5
2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC CE </> 55 MAX 2000A AC/DC MODEL 2003A

2002PA 2003A - cosinus.de · 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2002PA 2003A - cosinus.de · 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC

2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V

MODEL

2002PA CE c/>55 MAX 2000AAC

CE </> 55 MAX 2000A AC/DC

MODEL

2003A

Page 2: 2002PA 2003A - cosinus.de · 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC

AC DIGITAL CLAMP METER

CE

•Featureserear-drop-shaped jaws for

ease of use in crowded cable areas and other tight places.

eProvides a wide measuring range from O up to 2000A AC.

eTerminal cover to avoid the use of incorrect terminal.

ePEAK function to measure current peak.

eoutput terminal for long term current monitoring.

esafety design throughout conforming to the following provisions of IEC61010.

Pollution degree 2, overvoltage category l 600V

Pollution degree 2, overvoltage category I 1000V

eoata hold function to allow easy readings in dimly lit or hard-to-read locations.

es1eep function to conserve batery power.

ePermits easy continuity check with a beeper.

eProvides a dynamic range of 4,000 counts full scale.

ewite frequency range from 40Hz to 1 kHz.

eTransformer jaws fitted with guards to further improve safety.

Page 3: 2002PA 2003A - cosinus.de · 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC

AC/DC DIGIJA. CLAMP METER

CE

•FeatureseTear-drop-shaped jaws for

ease of use in crowded cable areas and other tight places.

eProvides a wide measuring range from O up to 2000A AC/DC.

eerminal cover to avoid the use of incorrect terminal.

eMAX measurement function for easy reading of maximum input over a cetain period of time.

eoutput terminal for lang term current monitoring.

esatety design throughout conforming to the tollowing provisions of IEC61010.

Pollution degree 2, overvoltage category m 600V

Pollution degree 2, overvoltage category I 1000V

eAuto-null function to allow one tauch zero adjustment.

eoata hold function to allow easy readings in dimly lit or hard-to-read locations.

es1eep function to conserve batery power.

ePermits easy continuity check with a beeper.

eProvides a dynamic range of 4,000 counts full scale.

ewide frequency range from 40Hz to 1 kHz.

erransformer jaws fitted with guards to further improve safety.

Page 4: 2002PA 2003A - cosinus.de · 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC

ln,strwment La 0111t

®

CV....-

®

Negative sign

Continuity check

@

�®@

AC DC Max Avera e mode

� �-� ml!:I E!B Cl

r, r1 r, r1 kfl

-- - - - V Lt.Lt.LI.Lt A

•IJ)aiiJmJllm)

4

Data Hold

Resistance

Voltage

Ampere

Low battery warning Peak mode auto zero

Seleection Guide

MODEL 2®02f'A 2@03A

ACA e2CJOOA e2000A

AC V e750V e?SOV

DCA e2000A

DCV e1ooov e10oov

Q .400kQ .4!000Q

Data Hold • •

Peak Hold •

MAX Hold •

DC OUTPUT • •

;

��A -�··

CD Transformer Jaws @ Jaw Trigger @ Function Selector Switch @ Data Hold Button @ AC/DC Button ® Mode Button Cf> Zero ADJ.RESET Button @ LCD Display

@ @

® Terminal Cover ® OUTPUT Terminal ® COM Terminal @ V/Q Terminal ® Safety Hand Strap @ Test Leads (7107) @ Output Plug(8201)

Application for current monitoring

Recorder

Voltage Measurement

8 8 8

Page 5: 2002PA 2003A - cosinus.de · 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT. m 600V MODEL 2002PA CE c/>55 MAX 2000AAC

Microprocessor controlled 2000A Clamp Meter Series. Newly designed to meet the International Safety Standard IEC 61010-1 CAT.m 600V.

• SpecificationsMODEL 2002PA 2003A

AG A 400A(0-400A) 400A(0-400A)

± 1.0%rdg ± 3dgt(50/60Hz) ± 1 .5%rdg±2dgt(50160Hz)

±2.0%rdg ± 3dgt(40-1 kHz) ±3.0%rdg±4dgt(40-1kHz) 2000A(0-1500A) 2000A(0-1700A)

± 1.0%rdg :!; 3dgt(50/60HZ) ± 1.5%rdg ± 2 dgt(50160Hz) ±3.0%rdg ±3dgt(40-1kHz) ±3.0%rdg±4dgt(40-1kHz) 2000A(1500-2000A) 2000A(1701 -2000A)

±3.0%rdg(50160Hz) ±3.0%rdg ±2dgt(50160Hz) AC V 40/4001750V 400/750V

± 1.0%rdg±2dgt(50/60Hz) ±1.5%rdg±2dgt(50/60Hz)

± 1.5%rdg ± 3dgt(40-1 kHz) ± 1.5%rdg ±4dgt(40-1 kHz) DC A 400/2000A

mUi'ld1dgt!l.d� DC V 40/40011 ooov 400/1000V

± 1.0%rdg± 2dgt ± 1 .0%rdg ± 2dgt Q 400 Q /4k/40k/400k Q 400/4000Q

± 1.5%rdg±2dgt ± 1 .5%rdg ± 2dgt Continuity 400Q 400Q Frequency

Output 40012000A 400/2000A Voltage DC400mV/200mV DC400mV/200mV Withstand 5550V AC for 1 minute 5550V AC for 1 minute Voltage

Conductor 4l55mm max 4l55mm max Size

Safety IEC61010·1 CAT.ID 600V IEC61010·1 CAT.ID 600V Operation CAT.11 1000V CAT. II 1000V

IEC61010-2-031, IEC61010-2-032 IEC61010-2-031. IEC61010-2-032 Power Source (R6P)(AA)1.5V X 2 ·�]ilF.eie.'il:Sl!l fü:e:ems ir;i (R6P)(AA)1.5VX 2 Approx.100 hours in

continuous use continuous use Dimensions 49(D) X 247(L) X 1 OS(W)mm 49(D)X 250(L) X 1 OS{W)mm Weight 470g approx (batteries included) Accessories 7107 (Test Leads)

8201 (Output Plug)

9094 (Carrying Gase)

(R6P)(AA)1.5V X 2

lnstruction Manual Optional 8008 (Multi-Tran) Accessories 7014 (Output Cord)

• Optional Accessories

eMulti-Tran 8008

& Safety Warnings

530g approx (batteries included)

7107 (Test Leads)

8201 (Output Plug)

9094 (Carrying Gase)

(R6 P)(AA)1.5V X 2

lnstruction Manual

8008 (Multi-Tran)

7014 (Ou_!put Cord)

eoutput Cord 7014

Please read the "Sa!ety Warnin9s" in 1110 instruction manual supplied wilh thc inslru rnent lhoroughly and completely for correct use. Failurc to lollow the safety rules can cause fire ,trouble,electrical shock,etc.Therefore,make sure to operate the instrument on a correct power supply and voltage raling rnarkf·ld on cac:h instrument.