Option 006 input damage protection included.

HP 5352B 40GHz Frequency CounterHp,5352b AUAutomatic microwave counter. Input 1 500MHz~40GHz. Input 2 10Hz~525MHz. Sensitivity at 40GHz to 20dbm. TCxO timebase with aging rate 1 part in 10 million per month. HpIb interface. Input connector ApC-3.5 (male) with collar; type N adaptor included.

HP 5385A 1GHz Frequency CounterHp,5385A AUEleven digit display. Also measures period up to 0.1s. TCxO timebase. Operates from ac or 9~15Vdc. HpIb interface.

Model Type Frequency (GHz)RAC,9906 Universal frequency counter dc~0.200

SIC,WL260-pC230 Optical timing sensor

PHI,PM6666

Universal frequency counter

dc~1

Hp,5350A

Hp,53181A dc~3

HP,5352B Automatic microwave counter 10Hz~20GHz

Hp,5385A Universal frequency counter, DC operation dc~1GHz

ADV,TR5212 Universal frequency counter 10MHz~18GHz

frequency cOunterS

Page 23: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 13

RF &

MIC

ROW

AVE

HP E4432B ESG-D3000A 3GHz RF Digital Signal GeneratorHp,ESG-D3000A MYRF signal generator with digital modulation facilities. Frequency range 250kHz~3GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation. Wideband AM modulation. DC to 10MHz. Internal modulation and pulse generator to 50kHz. Step sweep of frequency and power. Included option UN3 provides DECT, GSM, NADC, pDC, pHS, & TETRA standards. External analogue I & Q modulation inputs. Option 1E5 high stability reference 0.1ppm/yr included.

HP E4433B ESG-D4000A 4GHz RF Digital Signal GeneratorHp,ESG-D4000A AUSignal generator with digital modulation facilities. Frequency range 250kHz~4GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation. Wideband AM modulation. DC to 10MHz. Internal modulation and pulse generator to 50kHz. Step sweep of frequency and power. Option 1E5 high stability reference 0.1ppm/yr included.HP 8648B 2GHz Signal Generator (Analogue)Hp,8648b AU/MYFrequency range 9kHz~2GMHz. Output range 13dbm~-136dbm, 1db accuracy over entire frequency range, resolution 0.001Hz. Full remote control via GpIb (IEEE488) interface.

HP 8648C-1E5 3GHz Signal GeneratorHp,8648C AU/MYSignal generator 9kHz~3.2GHz with AM/FM/phase modulation output range from +10~-136 dbm with ±1 accuracy up to 2.5GHz. 0.001Hz resolution. Complete with option 1E5 high stability timebase (<±0.1ppm/yr).HP/Agilent 8648D-1E5 4GHz Signal GeneratorHp,8648D AU/NZ/MYSignal generator 9kHz~4GHz with AM/FM/phase modulation output range from 10~-136dbm with ±1db accuracy up to 2.5GHz. 0.001Hz resolution. Complete with option 1E5 high stability timebase (<±0.1ppm/yr).

Fluke 6060B 1GHz Signal GeneratorFLU,6060b AUprogrammable high stability AM/FM signal generator. 0.01~1.05GHz, 10Hz resolution, 13~-127dbm output. Digital display of frequency, modulation and amplitude. Fifty complete front-panel settings can be stored in non-volatile memory for frequently repeated tests. Reverse power protection. Optional low rate ac FM and IEEE-488 interface fitted.

rf Signal generatOrS

Model Type (All programmable) Frequency OutputHp,ESG-3000A AM/FM microwave signal generator 250kHz~3GHz

Hp,ESG-D4000A AM/FM high stability microwave signal generator 250kHz~4GHz

Hp,8648b High stability signal generator 9kHz~2GHz 13dbm~-136dbm

Hp,8648CAM/FM high stability signal generator

9kHz~3.2GHz10dbm~-136dbm

Hp,8648D 9kHz~4GHz

FLU,6060b AM/FM high stability signal generator 10kHz~1,050MHz -127dbm~13dbm

HP 8350B Sweeper MainframeHp,8350b AU/MYOperates directly with Hp,8757A scalar network analyser and Hp,7475A plotter or Hp,2225A printer.HP 83525B 10MHz~8.4GHz Sweep ModuleHp,83525b AUSweep generator module for Hp,8350b. Frequency range 10MHz~8.4GHz.HP 83594A Module for 8350B 2 to 26.5GHzHp,83594A AUbroadband sweeper plug-in for Hp,8350b mainframe. Frequency range 2~26.5GHz. Max levelled output 10mW up to 20GHz, 2.5mW up to 26.5GHz.

HP 83592A Sweeper Plug-in 10Mhz~20GHzHp,83592A AUbroadband plug-in for Hp,8350b mainframe. Frequency range 10MHz~20GHz. Max levelled output power 10dbm. External AM and FM modulation.HP 83592C High Power 13dB Sweeper Plug-inHp,83592C AUbroadband plug-in for Hp,8350b mainframe. Frequency range 10MHz~20GHz. Max levelled output power 13dbm. External AM and FM modulation.

rf SWeep generatOrS

ENI 604L 4 W Wideband 1GHz RF AmplifierENI,604L AULinear wideband RF power amplifier. 4W output at an input of 0.13mW from 0.5~1GHz. Saturated output 7W 0dbm input. Extended performance gives saturated output to a max of 16W at 10MHz and 12W at 100MHz typically.

rf amplifierS

Page 24: 2007 Rentalsolutionsguide-Aunz Low

14

RF & MICROW

AVE

Spectrum analySerS - high frequency

Model Type Frequency Resolution (Hz)HP,8591E

Spectrum analyser9MHz~1.8GHz

1kHzHp,8594E9kHz~2.9GHz

Hp,8594E-G Spectrum analyser with tracking generator

ADV,R3365A Spectrum analyser with tracking generator 100kHz~8GHz 10

Hp,E4407b

Spectrum analyser

9kHz~26.5GHz 30

HP,8591 9kHz~1.8GHz 1kHz

HP,8593E 9kHz~22GHz 30

HP,8563E Spectrum analyser, high resolution 9kHz~26.5GHz 1

AIR,AIRMAG SpEC AN Spectrum analyser 2.5~2.5GHz4.9~5.9GHz

ANR,MS2711A Portable spectrum analyser9kHz~3GHz

10kHz

ANR,MS2711D Spectrum analyser, colour, portable100

ANR,MS2711D-6-29 Spectrum analyser with power meter 9kHz~6GHz

ANR,S332bNetwork analyser with spectrum analyser 9kHz~3GHz

10

ANR,S332D 100

ANR,S332D-29 Network analyser with spectrum analyser with colour screen 10

RS,FSH3-TG Spectrum analyser with tracking generator and return loss bridge 100kHz~3GHz

1kHzRS,FSH3-TG-V Spectrum analyser with tracking generator and vector measurements 100kHz~3GHz

RS,FSH6-TGPortable spectrum analyser

100kHz~6GHz

ADV,U3771 9kHz~31.8GHz 100

[email protected]

Gear up for your next adventure The R&S®FSH - for on-site RF measurements

Where is your next adventure in RF measurements taking you? To install a base station on the African savanna? To perform distance-to-fault measurements on the International Space Station? Then you need a flexible and robust do-it-all solution - the R&S®FSH Handheld Spectrum Analyser. It’s an entire test lab that fits in one hand: spectrum analyser, vector network analyser, high-precision power meter, test receiver, EMI/EMCE analyser and much more. It also features a wide selection of accessories.

Page 25: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 15

RF &

MIC

ROW

AVESpectrum analySerS - high frequency

Rohde & Schwarz FSH3 Spectrum Analyser/Tracking GeneratorRS,FSH3-TG AU/NZHandheld portable battery operated spectrum analyzer 100kHz~3GHz. Resolution bandwidth 1kHz~1MHz. Noise level to 3GHz -112dbm typical, 5-6GHz -102dbm typical. Colour liquid crystal display. Suitable for RF surveying applications. Includes tracking generator, VSWR bridge and distance to fault (DTF) options making it suitable for antenna and cable testing. Four hours of continuous operation on battery power. Cable for data transfer to PC.

Rohde & Schwarz FSH6 Spectrum Analyser/Tracking GeneratorRS,FSH6-TG AU/NZSpecification as above but capacity is 6GHz.

>NEW Airmagnet Spectrum Analyser

AIR,AIRMAG SpEC AN AULaptop base spectrum analyser. Specifically identify sources of interference in all Wi-Fi bands 2.4~2.5GHz and 4.9~5.9GHz, and track them to their physical source. Automatic and real time identification of bluetooth, cordless phones, microwaves, analog video cameras, RF jammers and more. Immediately “see” and name each device.

>NEW Rohde & Schwarz FSH3 Spectrum Analyser/ Tracking Generator /Vector Measurements

RS,FSH3-TG-V AUHandheld portable battery operated spectrum analyser 100kHz~3GHz. Resolution bandwidth 1kHz~1MHz. Less than -105dbm noise level(-114dbm typical). Colour liquid crystal display. Suitable for RF surveying applications. Includes Vector Transmission and Reflection Measurements option, tracking generator, VSWR bridge and distance to fault (DTF) options making it suitable for antenna and cable testing. 4h of continuous operation on battery power. Comes with cable for data transfer to PC.

HP 8591E 1.8GHz Spectrum AnalyserHp,8591E AURange 9kHz~1.8GHz. Resolution 1kHz~3MHz. Card reader allows data storage and also downloading of a range of measurement options (not included). Most assets include option 010 tracking generator and option 021 HpIb interface. One analyser includes; option 130 gives 30~300Hz resolution, option 041 HpIb interface and quasi peak detector and option 103 AM/FM demodulation.

>NEWAdvantest 31.8GHz Portable Spectrum Analyser

ADV,U3771 AUportable 9k to 31.8GHz spectrum analyser. 3 way power battery, 240V & DC. RbW 100Hz-3MHz, sensitivity -117 dbm@34 GHz (typ). Includes a wide variety of data analysis functions & zoom function. With signals applied to both Input 1 and Input 2, two signals such as an IF signal and a carrier can be measured. 5 min warm-up, Support for USb for printer and memory Storage Image formats: pNG, bMp, configuration file bIN, xML. Colour LCD. OpT.20-High-stability frequency reference crystal.

Advantest R3365A 8GHz Spectrum Analyser with Tracking GeneratorADV,R3365A AUFrequency range 100kHz~8GHz. Sensitivity -145dbm. Resolution 10Hz. Adjacent channel leakage power measurement and digital radio measurement functions. Gated sweep function for TDMA and video signal analysis. In-built tracking generator 100kHz~3.6GHz. GpIb & RS232 interfaces. Memory card reader.HP/Agilent E4407B 26.5GHz Spectrum AnalyserHp,E4407b AUFrequency range 9kHz~26.5GHz. Resolution bandwidth down to 30Hz. Noise level -105~-136dbm according to frequency. Centre frequency display with a resolution of up to 10Hz. Stores up to 200 traces in internal memory and 200 traces on disk. Some assets include GpIb/parallel interface with benchlink software (option A4H) and narrow resolution black/white (option 1DR).

Page 26: 2007 Rentalsolutionsguide-Aunz Low

Field tested. Field trusted.

Master every challenge the fi eld throws your wayField-proven, built to last, and easy to use, the Master family from Anritsu is the most trusted family of handheld measurement tools for RF and Microwave fi eld testing. So whatever you need to measure, and wherever you need to test, you can rely on one of the end-to-end, application-specifi c solutions in our Master family.

Call 1800 689 685 (Australia only) or visit our US web site www.us.anritsu.com

Page 27: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 17

RF &

MIC

ROW

AVESpectrum analySerS - high frequency

HP 8593E 22GHz Spectrum AnalyserHp,8593E AU/MYFrequency range 9kHz~22GHz. Max resolution 30Hz. Noise level -102~-127dBm according to frequency. Centre frequency display with a resolution of up to 10Hz. Some assets include GpIb/parallel and narrow resolution black/white options (041 & 130).HP 8582A 22GHz Spectrum AnalyserHp,8562A MYRF Spectrum Analyser, 9kHz to 22GHz. resolution 100Hz to 2MHz. HpIb plotter interface.HP 8563E Spectrum AnalyserHp,8563E AU/MYRange 9kHz~26.5GHz. Resolution 1Hz~2MHz. Sensitivity up to -139dbm. HPIB plotter and printer interface.

HP 8594E Spectrum AnalyserHp,8594E MYRange 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or less than 122dbm & 5MHz~2.9GHz equal to or less than 127dbm for 30Hz RBW.HP 8594E-G Spectrum Analyser with Tracking GeneratorHp,8594E-G MYRange 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or less than 122dbm & 5MHz~2.9GHz equal to or less than 127dbm for 30Hz RbW. With tracking generator option installed.Anritsu MS2711A Portable Spectrum AnalyserANR,MS2711A MYportable spectrum analyser, 9kHz~3GHz. Light weight battery powered spectrum analyser with LCD. Resolution bandwidth down to 10kHz. Suitable for cellular telephone walk or drive tests to determine coverage and base station positioning. Can also be used for VHF/UHF signal surveying. N type connector.

Anritsu MS2711D 6GHz Spectrum Analyser with Power MeterANR,MS2711D-6-29 AUportable spectrum analyser, 9kHz~6GHz with power meter. Light weight battery powered spectrum analyser with LCD. Resolution bandwidth from 100Hz~1MHz. Has feature which can identify the type of interfering signal. Can be used in applications such as cellular telephone walk or drive tests to determine coverage and base station positioning and also VHF/UHF signal surveying. Has N type connector.Anritsu MS2711D Colour Portable Spectrum AnalyserANR,MS2711D AUColour portable spectrum analyser, 9kHz~3GHz. Light weight battery powered spectrum analyser with colour LCD. Resolution bandwidth from 100Hz~1MHz. Has feature which can identify the type of interfering signal. Can be used in applications such as cellular telephone walk or drive tests to determine coverage and base station positioning and also VHF/UHF signal surveying. N type connector.

>NEW Anritsu Frequency Converter Module FCN4760

ANR,FCN4760 AU/MYblock down converter for the 4.7GHz~6.0GHz frequency range designed to work with an ANR,MS2711D (with Option 6). Adds frequency range 4.7GHz ~6.0GHz to the ANR,MS2711D.

Page 28: 2007 Rentalsolutionsguide-Aunz Low

18

RF & MICROW

AVE

Anritsu S331D Colour Sitemaster AntennaANR,S331D AU/MYAntenna and cable test set. battery operated with colour display. Frequency range 25~4000MHz. Measures return loss, SWR, cable loss, and distance to fault. Integral synthesized signal generator. Return loss range 0~60db. SWR range 1~65. Distance to fault range 1,197m. Insertion loss range -120.00~+100db. Cable loss range (one port) 0~30db. Type n(f) port. RS232 interface for printer or pC. Analysis software discs included containing distance to fault and Smith chart tools. Complete with Instacal calibration standard, AC/DC adaptor and 12Vdc car cigarette lighter adaptor.Anritsu S332B Sitemaster including 3GHz Spectrum AnalyserANR,S332b AUAntenna and cable test set with spectrum analyser. Frequency range 25~3300MHz for cable and antenna test. 9kHz~3GHz for spectrum analysis. Measures return loss, SWR, cable loss, and distance to fault. Integral synthesized signal generator. Return loss range 0.00 to 54.00 db. SWR range 1.00 to 65.00. Distance to fault rang e 1000 m. Insertion loss range -120.00 to +100 db. Cable loss range (one port) 0.00 to 20.00 db. Type n(f) port. RS232 interface for printer or PC. Spectrum analyser resolution bandwidth down to 10 KHz. Analysis software discs included containing distance to fault and Smith chart tools. Complete with standard load and short, AC/DC adaptor and 12 V DC car cigarette lighter adaptor.Anritsu S332D Colour Sitemaster incl 3GHz Spectrum AnalyserANR,S332D AU/NZAntenna and cable test set with spectrum analyser. battery operated with colour display. Standard signal table allows automated setup. Frequency range 25~4GHz for cable and antenna test. 9kHz~3GHz for spectrum analysis. Measures return loss, SWR, cable loss, and distance to fault. Integral synthesized signal generator. Return loss range 0~60db. SWR range 1~65. Distance to fault range 1,197m. Cable loss range 0~30db. Spectrum analyser resolution bandwidth 100Hz~1MHz. Interfering signal feature allows identification of type of interference. Type N(f) port. RS232 interface for printer or pC. Analysis software discs included containing distance to fault and Smith chart tools. Complete with calibration components, ac/dcadaptor and 12Vdc car cigarette lighter adaptor.

Anritsu S820A Microwave Sitemaster 3~20GHz ANR,S820A AUMicrowave antenna and cable test set. portable (1.14kg) single post analyser, providing return loss (SWR) insertion loss and distance to fault measurements in the frequency range of 3.3GHz~20GHz. RS232 interface. Smith chart and software management tools, ac/dc and automotive adaptor. A comprehensive range of precision waveguide components and adaptors are available.Anritsu S820D Microwave Sitemaster 25MHz~20GHzANR,S820D AUMicrowave antenna and cable test set. Portable single post analyser, providing return loss (SWR) insertion loss and distance to fault measurements in the frequency range of 25MHz~20GHz. Unit comes standard with RS232 interface, Smith chart and software management tools, AC/DC and automotive adaptor. A comprehensive range of precision waveguide components and adaptors are available.Anritsu Sitemaster Waveguide ComponentsANR,WAVEGUIDE-ADAp AUCalibration components and wave guide to co-ax adaptors for Anritsu S820A Sitemaster antenna. Set includes 1/8 and 3/8 shorts, termination, and waveguide to co-ax adaptor.HP 8753D 6GHz Vector Network AnalyserHp,8753D AUVector network analyser with integral S-parameter test set. Frequency range 30kHz~6GHz with included option 006. In-built 1Hz resolution synthesized signal source. Calibration kit included. HP 8753ES 3GHz Vector Network AnalyserHp,8753ES AU/MY3GHz Vector Network Analyser allows complete characterization of RF components. Includes an integrated synthesized source, test set and tuned receiver. The built-in S-parameter test set provides a full range of magnitude and phase measurements in both the forward and reverse directions.

netWOrk analySerS/antenna & cable teSt

Model Type Frequency Return Loss SWR RS232 dc Supply

ANR,S331b Antenna & cable test set 25MHz~3.3GHz

ANR,S331CAntenna & cable test set 25MHz~4GHz

Yes Yes Yes Yes

ANR,S331D

ANR,S332b Antenna & cable test set plus spectrum analyser 25MHz~3.3GHz

ANR,S332D Antenna & cable test set plus spectrum analyser 25MHz~4GHz

ANR,S820A Antenna & cable test set 3GHz~20GHz

ANR,S820A Microwave antenna and cable test set 25Mhz~20GHz

ANR,C752-05 Antenna & cable test set (75ohm) plus power meter 5MHz~1.2GHz

Hp,8752A Vector network analyser transmission reflection test set 300kHz~3GHz

HP,8753DVector network analyser S parameter test set

30kHz~6GHz

HP,8753ES 30kHz~3GHz Yes Yes

HP,8757CScalar network analyser

60GHz

HP,8757D 10Mhz Yes Yes

Page 29: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 19

RF &

MIC

ROW

AVE

HP 8757A Scalar Network AnalyserHp,8757A AUScalar network analyser (Scalar denotes gain measurement only - no phase). 76db dynamic range. Frequency range to 60GHz depending on detector used. 3 x Hp11664A’s included. Analyser will act as system controller with HP8350B sweeper. Output to HPIB plotter or HP2225 printer.HP 8757C Scalar Network AnalyserHp,8757C AUScalar network analyser 10 MHz~40 GHz. 76db (+16 to -60dbm) dynamic range. Three detector inputs. Two display channels. Color display. Complete with 3 x Hp,11664A detectors.HP 8757D Scalar Network AnalyserHP,8757DMeasures insertion loss, gain, return loss, SWR, and power from 10MHz~110GHz.

HP 11679A Detector Extension CableHp,11679A MYExtension cable for use with Hp,11664A detectors and Hp,8757 network analysers. Length 7m. Extends the power and detected signal cable length.

HP 85032B Calibration KitHp,85032b AUCalibration kit for network analysers. Simplified version without adaptors.

>NEW Emerson Process Management 375 Field Communicator

EME,375 MY Will configure, test, and diagnose your HART® and Foundation Fieldbus devices. Able to communicate with any device, by any manufacturer. Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS pC Suite Software.

netWOrk analySerS/antenna & cable teSt

Model Type FrequencyANR,WIFI-ANTENNA WIFI antenna 2.4GHZ~5.8GHz

ANR,ANTENNA Dipole antenna 25MHz~1.7 GHz

ADV,TR1720 Loop vertical antenna system 100kHz~30 MHz

AH,SAS-200/574Double ridge guide horn antenna

18GHz~40 GHz

AH,SAS-200/571 700MHz~18 GHz

RS,HL013 Log periodic antenna 80MHz~1300 MHz

AN,SAS-200/550 Monopole rod antenna 100kHz~60 MHz

HOL,HI-3002 Isotropic RF radiation monitor 500kHz~6 GHz

NAR,8616 Radio frequency radiator monitor 300MHz~26 GHz

SE,MONITOR 4 Alpha, beta, Gamma and x-Ray radiation monitor

SE,MCIK Gamma x-Ray radiation monitor

HOL,HI-3004 Isotropic RF low level field strength meter 0.5MHz~6 GHz

WG,ESM-20 personal RF field monitor 1MHz~18 GHz

NAR,8217 Field strength meter for microwave ovens 2.4GHz

ROb,Tx90 Microwave oven leakage detector 2.4GHz

PRO,3201 RF signal analyser & meter 100kHz~2.06GHz

AH,ANTENNA Log periodic antenna 300MHz~12GHz

field Strength meterS & antennaS

See also TV Test Equipment

Advantest TR1720 100kHz ~30MHz AntennaADV,TR1720 AULoop and vertical antenna system. Frequency range 100kHz~30MHz. Suitable for use with ADV,R4131D for field strength and EMI measurements. Antenna tuner included which can be used as an input/output filter to reject noise below the measuring frequency.AH Systems SAS-200/571 AntennaAH,SAS-200/571 AUAH,SAS-571 MYDouble ridge guide horn antenna. Frequency range 700MHz~18GHz. Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type N(f) connector.

AH Systems SAS-200/574 18~40GHz AntennaAH,SAS-200/574 AUDouble ridge guide horn antenna 18~40GHz. Gain in excess of 15db. Type K(f) connector compatible with 3.5mm connectors including SMA. Complete with tripod.AH SAS-200/550-2B 100Hz~60Mhz Rod AntennaAH,SAS-200/550 AUMonopole rod antenna. Frequency range 100Hz~60MHz. Active unit with battery power. Rod height 220mm~1.09m. Ground plane 450 x 450mm. Antenna factor 0~24.

Page 30: 2007 Rentalsolutionsguide-Aunz Low

20

RF & MICROW

AVE

field Strength meterS & antennaSAH Systems 300MHz ~12GHz Antenna SystemAH,ANTENNA AULog periodic antenna system. Comprises two antennas: A: 300MHz~1.8GHz, power handling 1kW, antenna factor 15~32db, b: 1~12GHz, power handling 10W, antenna factor 25~44db. Complete with tripod.Anritsu Dipole Antenna KitANR,ANTENNA AUComprises types Mp534A and Mp651A antenna covering 25~520 & 470~1,700MHz. Complete with tripod type Mb9A and coaxial cable.Anritsu 2.4/5.8GHz WIFI 802.11A/B/G AntennaANR,WIFI-ANTENNAHigh precision antenna set for wireless network test applications (802.11A/b/G, 11Mbps &54 Mbps). Includes 2.4GHz and 5.8GHz antennas with reverse SMA connectors. Also includes precision reverse SMA to N type adapter to fit standard test equipment.Rohde & Schwarz HL013 80MHz~1.3GHz Log-Periodic AntennaRS,HL013 AUComplete with tripod.Holaday HI-3002 Field Strength MeterHOL,HI-3002 AUIsotropic RF radiation monitor. E-field & H-field probes spanning 500kHz~6GHz (E-field) & 5~300MHz (H-field). Operates from batteries.

Narda 8616 Radiation Hazard MonitorNAR,8616 AURadio frequency radiation monitor complete with probes. Battery operated with analogue meter and recorder output (3Vdc full scale). Probe type 8623b has a calibrated frequency range of 300MHz~26GHz over a range of 0.05~100mW/cm2. (Frequency range up to 8GHz is calibrated to NATA standard, above 8GHz calibration is to manufacturer’s specifications). probe type 8633 has a frequency range of 10~300MHz over a range of 0.05~100mW/cm2.SE International Monitor 4 Nuclear/X-Ray MonitorSE,MONITOR 4 AU/MYAlpha, beta, Gamma & x-ray radiation monitor. Meter, LED & audible indication. Range; 0~0.5, 5, 50mR/hr, 0~500, 5,000, 50,000CpM, 0~5, 50, 500µSv. Energy sensitivity Alpha 2.5MeV, beta 50KeV, Gamma & x-ray 10KeV. Battery operated.SE International Monitor MC1K Radiation Survey MeterSE,MCIK AUGamma & x-ray radiation monitor. Meter, LED, and audible indication. Ranges 0.1~1,000mR/h & 0.01~10mSv/h full scale. battery operated.

Holaday HI-3004 Field Strength MeterHOL,HI-3004 AUIsotropic broadband field strength meter designed primarily to measure low level fields for EMI/EMC studies. Meter scale calibrated in v/m, with pointer deflection proportional to v2/m2. Supplied with HSE high sensitivity E-field probe & STE E-Field probe. HSE probe has 4 ranges, 1v/m ~30v/mFS, 0.5~1,500Mhz. STE probe has 4 ranges 100v/m~3,000v/mFS, 0.5Mhz~6Ghz. Recorder output (0~1Vdc).WG ESM-20 Radiation MeterWG,ESM-20 AUpersonal monitor and leakage detector for high frequency electromagnetic fields. Simultaneous E and H field measurements with audible and visual alarms. Frequency range H field 1 MHz to 1 GHz; E field 1 MHz to 40 GHz. Operation as personal monitor with compensation for human body absorption, or with isotropic detection for RF leakage sensing and simple four-level measurement using LED indicators. battery powered - battery life over 200 hours.Narda 8217 Microwave Oven Survey MeterNAR,8217 AUMicrowave oven survey meter complete with beaker and thermometer for oven power measurement. Calibration frequency 2.45GHz. Measurement range 0.5~10mW/cm2. Battery operated.Robin Electronics TX90 Microwave Leakage DetectorROb,Tx90 AUMicrowave leakage detector. Eight dipole analogue meter reading. Ranges 1~10mW/sqcm & 0·1~1mW/sqcm. Display analogue moving coil. power density accuracy ±1dB. Probe area 2cm2. Supplied with a manufacturers certificate of calibration traceable to National Standards. Powered by 9V alkaline battery.Protek 3201 RF Analyser/Signal MeterpRO,3201 AURF signal analyser and level meter. Provides spectrum display up to 2.06GHz, audio output, level measurement, and frequency measurement. Inbuilt antenna. Frequency range 100kHz~2.06GHz with frequency steps from 5kHz. Modulation types narrow and wide band FM, AM, and SSb. Level measurement min frequency - narrow band FM 1MHz, wide band FM, AM, SSb 10MHz. bandwidth - narrow band FM 12.5kHz, wide band FM 180kHz, AM & SSb 2.4kHz. Frequency measurement 9MHz~2.06GHz. Input impedance 50Ω.

Protek 3290 RF Analyser/Signal Meter 2.9GHzpRO,3290 AURRF signal analyser and level meter. Provides spectrum display up to 2.9GHz, audio output, level measurement, and frequency measurement. Inbuilt antenna. Frequency range 100kHz~2.9GHz with frequency steps from 5kHz. Modulation types narrow and wide band FM, AM, and SSb. Level measurement minimum frequency - narrow band FM 1MHz, wide band FM, AM, SSb 10MHz. bandwidth - narrow band FM 12.5kHz, wide band FM 180 kHz, AM & SSb 2.4 kHz. Input impedance 50Ω.

Marconi TF2304 Auto AM/FM Modulation MeterMAR,TF2304 AUAutomatic operation. Frequency 9~12.5MHz & 18~1,000MHz, FM deviation 8 ranges, 1.5~150kHz FS AM depth 3 ranges, 10~30~100%.

mOdulatiOn meterS

Page 31: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 21

RF &

MIC

ROW

AVE

Laplace RF Absorbing ClampLAp,RF-CLAMp AUFor measurement of emissions from power and other lines to CISPR and VDE standards. Frequency range 30 MHz~1GHz. Output 50Ω.Laplace SA1000 EMC Test SystemLAp,SA1000 AUComprises pC controlled spectrum analyser 10kHz~1.1GHz, SA1020 pre-amplifier, RF200 broadband antenna 30MHz~1Hz, TTI LISN1600 LISN, and RF100 E-field & H-field probes. Supplied with notebook pC and EMC software.

>NEW Schaffner Modula-6100 Immunity Test System

SFN,MODULA 6100 AUMultifunction generator to simulate electro-magnetic field interference effects for immunity testing in conformity with international, national and in house standards including the new IEC/EN standards. Generates Interference pulses such as burst and surge and power quality simulations.

Schaffner 438 30kV Static Discharge GeneratorSFN,438 AUGenerates an electrostatic charge in a range from 2~30kV. This instrument is in a ‘gun’ form. Removable discharge network which can be interchanged with other (optional) impedance networks. performs test to IEC1000-4-2 standards.

>NEW Schaffner Automated Step Transformer

SFN,INA-6502 AUIntegrated function unit to Modula system. power line dips to 0%, 40%, 70% and 80%. Complies with EN/IEC 61000-4-11. Includes EUT power control switch.Schaffner BestPlus B-1SFN,bEST+ AUEMC, ESD, PQT, Burst and Surge Immunity generator simulators. Includes ESD generator/gun.Schaffner NSG-420 RF Current Immunity TesterSFN,NSG-420 AUprovides pre-compliance testing to IEC 801-3 and IEC 801-6. Clamp coupled to power, data, and signal cables of a device under test. Injects noise signal from 100kHz~100MHz with a level response from 1MHz~10MHz. AM & FM modulation of source from a 1kHz oscillator source or an external input. Indication of signal current from source or existing signal. Also dc recorder output of this signal. Cable size up to 10 x 22mm. Operates for 1h on 4AA alkaline batteries.

emc teSt equipment

cOmmunicatiOnS teSt SetSMarconi 2945 Communications Test SetMAR,2945 AUOutput frequency range 400kHz~1.05GHz. Input frequency range to modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking generator with offset tracking inbuilt. power measurement to 150W. Full duplex operation. AMpS cellular option included. Spectrum analyser with 1kHz resolution. AC mains, external 11~32V and internal battery operation. RS232C remote control interface.

Marconi 2945A Communications Test SetMAR,2945A AUOutput frequency range 400kHz~1.05GHZ. Input frequency range to modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking generator with offset tracking in-built. power measurement to 150W. Full duplex operation. Spectrum analyser with 1kHz resolution. AC mains, external 11~32V dc on some assets, and external battery operation. RS232C remote control interface.HP 8920A Communications Test SetHp,8920A AURF Communications Analyser test set. Frequency range of 250KHz~1GHz. Includes an AM/FM signal generator, AM/FM modulation analyser, duplex offset generator, SSb demodulator, RF power meter, frequency counter, ac/dc voltmeter, SINAD meter, Distortion meter, oscilloscope and two variable audio sources. Includes Spectrum analyser with tracking generator. Antenna & microphone are included.

Page 32: 2007 Rentalsolutionsguide-Aunz Low

22

RF & MICROW

AVE

Model Type Frequency Power

Hp,E4418A Digital Power Meter *100kHz~50GHz*75GHz~110GHz

*100µW~25mW*-70dbm~44dbm

Hp,E4418b-001 Power meter, high speed, single channel *9kHz~110GHz *100µW~25mW*-70dbm~44dbm

Hp,E4419b-001 Power meter, high speed, dual channel *9kHz~110GHz *100µW~25mW*-70dbm~44dbm

Hp,8508A Vector voltmeter 100kHz~2GHz 90dB range

bIR,43 RF Thru-line power meter ∆450kHz~2.3GHzAccording to element ∆100mW~10kW

bIR,4391 In-line digital RF power meter

bIR,4421 In-line RF power meter 1.8MHz~32MHz25MHz~1GHz 300mW~1kW

bIR,ApM16 Average reading power meter for pCD GSM & CDMA 0.4~1GHz1.7~2.2GHz 2.5W~25W

BIR,ELEMENT Elements for Model 4391 ∆According to element

MAR,6970 Digital power meter ∆According to sensor

COL,DC1500A In-line RF power meter dc~0.5 GHz 100W

WAV,FIT RF power & VSWR meter 70MHz~1GHz 20mW~50W

R&S,NRT-Z43-Z44 Directional power meter200MHz~4GHz

30W

R&S,NRT power reflection meter 30W* Sensor Dependant# Element Dependant

pOWer meterS & SenSOrS - rf

>NEW HP 8508A Vector Voltmeter

Hp,8508A AUNarrowband measuring technique gives a range of over 90dB and a sensitivity of 10µV to trace the smallest signal. Measures the phase difference between its two input channels with at least 0.1º resolution over a full 180°~-180° range, so they can be used for another complete set of measurements such as electrical length, phase distortion, or impedance. 100kHz~1GHz with high impedance inputs. 300kHz~2GHz with 50Ω inputs. Circuit probing to facilitate the design process. Easy programming for ATS’s. Narrowband measurement capability for high sensitivity applications.

Agilent E4418B Series Power MeterHp,E4418b-001 AUDigital power meter. battery or mains powered. 100µW - 25W (-70dbm ~+44dbm), 9kHz~18GHz (depending on power sensor), 4 digit display - watts, dbm, db (rel). power sensor required, select and specify when ordering.

Model Type Frequency Power

Hp,8481A

Power Sensor

10MHz~18GHz1µW~100mW

Hp,8484A 0.1nW~10µW

Hp,E9300A

10Mhz~18GHz

0.1nW~100mW

HP,E9300B 0.1nW~25mW

HP,E9300H 10nW~1W

Hp,8485D 50MHz~26.5GHz 100pW~10µW

RS,FSH-Z1 1.8MHz~26.5GHz 300mW~1kW

Page 33: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 23

RF &

MIC

ROW

AVEpOWer meterS & SenSOrS - rf

HP E4419B Series Dual Channel Power MeterHp,E4419b-001 AUbattery or mains powered dual channel digital power meter. 100µW~25W (-70dbm~+44dbm), 9kHz~18GHz (depending on power sensor), 4 digit display - watts, dbm, db (rel). power sensor required, select and specify when ordering.

Hioki 3134 Digital Power MeterHIO,3134 MYAC line power meter, 3 phase W/V/A 1000kw uses two-wattmeter method for 3 wire systems. Can do 4 wire systems. Digital display plus analogue O/p for all display values V/A/W/VAR. Watts/VAR can both be O/p together to derive power factor. Supplied with 2x CT’s 3x volts I/p leads in case.Hioki 3136 Clamp-on Power MeterHIO,3136 MYpower meter 3ph, 4 wire. FSD 200/1000kW 1kA 600/3V 200/1000 kVAR recorder O/p 2V/50Ω 40~500Hz complete with 3 x CT’s 9002 unit will measure 1ph V, A & W. VA & VAR will need to be calculated. On 3ph it will measure VAR, VA will need to be calculated.Fluke 36 True RMS ac/dc Clamp MeterFLU,36 MYJaws accept 1 x 750 MCM (1.2 (3mm)) cable or 2 x 500 MCM, (0.98 (24.6mm)) cables up to 38mmØ. True-rms responding. Display 3.5 digit, 2000 count. Rugged design. AC current(45~400Hz), range 600A/200A, resolution 1A/.1A, accuracy 10~600A ±(2%+3) or 0.5~200A ±(2%+5), crest factor 2</-CF</-3, add 2% Rdg, overload protection, 600A continuous (CF</-3). DC current range 1kA/1kA/200A, resolution 1A/1A/1A, accuracy 0~600A ±(1.9%+4), 600~1000A ±(3%+3), 0~200A ±(1.9%+7), overload protection 1kA. AC volts(45~400Hz), range 600V/200V, resolution 1V/1V, accuracy ±(1.5%+3), crest factor <3 (pk voltage ±933V), overload protection 1200V rms. DC volts range 600V/200V, resolution 1V/1V, accuracy ±(1.0%+3), overload protection 1200V rms continuous. Manual ranging. Protective case & TL75 hardpoint test leads. Continuity beeper under 50Ω.Bird 43 Power MeterbIR,43 MYRF thruline power meter. Requires bird element of specified frequency and power. Measures forward and reflected power by reversing the element.Bird RF Element for Model 43 Power MeterbIR,ELEMENT AUbIR,ELEMENT-LF MYbIR,ELEMENT-HF MYbird watt meters. Available in various power and frequency ranges.Bird 4391 In-line Digital RF Power MeterbIR,4391 AURF power meter/analyser with pulse power capability covering 0.45~2,300MHz at a power of 100mW~10kW according to the elements selected (elements rented separately). Measures peak pulse, peak envelope, & CW power. pulse parameters: minimum width 0.8µs, 100~2,300MHz, 1.5µs, 26~99MHz, 15µs, 2~25MHz; minimum repetition rate 25pp/s & minimum duty factor 1 part in 10,000. Measures VSWR and percentage modulation. Operates from ac mains and rechargeable batteries.

Bird 4391A RF Digital Thru-Line Power MeterbIR,4391A MYDigital display, microprocessor-based operation and simplified, push-button control. Wattmeter is suited to telemetry, two-way communications, avionics, radar, and standard radio and TV applications. Freq. 0.45~2700MHz. power 100mW~10kW with 20% over-range. Reads forward and reflected CW or FM power in watts or DbM. Calculate SWR, return loss in db and % modulation.

Bird 4421 Wide Range Power MeterbIR,4421 AUComplete with 4021 sensor 300mW~1kW, 1.8~32MHz & 4022 sensor 300mW~1kW, 25MHz~1GHz. Max input 1.2kW. VSWR range 1~2. Measures forward & reverse power in W or dBm, VSWR, and return loss in dB. Digital display. Operates from ac mains or internal rechargeable batteries.

Bird APM16 Power MeterbIR,ApM16 AUAverage reading power meter intended for pCS, cellular (including CDMA, GSM) and general purpose applications. Includes in-line elements for 2.5 & 25W, frequency ranges 0.4~1GHz, 1.7~2.2GHz. battery operated.

Marconi 6970 Digital Power MeterMAR,6970 MYNi-Cad battery operated with digital display. Complete with AC adaptor. Requires sensor. Sensors available for 10MHz~26.5GHz frequency range.

Marconi 6970 Digital Power MeterMAR,6970 AU/MYNiCd battery operated with digital display. Complete with ac adaptor. Requires sensor. Sensors available for 10MHz~26.5GHz frequency range.Coline DC1500A VSWR/Power MeterCOL,DC1500A AUFrequency range: dc~1.5GHz. Accuracy ±5% of reading. Max continuous power 100W, intermittent 200W. Resolution 0.1W. VSWR measurement 30MHz~1.5GHz. Usable to 10MHz. power range for VSWR varies with frequency. Min 5W @ 30MHz, 30mW at 1.5GHz. Max 200W @ 30MHz, 50W @ 1.5GHz. Range 1.00~19.99. 50W RF load included.

Wavetek FIT RF Power and VSWR MeterWAV,FIT NZPortable RF power meter with VSWR, volts and resistance measurements. Frequency range is 70MHz~1GHz. power range is 20mW~50W, resolution is 10mW. Accuracy is ±0.5db at 1W. VSWR range is 1.2~10. Voltage measurement is 0~30V, resolution is 30mV. Resistance measurement is 0.2~1kΩ, resolution is 0.1.Rohde & Schwarz NRT-Z43-Z44 Directional Power MeterR&S,NRT-Z43-Z44 MYMeasures power and reflection under operational conditions. Wide frequency range from 200(400)MHz~4GHz covers all relevant frequency bands. Measurement method is compatible with all common analog and in particular digital modulation standards: GSM/EDGE, 3Gpp (W-/TD-CDMA), CDMA (IS-95), CDMA2000, pHS, NADC, pDC, TETRA, DECT, DAb, DVb-T and many more.Rohde &Schwarz NRT Power Reflection MeterRS,NRT MYMeasures power and reflection under operational conditions. Wide frequency range from 200(400) MHz ~4GHz covers all relevant frequency bands. Measurement method is compatible with all common analog and in particular digital modulation standards. GSM/EDGE, 3Gpp (W-/TD-CDMA), CDMA (IS-95), CDMA2000, pHS, NADC, pDC, TETRA, DECT, DAb, DVb-T and many more.

Page 34: 2007 Rentalsolutionsguide-Aunz Low

24

RF & MICROW

AVE

pOWer meterS & SenSOrS - rf

>NEWHP E9300A Power Sensor for HPE4416/18 Power Meters

Hp,E9300A AU/MYFor HpE4416/HpE4418 power meters. 10MHz~18GHz frequency range. 1nW~100mW (-60~+20dbm) power range. 320mW max average power handling (+25dbm), 2W (+33dbm) peak power (<10usec). N-Type connectors.

>NEW Agilent Power Sensor 1µW~25W, 10MHZ~8GHz

Hp,E9300b AUpower sensor for Hp EpM series power meters. E-series average power sensor. 10MHz~18 GHz, 1µW~25W (-30dbm~+44dbm).

>NEW HP 8485D Power Sensor 100pW~10uW, 50MHz~26.5GHz

Hp,8485D AUpower Sensor 100pW to 10uW, 50MHz to 26.5GHz.

>NEW Rohde & Schwarz Power Sensor for RS,FSH 10MHz~8GHz

RS,FSH-Z1 AUpower sensor for RS,FSH 10MHz~8GHz. 200pW~200mW(-67dbm~23dBm).

HP E9300H Power Sensor 10nW~1W, 10MHz~18GHzHp,E9300H AUpower sensor for Hp EpM series power meters. E-series Average power Sensor. 10 MHz~18 GHz, 10nW~1W (-50dbm~+30dBm).

HP 8481A 10MHz~18GHz Power Sensor for HP43X Series MetersHp,8481A AUFor Hp436A, HpE4418b & HpE4419b. 10MHz~18GHz, 1µW~100mW.

HP 8484A 10MHz~18GHz Power SensorHp,8484A AUpower sensor 10MHz~18GHz, 0.1nW~10µW. Complete with Hp,11708A 30dB reference attenuator.

Marconi 6910 Power SensorMAR,6910 MYFrequency range 10MHz~20GHz. power range -30dbm~20dbm (1μW~100mW). Max RF i/p 25dbm (300mW) CW 42dbm (15W) peak for 2μs. Sensing element semiconductor thermocouple. VSWR 1.25 10MHz~30 MHz, 1.1 30MHz~2GHz, 1.18 2~16GHz, 1.28 16~18 GHz, 1.4 typical 18~20GHz. Linearity factor provided with sensor. Accuracy ±0.5% at 25C between 10 & 20dBm. Improves by a factor of 10 for each lower rang. Calibration factor provided with sensor. Accuracy uncertainty provided with sensor. Resolution 0.01%. RF connector precision N-type (M) 50Ω.

Marconi 6912 Power SensorMAR,6912 MYFrequency range 30kHz~4.2GHz. I/p power range 30dbm (1μW) to 20dbm (100mW).

Marconi 6913 Power SensorMAR,6913 MYFrequency range 10MHz~26.5GHz. I/p power range 30dbm (1μW) to 20dbm (100mW). Max 25dbm (300mW) CW, 42dbm (15W) peak for 2μs. Sensing element semiconductor thermocouple. VSWR 1.40 10MHz~50MHz, 1.15 50MHz~100MHz, 1.10 100MHz~2GHz, 1.15 2~12.4GHz, 1.20 12.4~18GHz, 1.25 18~26.5GHz. Calibration factor provided at 1GHz intervals (500MHz intervals above 20GHz) with each sensor. Accuracy uncertainty provided with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5% at 100mW, decreasing by 0.005% per 1mW.

Marconi 6920 Power SensorMAR,6920 MYHigh sensitivity diode sensor. Frequency range 10MHz~20GHz. I/p power range 70dbm (0.1nW) to -20dbm (10μW), max 26dbm (400mW) CW +30dbm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR 1.4~1.2 10~40MHz, 1.20 40MHz~10GHz, 1.35 10~18GHz, 1.40 typical 18~20GHz. Calibration factor provided at 1GHz intervals with each sensor. Accuracy uncertainty provided with each sensor.

Marconi 6923 RF Power SensorMAR,6923 MYHigh sensitivity diode sensor. Frequency range 10MHz~26.5GHz. I/p power range -65dbm (0.3nW) to -20dbm(10μW), max 26dbm (400mW) CW, +30dbm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR 1.4 10~40MHz, 1.15 40~100MHz, 1.12 0.1MHz, 1.17 2~8GHz, 1.30 8~18GHz, 1.50 typical 18~26.5GHz. Calibration factor provided at 1GHz intervals with each sensor. Accuracy uncertainty provided with each sensor. Resolution 0.01%. Linearity factor provided with each sensor. Accuracy ±1% between -30 & -20dbm. RF connector type N (M) precision 50Ω.

Page 35: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 25

RF &

MIC

ROW

AVErf attenuatOrS

Model Type Attenuation (dB) Frequency (GHz) Power Max (W)

Hp,8494b-8496b

Coaxial step attenuator

121

dc~181

Hp,8494b 11

Hp,8495b 70

Hp,8494/5b 81

Hp,8495D Step attenuator 70 dc~26.5

WEI,33-10-34

Fixed

10 dc~8 25

WEI,34-30-34 30 dc~4 24

WEI,46-03-34 3

dc~18

50

WEI,46-06-34 6

25WEI,46-10-34 10

WEI,46-20-43 20

WEI,82-30-34 Coaxial attenuator 30 dc~3 1000

WEI,AS6 Calibrated attenuator 3

WEI,AS20 Variable attenuator 30 dc~26.5 2

WEI,M2020 Attenuator 20 dc~18

bIR,25A-10 Fixed 10 dc~4 25

NAR,705-69 Attenuator 30 dc~18 25

Weinschell 33-10-34 25 W 10dB 8.5GHz RF AttenuatorWEI,33-10-34 AU10db, 25W, dc~8GHz. Type N connectors.Weinschell 34-30-34 25W 30dB 4GHz RF AttenuatorWEI,34-30-34 AU30db, 25W, dc~4GHz. Type N connectors.Weinschell 46-03-34 50W 3dB 18GHz RF AttenuatorWEI,46-03-34 MY

Weinschell 46-06-34 50W 6dB 18GHz RF AttenuatorWEI,46-06-34 MYDC - 18GHz, 6 db, average power 25W, 200W peak. Type N connector.Weinschell 46-10-34 50W 10dB 18GHz RF AttenuatorWEI,46-10-34 MYDC - 18GHz, 10 db, average power 25W, 200W peak. Type N connector.Weinschell 46-20-43 25W 20dB 18GHz RF AttenuatorWEI,46-20-43 AU/MYDC~18GHz, 20db, 25W. Type N connectors.

>NEW Weinschel 82-30-34, 30dB 1000W 3GHz Coaxial Attenuator

WEI,82-30-34 AU30db 1000W 3GHz Coaxial Attenuator. DC to 3GHz.

Weinschell AS6 Calibrated Attenuator SetWEI,AS6 MYFrequency range DC-18GHz, set consists of 4 different nominal value 3, 6, 10 & 20db. Connector type N per mil-STD-348, power rating 5W.Weinschell AS20 Precision Attenuator SetWEI,AS20 AUDC~26.5GHz. Attenuator values 6,10,30 db. Average power 2W. 3.5mm connectors.Weinschell M2-20 AttenuatorWEI,M2-20 MY20 db attenuator. DC to 18GHz, double male N typeHP 8494B/8496B Attenuator Set 121dB x 1dBHp,8494b-8496b AUCoaxial step attenuator set. DC-18GHz. 0.11db in 1db steps and 10-110 db in 10db steps. Comprises a connected set of types 8494b & 8496b with 11716A rigid interconnect kit. Type N(f) connectors.HP 8494B 11 x 1dB 18GHz Coaxial Step AttenuatorHp,8494b AUDC~18GHz. 0~11db in 1db steps. 1W average power handling. Option 001. Type N(f) connectors. HP 8495B 70dB x 10dB Coaxial Step AttenuatorHp,8495b AUDC~18GHz. 0~70db in 10db steps.HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dBHp,8494/5b AU/MYDC~18GHz. 0~11db in 1db steps. 11~81db in 10db steps. Comprises a connected set of types 8494b & 8495b. Type N(f) connectors.HP 8495D 70dB 26.5GHz Step AttenuatorHp,8495D AU/MY70db step attenuator in 10db steps. Frequency range dc~26.5GHz. Max continuous power 1W. Note attenuator uses 3.5mm connectors.

Page 36: 2007 Rentalsolutionsguide-Aunz Low

26

RF & MICROW

AVE

HP 85021A RF Directional BridgeHp,85021A AUFor Hp,8757A scalar network analyser.HP 11667A Power SplitterHp,11667A AUFor Hp,8757A scalar network analysers, dc~18GHz, 0.5W max. N (F) connector on all ports.HP X281A WR-90, 1-079 to N(F) AdaptorHp,x281A AU8.2~12.4GHz waveguide to type N (F) adaptor.HP P281B-013 WR-62, 1-089 to Coax AdaptorHp,p281b AU12.4~18GHz waveguide to type N(f) adaptor.HP S281A WR-284 to N(F) AdaptorHp,S281A AU2.6~3.95GHz waveguide to type N (F) adaptor.RF Connector Kit N, BNC, TNC, SMA, APC7TR,RF-CONN AURF connection adaptors. Comprises 10 couplers with interchangeable connectors; 3 x N, bNC, SMA, & 1 x TNC, all (M) & (F). Includes ApC~7 to N (F) adaptor.

HP 11692D Dual Directional CouplerHp,11692D MYFrequency range 2~18GHz.HP 778D Dual Directional CouplerHp,778D AUFrequency range 100MHz~2GHz.HP 908A Coaxial TerminationHp,908A AUDC~4GHz. Max power 0.5W average.HP 11852A Min Loss Pad 50 ~75ΩHp,11852A AULow SWR min loss pad for use with 50Ω network analysers or other instruments to allow connection to 75Ω cables and devices.Radiall R-404850 RF TerminationRAD,R-404850 AURF load. 100W, 50Ω, dc~4GHz. Type N (M).Flann 1713320 Waveguide Directional CouplerFLA,1713320 AU20dB.

rf acceSSOrieS

Krohn-Hite 3550 Bandpass FilterKRO,3550 AUband pass, band reject, low pass, high pass filter. Frequency range 2Hz~200kHz. bandwidth 2Hz~3MHz. Max attenuation 62db. Slope 24db per octave.

filterS

BIRD 25-A-MFN-10 10dB 25W 4GHz ATTENUATORbIR,25A-10 AURF Attenuator, DC~4GHz, 10db, 25W, .Bird 808 RF Co-axial Resistor 25W 50ΩbIR,8080 MY50Ω, 25 W, DC-3500MHZ. Dummy Load.

Narda 705-69 69 x 1dB GHz AttenuatorNAR,705-69 MYStep Attenuator. 0 - 69db in 1db steps. Frequency range DC - 18GHz

rf attenuatOrS

Tektronix ASG100 Audio GeneratorTEK,ASG100 MYDual CH for stereo applications. balanced i/p & o/p. Connects in-line for easy test signal insertion. Quick identification of insertion pt with voice ID. Short duration audio test sequence for rapid automatic checkout of audio lines. Single button selection of line-up tone. Manual mode allows selection of freq & amplitude. RS-232 for remote control.

Genrad 1390B Random Noise GeneratorGR,1390-b AU/MYFrequency range 5Hz~5MHz, range selectable 20kHz, 500kHz & 5MHz. Output level 3V, 2V, 1V for each frequency range respectively. Gaussian output. Frequency response 1db, 20Hz~20kHz. pink noise filter optional.

lf Signal generatOrS

HP 8903B-010-051 Audio AnalyserHp,8903b AUAudio analyser for communications and other applications. Measures distortion, sinad, signal-to-noise, ac V, dc V, frequency. Low distortion programmable sine wave source. Frequency range 20Hz~100kHz. Optional 400Hz high pass and CCITT weighting filters fitted.

Trend Type 3 Distortion GeneratorTRE,TYpE 3 AUDistortion generator.

diStOrtiOn analySerS

LOW FREQUENCY

Page 37: 2007 Rentalsolutionsguide-Aunz Low

tv teSt equipment

>NEW Rohde & Schwarz EFA TV Test Receiver 43

RS,EFA43 AUDVb-T test receiver, fully compatible with the ETS300 744 standard, receives, demodulates, decodes and analyzes OFDM (orthogonal frequency division multiplex) signals. All key parameters for demodulating the receive signal can be selected automatically or manually. Features, 7MHz SAW filter. 6MHz, 7MHz or 8MHz operating bandwidth. 2K or 8K OFDM modulation. QpSK, 16QAM or 64QAM constellation diagram. 1/2, 2/3, 3/4, 5/6 or 7/8 code rate. 1/4, 1/8, 1/16 or 1/32 guard interval. Hierarchical demodulation. Reed-Solomon error correction 204/188.

>NEW Promax TV Explorer Prodig-5

pRO,pRODIG-5 AUFor the installation, maintenance and surveillance of terrestrial, satellite and cable TV systems. Automatically provides information about the channels available in the network and their quality. Displays analogue and digital channel picture. Includes a high resolution spectrum analyser function and MPEG decoding. Foxtel approved.

Promax Prolink 4C Premium Analogue/Digital TV Test SetpRO,pROLINK4C-pREM AUMeasures terrestrial, satellite and cable TV systems including analogue and digital VHF & UHF bands. built in colour monitor provides measurement readout and can be used to display video signal. Measurement functions include spectrum analysis, direct signal level readout, carrier to noise, channel power, digital carrier to noise, digital bit error ratio (BER) and digital QAM constellation. DVb digital TV channel identifier. Logs to pC and includes software for remote control and channel plan management.

Tektronix 1741 Vectorscope/Waveform MonitorTEK,1741 AUpAL waveform monitor and vectorscope for television and video use.Unaohm S20 & Datum 10 Digital TV Meter Combo MeterUNA,DATUM10-S20 AUComprises S20 Satellite digital and analogue television bit error rate meter and Datum 10 terrestrial digital and analogue television instrument.

Barco Quasar ModulatorbAR,MODULATOR AUDigital television signal converter. Rack mounted. Supports a full range of variable data rates, signal bandwidths and constellations. Complies with ITU-TJ.83 standards, annex A (DVb), b (open cable) & C Japan. ASI input interface (with active loop-through). Variety of input interfaces available. bit stuffing on/off and pCR re-stamping. Static pID filtering. Tuneable or fixed output RF frequency. IF loop. Front panel RF testpoint (-20db). 60dbmV (rms) output level. Front panel LCD and buttons for easy set-up. Full remote control and diagnostics with ROSA management. back-up and automatic level control available with ROSA.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 27

TELE

VISI

ON T

EST

EQUI

PMEN

T

Page 38: 2007 Rentalsolutionsguide-Aunz Low

>NEW Nettest Lite 3000E Signalling Analyser for Telecommunications Systems

GNE,L3000E-ND AUSimultaneous monitoring in both directions of 2Mb/s pCM lines. Tests framed Nx64 Kb/s & unframed 2Mb/s pCM systems. Remote operation with MS Windows. Frame Relay installation testing, trouble shooting & decode. All-layer protocol analysis and decode options for ISDN. ISDN Call Emulation option provides the necessary functionality for testing ISDN connections, can setup and receive ISDN calls with user-specified parameters.

Anritsu ME538MLA TX & RX Microwave Link AnalyserANR,ME538M AUMeasures group delay, modulator/demodulator linearity & sensitivity, differential gain & phase, IF/bb amplitude response, IF/bb return loss, frequency spectrum & deviation, am to pm conversion coefficient, power, gain attenuation and dc characteristics. Features: LED display, autorange CRT, push button parameter selection and remote monitoring. 70/140MHz bands: 83.333, 250, 500kHz & 2.4, 3.58, 4.43, 5.6, 8.2, 12.39MHz.Nettest EPE06/7 2,8,34,140 MPPS BERTGNE,EpE06/7 AUpCM bERT tester for 2, 8, 34 & 140 Mb pCM systems. performance according to G.821 with BNC type connectors. For unbalanced inputs.Nettest MPA7400 Multichannel Signalling Protocol AnalyserGNE,MpA7400 AUMultichannel telecom protocol analyser for detailed analysis of signalling systems such as SS7. Able to analyse 4 channels at the same time. Some emulation capability. Additional protocol decodes available on request. Unit is currently set up to handle signalling analysis for cellular telephone exchanges.Trend Aurora Sonata BRA/PRI ISDN Test Set TRE,AURORA-SONATA AUbRI/pRI/pOTS test set. provides simulation and monitor capabilities for Primary Rate, Basic Rate, and POTS services. Provides decoding of ETSI ISDN protocols. Has S,U,E1 and RJ11 pOTS interfaces. battery operated hand held device.W&G/Acterna IBT-10U Basic Rate ISDN Test SetWG,IbT-10U AUperforms bERT, protocol analysis to level 3 includes both S & U interface. Features include: NT simulation, telephone and tracer function, x.25 on D channel and B channel, measurement of supply voltages.Nettest Lite 3000E Signal AnalyserGNE,L3000E AUSignaling analyzer for telecommunications systems. Framed Nx64 Kbps and unframed bERT testing, in-service and out-of-service error performance measurements G.821/G.826/M.2100. balanced and unbalanced interface. Has functionality for G.703, AbIS, SS7, and ISDN for use in both wired and wireless (cellular GSM) applications. Provides comprehensive test and measurement of data transmission lines on RS232/V.24 async & sync, x.21/V.11, V35, RS422/485/449/V.36, RS-530, DCE or DTE. Detailed analysis and graphical representation on large colour display. Remote operation with MS Windows.

Digital Lightwave NIC 2.5G STM16 2.5Gb SDH Test SetDLW,NIC2.5G AUPortable analyser with touch screen PC. Testing at SDH rates of STM0/1/4/16 (52,155,622Mb/s & 2.5Gb/s). Tests pDH at E1,E3, E4, DS1 & DS3 (2,8,140,1.5 & 45Mb/s). Dual wavelength (1310/1550nm). SC Optical connectors. Tests include BERT, level, protocol decoding & analysis and ATM analysis. Complete in portable hardcase.Digital Lightwave NIC10G STM16/64 SDH AnalyserDLW,NIC10G AUNetwork information computer. Verifies and qualifies the performance of OC-192c/OC-48c SONET, STM-64/STM-16 (10/2.5Gbps) SDH and DWDM telecommunications networks. Optical interfaces (1550/1310nm for STM16 & 1550nm for STM64). Includes concatenated payload support and OC-48/STM-16 add/drop. 10.4” active matrix touch screen GUI operation. Measures optical power and frequency. pCMCIA slots for memory cards and peripherals.

Digital Lightwave NICPlus 10G SDH Tester with Gb EthernetDLW,NICpLUS10G AUportable Gb/OC-192/STM-64 Network Information Computer (5 slot chassis). Multirate interface for STS-1 OC-1/3/3c/12/12c/48/48c STM-0e/1e/0/1/1c/4/4c/16/16c and interface for OC-192/192c STM-64/64c with the ability to monitor down to the STS-1/STM-0 level inside of any supported optical rate. Use to verify & qualify the performance of SDH & DWDM & GbE telecomm networks. Electrical & optical interfaces (1550nm for 10G, all other rates 1310/1550). Includes concatenated payload support & OC-48/STM-16 add/drop. G.709/975 OTU 1 / OUT 2 FEC software installed 10.4 inch active matrix touch screen GUI operation. Measures optical power and frequency. pCMCIA slots available for memory cards and peripherals.Fluke 990DSL CopperPro Telecom Line & DSL Test Set AnalyserFLU,990DSL AUCopperPro wide range Plain Old Telephone Services (POTS) fault location and line qualification capabilities. Includes Wideband/TDR option which adds high frequency transmission testing and qualification functions for services like ADSL, HDSL, HDSL2, HDSL4, ISDN, T1, E1 and DDS. TDR feature adds precise fault location and analysis. Includes TN2100 remote terminator.

W&G/Acterna ANT 20 SDH/PDH AnalyserWG,ANT20 AUInterfaces for pDH data streams at 2, 8, 34, & 140Mb/s, electrical and optical interfaces for SDH at STM1 (155Mb/s). Jitter and wander generators and analyser options are fitted. Internal PC with FDD for transferring results. Serial, parallel, keyboard and pen interfaces.Aegis GPset Telecom Pair ID & IntercomAEG,GpSET AUFor telecommunications cable work. Typically used by Telstra contractors. Intercom function available on live or unpowered lines.

telecOmmunicatiOnS

28

DATA, NETWORK & TELECOM

MUNICATIONS

Page 39: 2007 Rentalsolutionsguide-Aunz Low

>NEW Fluke Networks Etherscope Gigabit W-LAN Analyser

FLU,ETHERSCOpE-WLAN AUEtherscope extended kit full duplex 10/100/gigabit LAN & WLAN 802.11a/b/g analyser. Handheld analyser for discovery of network elements and fault location. Discovers devices by Ip subnets, NetbIOS domains, and Ipx networks. VLAN discovery shows interface status, connected host details, and trending data. Allows measurement of device details and statistics. Complete with cable ID accessory for tracking cable routes.

>NEW Fluke Nettool LAN Analyser

FLU,NETTOOL AUVoIp monitoring. bi-directional LAN test tool. Diagnose VoIp phone boot-up problems, call control and measure key call quality metrics. Compatible with IP phones employing either SIP or SCCP call control protocols. VoIP Log displays call control events, QoS configuration, and call quality metrics. boot Log displays key boot events such as DHCp address acquisition, DNS lookup of call servers and gateways, downloading of operating files, and call server registration. Inline testing of LANs at the workstation level. Tool is plugged in-line between workstation and LAN. provides indications of NIC and hub functionality, cable connectivity, and protocol compatibility between LAN and workstation. Use as a first line fault finding tool for IT departments.

Airmagnet Portable 802.11 a/b/g Survey SystemAIR,AIRMAGNET-SURVEY AUportable wireless network survey tool for 802.11a, 802.11b and 802.11g wireless networks (5 & 2.4GHz). provides mapping of wireless network coverage with optional GpS location facility. pre-loaded on laptop computer with approved wireless network card.

Airmagnet Portable 802.11 a/b/g Wireless Network AnalyserAIR,AIRMAGNET-TRIO AUportable wireless network analyser for 802.11a, 802.11b and 802.11g wireless networks (5 & 2.4GHz). Validates WEp, 802.1x, LEAp, TKIp, MIC, VPNs. Provides security policy validation and intrusion detection. Detects denial of service attacks. provides active performance analysis and identifies and pinpoints WLAN Faults. Includes Find Tool for tracking down rogue devices and 70+ configurable alarms with expert advice. pre-loaded on p3 notebook computer.

Airmagnet Portable Wireless Network AnalyserAIR,AIRMAGNET-pRO AUValidates WEp, 802.1x, LEAp, TKIp, MIC, VpNs. provides security policy validation and intrusion detection. Detects denial of service attacks. provides active performance analysis and identifies and pinpoints WLAN Faults. Includes Find Tool for tracking down rogue devices and 70 + configurable alarms with expert advice. built-in site survey utility with GpS support. Fluke Networks Etherscope Gigabit LAN Analyser FLU,ETHERSCOpE-Ex AUEtherscope extended kit full duplex 10/100/Gb LAN analyser. Handheld analyser for discovery of network elements and fault location. Discovers devices by Ip subnets, NetbIOS domains, and Ipx networks. VLAN discovery shows interface status, connected host details, and trending data. Allows measurement of device details and statistics. Complete with cable ID accessory for tracking cable routes.

Fluke Optiview Pro Gigabit 10/100/Gigabit LAN AnalyserFLU,OpTIVIEW-GIG AUFLU,OpTIVIEW NZprovides network analysis on 10/100/Gigabit Ethernet networks (multimode fibre & copper). Active discovery in switched networks, full 7 layer analysis, fully automatic Ip configuration even without DHCp, address-to-name mapping, packet capture and decode, SNMp device analysis, RMON II traffic analysis. Gigabit testing capabilities, and basic cable testing (wiremap, return loss, etc).HP J3446C 10/100 Ethernet AnalyserHp,J3446C AUHas RJ45 and AUI ports. AUI ports allow fibre or co-ax connections to be made with appropriate adaptor (adaptor not supplied). For use with HP internet advisor undercradles for FDDI or similar analysis.

lan analySerS/management

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 29

DATA

, NET

WOR

K &

TELE

COM

MUN

ICAT

IONS

Page 40: 2007 Rentalsolutionsguide-Aunz Low

Network problem solver? Meet your new assistant.

N E T W O R K S U P E R V I S I O N TM

Introducing the EtherScope™ Network

Assistant – your eyes into the network to

help you spot problems and solve them

faster than ever. You don’t have time for trial

and error. Or methods that only provide part

of the picture. That’s why Fluke Networks’ new

EtherScope analyzer, with its immediate

discovery and fast diagnostics, helps you

quickly isolate urgent problems on your gigabit

network as well as those nagging issues that

may be keeping it from performing at optimum

level. Fast. Accurate. EtherScope.

Your network assistant is waiting to show you what it can do to help make your job easier. Just go to www.flukenetworks.com/EtherScopeand take a tour of the virtual demo.

EtherScope™Network Ass istant

HP J2524A FDDI Under CradleHp,J2524A AUFor the Hp,J2302A or Hp,J2523A/b. Includes Tp/pMD on STp/Db-9 or UTp/RJ-45, 32Mb data.HP J2523A Ethernet/Token LAN AnalyserHp,J2523A AUHoused in a ruggedised laptop style colour computer. Includes Hp’s latest Drill Down Expert Software.Network General Sniffer - Ethernet /Token RingNG,SNIFF-COMb AUHoused in a colour Toshiba T6600. Analyser provides 3 applications for network analysis and monitoring. protocol interpretation for over 140 protocols, monitoring features, and expert analysis to help identify LAN problems. Oracle database decodes also available.Network General 10/100Mb/s Ethernet Protocol AnalyserNG,SNIFF-10/100 AU10mbps and 100mbps Ethernet protocol analyser for 10/100 baseT networks. Unit supplied with RJ45 connections only.Network General Sniffer WAN InterfaceNG,SNIFF-WANpOD AUEnables the Network General Sniff-pro98 to perform WAN as well as LAN analysis. With interface and cables for RS232/V24, V35, RS449/422 and x.21. Must be used with NG,SNIFF-pRO98. performs E1/ISDN primary rate analysis.

W&G/Acterna DA-30 Dual Protocol AnalyserWG,DA-30 AUEasy to use Windows-based interface with in-built trackball. provides measurement of physical characteristics of interfaces, protocol analysis of LAN and WANs, testing of LAN/WAN interconnection devices, simultaneous analysis of any combination of LANs and WANs. Ethernet and Token Ring interface complete with all major layer protocol suites. WAN configuration: V.35, x.21 with “high speed” WAN feature module allowing speeds up to 2Mbps. Includes 16/4Mbps Token Ring interface, Ethernet,HS-WAN, V35-V28 & x21 interfaces. pAM module included.W&G/Acterna Domino GigabitWG,GIGAbIT AUFor monitoring, troubleshooting, and simulation of Gigabit Ethernet networks. provides full line rate, full duplex analysis of Gigabit Ethernet networks. All transmit, capture, filtering, and statistics are provided at full line rate. Expert analysis software provides easy diagnosis of network faults, and decodes over 300 protocols. Link configuration status is detected automatically and equipment auto configures itself to suit the detected status. Provided with hot swappable modules for single mode and multi mode fibre interfaces (Lx & Sx interfaces). Complete with laptop computer configured for the analyser.

lan analySerS/management

30

DATA, NETWORK & TELECOM

MUNICATIONS

Page 41: 2007 Rentalsolutionsguide-Aunz Low

Nettest Winpharaoh LAN/WAN AnalyserGNE,WINpHARAOH AUCapable of 10/100Mbps ethernet and up to 2Mb WAN with the following interfaces: V.35, RS-232, RS-449, EI and V.11. pRI and bRA ISDN ability. Report writing software installed for quick overview of network status.Nettest Winpharoah 2 LAN/WAN AnalyserGNE,WINpHARAOH2 AUCapable of 10/100Mbps Ethernet and up to 2Mb WAN with the following interfaces: V.35, RS-232, RS-449, and V.11/x.21. Has bERT testing for WAN. Report writing software installed for quick overview of network status.Spirent/Netcomm Smartbits SMB200 Router TesterSpI,SMb200-10/100 AU4 port 10/100 ethernet/STM1 ATM system for determining router performance including latency, latency variation and jitter. Can be used to load network with specific definable traffic to determine routing performance and discover throughput bottlenecks. System includes 4 x ML7710 10/100 interface cards.

Spirent Netcomm Smartbits SMB600 MainframeSpI,SMb600 AUMainframe for router test system for determining router and network performance including latency, latency variation and jitter. Can be used to load network with specific definable traffic to determine routing performance and discover throughput bottlenecks. Supplied with standard software and 30 version of Smartflow application. Requires appropriate interface cards.Spirent Smartbits LAN-3101A interface for SMB600/6000 ChassisSpI,SMb600-3101A AU

Spirent Smartbits LAN-3201B Gigabit card for SMB600/6000SpI,SMb600-3201b AU

Spirent Smartbits LAN-3310A 2Port Gigabit Card for SMB600/6000SpI,SMb600-3310A AU

Spirent Netcomm Smartbits SMB6000 MainframeSpI,SMb6000 AU12 card Mainframe for router test system for determining router and network performance including latency, latency variation and jitter. Can be used to load network with specific definable traffic to determine routing performance and discover throughput bottlenecks. Supplied with standard software and 30D version of Smartflow application. Requires appropriate interface cards.

lan/Wan analySerS

Wan analySerSHP 4951C 19.2Kbps Protocol AnalyserHp,4951C AUSerial data and protocol analyser. 50~19,200 baud data transfer rates for monitoring, simulating and triggering. Data codes: ASCII, EbCDIC, bAUDOT, six bit transcode (SbT), IpARS and EbDIC. protocols: x.25. bSC, HDLC, SDLC, IpARS and user definable. Error checking: CRC-CCITT, CRC-6/12/16, LRC, parity and block error rate testing (bERT), 5, 6, 7 or 8 bit per character parity, 1,1.5 or 2 stop bits. Full ASCII keyboard, up to 63 triggers, 32kb buffer memory, 618kb integral microfloppy drive, video output, separate printer output. Complete with Hp,18179A RS-232C/V24 interface with full breakout box.HP 4957A 64Kbps Protocol AnalyserHp,4957A AUprotocol analyser. For up to 64kb/s (option included for asynchronous 8-bit and NRZ/NRZI bit oriented protocols up to 256 kbps). protocols include ISDN Q.921, x.25, SDLC, HDLC, IpARS, bSC, ASYNC, and most character synchronous protocols, (option included for x.21). bERT function. Data codes ASCII, EbCDIC, bAUDOT, 6 bit transcode (SbT), IpARS, EbCD and HEx. 32 kb non-volatile memory, 786 kb volatile memory, 613kb microfloppy, 128kb non-volatile RAM disk. Complete with RS-232C, RS-449 and V35 interfaces, printer and video outputs.Nettest Fastnet ProbeGNE,Fp1601SR AUFastnet probe for Frame Relay. Provides monitoring and statistical information for Frame Relay Networks. Complete with interface cable and management software.

HP J2302A 2Mbps WAN AnalyserHp,J2302A AU/NZWAN analyser from 50b/s~2.048Mb/s. Internet Advisor CEpT-E1 and V series WAN protocol analyser. Includes; RS232/V24, V35, RS449, and CEpT-E1 analysis to 2Mb/s with bNC connectors. ISDN primary rate analysis available with Hp,18284A pod. Full monitor and decoding of major protocols over any channel. Fractional channel or full CEpT-E1. Complete English decodes with customizable displays, real-time stamp for captured data or statistics, 100ns resolution. Extensive data-filtering capability. Real-time statistical analysis, including LAN traffic analysis over WANs. 100% capture performance during full line loading. Simultaneous decodes, statistics, triggers, and filters. Log to hard disk. Full bit Error Rate tests to 2Mb (including G.821). Over 150 pre-written test included.HP J2302B 2 Mbps WAN AnalyserHp,J2302b AUInternet advisor. WAN analyser from 50b/s~2.048Mb/s. CEpT-E1 and V series WAN protocol analyser. Includes: RS232/V24, V35, RS449, and CEpT-E1 analysis to 2Mb/s with bNC connectors. ISDN primary rate analysis available with Hp,18284A pod. Full monitor and decoding of major protocols over any channel. Fractional channel or full CEpT-E1. Complete English decodes with customizable displays. Time stamp for captured data or statistics, 100ns resolution. Extensive data filtering capability. Real time statistical including LAN traffic analysis over WANS. 100% capture. performance during full line loading. Simultaneous decodes statistics, triggers, and filters. Log to hard drive. Full bit Error Rate tests to 2mb/s (BERT) including G821. Over 150 prewritten tests included.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 31

DATA

, NET

WOR

K &

TELE

COM

MUN

ICAT

IONS

Page 42: 2007 Rentalsolutionsguide-Aunz Low

lan cable teSterSFluke DTX1200 Category 6 Cable Certification TesterFLU,DTx1200 AU/NZCable certification tester. Tests up to 350MHz; Cat6 Autotest time of 12s. Comes complete with latest cat6 pM-06 peronality modules. Linkware pC software, and USb cable. Internal memory stores 350 tests. Optional memory card stores 2,000 tests.

Fluke DTX1800 Category 7 Cable Certification TesterFLU,DTx1800 AU/NZCable certification tester up to 900MHz; Cat6 Autotest time of 12s. Comes complete with latest cat 6 pM-06 personality modules, Linkware pC software, and USb cable. Internal memory stores 350 tests. Tests to Cat 3, 4, 5, 5E, 6 & 7. Included Cat6 heads will test up to category 6. Optional memory card stores 2,000 tests.

>NEWFluke DTX 10 Gig copper Testing and Certification Kit

FLU,DTx-10G KIT AUUsed in conjunction with the FLU,DTx1800. Enables testing and certification of twisted pair cabling for 10 Gigabit Ethernet deployments - whether it is an existing Cat 6 or newly installed augmented Cat 6 cabling system. Measures the performance for 10 Gig and Alien Crosstalk (ANExT and AFExT) in full compliance with the industry standards to 500 MHz.

Fluke DTX-MFM Multimode Fibre Adaptor for DTX Cable AnalyserFLU,DTx-MFM AUDTx1200/1800 multimode fibre interface. Tests fibre installations in local area networks. Fits in the slot on the back of DTx cable analyser (standard copper cable adaptors can be connected but not used simultaneously). provides fibre testing and certification. bi-directional testing at 850nm & 1300nm at the same time. Measures optical power loss, length, and propagation delay for multimode fibres. pass/fail results based on common fibre standards. SC optical connectors. Includes in built visual fault locater. (VFL)Fluke DTX-SFM Singlemode Fibre Adapter for DTX Cable AnalyserFLU,DTx-SFM AUDTx1200/1800 singlemode fibre interface. Use for testing fibre installations in local area networks. Fits in the slot on the back of DTx cable analyser (standard copper cable adaptors can be connected but not used simultaneously). provides fibre testing and certification. bi-directional testing at 1310 nm and 1550 nm at the same time. Measures optical power loss, length, and propagation delay for multimode fibres. pass/fail results based on common fibre standards. SC optical connectors. Includes in built visual fault locater. (VFL)Fluke DSP Personality Module for DSP4X00 seriesFLU,DSp-pM AUpersonality module for Fluke DSp4x00 cat6 permanent Link heads. RJ45 connector sets (pM-01, pM-06, pM-25) include 2 modules. block connector sets include one module (pM-12b, pM-13b). Modules available include pM-06 (most systems), pM-25 (most unshielded systems), pM-01 (legacy), pM-12b paduit GIGA-pUNCH 110 block, pM-13b Siemon S210 block.Fluke Networks CableIQ Cable & Network Identification ToolFLU,CAbLEIQCableIQ cable and network tester for twisted-pair, coax, and audio cabling. Allows troubleshooting connectivity problems and qualify cabling bandwidth to see whether an existing cabling link is qualified to support 10/100, VoIp or Gigabit Ethernet. Discovers what is at the far end of any network cable. Detects speed and duplex settings of attached switches and PCs. Intelligent wiremap graphically shows distance to faults (e.g., pin 1 break at 31m). Can also test cable set-up for audio application (intercom/pA). Hand held and lightweight, powered by 4 x AA Alkaline batteries. Can be used as a signal source for optional Intellitone cable tracer.

32

DATA, NETWORK & TELECOM

MUNICATIONS

Page 43: 2007 Rentalsolutionsguide-Aunz Low

fibre OpticS

>NEW Fiber Video Display Scope

FLU,FT330 AUHandheld battery operated video scope for fiber inspection.

>NEW Fiber Inspection Video Probe X 250 Magnification

FLU,FT350 AUConnects to a FLU,OpTIFIbER or FLU,FT330 to let you inspect the ends of fiber optic connectors. 250 x magnification reveals dirt, scratches, and other defects that can cause poor performance or failures in fiber optic networks.

>NEW Fiber Inspection Video Probe X 250 & 400 Magnification

FLU,FT650 AUFibre probe for use with Fluke Optifiber OTDR or FLU,FT330 handheld video scope. Has switchable 250 and 400 times magnification.

Fluke FTK200 Optical Fibre Power Meter/Light SourceFLU,FTK200 AUComprises light source and power meter. Light source is multi-mode 850nm & 1300nm (-20dbm into 62.5µm fibre). Stability is ±0.1db per 8h at 250C. power meter has calibrated measurements at 850/1300nm multi-mode & 1310/1550nm single-mode. 6dbm~-50dbm measurement power with 0.01 resolution & accuracy of ±0.25 at 250C & -10dbm. power meter memory stores up to 500 results at each wavelength which can be downloaded to PC with supplied software (also compatible with Fluke Cable Manager used for the DSp4000/4100 series). ST connector on power meter and light source.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 33

DATA

, NET

WOR

K &

TELE

COM

MUN

ICAT

IONS

Page 44: 2007 Rentalsolutionsguide-Aunz Low

Fluke Optifibre Multi-mode OTDRFLU,OpTIFIbER-MM AUShort range multimode OTDR designed for testing, troubleshooting and certifying network cabling. 850/1,300nm, 62.5mm (100m launch cable included) & 50mm (requires launch cable) fibres with SC connectors. Attenuation deadzone 850nm: 4.5m typical, 5.5m max 1,300nm: 10.5m typical, 15m max. 3km range for 850nm & 7km range for 1,300nm. Measures insertion loss and fibre length, allows automatic and manual OTDR analysis including channel map of connectors. Included LinkWare pC software documents, reports and manages all test data. Battery operated with colour display.

Acterna OMK-6 Fibre Optic Power MeterWG,OMK-6 AU/NZOMK-6 optical power meter with multi mode and single mode light sources. Level measurement is -65~+10dbm. Measurement errors are eliminated because the power meter automatically detects the wavelength being transmitted by the light source. Single mode dynamic range with continuous wave is 58db (approx 145km @ 1310nm & 230km @ 1550nm). Multi mode dynamic range with continuous wave is 40db (approx 20km at 850nm & 50km at 1310nm).Acterna OMK-14 Optical Measurement KitWG,OMK14 MYKit consists of WG,OLS-15 (light source) and WG,OLp-15 (power meter). WG,OLS-15; 1310nm & 1550nm, o/p; 7dbm (into 9/125µm) mod frequency: 270Hz, 1kHz, 2kHz. WG,OLp-15; 800~1700nm, switchable at; 850, 980, 1310, 1480 & 1550nm. Sensor type InGaAs, suitable fiber type 9/125a~50/125µm. Mod detection; 270Hz, 330Hz, 1KHz, 2KHz. Display range -70~11dbm.Kingfisher Optical AttenuatorKIN,KI7010 AU/MY1310/1550nm single-mode including 2 interchangeable pC connector interfaces, and adaptors. Attenuation range 60db, resolution 0.05, power capability +20dBm and linearity 0.02dB. Operational modes include manual, relative, step and programme control.Kingfisher KI 6000/8000 Optical Power Meter and SourceKIN,KI6000/8000 AULight source (KI8000) and power meter (KI6000) optical fibre test set for multimode applications 1300nm & 850nm. Units have ST connectors and a variety of patch leads. Light source modules 812 & 809 fitted to KI8000. KI6000 power meter uses a germanium detector for broadband operation. power meter can be used for single-mode applications but requires a seperate single-mode light source such as the KIN,KI8022.

Nettest 6250/6025 Light Source/Power Meter 1310/1550GNE,6250/6025 AUSingle-mode light source (6250) and power meter (6025) combination. Light source is 1310nm/1550nm, -8 dbm min power output laser output. power meter and light source autoswitch wavelengths to synchronize with each other. Stores past 2 results in memory for reference. Comes in hard case. Battery operatedNettest FI720 Active Fibre DetectorGNE,FI720 AUNon intrusive fibre tool for identifying active fibres. Measures bare fibres, coated fibres, and jacketed patch cords. Gives readout of optical power level in fibre and can detect optical test tones of 270Hz, 1, & 2kHz. Measures wavelengths 800~1700nm and power levels from 0~-40dbm (±2). Insertion loss <0.5db. Note: accuracy of power measurement depends on fibre, coating, & jacketing. For accurate power measurements an optical power meter should be used.

>NEW Nettest CMA 5000 Singlemode 43/45dB OTDR

GNE,CMA5000SM-45 AUSingle mode OTDR with SC/ApC (angled) adaptor. 1310/1550/1625 dynamic range 43/45/43db. +20dbm meter and light source, and VFL (Visual Fault Locator). OTDR has built in CD-R/W and 20Gb hard drive. Dedicated touch screen and hard key user interfaces. Mains and battery operation, battery life >3h. 10/100Mb Ethernet port for network connectivity. USb ports.

Nettest CMA4000 Single/Multi Mode OTDRGNE,CMA4000MMSM AUIncludes mainframe and 850/1300nm (25/24db) multimode and 1310/1550nm (30/30db) single-mode module (module Model 4457). Instrument has built in FDD and supplied with SC/pC, FC/pC, and ST/pC connectors.Nettest CMA4000 Single/Multi mode OTDRGNE,CMA4000MM AUSingle mode and multi mode OTDR. Includes mainframe and 850/1300 nm (25/24 db) multimode and 1310/1550 (30/30 db) single mode module (module Model 4457). This instrument has built in 3.5 disc drive and is supplied with SC/pC, FC/pC, and ST/pC connectors.Nettest CMA4000 Single Mode OTDRGNE,CMA4000SM AUIncludes mainframe and 1310/1550nm (34/36db) single-mode module (module part number TD-14M25003 Model 4425). Instrument has built in FDD and supplied with SC/pC, FC/pC, and ST/pC connectors.

Nettest CMA4000 1310/1550nm (40dB) Single Mode ModuleGNE,TD-14M36003 AUFor the GN Nettest CMA4000 OTDR mainframe. Module has SC/pC & FC/pC connectors. Operating wavelengths are 1,310nm (40db) & 1,550nm (40db).

fibre OpticS

34

DATA, NETWORK & TELECOM

MUNICATIONS

Page 45: 2007 Rentalsolutionsguide-Aunz Low

fibre OpticS

>NEW Yamasaki Y16 Fibre Cleaver

YAM,Y16 AUPrecision fibre cleaver. This cleaver can be used with precision splicers for single and multi mode fibres.

>NEW Yamasaki Y80 Core Alignment Fusion Splicer

YAM,Y80 AUPrecision core alignment single and multi mode fusion splicer. Instrument is fully automatic or manual and provides a typical splice loss of 0.02 dB on single mode fibre, and 0.01 dB on multi mode fibre. The instrument has automatic environment sensors, operates from -10C to 50C, 95% humidity and operates up to 4000m. Includes a built-in heater for applying splice protectors and a splice tension tester. Front mounted colour display and can be operated from AC (176-264V, 47-63Hz), or battery.

>NEW Fitel S325A Precision Fibre Cleaver

FIT,S325A AU Can be used with precision splicers for single and multi mode fibres. Features a built in sharps collection bin which automatically stores fibre offcuts as each fibre is cleaved.

>NEW Fitel S177A Core Alignment Fusion Splicer

FIT,S177A AUPrecision core alignment single and multi mode fusion splicer. Fully automatic and provides a typical splice loss of 0.02dB on single mode and 0.01db on multi mode. Splice time 9sec. Temperature range -10~50ºC, humidity range up to 90% at 38ºC, and altitude sensors operate up to 4000m which adjust arc time and intensity as required. Includes a built-in heater for applying splice protectors and a splice tension tester (200g). Front mounted colour display. AC mains operation 100~240V, or battery (up to 70 splices). Excludes cleaver which must be rented separately.

Fitel S323B Fibre CleaverFIT,S323b AUNZUse with precision splicers for single and multi mode fibres. built in sharps collection bin automatically stores fibre offcuts as each fibre is cleaved.

Fitel S121A V-Groove Fusion SplicerFIT,S121A AUSplice loss is 0.1dB for single mode & 0.05dB multi mode. Splice time is 13s. Includes splice protector heat shrink heater and splice tension tester (200g). Operates from ac (100~240V) or battery (up to 30 splices & heatings per charge). Cleaver excluded.

Fitel S175 Core Alignment Single & Multi Mode Fusion SplicerFIT,S175 AUDefault multi-mode operation is cladding align. Fully automatic. provides typical splice loss of 0.02db on single-mode & 0.01db on multi-mode. Temperature, humidity & altitude sensors adjust arc time & intensity. Includes built-in heater for applying splice protectors. Cleaver excluded.Fitel S176CF Core Alignment Single & Multi Mode Fusion SplicerFIT,S176 AUFully automatic. Typical splice loss of 0.02db on single-mode & 0.01db on multi-mode. Splice time 13s. Temperature range -10~500C, humidity range up to 90%RH at 380C & altitude sensors (operates up to 3,658m) adjust arc time & intensity. Includes heater for applying splice protectors and splice tension tester (200g). Front mounted colour display. AC mains operation 100~240V, or battery (up to 60 splices & heat shrinks per charge). Cleaver excluded.

300M Multimode Fibre Optic Launch CableFIb,MULTI/300M AUMultimode fibre test cable. 300 metres. Anritsu MG921A 1300nm Stabilised Light SourceANR,MG921A MYUse with multi-mode/single-mode fibre of 1.3µm wavelengths. Unprecedented light o/p level & wavelength stability through use of ApC & temperature control ccts. Internal & external modulation functions are provided, permitting removal of stray light.Nettest TD-4791-CL DWDM Optical Spectrum Analyser ModuleGNE,OSA-TD4791CL AUFor dense wavelength division multiplexing applications. Can be used over optical fibre C (1,530nm~1,570nm) & L bands (1,570nm~1,628nm). Use with CMA-4000 mainframe. Resolution to 10GHz. For all WDM applications including high density of 80 channels and above.Nettest Nexus Polarisation Mode Dispersion AnalyserGNE,pMD AUFor optical C-band measurements. 55db dynamic range. For measurements on optical fibre for qualification for DWDM or analogue video applications.Noyes OFS300 Fibre Optic Cable MicroscopeNOT,OFS300 AU

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 35

DATA

, NET

WOR

K &

TELE

COM

MUN

ICAT

IONS

Page 46: 2007 Rentalsolutionsguide-Aunz Low

>NEW Fluke IntelliTone Pro 200 Kit

FLU,INTELLITONEpRO AULocate, isolate, and validate twisted pair (UTp, Cat 5e, Cat 6), coax cables (RG6, RG59, and others for CATV/CCTV), bare wire (such as speaker wire and security network wire), and Cat 3 telephone cabling. The toner also lets you validate voice and data services.

Tempo TE-508S Cable LocatorTEM,508S AU/NZTempo 508S Cable Locator for locating buried or in-wall wiring. Compact design. Provides results on buried cables to depths of 1 meter and lengths up to 300 meters. Can be used to determine approximate depth of a wire or cable before you dig. Fully adjustable transmitter output and receiver gain Transmitter frequency is 447.5KHz. Transmitter can be connected directly to AC power outlet. Transmitter runs approximately 35 hrs and receiver runs approximately 20 hrs from standard 9V batteries.

Pathfinder PF610 Circuit Tracer KitpAT,pF610 AUFor tracing concealed power cabling and other signal or data conductors. Comprises a transmitter and a detector. Transmitter when connected to a cable generates a 4.6kHz current pulse by drawing low current from the cable circuit. In the case of data and signal circuits a 9V battery can be used to power the cable. This may require disconnection of computer equipment, etc. Detector gives audible and visual indication of the signal field. Trace 1 & 3 phase cables, coax, buried unpowered cable, locate fuses, etc.Pathfinder 220 Cable Locator/TracerpAT,LOCAT220 AUFor tracing live power cables within buildings. Connection is generally made at an outlet. Transmitter has visual and audible indication. Range 3m.Haganuk Teleflex 2000 Cable Fault TesterHAG,2000 AUTime domain reflectometer for power cables. Measuring ranges : 250, 500, 1,000, 2,500, 5,000, 10,000, 25,000 & 50,000ft. pulse widths: 10, 100, 200, 1,000, 2,000 & 10,000ns. Accuracy: ±1% typical, <2% worst case. Digital display of distance. Can only work with multi-core cable with respect to between the cores or with respect to core and shield. Not suitable for finding faults to ground or between 2 separate cables.

HDW T19 15 kV Surge GeneratorHDW,T19 AUCable fault location system. For use with HAG,2000 time domain reflectometer, can be used as a stand alone instrument as a “thumper” and insulation tester. Comprises a high voltage generator with an arc reflection filter. Surge output range to 15kV. High voltage insulation test output to 40kV dc. Leakage current ranges 10µA~100mA. Use to burn faults up to 25mA continuous output. Thumper function provides 800j of energy up to 15kV up to 5s.Radiodetection Stethoscope Antenna for RAD,RD400 SeriesRAD,STETH-L AUConcave head fitted to flexible goose neck with handle. Length 480mm, head 46mmØ. Frequency range 50Hz~65kHz. Connect to any Radiodetection receiver fitted with accessory socket.Radiodetection RD500 Plastic Pipe LocatorRAD,RD500 AUOperates with 3 alternative pressure wave signal transmitters. Range 150m. Location accuracy to 25% of depth to 2m. Transmitters included to match meter base, hydrant, and tap outlets.Megger TDR1000MEG,TDR1000 AUFor cable consisting of 2 insulated metallic elements, one of which may be the armouring or screen of the cable. Internal matching networks to allow testing of 25, 50, 75 & 100 cables. Can be matched to the cable using the balance control allowing long lengths of cable to be easily tested and faults close the instrument to be seen. Propagation velocity value can be similarly adjusted to match the cable, ensuring an accurate distance measurement can be directly read. Gain of the instrument is also variable, allowing more minor faults to be identified over length of the cable. Eliminates the transmission pulse ‘dead zone’. Range 10m~3km. Display: Large high-resolution backlit [LCD]. batteries 6 x LR6 (AA), alkaline, NiCd or NiMH cells. Consumption 100mA nominal 140mA with backlight (20/30h continuous use depending on backlight use). Dust and shower proof to Ip54.Megger TDR2000 TDR Cable Fault LocatorMEG,TDR2000 NZMinimum resolution of 0.1m and a maximum range of 20km at 0.9VF and 16km at 0.65VF. perform single or dual channel measurements on a wide range of metallic cables. Active channels can be compared with each other or with previously stored traces from memory. Differential channel measurements are possible and cross talk between channels can also be identified.Megger TDR20002RM Dual Channel TDRMEG,TDR2000/2RM AURange 20km at VF =0.90. Monochrome display with backlight, dual cursor measurement, output pulse amplitude and width control. No blocking filter required for direct connection to live systems up to 300Vac. 15 memory trace storage, down loadable to PC via RS232C interface, software supplied. Ranges 50m, 100m, 200m, 400m, 1km, 2km, 4km, 8 km & 16km. Resolution 0.1m up to 200m, 0.2m up to 400m, 0.1% of range above 400 m. Measurement accuracy 0.1% of range. Input impedance 120Ω. Velocity factor variable from 0.300~0.999 in steps of 0.001. powered via rechargeable NiMH powerpack, charger supplied.Dynatel 2273 Buried Cable and Fault LocatorDYN,2273 NZFeatures include ac V meter, Ω meter, cable depth meter (non energised cables only) and multiple frequency transmitter (user selectable). Trace path of energised and unenergised cables, indicate cable depth and locate the position of shorted conductors to ground using the A frame accessory. Max depth is 2.5m.3M Scotchtrak Cable LocatorSCO,TK-6b NZShort circuit cable and circuit breaker tracer. Traces wires in walls, floors and ceilings back to the switchboard. Locates associated fuses and circuit breakers. To be used on live circuits.

cable/pipe teSterS & lOcatOrS

36

CABLE/PIPE TESTERS & LOCATORS

Page 47: 2007 Rentalsolutionsguide-Aunz Low

Tektronix 1503C TDR Cable Tester TEK,1503C AU/NZ/MYDistance range 50,000’, resolution 0.04’ & 50, 75, 93, 125Ω output impedance. LCD display. Internal battery or mains operation. Supplied with ethernet testing and isolation network options.

Tektronix 1503 Time Domain ReflectometerTEK,1503 MYTime Domain Reflectometer for long cable fault location. Display from 0~5,000 to 0~50,000 feet. Internal battery or mains operation.Tasco PTR600 Cable TracerTAS,pTR600 NZClamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2 clamp CTs without disconnecting the earth conductor. Measures the dc loop resistance without any influence from other conductors.Radiodetection RD4000 Type 7 Cable Location KitRAD,RD4000TYpE7KIT AUIncludes transmitter and locator. Receiver has 640Hz, 8, 33 & 82kHz, 2 power and radio modes. 3 locating modes. Modes, 2 peak, 1 null, location arrows, simultaneous digital depth and current readout. Transmitter T10 version, FF, 640Hz, 8, 33 & 82kHz transmission freq. LCD display for freq, power, battery and connection readout, multimeter function, cable fault find function, 10W output, high efficiency induction mode. Signal clamp 100mmØ. Connection leads and carry bag.

Radiodetection A Frame for RAD,RD4000 Type 7 KitRAD,AFRAME FORRD4000 AUA-Frame accessory for RAD,RD4000Type7KIT. For sheath to ground type fault finding.Radiodetection Flexisonde Pipe TracerRAD,FLExISONDE AUSonde for use with RD400pxL. Flexible rod on reel 50m long complete with 2 sondes. Small sonde transmitter is suitable for insertion into plastic pipes of 25mmØ & 150mm min bend radius. Can be detected at depths up to 1.5m. Larger sonde can be detected at 5m depth and is suitable for insertion into plastic pipes of 80mmØ & 210mm min bend radius. Sondes are battery operated.Radiodetection SupersondeRAD,SUpERSONDE AUCan be connected to the RAD,FLExISONDE cable if required. Detectable to 15m depth.Radiodetection 100mm Clamp AntennaRAD,CLAMp-ANT AUFor use with RAD,RD400pxL. Identify an individual cable out of a bunch. Good for cable tracing. Transmitter is connected to one end and placed around individual cables for identification. Clamp is 100mmØ.

Radiodetection RD400PXL Pipe and Cable Locator RAD,RD400pxL AUCan measure current in buried lines. Includes transmitter and locator, peak and null location by audio and meter, very useful in congested areas. Has power /radio/8kHz/33kHz modes, can read depth to 3m. Includes direct connect lead and signal clamp (tong) (10cm). Works with optional sondes to trace sewers and plastic pipes.

>NEW CScope CATXDSGV-KIT Cable and Pipe Locator

CSC,CATxDSGV-KIT AU/NZCable location tool. Includes 33kHz generator with touch button controls and LCD, xD receiver/ locator with 33kHz, power or radio modes. Direct connection cable, stake and 75mm tong set. The transmitter can operate with direct connection, tongs or induction. The instrument will also determine cable depth, range 0.2m to 3m . It will operate with the Radiodetection 33kHz sondes.

ICC LD400 Ultrasound Leak and Emission DetectorICC,LD400 AUUsed to detect water and gas leaks, from ultrasonic emission. Also used for mechanical noise location. Supplied complete with an ultrasonic transmitter to enable leaks within containers to be detected, e.g. vehicle bodies, fuel tanks. Aural and visual indication. battery operated.ICC LD408 Noise Leak DetectorICC,LD408 MYUsed to detect water & gas leaks, etc. from ultrasonic emission. Also may be used for mechanical noise location. Supplied complete with an ultrasonic transmitter to enable leaks within containers to be detected, e.g. vehicle bodies, fuel tanks. Aural & visual indication. battery operated.Ultra Probe UP100KT Ultrasonic Leakage DetectorULT,Up100KT AU/NZHand held pistol type with stainless steel sensor enclosure. Frequency reponse 20~100kHz, (centred at 28 ~42kHz), 10 segment LED bargraph (red). Sensitivity 8 precision attenuation. Response time 300ms, operating temperature range 0~500C. Kit includes contact stethoscope module with different wave guide extension rods for direct for use on pipes, bearing housings, steam traps, etc. Rubber focusing probes, head set, warble tone generator for determining leaks in seals of empty containers, etc.

Primayer Omikron Water Leak DetectorpRI,OMIKRON-AG AUWater leak locating listening probe and ground microphone system designed to locate leaks in water pipe. Supplied with headphones and interconnection cables. probe detects leak noise directly at available valves hydrants, etc. High sensitivity and wide band amplification of leak noise particularly at lower frequencies. Microphone will detect noise reaching the ground surface.

cable/pipe teSterS & lOcatOrS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 37

CABL

E/PI

PE T

ESTE

RS &

LOC

ATOR

S

Page 48: 2007 Rentalsolutionsguide-Aunz Low
Page 49: 2007 Rentalsolutionsguide-Aunz Low

ELECTRICAL POWER

Page 50: 2007 Rentalsolutionsguide-Aunz Low

>NEW Bell 5180 Gauss/Tesla Meter

bEL,5180 AUMagnetic measuring equipment, portable gaussmeter. built-in software eliminates the need for complex calibration procedures. Key features include Auto Zero, Min./Max./peak Hold, Auto Range and Relative Mode. Allows the user to select Gauss, Tesla or Ampere/Meter readings. With Hall effect transverse probe. Frequency bandwidth DC~30kHz, range up to 30kG. Analogue output (±3V FS) and USb interface. battery operated.

Arlyuna LF Milligauss Magnetic Field Strength MeterARL,GM NZHandheld ac magnetic field strength meter. Ranges 9.9mG & 99mG. Measurement bandwidth 12Hz~1.3KHz. 60Hz & 50Hz filter and analogue ac output for connection to oscilloscopes, recorders or loggers.Bell 4048 ac/dc Gauss MeterbEL,4048 NZHandheld digital ac/dc Gauss/Tesla meter. Ranges are 200~20kGauss with a resolution of 0.1Gauss or 0.02~2Tesla with a resolution of 10E-6Tesla. Accuracy is 2% +2 digits. peak hold feature. Supplied with transverse probe and zero gauss chamber.Bell 4080 ELF GaussmeterbEL,4080 AUHandheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging 0.1~511mG. probe: 3 axis technology, maintains accuracy regardless of orientation. True rms measurement. Typical accuracy error: ±2%, +1 digit. Frequency response: ±5% 40~600Hz, -3db 25/1,000Hz. Applications include detecting magnetic field emissions from overhead ac power lines, video display terminals, office equipment and household appliances. This unit is not suitable for measuring field strength of “neodymium” or “rare earth” magnets or any permanent magnets. The frequency response ± 5% 40-600Hz and -3db 25/1000Hz.Bell 5080 Gauss/Tesla MeterbEL,5080 AUPortable gaussmeter complete with Hall effect transverse probe. Frequency bandwidth dc - 20kHz, ranges 300G~30kG. Max resolution 0.1G (10µT). Max and min hold. Analogue output and RS232 interface. battery operated.

Holaday HI-3627 Magnetic Field MeterHOL,HI-3627 AUThree orthogonal field sensors. Dynamic range 0.2mG~20G. True rms detection. Frequency range 5Hz~2kHz with an in-built 30Hz high pass filter. Meets requirements of the Swedish protocol and the IEEE p-1140 protocol.Holaday HI-3604 LF E & H Field MonitorHOL,HI-3604 AU/MYLow frequency field meter. Designed to evaluate electric and magnetic fields associated with 50Hz power lines. Frequency range 30~2,000Hz. Measures magnetic fields from 0.1 milligauss to 20 gauss. Measures electric fields from 1 volt/meter to 200 kilovolts/meter. LCD display. 127 reading data memory. Meets the interim requirements of the Australian Radiation Laboratory for normal levels of AC power exposure.Hirst GM04 Microprocessor Controlled GaussmeterHMI,GM04 AUFacilities: store and recall on 0~99 samples, hold. Analogue peak with digital storage. Auto and manual ranges. Automatic reading conversion between different units. (Note 1mT = 10G) Range 1: 0~to more than 3T resolution 1mT.Range 2: 0~299.9mT resolution 100µT.Range 3: 0~29.99mT resolution 10µT.Range 4: 0~2.999mT resolution 2µT.Accuracy (at 200C): ± 1%. Frequency range: dc and 15Hz~10kHz. Functions: dc, dc peak, ac rms, ac rms max, & ac peak. Applications include measurement of magnetic flux density of magnets and assemblies, electric motor air gaps and drive actuators.Hirst Magnetic Instruments GM04 Axial ProbeHMI,GMO4AxIAL pRObE AUAxial probe for use with HMI,GM04.Teslatronics 70 milliGauss MeterTES,70 NZTri-axial ac magnetic field meter. Range is 0.1~1,999mGauss, accuracy is ±1% at 60Hz. Frequency response is 40~400Hz ±10%, 50~300Hz ±5%, 30~600Hz - 3db.Tri-axial Milligauss Magnetic Field MeterbEL,4090-20 NZHandheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging, 0.1~1999mG. Resolution 0.1mG in high-sensitivity mode & 1mG resolution in low-sensitivity mode. probe 3 axis technology, maintains accuracy regardless of orientation. True rms measurement. Typical accuracy error: ±1% + 1 digit. Frequency response: ±10% 40~400Hz, -3db, 20/2000Hz. Applications include detecting magnetic field emissions from overhead ac power lines, video display terminals, office equipment and household appliances.

magnetic field meterS - gauSS teSla

Model Type Frequency (Hz) Range (G) Electric Field OutputARL,GM AC magnetic field meter 12~1,300 9.9 ~ 99mG CRO

HOL,HI-3627 Vector AC magnetic field meter 5~2,000 0.2 ~ 20

HOL, HI-3604 AC field strength meter 50~100 0.1 ~ 20,000mG 1~200,000V/meter

TES,70 AC magnetic field meter 30~600 0.1 ~ 1,999mG

HMI,GM04

Digital gauss meter

dc~10kHz 30 ~ 30,000

bEL,4048 dc~12 200 ~ 20,000

bEL,4080 40~600 0.1mG ~ 511mG

BEL,5080 dc~20kHz 300 ~ 30,000 Analog & RS232

BEL,5180 dc~20kHz 300 ~ 30,000 Analog & USb port

bEL,4090-20 Digital ELF gauss meter 40~400 0.1 ~ 1999mG

40

ELECTRICAL POWER

Page 51: 2007 Rentalsolutionsguide-Aunz Low

Model Type VoltageV

ResistanceΩ

CurrentA

FrequencyHz Features

SEW,x3760pKIT+portable Appliance Tester

AS3760:2001 Compliant, full keyboard, barcode scanner, RS232, Automatic label/tag

printer

SEW,EUROpA pAT AS3760:2001 Compliant, barcode scanner, RS232

MEG,CBT2 RCD Tester 6~500mA

MEG,LT6 Earth Loop Impedance 20~2kΩ

LEM,SATURN GEO EASY

Soil Resistivity Tester48ac

0~20kΩ 50mA 128 Battery,RS232

LEM,SATURN GEO x 1mΩ~300kΩ 250mA 94~128 battery, Stakeless measurement, earth loop impedance,RS232

MEG,DET5/3R 0.1~19,999 128 BatteryMEG,DET20C Earth Resistance Clamp 25mΩ~1550Ω 0.2~35 battery, USb output of data

MEG,BM21

Insulation Tester

25~5000 5TΩ 2mA/kV

dc

BatteryMEG,BM11D 500,1kV, 2.5kV,

5kV 10kΩ~500GΩ

MEG,10-01-10KV 10kV 1TΩ 99µA Operates from main supply or rechargeable battery

MEG,1020-10KV DIT 50~5000 35TΩ Operates from main supply or battery

LEM,SATURNISO 50 ~ 1,000 30GΩ Battery

HIO,3455HVIT,5KV 250, 500, 1kV, 2.5kV, 5kVdc 5TΩ 1mA battery, data storage & USb

interface

HIO,3454-51-3 250, 500, 1000 4GΩ 200mA Insulation with 200mA continuity tester

HVD,HVA30-DC/VLF High Voltage Insulation DielectricsTest Set

33kV, 5µF 190hm 15mAdc/VLF

Four in one HV test setVLF/DC/Jacket Sheath/Fault

ConditioningHVD,HVA60-DC/VLF 60kV, 50mA

CHK,LM05

Micro-Ohm Meter

1µΩ~20Ω 10

dc

BatteryCRO,D07 600µΩ~60Ω 10 c/w probe/Lead Set

T&R,DSM600 67µΩ~6.6mΩ 600RS232

T&R,DSM200 200µΩ~4Ω 200/10VAL,4300b 2µΩ~20kΩ 100mA~10 Heavy duty Kelvin leads

MEG,DLRO100.1mΩ~2kΩ 10

Alpha-numeric keypad for entering test notes, autoranging with manual option, realtime or from storage via RS232, large

backlit LCD

MEG,DLRO1-10x

MEG,DLRO2000.1µΩ~999.9mΩ

10~200

MEG,DLRO600 10~600 RS232, Software

MEG,CM500Multifunction Installation

Tester280~1kV 0.01~499MΩ

0~250mA 16~460 RS232, Software, RCD tester, Loop impedance, Prospective

short circuitMEG,MFT1502 0~200mA 45~65

LEM,SATURN100+ 1~400 0.01~9.99kΩ 0~1 15.3~457 BatterybAU,DpA75

Oil Insulation Tester0~ 75kV rms RS232

AVO,OTS60pb 60kV rms Battery, RS232bJM,ALL-TEST3 Motor, Coil Tester 1 kV 0~20MΩ 100~2,400 Power Factor, Capacitance

3M,701 Megohm Meter 10 ~ 100 0~10GΩ ESD Surface TestingMEG,MIT1020-10KV DIT Insulation Resistance 1kV~10kV 10kΩ~35TΩ USb, RS232, battery

MEG,RCDT330 Residual Current Device 0~300 10mA~1kmA 25~450 USb, battery, Ip54See Also Hi-pot Testers

inSulatiOn/cOnditiOn/reSiStance teSterS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 41

ELEC

TRIC

AL P

OWER

Page 52: 2007 Rentalsolutionsguide-Aunz Low

>NEW Megger MIT1020 Diagnostic 10kV Insulation Resistance Tester

MEG,MIT1020-10KV DIT AUbacklit display, variable test voltage from 50~5000V, Automatic IR, pI, DAR, SV and DD tests, measures to 35TΩ, RS232 & USb download of results. IEEE 43-2000 recommends the use of 10kV for motor windings rated above 12kV. protection rating of Ip54. Mains or battery powered.

Megger 10-01 10kV Insulation Tester, Test Voltage 500~10,000V MEG,10-01-10KV AUThe Megger MEG,10-01-10kV Insulation Tester is a compact, Microprocessor controlled high voltage dc Insulation tester.

>NEW HV Diagnostics 30kV-15mA DC/VLF High Voltage Insulation DielectricsTest Set

HVD,HVA30-DC/VLF AU/NZVLF (0.1Hz), DC (±), cable fault conditioning (burning), and sheath/jacket testing modes all included. 0.1Hz & 0.02Hz. For solid dielectric cables such as xLpE and EpR. Fully automatic or manual cable test sequences complying with International Standards/Guides such as IEEE 400.2, VDE 0296, CENELEC, etc. True symmetrical sinusoidal, load independent, output waveform across the full load range. Real-time display of actual output waveform. Easy to use, menu guided, large backlit user interface. Large output load capability (up to 5µF). Automatic and integrated load capacitance measurement with optimum frequency selection. Storage of test results for later retrieval or download to laptop. Short circuited protected.

>NEW HV Diagnostics 60kV-50mA DC/VLF High Voltage Insulation Dielectrics Test Set

HVD,HVA60-DC/VLF AUTrue sine wave low frequency output. 0.1Hz & 0.02HZ. For VLF, DC and jacket/sheath testing. Fault conditioning capability. Test result storage capability. Short circuit protection. Complies with CENELEC, IEEE 400.2, VDE 0296 and other international standards. Manual or fully automatic test sequence selection. Real-time display of actual output waveform. High voltage power source suitable for testing electrical plant including cables: xLpE, pE, EpR, pILC etc, capacitors, switchgear, transformers, rotating machines, insulators and bushings.

Hioki 3455 High Voltage Insulation TesterHIO,3455HVIT-5KV AUpI and DAR function to check insulation quality and step voltage test to detect for signs of deterioration. Generates a wide range of test voltages, from 250V to 5kV. The voltage may be chosen from the commonly used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or decrements of 25V or 100V. Insulation diagnoses for automatic calculation and indication of pI (polarisation index) and DAR (Dielectric absorption ratio), step voltage testing and temperature correction. Large memory stores up to 100 manual records and a logging function for 10 data (360 times). Stored data may be displayed on the LCD or down-loaded to a pC. The date and time of measurement also recorded.

CHK LM05 Micro-Ohm Meter 10A CHK,LM05 AU/MYOperates from internal batteries or external power supply. Max test current 10A. Resistance range up to 20Ω with a max sensitivity of 1µΩ. Includes power supply-charger, duplex helical test leads, length 2m.Megger DLRO10 Micro-Ohm MeterMEG,DLRO10 AUSelf contained automatic micro-ohm meter, selecting the most suitable test current, up to 10A dc to measure resistance from 0.1mΩ~2kΩ on one of seven ranges. Instrument is built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, small enough to be taken into areas which were previously too small to access. DLRO10 uses a large, bright 4½ digit LED display. Resolution: 0.1µΩ. battery: rechargeable NiMH, typical life 1,000 test at full load.

inSulatiOn/cOnditiOn/reSiStance teSterS

42

ELECTRICAL POWER

Page 53: 2007 Rentalsolutionsguide-Aunz Low

inSulatiOn/cOnditiOn/reSiStance teSterSHioki Digital MΩ HiTester Insulation TesterHIO,3454-51-3 AUContinuity function with 200mA and 3 range voltage selectable 250V, 500V & 1kV. Easy to read digital display, auto-discharge, live-wire warning, safety system for high voltage measurement, sliding cover. back-lighting liquid crystal display for easy reading in dark areas, checks ground wire continuity with a short circuit current of 200mA. Capable of testing the continuity of electrical facility grounds in accordance with IEC 60364. Measurement range insulation resistance maximum 4000MΩ @ 1kV. Other functions:- insulation and low resistance mode - comparator, measurement value hod, insulation resistance mode - auto discharge, insulation and ac voltage mode - live wire warning (when voltage of 70V+ or -10V exists across measurement terminals). Low resistance mode - zero adjust. All measurement modes - battery indicators, auto power off. Maximum rated working voltage 600Vac.

RCD Isolation Test Transformer for Testing Portable RCD UnitpRO,ITx125VA-RCD AURCD Isolation Test Transformer for Testing portable RCD units. Input 240V 50Hz and output 230V 125VA thermally protected isolation transformer. This is only suitable for testing portable RCDs and by using this isolation transformer will avoid tripping of the whole circuit. It comes with 15Amps Australian / New Zealand Socket. Isolation test transformer can be used to test up to 150mA trip currentCropico DO7 Micro-Ohm Meter complete with Probe/lead SetCRO,DO7 AULow resistance measurement for use in workshop, field or test facilities. Rugged construction, in a sealed plastic case with lid and carry handle. Advanced features including protection up to 415V rms at the measuring terminals, digital calibration and long scale length, 6,000 count. Rechargeable batteries >1h of continuous operation on lowest ranges, & 20h on all others. Battery charge indicators are provided. Internal charger will boost charge to 90% of full charge, switching automatically to a maintenance charge. Warning LEDs illuminate when an open circuit lead condition is detected. RS-232 output for connection to an external printer or pC. plug is provided for the connection of external start switch, eg. foot switch. Supplied with batteries, mains cord and test leads. For special lead sets we offer a variety of different styles, together with calibration standards.

Megger DLRO-10X Digital Low Resistance OhmmeterMEG,DLRO-10x AU/NZAutomatically selects the most suitable test current, (up to 10Adc) to measure resistance from 0.1µΩ~2kΩ on 1 of 7 ranges. Real-time download of results and on-board storage for later download to a pC. Automatically detects continuity in potential and current connections. Visible warning of high voltages present at the terminals. Visible warning of current flowing in the test sample. Multiple operating modes including fully automatic. Alpha-numeric keypad for entering test notes. User selectable high and low limits. Autoranging with manual option.

Megger DLRO600 Digital Micro-Ohm Meter- High currentMEG,DLRO600 AUMeasures resistance between 0.1µΩ & 1Ω at high currents. provides test currents from 10A~600A subject to the load resistance and supply voltage. backlit liquid crystal display shows information needed to perform a test; all test parameters and measurement results are displayed. Range: 0.1µΩ~999.9mW [subject to supply voltage and load resistance]. Accuracy: voltage ±0.5%, ±0.1mV, current ±0.5%, ±0.1A. Resistance: better than µΩ~100mW. power supply for full output: 207~265V 50/60Hz with a load less than 7mΩ including current leads [i.e. standard 5m 50mm² current leads only, 4mΩ load]. Reduced output: down to 100V 50/60Hz. Test current range 10A~600A unsmoothed dc in 1A steps, accuracy ±2%, ±2A. Test Modes manual, auto, continuous. Test Time 7s NORMAL /AUTO mode. Refreshed every 2s in CONTINUOUS mode. Voltmeter input impedance >200kW. Data Transfer real time or batch download via RS232 using AVO Download Manager. Storage Capacity 300 result sets and memo, battery backed for 10y.Megger 200A Micro-Ohm DLRO200MEG,DLRO200 AUDigital low resistance micro-ohm meter 200A.

T&R DSM200 200A Micro-Ohm MeterT&R,DSM200 AUMax 200A. Max resolution 0.1µΩ. Digital display with RS232 output. AC mains operation. Complete with 3m leads.T&R DSM200 600A Micro-Ohm MeterT&R,DSM600 AUMax output 600A max resolution 0.1µΩ. Digital display with RS232 output. AC mains operation. Complete with 3m leads.Valhalla 4300B Digital Micro-Ohm Meter VAL,4300b AUSelectable current ranges 100µA~10A. Suitable for large electrical machinery. Resistance ranges 2mΩ~20KΩ with a max resolution of 0.1µΩ. basic accuracy 0.03% with a 4½ digit display. Supplied with heavy duty Kelvin leads.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 43

ELEC

TRIC

AL P

OWER

Page 54: 2007 Rentalsolutionsguide-Aunz Low

MEGGER - A4 advert 12/10/06 4:04 PM Page 1

Page 55: 2007 Rentalsolutionsguide-Aunz Low

Megger BM21 500V/1/2/5kV Insulation Test SetMEG,bM21 AUTest voltages 25~5,000V in 25V steps. Insulation range to 1TΩ at 500V, 5TΩ at 5kV. AC/dc voltage measurement 50V~1kV. Leakage current measurement. Capacitance measurement at end of test. Automatic discharge of capacitance. In-built test timer. Insulation burn mode - short circuit current 1mA nominal. battery life 8h, in-built charger for charging from mains or 12V dc.AVO/Megger BM11D Analogue/Digital 5kV Insulation TesterMEG,bM11D AU/MYTest voltages 500V, 1kV, 2.5kV and 5kV. Insulation range 10kΩ~500GΩ digital. AC/dc voltage measurement 50V~1kV. Timer 0~60min. Automatic discharge of capacitance. battery life 8h, in-built charger for charging from mains or 12V dc.Megger BM25 Insulation TesterMEG,bM25 AU/NZFive kV insulation tester which is battery-powered, housed in a rugged case and has a large, analogue/digital LCD. A built-in timer makes both spot tests and polarisation Index (pI) testing easier to carry out. pre-set standard test voltages at 500V, 1, 2.5 & 5kV with variable test voltage in 25V steps. Displays capacitance at the end of a test to 10µF. Performs automatic PI, Step Voltage and Dielectric Discharge tests as well as providing an optically isolated RS232 port for downloading results during a test. Short circuit current: nominal 1.8mA, max 2mA. battery life: typically 8h.

Megger CM500 Multifunction Installation TesterMEG,CM500 AU/NZCombines the function of several instruments. Non-tripping loop test for tests on RCD protected circuits. RCD ramp test features actual tripping current. Functions are insulation, continuity, loop testing, RCD tests, voltage & frequency measurement. Phase indication, outlet polarity indication. Stores approximately 750 test results in memory for uploading to PC.

>NEW Megger RCDT330 Residual Current Device Tester

MEG,RCDT330 AUTests standard, dc, selection and programmable RCDs. Ramp testing. Auto (remote) testing. 3ph safe. Enables testing on 110V centre tapped supplied. performs 1/21, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA, 300mA, 500mA & 1000mA on general and selective (time delayed) RCDs. Tough rubber armoured case with built-in cover. Weatherproof to Ip54. USb interface for downloading test result.

LEM Saturn Insulation TesterLEM,SATURNISO AUTest voltages 50~1,000V in steps of 10V. Max range 30GΩ. Measures ac/dc voltage to 600V, resistance to 30kΩ. Digital and analogue display. Battery operated.

Megger CBT2 Earth Leakage Breaker TesterMEG,CbT2 AUResidual current device (RCD)/safety switch, circuit breaker tester. Twelve ranges from 6~500mA. Displays tripping time in ms.Metrel MI 2121 AUS Advanced RCD TesterMET,MI2121AUS AUExceeds all requirements of AS/NZS3760:2003. Stores up to 500 tests. Interface RS232 Software.

Megger BT51 Low Resistance OhmmeterMEG,bT51 AUUses 4 terminal method with helical duplex dual pronged probes. Test current 2A nominal at 2Ω. Ranges 2, resolution 1mΩ, 20mΩ, resolution 10µΩ. Accuracy at 0~500C, ±1% of reading, ±2digits. Display LED 3½ digit. Power supply internal NiCd rechargeable batteries, typically around 2,000 tests at 5s duration. Re-charge time around 10h with 240Vac mains power. Nett weight 45kgs.Megger LT6 Digital Loop TesterMEG,LT6 AUEarth fault loop impedance tester 20Ω range 0.01Ω resolution, 2kΩ range 1Ω resolution. Single & 3ph systems can be tested. Used with MEG,CbT2 to test compliance to AS2381.1 (electrical wiring for hazardous areas). Tests automatically when connection to circuit is made. Neons indicate fault conditions.Megger MFT1502 Combined Insulation, Loop & RCD TesterMEG,MFT1502 AUTests fixed wiring in accordance with International and National Wiring Standards. Display digital/analogue arc LCD. Voltage measurement automatic selection ac or dc up to 270V. Continuity testing 200mA from 0.01~99.9Ω, automatic continuity testing commences the moment the test probes touch the circuit to be tested. Audible tone to confirm test. Safety check for presence of a voltage. Variable buzzer threshold selectable from 2~100Ω in 6 steps. Insulation testing 250, 500V & 1kV. Safety lockout at voltages greater than 55V. Auto discharge facility safely discharges all circuits after insulation test. Low current loop test, a 3-wire non-tripping 0.01Ω loop test designed to prevent RCD tripping. High current loop test at 25A provides a fast test where no RCD is fitted. Supply voltage and polarity indication at 55V~280V, 45Hz~65Hz phase to phase. phase~phase, phase~neutral and phase~earth loop tests are possible. Loop measurements from 55V~480V. prospective short~circuit current (pSC), a high current loop test, is provided for rapid measurement of loop currents, both at the socket outlet and distribution board. Ranges from 1A~19.9kA with a resolution of 1, 10 & 100A depending on range auto-ranging. RCD testing 10mA~1000mA with both 0 & 180O phase angle. RCD ramp test measures the RCD trip current. Displays actual trip current on all RCD ranges instead of trip time. LED torch in illuminated probe for low light level areas. Ip54

inSulatiOn/cOnditiOn/reSiStance teSterS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 45

ELEC

TRIC

AL P

OWER

Page 56: 2007 Rentalsolutionsguide-Aunz Low

Kikisui TOS-5051 5kV ac/dc Hi-Pot TesterKIK,TOS-5051 AUHigh voltage ac/dc insulation test set. Ranges 0~2.5kV & 0~5kV. Max output ac 100mA, dc 10mA. pass/fail comparator included.

>NEW Megger Digital Earth Test Clamp

MEG,DET20C AUMeasures ground resistance from 25mΩ~1550Ω . Measures ground leakage current from 0.2mA~35A. Automatic self calibration. Auto ranging. High and low alarms. Large memory. Download to Megger Download Manager. Measures earth resistance in installations such as buildings, pylons and RF transmitter sites. Use for the inspection and verification of lightning protection systems. Large jaw opening.

Megger Det5/3R Ground Resistance Tester MEG,DET5/3R AUMEG,DET5 NZChecks resistance of electrical systems including soil resistivity. Measures resistance from 0.01~19,999Ω in 4 ranges. LCD 3½ digit display. Operating frequency 128Hz. Complete with earth testing kit including spikes and wire.3M Model 701 Micro-ohm ESD Surface Tester3M,701 AUTester for static control surfaces, table mats, field service kits, floor coverings, etc. Test voltages 10 & 100V. Resistance range 0~100GΩ.Baur DAP75 Insulating Oil TesterbAU,DpA75 AUOutput voltage 0~75kV rms. Selectable programmes to international standards. Integral printer. RS232 interface.AVO OTS60PB Transformer Oil TesterAVO,OTS60pb AUTest voltage 60kV max at 61.8Hz. Fully automatic operation. Rechargeable battery operation. RS232C interface.BJM All-Test III Motor, Coil and Winding TesterbJM,ALL-TEST3 AUTester for single or polyphase ac motors, generators, transformers or dc motors. Use to test any motor, coil or winding to determine insulation condition between windings, windings and frame, open circuits. Also measure phase balance and angle. Impedance (z) 5~1,000Ω. Inductance (L) 0.35mH~1.6H. Capacitance (C) 100mF~50nF. power factor (Fi) 0~90O. Insulation 0~20MΩ @ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz (times 2).

BJM All-Test IV PRO 2000bJM,ALL-TEST-4 AUTests single or polyphase ac motors, generators, transformers or dc motors. Use to test any motor, coil or winding to determine insulation condition between windings, windings and frame, open circuits. Measure phase balance and angle. Impedance (z) 5Ω~1kΩ. Inductance (L) 0.35mH~1.6H. Capacitance (C) 100mF~50nF. power factor (Fi) 0-90O. Insulation: 0~20MΩ @ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz (times 2).

LEM Saturn GEO Easy Earth Tester LEM,SATURN GEO EASY AUWaterproof instrument (rubber protective cover IP56). Measures earth resistance, 3 or 4 pole. Soil resistivity. Measures resistance from 0~20kΩ. Display 4 digit back light 25mm LCD. Operating frequency 128Hz. Single button user interface. Complete with earth testing kit including 4 stakes, 3 reeled cables, clips and carry case.LEM Saturn GEO X Earth/Soil Resistance Tester LEM,SATURN-GEO-x AUAutomatically tests earth/soil resistance 3, 4 pole and stakeless with CT. Optimise output frequency (manual or automatic) 0.001~300kΩ at 20 & 48Vac, frequency 94, 205, 111, & 128Hz. Displays all measuring results for as long as desired. programmable limits. Optical and audible over-limit warning. Splash-proof case Ip56 (outdoor application). Measurements with current clamps: selective, stakeless. Resistance measurements with 250mA short circuit current. Output of measured values via interface on printer or PC.LEM Saturn 100plus Safety TesterLEM,SATURN100+ AUConfirms correct operation of RCD protection, resistance of all aspects of protective earthing systems, loop impedance, line-neutral polarity, predictive short circuit current, phase sequence and voltage. RCD current 10mA~1A. Tripping time 1~500ms. Tripping current measurement with intelligent ramp. Fault voltage 0.1~99.9V. Loop and earthing resistance 0.15W~10kW. Earth electrode voltage (SEV 3569) up to 199V. Short-circuit current 1A~9.99kA. Loop/line internal resistance RLOOp 0.07~200W. Nominal line voltages 100~435V. battery-saving, automatic switch-off, typical battery service-life 3,500 insulation measurements.Multi-amp MET-2 Clamp-On Earth TesterMUL,MET-2 NZClamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2 clamp CTs without disconnecting the earth conductor. Measures dc loop resistance without any influence from other conductors.Seaward Europa Advanced Portable Appliance TesterSEW,EUROpA pAT AURecords results, compliant with AS/NZS 3760: 2001/2003 can be printed as a certificate using the serial/parallel adaptor. bar-code reader included. Earth continuity output current 100mA~25A ac. Range 0.01~20Ω. Accuracy ±5% of reading ±2 digit. Insulation test range, 100kΩ~100MΩ. Test voltage, 250, 500Vdc. Resolution 0.01MΩ. Includes plug adaptor to test, EpODs and extension leads (IEC - IEC and Australian).

inSulatiOn/cOnditiOn/reSiStance teSterS

46

ELECTRICAL POWER

Page 57: 2007 Rentalsolutionsguide-Aunz Low

Seaward PAT Management Software (WIN)SEW,pATGUARD-SW-WIN AUSeaward’s pATGuard plus takes a significant leap in electrical safety management software. Its unique “Drag and Drop” presentation makes the software intuitive and very easy to use. pATGuard both uploads and downloads appliance information and test results from the Europa xE, Europa plus and Supernova xE. Users have a complete visual overview of all appliances in terms of locations and test status. Appliances are simply dragged and dropped from one location to another. Repeat testing requirements are easily displayed allowing scheduling of tests to be conveniently managed and uploaded into the appliance testerTrolley Suitable for SEW,XE3760PKIT+ SUPERNOVA PAT TesterSEW,TROLLEY-3760pKITThis trolley is specially designed for SEW,xE3760pKIT+ and very useful for portable Appliance Tester, Seaward xE 3760 pKIT+. This trolley comes with the following accessory and contains four layer shelving, extension board with five socket 240V / 10 Amps, extension cable approximately 25 meters, 2 Nos. of elastic tie rope and a plastic bin. By using this trolley one can fit all the required instruments for portable Appliance Testing and this will improve performance and higher productivity.Seaward PAC 3760 Appliance CheckerSEW,pAC3760 AUperforms the following tests in conformance to AS/NZS 3760:2000, earth bond, insulation & polarity tests, also leakage current tests for Class I & Class II appliances and leads (leakage current testing of appliances, which requires power to “switch” them on, is the method required by AS/NZS3760: 2003). Features simple pass/fail indication. Unique 3 button operation. Class I, class II and leakage current. Automatic test sequence senses an IEC or extension lead then performs a polarity test. Detects that the appliance under test is switched “On”. Earth bond test is set at 10A and is capable of fusing a poor earth. Large LCD.

Seaward Supernova XE3760+ PAT System with Printer and ScannerSEW,xE3760pKIT+ AUSEW,xE3760pKIT NZIncludes results label/tag printer and barcode scanner. performs all AS/NZS3760: 2001/2003 compliant tests, including class 1 & class 2 leakage current 5mA/1mA, an earth conductor bond test up to 25A at 3V (approx. 100W) and 250Vdc MOV insulation resistance tests. Stores 5,000 tests in internal memory by appliance ID, including test type, detailed results, test time & date, next test due date, site & location. Calibrated resolution better than the required 5% of full scale across all ranges as specified by the Standard. Full QWERTY keyboard, and bar code reader for input. Durable plastic adhesive test label/tags printed to attach to appliances and leads includes user ID (logo optional on request) and test barcode ID, saves transcription. Compatible with Seaward pATGuard plus software package.

PRO-TAG Thermal Transfer PrinterpRO,TAG-pRINTER AUprint durable and permanent synthetic test tags on-site directly from your Europa xE, Europa plus or Supernova xE appliance safety testers. Easy - test the appliance, print the tag, peel it off and stick it on. Accountable - the pro-Tag systems are fool proof and tamper evident. Test tags are generated direct from the tester’s test results. Fast & Cheap - no more hand writing test tags and pro-Tag test tags are less than half the price of vinyl tags. Accurate - tags are printed with appliance number, appliance bar code, test date, user name and test status from the tester’s memory. Customise - you can personalise the test tag with your own company logo.

inSulatiOn/cOnditiOn/reSiStance teSterS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 47

ELEC

TRIC

AL P

OWER

Page 58: 2007 Rentalsolutionsguide-Aunz Low

pOWer analySerS & recOrderS

Model Type VoltInputs

CurrentInputs

Current (A)(Max,rms) Features Output

VOL,pM3000A

VOL,VpAS

power quality/demand

Software3 3 30 A direct

1 kA/3kA CT400 Hz, Harmonics 99th

Very high accuracyNATA certified unit available

Display, RS232,+ more

LEM,TOpAS1000 power quality/demand 4 4

3kA

Sampling 10MHzHarmonics 50th RS232,Ethernet, software

LEM,MEMObOx 300Network

performance analyser

3 4 Interharmonics 5~2,500Hz(in steps of 0.5Hz)

RS232 serial cableCODAM plus software

DRA-bMI,px5 Universal power quality/demand

4 4

3 kA/6 kASampling 1Mhz transient

Harmonics 63rdFlicker, pst, plt

128Mb, compact flashcard

DRA-bMI,px5-400 Universal power quality/demand 3 kA/6 kA

Sampling 1Mhz transient Harmonics 63rdFlicker, pst, plt

128Mb, compact flashcard

DRA-bMI,pG4400 Universal power quality/demand 3 kA/6 kA

Sample rate 256/cyclesHarmonics 63rdFlicker, pst, plt

128Mb, compact flashcard

REL,1600

power quality/demand

5 5 1 kA Sampling 4MHzHarmonics 63rd Parallel, software

HIO,3196-pQA

3 4

5 kA Sampling 2 MHzHarmonics 50th

Display, ethernet, RS232,Compact flash card

HIO,3197pQA 5 kA Harmonics 50th Display, USb

CHK,PM20 1 kA/3 kA Sampling 11.4kHz, THD Display, RS232, software

CHK,PM30 1 kA/3 kA Sampling 11.4kHz,Harmonics 48th, Ip56 Display, RS232, Software

CHK, PM30 Plus3 kA THD and individual to 48th harmonics

Flexible Cts/Clamp Cts

RS232 POWERview software,

4Mb memoryCHK,pM40pQA RS232, USb, 15Mb Memory

DRA-bMI,pR150CT

150 A Universal current clamp ac/dcDRA-bMI,pR1500 1500 A Universal current clamp ac/dc

DRA-bMI,pR6035A/36 Flexible CT 6000A ac Flexible CT, 36” lengthDRA-bMI,TR2021

CT

1-30A Instrument CT, 48Hz – 10kHzDRA,TR2510 10A ac Instrument CT, 1-10ACHK,CR100 100CHK,CR500 500

CHK,CRT1000L 1 KaCHK,CT3000L 1

CHK,CK1 3ph current converter

1CHK,CK5 5

MEG,pA9 pLUSPortable power

analyser 4 5 6 kAUp to 63rd harmonics & THD

Sample rate 256/cycleCurrent voltage simultaneously

600~6,000 flexible CTs

12Mb internal memory256Mb compact flash card

ALG,UpM6001 Power demand 3 3+aux 20 A/1 kA Harmonics 25thFor 4th current channel of UpM Display, printer, RS232,

softwareALG,UpM6100 power quality/

demand 4 4 20 A direct 3 kA Harmonics 50th, 14~500Hz

ALG,RET Flexible CT 3 kA

ALG,C173 Precision CT for earth leakage 1 mA~1 kA

48

ELECTRICAL POWER

Page 59: 2007 Rentalsolutionsguide-Aunz Low

Model Type VoltInputs

CurrentInputs

Current (A)(Max,rms) Features Output

HIO,2331-20RpMS

Power demand

4 440 0~500 A Remote power measurement EthernetHIO,2332-2RpMS

YEW,CW1403

500 A~700 A 400Hz, Harmonics 13th Display, FDD, RS232,

optional printer

AVO, pENTA-pLUS-DMM 3ph DMM/demand 3 100 direct/3 kA CT ac/dc, voltage phase angle Display, RS232,

Parallel printer

BMI,8800 Power Quality 4 4 CTs 400Hz, Harmonics 30th,Sampling 2MHz

Chart, FDD, RS232,Viewing software

bMI,A-111 Voltage plug-inbMI,A112

CT600

bMI,A116bMI,A120

3 kADRA,808 Power demand 3 3CTs Chart

DRA,TR2015 CT 3 kADRA,635-G5 Termination 5 ADRA,646-3

Power Quality4 Chart

DRA,626

DRA,pA6030-1 Graphics print out3

Chart

DRA,pA6024A Harmonics 7thMET,pF-1-F Current logger 69kV RS232, software

MET,Mx2040 1ph power demand

11CT

2 kA Display, analogue out

MET,Mx200 Clamp on Ammeter 200 A Display

LEM,ANALYST-2060 1 ph Power Demand 1 2 kA Harmonics 25th Display,RS232, IR, software

HIO,8710 Voltage/Current Recorder 3 3 1500 3 channel recorder, voltage or current Chart

DRA,CAF-RS232 Communication adaptor Fibre to RS232 with Node link software

DRA,CAF-ETHERNET Communication adaptor

Fibre to Ethernet with Node link software

DRA,128MbFMC Flashcard Ultra high speed0

DRA,DVMDS Math Driver Software Rescue kit for any corrections – logged data

pRO,MAGNUS-2.2KV Step Up Transformer 1 1Prepare excitation curves for instrument

transformer, demagnetize CT and conduct trun ratio test on VT

ACR,pOWERWATCH Disturbance Logger 1 Voltage disturbance recorderRS232

HAW,5000 Power demand 3 3 1000 Energy monitoring

pOWer analySerS & recOrderS

DRANETZ ac/dc Current Clamp 3 - 150ADRA,pR150 AUAC/dc current clamp/probe 3 - 150A RMS, max conductor size is 52mmØ. Current clamp/probe is suitable for any of new Dranetz-bMI models DRA-bMI,pG4400, DRA-bMI,px5, DRA-bMI,px5-400. Current clamp/probe is very useful for current measurement through CT current transformer. CT Ratio can be selected on the new Dranetz-bMI above-mentioned models.

Dranetz ac/dc Current Clamp 3 - 1500A RMSDRA,pR1500 AU/NZMax conductor size is 52mmØ. Current clamp is suitable for any of new Dranetz-bMI models DRA-bMI,pG4400, DRA-bMI,px5, DRA-bMI,px5-400. Current clamp/probe is very useful for current measurement through CT current transformer. CT Ratio can be selected on the new Dranetz-bMI above-mentioned models.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 49

ELEC

TRIC

AL P

OWER

Page 60: 2007 Rentalsolutionsguide-Aunz Low

Dranetz-BMI Power Xplorer PX5DRA,px5 AU/NZprovides the full range of measurements include V, I, W, VA, VAR, TpF, DpF, Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum (V, I, W) to the 63rd, Flicker (pst, plt), Crest factor, K factor, transformer de-rating etc. Min/Max/Avg values are determined in ½ cycle RMS steps. Asset comes with ac flexible current clamp DRA-bMI,RR3035A/24, current range 30/300/3,000A ac only. Can be extended to different ranges of measurement both ac & dc by selecting appropriate current clamps. High-speed transient capture (1MHz sampling rate) and the full range of arithmetic, vector and sequence parameters to evaluate distorted and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits of any active parameter can trigger logging. Voltage & current disturbances can be triggered by peak value, wave-shape change & cycle-by-cycle RMS value change. pre-event & post-event waveform capture cycles are user adjustable. Voltage & current channels can be cross-triggered. Suitable for both ac/dc power quality measurements. (Universal power Quality Analysers). DRA-bMI,px5 analysers can be used for power quality measurements, current inrush (cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage logging), long term monitoring and continuous logging at 1s intervals. Four differential voltages and current channels can be used independently. DRA-bMI,px5 is Class A compliant with IEC Standard 61000-4-30 ‘power Quality Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.

Dranetz-BMI Power Xplorer PX5-400HzDRA,px5-400 AUSpecificaion as above but with 400Hz capability suitable for aviation and military use.

Dranetz Current Clamp 1 - 30A 48Hz~10kHzDRA,TR2021 AUSet of 3 current clamps 1~30A RMS, 48Hz~10kHz. Max conductor size 0.47”. Description as for DRA,pR6035A/36 current clamps above.

Dranetz-BMI Power Guide 4400DRA,pG4400 AU/NZprovides the full range of measurements include V, I, W, VA, VAR, TpF, DpF, demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum (V, I, W) to the 63rd, flicker (pst, plt), crest factor, K factor, transformer de-rating etc. Min/max/avg values are determined in ½ cycle RMS steps. Asset comes with ac flexible current clamp DRA-bMI,RR3035A/24, current range:- 30/300/3,000A ac only. Can be extended to different ranges of measurement ac/dc by selecting appropriate current clamps. Has the full range of arithmetic, vector and sequence parameters to evaluate distorted and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits of any active parameter can trigger logging. Voltage & current disturbances can be triggered by peak value, wave-shape change & cycle-by-cycle RMS value change. pre-event & post-event waveform capture cycles are user adjustable. Voltage & current channels can be cross-triggered. Suitable for both ac/dc power quality measurements.(Universal power Quality Analysers). DRA-bMI,pG4400 analysers can be used for power quality measurements, current inrush (cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage logging), long term monitoring and continuous logging at 1s intervals. Four differential voltages and current channels can also be used independently. DRA-bMI,pG4400 is Class A compliant with IEC Standard 61000-4-30 ‘power Quality Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.

Dranetz Flexible Current Clamp 60/600/6,000ADRA,pR6035A/36 AUSet of 3 flexible current clamps 60/600/6,000A RMS, max conductor size/length of clamp is 36”. Current clamps are suitable for any of new Dranetz-bMI Models. DRA-bMI,pG4400 / DRA-bMI,px5 / DRA-bMI,px5-400. Current clamp/probe is very useful for current measurement through CT current transformer. CT Ratio can be selected on the new Dranetz-bMI above-mentioned models.

Dranetz Current Clamp Probe 0~10A RMSDRA-bMI,TR2510 AUSet of 3 current clamps 0~10A RMS. Max conductor size 0.47”. Description as for DRA,pR6035A/36 current clamps above.Dranetz-BMI, 128 MB Flash Memory Card (Industrial Grade)DRA,128MbFMC AU/NZSuitable for the following Dranetz -bMI Models:- DRA-bMI,px5, DRA-bMI,px5-400, DRA-bMI,pG4400.

pOWer analySerS & recOrderS

50

ELECTRICAL POWER

Page 61: 2007 Rentalsolutionsguide-Aunz Low

Dranetz Communications Adapter - Fibre to Ethernet with Node Link SWDRA-bMI,CAF-ETHERNET AUCommunications Adapter - Fibre to Ethernet with NodeLink Software and Moxa Networking Software for the following Dranetz-bMI Models:- DRA-bMI,px5, DRA-bMI,px5-400, DRA-bMI,pG4400.

Dranetz View Math Driver Software (Add ON)DRA-bMI,DVMDS AUIn 4 essential areas, the Math package will improve measurements:-Rescue Kit. Ever hooked up a probe the wrong way? May be forgotten to check if the actual time in your instrument is running correctly? Or could you have possibly forgotten to set the correct K-factors? The Math -package helps you to correct these errors, re-calculate parameters from available waveform data, invert waveforms and much more. Improve Measurements / Reports. Calculate additional parameters for your Multi-DAQ TASK Card, fault-recorder/inrush mode measurements, with the math driver the following additional trends will be created for Multi-DAQ data files: V rms, Watts, VAR’s, VA, True pF, V thd (%fundamental), I thd (abs current) Voltage Frequency (for internal trigg) and Net Totals V rms, Amps, W, VAR & VA. Generate More parameters from waveform data. Showing Displacement power Factor (DpF) instead of K-factor. Rename inputs. Energy ON/OFF peak calculations. Mathematical expressions and formulas can be used to plot additional user-defined channels within both the time-plot chart and the waveform chart. Advance analysis, watt harmonics, symmetrical components, etc.Dranetz 646-3 Disturbance RecorderDRA,646-3 AUAccepts up to 3 ac line inputs 50~600V, 1 neutral to ground input 5~200V, & 1 dc voltage input 1~100V. Monitors and records impulses, sags, surges, under and over voltages and frequency variations on 1~3ph ac, 47~63Hz. Impulse duration 1~1,000µs.Dranetz 626 Power Disturbance MonitorDRA,626 AUFor use with up to 5 x pA series plug-ins. Monitors sags, surges, impulses and changes in frequency.ACR Voltage Disturbance LoggerACR,pOWERWATCH NZSingle phase 230V disturbance logger. Plugs into a standard 230V 3pin power point. Stores up to 4000 events such as sags, surges, outages, impulses & frequency variations. Supplied with software & serial cable for programing, uploading and printing results.BMI 8800 Power Disturbance AnalyserbMI,8800 AUEight inputs giving simultaneous voltage and current (optional probes required) monitoring of up to 4 channels each. FDD included. Each disc stores 600 disturbances for transfer to the internal graphics printer. Harmonics measurement option included for up to the 40th harmonic of 50Hz. Max input voltage 600V rms or dc. Eight extra channels included for sensor outputs, etc. Operates from ac mains or 11~16Vdc. In-built UpS.BMI A-111 ac/dc Voltage Impulse ProbebMI,A-111 AUFor bMI,4800/8800. Uses probe channels to increase the number of voltage inputs that can be monitored. Ranges 0~600V rms, 0~100V dc. Impulses 0V~2.4kV peak.BMI A112 Current Probe for BMI 8800bMI,A112 AUFor bMI,4800/8800. Measures current waveforms to 600A and allows graphic representation on bMI,4800 printout. Jaw opening 50mm. True rms measurements for motor startup, current surges, etc. Range can be extended to 3kA by using DRA,TR2015 in secondary loop configuration.

BMI A116 600 Amp Clamp-on Probe for 8800bMI,A116 AUAperture 50mmØ. bandwidth 3kHz.BMI A120 3000 A Clamp-on Probe for 8800bMI,A120 AUAperture 63 x 160mm. bandwidth 3kHz.Metrosonics PF-1-F Overhead ProfilerMET,pF-1-F AUDistribution line profilers for current measurement on power lines. Logs current consumption to internal memory. Set of 3 profilers with one display module. Windows software included. Current range 5~1000A. Resolution 1A. Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate 1s~10min. Memory 64k readings. Data storage modes: stop when full or wrap around. Data retention after low battery shutdown 30d. Min conductor spacing 600mm.

>NEW Hioki Remote Power Measurement System 2331-20 RPMS SmartSite

HIO,2331-20RpMS AUFor multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3 wire & 3ph 3 wire up to 3 circuits. Provides via a PC, management of measurement data to support energy and environmental management. Modulated measurement units take advantage of a variety of infrastructure to collect measurement data. Use as a stand alone logger and for remote monitoring. Use as a pC measurement logger keeps measuring and continuously saves the data. Measurement modules comes with memory and clock. build a customised and remote measuring system by utilizing existing data network. Modules for temperature, humidity, instrumentation and pulse, power module for multiple circuits. Large internal memory. Communication module with built-in real-time clock tracks the data of each measurement module to the second. Air Module for constructing SS wireless systems.

>NEW Hioki Remote Power Measurement System 2332-20 RPMS SmartSite

HIO,2332-20RpMS AUDescription as for HIO,2331-20RpMS above.Hawk 5000 3 Phase Power Demand LoggerHAW,5000 NZThree phase wye power demand logger. Records kVA, kW, V, I, Freq & pF. Uploads data to a pC for graphing and printing. Supplied with software and 3 x 1kA clamps.Dranetz 808 Power Demand AnalyserDRA,808 AUDisplays and prints on in-built printer - V, A, pF, kW, kWh, kV/A, kVAR, demand, time and date for single and three phase systems. For use with DRA,635-G5 terminations or TR series clamp-on current transformers.Dranetz TR2015 Clamp-on Current TransformerDRA,TR2015 AU/NZFor DRA,808. Ranges 1, 2 & 3kA. Requires DRA,635-G5 termination.

pOWer analySerS & recOrderS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 51

ELEC

TRIC

AL P

OWER

Page 62: 2007 Rentalsolutionsguide-Aunz Low
Page 63: 2007 Rentalsolutionsguide-Aunz Low

pOWer analySerS & recOrderSVoltech PM3000A 3 Phase Power AnalyserVOL,pM3000A AUCapable of making measurements of all standard electrical characteristics of 1 & 3 phase supplies. Measures inrush current and crest factor, load impedance and harmonic analysis, energy and max demand, extendable using current and potential transformers. Frequency range dc~500kHz. parameters W, VA, Var, V, A, pF, peak voltage and current, crest factor, impedance, peak inrush current, voltage and current harmonics, 99th order, THD, Hz, Wh, VAh, Varh, Amph, average pf. Input coupling may be ac or ac + dc. Outputs printer, recorders (8), and oscilloscopes. IEEE, RS232C, and centronics interfaces and waveform output derived from current and voltage inputs are included. Accuracy V & A 0.05%, power 0.1%. Input ranges voltage 0.5V~1kV rms, current 0.05~30A rms (200A peak). Accessories 3 x 1kA clamp-on CTs, and 3 x precision 100A/1kA dual range current transformers 0.2% (not clamp on).Voltech PM3000A with NATA CalibrationVOL,pM3000A-NATA AUSpecifications as above but with NATA calibration.LEM Analyst 2060 Hand-held 1 Phase Clamp-on Power Meter AnalyserLEM,ANALYST-2060 AUMeasure, record and log W, VA, VAR, kWh, and power factor. Current to 2kA auto-ranging ac or dc. peak, Crest Factor, THD, DF and frequency for voltage (4~750V) and current. Harmonics to the 25th order. Time base is selectable from 2ms/div~50ms/div. Large backlit multi parameter display, with oscilloscope and chart modes. Memory size: 8 screens smart save and up to 10,000 readings. Jaw opening capacity 60mmØ. Typical battery (6 x AA alkaline) life 24h without backlight.LEM Topas 1000 Power Network AnalyserLEM,TOpAS1000 AUMeasures all relevant parameters in one measurement system. Inputs (isolated) voltage 4 channels, 200mV~1kV, current 4 channels, supplied with 4 x 0~10A, 10~100A ac clamp-on CTs and 4 x (unit powered) 0~3kA LEM-Flex current sensors. Can be configured for 8 voltage channels. Measuring functions rms, V(U) voltage imbalance, positive, negative & zero phase sequence, phasor (vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz), energy, on-line oscilloscope, power and multimeter, harmonics (by power/direction, magnitude & phase), inter-harmonics, THD, flicker, transients (100kHz~10MHz), will capture events from 0.1µs in duration. Software configured manual or auto trigger levels, ethernet or serial interface, memory >540Mb/HDD.

LEM Memobox 300 Network Performance AnalyserLEM,MEMObOx300 AUWeatherproof (Ip65)3ph power analyzer. High accuracy to Class A IEC 61000-4-30. Suitable for 50Hz or 60Hz systems. LEMflex flexible current probes with ranges 15, 150, 1,500 & 3,000A suitable for conductors up to 178mmØ. Voltage ranges from 115~830V on 3 or 4-wire systems. Measures V, A, kW, kVA, kVAR, kWHr, pF, Hz, crest factor, distortion power, THD, individual harmonics of volts & current up to 50th harmonic, flicker and ripple control signal levels. Power measurements by either 2 or 3 wattmeter method. power supply 88~415V either from measurement leads or separate supply. Memory size 4Mb with 5,700 sampling intervals. Sampling intervals selectable from 1s~60min. Sample interval of 5min records for >19Days. Linear or circular (overwrites earliest data once full) memory. Records average, 10ms min & 10ms max in each interval. Captures motor start current spikes with corresponding voltage-dips. Captures up to 13,000 voltage sag/surge events 10ms or longer. Weight 1.1kg.

LEM Elmes 693 3Ph Power LoggerLEM,603 NZLogs, voltage, current & pF. True RMS: VA, VAr, pF, Volts, A & frequency. Sampling rate is 1s. Statistical measurement interval can be set from 1~60min. Supplied with flexible 1kA Rodowski CTs, 5A clip-on CTs and software for programming and uploading results. Accuracy, active power ±2%, reactive power ±3%, phase angle ±3%, voltage ±1.5%.Reliable Power Systems 1600 AnalyserREL,1600 AUPower analyser for parameter, demand, and disturbance measurement and long term monitoring. pC required for download - no onboard display. Complete with 1kA CT’s & 5A CT’s. V & I sampled at 8kHz, min/max values have 1 cycle response. Impulses sampled at 2 & 4MHz software selectable. Max input voltage 700V rms. Notebook pC with Win 95 and Office 97 included. Algodue UPM6001 Power/Demand AnalyserALG,UpM6001 AUIncludes 3 x 1kA clip-on current transformers. Integral digital display and printer. Memory 512kb plus RS232 interface for data transfer. Measures each phase & total V, A, power, pF, VA, VAR. Measures demand over a defined interval, harmonic distortion, and provides FFT analysis. Records maxima and minima. Current inputs are at 1V or 5A for external CT’s. Voltage drop detection for durations exceeding 150ms. Software provides time plots and remote display of measurement parameters. Higher speed FFT harmonic plot possible up to 25th harmonic.Algodue UPM6100 Uni Power Meter 500Hz & Rogowsky 3kA OptionsALG,UpM6100 AUpower meter 3kA Rogowski current transducer (flexible CTs), 14~500Hz, harmonic distortion current and voltage 50th order. Large 4Mb memory.Algodue Ret Set of 3 Rogowski TransducerALG,RETUse with the ALG,UpM6001. Ranges 300A/3kA. powered from analyser.

>NEW Hioki 3197 Power Quality Analyser with 3x1000A Clamp-on CTs

HIO,3197pQA AUMonitors inrush current, voltage swell, voltage dips, transient over-voltage and interruptions. Measure and records power and power factor, active/reactive energy, demand, load changes (with graph display), voltage and current. Measures impulsive voltage quality. RMS voltage quality, voltage swell, voltage dips & voltage interruption. Power quality, frequency, voltage, current, current peak, active/reactive/apparent power & power factor (displaced power factor). Three phase quality, voltage unbalance ratio, current unbalance ratio, harmonic quality (up to 50th order). Harmonic, voltage, current, ower, voltage/current phase angle. Total harmonic, voltage distortion, current distortion (THD-F, THD-R).

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 53

ELEC

TRIC

AL P

OWER

Page 64: 2007 Rentalsolutionsguide-Aunz Low

>NEW Hioki 3169-20 Clamp-On Power HiTester for Power Measurements

HIO,3169-20CLAMpONpT AUAllows measurement of 1ph~3ph 4-wire circuits with a single unit. In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, this unit can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. Features PC card data storage and comes equipped with an RS232C interface for PC communications. Can measure the power of just a few cycles, enabling more detailed and effective energy-saving measures. Supplied with Hioki 9625 power measurement support software for data analysis. Measure up to 3ph, 3 wire system (displays voltage and current for 3 lines), up to 4 x 1ph, 2 wire systems, 5A~5kA range, pC card data storage, power recording for individual waveforms. Simultaneous recording of demand values and harmonics. Applications are energy maintenance/control, energy control under ISO 14000, saving energy activities, power consumption measurement of specific device/equipment, harmonic analysis.

>NEW HIOKI 3169-21 Clamp-On Power HiTester

HIO,3169-21 CLAMpONpT AUMeasure up to 3-phase, 3-wire system (displays voltage and current for three lines), Measure up to four single-phase, 2-wire systems, 5A~5000A range. Compact and light weight, PC card data storage, power recording for individual waveforms, simultaneous recording of demand values and harmonics. Main applications: energy maintenance/control, energy Control Under ISO 14000, saving energy activities, power consumption Measurement of specific device/equipment and harmonic analysis. Complete with RS232C interface for pC communications. Supplied with Hioki 9625 powerMeasurement Support Software for data analysis.Hioki 3196 3 Phase Power Quality AnalyserHIO,3196-pQA AUHigh speed (0.5µs 2MHz) field unit. Channels 4 voltage, 150~600V rms 4 ranges (isolated), 4 current 0~5kA (3ph and neutral) rms 2 ranges. Supplied with 4 x 5kA flexible clamp-on CTs (length 945mm). Memory 13Mb internal, 512Mb compact flash card. Display internal high resolution colour LCD. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 50th order) flicker IEC6100-4-15. Total energy, tariffs, max demands, transient and sub-cycle disturbances. Software provides graphs and summaries to PC. Interfaces RS232 and 10base ethernet.

>NEW Hioki 9670 Thermal Printing Method Printer, Input RS232C

HIO,9670 pRINTER AUUses stationary type, thermal printing method printer which prints date input via RS232C from a computer or the other host system. Convenient battery that makes easy to carry around. provides high-speed printing with very little noise. provides clear printing of 16 x 16 dots and 24 x 24 dots (as well as Japanese characters JIS Level I and II), and can print bar codes. provides various settings such as enlarged-character printing. Graphics can be printed using bit images.

Hioki 9694 Clamp-on CT 5AHIO,9694CT5A AURated primary current 5A ac. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at 45~66Hz), 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated wire. Core jaw 15mmØ. Size: 46w × 21d × 135hmm, cord length 3m.Hioki Clamp-on 100A ac CTHIO,9660CT100A AURated primary current 100A ac. Amplitude accuracy: ±0.5% rdg. ±0.2%fs (at 45~66Hz). 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.Fluke 43 Power Quality AnalyserFLU,43 NZSingle phase power quality analyzer. Combination power quality analyzer, multimeter and scope. Scope displays voltage and current waveforms. Measures true-rms voltage, current and frequency. Measures voltage, current, and power harmonics up to 51st harmonic. Total harmonic distortion (THD). Phase angle of individual harmonics. Continuously measure volts and amps on a cycle-by-cycle basis for up to 24h. Use cursors to read time and date of sags and swells. Supplied with 500A current probe, software and cable.Fluke 43B 1 Phase Power Quality AnalyserFLU,43b NZCombines the capabilities of a power quality analyser, scope and multimeter in a single easy-to-use instrument. EN 61010-1 CAT II, 600V. UL and CSA listed. Recording times 4min~16d (selectable).Megger PA9Plus Portable Power Quality & Demand AnalyserMEG,pA9pLUS AUIntegral graphic backlit LCD and compact flash card memory. Measures and records all voltage/current power and waveform activity. Input voltage, 4 differential channels auto ranging between 20~300, 300~600V ac, V dc scales, accuracy ±0.25% of reading, ±0.05% of range to the 63rd harmonic. Crest factor voltage 3.5 limited to 1.5kV peak. Current 1.4 of full scale at peak input. Current 5 channels resolution 0.1% fs, accuracy ±0.25% of reading, ±0.05% of range to the 63rd harmonic. Frequency fundamental 50Hz response dc to 3.15kHz (63rd harmonic). Resolution 0.01Hz. Sample rate 256/cycle current and voltage simultaneously. Harmonic distortion current and voltage to the 63rd order and THD. power supply 90~600Vac, 50Hz, 100~600Vdc either via channel 1 or from independent IEC lead. Memory 12Mb internal, 512Mb compact flash card. Current sensors 4 x 600~6,000A Rogowski flexible. Report generation software included. Set-up and download can be done through RS232 or flash card.

>NEW CCI Power-Mate 15A Single Phase Power/Energy Measurements

CCI,pOWER-MATE 15A AUCan accurately measure and calculate power, volts, amps and energy being used by an electrical appliance. Also measures the greenhouse gas emission created by an appliance. Can determine the actual running cost, how much energy the appliance used in kilowatt-hours and how many kilograms of greenhouse gas emissions it produced all in hourly, yearly, quarterly and accumulated figures. Features an LED display for easy reading and high visibility at all times. 15-amp version - to a maximum continuous capacity of 15A, but readings are accurate to 18A and the cable is rated to 15A. provides a variety of measurements including: power in watts, voltage and current. Provides the minimum, maximum as well as instantaneous readings.

pOWer analySerS & recOrderS

54

ELECTRICAL POWER

Page 65: 2007 Rentalsolutionsguide-Aunz Low

>NEW CHK Gridsense PM40 Power Quality Analyser

CHK,pM40pQA Weatherproof Ip65 field unit. Channels: 3V, 63-440V (isolated). 4 current 0 to 3,000A (3ph and neutral) rms. Supplied with 4 flexible 3,000A clamp-on CTs (flexible CT length 600mm and Diameter 190mm). (In addition, clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A for neutral conductor current measurement are available.) Memory: 15 Mb. Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current imbalance (THD and individual to 48th ) and Flicker. Total energy, tariffs, maximum demands, and transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Download files while logging USb interface. A pC using Windows 95, 98, NT4, WIN2000 or xp O/S, is required with the CHK powerView software to configure this unit before operating.

GridSense CHK PM30 Plus 3 Phase Powermonic Logger/LoggerCHK,pM30pLUS AUWeatherproof Ip65 field unit. Channels 3 voltage, 63-440V (isolated), 4 current 0 to 3kA (3ph & neutral) rms. Supplied with 3 x flexible 3kA clamp-on CTs (flexible CT length 600mm & 190mmØ). Clamp-on CTs of 3kA, 1kA for large conductors and 500A & 100A for neutral conductor current measurement are available. Memory 4 Mb. Inbuilt 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 48th ). Total energy, tariffs, maximum demands, transient and sub-cycle disturbances. Software provides graphs and summaries to PC. Download files while logging via RS232 interface. pC using Win 95, 98, NT4, 2000, xp, O/S, is required with the CHK pOWERview software to configure this unit before operating.

pOWer analySerS & recOrderS

the latest addition to the rugged, weatherproof and versatile powermonic range has features including:

• flickermonitoring• interharmonics• voltageunbalance• increasedmemorycapacity(15mb)• largerlcddisplay• real-timedatadisplay• compliancetoalliEcpqstandards• high-speedusbdatatransfer

for more information visit - http://www.gridsense.net

Other features include:

• tables&graphsof3phasev,a,pf,dpf,kw,kva,kvar,thd,harmonicphaseangle,individualharmonics,interharmonics,frequency,alltoiEcstandards

• totalEnergy&tariffscalculator• abilitytocapturemotorstarts,highspeedrms&waveform

disturbances

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 55

ELEC

TRIC

AL P

OWER

Page 66: 2007 Rentalsolutionsguide-Aunz Low

CHK PM30 3 Phase Powermonic Power LoggerCHK,pM30 AU/NZWeatherproof Ip65 field unit. Channels 3 voltage, 63~440V (isolated), 4 current 0~3kA (3ph & neutral) rms. Supplied with 3 x 1kA clamp-on CTs (cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors and 500A & 100A for neutral conductor current measurement are available. Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 48th ). Total energy, tariffs, max demands, transient and sub-cycle disturbances. Software provides graphs and summaries to PC. Download files while logging via RS232 interface. pC using Win 95, 98, NT4, 2000, xp, O/S, is required with the CHK POWERview software to configure this unit before operating.CHK PM20 Power Quality Analyser/LoggerCHK,pM20 AUThree phase, weatherproof Ip65 field unit. Three voltage channels 63~440V (isolated). Four current channels 0~3kA rms (3ph & neutral). Supplied with 3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and 500A for neutrals clamp-on CTs are available. Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and tariffs, high speed rms waveform capture events outside preset limits (10ms intervals). Software provides graphs and summaries to PC. Download files while logging. RS232 interface. pC using Win 95, 98 or NT4 O/S, is required with the CHK POWERview software to configure this unit before operating.CHK 3 Phase Converter for CTs 1A Input to 200mA OutputCHK,CK1 AUAdaptor for CTs with 1A secondary outputs, this unit suits CHK,pM30/20.External Modem 56k Remote Communication for CHK,PM30/PQACHK,MODEM-56K AUExternal modem 56k for CHK pM20, CHK pM30, CHK pM30pLUS or any other power quality analyzer. Modem gives remote access control to set-up/download any connected Instrument.CHK 3 Phase Converter for CTs 5A Input to 200mA OutputCHK,CK5 AUAdaptor for CTs with 5A secondary outputs, unit suits CHK,pM30/20.CHK CR100 Clamp-on CTCHK,CR100 AUJaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to measure neutral current. Accuracy Class 1.CHK CR500 Clamp-on 500 CTCHK,CR500 AUJaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to measure neutral current. Accuracy Class 1.CHK CT1000L Large 1kA Primary Clamp-on CTCHK,CT1000L AULarge 123 x 35mm 1kA primary clamp-on CT for CHK,pM20/30.Gridsense 3000 Amps Flex CT 600 mmCHK,CT3000 pLUS AU

CHK CT3000L Large 3kA Primary Clamp-on CTCHK,CT3000L AULarge 123 x 35mm 3kA primary clamp-on CT for CHK,pM20/30.Metrix MX200 ac/dc Clip-on Power MeterMET,Mx200 AU/MYRanges 19.99 & 199.9A. Measures voltage to 750V, frequency to 999Hz, power 1.99 & 19.99kW, apparent power 1.99 & 19.99kVA, & pf. Recorder output via special leads (supplied) for current range only, 5mV/A on 199.9A range. Switch in battery compartment gives ac as well as dc output. Internal battery for 70h operation. Clamp capacity 23mmØ or 20 x 10mm bars.Metrix MX2040 ac/dc Clamp-on MeterMET,Mx2040 AU/NZMeasures A, V, Hz, kW, kVA, kVAR, kWH, pF and resistance. Ranges 200A & 2kA, 600V & 1kV, 20, 200kW & 2MW & kWH. Scale length 3,000. 1 & 3ph operation. Motor rotation indication. peak, min, max, average, rms, and crest factor indication. peak response time 1µs. Analogue output option fitted giving dynamic signals and calculated parameters (energy, etc).

Martindale Phase Sequence & Continuity Indicator 100~600V, 50/60HzMAR,pSCI424-585 AUTester may be used, on 3ph circuits, to check the presence & sequence of the phases. Important on motor circuits as a phase reversal will cause a motors direction to reverse. Tester will give visual indication of loss of phase or an incorrect sequence. Tester is supplied in 2 forms - probe style, the connection to the tester is via 3 insulated cables to 3 fused test probes, 1 with an insulated crocodile clip. plug style, a 16A, 4 pin, 3ph & earth, bS4343 plug is fitted to the tester. Use as a socket tester prior to plugging in 3ph equipment. Testers supplied in a plastic wallet, with full instructions. Caution, the unit should be checked for correct operation using a known voltage before use.

Yokogawa CW140 Demand/Harmonics AnalyserYEW,CW140 AU/NZIncludes 4 x 500A clip on current transformers, jaws 30mmØ inside. Current transformers are accurate at currents of <1A. For current applications in excess of 500A use DRA,TR2015 & TR,CT-5. Has wiring check maps, power, VAR, Hz, VA, pF. Works at frequencies from 45Hz~1kHz. Harmonics to 13th order. Electric energy mode to measure Wh, Varh. Monitor and compare 2 separate loads. Event and external trigger inputs and D/A outputs. portable battery powered with large LCD screen and soft keys for operation. Supplied with Rion Cp-10 printer.

Programma Magnus 2.2kV Step Up Transformer for Testing CT’spRO,MAGNUS-2.2KV AUUse in high-voltage substations and industrial environments. protected with thermal cut-outs, mains voltage 230Vac ±10%, 50~60 Hz, power consumption is 2.3kVA. Used for preparing excitation curves for instrument transformers and for demagnetizing current transformer cores quickly and easily. Also used to conduct turn-ratio tests on voltage transformers. provides 1A at 2.2kV output. Two-hand control enhances personal safety. Weighs 16kg. Supplied with a special high-voltage cable and robust transport case.

pOWer analySerS & recOrderS

56

ELECTRICAL POWER

Page 67: 2007 Rentalsolutionsguide-Aunz Low

>NEW Omicron CPC 100 PTS for CTs/VTs/Power Transformer

OMI,CpC100pTS AUAllows for automated testing of power transformers, CTs, VTs, resistance testing, and more. providing up to 800A (or 2000A with current booster) and 2000V and comes complete with an integrated PC. Its software routines test a wide range of substation equipment, and automatically creates customizable reports. Weight: 29 kg. Analog voltages and currents can be measured with very high precision. Its Ohm meters automatically switch ranges from µOhm to kOhm to allow for a wide variety of applications. Testing of unconventional equipment, such as Rogowski Coils or current sensors completes the spectrum. Safety features: emergency shut off button, safety key lock (block unauthorised use).

Omicron CMC156-3 Advanced Protection Relay Test SetOMI,CMC156-3 AUFor three-phase testing of relays, meters and transducers, for applications requiring portability. • 3 x 125V outputs, • 3 x 12.5A outputs, • 6 x low level outputs (rear side), • 2 x counter inputs (rear side), • 4 x binary outputs, • dc measuring inputs, • 10 x binary inputs. Applications are digital distance relay testing or testing of transformer operated energy. Signal generation is performed digitally. The 16-bit D/A conversion results in a high quality signal event at small signal amplitudes. In addition to the 6 outputs of the amplifier section, 6 independent channels with low-level signals are available at the back of the unit which can be used to control external amplifiers for applications requiring more than 3 voltage or current phases, e.g., testing of differential relays, or applications requiring higher currents or voltages. They are also useful where there is a need for output power higher than that provided by the CMC 156. Comes with Test Universe 2.01 software loaded on dedicated laptop. Weighs 9.8 kg.

Omicron CMC256-6 EP Advanced 3Ph Protection Relay Test SystemOMI,CMC256-6 Ep AUCurrent integral 3ph current source max 140VA, 6 output sources, resolution 500µA, suitable for most relay types, including some high burden units. Voltage 3 ph voltage 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay monitoring trip, monitoring 6 isolated inputs, can be configured to be voltage free or 0~250V. Contact outputs 6 isolated change-over relay contacts (software controlled). Max 250V ac 10A or 125V dc 1A. Interface connector, 16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated analogue inputs ±500V peak max 12 bit resolution. Input supply 90~260V dc, 400Hz. Intuitive on-line help. Notebook 486 or better Win 3.11, 95, 98 or NT, display SVGA or better. Interface parallel port.

Omicron CMGPS Syncronisation Control UnitOMI,CMGpS AUGpS-based synchronisation unit, which is used to synchronise CMC (protection Relay) test sets. Used when performing end-to-end tests of line protection schemes, the unit provides a start signal pulse based on the GpS clock time base. Software is both integrated in the testing modules (State Sequencer) and can also be used as a stand-alone application. Two independent timing pulses are available via separate connectors, on a 16-pin plug (pulse out 1) which is connected with the CMC test set (external interface) and on 2 x 4mm banana plugs (pulse out 2). Supplied with GpS antenna, 15m antenna ext cable, plug-in power supply, CMC-CMGpS interface cable, users manual, fabric carry bag and a travel case. Weighs 5kgs.Omicron C-Probe-1 Clamp-on CT ac/dcOMI,C-pRObE1 AUAn active ac & dc current probe with voltage output. Recommended accessory for measuring currents with the CMC 256. Two measuring ranges: 10A & 80A. Frequency range dc 10kHz. Accuracy error < 2% for currents up to 40A and frequencies up to 1kHz. phase error < 0.5O @ 50/60Hz. Length 230mm.Omicron CMC256-6 Advanced Protection Relay Test SetOMI,CMC256-6 AUAdvanced 3ph dynamic automatic protection relay test system. Current, integral 3ph current source max 140VA, 6 output sources, resolution 500µA, suitable for most relay types, including some high burden units. Voltage, 3ph 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay monitoring trip, monitoring 6 isolated inputs, can be configured to be voltage free or 0~250V. Contact outputs 6 isolated change-over relay contacts (software controlled). Max 250Vac, 10A or 125Vdc 1A. Interface connector, 16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated analogue inputs ±500V peak max 12 bit resolution. Input supply 90~260Vdc, 400Hz. Intuitive on-line help. Laptop and Test-Universe software up to TU V 2.01 supplied with test set, interface parallel port.

Programma Sverker 760 Relay Test SetpRO,SVERKER760 AURelay test set for 1ph protective relay equipment. Three phase relays can be tested 1 phase at a time or by synchronising more than one unit. Current ranges to 100A with full load current to 250A. AC outputs to 250V & dc outputs to 300V. In-built capacitor and resistors for current output phase shifting (3600). In-built timer, ammeter, and voltmeter. Measures phase angle, PF, and impedance. RS232 communications and control interface.

prOtectiOn relay teSting SyStemS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 57

ELEC

TRIC

AL P

OWER

Page 68: 2007 Rentalsolutionsguide-Aunz Low

prOtectiOn relay teSting SyStemST&R DVS3-HP Static Relay Test SystemT&R,DVS3-Hp AUTest system for testing voltage and frequency protection relays and transducers. Tests Automatic Voltage Regulating (AVR) relays with line drop compensation, under and over voltage relays, directional over~current relays, df/dt (ROCOF) relays, vector surge (step change of phase) relays and check synchronising relay. Generates a 3ph voltage output from a 1ph supply, and may be used in conjunction with a current source to test directional protection. Requires 1ph 50/60Hz supply of 115V or 230V (±15%). Unit automatically selects the correct range. Max power requirement of the unit is 0.5kVA. DVS3-Hp has 3ph star connected output and the rating of each phase is:- voltage 0~133V phase to neutral, current 5min on/15min off 330mA @ 133V, or 200mA continuous, phase lock 45Hz~65Hz., variable frequency 40~999.9Hz., variable phase angle ±180O. Delta loads may be connected directly to the output or through the DVS-T VT box. Max voltage obtainable is 133V between any phase & neutral and 266V between 2 phases (if the phase angles of the 2 phases are set to 180O apart). DVS-T VT box may be used to double these output voltage (Ratio 1:2).

>NEW Programma EGIL Circuit Breaker Analyser

pRO,EGIL-Cb ANALYZER AUOne main contact per phase. Three time channels are connected together on one side. Events at parallel contacts equipped with pre-insertion resistors are recorded and displayed simultaneously. Two separate time channels for measurement of auxiliary contacts. On-site hookup comes with ready-made multi-cable sets for both main and auxiliary contacts. Coil currents are measured automatically, presented together with other readings immediately after testing on the display window or via the built-in printer. A built-in sequencer (program unit) sets the instrument automatically for the next sequential breaker operation. Intended primarily for measuring travel (motion). Can be equipped with an optional serial interface (RS232C) for communication with a pC and the CAbA Win breaker Analysis Software.

©2006 Fluke Corporation. All rights reserved. Ad 01981

Get more done.

More tools for commercial and plant technicians.Get the job done faster and more accurately with Fluke’s innovative set of tools for electrical test. From IR thermometers to clamp meters, every rugged tool delivers the reliabilty, accuracy and safety you expect from Fluke.

Power Quality compliant load studies, energy consumption testing and general power quality logging.Verify your power. The Fluke 1735 Power Logger is the ideal technician’s tool for conducting30-day load studies. • Set up in seconds• Measure all 3 phases and neutral• Log most electrical parameters, plus harmonics and voltage events

More information and resources.You can always count on Fluke for the troubleshooting techniques, application information, and training to keep your electrical systems up and running.

Fluke Australia Pty Ltd. Phone: (02) 8850 3333 Fax: (02) 8850 3300

Email: [email protected]

Power QualityAnalysers

Earth GroundTesters

Insulation Testers Thermal Images

Fluke. Keeping your worldup and running.

58

ELECTRICAL POWER

Page 69: 2007 Rentalsolutionsguide-Aunz Low

High Voltage Test Set 30kV/50 Hz AC Hi Pot TesterHIV,pFT303 AURated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA 1/2 hours on 2 hours off, at 2 kVA 1 hour on 1 hour off. For a field and repair shop HV testing applications. Tests the integrity of items including insulating materials, isophase bus duct, switchgears, transformers, vacuum bottles & interrupters, vacuum switches, automatic circuit reclosers, bushings, fuses, arrestors, circuit breakers, transformers, capacitors, motor and generator windings.

High Voltage PFT503, 50kV ac Test SetHIV,pFT503 AURated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA ½h on 2h off, at 2kVA 1h on 1h off.High Voltage Inc Very Low Frequency (VLF) 6022 60 kV Hi-pot Test SetHIV,VLF6022 AUFor field testing of ac high/medium voltage cables, bushings, and insulators. Input 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0~60kV ac peak, frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance 1.1µF (approx 3kms of cable at 0.1Hz), 2.2µF (approx 9 of cable at 0.05Hz) & 5.5µF (approx 13kms of cable at 0.02Hz). Display 0~60 peak kV. Interconnect cable length 3m, control unit to HV transformer. RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control units shipped in travel cases weighing 70 & 40 kgs respectively.

Baur PGK80 High Voltage (80kVDC) Insulation TesterbAU,pGK80 AUMax output 80kV at 0.8mA. In-built timer, zero start interlock and automatic discharge device.Megger FT6/12 Ionisation, Leakage and Breakdown TesterMEG,FT6/12 AU/MYAC ranges 0~2kV, 0~6kV, dc ranges 0~4kV, 0~12kV. Output currents 7.4mA, 8.9mA ac & 2.1mA, 2.5mA dc. breakdown and flashover indication by latching indicator for periods exceeding 1ms. Current threshold 100µA~1mA. Ionisation indication by internal speaker. Meter indication of ac, dc and ac capacitive currents. Complete with probes.

T&R kV30-40, 30kV ac Hipot Test SetT&R,KV30-40 AU0~30kV, max output 40mA with a duty cycle of 5min on & 15min off. Max continuous current 20mA. Overload trip may be set from 4~44mA. Zero interlock and key operated safety features.

High Voltage Test Set VLF 90 KvHIV,VLF90 AUVery low frequency (VLF - 90 CM) ac hipot test set with 90kVac peak output, is suitable for testing cables up to 50kV. High load capacity enables it to test up to approx 7 miles of cable, depending on type. Model includes a charging current and load capacitance meter, test dwell timer, and polarity indicating lights. Output voltage & frequency,- sinusoidal 0~90kVac peak & selectable, 0.1, 0.05,0.02Hz. Test frequency and rated loads with approximate cable lengths are:- 0.1Hz/0.55µF 1,673m of cable, 0.05Hz/1.1µF 3,353m of cable, 0.02Hz/2.2µF 6,706m of cable. Kilovoltmeter scaled 0~100kVac peak, ammeter scaled 0~100mAac & 0~6µF load capacitance. Weight of the unit 167kgs. HV Cable output is 6m flexible, shielded x-ray with alligator clamp, inter connect cable length 3m, shorting stick 6m lead with clip.

High Voltage Inc VLF 4022 40kV Hi-pot Test SetHIV,VLF4022 AUFor field testing of ac medium voltage cables, bushings, and insulators. Consists of control unit and HV tank. Input: 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0~40kVac peak, frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance 1.1µF (approx 3kms of cable at 0.1Hz), 2.2µF (approx 9kms of cable at 0.05Hz) & 5.5µF (approx 13kms of cable at 0.02Hz). Display 0~40 peak kV. Interconnect cable length 3m. RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control in travel cases weighing 50 & 35kgs respectively.Danbridge Type JP30A Insulation TesterDAN,Jp30A AU/NZDC high voltage insulation tester. Output voltage 0~3kV, 0~10kV, 0~30kV, in 3 ranges. Max output short circuit 2µA. Audible indication of ionisation. Current and voltage meters which may be used to calculate resistance.Megger BM80 Insulation TesterMEG,BM80 NZAnalogue/digital insulation and continuity tester. Insulation test voltages are: 50, 100, 250, 500, 1,000Vdc. Resistance resolution is 0.01 MΩ. Voltage range is 0~600Vac.

hi pOt teSterS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 59

ELEC

TRIC

AL P

OWER

Page 70: 2007 Rentalsolutionsguide-Aunz Low

electrical tranSducerS

Model Type Input Type (V) Input Ranges Output (V)CAT,CL-8-36 pH STICK Indoor two-pole tester 2~36kV

MEG,DH2-6M Duplex handspikes for 10AmΩ meter 30Vac/dc 20A max.

HIO,9661-01Clamp-on sensor

500A

500-mVacHIO,9669-CCT-1000A 1,000A

HIO,9667-FCT-5000A Flexible clamp-on sensor 500A/5,000A

UNI,p75-3C HYbRID-Dp

Clamp-on

2Vac/dc 7,5000A/1.5V

HIO,3290CLAMpONAC/DC dc to 15kHz 2840A peak 1mV/A

CHK,CR100S 100A

LEM,CURRENT pRObE10A

YEW,3228-11 High sensitivity clamp-on ammeter ac/dc current 50mA, 20A ac/dc 0~100mV ac/dc

ALG,C173 High sensitivity clamp-on ammeter & earth leakage Algodue only 0.001 ~ 1,000A 1mV~1V/A

HIO,3128 Clamp-on ammeter ac current 15A, 1.5kA 0~200mV dc

HIO,3285

Current clampac/dc current

200A, 2kA, 1kHz 0~1 ac/dc, 0~1 V

bEL,CG-120A 50, 500A 0 ~ 0.5 ac/dc

UNI,p75-3C 4, 7.5kA 0~2/ 0~1.5 ac/dc

HIO,3109 100, 250, 500,1kA 0~1 dc

CHA,D35N

ac current

1, 2, 3kA 0~5A ac

FLU,80I,100S 0~10, 0.5~100, 5~1000A 1mA/A

YEW,2215 Current shunt 1A, 1kA 0~50mV ac

JR,CT-005 ac current dc volts 1, 2, 5kA 0~1dc

ROb,543Rogowski coil

1A ~ 2MA 0~2 ac

LEM,LEM-FLExII 30, 300, 3kA 0~3 ac

LG,FIC-51E True RMS transducer

ac voltage

500V 0~5 dc

TR,M05 Instrument transformer 100V, 500V rms 0~5 ac rms

YEW,2261-01 Med voltage transformer (3.3kV) 220, 440V,2.2, 3.3kV 0~110 ac

MOR,FDT

Frequency transducer

0~20ac 50~1.6kHz 1~5 dc

CI,253/50240 ac 45~55 Hz

0~1mA

CT,891040-240 0~10 V dc

CT,891040-110 110 ac 55~65 Hz 0~10 V dc

CWE,230V Transducer ac voltage 230V 1mV/1V

CAR,3-TRANS Converter ac current 5A 0~10V dc

>NEW CATU C-8-36 Phasing Stick-Two pole Phase comparator for Indoor Use

CAT,CL-8-36 pH STICK AUDetect differences in voltage between any 2 points of an installation indicated by LED’s. Enables assessment of the residual voltage induced by nearby live lines or circuits, and differentiates it from the one provided directly from a high voltage source. Features, range of voltages 2kV~36kV, high luminosity, compact 0.62m with probes dismounted, high dielectric quality insulating material, 2 x 1.25m elements with removable probes, connected via a high-insulation lead, max use distance 2.25m (with probe extenders), operation testing with a checking device.

60

ELECTRICAL POWER

Page 71: 2007 Rentalsolutionsguide-Aunz Low

>NEWMegger DH2-6 Test Lead, 6m long for 10A mΩ Meters

MEG,DH2-6M AUDuplex handspikes (2) with spring loaded helical contacts test lead suitable for any 10AµΩ meters (like MEG,DLRO10, MEG,DLRO10x, CRO,DO7 and CHK,LMO5), Used for 4 terminal measurements with low resistance Ω meters, double, individually sprung, hardened and nickel plated, spike prods for good contact. potential lead and spike marked for easy identification, suitable for use in potentially corrosive conditions. Body moulding resistant to aviation “phosphate ester” fluids. Current rating: 20A max. Working voltage: 30Vac/dc. Resistance of leads: each lead 20mΩ maximum.

>NEW Hioki 9661-01 CCT-500A Clamp-on Sensors

HIO,9661-01 CCT-500A AU500A rated, 500mVac fs output, jaw 46mmØ. Rated input current 500Aac, rated output current 0.5Vac, accuracy (at 45~66Hz). Amplitude ±0.5%rdg, ±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous 550 Arms (45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions 77w x 151h x 42dmm, cord 3m. Suitable for Hioki models: 3196pQA, 3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any data logger/scope which takes up to 1.7mVac input.

>NEWHioki 9669-CCT-1000A Clamp-on Sensors

HIO,9669-CCT-1000A AUJaw 55mmØ, 80mmx20mm busbar. Rated input current 1000Aac, rated output current 0.5Vac, accuracy (at 45~66Hz) amplitude ±1% rdg, ±0.01% fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics 66Hz~5kHz (±1%), max. Allowable input continuous 1000A rms (45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions 99.5w x 188h x 42d mm, cord 3m. Suitable for Hioki models 3196pQA, 3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any data logger/scope which takes up to 1.7mVac input.

>NEW Hioki Flexible Clamp-on Sensor

HIO,9667-FCT-5000A AU10Hz~20kHz, 500/5000A rated, 500mVac fs output, jaw 254mmØ max. Rated input current 500Aac, 5000Aac, rated output current 0.5 Vac, accuracy (at 45~66 Hz). Amplitude ±2% rdg ±1.2mV, fs is the 3196 range value. phase ±1° or less. Frequency characteristics 10Hz~20kHz max. Allowable input continuous 10000Arms (45~66 Hz) max. Circuit voltage 1000Vac rms (insulated wire). Dimensions 254w x 86h x 30dmm. Sensor length 910mm. Suitable for Hioki models: 3196pQA, 3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any data logger/scope which takes up to 1.7mVac input.

>NEW Universal Technic Clamp-On AC/DC Current Probe 4000/7500A

UNI,p75-3C HYbRID-Dp AURanges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and external power supply, 3V operation. Safety sockets 4mm. Clamp is suitable for use with any instrument with an input range of 2Vac or dc, and an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders, oscilloscopes, and power quality analysers.

>NEW Hioki 3290 Clamp-On ac/dc HiTester

HIO,3290CLAMpONAC/DC AUCurrent Measurement at dc and from 1Hzac~1000Hz. Current Clamp Hioki 9693 Clamp-on ac/dc sensor ranges - 20, 200 & 2000A, jaw opening 55mm.

electrical tranSducerS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 61

ELEC

TRIC

AL P

OWER

Page 72: 2007 Rentalsolutionsguide-Aunz Low

electrical tranSducerS

>NEW CHK,CR100s Clamp-On CT 100A

CHK,CR100S AUSuitable for CHK power quality analysers like CHK pM20, pM30, pM30 plus and pM40.

>NEW HK,CR200 Clamp-on CT 200A~200mA, 2.2Ω Burden Class I

CHK,CR200 AUCT 200A~200mA, 2.2W burden Class I, IEC 185-1987. Suitable for any of the CHK powermonic power Quality Analyser like CHK,pM20, pM30 and pM30 plus units. Suitable for power cables size diameter up to 50mm.

>NEW LEM Current Probe 10A~1A for LEM,TOPAS 1000 PQA

LEM,CURRENT pRObE10A AUCurrent probe 10A~1A suitable for LEM Topas 1000 power quality analyser.

>NEW Cambridge Frequency Transducer 45~55Hz 240Vac

CT,891040-240 AUFrequency transducer from 45~55Hz with analogue output 0~10VDC. powered from 240Vac only.

>NEW Cambridge Frequency Transducers 891040 55~65Hz 110Vac

CT,891040-110 AUFrequency transducer for frequency from 55~65Hz with analogue voltage output 0~10Vdc. powered from 110Vac only.Algodue C173 Precision Clamp-on CT Microamps to 1KaALG,C173 AUHigh resolution clamp-on CT, for measuring differential and or earth loop or leakage current. Compatible with Algodue UpM6001 and the later UpM6100 analyser’s fourth current channel. Current range 0.001~1.2, 0.01~12, 0.1~120A & 1A~1.2kA. bandwidth 10Hz~3kHz. Max jaw opening 53mm.Bell CG-120A Current Gun (Clamp-on Probe)bEL,CG-120A AUClamp-on hall effect current probe. For primary 0~500A ac or dc (two scales 0~50 & 0~500). Frequency response dc to 1kHz. Output 0.5V full scale suitable for DMMs. Termination shielded 4mm banana plugs. Jaw opens to accept 19mmØ conductors. battery 9V alkaline typical life 100h.230Vac to 230mVdc TransducerCWE,230V AC NZInterface with output to 4mm banana male plugs suitable for connecting to DMM or recorder. Input range: 200~255Vac. Output: 0~255mVdc.Carrel & Carrel 5A ac to 10Vdc ConverterCAR,3-TRANS NZThree ac current to dc voltage transducers for use with 5A CTs and a recorder or logger. Input is 0~5Aac, output is 0~10Vdc. Accuracy is 0.5% between 1~5A at 50Hz.Fluke 1kA ac Current ClampFLU,80I-1000S NZThree ranges: 0~10A, 0.5~100A, 5~1,000A. Jaw opening is 55mm.HSI PSD Programable DC isolating interfaceHSI,PSD NZTransmitter for industrial interfacing to chart recorders and loggers. Input ranges: 10mV~200V, 50µA~50mA. bi-polar output ranges: -1V, 0~2V, 0~5V, 1~5V, 0~1mV, 0~2mV, 0~5mA, 1~5mA, 0~10mA 4~20mA. Accuracy: input/output 0.2%.Shimaden 4~20mA to 0~1V Isolating InterfaceSHI,20/0-1 NZSuitable for use with chart recorders, loggers and other devices requiring isolation from 4~20mA process signals.Hioki 3109 ac/dc Clamp-on Current MeterHIO,3109 AUCurrent meter with recorder outputs. In dc mode is a voltage waveform. Ranges 100, 250, 500A & 1kA. Measures to 2kA with reduced accuracy. Voltage range 10, 25, 50, 250 & 500 ac/dc. Accuracy 2.5%FSD. Recorder output 1V/FSD. Operates for 36h from dry batteries or via external ac.Hioki 3285 ac/dc Clamp-on Meter with Analog OutputHIO,3285 AURanges 200A/2kA ac/dc. Measure volts, ranges 30, 300 & 600V ac/dc. Frequency ranges 10, 100Hz & 1kHz. Display LCD, counts max 2,500 current, 3,750 voltage and 1,250 frequency. Output voltage 1V for 2,000 count fs for each current range, can select Rec rms output, response time about 250ms rise time, fall about 500ms. Select Mon for waveform output. 1V is produced for 1,000 count on full scale frequency range. Output not available for voltage measurements. Supplied with signal output cord, 4mm to BNC convertor, carry case and ac adaptor. Powered with internal 9V battery or ac adaptor.Yokogawa 3228-11 Clip-on AmmeterYEW,3228-11 AUHigh sensitivity, 9 ranges 50mA~20A. AC or dc operation. Frequency range 40Hz~1kHz. battery operated. Analogue output at full scale 100mV rms.Landis & Gyr FIC-51E Voltage TransducerLG,FIC-51E AUAC voltage to dc voltage transducer. Max input 500V. Output voltage 1Vdc per 100Vac input.Tech-Rentals,M05 Instrument TransformerTR,M05 AUPermits monitoring of ac power lines with low input level instruments. Input 100~500V rms. Output 1~5V rms. Distortion less than 0.5%. bandwidth 40Hz~10kHz.

62

ELECTRICAL POWER

Page 73: 2007 Rentalsolutionsguide-Aunz Low

electrical teSterSPhase Sequence Meter 110 - 600 volts 50 / 60 HzKYO,pSM8031 AUKYO,8031 MYphase indicator with open phase checker and phase indicator designed to check the presence of open phase and also the phase sequence by rotating disk and lamps. Check a wide range of 3ph power source from 110~600V. Operational voltage 110~600Vac, time limit for continuous >500V within 5min. Frequency response 40~200Hz(ac 110~200V), 40~400Hz(ac 200~600V) safety standard IEC61010-1 CAT.III 600V pollution degree 2 withstand voltage 2.2kVac for 5s. Dimensions 106L × 75W × 40Dmm, weight 350g approx. Cord 1.5m(R: red S: white T: blue)

Beha 5774E 3 Phase Sequence/Rotation IndicatorbEH,5774E AUFor determing the rotational direction and sequence of a 3ph supply. Necessary to pre-determine the correct rotational direction of 3ph motors.Kikisui PLZ1002W Electronic LoadKIK,pLZ1002W AU/MYVoltage range 3~110V. Current range 0~200A. In-built oscillator provides for dynamic load testing by switching between two different load levels. Load current may be remotely controlled by voltage or resistance signals. Multiple units may be operated in parallel. In-built digital volt/current meter. For dc inputs only.

Biddle 550005 Turns Ratio Test SetbID,550005 AUSingle phase (can be used on 3ph individual phase windings). Turns ratio 0.001~129.999. Exciting current 0~1A. Accuracy 0.1%. Hand cranked operation.AVO Penta-Plus DMM AnalyserAVO,pENTA-pLUS-DMM AUMultifunction meter for measuring 1 & 3ph volts ac, primary and secondary current, true and reactive power, amplitude and phase angle, and also frequency. Easily configured to measure the amplitude and phase angle between any 2 current or voltage inputs. Displayed simultaneously on a backlight graphic LCD screen. Internal memory records up to 60 test results. Logging via RS232C port. parallel printer port. Voltage 0~650Vac, 9 ranges with 0.1% resolution. Max 1kV. Current 0~100A ac in 11 ranges, with 0.1% resolution. phase angle 0~360O with 0.1O resolution. power true and reactive ±0-100kW & ±0~100kVAr. Frequency 45~65Hz. Timer 0~999.999. Line or battery operated, 3h continuous on full charge.Metrix MX120 Multicore Clamp-on MeterMET,Mx120 AUMeasures current in 1, 2, or 3 wire cables. No need to split cables or remove covers. Ranges 2 or 3 wire 0~40A, 1 wire 0~199.9A resolution 0.1A. Accuracy 5% with 2 or 3 wire oval or flat cable, 12% with round cable, 1.5% with single wire. battery operated. Display 3½ digit.Hioki 3282 Clamp-on Hi Tester (V, I, Hz & T)HIO,3282 AUMeasures True rms, peak, min/max & hold. Ranges auto/manual, current 30A, 300A & 1kA rms. Voltage 300/600V (1kVmax). Resistance 1/10kΩ. Frequency 40~100Hz & 66Hz~1kHz. Jaw capacity 46mmØ (50mm opening). Battery life approx 1.5h continuous.

Hioki 3128 Clamp-on Current Transducer HIO,3128 AUClamp-on current meter with recorder output. Ranges full scale 15A~1.5kA. Output 200mV dc full scale. Batteries not required. Output is intended only for low speed recorders.Yokogawa 2255-01 10A ~ 5A Current TransformerYEW,2255-01 AUInput 10Aac, output 5Aac, max circuit voltage 3.45kV, burden 15VA, accuracy 1% of rated value, bus bar connectors.Yokogawa 2215 Current Shunt YEW,2215 AU/MY50mV output, available in range of 1A~1kA.Crompton 235/50 Frequency Transducer CI,253/50 AUInput 240V ac, 45~55Hz, output 0 ~1mA.Moore FDT Frequency to Volts TransducerMOR,FDT AUInput range 6.5~12.5kHz at up to 20V peak to peak. Output 5Vdc at 12kHz.Yokogawa 2261-01 2.2kV Potential TransformerYEW,2261-01 AU3.3, 2.2kV, 440 & 220V primary to 110V secondary.Jacobs Radio CT-005 Current Transducer JR,CT-005 AURange 5kA, 2kA & 1kA. 1V dc output. Transformer can be split in two to accommodate cable or bus 22 x 55mm.

Universal Technic P75.3C dc/ac Amp ClampUNI,p75-3C AUMax current 7,500A dc & ac peak. bandwidth 1KHz. Min range 1kA. Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size 122 x 54mm or 100 x 64mm. Max cable size 83mm. battery 9V - life 100h. Output sockets 4mm. DC current gives dc output, ac current gives ac output, 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.Robinson 543 Linear ac Current TransducersROb,543 AUWide bandwidth and very wide dynamic range. Supplied with an open ended flexible coil of 3m length which may be wrapped around a very large conductor or power pole, etc. Frequency range 10Hz~10kHz with 1% accuracy. Current range for 1 wrap of coil 1A~2MA at 50Hz. phase error < 0.04deg. Min bending radius 60mm. External insulation is required for metallic conductor. Output voltage 2V rms ac waveform. Also dc rectified output. In-built digital display.LEM FLEXII 30, 300 & 3,000A TransducerLEM,LEM-FLExII AUFlexible wrap-around ac current transducer. Length 600mm. Ranges 30, 300A & 3kA. Frequency response 1~20kHz. Accuracy 1%. phase error 0.5O. Output 3Vrms @ full scale. Requires 3 units for 3ph. Designed for multimeters and oscilloscopes (4mm banana plug or bNC connectors) but can also be used with the DRA,808 (requires adaptor lead), or VOL,pM3000A. Other instruments may be attached providing the correct adaptor/transducer and connection is available. Operates for 100h from 2 x 9V batteries.

electrical tranSducerS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 63

ELEC

TRIC

AL P

OWER

Page 74: 2007 Rentalsolutionsguide-Aunz Low

PCU1-SP and PCUI-LTPrimary Current Injection Systems

www.maceyselectrical.com

• 5kA maximum output current

(higher overload currents for 2s)

• Multi-function digital timing system

• Digital true RMS memory ammeter

• Solid state switching

• 2000A and 5000A loading units

• Three range outputs on loading units

• Rugged, compact design

• Optional trolley mounting of system

PCU1-SP Additional Features

• Secondary injection up to 100A

• Direct reading CT ratio and polarity

FeaturesPCU1-SP and PCU1-LT

Page 75: 2007 Rentalsolutionsguide-Aunz Low

SMC PET-100-C Secondary Current Test Set SMC,pTE-100-C AU/NZAC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A & 10V/100A. Additional outputs ac voltage 0~220V at 1A (4A 1min), dc voltage 0~350V at 0.7A (2.8A 1min), dc voltage 0~250V at 0.25A, fixed 110V ac at 0.3A. Timer 1ms~99,999s. Additional functions include measurement of the phase angle between the voltage and the current output tap selected, and the measurement of the impedance of the load connected in the current output taps.Multi-Amp MS-2 High Current Test SetMUL,MS-2 AUDesigned to test overload relays, circuit breakers and earth fault trip devices. Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A, 24V/25A, 6V/120A & 3V/240A. Short term over current of several times the rated current ranges is possible. Digital current meter has read and hold facilities for short duration currents. Digital timer measures elapsed time between energisation and the test device operating.

>NEW T&R PCU1-SP with CT Ratio/Polarity and NLU5000A Loading Unit

T&R,pCU1-Sp NLU5000A AUMedium powered primary current injection system. Features 5kA maximum output current (higher overload current for 2s). Multi-function digital timing system. Digital true RMS memory ammeter. Solid state switching. 2000A and 5000A load units. Three range outputs on loading units. Rugged, compact design. Optional trolley mounting of system. Secondary injection up to 100A. Direct reading CT ratio and polarity. May be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range.

T&R PCU1/E 2000 A Primary Current Test SetT&R,pCU1/E AUComprises control unit and 2kA loading unit. Control unit includes timer, current and voltage meters, and variable output transformer. Current output to 100A at 5V ac, 50A at 10V ac. Voltage output to 25A at 240V ac. External loading unit output to 30A at 240V ac. Outputs 2kA at 0~3V, 1kA at 0~6V. Two units: weigh 35 & 45kg plus cables.

T&R 200 ADM Current Injection SystemT&R,200ADM AUSingle phase portable current injection system with main and auxiliary ac, dc current and voltage outputs. Output ranges main voltage, 10, 35, 100 & 240Vac & 240Vdc. Main current continuous, 1~25A, intermittent up to 200A. Auxiliaries stabilised dc isolated and protected 1.04A @ 24V~0.11A @ 220V. Variable 300mA @ 0~130Vac. Resolution 100mV, 1mA, phase 0.10. Timing range 0~999.999 with resolution 1ms. Metering LCD backlit true rms with a memory ammeter. Interface RS232. Protection main output duty cycle and auxiliaries, electronic thermal and fuse. Supply requirements 1ph 115~230Vac 50/60Hz 2.3kVA max.T&R CIT/LU2000 Primary Current Injection Test SetT&R,CIT AUComprises control unit and 2kA loading unit (LU). Control unit includes timer, current and voltage meters, and variable output transformer. External loading unit output 0~2kA, duty 5min on 15min off at 6V ac, continuous 0~1kA at 3V ac. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets each 3m long. Control unit connects to LU with supplied interface cable.

T&R 200A-3PH/ED 3 Phase Current Injection TesterT&R,200A3pHEDIT AU0~200A/phase output capacity. power supply 4 wire 5A/phase 3ph 240/415V. Typically 10A 5 pin 3 phase socket outlet HpM.

current injectOrS

electrical teSterSHioki 3283 Clamp-on Leakage Current TesterHIO,3283-LEAKAGE-TES AUAnalyser functions for filtering and output signals. Wide bandwidth 5Hz~15kHz, high sensitivity with a full scale of 10mA, ranges 10mA, 100mA, 1A, 10A & 200A primary. Resolution 10µA, high accuracy at ±1%,True rms measurement. Output monitor and record modes, ac/dc output 1~2V full scale. battery 9V approx 40h.

Equimp HT2035 Electrical TesterEQU,HT2035 NZComplies with CEI 64-8 & CEI 64-4. Eight instruments in the one case which includes printer & RS-232C interface.Tests are:- 1. Low Ω range 0~20Ω, resolution 0.01. 2. 2 & 3 wire earth resistance measurement, range 0~1,999Ω. 3. Insulation resistance 0~199.9MΩ, 250, 500 & 1,000V. 4. RMS ac 0~500V, resolution 1. 5. Short circuit loop impedance 0~1,999Ω, resolution 0.01. 6. Fault loop impedance measurement 0~1,999Ω. 7. Fault loop resistance 0~1,999Ω. 8. RCD tester.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 65

ELEC

TRIC

AL P

OWER

Page 76: 2007 Rentalsolutionsguide-Aunz Low

>NEW Powerware 700VA/420W Line Active UPS

pOW,700VAUpS AUprotection in the 700~3000Va range. Input Voltage Range: 120/140/160-276 Vac. Frequency 45~65 Hz. plug and play tower, under monitor, or 2U rackmount. Line-interactive.

Sola 66-102-8 2kVA Electronic Power Conditioner 2kVASb,66-102-8 AUInput voltage 240V +15% & -25%. Efficiency 94%. Distortion 0.5%.Sola 210-26-725 2.5kVA Power ConditionerSb,210-26-725 AUInput range 240V ±40% for +5% & -8% regulation. Max distortion on linear loads 3%, on typical computer loads 5%. Efficiency 90%.Sola 0601-2000A 2kVA On-line UPSSb,0610-2000A AUSb,0610-2000VA NZRun time 10min or 25min at half load. Novell/RS232 communications interface included providing relay contacts for mains failure and low battery, input for remote shut down, and RS232 send/receive, all via a Db9 connector.APC Pro 1000 UPSApC,1102 NZ1 KVA line interactive ups with built-in filters for sags, surges and transients. Switches to battery power in 20ms in the event of a power outage.

Compaq On-line 700 Watt UPSCOM,T700UpS NZ

Eaton Corp Powerware 9120 2kVA Online UPSEAT,9120-2KVA NZThe double conversion online PW9120 with its wide input voltage is capable of working with mains power in most conditions without discharging batteries. Capacity 2kVA 12min IEC 10 A 5 Aust 10A 215 x 470 x 365 mm.Sola 625 Battery PackSb,625-bATT NZ

Sola 625-3000VA On-line UPSSb,625-3000VA NZOutput regulation is ±3%, run time at full load is 8min or 20min at half load. 125% overload capacity for 10s.Sola Basic 3500VA 110V OP Power ConditionerSb,63-25-735 NZ3500VA fero resonant power conditioner. 230V input and 110Vac output. Filters out sags, surges and transients.APC SU3000 3kVA On-line UPSApC,SU3000 AURun time 5min at full load. Network software included. Weight 60kg.Chloride Powerlan 2.2kVA UPSCHL,2200 AUSinewave output. Dual pC interfaces. Typical run time 10min. Weight 43kg. Vigilant 7 network interfacing software included.Chloride Powerlan 5kVA UPSCHL,5000 AUSinewave output. Dual PC interfaces. Typical run time 10min. Weight 120kg. Vigilant 7 network interfacing software included.Chloride Active 2kVA Double Conversion UPSCHL,ACTIVE2000 AUDouble conversion sinewave output. Dual PC interfaces. Typical run time 20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V ac 1ph + N ±3%. Efficiency >88%. Dimensions 200w x 875d x 350hmm. Weight 81kg. MopUpS professional software for system monitoring and shutdown included. USb port & RS232 communication port for UpS monitoring and management.

Model Type Capacity (VA)

COM,T700UpS

UpS

700

pOW,700VAUpS 700

ApC,1102 1,000

EAT,9120-2KVA 2,000

Sb,0610-2000A 2,000

Sb,0610-3000VA 3,000

CHL,2200 2,200

CHL,ACTIVE2000 2,000

CHL,ACTIVE30003,000

ApC,SU3000

CHL,5000 5,000

Sb,66-102-8Conditioner

2,000

Sb,210-26-725 2,500

Sb,63-25-735 3,500

HIO,bATTERYTEST Battery

Sb.625-bATT battery pack

pOWer line cOnditiOner/upS

66

ELECTRICAL POWER

Page 77: 2007 Rentalsolutionsguide-Aunz Low

pOWer line cOnditiOner/upSChloride Active 3kVA UPSCHL,ACTIVE3000 AUDouble conversion sinewave output. Dual PC interfaces. Typical run time 20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V ac 1ph + N ±3%. Efficiency >90%. Dimensions 200w x 875d x 350hmm. Weight 81kg. MopUpS professional software for system monitoring and shutdown included. USb port & RS232 communication port for UpS monitoring and management.

Hioki Battery HiTesterHIO,3551bATTERYTEST AUTakes on-the-spot measurements of the internal resistance, voltage and temperature of lead-acid batteries, principally for UpS and similar applications, without needing to shut off the battery. Instantaneous results, on a three-rank scale of pass, Warning, or Fail, using a composite decision based on the internal resistance and the voltage. Resolution of 1µΩ, necessary for high capacity batteries (of at least 500Ah). Includes Hioki 9460 clip type temperature leads.

>NEW Dimmer Dot Variable AC Voltage Auto Transformer 3 Phase 23~28A

VAR,D-283-Ob AUManual operated air cooled; Input 400/415V, 50Hz. Output 0~415/470V. 23-28A. Total Weight 95kgs.Ferguson 115-2000 2kVA 240/115V TransformerFER,115-2000 AU

Ferguson 115-1,000 240V 1kW TransformerFER,115-1000 AU240~115Vac, 1kVA stepdown transformer.

Variac 2kVA 0~260Vac OutputVAR,2000 AU

Variac 3kVA 0~260Vac OutputVAR,3000 AU/MY

Variac 16kVa-3 3ph 20A VAR,16000-3 AU

Variac 6500-3 3ph 6.5kVAVAR,6500-3 AU/NZVariac 3ph 6.5kVA. 0~470Vac output for 415Vac input, max current 8A/ph.

Model Type Phases VA Output (VAC)

FER,115-2000 Power Transformer 12,000

115FER,115-1000 1,000

VAR,D-283-Ob Auto Transformer 3 16,000 0~470

VAR,2000

Variac

20000~260

VAR,3000 3,000

VAR,16000-33

20A/ph0~470 ph-ph

VAR,6500-3 8A/ph

pOWer tranSfOrmerS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 67

ELEC

TRIC

AL P

OWER

Page 78: 2007 Rentalsolutionsguide-Aunz Low

Elgar 501 ac Power SourceELG,501 AUAC power amplifier. Operates from 240V 1ph ac. Output ranges on tapped transformer 0~65, 0~130, 0~260Vac. Output power 500VA. Alternative oscillators available for 10Hz~10kHz operation. Amplifier output rated over 45Hz~5kHz. Two units may be connected for 1kVA output. Three units may be used with a single 403 oscillator to give a 3ph output at 1.5kVA.Behlman BL1350C-2 1350 VA Power AmplifierbEH,bL1350C-2 AUAC power amplifier with oscillator. Max power output 1.35kVA. Max current 10A on 0~135V range, 5A on 0~270V range. Output frequency 45~500Hz. External frequency synchronising input. Remote 0~10Vdc programming of output frequency and voltage. Digital true rms readout of voltage and current. Units may be stacked for higher power or 2 & 3 phase operation.Honda EU3000is Generator 240V/3kVA Inverter OutputHON,EU3000IS AU3kVA /240Vac generator inverter type. Working on petrol.

Rediline DA3179 12/240V dc-ac InverterRED,DA3179 AU/MYMotor generator. 12Vdc to 240Vac sinewave output. Continuous rating 400W. Intermittent use 600W. Lower duty cycle 50% on, 25% off, 1.2kW, auto starts on load. Overload protected. Weight 12kg. Overall frequency regulation 47~53Hz.

Power Conversions 250I InverterpC,250I AU250W sine wave inverter. 12Vdc input.Power Inverter 300W 24Vdc Output 240VpC,300I-24 AUSinewave inverter. Output power continuous (peak) 300W (1kW). Frequency 50Hz ±1%.230 to 115 VAC Transformer 1 kVATRA,230-115 NZMaximum power is 1kW. USA power socket.Ebbett 1,5kW DC to AC InverterEbb,12/1500 NZ12Vdc~240Vac 50Hz sinewave inverter. Continuous rating 1,000VA. Intermittent use 1,500VA. Surge (motor start) 2,000VA. Overload protected with automatic soft start. Output 230Vac ±5%. Frequency 50Hz ±0.5. Three pin outlet socket.Yamaha EF3000iSE 3kVA Petrol Generator/Inverter SetYAM,EF3KISE AUOutput ac 3kVA 2.8kW @ 240V 50Hz, max harmonic distortion 2.5% (mains supply can exceed 5%), 12Vdc @ 14A. Sound attenuated enclosure (level 57db(A) @ 7m) with 4 wheels. Dimensions 680w x 445d x 555hmm. Dry weight 70kg. Engine 4 stroke, air cooled ohv, fuel tank 13L (unleaded), duration at 25% load 20h with auto throttle on. Electric and pull start.

ac SOurceS/inverterS/generatOrS

Model Type VA Output (VAC)

ELG,501AC power Amp 0~270

bEH,bL1350C-2

RED,DA3179 Motor generator 12 V 400 240

PC,250I Sine Wave Inverter 12 V 250 250

pC,300I-24 power Inverter 24 V300

240pC,300I-12 Power Inverter 12 V

HON,EU3000is Petrol Generator 3000

YAM,EF3000iSE petrol Generator/Inverter Set 3000

TRA,230-115 Transformer 1000 115

68

ELECTRICAL POWER

Page 79: 2007 Rentalsolutionsguide-Aunz Low
Page 80: 2007 Rentalsolutionsguide-Aunz Low

data lOggerS

Data Loggers Analogue in(Ch)

Digital in

(Ch)

Digital out(Ch)

dcsupply

VoltageRanges RTD Strain

Gauge TC Comms Memory SampleRate (Hz)

FlashcardMB

DE,DT605 10(30 unbal) 5 5

Yes

25mV~100V

Yes Yes

Yes

RS23213.65k

1 SRAM 1DE,DT605-3 166.538k

DE,DT800 12(42 unbal) 16 8 10mV~10V 10baseT/

RS23264M

100kHz 64DE,DT800-4pRO 64M

HIO,8421-0116

100mV~60VYes

No LAN8Mb 256

HIO,8421-51

HIO,8422-51 32 No 8Mb 512

YEW,DA100-40CH 40 20mV~50V Yes RS232 0.5

FOU,DAQpRO8 0~50mV

0~10V Yes No YesJ,K USb 512kb 0~10kHz

No

FOU,DAQpRO-2

TIN,TGpR-0804

1

4~20mA

No No

RS232 15.9k 1s

TIN,TGpR-0704-10VDC 0~10V dc CommsRS232C

TIN,TGpR-0704-2.5V 0~2.5V RS232C

Memory Recorders for transient & continued signals

Analogue in (channels)

Digital in (channels)

Chart Paper(mm)

Chart Speed(mm/s) FDD Voltage Ranges Memory

per ch RS232 Sample Rate

HIO,88354

16

100

9 Yes 100mV ~400V

100kW

No 1MHzHIO,8835-01 1Megaword

HIO,8841 8 200 1M

HIO,8842 16 200 2M

HIO,8860 8 16 200 20 No No Var

YEW,ORM1300 16

200 100Yes

100mV ~500V128k

100kHzYEW,ORM1200

8YEW,ORp1200 3k

YEW,DL708E 100 Yes 50mV ~800V 1 M Yes 10MHz

Hybrid & Pen Recorders Analogue in (Ch)

Chart Paper(mm)

Chart Speed dc Supply FDD Voltage Ranges

(V) TC RTD Sample Rate(Hz) RS232

YEW,3057-22 2 150 10mm/s 10mV – 50

YEW,3712-31 3 2501,200mm/min 10mV – 200

Yes

135Yes

YEW,3712-41 4 250

YEW,3750 10150

1,500mm/h 20mV – 50 0.5 YesYEW,3750-DC 20 Yes Yes

YEW,3760 30 250

YEW,DR130 20 150 Yes

70

DATA ACQUISITION & RECORDING

Page 81: 2007 Rentalsolutionsguide-Aunz Low

data lOggerSFourier DAQPRO 8 Channel Data LoggerFOU,DAQpRO AU/NZportable, hand held, battery operated 8 channel data logger. 16-bit resolution, built in graphic LCD, for setting up, graphical display of logged data. pC communications via USb interface. Signal inputs 0-24mA, 0-50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range -25~150OC, pT100 range -200~400OC, T/C ranges J type, -300~1500OC, K type -250~1100OC, T type -200~400OC. Frequency input one channel only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000 counts. Memory capacity 512Kb, sampling rates from 1S/Hr to 4,000S/sec. Supplied with analysis and setting up software.

Fourier DAQPRO8 Batter Operated hand held 8 Channel Data LoggerFOU,DAQpRO-2 AUportable, hand held, battery operated 8 channel data logger. 16-bit resolution, built in graphic LCD, for setting up, graphical display of logged data. pC communications via USb interface. Signal inputs 0-24mA, 0-50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range -25~150OC, pT100 range -200~400OC, T/C ranges J type, -300~1500OC, K type -250~1100OC, T type -200~400OC. Frequency input one channel only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000 counts. Memory capacity 512Kb, sampling rates from 1S/Hr to 4,000S/sec. Supplied with analysis and setting up software.DataTaker 1Mb PCMCIA Card for DT Series 2DE,DT-MEM1024 AUMemory card for DataTaker DT600 series loggers. Capacity 1.024Mb.DataTaker DT500/600 Expansion ModuleDE,CEM-AD AUChannel expansion module for DT500 & DT600 data loggers. Adds 10 differential analogue and 20 digital state inputs. Also adds 10 digital outputs.DataTaker DT5LTP-R One Channel LoggerDE,DT5LTp-R AUOne channel platinum resistance probe temperature logger. Range -50~50OC up to 0.1 resolution, -50~250OC up to 0.3 resolution. Memory store up to 4,048 readings. External probe. Lithium battery.DataTaker DT800 Data LoggerDE,DT800 AU/NZUniversal input channels 12 balanced or 42 unbalanced analog channels. Eight bi-directional digital channels & 8 digital input channels. Solid state multiplexer protected to ±40V. Max in/out voltage ±12V. Serial sensor channel can be used with GpS systems. Measures V, 4~20mA, strain, TC, RTD etc. Sampling rate 200Hz up to 100kHz in burst mode. Instrument has RS232, RS422, USb, Ethernet (10baseT) & pC card modem communications. plugable 64Mb memory card stores up to 300,000 (compressed) readings per Mb. Instrument stores 600,000 (compressed) readings in internal memory. Total memory capacity 10.2Mb (compressed).

Datataker DT800 Data Logger with Delogger 4Pro & Transit CaseDE,DT800-4pRO AUUniversal input channels 12 balanced or 42 unbalanced analog channels. Eight bi-directional digital channels & 8 digital input channels. Solid state multiplexer protected to ±40V. Max in/out voltage ±12V. Serial sensor channel can be used with GpS systems. Measures V, 4~20mA, strain, TC, RTD etc. Sampling rate 200Hz up to 100kHz in burst mode. Instrument has RS232, RS422, USb, ethernet (10baseT) and pC card modem communications. plugable 64Mb memory card stores up to 300,000 (compressed) readings per Mb. Instrument stores 600,000 (compressed) readings in internal memory. Total memory capacity 10.2Mb (compressed). Supplied with Delogger 4pro & Ip67 pE-800 portable enclosure with mounting frame.

DataTaker DT605 Data LoggerDE,DT605 NZInput capacity 100V. LCD display enabling use as a measuring instrument if preprogrammed for channel parameters. Ten differential or 30 single ended channels. Channels/sec 25. Digital inputs 4TTL/CMOS. Three counter channels up to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LED’s. Internal memory up to 11,000 readings. Optional memory card to 170,000 readings. RS232C data communications port and RS485 port for networking up to 32 loggers. Maths processing included. Inputs voltage 25mV~2.5Vdc & 100Vdc. Max sensitivity 2µV. Current 0.25~25mA. Current loop 4~20 mA. Resistance up to 7kΩ. Thermocouples b, C, D, E, G, J, K, N, R, S and T from -250~1,800OC. Thermistors and RTD’s. Strain gauges. Supplied with Determinal and Delogger software. Operates from internal battery, external battery or ac mains.

Data Taker DT605-3 Series 3 Data LoggerDE,DT605-3 AUInput capacity 100V and built in SRAM Card Slot. LCD display enabling use as a measuring instrument if pre-programmed for channel parameters. Ten differential or 30 single ended channels. Channels/sec 25. Digital inputs 4TTL/CMOS. Three counter channels up to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LED’s. Internal memory up to 166,530 readings. Optional 1Mb memory card to 343,980 readings. RS232C data communications port and RS485 port for networking up to 32 loggers. Maths processing included. Inputs V 25mV~2.5Vdc & 100Vdc. Max sensitivity 2µV. Current 0.25~25mA. Current loop 4~20mA. Resistance up to 7kΩ. Thermocouples b, C, D, E, G, J, K, N, R, S and T from -250~1,800OC. Thermistors and RTD’s. Strain gauges. Supplied with Determinal and Delogger software. Operates from internal battery, external battery or ac mains.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 71

DATA

ACQ

UISI

TION

& R

ECOR

DING

Page 82: 2007 Rentalsolutionsguide-Aunz Low

data lOggerSHioki 8421-01 16 Channel Data Logger with Colour DisplayHIO,8421-01 AUSixteen analogue, 4 pulse input channels data logger with colour display, pCMCIA card slot, LAN interface built in, TCp/Ip communication supports real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVdc, 1Vdc, 10Vdc, 60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5~26) R, S, b, -100~100OC, -200~500OC, -200~2,000OC, RTD pt100 -200~800OC. Pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent upon type of input signal. Internal Memory 8Mb, 256Mb Flashcard, 9334 logger communicator software, 9642 LAN cable, 9641 pulse signal input cable all supplied.Hioki 8421-51 16 Channel Data Logger with Colour DisplayHIO,8421-51 AUSixteen Analogue, 4 pulse input channels data logger with colour display, pCMCIA card slot, LAN interface built in, TCp/Ip communication supports real time pC logging, FTp, SMTp and HTTp. Signal inputs- 100 mVdc, 1Vdc, 10 Vdc, 60Vdc, 1-5Vdc f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, b, -100~100OC, -200~500OC, -200~2000OC, RTD pt100 -200~800OC. Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type of input signal. Internal Memory 16MW, 512Mb pCMCIA FLASH card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse signal input cable all supplied. Improved common mode rejection- 100db or better when 50/60Hz, 140db or better when 50Hz, using ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling when using Pt100, improved temperature characteristics.Hioki 8422-51 32 Channel Data Logger LoggerHIO,8422-51 AUThirty two analogue, 4 pulse input channels data logger with colour display, pCMCIA card slot, LAN interface built in, TCp/Ip communication supports real time pC logging, FTp, SMTp and HTTp. Signal inputs: 100mV, 1, 10 & 60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, b, -100 ~100OC, -200~500OC, -200~2,000OC. pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs & 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent upon type of input signal. Internal Memory 8Mb, 512Mb pCMCIA FLASH card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse signal input cable all supplied.

Yokogawa MV200 Twenty Channel LoggerYEW,MV200 NZTwenty channel voltage, RTD and thermocouple logger. Color LCD display 10.4” TFT, removable pCMCIA ATA flash memory card. Supports data collection over ethernet networks. Supplied with RJ-45 cable and standard software.Yokogawa Data Logger for PC AcquisitionYEW,DA100-40CH AUpC based datalogger with dc supply. Channels 40, 50V max input 0.05% basic accuracy. Accepts RTD and TC inputs. Must be used in conjunction with a PC includes analysis software. Scan rate 2s.

Yokogawa 2423A Six Channel LoggerYEW,2423A17 NZPortable voltage and thermometer logger. Ranges are 10, 1 & 0.1V. Type K, E, J, T, R, S, b, L, U thermocouples. Memory stores 14,000 data points. Min logging interval is 10s. Large LCD display, analogue and RS232 output. Supplied with software for uploading data to CSV or TxT format.

>NEW Hioki 3632-20 Temperature Logger with Internal Sensor Only

HIO,3632-20 AUTemperature logger (1 channel) includes 1 x RS232C & 1 x USb communication base, utility software, RS232C and USb interface cables. Temperature range -20~+70ºC. Accuracy -20~-0.1ºC +/-1.0ºC. 0~35ºC +/-0.5ºC, 35.1~70ºC +/-1.0ºC. Internal thermistor sensor, water resilience Ip67. Built in LCD.

Hioki 3641-20 Temperature/Humidity Logger with RS-232C & USB HIO,3641-20 AU/MYIncludes 1 x RS232C & 1 x USb communication base, utility software, RS232C & USb interface cables. Temperature range -40~85OC, humidity range 0%~100%RH. Accuracy temperature -40~-0.1OC ±1, 0~35OC ±0.5, 35.1~70OC ±1 & 70.1~85OC ±2. Humidity typical between ±5~±10%RH depends on temperature and humidity range.Hioki 3641-20-Kit of 8 Temperature & Humidity LoggersHIO,3641-20-KIT AUKit of 8 x temperature and humidity loggers. Includes 1 x RS232C and 1 x USb communication base, utility software, RS232C and USb interface cables. Temperature range -40OC~85OC, humidity range 0.0%RH to 100% RH. Accuracy: Temperature -40~-0.1OC +/- 1.0OC , 0.0~35OC +/- 0.5OC, 35.1~70OC +/- 1OC, 70.1~85OC +/- 2OC. Humidity typical between +/-5 to +/-10% depends on temperature and humidity range. 8000 data points x 2 channels, recording interval 2,5,10,15,20,30 sec,1,2,5,10,15 ,20,30,60 min.

Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles FOU,MICROLOG-KIT AUSet of 5 temperature and humidity loggers mounted in RF transmitter cradles, one receiver for PC. Transmission range up to 300m or RS232C & USb interface also included if direct connection to pC for down loading required. Temperature range -30~50OC, accuracy ±1O, 0~100%RH accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points between 2 channels. User defined sampling rate from 10s~2h. MicroLog Plus management control software included to control and monitor all the loggers remotely on PC within transmission range.Escort Temperature Humidity Logger Set of 10ESC,HUM/T-KIT AUESC,HUM-KIT NZIncludes software and communication base for down loading of data from loggers to a PC. Data presented in table or graph form. Max sample rate 1min.

72

DATA ACQUISITION & RECORDING

Page 83: 2007 Rentalsolutionsguide-Aunz Low

data lOggerSEscort Analogue Adaptor ESC,ANALOGUE NZAnalogue adaptor for dc voltage and dc current inputs. Inputs: 0~20mA, 0~2 VDC, 0~10Vdc.Escort Four Channel Temperature Logger ESC,4 ExT NZRange -20~60OC. Resolution 0.3OC. Accuracy 0.5OC. Stores 30,000 readings. Supplied with software, interface and 3m long temperature sensors.Escort Three Channel Low Temperature Logger ESC,3ExT-LO/SS NZRange -40~40ºC, accuracy 0.5ºC, resolution 0.3ºC. Supplied with 3 temperature sensors and software.Escort Internal Temperature LoggerESC,INT-LO NZSingle channel low temperature logger. Range -40~40ºC, resolution is 0.5ºC, accuracy is 0.3ºC. Can be immersed in liquid. Stores 24,000 readings. Supplied with software and serial interface for uploading data.Escort pH AdaptorESC,pH-ADApTOR NZGlass electrode type pH adaptor probe. Range 0~14pH, resolution 0.015pH. User calibration via offset and slope adjustment screws. Supplied with 10m temperature compensation probe. WARNING!! Do not use the electrode in perchlorate, silver, sulphide or any hydrofluoric solutions containing more than 1M acid or base, or at temperatures more than 50ºC. Use at high temperatures may shorten the life of the electrode.Escort Autoclave LoggerESC,AUTOCLAVE NZTemperature logger suitable for use in autoclave sterilizers. Temperature range is 25~150ºC, resolution: 0.5ºC, accuracy: ±0.5ºC. Rated to 150ºC for 30min or 125ºC for indefinite. Maximum of 60min endurance for dry heat oven @ 150ºC. Stainless steel body with 1 external sensor, stores 2000 readings in its memory. IP68 rated to 5bar. Supplied with calibration certificate, software and serial interface for programing & uploading.

Tiny Tag One Channel 0~20mA Current Input Logger TIN,TGpR-0804 AULogger 4~20mA single channel. Readings 15,900. Re-scalable Ip68 78w x 50d x 34hmm. Two level alarm leds. Accuracy 0.6% 0.1mA.Tiny Tag TGPR~0704~10Vdc Data LoggerTIN,TGpR-0704-10VDC AUSingle channel 0~10Vdc logger , 8 bit A to D resolution. Stores 15,900 readings. 2 alarms with red indicator LED. Reading interval from 1s~10d. Range: 0~10Vdc, max input 14V, accuracy ±40mV, ±1% rdg, 400kΩ impedance. Battery operated.Tiny Tag TGPR~0704~2.5Vdc Data LoggerTIN,TGpR-0704-2.5V AUSingle channel 0~2.5V logger, 8 bit A to D resolution. Stores 15,900 readings. 2 alarms with red indicator LED. Reading interval from 1s~10d. Range 0~2.5V range, max input 3.5V, accuracy ±10mV. battery operated.Testo 177-H1 Logger with DisplayTES,177-H1 MYparameters: Humidity/Temp/Dew point. Sensors: Humidity Sensor/NTC(internal). No of Channels: 4 CH. Measuring Range: 0~100%RH & -20~+70 celcius(internal). Memory: 48,000 readings.Testo 177-T4 Logger with DisplayTES,177-T4 MYparameters: Temperature(C/F). Sensors: Thermocouple Type-K. No of Channels: 4 CH(external). Measuring Range: -100~+1000 celcius(external). Memory: 48,000 readings

Vishay 2100 Eight Channel Instrument AmplifierVIS,2100 AUEight channel signal conditioner/amplifier system comprising 4 dual amplifiers with power supply, digital output display and rack frame. Accepts low level signals and conditions and amplifies them to drive recorders. bridge balancing for quarter (120 & 350Ω), half & full bridge (50~1kΩ). Quarter bridge dummy resistors provided. Gain 100~2100. bandwidth dc ~5kHz at 0.5db, 13kHz at 3db. Output ±10V @ 30mA, 50mA into 150Ω, 100 mA into 15Ω. Type 2130 digital readout can be switched to each output in turn and also to an external source. Ranges ±1,999mV & 19,999mV.

inStrumentatiOn amplifierS

Yokogawa ORP1200 8 Channel Memory RecordersYEW,ORp1200 AU/MYIn-built waveform display. Input ranges 100mV~500V. Max input voltage is 500V peak or 350V rms ac. Memory 32k per channel, may be combined for 2 channel 128k operation. Memory may be divided into 16 blocks of 2k. 128k memory at 1kHz sampling (20 points of 50Hz cycle) gives 128s storage. Real time recording 10mm/hr~100mm/s. Real time recorder with memory trigger facility. 4 triggers including high, low, rise, fall, with and/or facility. x-Y operation with up to 4 channels. Memory card facility for storing memory dumps and setups. Memory card not included.Yokogawa ORM1300 16 Analogue Channel Memory RecordersYEW,ORM1300 AUSimilar to YEW,ORM1200 except it has 16 analog channels rather than 8.

Yokogawa ORM1200 8 Channel Memory RecordersYEW,ORM1200 AUSimilar to YEW,ORp1200 except it has 128K RAM per channel (ie. 512K when used as a 2 channel recorder) includes FDD.Yokogawa DL708 8 Channel Recorder/Digital ScopeYEW,DL708E MYEight channels 10M/s sampling 10 bit 8M word of memory, 1.2Gb HDD (100k/s sampling continuously to disk). In-built printer, FDD, RS232, GpIb and VGA. Input ranges 5mV/div~200V/div . 800V isolated input capability (using x10 probes). Input filters, FFT, color display, measurement of 26 waveform parameters. Simple and advanced trigger including a window trigger.

memOry recOrderS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 73

DATA

ACQ

UISI

TION

& R

ECOR

DING

Page 84: 2007 Rentalsolutionsguide-Aunz Low

memOry recOrderS

>NEW Hioki 8860 8 Channel High Speed Memory Recorder

HIO,8860 AUHigh speed memory recorder, 20MS/s sampling rate, 8 analog channels, 16 logic channels, built in printer. 512MW or direct access memory, 60GB hard drive built-in, pC card type II slot up to 4Gb ATA flash card (optional) USb, LAN interface and large colour screen.

>NEW Hioki 9725 Memory Viewer Software

HIO,9725 AUData processing software for Hioki 8860 High Speed Memory Recorder. Functions: file loading, maximum loadable data size 2GW file saving, measurement of data binary, partial saving between A/b cursors is possible. Screen images BMP and PNG, calculation results. Display of saved binary files, displayable channels per sheet analog 32, logic 16 channels. Displayable sheets 16.

>NEW Hioki 8938 FFT Input Signal Module

HIO,8938 AUFFT Module with anti-aliasing filter. Frequency range dc to 400kHz, sampling rate 1MS/s. Maximum input voltage 400Vdc, 240Vrms.

Hioki 8810 4 Channel Memory RecordersHIO,8810 AU4 functions: memory x-T, continuous x-T, memory x-Y, continuous x-Y. 3 channel x-Y is possible. Input amplifier bandwidth 0~100 kHz limited by max sampling rate of 4µs in memory mode and 100~200µs in continuous modes. Memory size per channel 8k with 8 bit resolution. paper 110mm x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in memory mode giving 32ms~1,600s display. Continuous mode chart speed 1s/div~50min/div in 12 steps. Input floating 10mV/div~5V/div in 12 steps with fs offset. Internal trigger with level control. External trigger TTL or contact closure. Successive transient recording possible. Multiple recorder synchronization possible.

Hioki 8811 3 Analogue 8 Digital Channel Memory RecordersHIO,8811 AU/MYFour functions, memory x-T, continuous x-T, memory x-Y & continuous x-Y. Three channel x-Y is possible. Input amplifier bandwidth 0~100kHz limited by max sampling rate of 4µs in memory mode and 100~200µs in continuous mode. Memory size per channel 8k with 8 bit resolution. paper 110mm x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in memory mode giving 32ms~1,600s display. Continuous mode chart speed 1s~50min/div in 12 steps. Input floating 10mV~5V/div in 12 steps with full scale offset. Internal trigger with level control. External trigger TTL or contact closure. Successive transient recording possible. Multiple recorder synchronization possible. Hioki 9306 and 9307 probes optional.Hioki 8835 4 Channel Waveform & 16 Channel Memory RecorderHIO,8835 AUMemory 12 bits x 100k per channel or 500k for a single channel. Analog input channel ranges 10mV~50V/div, 10x div, 400Vdc, 240Vac rms max. In-built FDD and type-III pC card slot. Fastest sampling rate 1MHz. paper 110mm x 30m. Colour TFT display. Additional functions include waveform parameter calculation including rms values, area value, rise and fall times. AC mains operation.Hioki 8835-01 4 Analogue, 16 Logic Channel Waveform RecorderHIO,8835-01 AUMemory 12 bits x 1 megaword per channel or 4 megaword for a single channel. Analog input channel ranges 10mV~50V/div, 10x div, 400Vdc, 240Vac rms max. In-built FDD & type-III pC card slot. Fastest sampling rate 1MHz. paper 110mm x 30m. Colour TFT display. Additional functions include waveform parameter calculation including rms values, area value, rise and fall times. AC mains operation. Logic probes must be rented seperately.

Hioki 8841 8 Analogue, 16 Channel Memory RecorderHIO,8841 AU/NZMemory 12 bits x 4 megawords/ch for 2 analog ch, to 1 megawords/ch for 8ch. In-built FDD, type III pCMCIA card slot (for flashcard & HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real time record, rms, real time/memory, x-Y memory, FFT. Trigger functions level, window in, window out, voltage drop, rms level, cycle, logic pattern trigger 1,0 or x (disregard). When using logic channels, logic probes must be rented seperately. Measurement range 400Vdc, 240V rms, low pass filters 5Hz, 500Hz, 5kHz or 100kHz, input coupling dc, GND, ac. Large 10.4” colour TFT display for settings and waveform display, wide thermal printer fitted. On screen help function. All settings and waveforms can be saved to media, waveforms can be saved as binary, text or bmp files.

74

DATA ACQUISITION & RECORDING

Page 85: 2007 Rentalsolutionsguide-Aunz Low

memOry recOrderS

Hioki 8842 16 Analogue, 16 Logic Channel Waveform RecorderHIO,8842 AUMemory 12 bits x 16 megawords/ch for 2 analogue ch, to 2 megawords/ch for 16 ch. Analogue input channel ranges 10mV~50V per div, 10x div, 400V dc, 240V ac rms max. In-built FDD, type III pCMCIA card slot (for flashcard & HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real time record, rms, real time/memory, x-Y memory. Trigger functions level, window in, window out, voltage drop, rms level, cycle, logic pattern trigger 1,0 or x (disregard). When using logic channels, logic probes must be rented seperately. Measurement range 400V dc, 240V rms, low pass filters 5Hz, 500Hz, 5kHz, or 100kHz, input coupling dc, GND, ac. Large 10.4” colour TFT display for settings and waveform display, wide thermal printer fitted. On screen help function. All settings and waveforms can be saved to media, waveforms can be saved as binary, text or bmp files.

Hioki 9335 Wave Process Software HIO,9935 AUWaveform Processor software, displays, converts to CSV, calculates and prints waveforms with a pC. Review stored binary files from Hioki 8835, 8835-01, 8841 and 8842 memory recorders. Only way stored binary files can be viewed on a PC without having to re save them with memory recorder as Text files.Hioki 9305 Trigger Cord for Hioki Memory RecordersHIO,9305 AUPlug each end of cable 3.5mm. Trigger cord enables master slaving of the Hioki 8835, 8810 and 8811 memory recorders. One end connected to the trigger output socket of master recorder the other end connects to the trigger input socket of the second recorder which is the slave. Trigger pattern set up for the master and the slave recorder set just to external trigger.Hioki 4 Channel Digital Probe for use with HIO,8835HIO,9306 AUContact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders. Threshold digital >1.4V maximum input 50V. Contact closure input, 2kΩ input resistance 30V allowable input. Response time 2µs.Hioki 9320 4 Channel Contact & Digital Logic ProbeHIO,9320 AUFor HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders, 4 channels per probe, max of 4 probes per recorder. Use in conjunction with 9321 line logic probe. Threshold digital selectable 1.4V, 2.5V & 4V. Response time 500ns max. Relay dry contact detection. Max allowable input 50Vdc.

Hioki 9321 Line Logic ProbeHIO,9321 AUFour channels (insulated) per probe. Detection of 60~150Vac, 170~250Vac, 20~150Vdc & 70~250Vdc in 2 ranges. Response time slope rise 1ms, fall 3ms. Max input low range 150V rms, high range 250V rms. Max rated voltage to earth 250V rms. Connector cable 1.5m. Probe tip cable 1m.

Hioki Kit of Three 9322 High Voltage True rms InterfaceHIO,9322-KIT AUUsed with many memory recorders, eg. Hioki 8835. Operating modes 3. DC mode for waveform monitor output dc to 3MHz, ac mode detection of power surge noise 1 kHz~10MHz. Rectified true rms output of dc & ac voltages. 40Hz~100kHz response speed 200ms or less. Max voltage dc 2kV, ac 1kV CATII, ac/dc 600V CATIII, balanced differential input 1/1,000 divider.Hioki 520Mb PCMCIA Hard Disk for HIO,8835 & 8841HIO,8835-HD520 AUData can be stored as mem file which is binary, data can be replayed on recorder, txt file which is text so as data can be read using excel, bmp file so screen dump can be saved for import to word document, single or dual FFT binary file for playback on recorder. File can be saved as setting file, useful for customers who rent the memory recorder for same applications again. Transfer files to a PC and reload next time recorder is rented, saves time in use of recorders. Card can be plugged in to a pCMCIA Type III slot on a laptop, files can be stored or viewed.Hioki 9555 Current SensorHIO,9555 AUFor HIO,9278 clamp on CT. Output designed for waveform recording and depends on CT.Sandisk Compact Flash Card 512MB with PCMCIA AdaptorCOM,FLASH512Mb AUCompact Flash Card 512Mb typeI with pCMCIA Adaptor.Hioki 9278 Universal Clamp-on CTHIO,9278 AUFor use with HIO,9555. Range 0~200A, dc 100kHz, 20mmØ max jaw.Hioki 9132 Clip-on ac Current TransducerHIO,9132 AU/NZRanges 20~1kA fs. Short term overload capability 2kA. Output 0.2Vac. For use with Hioki 8800 series recorders, for current waveform recording.Hioki 9018-10 500A ac Clamp-On TransducerHIO,9018-10 AUSelectable ranges 10~500A. Output voltage 200mVac fs per range selected. Up to 3kHz frequency response. bNC connection.Hioki 3270 Sensor with 150A ac/dc Clamp-On TransducerHIO,3270-9276 AUFrequency bandwidth dc to 1MHz, rated output 1.5V for fs of range. Clamp 20mmØ. Suitable to view waveforms with memory recorders.Hioki 9555 Signal Conditioner with 9278 200A ac/dc Clamp-On TransducerHIO,9555-9278 AUFrequency bandwidth dc to 100kHz, rated output 2V for fs of range. Clamp 20mmØ. Suitable to view waveforms with memory recorders.Hioki 9304 Input Attenuator for 8800 Series RecordersHIO,9304 AU/NZMax input 600Vdc/ac peak.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 75

DATA

ACQ

UISI

TION

& R

ECOR

DING

Page 86: 2007 Rentalsolutionsguide-Aunz Low

Teac 16 Channel DAT Instrumentation RecorderTEA,RD145T AUSixteen channel DAT instrumentation/data tape recorder. 4ch~20kHz, 8ch-10kHz, 16ch~5kHz, ac/dc operation. Ch 1 can be selected for analogue or 14-bit digital. Data recorded at slow speeds can be played back at double speed. Input ranges 0.5, 2, 5 & 20Vp impedance 100kΩ unbalanced output ranges 2~5Vp variable impedance 75Ω unbalanced. AC or 11~30V dc operation.

tape recOrderS

HP 7440A 8 Pen Plotter Hp,7440A MYMedia sizes. 210 x 297mm (ISO A4) 8.5 x 11in (ANSI A). Regular plotter paper,glossy presentation paper, fast-dry overhead transparency film. 8 fiber-tip pens, automatic pen changing & capping. Max plotting area: Y-axis 191mm (7.5in) for A & A4 size paper, x-axis 257mm (10.1in) for A size paper. Resolution: addressable step size: 0.025mm (0.001 in). pen Velocity: pen up 52 cm/s (20 in/s). pen down max 40 cm/s (16 in/s), programmable 1 to 40 cm/s in 1 cm/s increments. Acceleration: approx 1.2 g’s. Interface Options: RS-232-C/CCITT V.24 Asynchronous serial, ASCII, 60-byte buffer size.Switch selectable baud rates: 75~9600. Switch selectable parity: odd, even, or off. HpIb: Switch selectable addresses: 0~31 (31 sets listen-only mode). Size: 308(d) x 460(w) x 125(h)mm. Weight: plotter 4.1kg. power supply 1.4kg.

plOtter printer

Yokogawa 3057-22 2 Pen Portable RecorderYEW,3057-22 AU/NZTwelve input ranges 10mV~50V fs, 150mm x 15m Z fold or roll chart, speeds 20mm/h~600mm/min. Accuracy 0.5%. power 240/50Hz, rechargeable NiCad battery or 12Vdc external. Yokogawa 3712-31 3 Pen Vertical Chart RecorderYEW,3712-31 AUInput ranges dc voltage 10mV~200V fs. Thermocouples including type T & K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory card optional.Yokogawa 3712-41 4 Pen Vertical Chart RecorderYEW,3712-41 AUInput ranges: dc voltage 10mV~200V fs. Thermocouples including type T & K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory card optional.Yokogawa 3750 10 Channel Multipoint RecorderYEW,3750 AUTen channel hybrid recorder. Input ranges dc 20mV~20V, thermocouple, RTD. Scans 10 channels in 2s. AC mains operation.

Yokogawa 3750-DC 20 Channel Hybrid RecorderYEW,3750-DC AUInput ranges dc 20mV~50V, thermocouple & RTD. Scans 20 channels in 2s. Operates from 10~32V external dc. RS232C interface option fitted. Yokogawa 3760 30 Channel RecorderYEW,3760 AUAnalogue and digital printout. Ten colour with channel identification number. Scans in 2s. Chart speeds 1~1500mm/h. Inputs dc (20mV~50V range), thermocouple (R, S, b, K, E, J, T, L, U, N, W, Kp) & RTD. Memory card reader. Memory card included with several typical set-ups.Yokogawa DR130 Hybrid 20 Channel Recorder FDDYEW,DR130 AUIncludes 3.5” FDD. Input unbalanced floating 20mV~50Vdc, TC, RTD and contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width 150mm. Data can be saved to 500k of internal RAM either directly or due to alarm conditions. The saved data can be copied to a 3.5” FDD file suitable for inclusion in standard spreadsheet programmes.Yokogawa 512K Memory Card for Yokogawa RecordersYEW,MEM512 AUMemory card 512k. For YEW,3750, YEW,3760, YEW,3712-31 YEW,3712-41 and YEW,3701-85 recorders.

Strip chart recOrderS

Tech-Rentals CT Terminations for Hioki 8710, etcTR,CT-5 AUTermination box for 5A output current transformers. For use mainly with HIO,8710. Comprises quantity 3 shunts 0.04Ω. Output 0.2V @ 5A. Use with DRA,TR2015’s.Hioki 8206 2 Channel Voltage & Current ac Chart RecorderHIO,8206 AUThe chart records a true rms. Equivalent reading. AC voltage channel, 3 ranges 50~140V, 100~280V & 250~600V. AC current channel, 0~10, 0~20, 0~50, 0~100, 0~200 & 0~500. Chart speeds 600mm/h~20mm/h. Note the supplied 9651 clamp-on current probe will measure max 46mmØ conductor. Frequency range of the clamp 40Hz~1kHz.

Hioki 8710 3 Channel ac/dc RecorderHIO,8710 AU/NZIntended mainly for recording ac line voltage and current. Data is recorded graphically and printed. Input voltage ranges 70~750V rms ac in 4 ranges with optimised scale, 0.05~7.5V dc in 5 ranges. AC current ranges using 9008 and 9132 clamp-on probes 10~1000A. Uses type 9221 thermal paper 110mm x 30m. The recorder is suitable for voltage measurements from pAM thyristor inverters but not all voltage levels with PWM inverters. Chart speed up to 30 div/min (1div is 9mm). Response time 0.6s.

vOltage current recOrderS

76

DATA ACQUISITION & RECORDING

Page 87: 2007 Rentalsolutionsguide-Aunz Low

preSSure & humidity tranSducerS

Druck PTX1400-25 25Bar Pressure Transducer 4-20mADRU,pTx1400-25 AUpressure transducer, 4~20mA output, 0~25 bar (360psi) input. Requires 9~28VDC, supplied with 12V, 500mA power pack.

Druck 580 PSI 40Bar Pressure Transducer 4~20mADRU,pTx1400-40 AURequires 9~36Vdc, supplied with 12V plug pack.

Druck PTX 1400 600Bar/9,000 PSI Pressure TransducerDRU,pTx1400-600 AUOutput 4~20mA. Requires 9~32Vdc, supplied with 12V plug pack.Druck PTX1400 400Bar/6,000 PSI Pressure TransducerDRU,pTx1400-400 AUOutput 4~20mA. Requires 9~36Vdc, supplied with 12V plug pack.Druck PTX1400 4Bar/60PSI Pressure TransducerDRU,pTx1400-4 AUOutput 4~20mA. Requires 9~36Vdc. Supplied with 12V plug pack. pressure input connector G ¼” female.Endress & Hauser 1~3Bar TransducerE&H,pMC-1~3bAR NZpressure transducer with flush face diaphram. Accuracy: 0.5% of FS. Minimum vacuum 10mbar. Operating temp -25~70ºC. Response time 90% of FS in 20ms. Output: 4~20mA. pressure connection: ½”bSp.Endress & Hauser 1Bar TransducerE&H,pMp-1bAR NZpresssure transducer with flushable diaphragm. Accuracy: 0.5% of FS. Operating temp -25~70ºC. Response time is 90% of FS in 20ms. Output: 4~20 mA. pressure connection: ½”bSp.

Model Type AnalogOut

Pressure (Bar) Differential Humidity

(%) NATA Operating Temperature(°C) Vacuum

ASH,1000

Pressure

4~20mA

1,000DRU,pTx1400-4 4DRU,pTx1400-25 25DRU,pTx1400-40 40

DRU,pTx1400-400 400DRU,pTx1400-600 600

FLU,pV350 42Yes

FLU,pV350-NATA 0~1V 24 YesGEM,2200bGb2501A3UA

4~20mA25

GEM,2200bGC1001A3UA 100

KUL,HEM375-5000 High temp pressure 0~100mV 345 <270

ROT,HTO45R001V Temp & humidity 0~1V 25~90 5~50SHA,p1041-10000

Pressure

0~100mV 715SHA,p1241-500

0~5V

35SHA,p1241-5000 357

SHA,p1241-10000 690SHA,p3061-4D 280mBar Yes

SHA,p53363-500 34.5TRA,8204-ID-20A 4~20mA 1 YesTRA,8891-4-10V 0~10V 4TRA,8891-4-20A 4~20mA 4VAI,HMp-135Y Temp & humidity

0~5V0~100 %

VAI,HMp-235Y Temp & humidity 0~100 %VEG,bAR20

Pressure 4~20mA

1E&H,pMC-1-3bAR 1~+3

-25~70

YesE&H,pM-1bAR 1

E&H,pMp-4bAR 4E&H,pMp-40bAR 40

E&H,pMp-100bAR 100JUM,1030-0-10bAR 10

-40~85JUM,40bAR 40

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 77

PHYS

ICAL

MEA

SURE

MEN

T

Page 88: 2007 Rentalsolutionsguide-Aunz Low

Digiroll Plus Measuring Wheel & SurveyingDIG,pLUS AUMeasuring wheel. For linear measurement and, area and volume calculation of construction sites and buildings, etc.Leica Disto Pro Laser Distance MeasurementLEI,DISTOpRO AU/NZTypical accuracy ±1.5mm. Will average over 8 measurements for greater accuracy. Built in function for height measurement and enclosed angles,etc. Memory can be divided into groups, e.g. 200 groups with 5 measurements. Includes PC interface and software, telescope to help find dot in daylight and bubble level to enable horizontal measurement.Mitutoyo 500-172 Digimatic CaliperMIT,500-172 AURange 0~200mm (0~8”), resolution 0.01mm (.0005”). Absolute measurement, LCD display. Temperature operating range 0~40OC, storage temperature -10~60OC. button settings ON/OFF, inch/mm. Origin, zero/AbS.

Mitutoyo Absolute Digimatic Height Gauge CaliperMIT,570-314 AUDigital height gauge for measurement of height of small components/parts. Functions, origin (absolute origin) setting, AbS (absolute) measurement, INC (incremental) measurement, hold. Measurement range 24”/600mm, resolution 0.0005”/0.01mm, error ±0.0020”/0.05mm, display 6 digit LCD.

Phantom 53550 Radar Gun kph, with Case and Tuning ForkpHA,53550 AUprofessional doppler K band (24.150GHz) stationary radar gun. Fast action, pull the trigger and the speed display appears instantly. Unit is invisible to all radar detectors. power requirements 10.5~16.5Vdc, 13.5Vdc nominal, 1.5A max, external source, connection via 6’ coiled power cord with fused lighter plug. Operating environment -20~60ºC, 90%RH @ 37ºC (non-condensing). Accuracy ±0.17kph. Accuracy verification tuning fork (K-band), internal 90kph. Speed range 17~332kph.

Jenoptik LEM300-GEO Laser Range Finder & Speed GunJEN,LEM300-GEO AUIncludes precision inclinometer and compass. Measures up to 300m horizontal or sloping distances. Distance measurements updated at 50Hz so accelerations can be analysed via RS232 interface. Overall accuracy ±10cm. Rechargeable batteries.Hilti PR50 Rotating Laser LevelHIL,pR50 AUFor facade installations, suspended ceilings, excavations, etc. PR50 is a self leveling rotating laser. System includes tripod and 2 styles of sight, the first make on audible alarm when the laser is detected, and the second when detected the system oscillates on to provide good definition of the laser in high ambient light conditions. Accuracy ±0.7mm in 10m horizontal, ±0.9mm in 10m vertical. Laser range 30m or more with beam catcher, 150m or more with laser detector.Hilti PM10 Multi Directional LaserHIL,pM10 AUTriple laser alignment system. Instrument produces 3 visible lasers each at 90O. Supplied with contractors kit including clamps, magnetic bracket, targets in case. Accuracy ±3mm in 10m, self-leveling from ±4O to horizontal.

diStance meaSurement & Surveying

tachOmeterS/StrObOScOpeS

>NEW Monarch Palmstrobe Compact Size Portable Stroboscope

MON,pALMSTRObE AUCompact size portable stroboscope, flash rate from 100~12,500FpM, 6 digit alphanumeric backlit LCD. Tachometer range 5~250,000RpM (only with external sensor connected, not included). External sensor input TTL only. Supplied with 2 x removeable rechargeable battery packs, charger and transit case.

>NEW Monarch PLT200-KIT Digital Contact/Non Contact Tacho

MON,pLT200-KIT AUHand held digital contact/non contact tacho kit. Ranges optical/non contact 5~200,000 RpM, contact 0.5~20,000 RpM. Display 5 digits, 5 alpha numeric LCD. Non contact operating range 90cm, tripod mounting. Direct contact tips and contact wheel supplied. programmable for IpM, FT/M, YpM, cm/M, m/M, RpM, RpS, RpH and Totaliser up to 200,000. Output TTL pulse.

78

PHYSICAL MEASUREM

ENT

Page 89: 2007 Rentalsolutionsguide-Aunz Low

Monarch Phaser Strobe Battery OperatedMON,pHASER AUphaser-stroboscope includes optical and magnetic pickup. Operates from internal re-chargable batteries or mains. Auto step mode provides slow motion appearance for high speed repetitive events. Stores and recalls last 3 full settings in memory. Specifications 30~30,000f/min or 0.5~533.33f/s. Accuracy ±0.01%. Flash rate external triggering 30~9,999.9f/min, 0.5~533.33f/s, 10,000~32,500f/min. phase delay facility.

Hioki 3404 Optical/Contact TachometerHIO,3404 AU/NZAutoranging 4 digit display. Ranges in RpM mode 30~99.9, 1,000~9,999 & 1,000~9999 x 10. Ranges in RpS mode 0.5~99.99, 100~999.9 & 1,000~1,600. Analogue output 1mV/10RpM or 1mV/100RpM, accuracy 4%. Tripod mounting. Internal battery or external ac operation. Contact adaptor included with cone and peripheral ring.

tachOmeterS/StrObOScOpeS

endOScOpeS

Model Type Diameter mm Length - Metre ArticulationFIb,MTFS15-1000

Fibreoptic endoscope

1.5 1 NoneMOR,MSGI-1350

81.3

Semi rigidMOR,MSpI-3000 3MAC,Fb5-1400A 4.3 1.25 2 way

OLY,IF8C5-30 8 34 wayOLY,IF11D4-20 11

2OLY,IV6C6-20-ZOOM

Video endoscope

6OLY,IV6C5-20 51 2 wayOLY,IV8C6-35 6 3.5 4 wayOLY,IV8D3-20 8.4 2 4 wayOLY,IpLEx-Mx 6 3 4 way

OLY,CYF-3Fibrescope endoscope

6 0.37 2 waySIL,PF136 9 1.32 Semi rigid

AQU,SNAKEEYE Colour video flexible cable 30 9.1 NoneWHO,VIpER CAMERA KIT Option for Minispring 51 - Rotating head

WOH,MINISPRING Colour video rigid push rod 22 20 NoneWOH,VIS220

Colour video flexible cable26 19.5 None

WOH,VIS2000 5130

Rotating headRAD,GATORCAM-25-30

B&W videoscope and recorder25 NoneRAD,GATORCAM-25-60 60

pEA,FLExI-CAM Colour video pipeline inspection system 15HEI,TECHNO-6x320

Borescope6 320mm

OLY,G100-034-090 55 10 340mmSYK,4-30-ARTHRO 4 180mm

DYO,750 Camera and video processor

Pearpoint Flexi-Cam Pipeline Inspection System pEA,FLExI-CAM AU/NZCompact colour video 25mm colour camera with 3lux sensitivity, (light source white LED’s) on 15m of fully retracting flexi-rod. Flexi-cam navigates multiple 90O bends in 32mm pipes and images are displayed on the internal colour TFT screen. Images can be recorded to an external video recorder (not supplied). System operates from internal fully rechargeable batteries which provide up to 5h of continuous use when fully charged. Hand-held portability. Fully waterproof, manually set focus camera. Inspects pipes 25~100mm.Radiodetection Gatorcam-25-30 Drain Video Inspection System RAD,GATORCAM-25-30 AUMonochrome video scope 30m x 25mmØ. Kit includes video display and VCR combination and 33kHz sonde capability so the camera location can be determined using the RAD,RD400pxL. Has fixtures to centre the camera in larger diameter pipes. Camera includes variable illumination. Length of cable extended is displayed and comments can be added to the image.

Radiodetection Gatorcam-25-60 Drain Video Inspection SystemRAD,GATORCAM-25-60 AUMonochrome video scope 60m x 25mmØ. Kit includes video display and VCR combination and 33kHz sonde capability so the camera location can be determined using the RAD,RD400pxL. Has fixtures to center the camera in larger diameter pipes. Camera includes variable illumination. Length of cable extended is displayed and comments can be added to the image.Wohler Minispring 15m x 22mm B&W Inspection CameraWOH,MINISpRING AUSemi rigid push rod 20m long with 22mm colour camera. Waterproof to 15m. Kit includes a small battery operated display with a video output. Large display and recorder option.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 79

PHYS

ICAL

MEA

SURE

MEN

T

Page 90: 2007 Rentalsolutionsguide-Aunz Low

>NEW Wohler VIS 220 Visual Inspection System for Pipes and Drains

WOH,VIS220 Compact colour video pipeline inspection system, 26mm colour camera with bright white LED’s on 19.5m of flexible push rod with metric marking. Camera sensitivity 3 Lux, lens f=2.5mm, F=2.0, view angle 120º, waterproof to 30m water depth. Suitable for insertion in pipes and spaces from 40 to 150mm diameter. The system is supplied with 2 battery packs and an AC charger/power pack, each battery pack lasts approx 1.5h. Supplied with 5.6” TFT display with extension cable, video output suitable for video recorder (not supplied).

Wohler VIS2000 30m x 51mm Steerable Color CameraWOH,VIS2000 AUFor inspection of ventilation ducts, chimneys, chambers and flue gas systems, etc. Kit consists of color display with joy stick to control the camera. Flexible 30m cable on a reel, with non-waterproof, splash resistant, 51mmØ colour camera with illumination. Accessories included to assist for chimney inspection: a fixture to allow the camera to be lowered down chimneys, a guide to centre the camera inside chimney-like spaces and a holder to allow the camera to look up rather than down.Wohler Viper Camera Kit for Minispring WOH,VIpER CAMERA KIT AUOptional camera with remote control movement of camera for WOH,MINISPRING. Cannot be used on its own.Aqua Snakeeye 9m x 25mm Video Inspection AQU,SNAKEEYE AU/MYFor remote inspection work. Very light and compact. Includes a 127mm TFT-LCD display & 30mmØ camera including illumination. Various adaptors are supplied for mounting the camera to, your hand, 457mm with 90O articulation arm or 9.1m extension cable.Machida FB5-1400A 4.3mmØ x 1.25m EndoscopeMAC,Fb5-1400A AUEnd section steerable in 2 axis, 120O. Instrument is fragile due to the narrow diameter and lack of a thick protective sheath. Light source included.Moritex MSGI-1350 1.35m x 8mm Semirigid EndoscopeMOR,MSGI-1350 AUMOR,MSGS-1350 NZSize 8mmØ x 1.35m long. Kit includes a 90O side view adaptor, when used diameter is then 10.1mm. Includes battery light source. View angle 27O. Focal length 10mm~infinity. Working temperature 0~60OC. Image 13,000 pixel. Optional video camera available.Olympus CYF-3 6mm Diameter 37cm long FiberscopeOLY,CYF-3 AUFibrescope 6mm diameter, 37cm long fibrescope, articulation 190 deg up and 90 deg down. Includes CLK-4 light source. Non metal insertion tube, synthetic rubber.

Moritex PalmScope Video Capture Device for JPEG & Movie Clip Recorder Inspection MOR,pALMSCOpE AUDigital Video Recorder, image capture and storage. Used in conjunction with an endoscope, borescope or videoscope the PalmScope is an alternative to a VCR for onsite inspection applications. Unit records, store video sequences and full frame resolution jpeg images on supplied 512Mb Compact Flash Card. View images on built in 6.4” TFT LCD screen. Stores jpeg still images and or mjpeg movie clips. Signal input video NTSC or pAL, auto-selecting.

Moritex 2C Mount AdaptorMOR,2CMOUNT AU2C mount adaptor.Camera Mount for Moritex Eye PieceMOR,CAM-MOUNT AUMount to allow the connection of a standard camera to a Moritex endoscope. Adaptors connect to where you would normally add a filter to a camera. Ring sizes which this can adapt to include 52mm, 49mm ,46mm & 37mm. Sony Mavica (SNY,MAVICA-FD95) can be used, or check the size of the filter which is used on the camera.

>NEW Silverado PF136 Portable Fibrescope

SIL,pF136 AUportable fibrescope, 9mm diameter, 1320mm working length, gooseneck semi rigid insertion tube, supplied with 90º side view adaptor mirror. built in battery compartment for LED light source. Viewing direction 0°, viewing angle 45º, Depth of view 30mm to 150mm. Side view adaptor viewing direction 90º, viewing angle 45º, depth of view 30mm to 150mm, tip diameter 10mm.

endOScOpeS

80

PHYSICAL MEASUREM

ENT

Page 91: 2007 Rentalsolutionsguide-Aunz Low

Olympus IPLEX- MX Portable Industrial Videoscope OLY,IpLEx-Mx AUIpLEx Mx battery powered industrial videoscope, lightweight just 4.5kg out of transit case. 6mmØ, 3m length tungsten insertion tube, articulation 4 way Up/DOWN/LEFT/RIGHT 120O. Field of view 120O, depth of field 18mm to infinity, illumination method LED. Brightness adjustment 11 step, long exposure up to 1sec, zoom electronic linear up to 3x, built in 5.6inch TFT full colour display, image recording built in, image format JPEG, over 230 images with supplied CF card. powered from either rechargable Li-ion 2x battery packs (4 hours) or AC adaptor.

Olympus Endoscope/Recorder TV Camera Inspection OLY,VIDEO AUVideo camera, monitor, VCR and adaptor kit to suit Olympus endoscopes. Two mount adaptor.Olympus IF8C5-30 8mm x 3m Long EndoscopeOLY,IF8C5-30 AULength 3.25m (effective 3m), 8mmØ, angulation range, 4 direction, up/down 120O, right/left 100O, light guide cable length 2m. Optical adaptor fitted AT60DFF, field of view 60O, forward viewing, depth of field 20mm~infinity. Outer diameter 8.4mm. Operating temperature in air -10~80OC, in water 10~30OC. Operating pressure water 1,013~1,317hpa (1~1.3atm), air 1,013hpa (1-1.3atm). Fluid resistance insertion tube withstands machine oil, light oil. Only insertion tube can be placed in water. Supplied with eye piece and light source.Olympus IF11D4-20 11.3mm x 2m Length EndoscopeOLY,IF11D4-20 AUWorking length 1.7m. Large sharp images with adjustable focus regardless of distance. Depth of field of view 8mm~infinity, field of view 78O, direction of view forward. Easy up/ down 120O, right/left 100O angulation of bending section which can be locked at any angle. Includes Olympus ILK-5 light source, halogen lamp. Operating temperature insertion tube including optical adaptor, in air -10~80OC, in water 10~30OC.Olympus IV6C6-20-ZOOM Videoscope 6mm x 2m LongOLY,IV6C6-20-ZOOM AUFitted with AT120D/NF optical adaptor, field of view 120O, direction of view forward, depth of field 5mm~infinity. Angulation 4 way, 150O up/down & left/right, heavy duty tungsten insertion braid tube. Operating temperature for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance for insertion tube - withstand machine oil, light oil and 5% salt water. Supplied with IV-6A video control unit, which has zooming and virtual scrolling (panning) with moving images function, extended exposure time for darker areas, built in image enhancement and freeze frame. ILH-2b light source, panasonic 7” LCD colour monitor mounted on extension arm all fitted to transit case for ease of use. Video VHS recorder also included in package.

Olympus IV8D3-20 8.4mmØ, 2m Long VideoscopeOLY,IV8D3-20 AUIndustrial flexible videoscope, 2m long, 8.4mmØ, distal tip non removeable, field of view 100O, depth of field 7-122mm (fixed focal point). Angulation 4 way, 120O Up/DOWN, 100O RIGHT /LEFT. Heavy duty tungsten insertion braid tube. Operating temperature for insertion tube in air 0~50OC, in water 10~30 OC. Liquid resistance for insertion tube - withstand machine oil, light oil and 5% salt water. Supplied with IV-5 video processor unit, ILK-5 light source and TV/Video VHS recorder.Olympus IV8C6-35 Videoscope 8.4mm x 3.5m LongOLY,IV8C6-35 AUFitted with AT80D/FF optical adaptor, field of view 80O, direction of view forward, depth of field 40mm to infinity. Angulation 4 way, 150O in up/down & left/right, heavy duty tungsten insertion braid tube. Operating temperature for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance for insertion tube - withstand machine oil, light oil and 5% salt water. Supplied with IV-6 video control unit, ILH-2A light source and TV/Video VHS recorder.Dyonics Model 750 Video Camera & ProcessorDYO,750 AUFor endoscopes and borescopes with british standard eye piece. TV/Video recorder not included.Heine Techno 6mm x 320mm T.05.26.302 BorescopeHEI,TECHNO-6x320 AUDirection of view 70O, with angled extension tube 120O x 120O. battery pack included, dc supply cord, battery charger and mains power pack.

Olympus G100-034 090 55 BorescopeOLY,G100-034-090 55 AUG series rigid borescope 340 mm, 10 mmØ, direction of view 90O, field of view 55O. Stainless steel insertion tube, operating temperature -20~150OC. Includes Olympus ILK-5 cold light source, Sony CCD-IRIS colour video camera, AK2-10C adaptor for Sony CCD-IRIS. View via eye piece or via video connection to TV.

Stryker Borescope 4 mmx 180 mm Long, 27.5O ViewSYK,4-30-ARTHRO AUSupplied with Quantum 4,000 light source, 597 camera head and video processing unit. Very high quality system.Fibrescope MTFS15-1000 1.5mm x 1m EndoscopeFIb,MTFS15-1000 AUWorking length 1.5mmØ x 1,000mm. Includes light source. Operating temperature -20~60OC at atmospheric pressure.

endOScOpeS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 81

PHYS

ICAL

MEA

SURE

MEN

T

Page 92: 2007 Rentalsolutionsguide-Aunz Low

Olympus CH2 Binocular MicroscopeOLY,CH2 AUMagnification of eyepiece x 10. Magnification of objective lens x4, x10, x40, x100 (oil type) to give a max magnification of 1,000. In-built light source.Proscope SCA-12770 Video Microscope KitpRO,SCA-12770 AUHand-held USb video microscope complete kit. Includes 200x, 100x, 50x, 1~10x interchangeable lenses, C Mount adaptor, stand and carry case. Connects to a pC via USb interface. Software allows snap shot still images and real time movie files to be saved. Resolution is 640 x 480 pixels.

Chroma 7310 Video MicroscopeCHR,7310 AUHigh resolution colour camera x40 & x200 magnification. Includes illumination, auto gain control, auto white balance adjustment, etc. Freeze picture and compare function. Scalar VL-7EX Video MicroscopeSCA,VL-7Ex NZHandheld video microscope. View and capture images to a pC or TV/video recorder. Supplied with a x30 lens, video to USb adaptor and windows software. Optional 14” TV/video is available.Polaroid Microcam Microscope CamerapOL,MICROCAM AUInstant film camera for binocular microscopes. Simple over eyepiece fitting permits use with virtually any model.

micrOScOpeS

high Speed videORedlake Motionmeter High Speed Digital Camera RED,MOTIONMETER AU/NZUp to 1,000frames/s, selectable 50, 60, 125, 250, 500 & 1,000frame/s, exposure rates 1x, 2x, 3x, 4x, 5x, 10x & 20x the recording rate. Manual record, trigger record, adjustable pre trigger 0~100%. Storage 4,098 frames. playback rates 1,2,3,4,5,10,15,25,30,50, 60,125,250,500 & 1000frame/s. Output composite video NTSC or pAL (monochrome) also supplied with video to USb converter, flood lights and tripod.

Redlake Motionscope SR500 High Speed VideoRED,SR500 AUTriggering facilities similar to a digital oscilloscope. 2,048 frames can be captured up to 500frames/s. Shutter speeds 1/60~1/5,000s. Images can be viewed from a frame by frame basis to real time. Monochrome image. pAL video output. TTL trigger input. Use any standard oscilloscope to supply the signal. C mount interface on camera. System with C mount adaptor can be used with endoscope.Redlake 1000 Frames/Sec Motion ScopeRED,S1000 AUTriggering facilities similar to a digital oscilloscope. 4,096 frames can be captured at up to 1,000frames/sec. Images can be viewed from a frame by frame basis to real time. Shutter speeds 1/60~1/10,000s. Monochrome image 336 x 243 x 8-bit pixels. Weight 5.5kg. pAL video output. Trigger input TTL. Use any standard oscilloscope to supply the signal. Adaptor can be used with endoscope.Orion VPDC ac/dc Powered Video RecorderORI,VpDC AUpAL b/G portable video recorder includes NTSC playback on pAL TV. Two rotary heads, helical scanning system, 1 track audio.Orion 10VRKT 23cm TV with built in VCRORI,10VRKT AUAC/dc combination 10” (23cm) colour TV and video recorder. TV channels VHF, UHF, audio output power 1.2W max. VCR pAL b/G, 2 head. power 240Vac, 12Vdc. Supplied with remote control.

82

PHYSICAL MEASUREM

ENTModel Type Pressure (Bar) NATA Accuracy

bRI,1000-NATAPressure recorder

69Yes 0.5%bRI,10000-NATA 690

bRI,5000-NATA 345HOB,PRES Pressure logger 1.013 1% fs

STE,1000-NATA

Pressure gauge

69

Yes 0.5%STE,10000-NATA 690STE,5000-NATA 345TR,pRESS-NATA 100

CEC,140bARDigital gauge & logger

140No ±0.1%

CEC,30bAR 30

preSSure vacuum gaugeS/recOrderS

Page 93: 2007 Rentalsolutionsguide-Aunz Low

Tech-Rentals 4,000, 6,000 & 10,000kPa Pressure Gauges NATA CalibratedTR,pRESS-NATA AUThree gauges. Accuracy ±0.5% 4,000kpa, 6,000kpa & 10,000kpa.Bristol Babcock 1,000psi Mech Chart RecorderbRI,1000-NATA AUCircular pressure chart recorder 1,000psi. 12”Ø. Accuracy ±0.5% NATA calibrated. Fitted with 2 speed spring wound chart drive giving 7d or 24h recording. pressure connection ¼”NpT.Bristol Babcock 5,000PSI Mech Chart RecorderbRI,5000-NATA AUCircular pressure chart recorder 5,000psi. Description as aboveBristol Babcock 10,000 PSI Mech Chart RecorderbRI,10000-NATA AUCircular pressure chart recorder 10,000psi. Description as above.Stewart Buchanan 12 1,000 PSI Gauge NATASTE,1000-NATA AUStainless steel, accuracy ±0.5% NATA calibrated. pressure connection ¼”NpT.

Stewart Buchanan 12 5,000 PSI Gauge NATASTE,5000-NATA AUStainless steel, accuracy ±0.5% NATA calibrated. pressure connection ¼”NpT.Stewart Buchanan 12 10,000 PSI Gauge NATASTE,10000-NATA AUStainless steel, accuracy ±0.5% NATA calibrated. pressure connection ¼”NpT.XP2i Digital Gauge & Logger 140BarCEC,140bAR NZIntrinsically safe high accuracy temperature compensated pressure data logger with IANZ calibration certificate. Records up to 3,000 pressure measurements. Recording intervals or 1s~8h. Data download and analysis on any Windows equipped laptop or PC. Data can be saved directly into MS Excel. Internal battery powers unit up to 3m. Can be used as a reference gauge with or without a hand pump.XP2i Digital Gauge & Logger 30BarCEC,30bAR NZDescription as above.

Endress & Hauser 4Bar TransducerE&H,pMp-4bAR NZDescription as per E&H,pMp-1barEndress & Hauser 40Bar TransducerE&H,pMp-40bAR NZDescription as per E&H,pMp-1bAREndress & Hauser 100Bar TransducerE&H,pMp-100bAR NZDescription as per E&H,pMp-1bARJumo 1030 10Bar Pressure TransducerJUM,1030-0-10bAR NZOutput 4~20mA. Accuracy is 0.5%. Temperature range -40~85ºC, response time 30ms.Jumo 40Bar Pressure TransducerJUM,40bAR NZOutput 4~20mA. Accuracy 0.5%. Temperature range -40~85ºC, response time 30ms.Schaevitz P3061-4D 4PSI Differential Pressure TransducerSHA,p3061-4D AU100” water gauge, 4psi. LVDT type with built-in amplifier. Output 0~5Vdc. Operates from 10~32Vdc or ac mains.Kulite 5,000PSI High Pressure Temperature Transducer 260OCKUL,HEM375-5000 AUIncludes 10V regulated supply. Output 0.020mV/psi. Trafag 8891 4Bar/58PSI, 0~10V, Pressure TransducerTRA,8891-4-10V AUAccuracy ±0.3% FS. Overpressure 10bar (145psi). Output 0~10V. pressure connection G ¼” male. bandwidth 1kHz. Media temperature 125OC. IP65 rated. power supply 15~30V.Trafag 8891 4Bar, 58 PSI, 4~20 mA, Pressure TransducerTRA,8891-4-20A AUAccuracy ±0.3% FS. Overpressure 10bar (145psi). Output 4~20mA. pressure connection G ¼” male. bandwidth 1kHz. Media temperature 125OC. Ip65 rated. power supply 10~30V.Trafag 8204 1Bar ,14PSI, 4~20mA, Differential Pressure TransducerTRA,8204-1D-20A AUSame specification as above.

Vega Bar 20 0~1Bar Transducer with DisplayVEG,bAR20-1 AUOutput 4~20mA. LCD display and is rated Ip65. Over pressure resistant to 10bar & -1bar. Measurement accuracy 0.5%, linearity deviation 0.085%. May be set to bar, psi, kpa, mpa, mmH2O, mH2O & mbar. Output can be 4~20mA or 20~4mA. Integration time 0~10s. Density factor may be entered for mm & m, output simulation indication module has 20 segment bar graph and 4 digit display which may be scaled (has factory default reset). Supply required 12~36Vdc. Schaevitz P53363 500 PSI, 0~5V Pressure Transducer incl SnubberSHA,p53363-500 AUOutput 0~5V.Schaevitz P1241 500PSI Pressure TransducerSHA,p1241-500 AUOutput 0~5 V. port ¼”bSp (f). Operation12Vdc or mains.Fluke PV350 Vacuum/Pressure IndicatorFLU,pV350 AUCan be used with a digital multimeter (eg Metrix Mx45) to act as an indicator. Range, pressure to 600psi (4137kpa) & vacuum 0~29.22”Hg (0~76cmHg ). Results in either psi or kpa. Connector ½”NpT (m). Cable 2.4m provided. Battery powered.Fluke PV350 Vacuum/Pressure Indicator, NATA CertificateFLU,pV350-NATA AUSpecification as above but with NATA certificate.Schaevitz P1241 10,000PSI 0~5V Pressure Transducer incl SnubberSHA,p1241-10000 AUpressure transducer 10,000psi, includes snubber, 0~5V output.Ashcroft 1,000 Bar Pressure TransducerASH,1000 AURange 10~36Vdc supply. Output 4~20mA. Connection ¼”NpT (M).GEM,2200BGC001A3UA 100Bar Pressure TransducerGEM,2200bGC1001A3UA AUCan be used with a digital multimeter (eg Metrix Mx45) to act as an indicator. Transducer could be used with a chart recorder or data logger that can accept 4~20mA signal input. pressure range is 100bar (10,000Kpa or 1,450psi). Transducer has a 4~20mA output. power supply and connection leads are supplied.

preSSure & humidity tranSducerS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 83

PHYS

ICAL

MEA

SURE

MEN

TpreSSure vacuum gaugeS/recOrderS

Page 94: 2007 Rentalsolutionsguide-Aunz Low

Wyler Clinitronic 45 Inclinometer RS-232CWYL,CL45 AU/MYResolution 0.01O. Accuracy better than 30arc sec. Display inclination in all common measurements. Includes RS232 interface for remote display of inclination and also logging. Settling time <5s.

inclinOmeterS

Rotronic Temperature/Humidity Transducer for DataTaker DT600/605ROT,HTO45R001V AUHumidity range 25~90%RH 10mV/%RH accuracy 3% resolution 0.6%. Temperature range 5~50OC, 10mV/1OC accuracy 1O, rep 0.2OC. Datataker will supply around 100mA through switched supply. Response time 10s humidity, 20s temperature. Duct mount model 120mm long x 25mmØ. Supply 4.8~24Vdc draws 4mA.

Vaisala HMP 235Y 180OC Humidity ProbeVAI,HMp-235Y AUHigh temperature humidity and temperature transmitter. Sensor head operates from 0~180OC. Measurement range 0~100%RH. Accuracy of 1%RH at 20OC. Output 0~5Vdc. Other outputs easily set including 4~20mA. Operates from 15~30Vdc or ac mains.Vaisala HMP 135Y 160OC Humidity ProbeVAI,HMp-135Y AUSame specification as above but sensor head operates from 0~160OC.

preSSure & humidity tranSducerS

84

PHYSICAL MEASUREM

ENT

Houston 1850-40 Position TransducersHOU,1850-40 AU/NZLinearity 0.1% travel 40” (1m). Cable tension 280g. Max velocity 132cm/s. Output is a variable resistance arranged to provide both high level (V) and low level (mV) outputs when powered from an external source.

Unimeasure P510-40 Position TransducerUNI,p510-40 AUTravel 40” (1m). Output 0~5V or 0~10V selectable. Requires 12~30Vdc source.

pOSitiOn tranSducerS

Ametek Cadet 25 Digital Force GaugeAME,CADET-25N AURS232C interface. Range 0~25N (2.5kg), resolution 0.3N (1g), accuracy 0.5% of full scale. Deflection 1mm. Display 4 digit LCD. bi-directional with peak hold for compression & tension. NiCd operated. 1Vdc recorder output.Mecmesin AFG-1000N Digital Force GaugeMEC,AFG-1000N AURange 0~1,000N accuracy 0.1% (1 ton) 5 digit display. Sampling rate 1kHz. Overload protection and counter. Outputs analog, RS232 & Mitutoyo. Accessories, test hook, 12mmØ compression plate, 30mm & 130mm extension rods.

Mecmesin AFG-1000NALC Digital Force GaugeMEC,AFG-1000NALC AURange 0~1000N accuracy 0.1%. 5 digit back lit display. peak data sampling rate 5kHz. 120% overload warning, display invert (reverse) function, dual max, max tension & max compression plus current reading. Outputs: analogue, RS232 & Mitutoyo. Accessories: test hook, compression plate, 130mm & 30mm extension rods, rotary coupling. Mounting tapped holes x 2, M5 x 0.8 x 5.5mm deep max. Optional smart sensors can be used, such as TW60 static torque wrench.Mecmesin TW60 Torque WrenchMEC,TW60 AURange to 60Nm, optional accessory to be used with MEC,AFG-1000NALC Force Gauge. Smart interface, as soon as plugged into force gauge scaled accordingly.

Model Type Analog Out (V) RS232 Nata Range(kg) Resolution (g)AME,CADET-25N

Force gauge 0 ~ 1

2.5 12.5

MEC,AFG-1000NYes 100 100

MEC,AFG-1000NALC No

fOrce gaugeS

Page 95: 2007 Rentalsolutionsguide-Aunz Low

lOad cellS

Model Type Range (kg) Output (V)bAR,MTC-150

Load cell

68 0~5

bAR,STC-500 2300~2

bAR,STC-500NATA 230g

AIC,SG-AST-500 500 0~10

bAR,STC-4400 2,000

0~5

bAR,STC-5000 2,270

bAR,STC-10000 4,536

bAR,STC-20000 9,072

bAR,STC-25000 12,000

EMC,100KG

Tension load cell

100

EMC,200KG 200 Yes

EMC,1000KG 1000 Yes

STR,1590C Compression load cell 8,000

DIL,ED2000RCrane scale

20,000RS232/485

DIL,Ex2000 – 5K 5,000

AND,WEIGH-bEAMS Platform Scale 2,000

AND Mercury Platform Weighbeams for Pallet up to 2,000kgAND,WEIGH-bEAMS AUTotal weight capacity 2,000kg for the 2 weigh beams. Two stainless steel weigh beams supplied, length 1200l x 100w x 80hmm, weight 13kg each. Connection cable length 5m. AD4406 display supplied, RS232 output. Transit case with handles and wheels for ease of handling.

Barlo MTC-150 150lb/68kg Load CellbAR,MTC-150 AURange 68kg compression and tension. Complete with interface operating from 12Vdc or ac mains giving 0~5Vdc output.AIC SG-AST-500 500kg S Type Load Cell with Panel DisplayAIC,SG-AST-500 AUTension and compression 500kg. Nominal output 2mV/V, max excitation 15Vdc, Ip67 protection, safe load 125%, compensated temperature range -10~40OC. Thread M12 x 1.75p. Supplied with 2 x detachable rod end bearings, pM4 -SG-dc-5E load cell panel meter, power 12~48V dc, ac adaptor supplied, output 0~10V. panel indication in kg.Barlo STC-500 500lb/230kg Load CellbAR,STC-500 AUComplete with conditioning electronics. Output 0~2V. Uses ½”UNF thread.Barlo STC-500 500lb/230kg Load Cell NATA CalibratedbAR,STC-500NATA AUSpecification as above but with NATA calibration. This load cell is suitable for tension only.

Barlo STC-4000 4,400lb/2,000kg Load CellbAR,STC-4400 AURange 2,000kg compression and tension. Complete with series interface operating from 12Vdc or ac mains. Output 0~5Vdc. Cable to digital display unit 6m. Uses ¾”UNF thread.Barlo STC-5000 5,000lb/2,270 kg Load CellbAR,STC-5000 AURange 2,270kg compression and tension. Interface operates from 12Vdc or ac mains. Output 0~5Vdc. Display resolution 1kg.Barlo STC-10000 10,000lbs/5,000kg Load CellbAR,STC-10000 AURange 4,536kg compression and tension. Interface operates from 12Vdc or ac mains. Output 0~5Vdc.Barlo STC-20000 20,000lb/10,000kg Load CellbAR,STC-20000 AURange 9,072kg compression and tension. Interface operates from 12Vdc or ac mains. Output 0~5Vdc.

Barlo 25,000 lb/12,000 kg Load Cell and DisplaybAR,STC-25000 AUComplete with 10m cable. Includes D shackles, analog and RS232 output. 12,000kg load capacity.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 85

PHYS

ICAL

MEA

SURE

MEN

T

Page 96: 2007 Rentalsolutionsguide-Aunz Low

EMC 100kg Tension Load CellEMC,100KG NZ100kg S type tension load cell with digital indicator. Accuracy ±0.3% of reading. Operating temperature range -18~65ºC. Safe overload is 150% of rated capacity. Supplied with threaded eye hooks. Analogue output.EMC 200kg Tension Load CellEMC,200KG NZ200kg S type tension load cell with digital indicator. Specification as per EMC,100kgEMC 1000kg Tension Load CellEMC,1000KG NZ1,000kg S type tension load cell with digital indicator. Specification as per EMC,100kgEMC Load Cell ConditionerEMC.L/CELL-COND NZLoad cell conditioning unit with a recorder output. AC mains powered.Strainstall 8,000kg Compression Load CellSTR,1590C NZ8,000 kg compression pedestal load cell.Dillon ED2000 Crane Scale 20,000kg with Radio Remote ControlDIL,ED2000R AUComplete with shackles and radio remote control unit. Range 20,000kg. Accuracy 0.1%, i.e. 20kg uncertainty. Units of measure kg, kt, mt, & lb. Resolution 5kg. proof load 200% of rated load. Displays gross and net force. RS232 and RS485 data outputs. Continuous measurement and peak hold.

Dillion ED2000 5,000 kg Crane ScaleDIL,ED2000-5K AUComplete with shackles. Range 5,000kg. Accuracy 0.1%. Resolution 1kg. i.e. 20kg uncertainty. Units of measure: kg, kt, mt, & lb. proof load 200% of rated load. Displays gross and net force. Continuous measurement and peak hold.

UWE 5,000kg Digital Crane ScaleUWE,CS-5T NZbattery powered digital crane scale complete with hook & shackle. Load capacity 40kg~5,000kg, resolution 2, accuracy is ±10kg. built in large LED display, wireless remote control, and charger.

lOad cellS

>NEW Anton Paar DMA 35N Portable Density Meter

pAA,DMA35NPortable density, specific gravity & concentration meter. Measuring range 0.000~1.999g/cc and 0.0~40.0ºC. built-in pipette style pump for sample aspiration, with port for optional syringe-filling. Display of specific gravity, ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage of up to 1024 results, with recall, and infrared port for RS232 download to serial printer or PC. Wetted parts glass and PTFE. Battery powered.

Hydramotion Viscolite 700 Portable ViscometerHYL,V700S-21 AUAdvanced portable viscometer with stainless-steel probe. Operating range 0.1~10,000mpaps (cp) with integral temperature correction -40~150ºC. probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm (viscosity/temperature). Acetal polymer probe base for handheld or clamped operation, with coiled-cable connection to meter unit with 5 digit display. Battery powered.

materialS teSting

86

PHYSICAL MEASUREM

ENT

Page 97: 2007 Rentalsolutionsguide-Aunz Low

Model Type RS232 Range (g) Resolution (g)AND,GR-202 Analytical balance Yes 210 or 42 0.1mg or 0.01mgAND,FC-10K

Counting scale

10kg 0.02AND,HF-300G Yes 310 0.001AND,Hp-40KA 20kg 0.5MET,PB8000I 8.1kg 100mgISH,CCS3025 25kg 5mgOHA,Exp4100

Yes

4,100 0.01AND,AD4714

Moisture balance70 0.01

AND,Mx50 51 0.001AND,FG-150Kb Platform scale 150kg 0.05

AND,HL400 Scale 400 0.1AND,FS-15KA

Weighing Scales15kg 1

MET,15KG 15kgMET,60KG 60kg

AND,WEIGHbEAMS Platform Scale Yes 2000 0.05

A&D Mercury Platform Weighbeams for Pallet up to 2000kgAND,WEIGH-bEAMS AUFor pallet weighing. Total weight capacity 2000kg for the two weigh beams. Two stainless steel weigh beams supplied, length 1200mm, width 100mm, height approximate 80mm, weight of each beam 13kg. Connection cable length 5 metres. AD4406 display supplied, RS232 output. Transit case with handles and wheels for ease of handling.

A&D Mercury AD4714 Moisture Balance ScalesAND,AD4714 AUMoisture content to 0.1%. Sample weight 5~70g. Includes timer and RS232 interface. Weight readability 0.01g. Max temperature 200ºC, heater 185W infrared.Ohaus EXP4100 4100g Balance and Counting ScaleOHA,Exp4100 AUCapacity 4.1kg. Display resolution 0.01g. Multi-unit display. Repeatability 0.005g. RS232 interface.A&D Mercury FS-15kg Weighing ScalesAND,FS-15KA AUHigh resolution 15kg scales. Display resolution 1g. AC & NiCad battery operation.A&D Mercury FC-10K Counting ScalesAND,FC-10K AUHigh resolution 10kg scales with sample counting facility. Display resolution 1g, internal resolution 0.02g. Sample size user selectable – normally 10 pieces. Max count size up to 999,999. AC & NiCd battery operation.A&D HP-40KA 40kg Counting ScaleAND,Hp-40KA AUCapacity 40kg with 0.5g resolution. Can be used to determine battery weight change with charge, etc.A&D Mercury FG-150KB 150kg ScalesAND,FG-150Kb AUCapacity 150kg, 0.05 resolution. Includes RS232 port. National Standards Commission approved (NSC).

A&D HF-300G Mercury 300g Counting ScalesAND,HF-300G AUScales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port. Includes counting software. Can be used as counting scales. Ishida 25kg Digital Counting ScalesISH,CCS3025 NZMaximum capacity 25kg, resolution 5g. Features: unit weight, sample weight and tare.A&D Mercury MX50 Moisture AnalyserAND,Mx50 AU Maximum sample weight capacity 51g, resolution 0.001g, moisture content accuracy over 1g, 0.1%, over 5g, 0.02%. ,Halogen lamp heater, 400W max. Drying temperature 50~200OC. Measurement programs 20 sets, measurement mode moisture content, wet or dry, dry content, ratio, weight. Heating mode standard, automatic, quick, timer, manual. Display large VFD, interface RS232C, CD-ROM software supplied. pan sample size diameter 85mm.

Mettler PB8001 8kg Counting ScalesMET,pb8001 AUCapacity 8.1kg with 0.1g readability. Sample size selectable 5~100. Can do taring, percent and dynamic weighing. Powered by battery eliminator.A&D Mercury HL400 Scale 400g x 0.1gAND,HL400 AUbattery operated balance, range 400g, resolution 0.1gA&D GR-202 Mercury Dual Range Analytical BalanceAND,GR-202 AUTwo-layer construction, splash-proof keyboard and front operating door-lever. Range 210g x 0.1mg & 42g x 0.01mg. One-touch calibration and automatic self-calibration outside preset temperature limits. Functions include multiple weighing units, counting or %, data memory, adjustable environment setting and GLP management. Bidirectional RS232C standard. Low-voltage operation with ac adaptor.Mettler 15kg Weighing ScalesMET,15KG MY

Mettler 60kg Weighing ScalesMET,60KG MY

ScaleS & balanceS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 87

PHYS

ICAL

MEA

SURE

MEN

T

Page 98: 2007 Rentalsolutionsguide-Aunz Low

vibratiOn & alignment analySiS

Model Type Application FeaturesFrequency

Range(Hz)

Max Acceleration (G)

ARL,EL-235 Ground vibration loggerMonitoring vibration for pile driving and general construction vibration

Logging outdoors enclosure

BK,2635 Accelerometer charge ampbK,4230 Sound level meter calibrator NATAbK,4333

Accelerometer 2~10,000

10,000bK,43432~12,000

BK,8301bK,4370

Single axis accelerometer

0.2~5,4kHz 2,000bK,4371 0.2~12.7kHz 20,000

pCb,300A20 Low G will operate down to DC dc~300 20

TEx,ATM Blast logger and ground vibration logger

Explosion and general construction vibration

monitoring

Logging outdoor enclosure, tri-axial

geophones4.5~500

bLA,UMx-SM-6 Blast logger Explosion monitoring Tri-axial geophones

CSI,ULTRASpEC Balancing system & vibration analysis Balancing & spectral analysis

LAb,LW-140-141 Vibration table (requires frequency source)

Shake source for testing purposes

pRU,ROTOptical machinery shaft alignment Allow for the alignment of non

rotating shafts

Includes thermal growth analysis

pRU,ROT-ULTRA

RIO,Cp-10 Printer For use with RIO,VA-10

RIO,VA-10

Vibration analyser Machinery condition monitoring

Hand held accelerometer

RIO,VA-11Hand held & magnetic

accelerometerPC memory card

capability

RIO,VM82 Vibration meter Machinery and monitoring Magnetic accelerometer

SVA,912A & SVA,SV06A Tri-axial accelerometer & analyser Whole body vibration measurement

Includes whoopee cushion +/-50

TIN,SHOCKSET Single axis shock logger Shipping and packaging analysis Logging capability

PIE,308B Accelerometer with amp 1~3kHz

MAD,SHOCK101 Tri-axial bump LoggerLogging vibration for

transportation i.e. trucks, containers

Tri-axial transportation logging

Pruftechnik Rotalign Ultra Laser Shaft AlighmentpRU,ROT-ULTRA AULaser based rotating shaft alignment system. Maximum separation between emitter and receiver 10m. Aligns horizontal and vertical machines, aligns coupled and uncoupled shafts equally well. Ultra modern computer design, backlit colour display, Intel xScale 400MHz CpU, USb for peripheral devices, pC, printer, also bluetooth communication. backlit keyboard, rechargeable Li-Ion battery pack. Machine train alignment- 14 machines. Alignment results in 3 quick steps, thermal growth computation. Rotalign Ultra Reader software included.

88

NON-DESTRUCTIVE TESTING

Page 99: 2007 Rentalsolutionsguide-Aunz Low

vibratiOn & alignment analySiSPruftechnik 1500mm Length Tension ChainspRU,AL12.116 AU1500mm length tension chains for pRU,ROT-ULTRA.Pruftechnik Rotalign Shaft AlignmentpRU,ROT AUMax alignment distance 10m. Aligns horizontal and vertical machines. Graphical display of alignment condition. Resolution 1micron, angular better than 10µRad.Pruftechnik Magnetic Sliding BracketpRU,MAG-bRKT AUDesigned to be used with the Rotalign. Used when shafts to be aligned cannot be rotated. A bracket is required for each non-rotating shaft to be aligned (ie. usually 2 will be required). Madgetech Ultrashock-EB Transportation LoggerMAD,ULTRASHOCK-Eb AUAmbient temperature, humidity, pressure and 3 axis shock acceleration logger. Ranges: -40~180ºC, 0-95%RH, 0~30pSIA (0-200kpa), -50g~50g. Memory 23,831 readings per channel. Logging interval from 1 reading per 2s to 1 reading per 12h. Sampling rate 2ms. Includes RS232 interface and setting up, downloading, graphing software.Madgetech Shock101-EB TR-Axial Transportation LoggerMAD,SHOCK101 NZbattery powered, stand alone 3-axis shock recorder, extended battery life of up to 60 days typical. Measures and records shock as the peak acceleration levels over the user defined interval. Designed for documenting dynamic environments such as moving vehicles, containers, ships, etc.Tiny Tag, Set of 6 Loggers: 3 x Shock, 2 x Temperature,1 x HumidityTIN,SHOCKSET AUFor shipping and transport testing. Includes 3 x shock loggers; these record the max G force in the programmed period. Includes a humidity logger, an internal temperature logger and temperature logger with external probe. Set also includes an f computer to download and view the results.Svantek 912A Sound Vibration Analyser SVA,912A AUType 1 sound level meter including a single axis accelerometer. Provides standard sound measurements and vibration measurements including 1/1 octave, 1/3 octave and full spectrum. Unit will store 1Mb of spectrum analysis information for waterfall plots etc. PC interface software included. Unit can make part body vibration measurements. If whole body vibration measurements are to be made the SVA,SV06A accessory must be used.Svantek SV06A Tri-axial Accel Interface for 912ASVA,SV06A AUAccessory kit for human whole body vibration measurement. provides 4 accelerometer inputs for the SVA,912A and a tri-axial accelerometer ‘whoopee cushion’ for whole body vibration. Can operate as an interface for a standard b & K tri-axial accelerometer.PCB Low G Accelerometer dc to 300 HzpCb,300A20 AUSingle axis accelerometer includes charge amplifier. Range ±20g, frequency (±5%) dc~300Hz, (±10%) ~500Hz. Shock limit ±5kg. Operating temperature -40~85OC. Weight 15g. Voltage sensitivity 100mV/g.B&K 2635 Charge AmplifierbK,2635 AU/MYbuilt-in integrators for displacement and velocity. Sensitivity to 10V/pC. bandpass filters. Operates also from external 6~28Vdc or ±14Vdc. battery operated 100h life. Required with accelerometers.B&K 4333 AccelerometerbK,4333 MYFrequency range: 2~10,000Hz. Voltage sensitivity 14~24mV/g. Charge sensitivity 14-20pc/g. Maximum sinusoidal acceleration 7500g. Maximum shock 10,000g.

B&K 4343 AccelerometerbK,4343 MYAccelerometer. Frequency range: 2~12,000Hz. Charge sensitivity 10~mV/g. Charge sensitivity 10pc/g. Maximum shock 10000g.B&K 4370 AccelerometerbK,4370 AUFrequency range 0.2Hz~5.4kHz. Voltage sensitivity 100mV/G or 8mV/ms2 (approximately) into 20GΩ. Charge sensitivity 100pC/G or 10pC/ms2. Max sinusoidal acceleration 2,000G. Max shock 2,000G. Requires 1 charge amplifier.B&K 4371 AccelerometerbK,4371 AU/MYFrequency range 0.2Hz~12.7kHz. Voltage sensitivity 10mV/G or 0.8mV/Ms2 (approximately) into 20GΩ. Charge sensitivity 10pC/G or 1pC/MS2. Max sinusoidal acceleration 6,000G. Max shock 20,000G. Requires 1 charge amplifier.B&K 8301 AccelerometerbK,8301 MYAccelerometer. Frequency range: 2~12000Hz. Sensitivity 10mV/g. Charge sensitivity 10pc/g. Maximum shock 10000g.B&K Vibration Impact HammerbK,8202 AUFor determining frequency response functions. Individually calibrated force transducer. Comes with 3 different tips and additional mass to enable pulse duration and frequency range to be determined.Piezotronics Accelerometer and AmplifierpIE,308b AUAccelerometer frequency range 1Hz~3kHz ±5%, 0.7Hz~6kHz ±10%, voltage sensitivity 100mV/g or 10.2mV/m/s2 ±2%. Range: ±50g, ±5V output, resolution 0.001g, vibration max 500G, shock max 5,000G. Supplied with pCb482A10 ICp line power unit.Linear Accelerometer +/-1G dc ResponseLIN,LSpC-1 AUDesigned for very low force levels ±1G measurement range. Operates down to dc in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%. Shock Survivability 100g. Natural Frequency 100Hz.Rion VM82 Vibration MeterRIO,VM82 NZSingle axis. Measure acceleration from 0.02~200m/s2. Velocity from 0.1mm~1m/s rms. Displacement from 0.001~100mm. AC/dc output of 1V full scale.Rion VA-10 Vibration AnalyserRIO,VA-10 AU/MYVibration analyser for rotating machinery. Measures acceleration, velocity and displacement. Stores 500 readings. LCD display with waveform, spectrum and data readout. Auto measurement function. Includes printer interface.Rion CP-10 RS-232 Printer VA10 NL05 NL14RIO,Cp-10 AU/MYprinter for RIO,VA-10. Operates from optional NiCd battery pack.Rion VA-11 Vibration AnalyserRIO,VA-11 AU/MYIncludes 2 pickup types hand held (pV55) and magnetic type (pV57). Instrument will measure acceleration, velocity and displacement. Displays rms, peak and crest factor. Uses FFT to display power and vibration spectrum. Incorporates pCMCIA card flash memory for data storage. RS-232 interface is available. Specifications pV57 1Hz~5kHz, pV55 3Hz~20kHz (velocity 3kHz, displacement 500Hz). Acceleration 0.02~316mm/s2 rms. Velocity 0.1~1,000 mm/s rms. Displacement 0.003~28.3 (EQ pp). High pass filter 3Hz, 10Hz & 1kHz. Low pass 1kHz, 5kHz & 20 kHz. Stores 500 measurements.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 89

NON-

DEST

RUCT

IVE

TEST

ING

Page 100: 2007 Rentalsolutionsguide-Aunz Low

Translock Brake Tester and Light Transmittance MetersTLI,bTM2-LTM2 AUKit contains a brake tester and a light tester check vehicle conformance for the NSW Road Worthy Certificate. brake tester measures the deceleration rate of the vehicle and the light tester measures the transmission levels of light through the windscreen.

Elcometer 402 GlossmeterELC,402 AUMeasures the gloss or specular reflection from a variety of surfaces. Range 0~199.9 gloss units per ISO 2813-1978. Measuring angles 60O & 20O. Aperture 16 x 33mm ellipse. Digital display. Statistical functions – min, max, average, standard deviation. Stores up to 4,000 readings. RS232C interface for a printer. Operates from ac mains or internal rechargeable batteries.

Texcel ATM Explosion and Ground Vibration LoggerTEx,ATM AUTriaxial geophone and overpressure (airblast) microphone with logger used to determine explosion and ground vibration characteristics. Geophone range to ±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s, 0.109mm/s up to 55.9mm/s. Microphone range 80-dbL~140dbL, resolution 0.049pa up to 122dbL (25pa), 0.40pa up to 140dbL (201pa). Sample rate 20, 50, 100, 200, 500Hz & 1kHz. bandwidth: geophone 4.5Hz~500Hz, microphone 2Hz~500Hz. Includes software and download cable. Internal memory 2Mb. power internal 12V dc 7Ah batteries. Continuous operation 240h. Supplied with 90~260V 50/60Hz charger, recharge time 8h approx. Instrument with 16 character LCD display, built into weatherproof pelican enclosure, rated Ip65. Operating temperature range 0~70OC, display 0~50OC. Also supplied with alarm light, reset button and 2 x 15m cable, ideal for vibration sensitive construction projects. External dc power supply cable also supplied.

ARL EL-235 Tri-axial Ground Vibration LoggerARL,EL-235 AUPortable logger with human exposure capability. Monitors ground and building vibration for long periods. Calculates and stores tri-axial vibration stats, vector sum stats, peak particle velocity (ppV), rms particle velocity and human exposure (HEF) stats. Includes PC based analysis software. Sensor frequency response 1Hz~500Hz. Logs interval, date, time, Leq, Lmax, temperature, battery, L0.1, L1.0, L10 & L90. Event mode logs date, time, max and duration (Real time mode = 1000 samples/s). Stores up to 4,096 intervals or events. power 70mA @ 12V.Blastronics UMX-SM-6 Explosion LoggerbLA,UMx-SM-6 AUTriaxial geophones, microphone with logger used to determine explosion characteristics. Geophones auto-ranging to 110mm/s, resolution ±0.1. Microphone auto-ranging to 140dbL, resolution ±0.25db. Sample rate 250, 500Hz & 1kHz. bandwidth geophones 4.5~500Hz. Microphone 2~500Hz. Includes software and download cable. Internal memory 4Mb. power internal 6Vdc 2,600mAh Gel-cells, operating consumption 40mA, sleep mode 10mA. Continuous operation 65h, with 1w programmable timer schedule. Instrument has a display.Labworks LW-140-141 Vibration TableLAb,LW-140-141 AUCapable of random and sine movement. Sine force 489N, random force 334N, shock force 1kN, max displacement 25mm, max velocity 17.8m/s, accel bare table 110g pk, accel 45kg 55g pk, accel 2.2kg 18g pk. Max accel resonant 150g pk, max accel peak shock 200g pk. Unit requires a signal source and an accelerometer to measure the acceleration. Signal source could be a function generator or random noise generator.

vibratiOn & alignment analySiS

>NEW Panametric NDT Epoch-LT Ultrasonic Flaw Detector

pAN,EpOCH-LT AUHandheld flaw detector with fast and bright LCD mono display, update rate 60Hz, automated transducer calibration. Display freeze holds waveform and soundpath data, soundpath data viewable in inch, mm or microseconds. peak memory feature, RF display mode, alarms, theshold positive/negative, or minimum depth. Numeric data logger. EMAT probe compatibility (E110-Sb). Standard DAC and TVG. Software options fitted- Echo-Echo and Square wave pulser. No probes supplied or connection cables. Refer pAN,TRAN-KIT.

>NEW Panametric NDT Kit of 3 Transducers, Wedges & Cal Block

pAN,TRAN-KIT AUKit of 3 Ultasonic transducers, comprising 1x V540SM angle beam transducer 13mm, 2.25MHz, 1x V541SM angle beam transducer 13mm, 5MHz, 1x Single crystal transducer, 0DEG, 13mm, 5MHz, 3x wedge, 1x 45DEG, 1x 60DEG, 1x 70 DEG. 1x 1M lemo cable, 1x 5 step calibration block, 12.5, 10.0, 7.5, 5.0, 2.5mm (1018 steel).Phynix Ferrous/Non Ferrous Coating Thickness TesterpHY,SURFIx FN AUThickness tester with memory and statistics. Supplied with external probe, calibration standards and carry pouch. Measurement range 0~1,500µm or 0~60mils (selectable), tolerance ±1µm +3% of reading, resolution 0.1µm. Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min substrate thickness type F 0.5mm, type N 50µm. Calibration factory, zero, foil. Data memory 80 readings max. Interface infra-red down load data to PC utilising hyper terminal.

90

NON-DESTRUCTIVE TESTING

glOSS meaSurement

autOmOtive

nOn-deStructive teSting

Page 101: 2007 Rentalsolutionsguide-Aunz Low

Defelsko FNS2 Ferrous & Non Ferrous Coating Thickness TesterDEF,FNS2 AUStorage of up to 250 readings. Supplied with external probe, calibration standards and carry pouch. Measurement range 0~1.5m or 0~60mils (selectable), tolerance 0~50mm ±1mm, +1% of reading, greater than 50mm ±2µm, +1%, resolution 0.1mm. backglow display, HiLo limits audible and visible alerts when measurements exceed specified limits. Continually displays updates average, standard deviation, min/max thickness and number of readings while measuring. Hi resolution mode for greater precision. Built in infra red port for down loading data.

Elektrophysik Mini-100FN Coating Thickness MeterELE,MINI-100FN AUMeasuring range 0~1500µm, tolerance ±2µm or 3% of reading. Operates on both ferrous and non-ferrous substrates.Defelsko POS100-C3 Ultrasonic Thickness GaugeDEF,pOS100-C3 AUMeasure coatings on concrete, paint and lacquer on wood, paint on plastic, paint on glass, glazing on ceramic, floor coatings, etc. Range 50µ~4.5mm ±2µ, ±3% of reading. Calculates max, min, mean, tolerance and SD. Stores 1,500 readings in 100 groups for statistical calcs. PC interface & software. Battery operated.Defelsko Positest Pull Off Adhesion Tester for Concrete & MetalDEF,pOSITEST AUMeasures the force required to pull a specified test diameter of coating away from its substrate using hydraulic pressure. Pressure is displayed in both MPa and PSI on a precision dial indicator and can be related to the strength of adhesion to the substrate. Suitable for coatings on both metal and concrete surfaces. Conforms with standards ASTM D4541 and ISO 4624.

>NEW PCWI High Voltage Pulse Crest Meter

pCW,HV-pULSE CREST AUMeasure and indicate peak voltage.

>NEW PCWI 40kV Pulse Porosity (Holiday) Detector

pCW,p40-pULSE AUPulse porosity (Holiday) detector. Detects pinholes in coatings and wrapping above 150µm on metal substrates such as pipes and tanks. Can be used on dry or wet surfaces. 0~40kV output, 4 digit LED display of voltage, alarm sensitivity setting between dry and wet. Supplied with rechargeable battery, 10h charger, red probe handle and 2m length of rubber coated cable, 60mm connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension and 80mm probe extension.

PCWI Hi-Lighter Holiday DetectorpCW,HI-L AU/NZDetects pinholes in coatings and wrappings on metal substrates such as pipes and tanks. 0~20kV, 3½ digit LCD display of voltage, variable alarm level. Portable with rechargeable batteries, includes probe and handle, extension probes and a variety of brass wire brushes for both flat and curved surfaces such as pipes.PCWI 30kV DC Porisity (Holiday) DetectorpCW,DC30 AUDC Porosity (Holiday) detector. Detects pinholes in coatings above 150um on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display with battery indicator, display of voltage level. Alarm indicated on front panel, supplied with rechargeable battery, 10h charger, probe handle with neon and 2m length cable, 60mm connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension. Dry conditions.PCWI 40kV Pulse Porosity (Holiday) DetectorpCW,DC30-pULSE AUPulse Porosity (Holiday) detector. Detects pinholes in coatingsand wrapping above 150um on metal substrates such as pipes and tanks. Can be used on dry or wet surfaces. 0-40kV output, 4 digit LED display of voltage, alarm sensitivity setting between dry and wet. Supplied with rechargeable battery, 10 hr charger, red probe handle and 2m length of rubber coated cable, 60mm connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension and 80mm probe extension.Mitutoyo S-211 Surface Roughness GaugeMIT,S-211 AUSurface roughness tester comprising an LCD display and a detachable detector/drive unit. parameters measured in Ra, Rz, and Rmax units. Tip radius 5mm. Data output. NiCd batteries.Mitutoyo SJ-201P Surface Roughness TesterMIT,SJ201-NATA AUComprises LCD display and a detachable detector/drive unit. parameters measured in Ra, Rq, Ry, Rz, Rt, Rp, R3z, Rk, Rpk, Rvk, S, Sm, pc, mr, Mr1, Mr2, A1, A2, Vo units. Ranges: 350, 100, 50µm & 10µm, resolution from 0.01~0.4µm. Tip radius 5mm. Data output. NiCd batteries.

nOn-deStructive teSting

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 91

NON-

DEST

RUCT

IVE

TEST

ING

Page 102: 2007 Rentalsolutionsguide-Aunz Low

nOn-deStructive teStingMitutoyo 293-330 Digital MicrometerMIT,293-330 AUWater resistant and coolant proof (IP65) digimatic micrometer, measuring range 0~1”, 0~25mm. Resolution .00005”, 0.001mm , quantizing error ±1 count, LCD display. Temperature operating range 5~40OC, storage -10~60OC. button settings: origin, zero/AbS, inch/mm, hold.

Panametrics 26 mg Pocket Thickness GaugepAN,26MG AU/NZRange 1~500mm, fast min mode. Resolution 0.01mm. probe operates -20~150OC.Panametrics NDT 37DL-Plus Ultrasonic Thickness GaugepAN,37DL-pLUS AUThickness gauge with large display (A-scan), which will display the returned waveform. It has echo-echo through-paint capability. Supplied with WIN37DL pLUS software and cable. The supplied probe is 11 mm diameter with a 1~500 mm operating range and a -20~500OC temperature operating range. The instrument has a MIL-STD-810E hazardous area operation.

Panametrics 36DL Plus Thickness GaugepAN,36DLpLUS AULarge display (A-scan), which displays the returned waveform. Echo-echo through-paint capability. Supplied with WIN95 software and cable. Supplied probe is 11mmØ with 1~500mm operating range and -20~500OC temperature operating range. Instrument has a MIL-STD-810E hazardous area operation.Panametrics 25DLHP Thickness GaugepAN,25DLHp AUDesigned for fiberglass, rubber composites and castings. Measures standard steel, copper, etc. Does echo-echo measurements. Measures the thickness of material under paint, etc. built in 5,000 reading datalogger and an RS232 port.Krautkramer DMS Thickness GaugeKRA,DMS AUComplete with echo verification and logger. Includes high temperature probe and cable. Incorporates a wave form display for accurate assessment of material under test, measurement of thickness whilst ignoring external paint. probe will operate to 200OC without cooling, up to 540OC with cooling. Measurement ranges 0.75mm~250mm (for different ranges other probes are available). Resolution 0.01mm. Stores up to 80,000 readings or 1,200 readings with full waveform information.Sonatest Thickness GaugeSON,T-GAGE-IV+ AU/MYRange 0.63~500mm, resolution 0.01mm, high speed scanning mode, selectable backlight, alarm mode, differential mode, RS232C output, data send using hyper terminal. Supplied with high temperature probe, temperature range 0~340ºC.

cOncrete teSting equipmentELE Type EL35-2020 Concrete Cover MeterELE,EL35-2020 AU/NZNon-destructive measurement of concrete thickness above steel reinforcement rods. Measures rod diameter. Depth range 360mm for rod diameters 6~40mm & 200mm depth for rod up to 6mmØ. Small search head 80H x 50mmØ. provides a high resolution capability when mapping out reinforcement structures. Range 100mm with 6mm bar to 120mm with 40mm bar. battery operated.Profometer-4 Rebar LocatorpRO,pROFO-4 MYRebar locator.Steinkamp BP7 Ultrasonic Concrete TesterSTE,bp7 AUMeasures the time a signal takes to propagate through a material. Used for concrete refractory bricks, tile (fired and unfired), outcropping rocks, tunnel walls, frozen ground, electrolytic carbon, plastics, adhesion, cast iron and wood etc. Technique relies on the fact that the pulse velocity relates to the materials tensile strength. Instrument can be used to determine % steel in concrete, variations in the moisture content, measurements of crack depth, voids, etc.

Protimeter SM Moisture MeterpRO,SM AUMoisture meter for survey work. Very good for determining wet points. Can be used on both concrete and timber. Subsequent accurate measurements can then be made.Proceq LR Concrete Test HammerpRO,LR AUConcrete hardness tester (Schmidt hammer). Supplied with in-built mechanical chart recorder. Impact energy 0.735Nm, 0.075kgm. For concrete thickness less than 100mm.Protimeter CMIII Concrete Moisture MeterpRO,CMIII AUMeasures concrete moisture content using 2 methods. Firstly using impedance as a direct instant method. Secondly an accurate method requiring placing a box on the concrete and measuring the humidity generated by the concrete.

92

NON-DESTRUCTIVE TESTING

Page 103: 2007 Rentalsolutionsguide-Aunz Low

Protimeter Moisture Measurement SystempRO,MMS-pLUS AUMoisture meter for detection of moisture in non conductive solid materials such as wood and masonry. Two measurement modes, search for qualitaive measurements and measure mode for precise and locaised moisture content. Supplied with pin type probes, deep wall probes, hygrometer probe and extention cord,for RH, ambient temperature or dew point temperature. Hygrostick probe supplied for surface temperature measurement. Logging software and RS232 computer interface supplied.Proceq 2000-ND Digi Schmidt Test HammerpRO,2000-ND AUConcrete hardness tester (Schmidt hammer). Supplied complete with inbuilt graphical LCD for setting up and graphical display of results,up to 500 results can be stored. RS232 interface and software supplied for down loading. Impact energy 2.207Nm. Engineering units of results in N/mm2, Mpa, psi, kg/cm2. For concrete thickness greater than 100mm.

Olsen FTG Concrete Thickness GaugeOLS,FTG AUConcrete thickness gauge utilising the impact Echo test method. Can measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m. This concrete thickness gauge is a battery operated handheld system for measuring the flaws and thickness of concrete slabs, pavements, walls and other plate-like structures from one side. Up to 300 readings can be stored in the field before the memory is full. RS232 interface and transfer software supplied.

Hilti PS20 Rebar, Copper Pipe & Electrical Cable LocatorHIL,pS20 AULocalise and position of reinforcement, (rebars) copper, aluminium pipes and unshielded live electric cables. Depth range for detection of rebars 0~100mm, for copper & aluminium pipes 60mm, rebar diameter 8~36mm, depth detection accuracy 10~30mm ±2mm, above 30-60mm ± 2mm ±10% depth, above 60~80mm ±5mm ±10% depth, based on 12mm rebars. Detection of copper & aluminium pipes based on 10~30mmØ, only detection with depth of 0~60mm, no depth reading, same for live electric cables, cannot detect live cables in metal conduit or shielded cables.

Hilti Ferroscan Concrete Reo ScannerHIL,FERROSCAN AUReinforced concrete imaging system. Displays depth of concrete coverage, location of reinforcement rods and anchor setting points. Fast, simple operation. Depth mode allows reinforcement rods at different depths to be viewed. Printer interface and PC interface and software allow images to be printed and/or stored for further use. Depth coverage up to 180mm. Reinforcement rod diameter measurement range 6~36mm. Area covered in a single measurement run 600 x 600mm; 42 image memory allows total 15m2 coverage without downloading.

cOncrete teSting equipment

Krautkramer DynaPocket Rebound Hardness TesterKRA,DYNApOCKET AUbased on the Leeb’s method HL, utilising a 3mm tungsten carbide ball. Other hardness scales can be selected, HS Shore, Hb brinell, HRb Rockwell b, HRC Rockwell C, HV Vickers and N/mm2 tensile strength. Choice of 9 material groups can be selected, they are St Low-alloy/unalloyed steel and cast steel, ASt Tool steel, SSt Corrosion resistant steel, GCI Gray cast iron, NCI Nodular graphite cast iron, AL Aluminium cast alloys, brS brass, brZ bronze, Cu Wrought copper alloys.

Proceq Equotip Hardness TesterpRO,EQUOTIp AUTest probe on a flexible lead. Probe type D is standard catering for most materials. Measurement ranges steels 80~650Hb, 80~940HV, 20~68HRC, aluminium castings 20~160Hb, cast iron 90~380Hb, brass 40~170Hb & copper wrought alloys 43~315Hb. Test hardness must not exceed 940HV. Battery operated.Bareiss HPE FM02177 Shore A Hardness TesterbAR,HpE-FM02177 AUDurometer tester for general rubber, elastomer, soft plastic, tires, rubber rolls & rubber hoses. Surface min 35mmØ, material thickness of 6mm are necessary for a hardness test according to the standards. Hardness tests can be conducted in a vertical, horizontal positions and on places which are difficult to reach. Test time setable from 0~30s. Reading exactness of ±0.5 Shore and according to set down standards deviation of ±1 Shore.

hardneSS teSterS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 93

NON-

DEST

RUCT

IVE

TEST

ING

Page 104: 2007 Rentalsolutionsguide-Aunz Low

Model Type Analog Out

Pressure (Bar)

Vacuum(Bar) Battery RS232 Accuracy % Current

mACurrent

Source mAAMb,CAL-20MpA Pressure pneumatic 200 0.5 fs

AME,HL2700N Dead weight tester hydraulic 225 0.05 readingAME,ppCE-NATA* Pressure hydraulic 700

Yes

0.04 reading 50bEA,bIC200 Industrial incl. Pressure 1 100 50

DRU,DpI603-10-NATA*

Pressure pneumatic

10

0.85 0.075 fs

55

55DRU,DpI603-20 20

DRU,DpI603-2NATA* 2DRU,DpI603-20NATA* 20 YesDRU,DpI610-20NATA* Yes Yes 0.025 fs 24

DRU,DpI610-160 160 0.025 fs 24 DRU,UpS-3

Current loop0.01 24

DRU,UpS-IS 0.25 55

FLU,725

Industrial 110 22FLU,725-NATA*

FLU,743bYes

FLU,744 Industrial (hart)FLU,700S/W-DpC-

TRACK S/ware for Fluke 743b & 744

GRA,W6-NATA* Water bath 0.1HAL,KAL84 Very low pressure 10 Yes Linearity ±0.5%

DRU,DbC150TC

Dry well temperature

0.3°C

HAR,9100-A 0.5°C

HAR,9105-NATA*Yes

0.1

HAR,9107-NATA* 0.1°CHAR,9141-NATA* 0.5JOF,LpC-NATA* Pressure Yes 10 0.8 Yes 0.1 fs 200m

SER,NOVA-1 Dry well temperature 0.1°CSI,pC6-2-NATA*

Pressure pneumaticYES

2 0.85

Yes Yes 0.025 fs 50 50SI,pC6-20-NATA* 20

1.0SI,pC6-40-NATA* 40

Sp,pC6-1000-NATA*

HAR,9150 Thermocouple furnance No Yes ±0.5°C

HAR,9170-R-NATA* Metrology well calibrator Yes ±0.01°C

HAR,3125-NATA* Temperature surface probe calibrator Yes

±0.5°C~200°C,±1%~400°C

JOF,1200SE Temperature calibrator 150~200°CHAR,7102-NATA*

Temperature micro bath Yes ±0.25°CHAR,7103-NATA*

FLU,718

Pressure calibrator

YesSI,pC6-pRO 350 350

DRU,DpI610-2-NATA* 2 -1 Yes 0.025°C ±55 0~24DRU,DpI610-400-NATA* 400 Yes 0.025°C ±55 0~24

SI,HTP1Pressure pump

1,000SI,TpI-40 40 -1

induStrial calibratOrS

* Nata Calibrated

94

GENERAL INDUSTRIAL EQUIPMENT

Page 105: 2007 Rentalsolutionsguide-Aunz Low

Model Type FreqkHz

Freq Source

kHz

Loop Power

VResist

MeasuremtRTD/TC

TempSource °C

Voltage Max V

Voltage Source V

AME,ppCE-NATA* Pressure hydraulic 30

bEA,bIC200 Industrial incl. Pressure 48 200Ω 100DRU,DpI603-10-NATA*

Pressure pneumatic 24

50DRU,DpI603-20

DRU,DpI603-2NATA*DRU,DpI603-20NATA*DRU,DpI610-20NATA*

DUR,DpI610-20ISDRU,DpI610-160 24 10

DRU,UpS-3Current loop

DRU,UpS-ISFLU,701-NATA*

Industrial

500

524 11kΩ Yes 300 11

FLU,72550

FLU,725-NATA*FLU,743b

500FLU,744 Industrial (hart)

FLU,700S/W-DpC-TRACK S/ware for Fluke 743b & 744

GRA,W6-NATA* Water bath 0~150HAL,KLA84 Very low pressure

DRU,DbC150TC

Dry well temperature

-45 (below amb) ~ 150HAR,9100A 40~300

HAR,9105-NATA* 40~650HAR,9107-NATA* -45~140

HAR,9141-NATA* 40~650SER,NOVA-1 200~1,000

SI,pC6-2-NATA

Pressure pneumatic24 24 10

SI,pC6-20-NATA*

SI,pC6-40-NATA*Sp,pC6-1000-NATA* Pressure Hydraulic

HAR,9150 Thermal couple furnance 150~1,200

HAR,9170-R-NATA* Metrology well calibrator -45~140

HAR,3125-NATA* Temperature surface probe calibrator 35~400

JOF,1200SE Temperature calibrator 150~1,200

HAR,7102-NATA*Temperature micro bath

-5~125HAR,7103-NATA* -30~125

FLU,718

Pressure calibratorSI,pC6-pRO 350

DRU,DpI610-2-NATA* +50 10,24DRU,DpI610-400-NATA* +50 10,24

SI,HTP1Pressure pump

SI,TpI-40

induStrial calibratOrS

* Nata Calibrated

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 95

GENE

RAL

INDU

STRI

AL E

QUIP

MEN

T

Page 106: 2007 Rentalsolutionsguide-Aunz Low

induStrial calibratOrS Fluke 5500A Multi Product Calibrator with NATA Calibrated FLU,5500A-NATA AUCalibrator sources direct voltage & current, alternating voltage and current, with multiple waveforms and harmonics, 2 simultaneous voltage outputs or voltage & current. Simulates power with phase control, resistance, capacitance, thermocouples and RTDs. Selectable ranges include the following outputs Vdc from 0~1.02kV, Vac from 1mV~1.02kV with output from 10Hz~500kHz. AC current from 0.01µA~11A with output from 10Hz~10kHz. DC current from 0~11A. Resistance values from short circuit to 330MΩ. Capacitance values from 330pF~1,100µF. Temperature t/c b, C, E, J, K, L, N, R, S, T, U, RTD pt385 100Ω, pt3926 100Ω, pt3916 100Ω, pt385 200Ω, pt385 500Ω, pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.Fluke 725 Process CalibratorFLU,725 NZDC voltage measurement 0.025%, 300V max, source 0.02%, 11V max. DC current measurement 0.025%, 110mA max, source 0.01%, 22 mA max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ max. Frequency measurement 5 counts 1Hz~50kHz, source 1 count 20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC. pt100 RTD measurement 0.5ºC, source 0.2ºC. Measures and simulates 4~20mA, t/c E, N, J, K, T, b, R, S, & C, 2, 3 & 4 wire RTDs and frequency. Operates from drycell batteries.Fluke 725 Process Calibrator NATA Calibrated FLU,725-NATA AUSpecification as above but with NATA calibration.

Fluke 743 Calibrator FLU,743b AU/MYIncludes RS232 interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V max. DC current measurement 0.025%, 110mA max, source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ max. Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3OC pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4~20mA, t/c E, N, J, K, T, b, R, S, & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Can use scaling factors for measurement & source. built in calculator. Autostep function. Allows user entered values. Operates as a 8k point data logger. Note pC software only supports 15 tags.Fluke 744 DOC Calibrator with HartFLU,744 AU/NZ/MYDocumenting process calibrator which includes HART communication protocols for communicating with and setting up smart transmitters. RS232 interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA max. Resistance measurement 0.05%, 11kΩ max, source 0.01% 11kΩ max. Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4~20 mA, t/c E, N, J, K, T, b, R, S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling factors for measurement & source. built in calculator. Autostep function. Allows user entered values. Operates as an 8k point data logger. Note pC software only supports 15 tags.

96

GENERAL INDUSTRIAL EQUIPMENT

Page 107: 2007 Rentalsolutionsguide-Aunz Low

induStrial calibratOrSFluke 700 Pxx Series Pressure Modules FLU,700pxx NZAssortment of pxx series pressure modules for the Fluke 741/744 process calibrators.Druck DBC150TC Dry Well Calibrator CalibratorDRU,DbC150TC AUTemperature range -45(below ambient)~150ºC. Accuracy 0.3ºC, resolution 0.01ºC, stability 0.03ºC. Well standard insert supplied 145mm deep, 5, 6.6 & 9.8mmØ. Heating time 14min 20~120ºC, cooling time 22min 25~-20ºC. Calibrator also measures sensor outputs, it can measure 5 types of RTD & 11 types of thermocouple. Supports 2, 3, 4 wire RTD and provides cold junction compensation for thermocouples.

Hart 9105 Dry Block Temperature Calibrator -25~140ºC NATAHAR,9105-NATA AUHAR,9105 MYRange -25~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232 interface for ramp and soak programming. Well dimensions 150mm deep, 19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.Hart 9107 Dry Block Temperature Calibrator -45~140ºC NATAHAR,9107-NATA AURange -45~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232 interface for ramp and soak programming. Well dimensions 150mm deep, 19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.

>NEW Hart 9170-R Metrology Well Calibrator with Built-in Reference & NATA Certification

HAR,9170-R-NATA AUTemperature range -45~140ºC with bult in reference thermometry. Reference input accepts (not supplied) 100, 25 and 10ohm pRT’s. Display accuracy +/-0.1ºC, stability +/-0.005ºC full range, resolution 0.001ºC. Well depth 6.3”, insert type A 1/4, 3/16, 1/4, 1/8, 1/4, 3/8”. Large LCD, numeric keypad and on screen menus. Heating time 32min 23~140ºC, 45 minutes -45~140ºC, cooling time 44min 23~-45ºC, 19min 140~23ºC. Supplied with RS232C interface and CD-ROM software.

Hart 9100-A Dry Block Temperature Calibrator 30~300OCHAR,9100-A NZStability is 0.2ºC @ 50OC & 0.3ºC @ 300ºC. Accuracy for 35~200ºC ±0.5 for 200~300ºC ±1, for well holes greater than ¼” ±2ºC.

>NEW Hart 3125 Surface Probe Calibrator 35~400ºC NATA Certification

HAR,3125-NATA AUTemperature range 35~400ºC. Display accuracy ±0.5~200ºC, ±1~400ºC. Stability ±0.2~300ºC, ±0.3~400ºC. Resolution 0.01º. Heating time 25~400ºC 22min. Cooling time 400~100ºC 65min. Temperature surface plate 3.8”Ø accessible.

Hart 9141 Dry Block Temperature Calibrator 50~650ºC HAR,9141-NATA AURange 50~650ºC, basic accuracy 0.5% (holes > ¼” 2ºC). Insert hole sizes 1/16”, 1/8”, 3/16”, ¼”, 3/8” & ½”. Includes pC software and interface cable. Heating time 1min to 650ºC. Cooling 25min from 650ºC~100ºC. Well depth 4.875”. Stabilization time 7min.Hart 9150 Furnace 150-1200ºC HAR,9150 AUTemperature range 150~1200ºC. Stability ±0.5ºC, display accuracy of ±5ºC across entire range. Display resolution 0.1º~999.9ºC, 1º above 1,000ºC. Well diameter 1.25”, well depth 5.5”, insert type A. 1/16”, ¼”, ⅜”, 3/16”, ⅛”, ½”. Heating time 35min to 1,200ºC, cooling time 140min.

Jofra 1200SE Precision Temperature CalibratorJOF,1200SE MYLightweight, portable for lab and general use. Simple single step zero setting. Temperature range 300~1200ºC. Excellent performance characteristics. Accuracy +2ºC. Stability +0.5ºC. Display in ºC or ºF to 0.1 resolution. Fast cooling and heating. User-selectable slope rates for controlled thermo switch testing. Self diagnostics includes semi-auto Switch Test & Hysteresis Test.Grant W6 Temperature Bath NATA CertifiedGRA,W6-NATA AUWater/oil bath calibrator for calibrating temperature probes. Ranges water ambient 100ºC; silicon oil ambient; 150ºC. Requires 3L oil (not supplied). Digital temperature controller and display. Stability 0.004ºC. Uniformity 0.01ºC. Display resolution 0.1ºC. Tank size 300w x 150d x 150hmm.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 97

GENE

RAL

INDU

STRI

AL E

QUIP

MEN

T

Page 108: 2007 Rentalsolutionsguide-Aunz Low

induStrial calibratOrS

>NEW Hart 7102 Temperature Micro Bath -5~125ºC

HAR,7102-NATA AURange -5~125ºC. Tank diameter 1.9”, 5.5” deep, volume 0.75L, includes tank lid. Accuracy ±0.25ºC, stability ±0.015ºC at -5OC, ±0.03ºC @ 121ºC, resolution ±0.01ºC. Heating time 25~100OC 30min, cooling time 25~0ºC 30min. RS232C interface and CD-ROM sofware supplied.

>NEW Hart 7103-NATA Micro Bath -30~125ºC NATA Certification

HAR,7103-NATA NZTemperature range -30~125ºC. Tank 2.5”Ø, 5.5” deep, volume 1L, includes tank lid. Accuracy ±0.25ºC, stability ±0.03ºC @ 25ºC, ±0.05ºC @ 125ºC, resolution ±0.01ºC. Heating time 25~100ºC 35min, cooling time 25~-20ºC 45min. RS232C interface and CD-ROM software supplied.

Druck UPS-IS Current Loop CalibratorDRU,UpS-IS AUIntrinsically safe 4~20mA source and measurement. provides 24V loop power. Accuracy 0.25%. Input and output resolution 10µA.Beamex BIC200 Instrument CalibratorbEA,bIC200 AU/MYFor both electronic and pneumatic instruments. Output ranges settable to 119.9% of range 0~10V, 1~5V, 4~20mA, 0~20mA, 10~50mA & 0~50mA. Output source for current ranges 24 & 48V. Input ranges to 4½ digit display 100mV, 1, 10 & 100V, 100mA, 4~20mA, 200Ω. pressure measurement ranges 0~1bar & 0.2~1bar. Operates from internal NiCd batteries or external ac.Halstrup KAL84 0-1kPa Portable Pressure CalibratorHAL,KAL84 AUportable battery operated 0-1.000kpa (0-10mbar) low pressure calibrator. Linearity ±0.5% ±1 digit, hysteresis 0.1%, medium - air and all non aggressive gases, pressure connections 6.5mm hose NW5, interior tubing 5mmØ. Analogue output 0-1V, display 41/2 digit, power supply via mains adaptor 100-240Vac & NiCd re chargable battery pack.

>NEW Jofra C650 Calibrator

JOF,C650 MYA fast, timesaving, and reliable true temperature calibrator designed for on-site use. produces temperatures between 33~650°C. Display resolution ±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth 120mm x 28Ømm. Comes with a multi-hole insert of ⅜”,¼”, 3/16” & ⅛”Ø holes. Light weight and portable.

Jofra LPC Pressure Calibrator NATA CalibratedJOF,LpC-NATA AURange to 10bar (145psi). Display 4½ digit, can display in bar, psi, mercury & H2Og. Analogue output 2Vdc. Includes adaptors ¼”bSp to various bSp & NPT. Measures pressure and vacuum. Battery operated.Druck DPI603 2Bar Pressure Calibrator NATA CalibratedDRU,DpI603-2NATA AUAccuracy 0.075% fs includes pump for vacuum and pressure. pumps to 20bar pressure & -850mbar vacuum. Measurements can be made to 2bar positive pressure & -1bar vacuum. Unit has a 24V energising voltage. Monitors loop current to 55mAdc loop voltage to 50V. Sealed to Ip65. Rechargeable battery operated. Displays in 24 different units. Interface 1/8”bSp.SI PC6-2-NATA Pressure Calibrator & Pump -1~2Bar 0.025% AccuracySI,pC6-2-NATA AUSI,pC6-2 MY Range -1~2bar. Measures voltage 0~100mV (1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all at 0.025% accuracy. Will sources 0~10V (0.2mV resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1%, current 30mA and unregulated supply 24V ±10% current 50mA. pressure switch status. Complete with a full range of pressure connection adaptors. Record logging capability 444 and RS232 interface download to spread sheet files. Battery operation 10h or mains operation via charger. SI PC6 Pressure Calibrator & Pump 20 Bar 0.025% AccuracySI,pC6-20-NATA AUbasic accuracy 0.025%. Range output pressure to 20bar, output vacuum to -1bar. NATA certified Instrument. Measures voltage 0~100mV (1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current 0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA and unregulated supply 24V ±10% current 50mA. pressure switch status. battery operation 10h or mains operation via charger. Complete with a full range of pressure connection adaptors.SI PC6-40-NATA Pressure Calibrator & Pump NATA Certified SI,pC6-40-NATA AUbasic accuracy 0.025%. Range is 40bar. Measures voltage 0~100mV (1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA and unregulated supply 24V ±10% current 50mA. pressure switch status. Complete with a full range of pressure connection adaptors. Record logging capability 444 and RS232 interface download to spread sheet files. Battery operation 10h or mains operation via charger.

98

GENERAL INDUSTRIAL EQUIPMENT

Page 109: 2007 Rentalsolutionsguide-Aunz Low

SI PC6-PRO 350Bar Pressure Calibrator & HTP1 Hydraulic PumpSI,pC6-pRO 350 MYRange 0~350bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all @ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA & unregulated supply 24V ±10% current 50mA. pressure switch status. Pressure media oil, water & non corrosive gases. Battery operation 10h or mains operation via charger. Complete with a full range of pressure connection adaptors.SI PC6 700Bar Pressure Calibrator & HTP1 Hydraulic Pump NATA CalibratedSI,pC6-700-NATA AUSI,pC6-700 MYRange 0~700bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all @ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1uA resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA & unregulated supply 24V ±10% current 50 mA. pressure switch status. Pressure media oil, water & non corrosive gases. Battery operation 10h or mains operation via charger. Complete with a full range of pressure connection adaptors.SI PC6 Pressure Calibrator & Pump 1000 BarSI,pC6-1000-NATARange is 1,000bar. Nata calibrated Instrument. Measures Voltage 0~100mV (1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current 0~50mA (1µA resoultion) @ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA and unregulated supply 24V ±10% current 50mA. pressure switch status. pressure media oil and water (unit can measure non corrosive gases but not pump them). Battery operation 10h or mains operation via charger. Complete with a full range of pressure connection adaptors.SI Pressure HTP1 Pressure PumpSI,HTP1 NZHand operated hydraulic pressure pump, capable of 700bar. Quick priming and pressure generation. High pressure/priming selector. Fine adjustment control. pressure release valve. Supplied with integral IANZ calibrated digital gauge. Uses paraffin oil as the working fluid.SI Pressure TP1-40 Pressure PumpSI,Tp1-40 NZFully portable hand operated dual source of pneumatic pressure and vacuum. Generates up to 40bar pressure or 96% vacuum. Adjustable stroke to provide over pressure protection. Supplied with thread adaptors. Reference gauge is required, see optional Fluke pressure modules FLU,700pxx.Druck DPI603 Pressure Calibrator 10Bar NATA CertifiedDRU,DpI603-10-NATA AUDisplays in 24 different units. Interface ⅛”bsp. Accuracy 0.075%fs, includes pump for vacuum and pressure. pumps to 20bar pressure & -850mbar vacuum. Measurements can be made to 20bar positive pressure & -1bar vacuum. Unit has a 24V energising voltage. Monitors loop current to 55mA dc @ ±0.075% reading & 0.005%fs. Monitors loop voltage to 50V @ ±0.15% of reading & 0.02%fs. Unit sealed to Ip65. battery life per charge is approx 40h (no 24V load).Druck DPI603 Pressure Calibrator 20BarDRU,DpI603-20 AU/MYAccuracy 0.075%fs. pumps up to 20bar pressure & -850mbar vacuum. Measures up to 20bar pressure & -1bar vacuum. In-built 24V energising voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface ⅛”bsp. battery operated.

Druck DPI603 Pressure Calibrator 20Bar NATA CertifiedDRU,DpI603-20NA AUIncludes pump for vacuum and pressure can display in 24 different units. Interface ⅛”bsp. Accuracy 0.075%fs. pumps 20bar pressure & -850mbar vacuum. Measurements can be made to 20bar positive pressure & -1bar vacuum. Unit has a 24V energising voltage. Monitor loop current to ±55mAdc @ ±0.075% reading & 0.005%fs. Monitor loop voltage to 50V @ ±0.15% of reading & .02%fs. Unit is sealed to Ip65. battery life per charge is approx 40h (no 24V load)Ambit Calibration Kit 20MPaAMb,CAL-20MpA AU20Mpa gauge with hydraulic hand pump, accuracy 0.5%fs.Druck DPI610HC 160Bar Pressure Calibrator DRU,DpI610-160 AUHydraulic pressure calibrator including pump and current voltage standard. pressure range 160bar ±0.025%fs. Voltage input ±50Vdc, ±0.05% reading & ±0.004%fs. Current input ±55mA, ±0.05% reading & ±0.004%fs. Temperature 10~40OC, ±1 (ambient) switch open/closed. Voltage output 10Vdc, ±0.1% or 24V ±5%. Current output 0~24mA, ±0.05% reading & ±0.01%fs. Datalogger stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8“(f). pump includes screw adjustment.

>NEW Druck DPI610~20~NATA 20Bar Pressure Calibrator NATA Certification

DRU,DpI610-20-NATA AUPneumatic pressure calibrator including pump and current voltage standard. pressure range -1~20bar ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg, ±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature -10~40°C ±1°C (ambient) switch open/closed. Voltage output 10Vdc ±0.1% or 24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger stores upto 10,000 values. mA ramp configurable. pressure port G ⅛f, includes flexible hose kit. pump includes screw adjustment.

>NEW Druck DPI610~20IS Pressure Calibrator

DRU,DpI610-20IS MYRanges -1~20bar. Accuracy 0.025% fs all ranges. Integral combined pressure/vacuum pump. Dual readout: input & output. 4~20mA loop test: auto step and ramp. RS232 interface and fully documenting version. Remote pressure sensors. Intrinsically safe version.

induStrial calibratOrS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 99

GENE

RAL

INDU

STRI

AL E

QUIP

MEN

T

Page 110: 2007 Rentalsolutionsguide-Aunz Low

induStrial calibratOrS

100

GENERAL INDUSTRIAL EQUIPMENT

Druck DPI610-2-NATA 2 Bar Pressure Calibrator DRU,DpI610-2-NATA AUPneumatic pressure calibrator including pump and current voltage standard. pressure range -1~2bar, ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg, ±0.004%fs. Current input ±55mA, ±0.05%rdg, ±0.004%fs. Temperature -10~40°C, ±1 (ambient) switch open/closed. Voltage output 10Vdc, ±0.1% or 24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger stores up to 10,000 values. mA ramp configurable. pressure port G 1/8” (f), includes flexible hose kit. pump includes screw adjustment.

Druck DPI610-400-NATA 400 Bar Pressure Calibrator DRU,DpI610-400-NATA AUDRU,DpI610-400 MYHydraulic pressure calibrator including pump and current voltage standard. pressure range 0~400bar ±0.025%fs. Voltage input 50Vdc, ±0.05%rdg, ±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature -10~40ºC ±1ºC (ambient) switch open/closed. Voltage output 10Vdc ±0.1% or 24V ±5%. Current output 0~24mA, ±0.05% rdg, ±0.01%fs. Data logger stores up to 10,000 values. mA ramp configurable. pressure port G 1/8” (f), includes flexible hose kit. pump includes screw adjustment.

>NEW Druck Loop Calibrator

DRU,UpS-3 AUMeasure and source 0~24mA, accuracy 0.01% of reading, dual mA and % readout, linear or flow. Step, span check, valve check, ramp. Measurement and continuity 60Vdc. HART compatible internal 235Ω loop resistor, menu selectable. Large graphic LCD.

Ametek PPCE 700 Bar Pressure CalibratorAME,ppCE-NATA AU/MYHigh pressure calibrator with pump 700bar (10,000psi). Digital display with 5 digit resolution. Accuracy over 70bar ±0.07. Accuracy below 70bar ±0.35. Current and voltage measurement ranges 4~20mA, 0~50mA & 0~30V.Ametek Hydralyte HL2700N Dead Weight TesterAME,HL2700N AU/MYDual range interchangeable piston:-100~4,500kpa, 0.5kpa increments, 500~22,500kpa, 1kpa increments. Accuracy 0.05% of reading. Includes special calculator for high accuracy pressure calculations and also conversion of units.

Soniclean 1000HT Ultrasonic Cleaning Bath SON,1000HT AUTank size 495w x 295d x 150h mm includes heater and timer.

Soniclean 2000HT Ultrasonic Cleaning Bath SON,2000HT AUTank size 495w x 295d x 299h mm includes heater and timer.

ultraSOnic bathS

Page 111: 2007 Rentalsolutionsguide-Aunz Low

envirOnmental teSt chamberS/OvenS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 101

GENE

RAL

INDU

STRI

AL E

QUIP

MEN

T

>NEW Angelantoni CH340 Environmental Temperature Chamber

ACS,CH340C AUTemperature range -75~180ºC, humidity range from 10~98% RH in the range of 10~80ºC, dew point range 2~94ºC for continuous tests. Relative humidity accuracy ±1%~±3%. Capacity 336lt. Internal 600w x 800d x 700h mm. External dimensions 850w x 1725d x 1516h mm. Control by uPLC & graphical control panel on the door. Program temp & RH cycles and control all chamber functions and alarms. Entry port, door with inspection window, internal lighting, 1 shelf, RS232C interface. Electrical rated power 5.7kW, maximum used power 9kW. Voltage 400 +6%, -10%, 50Hz, 3ph. Noise 63dbA , weight 750kg approximately including transit case.

ACS CH106C Temperature & Humidity Environmental ChamberACS,CH160C AUTemperature range -70~180ºC, humidity range from 20~95%RH in the range of 10~80ºC, dew point range 5~79ºC for continous tests. Realtive humidity accuracy ±1%~±3%. Useful capacity 178L, internal 560w x 564d x 560h mm. External dimensions 760w x 1115d x 1370h mm. Control by micro pLC and control panel placed on the door (4 lines alphanumeric display and keyboard). pLC programs Temp & RH cycles and to control all chamber functions and alarms. Entry port 80Ømm, door with 230 x 230mm window, internal lighting, 1 shelf, RS232C interface. Dissipation at -55ºC,100W. Electrical power 4.5kW (average 3.3kW). Voltage; 230V +6%, -10%, 50Hz, 1ph. Noise 60dbA measured at 1m from the front in a non reverberating room. Weight; 390kg (excluding transit case).

ACS Trolley for CH160C Environmental ChamberACS,TROLLEY AU

ACS Winkratos Software for CH160C Temperature & Humidity ChamberACS,WINKRATOS AUSoftware for remote control of ACS,CH160C temperature and humidity chamber. Remote programming and control of chamber plus report generation. Includes Compaq Armada E500 pentium III 500MHz notebook computer & RS232C interface cable.Memmert ULE400 Laboratory OvenMEM,ULE400 AURange 30~220OC. Capacity 53L, internal 400w x 400d x 330h mm. Two shelves. Electronic temperature control with max deviation of 0.8~4OC.Labec OTWMD18 Laboratory OvenLAb,OTWMD18 AUFan forced laboratory oven, ambient to 200OC. Capacity 66L, digital temperature controller.Tenney TJR Environmental Temperature ChamberTEN,TJR AURange -80~200OC. Workspace 400w x 280h x 300d mm. In transit case 1350w x 720d x 1050h mm. Operates in case with lid off. Programmable controller 24 step display resolution 1OC. Heating rates 25~100OC, 15min or 25~200OC, 55min. Cooling rates 25~-40OC, 20min or 25~-80OC, 65min. Access port 50mmØ.

AES LH-6 Temperature Humidity ChamberAES,LH-6 NZInternal dimensions 610w x 510d x 480h mm. External dimensions 1170w x 840d x 790h mm. Operating range temperature -20~94OC, ±0.5 at sensor. Humidity 20~98%RH ±2% at sensor. Includes self contained humidity system, 200 x 200mm window, access port, microprocessor controller and high/low safety shut down.

Model Type Temperature°C Humidity %RH Size (litres)

AES,LH-6

Temperature & humidity chamber

-20~94 20~98 150

ACS,CH160C -70~180 20~95 178

ACS,CH340C -75-180 10-98 336

LAb,OTWMD18Laboratory oven

30~200 66

MEM,ULE400 30~200 53

TEN,TJR Temperature chamber -80~200 33.6

Page 112: 2007 Rentalsolutionsguide-Aunz Low

Kane-May KM1242 5 Channel Indicator & RecorderKM,KM1242 AUFive channel temperature indicator and recorder. Range -100~1300OC, resolution 0.1. Uses type K thermocouples. Gives average, max and min for period recorded. Operates from NiCd batteries or ac adaptor.Hanna HI98704, 4 Channel Thermocouple PrinterHAN,HI98704 AUFour channel thermocouple input temperature display and printer. Accepts all common thermocouple types including K & T.Haenni KRK ThermohygrographHAE,KRK501 MYTemperature -10~50ºC. Humidity 0~100%. Accuracy, thermograph ±1%fs, hygrograph: ±4%fs.

Micromech MM-01 ThermohygrographMIC,MM01 AURecording ranges -10~50OC & 0~100%RH. Specify 7d or 24h charts.Hobo Pressure LoggerHOb,pRES AURange 0.5~16psia. Safe operating temp range -39~75OC. Size 46w x 148d x 15hmm & 255g. Stores 1,800 measurements, 42 preset intervals. Data can be exported to spreadsheet. Logs in meters, feet, mbar and Hg. Battery life 2y.Dickson PR500 Pressure LoggerDIC,PR500 NZRecords pressure in water and gas lines. Compact size is perfect for tight locations. Water resistant stainless steel case for use for outdoor applications. pressure range is 0~500pSI, accuracy is ±1% of full scale. Stores 7936 data points. Programming and data recovery done by TechRentals.

temperature/humidity/barOmetric recOrderS

>NEW Fluke 576 Photo Temp Infrared Thermometer with Built-in Camera

FLU,576 AU/MYRange -30~900ºC. Minimum measurement 19mmØ, laser class II, 3 point spot. Includes adjustable emissivity from 0.1~1 by 0.01. Target size 1/60 of distance. Max, min, dif and av displayed on backlit lcd with bar graph. Data output USb or 1mV/ºC, windows software and cable included. Accuracy ±0.75% of reading or ±1ºC which ever is greater. Response time 250ms. Display resolution 0.1ºC. Continuous measure mode.

>NEW Fluke 52-2 Digital Thermometer

FLU,52-2 MYRelative time clock on MIN, MAx, and AVG provides a time reference events. Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy . Measures J, K, T, & E-types of t/c. Readout in ºC, ºF, or Kelvin (K). battery life: typical 1000h. battery door allows easy replacement without breaking the calibration seal. Large backlit dual display shows any combination of T1, T2, T1-T2 plus MIN, MAx, or AVG. Additional t/c type R, S, & N (a total of 7 types). Recall function allows logged data to be reviewed on the display. IR communication port allows data to be exported to optional FlukeView Forms® Temperature pC software for further analysis and graphing. Data Logs up to 500 points of data with user adjustable recording interval.

Model Type Temperature Range ºC Output Ratio Type

KType J, T, E, N,

R, SANA,AN2406 Precision RTD thermometer -20~200 Serial & analogue RTD RTD

FLU,52-2 Digital thermometer IR cxommunication port Yes

Yes

FLU,54

Dual channel digital logging thermometer -250~1,767

Logging with IR interface RS232

2 ChFLU,54-2

FLU,54Flukeview IR interface & software

FLU,54-2Flukeview Logging with IR interface USb

FLU,576 Photo temperature Infrared thermometer with built in camera -30~900 USb or 1mV/ºC 60:1 No

No

FLU,80pK3 Type K surface probe Probe

YesFLU,80TK Type K transducer Analog out

HAR,1521-NATA precision thermometer NATA -200~420 RS232

MIC,M90H IR thermometer, high temperature range 600~3,000

Analog out & RS232180:1 No

MIC,M90Z IR thermometer, narrow field of view -50~1,000

RAY,Mx4+ IR thermometer laser sighted-30~900

60:11 Ch

RAY,Mx6 IR thermometer laser sighted plus digital camera Analog & USb 60:1

TES,845 Infrared thermometer with humidity probe and thermocouple probe -35~950 USb 75:1 Yes

102

TEMPERATURE & HUM

IDITY MEASUREM

ENT

temperature meterS/ir thermOmeterS

Page 113: 2007 Rentalsolutionsguide-Aunz Low

temperature meterS/ir thermOmeterS

>NEW Testo 845 IR Thermometer With Humidity Probe and T/C Probe

TES,845 AURange -35~950ºC with built in humidity probe, range 0~100%RH. Switchable distance ratio far field 75:1 16mm, distance 1200mm, close focus 1mm, distance 70mm. Laser class II, 4 point spot/cross far field, 2 point/1point close focus. Includes adjustable emissivity from 0.1~1, max, min, displayed on backlit LCD . Data output USb windows software and cable included. Accuracy ±0.75% of reading 100~950ºC. Display resolution 0.1ºC. Continuous measure mode. plug in T/C probe supplied.

Fluke 54 Dual Input TC with LoggingFLU,54 AUDigital thermometer with data logging. Takes most t/c inputs. Accuracy ±0.05% +0.3OC. Logging 500 points with date and time stamp. Records min, max or avg. Logged data can be reviewed on meter or downloaded via IR port (see FLU,54FLUKEVIEW).Fluke 54-2 Dual Input TCFLU,54-2 AUD series 2, dual input digital thermometer with data logging. Takes J, K, T, E, R, S, N T C inputs. Accuracy ±0.05%+0.3OC. 500 point logging with date and time stamp. Records min, max or avg. Logged data can be reviewed on meter or downloaded via IR port (see FLU,54FLUKEVIEW : Fluke 54 with IR/RS232 cable & Flukeview software or FLU,54-2FLUKEVIEW : Fluke 54-2 with IR/RS232 cable & Flukeview software).Fluke 54 Dual Input TC with Flukeview Logging SoftwareFLU,54FLUKEVIEW AUSpecification as above. Logged data can be reviewed on meter or downloaded via IR port using cable and Flukeview software included.Fluke 54-2 Dual Input TC with Flukeview Logging SoftwareFLU,54-2FLUKEVIEW AUSeries 2, dual input digital thermometer with data logging. Will take most TC inputs. Accuracy ±0.05% +0.3ºC. 500 point logging with date & time stamp. Also records min, max or avg. Logged data can be reviewed on meter or downloaded via IR port RS232 interface, (using cable and Flukeview software included).Hart 1521 NATA Precision Handheld ThermometerHAR,1521-NATA AUAccuracy 0.025ºC. Includes 5614 probe ¼”Ø x 12” long. Calibrated in the -183~500ºC range. probe operating range -200~420ºC (cable and transition to 150ºC max).

Analogic Precision RTD ThermometerANA,AN2406 NZRange -20~200ºC accuracy is ±0.1, resolution is 0.01. Supplied with a calibrated probe of 150mm x 6mmØ. Serial and analogue outputs. AC or battery operation.CHY 505 Portable Digital Reference RTD ThermometerCHY,505 NZportable digital reference rtd thermometer. Range is -25~250ºC, resolution is 0.1, accuracy including probe ±0.05% of reading 0.3ºC. Supplied with pT385 RTD probe (length 150mm x 3mmØ) and IANZ endorsed calibration certificate.

Raytek MX4+ Infrared ThermometerRAY,Mx4+ AU/NZRange -30~900OC. Size of measurement target is indicated by lasers. Instrument includes Type K t/c for additional temperature measurement to set emissivity. Target size 1/60 of distance. built in emissivity table, audible/visible high low alarm. Max, min, dif and ave display. RS-232 and analog output, windows software and cable included. Accuracy ±1%, ±1OC. Response time 250m/s. Display resolution 0.1OC. Continuous measure mode.

Raytek MX6 Photo Temp Infrared Thermometer, Built in CameraRAY,Mx6 AU/NZRange -30~900ºC with built in digital camera. Min measurement 19mmØ, laser class II, 16 point circle spot. Includes adjustable emissivity from 0.1~1.0 x 0.01. Target size 1/60 of distance. Max, min, dif and av display with backlit lcd with bar graph. Data output USb or 1mV/ºC, windows software and cable included. Accuracy ±0.75% of reading or ±1ºC which ever is greater. Response time 250m/s. Display resolution 0.1ºC. Continuous measure mode. Digital camera and flash built in.

Micron M90H Infrared ThermometerMIC,M90H AURange 600~3,000OC. Focusing 500mm to infinity. Field of view for measurement 1:180 (1/3

O). Resolution 1OC. Accuracy 0.4% of reading. Recorder output 1mV/OC. RS232C interface. Battery operated. Mikron M90Z-B Infrared ThermometerMIC,M90Z AUFeatures through lens sighting and sharp focusing. Temperature displayed in view finder. Data hold, peak valley and average functions. Temperature range -50~1,000OC. Accuracy 1%, 1OC. Field of view for measurement 1:180. Rechargeable NiCd batteries give 8h life.

Fluke 80TK Thermocouple ModuleFLU,80TK AUUse with DVM’s and recorders. Accepts K thermocouples. Temperature range -50~1,000OC. Output 1mV/OC. Type 80Kp-1 probe included.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 103

TEM

PERA

TUIR

E &

HUM

IDIT

Y M

EASU

REM

ENT

Page 114: 2007 Rentalsolutionsguide-Aunz Low

thermal imaging cameraSMarconi Argus2 Black & White Thermal CameraMAR,ARGUS2 AUGives live thermal image, quick and clear image. Good for fast assessment. Applications include general industrial work, electrical work, surveillance work and termite inspection. Displays temperature in the centre of image. If the image needs to be recorded you can use the NOG,USbVIDEO or the Cannon MV400i and use the analog video in (The ARGUS2 video out is an NTSC signal). The accuracy of the temperature measurement is ±2OC or ±2% and the range is 0~500OC ±2 or ±2%. Ambient temperature measurement is ±2OC or ±5%. Display indicates a temperature difference of 0.1OC. Uses the 0.8~14µm thermal range. Dust and water proof to Ip67. battery life is 120min per battery (4 supplied).ISI 525 Snapshot Thermal CameraISI,IR777 AU/NZUncooled thermal imaging system with a 4” high resolution TFT LCD display which captures and stores an image to a pCMCIA card. A cursor on the display can be driven to any point on the image and a temperature at that point read out. Measurement range is 0~350OC. pAL video output. In-built pCMCIA card stores 72 images.External Battery Pack for ISI,IR777 Thermal Imaging CameraISI,bATTpACK-ExT AUOptional sealed lead acid battery pack for ISI,IR777 Thermal Imaging Camera. battery capacity 10Ah, includes carry case for battery with shoulder strap, smartcharger and special connector with 2m of connection cable.

>NEW Flir InfraCAM thermal Imaging Camera

FLI,INFRACAM AUSimple to use battery operated real time thermal imaging camera. In-built 3.5” colour LCD, detector resolution 120 x 120. Ranges, spectral 7.5~13µm, temperature -10~350ºC, accuracy ±2 or ±2% of reading. Imaging frame rate 9Hz, video output via USb interface, stores 50 images. Down load to pC via USb. Operating range -15~50ºC. Supplied with Quickview s/w and digital camera. Fixed spot on LCD, maximum 3 spots via software.

Flir Systems E45 ThermaCam Thermal Imaging CameraFLI,E45 AUIn-built 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral 7.5~13µm, temperature -20~250OC, accuracy ±2 or ±2% of reading. Imaging frame rate 50Hz, video output standard RCA composite video, stores 200 images, image run or freeze. Download to pC via USb. Operating range -15~45OC. Supplied with download software and Panasonic digital camera. Single moveable spot for temperature measurement. Built in tripod mounting, 1/4”-20.

104

TEMPERATURE & HUM

IDITY MEASUREM

ENT

Page 115: 2007 Rentalsolutionsguide-Aunz Low

>NEW GE Panametrics PM880 Industrial Moisture Analyser

pAN,pM880 AUIntrinsically safe moisture analyser for compressed air systems, non-corrosive gases & hydrocarbons such as natural gas (IS certification to ATEx and CSA). Displays dew point, moisture concentration, pressure & temperature. Dew point calibrated measurement range -80~20°C with data to -110°C. pressure range 7~69bar limited by sensor, gauge and safety-valve (operating range from 5µHg). Temperature range -30~70°C. Gas flow operating range from static to 10,000 cm/sec velocity. Supplied with compact sample system with gauge, safety-valve, sampling valves and fittings (¼” Swagelok). Data logging of up to 100K moisture points, with infrared port and software for download. battery powered only (15-24h operation) with second battery and charger (note charger is not IS).

Panametrics MMS35 Air/Natgas Moisture AnalyserpAN,MMS35 AUIntrinsically safe for compressed air systems and hydrocarbons such as natural gas. Displays dew point & ppm moisture by volume. Pressure set as a constant. Data logging with RS232 port for download. Operating temperature range -110~70OC. pressure range 5µHg~5,000psig. Accuracy 60~-60OC ±2, -66~-110OC ±3. Repeatability: 60~-60OC ±0.5, -66~-110OC ±1. Response time <5s for 63% step change. Gas flow range from static to 10,000cm/s velocity @ 1atm.

Model Type FeaturespAN,pM880 Industrial Moisture Analyser Intrinsically safe

pAN,MMS35 Moisture meter for air & nat gas Moisture content under pressure

PRO,SM* Concrete & timber moisture meter Two pin inspection mode & RF mode

PRO,CMIII* Concrete moisture meter Gel conductivity & standard surface humidity test

*See Concrete Testing Equipment

thermal imaging cameraS

humidity & mOiSture meterS

SAT S160 Real Time Thermal Imaging cameraSAT,S160 AU/NZWith 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral 8~14µm, temperature -20~250OC ±2 or ±2%. Imaging frame rate 50Hz, video output pAL, image storage 500 pictures, image run or freeze. Image download to pC via USb. Ambient operating range -15~50OC. Supplied with download software and panasonic DMC-FZZA digital camera.

SAT Tripod Fitting Adaptor For SAT S160 CameraSAT,TRIpOD-FIT AUTripod fixture clamps around the SAT,S160 thermal imaging camera and then allows this camera to be mounted on a tripod.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 105

TEM

PERA

TUIR

E &

HUM

IDIT

Y M

EASU

REM

ENT

Page 116: 2007 Rentalsolutionsguide-Aunz Low

Detec DH50 Hand-held Metal DetectorDET,DH-50 AUSimple to operate, no adjustment needed. Audible alarm.

Detec DH50 Hand-held Metal Detector Kit of 4DET,DH-50-KIT4 AUKit of 4 x hand held security metal detector. Simple to operate - no adjustment needed. Audible alarm.

Garrett CS5000 Walk Through Metal DetectorGAR,CS5000 AUDetects all metals. Requires assembly on-site & set-up. Adjustable sensitivity.

Garrett Superscanner Hand-held Metal DetectorGAR,SUpERSCANN AUFor security applications.Swise Surveillance Digital CameraSWI,COLOR AUCaptures up to 700 images. Includes motion detector, only takes images of changes. Can be connected to a modem to dial and transmit the images. Contact input which activates dialing so it could be connected to a DataTaker for dial out alarms. Includes software and cable to download the images to a PC directly or via a modem. Will not operate until powered. When finished, will not operate after power down. System can be configured and downloaded by TR Services (please request quotations). System draws 120mA @ 12V, operates for 3d on 10Ahr 6V batteries, or for 6d on 8 alkaline D cells or 9d on 2 lantern batteries.

AVE Serial to Video Converter Including Video MixerAVE,VSIpLUS AUMixes serial data (text) with video signal, so that a picture includes this text. Use with a GpS (eg GA,ETREx) to add a location reference to a video or used with cash register RS232 output to record transactions on a security camera picture.Elbex 1-Camera VCR Surveillance SystemELb,CCTV2 AUSingle camera time lapse video recorder. Uses pin hole camera and 24h time lapse VHS VCR. VCR can accept an alarm input from a motion detector, etc and this will provide a time stamp and trigger a period of real time recording. Camera lens 8.5mm giving 70O field of view. Video monitor included.Poptron CCD RF Camera and Receiver IR LightingpOp,RF-CCD AUVideo surveillance camera with radio frequency link. Transmits video & audio from a camera 30m~100m depending upon conditions (900~930MHz carrier). Standard video & audio output. Infrared illuminator included - range 1.5m. Optalign RF Transmitter Detector SystemOpT,bUG AURadio transmission detector system useful for ‘bug’ detection and nearby transmission interception. Comprises 3 principal units R10 FM interceptor which auto tunes to a near field transmitter - range 120m typical for 5W VHF/UHF. In-built speaker and deviation indicator. Frequency range 30MHz~2GHz. R20 AM interceptor with headphone output. Frequency range 500kHz~2.5GHz. Signal strength bar graph. Scout 40 frequency counter for off air frequency indication of near field transmissions. In-built logging permits a walk through surveillance of an area. Accessory antennas are included to optimise reception. An optional pC package permits long term surveillance - see separate model.Optalign Optalog Scanning SoftwareOpT,OpTOLOG AUpC interface and software for OpT,bUG Scout 40 frequency counter.Pacom 8 mm Colour Camera, Auto Iris, 6~15mm LensCAM,COL-AUTO AUColour surveillance camera 8mm CCD auto Iris 6~15mm lens.4 Camera Surveillance Digital Stand-Alone Record System CAM,DVMR-4C AU4 day/night colour cameras with stand-alone digital video multiplex recorder, complete system with 15” colour LCD screen, 20m connection cables, power supplies and video to USb coverter for down loading of data to pC.

Security equipment

106

SECURITY EQUIPMENT

Page 117: 2007 Rentalsolutionsguide-Aunz Low

Pulse Technology AQ-1B Underwater Metal DetectorpUL,AQ-1b AUSuitable for above ground use also. Hand-held, battery operated, complete with high sensitivity 15” search coil, compact 8” coil, and small ferrite probe. Supplied with a bone conduction phone for underwater use and headphones for above ground use. Complete with charger.Minelab SD2000 Gold Prospecting Metal DetectorMIN,SD2000 AUDesigned primarily for gold prospecting. Kit includes 2 search heads, battery and 240V and in-car battery chargers. Incorporates multi-period sensing (mps), allowing the unit to operate in highly mineralized soils (it will detect nuggets at 2~4 times the depth of a typical metal detector). battery life 16h.Cscope CS550 General Purpose Metal DetectorCSC,CS550 AUSimple to use and light weight. Ideal for locating rings, etc. Works well in locating metal underground services.Excaliber 1000 Under Water Metal DetectorExA,1000 AUMIN,Ex-1000 MYSearch coil 10”. Use effectively in or out of the water. Features 2 operating modes all metal and discriminate. In discriminate mode, ignores most ferrous objects and still detects the valuable non-ferrous objects such as gold and silver. Rechargeable battery pack separated from the electronics cylinder allows easy access for recharging.

metal detectOrS

Traffic Pro People Counter Event LoggerTRA,RETAILpACK AUCounts the number of people passing a particular point. Used to check the success of in-store promotions, counting people entering sections of a store, etc. The unit operates from internal batteries and will store one years worth of data at a 1h sample rate.

retail traffic flOW cOunterS

>>did yOu knOW….

We have Over 10,000 itemS Of SpecialiSed technical equipment in Our inventOry, SO We’re bOund tO have a SOlutiOn tO virtually any teSt and meaSurement prOblem.

tO See Our full range viSit Our WebSiteS and dOn’t fOrget tO regiSter fOr neW prOduct releaSeS tOO.

www.techrentals.com.auwww.techrentals.co.nzwww.techrentals.com.my

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 107

SECU

RITY

EQU

IPM

ENT

Page 118: 2007 Rentalsolutionsguide-Aunz Low

>>did yOu knOW….

tr cOrpOratiOn haS 30 lOcatiOnS acrOSS the aSia pacific regiOn, SO itS never been eaSier tO rent yOur teSt and meaSurement needS frOm uS.

viSit Our WebSiteS fOr cOntact detailS.

www.techrentals.com.auwww.techrentals.co.nzwww.techrentals.com.my

Page 119: 2007 Rentalsolutionsguide-Aunz Low

ENVIRONMENTAL

Page 120: 2007 Rentalsolutionsguide-Aunz Low

Global FP101 Digital Water Velocity MeterGLO,Fp101 AUportable flow probe - current meter for water velocity measurements in streams, channels and partially filled pipes. propeller sensor in 50mmØ housing, fitted to telescopic handle [1.8m] with gauging marks to 900mm depth. Digital LCD flowmeter display for instantaneous liquid velocity and average, maximum, stopwatch or clock. Minimum depth about 50mm. Range 0.1~4.5m/s ±0.05.

Panametrics PT868 Ultrasonic FlowmeterpAN,pT868 AU/NZportable non-contact liquid flowmeter using transit-time principle. Includes transducers for pipe diameters 50mm~2m and temperatures -20~150OC [additional transducers available] with clamping fixture. Flow velocity range 0.03~12.2m/s. Accuracy typically 1%. Data logging capacity. Analog [current loop] and RS232C outputs, and analog inputs compatible with temperature transmitters for energy-flow calculations. Totalised flow and trend analysis. Rechargeable NiCd operation for 8~10h or operation from ac mains or external dc 10~28V supply.

Panametrics Software for PAN,PT868 & PAN,MMS35pAN,SOFTWARE AUSoftware for pAN,pT868 flowmeter and pAN,MMS35 moisture analyser. Allows storage, recall and download of instrument setup routines. Versions available to match instrument firmware revisions.

Panametrics PT868 Flowmeter NATA CertificationpAN,pT868-NATA AUSpecification as for pT868 above but NATA certification.

Panametrics 12~50mm TransducerspAN,C-Lp-40NM AU/MYTransducer pair for pAN,pT868/878 transit-time flowmeter to suit pipe 12~50mmØ. Complete with CF-Lp-50M mounting bracket. Temperature range -40~120OC.

Panametrics -20~210OC TransducerspAN,C-pT-10Hb AUHigh temperature transducer pair for pAN,pT868/878 transit-time flowmeter. Operates on pipe sizes 50mm~2mØ. Working temperature range -20~210OC.

Panametrics -200~400OC TransducerspAN,OKS AUVery high temperature, wide range transducer pair for pAN,pT868/878 transit-time flowmeter. Temperature range -200~400OC, for pipe 80mm~600mmØ. Uses special clamp system supplied. Appropriate protection and safe-handling equipment is required for fitting and operation at very high or low temperatures.

flOW meterS - liquid

Model Type Features Max Flow Temp °C Pipe Ø mm Major Application

pAN,pT868Ultrasonic

Transit timeNon-contact

Data loggingRS232C4~20mA

~12m/s -20~150 50~2,000Liquids, Energy flow

Low gas/solids contentpipes (clamp-on)

Note: NATA versions availablepAN,pT878

Data LoggingIR interfaceLarge LCD

pAN,C-Lp-40NMTransducer set,

pT868/878

-40~120 12~50 Small diameter pipespAN,C-pT-10Hb -20~210 50~2,000 Wide temperature range

pAN,OKS -200~400 80~600 Very wide temperature range

pAN,2CHRT-1-1 Temperature sensors, pT868/878

-20~130Clamp-on

pAN,2CHRT-1-2 -20~260

pAN,SOFTWARE Software PT868 & pAN,MMS35 Storage, Recall, Download

pOL,HYDRA-Sx30UltrasonicDoppler

Non-contact

Dual frequencyData logging

RS232C, 4~20 mA10m/s -40~122 12~5,000

Liquids, SlurriesHigh gas/solids content

Pipes

UNI,6526b-21UltrasonicDoppler

Log rate 5s –1 weekFlow/Depth/Temp

~5m/s -0~60Liquids, SlurriesOpen Channel

Logging SystemUNI,6526b-21LCDLog rate 5s –1 week

Flow/Depth/TempLCD display

HYS,OSSb1 propeller flow counter with field-computer

Stainless fanAdjustable depth

storage & download5m/s Water Current Measurements

Hydrology

GLO,FP101 propeller flow counterTelescopic handleVelocity averaging

Digital counter4.5m/s 5cm min

depthRivers & streams

Irrigation channels

110

FLOW M

ETERS

Page 121: 2007 Rentalsolutionsguide-Aunz Low

Panametrics PT878 Ultrasonic FlowmeterpAN,pT878 AU/MYportable non-contact liquid flowmeter using transit-time principle. Includes transducers for pipe 50mm~2mØ & temperatures -20~150OC (various alternative transducers available) with clamping fixture. Flow velocity range 0.03~12.2m/s. Accuracy typically 1%. Data logging for over 10K data points. Analog inputs compatible with temperature transmitters for energy-flow calculations. Outputs analog 4~20mA, digital (pulse or frequency) and printer/computer (Infrared port). Large LCD display for velocity, volumetric and energy flow rate, totalised flow and trend data in alphanumeric and graphical formats. Rechargeable NiMH batteries and ac power supply/charger.

GE Panametrics PT878 Flowmeter with NATA CertificationpAN,pT878-NATA AUSpecification as above but with NATA certification.Polysonics Hydra SX30 Dual Frequency Doppler Liquid FlowmeterpOL,HYDRA-Sx30 AUUltrasonic non-contact flowmeter. Velocity range 0.06~10m/s, accuracy ±1%. pipe size range 12mm~5mØ. Data logging for 90,000 points, with pC software and interface cable for download via RS232C interface. Transducer temperature range; -40~122OC. Analog output 4~20mA. battery operated, 12h continuous use [8h recharge].

Hydrological Services Universal Current Meter OSS-B1 HYS,OSSb1 AUWater current meter for measurement of flow velocity in rivers, streams, channels and open water. Robust streamlined stainless body fitted with high precision 100mmØ fan [flow range 0.025~5m/s]. Set of stainless wading rods for depths to 3m. Rechargeable “Hydromate” ruggedised field computer with Ip65 case. Storage of fan calibration formulae for direct readout of volume-flow. Touch screen entry for set up, input, storage and download. Supplied with PC download software and cable.

Panametrics 2-CH RTD TX for PT868/878 Energy CalcspAN,2CHRT-1-1 AUTwo channel 4~20mA RTD transmitter, range -20~130OC for energy rate and consumption measurements with pAN,pT868 or pAN,pT878 ultrasonic flowmeters. Provides supply and return temperatures for flowing liquid. panametrics cable and connector supplied. Fitted with pair of clamp-on Pt100 RTDs and cables. Powered from flowmeter.Panametrics 2-CH TX for PT868/878 Energy CalcspAN,2CHRT-1-2 AUTwo channel 4~20mA RTD transmitter, range -20~260OC for energy rate and consumption measurements with pAN,pT868 or pAN,pT878 ultrasonic flowmeters. Provides supply and return temperatures for flowing liquid. panametrics cable and connector supplied. Fitted with pair of clamp-on Pt100 RTDs and cables. Powered from flowmeter.

Unidata Open Channel Liquid Flow Logger with LCD moduleUNI,6526b-21LCD AUOpen channel flow logger with field LCD display module and 10 m cable (2m depth rating). Measurement and logging of flow-velocity (by Doppler), depth (by pressure) and temperature. programmable for flow-channel profile (laptop pC required for in-situ programming via RS232C). Operating temperature range 0~60OC. Velocity 21~5,000 mm/sec +/-2%; depth 0~2,000 mm +/-2%. Temperature: -17~60OC +/-0.1; log-interval 5 sec~1 week; memory 120k. programmable output to control devices such as water samplers. Detects and measures reverse flows. Charger and batteries supplied. Workhead dimensions 290 x 70 x 25mm.

Unidata Open Channel Liquid Flow LoggerUNI,6526b-21 AUOpen channel flow logger, programmed in-situ for flow-channel profile (laptop pC required). Measurement of flow-velocity (by Doppler), depth (by pressure) and temperature. Includes 10m cable. Memory 120k, RS232 interface. Log rate 5 sec~1 week. Operating temperature range 0~60OC. Velocity 21~5,000mm/sec +/-2% (resolution 1); depth 0~2,000mm +/-2% (resolution 2). Temperature: -17~60OC (resolution 0.1). Programmable output to control devices such as water samplers. Detects and measures reverse flows. Charger and batteries supplied. Workhead size 290 x 70 x 25mm.

flOW meterS - liquid

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 111

FLOW

MET

ERS

Page 122: 2007 Rentalsolutionsguide-Aunz Low

flOW meterS - gaS

Model Type Features Max Flow Temp°C

pipe Ømm

MajorApplication

SpI,VFM5000-50 Vortex 4 ~ 20mA outputFlow, Pressure, Temperature 600m3/h Supplied DN50 Air under pressure

Saturated steam

HOF,2000 & HOF,38 Turbine flowmeter Totalising recorder outputs ~200ACFM(50mm) 38mm or 50mm turbine Gases

SIE,S100-5 Mass-flow thermal sensor

“Dial-A-Gas” for 10 gasesRS232C, Analog outputs 5slpm ¼” (at meter) Low – flow gases

KUR,2443-24 Thermal mass-flow insertion meter

Cold tap fittings, RS232CLogging, 4 ~ 20mA output 12,000sfpm -40~200 50mm~ Gases

pVL,CLIMA3 Insertionmicro-turbine

Hot-tap rigRS232, Pressure transducer 40m/s -20~80 ~150mm

(450mm without hot-tap) Compressed air

TSI,4143-6 Mass-flow thermal sensor

Temp measurementRS232C, Mains/battery 0.01~20slpm

0~50In-line 9.5mm Clean air flow

Use as calibrator

TSI,4040-6 Mass-flow thermal sensor

Temp measurementRS232C, Mains/battery ~300slpm In-line 22mm ISO Clean air flow

Use as calibrator

ClimaAir 3 Flow Meter for Compressed Air & GasespVL,CLIMA3 AUPortable gas flowmeter for compressed air and other applications. Fitted with “Combisensor” insertion probe for simultaneous measurement of flow, pressure and temperature. Measuring ranges flow 0.06~40m/s, pressure to 15bar, temperature to -20~80ºC. Supplied with valve and adaptor-kit for hot-tapped pipes approx 25~150mm ID, and fitting-kit for pipes to 450mm. Flow computer functions include flow correction, volume-calculation, and data logging for about 15,000 values. With RS232 interface and cable, and software for data download. Rechargeable with AC adaptor.

Sierra Series 100 Gas Mass-flowmeter 0~5l/minSIE,S100-5 AUSmart-Trak mass flowmeter. Digital display of mass flow rate for gases in the range 0~5l/min. Dial-A-Gas set up for direct readout of flow for 10 different common gases without adjustment or recalibration. Analog and serial RS232 ports, with software and cable provided for connection to PC. Portable configuration with case, battery, ac power supply and flexible gas connection set.Portable Mass Flowmeter & Calibrator 0~300 SLPMTSI,4040-6 AUThermal mass flowmeter or field calibrator for operation in the range 0~300SLpM (standard litres/min). LCD display for flow, temperature and pressure . Suitable for flow measurements on clean air, or for calibration checks on personal sampling pumps. Accuracy ±2%/0.05SLpM [whichever is greater] for air or oxygen [±3%/0.10SLpM for nitrogen or air-mixtures]. Operating pressure range 50-199kpa absolute [approx 95kpa gauge]. With HEpA filter, adaptor and tubing. RS232C/analog connector with cables supplied. AC adaptor or battery operation.

Portable Mass Flowmeter & Calibrator 0.01~20 SLPMTSI,4143-6 AUThermal mass flowmeter or field calibrator for operation in the range 0.01~20SLpM (standard litres/min). LCD display for flow, temperature and pressure . For flow measurements on clean air, or for calibration checks on personal sampling pumps. Accuracy ±2%/0.005SLpM [whichever is greater] for air or oxygen (±3%/0.010SLpM for nitrogen or air-mixtures). Operating pressure range 50-199kpa absolute [approx 95kpa gauge]. With HEpA filter, adaptors and tubing. RS232C/analog connector with cables supplied. AC adaptor or battery operation.Hoffer 2000 Gas Flow Meter IndicatorHOF,2000 AUFlow indicator/totalizer for use with flow transducers. Digital display with recorder outputs 0~10V, 4~20mA. RS232C interface. Operates from ac mains. Display of metric units with optional conversion factor.Hoffer 38mm Gas Flow Turbine/TransducerHOF,38 AU38mm MS flared gas flow turbine/transducer for use with HOF,2000. Volumetric flow rate range 1.75~120 actual cfm - gas type, pressure and temperature correction may be used for mass flow units such as SCFM, kg/min or L/s. Supplied with 38mm Table E Flanges. Approach pipe length 380mm, exit pipe length 190mm.Kurz 2443 Air Velocity MeterKUR,2443-24 AUportable air velocity meter and flow-computer. Velocity range 0~12,000sf/min (60m/s) at pressures to approx 10bar (probe rated to 20bar). Temperature range -40~200OC with compensation. User selected English or metric units for velocity or mass-flow. Thermal sensor probe 9.5mmØ & 330mm long with sensor-shield, with compression fitting and nylon ferrules for probe removal or position adjustment in tapped pipe. Suitable for use in ducts or pipes, min pipe 50Ømm. Calibrated for air, and suitable for use with other non-hazardous gases. Recording of up to 1,500 data sets with time and date. Two analog 4~20mA outputs, and RS232C serial port for configuration upload and data download. Rechargeable NiMH batteries.

112

FLOW M

ETERS

Page 123: 2007 Rentalsolutionsguide-Aunz Low

air flOW meaSurement/air quality

Model Type Air Velocitym/s

Flowl/s

Max Temp OC Pressure Functions Notes

SHO,CFM88-3Balometer

12~944TSI,8373

15~1,000 60

Logging

TSI,8370

TSI,8371

TSI,8375 Accubalance modular air balancing tool

0.13~41depending on

probe11~1,000 ±3735Pa diff

135 kpa abs LoggingHoodPitot

Velocity Matrix

AIR,EDM2500

Manometer (electronic)

~14~28

125 Pa500 Pa

2,500 PaRecorder output

DRU,DpI7050~20 kpa Analog output

HAL,EMA150

SHO,ADM-860 ~50 0.025~14,700pa With Velgrid

TSI,8704 1.25~78.5 -1245~3735pa LoggingRS232C

AIR,DM2

Manometer (digital)

±200kpa Recorder output

DPM,TT370S 1.2~100

pressure:199.9Pa1999Pa7.0kpa

Without Pitot tube

DPM,TT570CL 10~100 10~100

pressure:99.9Pa999Pa7.0kpa

LoggingRS232C

TSI,8704

Differential Micro-manometer

1.27~78.5 -1245~3735paExtendable Pitot Tube

TSI,8705 Pitot Tube

TSI,8710 10~100 3735PaStatic TipPitot Tube

Velocity Matrix

TSI,8345

Anemometer (hot wire)

0.15~3093

TSI,8355 0.15~50

TSI,8384 0.1~50 60

TSI,8324

Anemometer(vane, 100 mm) 0.25~30

80Logging

Max, Min & Sweep

Articulated telescopic extension

AIR,AV270 Analog output

LoggingRS232C

NATA version available

AIR,AV6

SCH,MINI-2 Anemometer(vane, 22 mm) 0.3~40

TES,450 Anemometer(vane, 16mm)

0.4~40 130Results

averagingMin/Max display

Telescopic probe

TES,445 0.4~60 140 LoggingMa, Min & Mean Micro-vane probe

AIR,UA6Anemometer (ultrasonic)

0~5070 Logging

RS232C

Low flow turbulence

AIR,UA30 0~30 Low flow turbulenceReads to 0.001 m/s

HOB,PRES Pressure logger 75 500~110,000paLogging

KUR,2443-24 Air Velocity Meter 0~60 200 10*/20bar Flow – computerWith pipe-fittings*

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 113

AIR

COND

ITIO

NING

& A

IR Q

UALI

TY -

HVAC

& IA

Q

Page 124: 2007 Rentalsolutionsguide-Aunz Low

Model Type TempOC RH% CO

ppmCO2ppm

NOppm Dust & Aerosol Notes

TSI,8520Particle measurement

0.001~100mg/m3

0.1~10µLogging

TSI,8520-1 Outdoor enclosureAbA,301 0.3~5µ

LoggingTSI,8525 Ultra fine particle

measurement0.01 ~ 5x105 particles/cm3

0.02~1µ

TSI,8386A Multifunction air quality meter 60 5~95 Logging, Wet bulb

Dew point, Differential pressureTSI,8551 Indoor air quality monitor

(multi-function) 50 5~95 500 5,000 LoggingRS232C/SoftwareTSI,8554

YES,205-5 Multifunction air quality logger 50 5~95 200 10,000 300 Logging

TES,645-1Humidity & dewpoint meter 120 2~98 Robust stainless probe

TES,645-2

CAS,MICROTHERM Area heat stress monitor * *WBGT index, RH + Dewpoint

*Air temp to 60º, Wet temp to 40ºGlobe temp to 120º

air flOW meaSurement/air quality

Portable Smoke Generating MachineCSS,COLT4 AUportable smoke generator with variable smoke emission rate. Suitable for air flow visualisation, HVAC ductwork leak-testing, fire training and general work. pump-free operation with smoke fluid supplied from consumable aerosol cans or refillable containers [pump supplied for pressurisation]. Manual or continuous operation and off-power facility. Maximum output 31 cubic meters/min at 1.5m visibility. Operation for 18min from one can at maximum capacity.

Airflow EDM2500 Electronic Manometer 0~2500 PaAIR,EDM2500 AU/NZpressure ranges 125, 500 & 2,500pa. Air velocity measurement using pitot-static tube with ranges 14 & 28m/s. Supplied complete with pitot static tube, balancing valve, and tubing. Fitted with 1mA fsd recorder output. battery operated.Airflow DM2 Medium Pressure ManometerAIR,DM2 NZHandheld medium pressure digital manometer. Suitable for positive, negative and differential pressure measuements. Displays readings in mBar, kpa & psi. Ranges are ±2,000mbar, 200kpa & 29.99psi. Resolution is 1 or 0.1mbar & 0.1 or 0.01kpa. Accuracy on all ranges is 0.5% of reading. Serial interface for uploading stored results. Maximum stored readings during logging is 700. Analogue output of ±1V at 0.5mV per mbar.

>NEW TSI 8710 DP-CALC Differential Micro-Manometer

TSI,8710 AUMicro-manometer for static or differential pressure, velocity, volumetric flow, atmospheric pressure and temperature. With statistical analysis, density correction, K factor and automatic actual/standard flow calculation. Differential pressure range ±3735pa. Velocity display to 78m/s (range depends on probe). Supplied with static tip, Pitot tube, velocity matrix and temperature probe. Datalogging (1,000 point) with RS232C interface and software. Rechargeable cells or AC adaptor.

>NEW TSI 8705 DP-CALC Differential Micro-Manometer

TSI,8705 AUDifferential micro-manometer measuring differential pressure, velocity, average, volumetric flow, maximum and minimum. With static pressure calculations, density correction and K factor. pressure range -1245~3735pa. Velocity range 1.27~78.5m/s. Supplied with 200~980mm telescopic pitot tube. Datalogging (1000 point) with RS232C interface and software. Battery powered.

114

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ

Page 125: 2007 Rentalsolutionsguide-Aunz Low

air flOW meaSurement/air qualityTSI 8704 DPCALC Micro ManometerTSI,8704 AUMeasures differential pressure, velocity, average, volumetric flow, max & min. With static pressure calculations, density correction and K factor. Pressure range -1245~3735pa. Velocity range 1.25~78.5m/s. Extendable pitot tube 20~980mm. Datalogging 500 point with RS232C interface and software.DPM TT370S Digital ManometerDPM,TT370S NZDigital micromanometer with an extendable pitot tube kit. Dp ranges are 199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s. Dp accuracy is 1% of reading +2 counts. Recorder output of 1mV per count.DPM TT570CL Digital Manometer NATA CertificationDpM,TT570CL-NATA NZDigital micromanometer with an extendable pitot tube kit. Dp ranges are 199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s. Dp accuracy is 1% of reading +2 counts. built-in data logger holds 1,400 readings.Druck DP1705 Manometer 0~20 kPaDRU,DpI705 AUHandheld digital manometer range 0~20kpa, accuracy 0.2 %. Displays all common engineering units.Shortridge ADM-860 Electronic ManometerSHO,ADM-860 AU/MYElectronic micro manometer for air balance and similar applications. Measures differential pressure, air velocity and temperature. Differential pressure range 0.0025~1,500mm wg. Velocity range 7.5~3,000m/min (750m/min with velgrid). Memory 100 point with sum and average. Accessories include pitot tube and 16 point velgrid for face velocity work including exhaust hoods, clean room outlets, and large filters or coils.Airflow 36 Pitot TubeAIR,pITOT-36 AUpitot tube (36”) for use with manometers and micro manometers.Kurz 2443 Air Velocity MeterKUR,2443-24 AUportable air velocity meter and flow-computer. Working velocity range 0~12,000 sf/m (60m/s) at pressures to approx 10bar (probe rated to 20bar). Temperature range -40~200OC with compensation. Selectable English or metric units for velocity or mass-flow. Thermal sensor probe 9.5mmØ x 330mm long with sensor-shield. Compression fitting and nylon ferrules for probe removal or position adjustment in tapped pipe. Suitable for use in ducts or pipes, min pipe 50mmØ approx. Calibrated for air and suitable for use with other non-hazardous gases. Recording of up to 1,500 data sets with time and date. Two analog 4~20mA outputs, and RS232C serial port for configuration upload and data download. Rechargeable NiMH batteries.

TSI 8370 Accubalance BalometerTSI,8370 MYbalometer including 5-hood kit and hard case. Flow range 15~1,000 litres/sec (50 to 3,500m3/hr) accuracy +/-5%, reading +/- 2.4 l/s (8.5m3/hr). Operating temp range 0-60OC. Weight (610 x 610mm hood) 3.4 kg hood provided 610 x610mm (standard), 610 x 1220mm, 305 x 1220mm, 305 x 1525mm and 915 x 915mm.

TSI 8371 Accubalance BalometerTSI,8371 NZAirflow hood 610 x 610mm. Measures air volume flowing through registers, diffusers, and grilles. Range is 15~1,000l/s, accuracy is ±5%. Temperature range is 0~60ºC. Sample and hold function displays reading of one sample. Automatic conversion between actual and standard flows when user initially inputs temperature and barometric pressure, variable time constant modes available for a steady display when measuring fluctuating flows, K factor function enables flexibility for measuring a variety of diffusers, back-lit display is easy to read in poor lighting conditions.TSI 8373 Balometer With LoggingTSI,8373 AUFlow range 15~1,000L/s (50~3,500m3/hr); accuracy ±5% [to ±2.4L/s]. Operating temperature range 0~60OC. Includes 5 hood kit & hard case. Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm, 305 x 1,525mm & 915 x 915mm.TSI 8375 Accubalance Modular Air BalancingTSI,8375 (NZ)Balometer with detachable micromanometer for air balancing applications. 610 x 610mm air capture hood for measurements in the range 42~4,250m3/h with automatic compensation for barometric pressure and air temperature, 450mm pitot probe (range 0.13~41m/s), 16-point velocity matrix probe (0.13~13m/s) and static pressure probes (differential pressure range ±3,735pa with safe limit 37kpa, absolute pressure range 47~135kpa). Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit LCD display for single or statistical readings with min, max and average of up to 1,000 values of each measured parameter. Manual result storage or automatic data logging up to 1,000 time/date stamped readings. RS232 port for data transfer to pC or serial printer, with cable and “LogDat” download software. Rechargeable with approx 12h operation, or ac adaptor.Shortridge CFM88-3 Electronic BalometerSHO,CFM88-3 AUMeasures supply and exhaust flow in cfm and l/sec. Ranges 25~2500cfm supply and 25~1500cfm exhaust. Compensated for air density and back pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.Airflow AV2 100mmØ Anemometer with Volume displayAIR,AV2 AU/NZVane anemometer with 900mm (35”) telescopic probe extension. Velocity measurement range 0.25~30m/s (50~6,000ft/min). Averaging mode available. Volume display based on duct or other area. Head operating range -10~70OC (lower limit of -30CC for short periods). Output 0~1V.

Airflow AV2 100mmØ Anemometer NATA CertificationAIR,AV2-NATA AUSpecification as above but with NATA certification.Airflow AV6 100mmØ Anemometer with VolumeAIR,AV6 NZVane anemometer 100mmØ with articulating extension handle. Measures velocity, volume flow and temperature. Vane head operating range is -10~70ºC, -30 possible for short periods. Accuracy is ±1% of reading +1 digit. Resolution is 0.01 m/sec. Velocity range is 0.25~30m/s. RS-232C interface for data logging & real time data retrieval. Stores up to 99 readings of velocity & temperature. Analogue output of 0~1v.Schilknecht Mini Air 2 Vane AnemometerSCH,MINI-2 AUprobe 22mmØ. Range 0.3~40m/s. Min, max & time averaging functions with 0~1V analog output.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 115

AIR

COND

ITIO

NING

& A

IR Q

UALI

TY -

HVAC

& IA

Q

Page 126: 2007 Rentalsolutionsguide-Aunz Low

air flOW meaSurement/air quality

>NEW Testo 445 Vane Anemometer with 16mm vane

TES,445 AUMicro-vane probe. Simultaneous digital display of air velocity and temperature, with continuous-update, max, min & mean functions. Volume-flow option with entry of duct dimensions .Telescope mounted metal probe, vane 16mmØ. Operating range 0.4~60 m/sec, accuracy ±0.2m/s, ±1%mv up to 40m/sec. Temperature range -30~140ºC for short-term measurements. Selectable site-locations, and 3,000 point internal memory for manual saving or automatic data logging. Battery powered.

Testo 450 Vane Anemometer with 16mm VaneTES,450 AUAnemometer with micro-vane probe. Digital display of air velocity and temperature. Telescope mounted metal probe, diameter 16mm. Operating range 0.4~40m/s ±0.2 and to 60m/s ±unspec. Temperature range -30~140OC for short-term measurements. battery powered.

TSI 8345 Hot Wire AnemometerTSI,8345 AUThermal anemometer range 0.15~30m/s; accuracy ±3%; volumetric flow display; averaging capability up to 255 readings. Probe operating temperature range -17.8~93.3OC. probe 98mm long x 6mmØ at tip. Digital display. RS232C printer interface. Battery or mains operation.

TSI 8355 Hot Wire AnemometerTSI,8355 MYRange 0.15~50m/s. probe will operate over a temp range of -17.8~93.3ºC. Digital display with averaging capability o up to 255 reading. Temperature measurement range -17.8~+93.3 C RS 232 printer interface. battery & AC operation.TSI 8384 Hot Wire AnemometerTSI,8384 NZHandheld hot wire anemometer. Velocity range is 0.1~50m/sec, accuracy is ±3% of reading or ±0.015m/s whichever is greater. Resolution is 0.01 m/s. probe temperature range is -10~60ºC and 0~80%RH. Stores 1,394 samples of velocity, volumetric flow-rate and temperature with time and date stamping. Data can uploaded to a pC or printed. Supplied with 10mmØ x 1m telescopic probe.

>NEW TSI 8324 VelociCalc 100mm Vane Anemometer with Volume Display

TSI,8324 AU Vane anemometer with 100mm head, supplied with handle and 900 mm articulated telescopic extension. Velocity measurement range 0.25~30 m/s ±1%; temperature measurement range 0~80ºC ±0.5 ºC. Volume display range 0~4.36x106m3/h with input for circular or rectangular duct dimensions. Variable time-constant; sample statistics average, max and min; and “sweep” mode for extended continuous sampling. Internal memory for single point measurements or time-based data logging, for up to 2849 samples and 1000 test IDs, with serial interface, cable and software for data download. Direct data acquisition [polling] from PC terminal modes. Battery powered with auto-power-off, and optional AC adaptor.

TSI 8386A VelociCalc Air Conditioning Efficiency MeterTSI,8386A AUportable efficiency measurement system for HVAC and related work, with hot wire anemometer, static and differential pressure, temperature and humidity measurement with heat flow efficiency calculation. Velocity (hot wire) 0~50m/s, accuracy ±3.0%. Temperature -10~60OC, accuracy ±0.3. Wet bulb temperature 5~60OC. Relative humidity 0~95%RH, accuracy ±3%. Dewpoint -15~49OC. Static/differential pressure -1,245~3,735pa, accuracy ±1%. probe length 100cm, tip diameter 7mm, base diameter 10mm. Includes data logging and printing. Battery operated.Airflow UA30 High Resolution Ultrasonic Anemometer 0~30m/sAIR,UA30 AU/NZprecision anemometer range 0~30m/s, accuracy better than 1% of reading, resolution 0.001m/s, non-directional. Temperature range 0~70OC, accuracy 1OC, resolution 0.1OC. Flow turbulence range 0~99%. Capable of measuring very low air velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up to 99 readings of velocity, temperature and turbulence, intervals 1s~99min. RS232C interface. Operates for 20h on alkaline batteries.

Airflow Ultrasonic Anemometer 0~50m/s AIR,UA6 AURange 0~50m/s, accuracy better than 1% of reading, resolution 0.01m/s, non-directional. Temperature range 0~70OC, accuracy 1OC, resolution 0.1OC. Flow turbulence range 0~99%. Capable of measuring very low air velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up to 99 readings of velocity, temperature & turbulence, intervals 5s~99min. RS232C interface. Operates for 20h on alkaline batteries.

116

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ

Page 127: 2007 Rentalsolutionsguide-Aunz Low

>NEWTesto 635-2 Humidity, Temperature & Dewpoint Meter

TES,635-2 AUportable humidity meter fitted with robust stainless probe with sintered filter-cap for general or duct measurements to 120ºC, and fast-action K-type surface temperature probe. Displays relative humidity, absolute humidity, dew point, degree of humidity, enthalpy, temperature, and differential temperature (dewpoint~surface). Operating range 2~98%RH (±2%). Air temperature -20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1). Internal memory for 10,000 values with USb interface, cable and software for download and presentation. Battery operated.

Testo 635 Humidity & Dewpoint MeterTES,635 NZ/MYTemperature, humidity and dew point meter. Probe temperature range is -20~70ºC. Humidity range is 0~100%RH resolution: 0.1%, accuracy is ±2%. Dew point range is -50~40ºC.Testo 645 Humidity & Dewpoint MeterTES,645-1 AUportable humidity meter fitted with robust stainless probe for ambient work or duct measurements to 120OC. Displays relative humidity, absolute humidity, dew point, degree of humidity, enthalpy and temperature. Operating range 2~98%RH [±2%], -20~120OC [±0.4/0.5]. battery operated.Abacus Hand-held Airborne Particle CounterAbA,301 AUPortable particle measuring system typically used in clean room applications. 4 x fixed size channels 0.3, 0.5, 1.0 & 5.0micron. Count data automatically stored in a 500 sample memory which can be downloaded to a PC. Selectable sample time. Includes zero count filter for checking backgrounds. When used with included software will check clean rooms to ISO 14644 and BS5295 requirements. Battery operated.Vaisala WAA151 Wind Speed/Direction TransducerVAI,WAA151 AURange 0.4~75m/s. Current output with selectable ranges including 4~20mA & 0~20mA. Requires indicator module such as DE,DT600 datalogger for indication of windspeed and direction.TSI 8551 Indoor Air Quality Monitor with Logging TSI,8551 AUMeasures temperature, humidity, CO & CO2 concentrations. Humidity 5~95%RH, CO 0~500ppm, CO2 0~5,000 ppm. Internal logging up to 63,000 data points; interval adjustable 1s~1h; RS232C interface and software included. Battery or mains operation.

TSI Q-Trak plus Indoor Air Quality Monitor with Logging TSI,8554 AU/NZIndoor air quality (IAQ) monitor for temperature and humidity measurements, CO and CO2 concentrations. Humidity range 0~95%, temperature range 0~50OC. Electrochemical cell for CO 0~500ppm. NDIR cell for CO2 0~5000ppm. Data logging for 48,671 data points with interval adjustable 1s~1h. Fitted with RS232 interface, and software included for download, storage and reporting. Battery or mains operation with ac adaptor.

YES 205-5 Indoor Air Quality Monitor with LoggingYES,205-5 AU5 channels for temperature, humidity, CO2, CO & NO. Temperature range 0~50OC, resolution 0.1, accuracy ±0.5. Humidity 5~95 %RH, accuracy ±2%. CO2 0~10,000 ppm, resolution 0.5ppm. CO 0~200 ppm, resolution 0.5ppm. NO 0~300 ppm, resolution 0.5ppm. Logging of CO and NO allows checking of indoor air for contamination by vehicle emissions from nearby carparks, loading docks etc. Includes interface and software. Mains/battery operation.Casella Microtherm WBGT Area Heat Stress Monitor CAS,MICROTHERM AUportable area heat stress WbGT monitor with real-time graphical display. Measures heat stress potential [WbGT index] according to ISO7243. pRTD sensors with internal calibration-reference for wet-bulb, dry-bulb and globe temperatures. Large LCD display for numerical or graphical indication of temperatures and processed values for WbGT [indoor/outdoor plus TWA], relative humidity and dewpoint. Simple keypad/menu setup. Data logging for up to 32 separate runs and 49,100 records, with interval 30s~1h. RS232C port with included PC software for download and reporting or realtime display. Low water-level warning, and settable audible/visible WbGT alarm. Handheld, free-standing or tripod-mount. battery operated.TSI 8520 DustTrak Airborne Particle MonitorTSI,8520 AU/NZPortable aerosol monitor. Laser photometer with 90O scattering detection, Range: 0.001~100mg/m3 [Calibrated for A1 test dust, ISO 121203-1], resolution: 1% of reading or 0.001; particle size range: 0.1~10µm. Internal pump flow rate 1.4~2.4L/min (1.7 nominal). Data logging 30,000 data points (21d @ 1min), log interval: 1s~1h. RS232C interface and software included. Battery operated.TSI 8520-1 Environmental Enclosure for DustTrakTSI,8520-1 AUWeatherproof outdoor housing for TSI,8520 aerosol monitor. Rugged case with tripod mount, fitted with sample inlet and water trap. Includes extended-life battery pack and charger/adaptor.TSI 8525 P-Trak Ultrafine Particle CounterTSI,8525 AURange 0.01~5 x 105 particles/cm3. particle size range 0.02 to greater than 1micron. Includes PC software and cable. Suitable for detection of ultrafine particles associated with pollutants. Battery powered [8h operation using alkaline batteries].

air flOW meaSurement/air quality

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 117

AIR

COND

ITIO

NING

& A

IR Q

UALI

TY -

HVAC

& IA

Q

Page 128: 2007 Rentalsolutionsguide-Aunz Low

Haloteck Refrigerant Gas Leak DetectorHAL,78000 AUFor use by refrigeration engineers. Rapid response 0.2s, audio output, zero warm up time. Single control, battery operated, sensor tip insensitive to draughts. Sensitivity better than 3g/y R12, 25g/y R134A. Responds to halogenated hydrocarbons and many fire extinguishant gases, [also sulphur hexafluoride SF6]. Battery life 30h. Duty cycle continuous. Probe length 240mm. Weight 280g.Bacarach Leakator 10 Combustible Gas Leak DetectorbAC,LEAK10 AUFlexible probe with solid-state sensor for rapid area checks and pinpointing of large or small leaks. Sensitive to combustible vapours including common solvents, and gases including natural gas. Adjustable sensitivity with detection limit approximately 20ppm [methane]. Indication by ultra-bright LEDs and audible speaker. battery powered.

GasCheck 3000 Portable General-purpose Leak DetectorION,GASCHECK3000 AUMicro thermal-conductivity sensor for high-sensitivity detection of gases with a thermal conductivity different to that of air, including helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups. Direct reading of leak rate in ml/sec with audio and visible signals. Detection limit for helium 2E-5ml/s. battery powered.

air cOnditiOning balancing inStrumentS

>NEW Testo 560-2 Electronic Manifold for Refrigeration Testing

TES,560-2 AUThree-way valve bank, for commissioning, maintenance and repair of refrigeration systems. Stainless-steel block for use with common pressure media including CFC, FC, N, CO2 and ammonia; with stored data (including saturation properties) on 36 refrigerants. Measurement of vacuum (0~200hpa), pressure (0-50bar), ambient [case] temperature for compensation (-10~50ºC) and system temperature (-100~400ºC instrument range; supplied with pipe-wrap probe 0~120ºC). Calculations for absolute/relative pressure, vacuum drying-efficiency, system cooling/heating capacity, leakage testing, superheating or sub-cooling values. Data storage, or interval-logging up to 100,000 readings, with serial interface and software for download, analysis and documentation. battery or AC adaptor powered.

Tour & Anderson CBI Balancing MeterTA,CbI AUDigital pressure balancing instrument with LCD display. For cooling water valve balancing in air conditioning plants and similar applications. Firmware revision 3A. Includes facility for entry of Kv value to allow balancing of all hydronic valve types. Differential pressure range -0.5~20.5m water gauge at a total pressure of less than 200m. Resolution 0.001m. Flow resolution 0.001L/s. battery operated.

118

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ

leakage detectOrS

>NEW Environdata WeatherOne Wind Speed & Direction Logger

ENV,DL20WSD AULogging system for wind speed and direction. Tripod-mounted cross-arm stand with 3-cup windspeed sensor range 0-75m/s and independent vane direction sensor. Sealed dual-channel logger with memory for 35,000 readings with time and date, fitted with backup battery, rechargeable sealed main battery and solar panel for in-field recharge. power supply for charging or operation from mains supply. “EasiAccess” software on CD for office or field connection via RS232C compatible computer (not included), for set-up, download and real-time operation, with functions for tabular or graphical display.

Environdata WeatherMaster 2000 Weather StationENV,WM20 AUMeasures air temperature -15~50OC ±0.2, relative humidity 10~90%RH ±5%, rainfall 0.2mm resolution. Wind speed starting threshold 1kph. Wind direction resolution 6O ±3%. One spare input channel. Capable of storing up to 3mths of data. Includes RS232 interface and software for download. Mounts on star-picket. Solar-rechargeable batteries.

Weather StatiOnS

Page 129: 2007 Rentalsolutionsguide-Aunz Low

Hioki Lux HiTester Digital Illuminance MeterHIO,3423 AU/MY/NZHIO,3423-NATA NZManual switching and autoranging. LCD display with 3½ digits (“1999”) for five measuring ranges to 20/200/2000lx in 1-count steps, 20,000lx in 10-count steps and 200,000lx in 100-count steps with accuracy ±4%. Response time in autorange mode 5sec (2sec in manual range mode). Autozero, hold and backlight function with delay for taking readings in low light. Input for ac power adaptor, connecting-cable to allow separation of sensor unit and meter, and 200mVdc analog output with cable. Battery powered.

Extech Digital Light Meter NataExT,407026 NZNATA calibrated portable digital light meter. Ranges; 2,000, 20,000 & 50,000 lux. Accuracy is ±4%. Displays in foot candles or lux for tungsten, daylight, fluorescent, sodium or mercury lamps. Data logging of measured values, Min/Max & Average, software and serial interface for uploading results.Minolta T-1 Lux MeterMIN,T-1 NZMicroprocessor controlled digital light meter. Measuring time can be adjusted for accurate readings of both continuous and flickering light sources. Illuminance deviation between sources can also be determined, or integrated illuminance over a period of time can be calculated. Range is 0.01~99,900lx. Accuracy is ±2%.ILI 1400ABC Radiometer for UV MeasurementsILI,1400AbC AUInternational Light model 1400 radiometer with backlit LCD display, autozero and autoranging. Continuous reading with hold function, or integrated “dose” measurement up to 24h. Smart detectors with storage of units and detector-calibration data. Analogue recorder output. Mains adaptor or battery power. Supplied with three sensors: UV actinic hazard (UVC with b & A components matched to OSHA requirements), range 2.50e-7 to 2.50e-3 W/cm2 eff. UVb + A (total “solar” radiation), range 1.16e-7 to 4.07e-1 W/cm2. UVb, range 1.54e-6 to 1.54e-2 W/cm2.

Minolta CL-200 Chroma Meter for illuminance & Colour Measurement MIN,CL200 AUKonica Minolta model CL-200 portable colour meter. LCD display for illuminance, tristimulus values, chromaticity, correlated colour temperature and colour difference. Illuminance range 0.1~99,990lx ±2%. Colour accuracy ±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface. battery powered, or AC adapter.

Topcon BM-9 Luminance MeterTOp,bM-9-2 AUportable luminance meter with digital display. Field-of-view 5O, measurement acceptance angle 2O, with 10mm min spot diameter. Measuring distance 0.35m to infinity. Silicon photodiode sensor with automatic or manual range selection. Measurement range 0.01~199,900cd/m2 ±4% of reading. built-in RS232C interface and analogue output. Battery powered.Topcon IM-2D Digital LuxmeterTOp,IM-2D AUDigital illuminance meter. Measuring range from 0.1~19,999lx. Accuracy ±5%, +1 digit. Autoranging with silicon sensor. battery operated.Topcon IM-2D Lux Meter NATA CertificationTOp,IM-2D-NATA AUDigital illuminance meter with NATA certification. Measuring range from 0.1~19,999lx. Accuracy 5%, ±1 digit. Autoranging with silicon sensor. Battery operated.

Topcon IM-5 Lux Meter NATA CertificationTOp,IM-5-NATA AUDigital wide-range illuminance meter with NATA certification. Measuring range 0.01~199,000lx. Accuracy ±2% +1 digit. Autoranging with silicon sensor. Analog output and RS232 interface. battery operated.

light & uv meaSurement

HP35660A 100kHz Dual Channel Spectrum AnalyserHp,35660A AU401 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal sources: fixed sine, random noise, chirp. built-in disk drive. HpIb plotter interface. bandwidth is 102.4kHz for single channel measurements and 51.2kHz for dual channel measurements.

SOund Signal analySiS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 119

OCCU

PATI

ONAL

HEA

LTH

& SA

FETY

Page 130: 2007 Rentalsolutionsguide-Aunz Low

nOiSe & SOund analySerS

>NEW ARL EL-316 Environmental Noise Logger Type 1

ARL,EL-316 AUEnvironmental noise logger with display for field-reading of summary results. portable, self-contained and weatherproof. Type 1 performance, continuous 90db dynamic range, fast response, frequency weightings A and C. Monitors environmental noise continuously for up to 3 weeks, calculates and stores over 7500 sets of Ln indices. PC required to set up system and download data using software supplied. Set up also possible from front-panel.

>NEW Ivie IE-35 Type 1 Audio Analysis Systems

IVI,IE35-2p AUAudio Analyser with Dell Axim x51v pDA. Fitted with half-inch free-field Type 1 microphone and pre-amplifier. Functions include SpL (sound level), Real-time analysis, “seat-to-seat” variation for audio setup, reverberation measurement, “strip-chart” recording on display, voltage and oscilloscope displays and signal generation. Supplied with field-calibrator, microphone extension cable, spare battery and software for data-download to pC. SpL facilities include time and frequency weightings - fast, slow, peak or impulse and A, C or Flat. FFT based Real Time Analysis includes 1/1, 1/3, or 1/6 octave bands with a maximum resolution of about 1/24 octave. Additional functions include spectrum subtraction, averaging, Noise Critera or Reduction contours and reverberation-decay to ISO-20 and ISO-30. Signal-generation includes sine, square, triangle and white or pink noise.

Model Description Type/Class Features RS232C Major ApplicationsbK,4443 Noise dosemeter (2) built-in set up routines, 53,000 values

Yes

OH&S

bK,2237A

Sound level meter

2

40 data records, ac output

OH&SGeneral

bK,2237A-NATA NATA certificate, ac output

RIO,NL-04 ac & dc outputs

RIO,NL05 Recorder outputs

QUE,2400 ac & dc outputs General

bK,2239A-NATA

1

NATA certificate, ac output YesOH&S

GeneralRIO,NL-11Fp Octave filter,printer

RIO,NL14 1/1 octave filter, ac & dc outputs Yes

RIO,NL14-NATA 1/1, 1/3 octave filter, NATA certificate

OH&SGeneralAnalysis

RIO,NL31 1/1, 1/3 octave filter

RIO,NL-32RTA-NATANATA certificate, Data loggingRealtime frequency analysis(1/1, 1/3 octave), “Flashcard”

bK,2238E-NATAEnhanced sound level meter firmware

Data logging, Frequency analysisNATA certificate

Yes

BK,7815 Software n/a Compatible with bK4443, 2239A, 2238E-NATA n/a Advanced applications

ARL,EL-215

Environmental noise logger

22,048 data sets, Weatherproof

Yes Long term outdoor logging

ARL,EL-315 7,500 data sets, DisplayWeatherproof

ARL,EL-3161

7,500 data sets, DisplayWeatherproof

bK,2238NMT-KIT 25MB memory, WeatherproofWith sound level meter

IVI,IE35-2p Audio Analysis System 1 Includes pDA, real time analysis, FFT, signal

generation, reverb, “seat-to-seat”, pC downloadGeneral Analysis

Engineering, Audiovisual

120

OCCUPATIONAL HEALTH & SAFETY

Page 131: 2007 Rentalsolutionsguide-Aunz Low

B&K Noise Monitoring Terminal with model 2238F SLMbK,2238NMT-KIT AUNoise logging system with B&K model 2238F Class 1 Sound Level Meter equipped with internal software for Basic SLM and Logging. Portable, wheeled weatherproof case. Standard SLM operation for fast, slow and impulse time weighings and A, C or linear frequency weightings RMS. Linear or C frequency weightings for peak detection. Internal memory 2Mb total for logging up to 12 parameters including auxiliary signals. Fitted with serial RS232 interface, and provided with bKlink software for download of logged data to pC. Supplied with field calibrator, charger and 12V, 18Ah battery, for operation for up to 14d logging at 15min intervals.

B&K 4443 Noise Dose Meter with LoggingbK,4443 AU/NZFitted with remote microphone, for OH&S surveys. Logging of 1 or 2 parameters from a range of 6, with variable interval. 4 built-in and 3 user-defined setup routines, 5 selectable statistical levels Lx. Storage of up to 53,000 values over 16 measurement periods, and download [or setup] via PC using software provided. Supplied complete with field calibrator. Battery powered.B&K 2237A Type 2 Integrating Sound Level MeterbK,2237A AUMeasures RMS and peak simultaneously. Linearly weighted analogue output for sound recording, 0~0.5V ac (rms). Measurement range 30~140db. Time weightings fast, slow & impulse. Independent frequency weightings A [for RMS readings SpL, MaxL, MinL, Leq, Inst] and C [for peak readings peak and Maxp]. Real time clock for time and date stamp. Records 40 measurements for download to PC. Calibrator included. Battery operated.Quest 2400 Type 2 Sound Sound Level MeterQUE,2400 NZType 2 sound level meter with LCD display for sound pressure level (SPL) or maximum level (MAx). Frequency weightings A & C, time weightings Fast and Slow. Ranges 30~140dbA and 40~140dbC with overload indication. AC & dc outputs. Battery powered.Rion NL-04 Sound Level MeterRIO,NL-04 MYMeets IEC type 2. Five measurement functions: Lp(SpL), Leq, LAE, Lmax & Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. built-in RS232C interface for computer communication. 70dB dynamic range (digital display), 27~130db (A) measuring range. Wide range of time settings for Leq, LAE, Lmax & Lx;10s,1,5,10, 15, 30min,1, 8, 24h & manual time setting (up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display, 0.1db resolution, updated every second, plus 60dB analog display display 1dB resolution showing the instantaneous value. Memory battery back-up. AC & DC signal o/p for level expanding system by optional filters, memory card & others. Rion NL-05 Type 2 Sound Level MeterRIO,NL-05 AUSound level meter to IEC 651/1979 & IEC 804/1985 type 2 requirements. Measures Lp, Lmax, Leq, Lae. Response types A, C, and flat. Fast and slow time weightings. Complete with calibrator. Internal memory and print-out for Leq data (printer Cp-10 optional, also prints other parameters), RS232C interface. Recorder outputs 1V ac rms & 3.5V dc. Operates from batteries or ac adaptor.Rion NL-11FP Sound Level Meter SystemRIO,NL-11Fp MYSound level meter complete with type Nx-01A octave filter, Cp-01 printer, & calibrator. Measures Leq, Le (Lax), Spl and time. Weighting filters A, C, and flat. Detector reads fast, slow, impulse, and peak (IEC 651). Measurement range 29 ~140 db rms.

B&K 2239A Type 1 Sound Level Meter NATA CertificationbK,2239A-NATA AUType 1 (class 1) integrating sound level meter with backlit LCD display, NATA certification. Simultaneous rms (A,C) & peak (C) detection with independent frequency weightings. Measuring range 30~140db. Time weightings fast, slow and impulse. parameters Leq, Maxp, MaxL, MinL, peak, SpL and Inst. Memory for 40 data records with realtime clock. Serial port for data download. Calibrator included. Operates with 4 x AA alkaline batteries.Rion NL14 Type 1 Sound Level Meter/AnalyserRIO,NL14 AU/MYPrecision integrating sound level meter meeting IEC type 1 standard. Fitted with Nx-04 single octave filter module range 31.5~16kHz in 10 bands. Supplied with NC73 calibrator. Weightings A, C, & flat. Measurement range with A weighting 25~130dbA. Measurement functions Lp (SpL), Lmax, Leq, Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold. Leq time from 10s~100h. In-built memory for up to 9,000 readings (Lp). Outputs 1V ac rms, 3.5V dc, RS232C interface. Continuous operation on batteries for 12h. AC adaptor included. Rion NL14 SLM with 1/3 & 1/1 Octave Filter NATA CertificationRIO,NL14-NATA AUPrecision integrating sound level meter to IEC type 1 (class 1) specification, with NATA certification. Supplied with 1/1 & 1/3 octave filter module Nx-05, and calibrator NC73. Frequency range 20~12,500Hz with weightings A, C, & flat. Measurement range (A) 25~130db. Measurement functions Lp (SpL), Lmax, Leq, Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold. Leq time from 10s~100h. In-built memory for up to 9,000 readings (Lp). Outputs 1V ac rms, 3.5V dc fs, RS232C interface. Alkaline batteries 12h operation or ac adaptor.Rion NL-31 Type 1 SLM with 1/1 & 1/3 Octave FilterRIO,NL31 NZComplies with standards, IEC60651: 1979 Type 1, IEC60804: 1985 Type 1, IEC/CDV: 61672-1 Class 1. Simultaneous measurement of: sound level (Lp), equivalent continuous sound presure level (Leq), sound exposure level (LE), Maximum (Lmax) & Minimum (Lmin), percentile sound pressure level (LN), 5 selectable settings. Measurement ranges are: A weighting: 28~138db, C weighting: 33~138db, flat: 38~138db, peak sound level: 141db. Time weightings are: fast, slow, impulse (impulse is selectable only for auxiliary processing functions). Ranges 100db dynamic, frequency 20~12,500Hz (including microphone). Timer function for automatic measurement over extended periods. Supplied with Nx-21SA 1/1 and 1/3 octave filter card.Rion NL-32 SLM with RTA & NATA CertificationRIO,NL-32RTA-NATA AURIO,NL-32 NZPrecision integrating sound level meter to IEC type 1 (class 1) specification, with NATA calibration. Fitted with internal Compact Flash Card reader and supplied with NC-74 field calibrator. Frequency range 20~20,000Hz with weightings A, C, and flat. Time weightings fast, slow and impulse. Measurement range (A) 28~138 db. broadband measurement functions Lp (SpL), Leq, Lmax/min, Lae, Lx, and selectable auxiliary functions with manual or auto storage [logging]. Measurement time (Leq) from 10 seconds to 200 hours. Inbuilt memory for up to 100 data sets, or to limit of fitted CF card using manual or auto storage. AC or dc outputs, RS232C interface and cable CC-93 for serial printer. Supplied with Nx-22RT card for real time 1/1 and 1/3 octave analysis and display, for measurement functions Lp, Leq, LE, Lmax and display of Ap (all-pass) Ap(A) and 1/1 or 1/3 octave values as selected, with manual data storage only to Nx-22RT card. Download of card-data to pC requires flashcard reader. Alkaline batteries (24h operation) or AC adaptor.

nOiSe & SOund analySerS

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 121

OCCU

PATI

ONAL

HEA

LTH

& SA

FETY

Page 132: 2007 Rentalsolutionsguide-Aunz Low

B&K 2238E Type 1 Integrating SLM Enhanced Software & LoggingbK,2238E-NATA AUType 1 (class 1) Integrating sound level meter with additional functions including enhanced software, frequency analysis and data logging. Standard routines include functions for workplace measurements and general sound-level checks; enhanced software (firmware) offers additional measurements and statistics for assessment of environmental noise problems; frequency analysis automates measurements in the 9 single octave bands and 29 1/3 octave bands. Supplied with field calibrator. Compatible with BK,7815 Noise Explorer Environmental software for download, data analysis and display.B&K 7815 Environmental Software - Noise ExplorerbK,7815 AUSoftware package for downloading and reporting of noise data measured with B&K meters. Compatible with sound level meters (2239, 2238) and noise dosemeters (4443). Offers data transfer, formatting of data for export, display and print in tabular or graphical form, file management and calculation of sound power or sound reduction index from intensity measurements.ARL EL-215 Environmental Noise LoggerARL,EL-215 AUEnvironmental noise logger. portable, self-contained and weatherproof. Monitors environmental noise continuously for up to 3 weeks. Calculates and stores 2048 sets of measured data. Continuous 90db dynamic range. A and C frequency weightings. Logs date, time, Leq, Lmax, L1, L5, L10, L50, L90, L95, L99, Lmin, temperature and battery (plus additional sensor). Scan interval 1 min~1 hour. RS232C interface. pC required for initial setup and results download.

ARL EL-315 Environmental Noise LoggerARL,EL-315 AU/NZ/MYEnvironmental noise logger with display for field-reading of summary results. portable, self-contained and weatherproof. Continuous 90db dynamic range, frequency weightings A and C. Monitors environmental noise continuously for up to 3 weeks, calculates and stores over 7500 sets of Ln indices. pC required to set up system and download data using software supplied. Set up also possible from front-panel.

nOiSe & SOund analySerS

TSI SidePak SP730 Personal Sampling PumpTSI,Sp730 AUPersonal sampling pump with internal digital flowmeter. Flow range to 3,000ml/min with internal low-flow bypass for precise control and measurement at low and high rates. Keypad programming with lockout option. Multimode operation for manual control and preset programs with intermittent sampling. Supplied with “Trakpro” data analysis software and USb interface. battery powered, 2,700mAH rechargable NiMH gives up to 18.5h at 1L/min. Intrinsically safe.

Severn Model Tortus II Floor Slip TesterSEV,TORTUSII AUFloor friction tester. Measures and records the dynamic coefficient of friction. Applications in assessing floor safety, evaluating cleaning methods and maintenance procedures, accident investigation, etc. Meets the draft requirements of international, Australian and New Zealand standards.

Lion Breath Alcohol AnalyserLIO,SD-400p AUportable breath alcohol analyser with attached printer. Uses disposable mouthpieces. Approved by most law-enforcement agencies.

Oh&S & envirOnmental - general

122

OCCUPATIONAL HEALTH & SAFETY

Page 133: 2007 Rentalsolutionsguide-Aunz Low

gaS analySiS & mOnitOring

Model O2 CO CO2 NO NO2 SO2 H2S CH4Efficiency

Calculations Notes Temp °CMax Type

TES,325-1 Y Y Y* YIndustrial

Domestic & lightOil & gas burners

600 Combustion efficiency

TES,300M Y Y Y* Y Y DomesticIndustrial

1,200 Combustion efficiency

TES,325M Y Y 500Flue Gas Analyser

TES,335 Y Y Y Y Y Y Industrial 1,000

TES,350 Y Y Y* Y Y Y Y DomesticIndustrial

Power generationGeneral

1,200 CombustionFlue Gas analysis

TES,350xL Y Y Y Y Y Y Y 1,000 Combustion efficiency

LAN,SERIES2-6 Y Y Y* Y Y Y Y Y Domestic, IndustrialPower generation 1,000 Combustion

Flue Gas analysis

NOV,1637-5CGA Y Y O2 by Zirconia sensorCO2 by NDIR ~600 Flue gas analysis

ISC,MDU420 Y Dual rangeNDIR methane analyser ~1,000

Flue gas and general analysisMethane

*Calculated

Model O2LEL

(combustion)C O

ppm H2S Other Notes Applications

ISC,ITx-STD

30%

50 ppm (CH4) to 100% LEL

1,000 1,000

Full confined space kitLogging & download Personal monitoring

Confined space entryISC,TMx412

100%

Full confined space kit

ISC,MG140Personal monitoring

AIM,4650 25% 1,500 500 Logging

NOV,1637-5 from 1 ppm CO2~100 % Zirconia & NDIR sensors

Wide rangeGeneral purpose

ScientificFood packaging

ISC,MDU420 CH4~100 % NDIR sensorLogging & download

General purposeLandfill methane

AER,500L portable Logging Ozone Monitor O30~0.500ppm

Mains or batteryLogging & download

Indoor air quality“Sick building” syndrome

ppM,FORM400 Formaldehyde0.05~10.00 ppm

Formaldehyde emissions from resins, furniture, textiles,

etc

LIO,SD-400p Alcohol Approved design Breath – alcohol

RAE,MR200 Detects, screens and measures VOC contaminants. Sensitive to benzene, Ammonia, Gasoline vapour and many more. Photoionisation detector Environmental & OH&S

General

bAC,LEAK10 portable leak detector for combustion gases. Detects methane to ~ 20 ppm

Visual & audible leak indication

Environmental & OH&SHeating, Ventilation & Aircon

(“HVAC”)

ION,GASCHECK3000 portable leak detector using thermal conductivity.Wide range of gases including helium. Visual & audible signal General purpose

High sensitivity

ApT,ODA6000Cp Portable Gas Monitor Carbon MonoxideNitrogen Dioxide

Car parksLoading Areas

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 123

GAS

ANAL

YSIS

Page 134: 2007 Rentalsolutionsguide-Aunz Low

>NEW Testo 335 Combustion Gas Analyser

TES,335 AUportable industrial flue gas analyser. Determines temperature (to ~1000 deg C), draught/pressure (±40hpa), oxygen (21%), carbon monoxide (10,000ppm) and nitric oxide NO (3000ppm) concentrations. Calculates carbon dioxide concentration, efficiency and flue gas loss. Threshold-protection of sensors, with 5x autodilution of CO to 50,000ppm. Separate sensor-socket with mini-probe for ambient temperature, and connection points for compatible differential-pressure devices. built-in condensate-trap with warning and auto-switch-off. Internal memory [100 folders x 10 locations x 200 datasets each] for storage of measurement-protocols and data for printout. Supplied as kit with 335mm probe, cone and shield-plate, cordless printer and power supply. Rechargeable or AC operation (alkaline batteries used by printer).

>NEW Testo 325M Combustion Gas Analyser

TES,325M AUPortable flue gas analyser for tuning, maintenance and service adjustments of oil and gas burners. Determines temperature (to ~500ºC), draught/pressure, oxygen (21%) and carbon monoxide (4000ppm) concentrations. Calculates carbon dioxide concentration and gross/net efficiency. Supplied as kit with probe, cordless printer and power supply for mains operation. Operation 230Vac (with power supply) or alkaline batteries (AA also required by printer).

gaS analySiS & mOnitOring

124

GAS ANALYSIS

Page 135: 2007 Rentalsolutionsguide-Aunz Low

gaS analySiS & mOnitOringTesto 325-1 Combustion Gas AnalyserTES,325-1 AUPortable flue gas analyser for measurements and adjustments of oil and gas burners. Determines temperature (to 600OC), draught/pressure, oxygen (21%) and carbon monoxide (2,000ppm) concentrations. Calculates CO2 concentration and gross/net efficiency. Supplied as kit with probe, cordless printer and power supply for mains operation. Operation 230V ac (with power supply) or alkaline batteries (AA, also required by printer).Testo 300M Combustion Gas AnalyserTES,300M AU/NZ/MYFlue gas analyser for combustion efficiency measurement. Temperature range -40~1200OC ±0.5 (<100) ±0.5% (>100) with gas probe operation to 1,000OC max. Draught/pressure range 80mbar, ±0.03 . Gases measured: O2 0~21%, ±0.2%; CO2 [calculated] 0~CO2 max %vol ±0.2%; CO 0~8,000ppm, ±20 (<400), 5% (<2,000) & 10%; NO 0~3,000ppm ±5 (<100), 5% (<2,000) & 10%. Calculated gross/net efficiency 0~120%, 0.1% resolution.TSI CaCalc CA-6215 Combustion AnalyserTSI,CA6215 NZPortable combustion analyser for tuning burners for max efficiency. Measures O2, CO, NO & NOx, flue gas temperature & draft pressure. Calculates efficiency, excess air, %CO2 and emission rates. Emission gas concentrations use the adjustable O2 reference. Stores up to 350 samples for 35 sites and 75 systems and stored data includes fuel parameters, time and date stamping. Has RS232 interface for uploading of stored data or unit can be supplied with optional printer for instant hard copy output.Lancom Series II Combustion Gas Analyser LAN,SERIES2-6 AULightweight portable flue gas analyser with data logging. Measures O 25%, CO 2,000/4,0000ppm, SO2 2,000ppm, NO 1,000ppm, NO2 100ppm & H2S 200ppm. Calculates CO2 efficiency, excess air and loss. Probe temperature 600OC continuous, 1,000OC intermittent. Fitted with sleep & wake facility for semi continuous monitoring. With serial port and software. Internal rechargable battery and mains power supply.AIM 650 Four-Gas Monitor with Internal LoggingAIM,4650 AUFour gas toxic/combustible confined space or personal monitor with data logging and internal recall. Measures combustibles (CH4 equivalent) 0~100% LEL, O 0~100%, CO 0~1,500ppm & H2S 0~500ppm. Alkaline batteries for 12~18h operation.Bacarach Leakator 10 Combustible Gas Leak DetectorbAC,LEAK10 AUportable leak detector for combustible gases. Flexible probe with solid-state sensor for rapid area checks and pinpointing of large or small leaks. Sensitive to combustible vapours including common solvents, and gases including natural gas. Adjustable sensitivity with detection limit approximately 20ppm [methane]. Indication by ultra-bright LEDs and audible speaker. battery powered.PPM 400 Portable Formaldehyde MeterppM,FORM400 AUPortable Formaldehyde meter for measuring airborne formaldehyde in the workplace. Electrochemical sensor, with internal pump for rapid response. Operating range 0.05~10ppm with readout on 4 digit LCD display. Kit includes field calibration standard. Operates from 9V alkaline battery.

Testo 350XL Portable Flue Gas AnalyserTES,350xL AUPortable flue gas analyser. Measures O2, CO, CO2 (measured by NDIR), NO, NO2, and SO2 concentrations plus draught, temperature, excess air, and gross/net efficiency values. Ranges: O2 0~25% vol, CO2 0~50% vol, CO with H2compensation 0~10,000 ppm with measuring-range extension and selectable dilution factor, NO 0~3,000 ppm, NO2 0~500 ppm, SO2 0~5,000 ppm, draught 50 hpa, temperature -40~+1,000OC. Includes switch-off and rinse function for CO cell and fresh air rinse for longer term measurements. Internal memory for 250,000 readings, with RS232C interface and software provided. Operation from mains or rechargeable battery.

Testo 350 Combustion Gas AnalyserTES,350 AUMeasures O2, CO, CO2, NO, NO2, and SO2 concentrations. Calculates CO2 concentration and indicates draught, temperature, excess air, and gross/net efficiency values. Ranges: O2 0~21% vol, CO with H2 compensation 0~10,000ppm, NO 0~3,000ppm, NO2 0~500ppm, SO2 0~5,000ppm, draught ( 50hpa), temperature -40~1,200OC. Complete with printer and RS232C interface. Battery and ac mains operation.Novatech O2 & CO2 Combustion Gas AnalyserNOV,1637-5CGA AUOxygen and carbon dioxide analyser for flue gas/combustion gas applications. Special version of model 1637-5, with steel transfer tubing, closed IR cell (sapphire windows) and ruggedised internal flow path. Fitted with filtration system for moisture protection. 240V, 50Hz.Portable Logging Ozone MonitorAER,500L AUportable ozone monitor fitted with low concentration-range detection head. Operating range 0.000 to 0.500 ppm ozone with display in ppm or mg/m3. Gas sensitive semiconductor [GSS] sensor for accurate low-level measurements, T90 response approximately 100 sec. Operation from mains power supply or battery pack (4 hours operation). Internal data logging for 8000 points with software and cable for download to PC, or data logging direct to pC. Application for indoor air quality measurements.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 125

GAS

ANAL

YSIS

Page 136: 2007 Rentalsolutionsguide-Aunz Low

ISC MG140 4-gas Personal Monitor for CH44 , O2, CO & H2SISC,MG140 AUFour gas personal monitor for combustible gases (% LEL), oxygen (% O2), carbon monoxide (ppm CO) and hydrogen sulphide (ppm H2S). International approvals UL & CSA - class 1, groups A, b, C & D. Audible [90db] and visual alarms. Supplied with case and belt-loop, calibration cup and battery charger. Run time 8-10h on full charge.

ISC Gas Monitor for CH4, O2, CO & H2SISC,TMx412 AU/NZFour gas monitor complete with confined space entry kit. Detects 4 gases flammable (CH4), oxygen (O2), carbon monoxide (CO) and hydrogen sulphide (H2S). Measures % LEL flammable, % O2, ppm CO & H2S. Intrinsically safe EEx ia T4 rated (Australian Approved). Confined space entry kit includes sampling pump, tubing, filters and carry case. Designed to test confined spaces from a safe area prior to entry. Supplied in carry case complete with training video and battery charger. Other sensor options available at extra cost. battery pack run time 8h (18h with lithium batteries).

ISC ITX 4-Gas Monitor Confined Space & LoggingISC,ITx-STD AUMulti-gas monitor with confined-space kit and logging option. Configured for 4 gases: combustible 50ppm~100%LEL, oxygen 0~30%, CO 0~999ppm & H2S 0~999ppm. Intrinsically safe: Ex ia d I/IIC T4[Australia]. Confined space kit includes motorised pump, tubing, calibration cup and regulator. Logging option by time or event, up to 300h survey data at 1min intervals, with datalink/software for download. Includes training video, Li-ion battery pack with charger, and backup alkaline-battery pack.

gaS analySiS & mOnitOring

126

GAS ANALYSIS

Page 137: 2007 Rentalsolutionsguide-Aunz Low

GasCheck 3000 Portable General-purpose Leak DetectorION,GASCHECK3000 AUportable leak detector. Micro thermal-conductivity sensor for high-sensitivity detection of gases with a thermal conductivity different to that of air, including helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in five groups. Direct reading of leak rate in ml/s with audio and visible signals. Detection limit for helium 2E-5ml/s. battery powered.RAE Systems Minirae 2000 Portable PIDRAE,MR2000 AUPortable handheld VOC (Volatile Organic Compound) monitor with data logging. 3-D pID sensor (photo-Ionisation Detector) fitted with 10.6eV lamp. Ranges 0~999ppm (resolution 0.1) or 100~10,000ppm (resolution 1) VOC expressed as isobutylene. built-in correction factors for 102 compounds from a total standard library of 250. Integrated pump for local or remote (30m) sampling, with stall protection against liquid ingress. Downloadable data logging for 1,500 points with time, data and header. Intrinsically safe. Up to 10h operation with rechargeable (NiMH) or alkaline batteries.

Novatech O2 and CO2 Analyser/TransmitterNOV,1637-5 AUOxygen and carbon dioxide analyser for packaging atmosphere, general industrial and research use. Oxygen sensor reading 1ppm to 100% with 1% accuracy. NDIR carbon dioxide analysis 0~100% ±3% of full scale. 2 x 4~20mA outputs, 1 common & 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow rate with internal pump 100~500cc/min. AC operation.ISC MDU420 Logging Methane MonitorISC,MDU420 AUDual-range methane monitor with non-dispersive infrared sensor. Low range 0~100% LEL, and auto-range 0~100% methane by volume. Internal pump for ambient air or stream sampling. Datalogging included, with software and cable for download. Supplied with 450mm stainless steel probe for flue gas analysis. Rechargeable, with alkaline-battery pack as backup.

>NEW Odalog NO2 & CO Area Monitor for vehicle-parks & IAQ

ApT,ODA6000Cp AUportable multi-gas monitor for area air-quality measurement, logging or personal monitoring in car-parks, loading areas and related zones. Configured for carbon monoxide (from petrol vehicles) and nitrogen dioxide (from diesel vehicles). Ranges CO 0~500ppm (to 1ppm) and NO2 0~50ppm (to 0.1ppm). Dust and water sealed to Ip66, and rated intrinsically safe for general or mines use. Logging memory 500K readings. Integral infrared communications interface, with software and IrDA USb adaptor for configuration and download. Rechargeable, approximately 7 days operation on full charge.

gaS analySiS & mOnitOring

>>did yOu knOW….

yOu can Obtain quOteS Online, quickly and eaSily, With Our perSOnaliSed quOting SyStem?

viSit Our WebSiteS, brOWSe the catalOgue and Select the prOductS yOu are intereSted in – it cOuldn’t be eaSier.

www.techrentals.com.auwww.techrentals.co.nzwww.techrentals.com.my

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 127

GAS

ANAL

YSIS

Page 138: 2007 Rentalsolutionsguide-Aunz Low

>NEW Anton Paar DMA 35N Portable Density Meter

pAA,DMA35N AUPortable density, specific gravity & concentration meter. Measuring range 0.000~1.999 g/cc and 0.0~40.0ºC. built-in pipette style pump for sample aspiration, with port for optional syringe-filling. Display of specific gravity, ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage of up to 1024 results, with recall, and infrared port for RS232 download to serial printer or PC. Wetted parts glass and PTFE. Battery powered.

>NEW TPS WP-80 pH and Temperature Meter

TpS,Wp-80 AUportable hand-held meter for pH, mV and temperature. Supplied with combination pH electrode and separate temperature sensor on 1m cables. Operating ranges 0.00~14.00pH and -10.0~120.0ºC [automatic sensor recognition with auto pH correction 0~100ºC]. Case water resistant to Ip67, connectors to Ip65. Menu driven, with alphanumeric display. Auto storage of time and date of last calibration for GLp. Memory for 2400 readings of data, time and date, for Notepad results collection, or for AutoLog with logging intervals between 1 sec and 90 hr. Fitted with RS232C interface and supplied with download-software, charger and solutions. Rechargeable NiMH battery gives up to 50 hr operation.

TPS LC80A Portable pH MeterTpS,LC80A AUbattery operated with LCD display. Automatic temperature compensation, and analogue recorder output. Complete with combination electrode/ temperature probe with a max temperature of 60OC. Display has ranges: 0~14ph, 0~199mV, & -10~199OC.TPS Redox ElectrodeTpS,REDOx AUSilver/chloride Redox electrode for use with TpS LC80A ph meter. Supplied with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx. 231mV.

TPS WP-88 Turbidity & Temperature Meter with 8m CableTpS,Wp88 AUportable hand-held turbidity and temperature meter for field or laboratory use. Sensor probe diameter 45mm, with 8m cable. Turbidity ranging 0.1~ 200/2000NTU ±1NTU with autoselection. Temperature compensation and sensor range 0~ 60ºC ±0.1ºC. Case water resistant to Ip67, connectors to IP65, with detachable cable and sensor. Menu driven, with alphanumeric display. Auto storage of time, date and results of last calibration for GLp. RS232C interface, and memory for 150 readings of data, time and date, for Notepad results collection, or for AutoLog results collection with logging intervals between 1min and 24h. Rechargeable NiMH battery gives up to 50h operation. Supplied with download-software, charger and calibration solutions.

TPS WP-82 Dissolved Oxygen MeterTpS,Wp82 AUportable hand-held dissolved oxygen and temperature meter. Operating ranges 0~20ppm, 0~240% saturation, 0~45% gaseous and ppm with salinity correction. temperature range -10~120OC. Case water resistant to IP67, connectors to IP65, with 3m detachable cable and ED1 electrode. Menu driven, with alphanumeric display. Auto storage of time and date of last calibration for GLP. RS232C interface, and memory for 150 readings of data, time and date, for Notepad results collection, or for AutoLog results collection with logging intervals between 1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied with download-software, charger and solutions.

electrOchemiStry, Water quality

128

GENERAL ENVIRONMENTAL

Page 139: 2007 Rentalsolutionsguide-Aunz Low

TPS WP-84 Conductivity Salinity Temperature MeterTpS,Wp-84 AUportable hand-held meter for conductivity, TDS (Total Dissolved Solids) and temperature. Automatic range selection with 5 ranges. Case water resistant to Ip67, connectors to Ip65. Menu driven, with alphanumeric display for full-text prompting. Storage of time and date of last calibration for GLP. Memory for 150 readings of data, time and date, for Notepad results collection, or for AutoLog results collection with logging intervals between 1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied with sensor (k=1), charger and solutions.

YSI 55D Dissolved Oxygen MeterYSI,55D NZMeasures dissolved oxygen in mg/L or percent saturation. Range is 0~20mg/L, resolution is 0.01mg/L, accuracy is 0.3mg/L. provides simultaneous readings of O2 & OC. Dissolved O2 readings are automatically compensated for temperature. Offering push-button calibration with a built-in calibration chamber, direct salinity, and altitude compensation. Supplied with 3m cable to probe.YSI 550A Dissolved Oxygen Meter with 12ft CableYSI,550A NZHandheld microprocessor based dissolved oxygen meter for use in fresh water, sea water or polluted water. Range 0~50mg/l resolution is 0.01 or 0.1. Air saturation range is 0~500% resolution is 0.1 or 1 air saturation. Temperature range is -5°C~45°C resolution is 0.1. Features: Self-diagnostics on power up. Compensation for altitude, salinity & temperature, waterproof to Ip-67, push-button calibration, built-in calibration cha mber. Over 2,000h (alkaline) battery life at 25°C. Supplied with 4m probe lead.YSI 63 pH Salinity and Conductivity MeterYSI,63-10 NZMeasures temperature, pH, conductivity, and salinity. Ranges are: 0~14pH, resolution 0.01, conductivity is 0~200mS/cm over 4 ranges, salinity is 0~80 ppt, resolution 0.1, temperature is -5~75OC, resolution 0.1. Stores 50 readings with ID, user-selected scale or autoranging for conductivity. Supplied with a 15m cable to probe.Horiba U-20 Multi-function Water Quality MeterHOR,U-20xD1 AUMulti-parameter water quality monitor with 30m cable. Waterproof Meter unit rated to IP67 with LCD display, analog output and RS232C interface for data download using software supplied. Detachable probe, 47mmØ with stainless steel cover suitable for use in 50mm wells, with sensors for pH/ORp, dissolved oxygen, conductivity/salinity/TDS/seawater specific gravity, temperature, turbidity and depth. Data logging up to 1m @ 15min intervals. Alkaline battery operation.

Hydrolab Quanta Multiprobe Water Quality MeterHYD,QT-Mp-A AUMulti-parameter water quality analyser with 15m cable. Meter unit rated to NEMA6 (waterproof), with simultaneous parameter display, realtime manual storage of 100 frames of data and SDI interface. Transmitter probe with sample circulator, fitted with sensors for temperature, specific conductance/salinity, dissolved oxygen, pH, ORp and turbidity. Operates on 3 x C size batteries.

TPS Water Quality MeterTpS,90FL-T AUField meter and logger for water quality measurements. Configured with independent probes for pH, conductivity/salinity[TDS]/temperature, dissolved oxygen[DO] and turbidity. Cables 5m with probe holder and safety harness. LCD display readout with simultaneous display of all measurements. Manual, “notepad” storage or automated data logging for up to 1,808 sets of readings by time and date. RS232C interface, with WinTPS software included. Supplied with rechargeable battery, and clip-lead for operation from a 12V source such as a car-battery.

Hanna Portable Turbidity Meter with Case & KitHAN,HI93703C AUMicroprocessor-based, portable turbidity meter operating in the range 0~ 50FTU x 0.01FTU or 50~1,000FTU x 1FTU(NTU). Long-life IR LED source peaking at 890 nm for reduced colour-interference. Compliant with ISO7027 requirements. Unique GLp feature allows automatic storage and recall of last calibration value with time and date. Supplied in carry-case with measuring cuvettes, and maintenance kit. battery operation.

electrOchemiStry, Water quality

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 129

GENE

RAL

ENVI

RONM

ENTA

L

Page 140: 2007 Rentalsolutionsguide-Aunz Low

Analite NEP160-1 Turbidity MeterANA,NEp160 NZPortable turbidity meter suitable for potable or waste water measurements depending on the probe type. Supplied with either NEp280 100~20,000NTU waste water retro-scatter probe on a 5m cable or NEp260 0~3,000NTU potable water probe with 25m cable. Display resolution for the NEP280 probe is 10NTU, NEp260 probe is 1NTU. Repeatability is ±2% +1 digit on all ranges. Data logging up to 100 time & date stamped readings with sample intervals from 1s~90min. Analogue output with a range of 0~2V fs on any range. RS232C interface which can output readings on request or at preset intervals from 1~99s or min. DKK TOA Model RC-24P Portable Residual Chlorine MeterDKK,RC-24p-Dp AUportable, direct-reading residual chlorine meter for water analysis. Range 0~2mg/L [ppm]. Reagent-free measurement with electrode, 3m cable, float and sample container for in-situ or grab-sampling. Compatible with direct chlorination, hypochlorite or dichloroisocyanurate dosing. Calibration data stored in electrode with correlation with DPD methods. Waterproof to IP67. ISO validation functions, storage of 300 measurements and RS232 printer output. Battery operated.

Aquafluor Handheld Fluorimeter for Rhodamine WT & FluoresceinTUR,AQF-RF AUDual-channel handheld field fluorimeter. Configured for water-tracing by detection of rhodamine WT and fluorescein dyes, detection limit ~0.4ppb. RWT channel excitation 540nm, emission >570nm; Fluorescein channel excitation 475nm, emission 515nm. Internal data logging for 1000 data points, with download. Battery operated.

Spectronic Helios Epsilon Spectrophotometer VisibleSUV,EpSILON1 AUSingle beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth, operating in the range -0.1~2.5A. Wide view-angle LCD display and sealed membrane keypad with push button auto-zero. Sealed optics, with wavelength slew >4500nm/min. Operational modes absorbance, transmission, concentration and factor. Supplied with standard cellholder for 10mm square cells. RS232C port for computer and parallel interface for printer.

Van Essen Depth/Temperature Groundwater Logger 30MVAN,TD30 AUGroundwater depth and temperature logger for operation to 30m. Independent probe 22mmØ x 125mm long with internal memory for 2 x 24,000 measurements, battery-life 8~10y. Reader for set-up and download of data using standard computer. Supplied with “baro Diver” - ambient/surface logger for atmospheric pressure correction.

Isco 6700 Series Water Sampler with Bubbler Flow ModuleISK,6700-730 AUAdvanced water sampler for fully programmed collection. Samples can be collected in 1, 2, 8, or 24 glass or plastic sample containers based on time, flow, and/or parameter set points. Fitted with NEMA 4x,6 (Ip67) sealed controller featuring an exclusive, built-in pump, flash memory for easy programming changes, and a plug-in module port for connection of a flow meter module or parameter measurement module to enhance monitoring capabilities. Provided with bubbler flow module. Sample bottles available. Run from rechargeable 12V sealed batteries.

electrOchemiStry, Water quality

130

GENERAL ENVIRONMENTAL

Page 141: 2007 Rentalsolutionsguide-Aunz Low

SpectrOScOpyShimadzu UV-Mini 1240 Spectrophotometer UV-VisibleSHI,UV-1240 AUSingle beam scanning UV-visible spectrophotometer, 190~1,100nm with 5nm bandwidth. Large LCD display for on-screen viewing of results, calibration curves and spectra. Standard applications include photometric measurement, spectrum scanning and quantitation. IC data card system for storage of raw data, methods and results, with optional program packs for additional applications. Interface ports for printer or computer. 220~240V, 50/60Hz.

Spectronic Helios Epsilon Spectrophotometer VisibleSUV,EpSILON1 AUSingle beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth, operating in the range -0.1~2.5A. Wide view-angle LCD display and sealed membrane keypad with push button auto-zero. Sealed optics, with wavelength slew >4500nm/min. Operational modes absorbance, transmission, concentration and factor. Supplied with standard cellholder for 10mm square cells. RS232C port for computer and parallel interface for printer.

X-Rite SP60 Portable Sphere Colour SpectrophotometerxRI,Sp60 AUPortable spectrophotometer for surface colour measurements. Diffuse 8O [d/8] optical geometry with fixed 8mm aperture. Tungsten source for illuminant types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard observers 2 & 10O. blue-enhanced photodiode detectors with spectral range 400~700nm. Measures opacity and colour by chromatic, apparent or tristimulus calculation, with simultaneous included and excluded specular component, and spectrum at 10nm intervals. Storage of up to 2,000 samples with results download to serial printer or computer. Operation from internal rechargeable battery or ac adaptor.

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 131

GENE

RAL

ENVI

RONM

ENTA

L

>NEW Anton Paar DMA 35N Portable Density Meter

pAA,DMA35N AUPortable density, specific gravity & concentration meter. Measuring range 0.000~1.999g/cc and 0.0~40.0ºC. built-in pipette style pump for sample aspiration, with port for optional syringe-filling. Display of specific gravity, ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage of up to 1024 results, with recall, and infrared port for RS232 download to serial printer or PC. Wetted parts glass and PTFE. Battery powered.

Hydramotion Viscolite 700 Portable ViscometerHYL,V700S-21 AUAdvanced portable viscometer with stainless-steel probe. Operating range 0.1~10,000mpaps (cps) with integral temperature correction -40~150ºC. probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm (viscosity/temperature). Acetal polymer probe base for handheld or clamped operation, with coiled-cable connection to meter unit with 5 digit display. Battery powered.

materialS teSting

Page 142: 2007 Rentalsolutionsguide-Aunz Low

>>did yOu knOW….

yOu can regiSter Online tO receive advance nOtice Of neW prOductS, prOmOtiOnS and technical neWS?

viSit Our WebSite and regiSter tOday.

www.techrentals.com.auwww.techrentals.co.nzwww.techrentals.com.my

Page 143: 2007 Rentalsolutionsguide-Aunz Low

CALIBRATION

Page 144: 2007 Rentalsolutionsguide-Aunz Low

134

CALIBRATION

calibratiOn ServiceS. Online. Ontime. everytime.

Why deal With uS:• ExpEriEncEd,

qualifiEdstaff• nataaccrEditation• isoqualitycontrol• 22convEniEnt

locations• onlinEsErvicEs

(australiaonly)• onEstopshop

facilityforallyourcalibrationnEEds

induStrieS SuppOrted:• aviation• dEfEncE• ElEctrical• ElEctronic• biomEdical• mEchaical• tElEcommunications

TR Corporation services also include calibration. These services are delivered through TECHRENTALS and VMS.Our laboratories are staffed by experienced technical engineers and technical officers to provide internationally recognised calibration services. Utilising state-of-the-art specialised instrumentation, each is NATA accredited, with ISO quality systems in place for traceability and control.

Our ServiceS:• calibration• rEpairs• salEs• totalassEt

managEmEnt• mobilEcalibration

facilitiEs

talktoyourtEchrEntalsconsultant

abouthowwEcanhElpsolvE

yourcalibrationproblEms

Page 145: 2007 Rentalsolutionsguide-Aunz Low

aAC See ElectricalAccelerometer 88-89Acoustic Spectrum Analysis 119Adhesion Tester 91Air Compressor Output 112 Flow 112-117 Quality 113-115, 117Air Conditioning Coolant Flow 110, 112 Electronic Manifold 118 Measurement 113-114 Valve Balancing 118Air Quality Monitoring 113-115, 117, 126 particles 113-114, 117 Temperature & Humidity 113-114, 117Air Velocity Meter 112, 115Alcohol breath Analyser 122Alignment 88-89Ammeter 60, 62Amplifier Instrumentation 73Anemometer 113-115, 116Angle Measurement 63Antenna & Cable Test 18-19Antennas 19-20, 37Appliance Tester 46-47Area Heat Stress 113-114, 117Audio Analyser 26Autoclave Logger 70, 73Automotive Testing 90bBalances 85, 87Balancing Machinery 118balancing Machinery Analyser 88balometer 113-114, 115Barometric 102Barometric Recorder 102Bath Constant Temperature 94-95, 97 Ultrasonic 100Bit Error Rate (BERT) 28Blast Logger 90body Vibration Measurement 88-89Bore Hole Depth 130Bore Hole Water Quality 129Borescope 79, 81brake Tester 90Bridge LCR 9cCable Fault Locator 36-37 LAN Test 32 Locator 32, 36-37 Tester 32, 36-37 Tracer 36-37Cable Locator 36Cable Tester 36Cable TV 27Calibrator Current 94-97 Current Loop 94-96, 98 Dry block Temperature 94-95, 97-98 Electrical 9 Hydraulic 94-95, 99-100 Industrial 94-95 Loop 94-95 pneumatic Instruments 94-95, 98 pressure 94-95, 98-100 process 94-96 Resistance 94-96 Temperature 94-95, 97-98 Voltage 94-96, 98-99Caliper 78Camera Digital 106 Endoscope 79, 81 High Speed 82 pipe Inspection 79-81 Surveillance 106 Thermal Imaging 104-105 Video 82Carbon Dioxide (CO2)

113-114, 117, 124-127Carbon Monoxide (CO)

113-114, 117, 124-126Cat 5, 5E, 6 32CCTV Surveillance 106

Charge Amplifier 88-89Chart Recorder 76, 82-83Circuit breaker Analyser 58Circuit Tracer 36Clean Room Monitor 117Cleaver - Fibre Optic 35Coating Thickness 90-92Coil & Winding Test 41, 46Combustion Gas Analysis 123-126Communications Test Set 21Compressed Air Flow 112Compressor Output Flow 105 Quality 105Concrete Testing Adhesion 91Cover Meter 92 Moisture Meter 92-93 Reo Depth 92-93 Test Hammer 92-93 Ultrasonic Tester 91-92Conductivity & Salinity 129Confined Space Entry 123, 126Counting Scales 87Crane Scales 86CurrentClamp 46, 53-54, 57, 60-65, 75 DC Source 7 Injection 65 Input Logger 70, 73 Loop 94-95, 96-98 Meter 48-49, 56, 60, 62-63, 110-111 Primary Injection 65 probe 4, 61-62 Secondary Injection 65 Sensor 75 Shunt 60, 63 Transducer 53, 60, 63, 75 Transformer (CT) 48-49, 51, 56, 60dData Communications Cable Test 32 Etherscope 29 Fibre Optics 33 LAN Analyser 29 Protocol analyser 31 protocol Analyser 28, 30-31 WAN analyser 31 WAN Analyser 29, 31Data Logger 70-73, 83DC High Voltage 4, 59DC Power Supplies 7Decade Resistance Box 9Demand Analyser 48-49, 51, 56Density Meter 86, 128, 131Depth Logger 130Dewpoint 105, 113-114, 117Digital Camera 106Digital Storage Oscilloscope 2Dimension Measurement 78Dissolved Oxygen 128-129Distance Measurement 78Distortion Analyser/Generator 26Dose Meter (Noise) 120-121Dust Measurement 113-114, 117eE1/E3 Tester 28-31Earth Leakage 41- 45, 48-49, 59-60, 62, 65Earth Tester 46Electric Motor Test 46Electrical 40Electrical Cable Test 41-45, 59 High Voltage 59, 65 Surge Generator 36 TDR 36 VLF 59Electrical Installation & Test Appliance Tester 46-47 Earth Leakage (RCD) 41-46, 48-49, 60, 62, 65 High Voltage Test (Hi-pot) 46, 59 Insulation Test 40-45, 59 Phase Rotation 63 Resistance Test 41-45, 46 Soil/Ground Resistance 41, 45-46Electrical Power Generation

& Transmission Current Injection 65 High Voltage Test (Hi-pot) 59

power Quality 48-54, 56 Protection Relay Test 57 VLF Test 59Electrical Power Quality Demand Analyser 51-54, 56 Harmonics 48-49, 51, 56 power Factor 48-49, 51, 53-54, 63 power Quality Analyser 48-50, 53-56 Voltage Current Recorder 76 Electrical Power Sources Current Injectors 65 Generator 68 Line Conditioners 66 UpS 66-67Electrical Testers 63Electrical Transducers 60, 62Electrochemistry 128Electrometer 5Electrostatic Charge Measurement 6EMC/EMI Test Equipment 21Endoscopes 79-81Environmental Chambers/Oven 100-101Environmental Noise 120, 122Ethernet Analyser 29-30fFibre Optic Microscope 35Fibre Optics 33-34 Fusion Splicer 35 LAN Cable Test 32 OTDR 34 PMD 35 power Meter/Light Source 33-35Field Strength Meter Gauss 40 RF 19-20Field Strength Meters & Antennas 19-20Filters 26Flash Card 75Flaw Detector 90Floor Slip Tester 122Flow Meters 110-112 Compressed Air 110, 112 Doppler 110-112 Gas 110, 112 Liquid 110-112 Non-Intrusive 110-112 Open Channel 110-112 Transit Time 110, 112 Ultrasonic 110-112Flue Gas Analysis 123-125Flue Inspection 79-80Fluorimeter 130Force Gauge 84Formaldehyde Meter 123, 125Frequency Counter 12Frequency Response Analysers 10Frequency Transducer 60, 63Function Generator 8Fusion Splicer 35gGamma Radiation 19-20Gas Alcohol 122 Carbon Dioxide (CO2) 117, 124-127 Carbon Monoxide (CO) 117, 123-127 Flammable (LEL) 125-126 Formaldehyde 123, 125 Hydrogen Sulphide (H2S) 125-126 Methane (CH4) 123, 125-127 Nitric Oxide (NO) 117, 123-126 Nitrogen Dioxide (NO2) 123-127 Oxygen (O2) 123, 126-127 Ozone (O3) 125 Refrigerant 118 Sulphur Dioxide (SO2) 123 VOC 123, 127Gas Analysis &

Monitoring 123, 125-127Gauss/Tesla Meter 40Generator (AC) 68Glossmeter 90GpIb Interface 4Ground Vibration 90Groundwater 130hHardness Tester 93Harmonics (power) 48-50, 56Heat Stress 113-114, 117

High Voltage Insulation Dielectrics Test Set 42

Hi-pot Tester 46, 59Holiday Detector 91Hot Wire Anemometer 113-114, 116Humidity Chamber 101 Concrete 92 High Temp probe 77, 83-84 Indoor Air 113-114, 117 Logging 70, 72-73 Natural Gas 105 Recorders 102 Thermohygrograph 102 Transducer 77, 83-84 Weather 118HVAC & IAQ 112-117Hybrid Recorders 76Hydraulic pressure 91, 94-95, 99-100iIlluminance Meter 119Inclinometer 84Indoor Air Quality 113-114, 117Infrared Camera 104-105Infrared Thermometer 102-103Injection Test Set 65Instrumentation Amplifier 73, 76Insulation Tester 41-45, 59, 65Intrinsically Safe Current Loop Calibrator 94-95, 98 Digital Multimeter 6 Gas Monitor 126 Moisture Analyser 105 Noise Dose Meter 120-121 photo-Ionisation Detector (pID) 123, 127Inverter 68Ionisation Tester 59ISDN 28, 31lLaboratory Oven 101LAN Analyser 29-31 Cable Certification 32 Cable Tester 32Laser Distance & Speed 78 Level 78LCR Meter 9Leak Detector Gas Pipe 37, 118, 125, 127 Microwave Oven 19-20 Refrigerant 118 Water 37Light Measurement 119Light Meter 119Linear position Transducer 84Load Cell 85-86Logger 70 Accessories 71 Autoclave 70, 73 Data 70-73, 83 Environmental Noise 120, 122 Explosion 90 Flow 110-111 Ground Vibration 90 Humidity 70, 72-73 Oven 70 Pressure 102 Shipping & Transport 89 Temperature 70-73Logic Analyser 10Logic Programmer 10Low Frequency Frequency Response Analysers 10 Signal Generator 26Luminance Meter 119Lux Meter 119mMachinery Balancing 88 Vibration 88-89Magnetic Field Meter 40Manometer 114-115Materials Testing 86, 128, 131Memory Recorder 73-75Metal Detector 106-107Methane Monitor 123, 127Micro-Ohm Meter 41-43

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my 135

GENE

RAL

INDE

X

Page 146: 2007 Rentalsolutionsguide-Aunz Low

Microscope 82Microwave Leakage Detector 19-20Microwave Oven Survey Meter 19-20Modified Atmosphere packaging Test 123, 127Modulation Meter 20Moisture Concrete 92-93 Timber 92Moisture Balance 87Multimeter 5-6nNatural Gas 105Network Analyser Antenna & Cable Test 18-19 LAN/WAN 29 power 48-49 RF 13, 18, 26 Telecommunications 28Noise & Sound 120Noise Dose Meter 120-121Noise Logger 120, 122Non-Destructive Testing

(NDT) 88, 90-92Non-Storage Oscilloscope 3OOccupational Health & Safety 119, 122 Air Quality 113-114, 117 Appliance Testing 46-47 Confined Space Entry 123, 125-126 Floor Slip Tester 122 Formaldehyde 123, 125 Heat Stress 113-114, 117 Lighting 119 Noise & Sound 120 Ozone 123, 125 Radiation 19-20 Toxic Gas 123, 125, 127 UV Exposure 119 Vibration 88Oil Insulation Tester 41, 46Optical Networking DWDM 35Optical Spectrum Analysis 35Oscilloscopes Digital Storage 2-3 Non Storage 3 portable 2-3 probes 4OTDR 34Oven 101Oven Logger 70Oxygen & CO2 Analyser 123, 125, 127Oxygen (O2) 123, 125, 127Ozone (O3) 123Ozone Monitor 123pparticle Counter 113-114, 117pAT 46, 47PCM Test Equipment 28pDH Analyser 28People Counter 107Petrol Generator 68pH Measurement 128phase Angle 63Phase Rotation Meter 63Phase Sequence Meter 63photo-Ionisation Detector (pID) 123, 127Pinhole Detector 91Pipe Locators 36Pipeline Inspection 79Pitot Tube 115Plotter Printer 76Polarisation Mode Dispersion (PMD) 35portable Appliance Tester 46, 47position Transducer 84POTS 28Power See Electricalpower Analyser 48-49, 51-56, 63Power Demand

Analyser 48-49, 51-54, 56power Disturbance 48-49, 51, 56Power Line Conditioner 66power Supplies - DC 7Pressure Calibrator 94-95, 97-100 Circular Chart Recorder 82-83 Indicator/Gauge 77, 82-83

Transducer 77, 83Probe Current 4, 48-51, 57, 61-62 Digital 75 Frame Relay 31 High Voltage 4 Line Logic 75 Static Detector 6process Calibrator 96-98Programmer EPROM, EEPROM 10Protection Relay Test 57protocol Analyser 28, 30-31Pulse Crest Meter 91Pulse Generator 9Pulse Porosity Detector 91pump 94-95, 98-100rRadar Speed Gun 78Radiation Monitor 19-20Radiometer 119Random Noise Generator 26RCD Test 41, 45Recorders 70 Barometric 102 Chart 76, 82-83 Hybrid 76 Memory 73-75 Pressure 82, 83 Tape 76 Temperature Humidity 72Rectifier 7Refrigerant Leak Detection 118Relative Humidity 102 Also See HumidityRelay Test 57, 65Resistance Calibration 94-95 Decade 9 Ground/Soil 45-46 Micro-Ohm 41-43 Static 41, 46 Tester 41-46Retail Traffic Flow Counter 107RF & Microwave Accessories 26 Amplifier 13 Antenna/SWR 18-19 Antennas 18-20 Attenuator 25-26 Communications Test Set 21 EMC/EMI Test 14, 17, 20-21 Field Strength Meters 19-20 Frequency Counter 12 Function Generator 8 Modulation Meter 20 Network Analyser 13, 18-19 power Meter 22-23 power Sensors 24 Radiation Monitor 19-20 Sensor 22, 24 Signal Generator 13, 20 Spectrum Analyser 10, 14, 17 Sweep Generator 13 Voltmeter 22Rogowski Coil 48-49, 53Rotating Balancing 89Rotating Laser Level 78Roughness 91Router Test System 31RTD Calibrator 94-95SSalinity & Conductivity 129Scales 85-87Scopemeter 2-3Security Bug Detector 106 Metal Detector 106Surveillance 106Shaft Alignment 88-89Shaker Table 88, 90Signal Generator Low Frequency 26 RF 13Signalling Analyser 28Smoke Generating Machine 114Sniffer 30Soil Resistivity 41, 46Sonde 37

Sound 120 Dose Meter 120-121 Logger 120-122 Measurement 120 Signal Analysis 119Sound Level Meter 88-89, 120-122 Vibration 88-89Spectrophotometer 130-131Spectroscopy 131Spectrum Analyser Acoustic 119 Optical 35 RF 10, 14-15, 17Speed Measurement 78Splicer - Fibre Optic 35SS7 28Startup Current 48-49, 51-54Static Detector Probe 6Static Discharge Generator 21Step Transformer 21STM1 ... STM65 28, 31Strip Chart Recorder 76Stroboscopes 78-79Surface Roughness 91Surge Generator 36Surge Transient Generator EMC/EMI Test 21Survey Equipment 78Sweep Generator 13tTachometers 78-79Tape Recorders 76TDR 36-37Telecommunications BERT 28 CDMA 23 Communications Analyser 28 Fibre Optics 33-34 GSM 28 ISDN 28 PDH 28 POTS 28 SDH 28 Signalling Analyser 28 System Tools 28 WAN analyser 31 W-CDMA 23Temperature IR Thermometer 102-103 Logging 72-73, 130 Recorders 102 Thermocouple 102-103 Thermometer 102-103Tension 85Thermal Imaging Camera 104-105Thermocouple 102-103Thermohygrograph 102Time Domain Reflector TDR 36-37Token Ring Analyser 30Torque Wrench 84Total Dissolved Solids (TDS) 129Toxic Gas Monitor 123, 125, 127Transducers Current 53, 60, 63 Electrical 60, 62 Frequency 60-63 Humidity 77, 83-84 Instrument Transformer 60, 62 position 84 pressure 77, 82-83 Temperature 77, 83-84 Voltage 60, 62-63Transformer Oil Test 46Transient Burst 21Transport Inclinometers 84Turbidity 128-130TV Test Equipment 27uUltrafine particle Counter 113-114, 117Ultrasonic bath 100Uninterruptable power Supplies

- UpS 66-67UV Exposure 119vV24, V35 31Valve balancing (Air Conditioning) 118

Vane Anemometer 113-115Variacs 67VCR 82, 106Vibration Accelerometer 88-89 Analyser 88-89 Blast Logging 90 Impact Hammer 89 Logging 89-90 Table 88, 90 Transport Testing 89 Whole Body 88Video Endoscope 81 High Speed 82 Microscope 82 pipeline Inspection 79-81Video Camera Digital 106 VHS 82, 106Video Security 106Viscometer 86, 131VLF MV Cable Test 59Volatile Organic Compounds

(VOC) 123, 127Voltage Calibrator 94-95Voltage Transducer 60, 62Voltmeter 6, 22WWalk Through Metal Detector 106WAN Analysers 29-31Water Analysis 130 Conductivity 129 Depth 110-111, 129-130 Flow 110-111 Leakage Detection 37 pH 128-129 Quality 128-129 Sampling 130Water/Oil bath Temp Calibrator 94-95, 97Waveform Generator 8WbGT 113-114, 117Weather 118Wind Speed & Direction 117-118Workplace Safety

See Occupational Health & Safetyxx.21, x.24 30-31x-Ray Measurement 19-20

136

GENERAL INDEX

Page 147: 2007 Rentalsolutionsguide-Aunz Low

YOUR TRUSTED PARTNER IN TECHNOLOGY OFFERING INNOVATIVE SOLUTIONS THROUGH

OUR LEADING BRANDS:

Page 148: 2007 Rentalsolutionsguide-Aunz Low

AUSTRALIA 1800 632 652 www.techrentals.com.au

NEW ZEALAND 0800 832 473 www.techrentals.co.nz

MALAYSIA 603 5632 1135 www.techrentals.com.my

TEST & MEASUREMENT RENTAL SOLUTIONS GUIDE 2007

VOLUME 32 ISSUE 12

>ELECTRONICS & DATA >ELECTRICAL POWER >GENERAL INDUSTRIAL >ENVIRONMENTAL >CALIBRATION

YOUR TRUSTED PARTNER IN TECHNOLOGY.OFFERING INNOVATIVE SOLUTIONS THROUGH OUR LEADING BRANDS:

RE

NTA

L SO

LUTIO

NS

GU

IDE

2007 TECH

REN

TALS