Upload
nguyenkhuong
View
230
Download
3
Embed Size (px)
Citation preview
20+years experience
Innovative distributor engineering - metering flow with cost effective Danfoss support in design and sourcing
Alaluminum distributors
Engineering for today’s needs - superior resistance to corrosion and 66% lighter than copper
Product Catalog
Go with the advanced flow Value-added engineering expertiseDanfoss high quality distributors and flow controls, type RD
MAKING MODERN LIVING POSSIBLE
2 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog Danfoss Distributor Product Program
DKRCC.PK.FF0.A1.22 / 520H6635 3
Product Catalog Danfoss Distributor Product Program
RD 3863 Series Copper-Brass Distributor with Brass Piston................................................................... 4
Features ................................................................................................................................................................... 4
Ordering options .................................................................................................................................................. 5
RD 3863 Series Aluminum Distributor with Brass Piston. ....................................................................... 6
Features ................................................................................................................................................................... 6
Ordering options .................................................................................................................................................. 7
RD 5271 Series TXV Style Copper-Brass Distributor .................................................................................. 8
Features ................................................................................................................................................................... 8
Ordering options .................................................................................................................................................. 9
RD 5271 Series TXV Style Aluminum Distributor ................................................................................... 10
Features ................................................................................................................................................................ 10
Ordering options ............................................................................................................................................... 11
RD 5500 Series Venturi Style Copper-Brass Distributor ....................................................................... 12
Features ................................................................................................................................................................ 12
Ordering options ............................................................................................................................................... 13
RD 5500 Series Nozzle Distributor ............................................................................................................... 14
Features ................................................................................................................................................................ 14
Ordering options ............................................................................................................................................... 15
RD 6500 Series Hot Gas Bypass Style Distributor .................................................................................. 16
Features ................................................................................................................................................................. 16
Ordering options ............................................................................................................................................... 17
Piston Orifice Selection Chart ........................................................................................................................ 18
Contents Page
4 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog RD 3863 Series Copper-Brass Distributor with Brass Piston
Introduction
Features
Applications
Technical Data
The Danfoss Eliminator-Distributor with the Chatleff Omni-Direct closure is the market leading cost effective distribution solution for HVAC. The Chatleff Omni-Direct Closure allows easy interchange of piston and/or expansion valve. In use, the Danfoss
Special Orifice piston allows metered flow in the cooling cycle. In the heating cycle for heat pumps, the refrigerant by-passes the metering by flowing around the piston using the flutes.
y Chatleff Omni-Direct Closure to insure 5 – 10 years of reliability on the mechanical connection, with a replaceable Teflon seal
y Precise metering for Eliminator-Distributors, thru the unique piston with teflon seal permitting superior seating during both heat pump and cooling cycles obtaining extremely repeatable and predictable expansion and distribution from cycle to cycle
y Designed and engineered to work with any size system
y Piston may be replaced to adjust flow and pressure drop
y This distributor also designed for use with a Thermostatic Expansion Valve (TXV) or Electronic Expansion Valve (EEV)
y Qualified for use with Danfoss TR6 TXV mechanical connection with long-tail fitting
y Low unit mass reduces tube fatigue from vibration
y U.L. listed. file No. SA 3449
y The Danfoss Eliminator-Distributor is designed to retrofit from piston expansion to TXV/EEV expansion or vice-versa
RD 3863 Series RD 3863 Series Internal detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
Construction
Body: Brass
Feeder Tubes: Copper
Piston:Extruded Brass
Teflon seated
Inlet tube: Copper
Nut: Brass
Seal: Teflon
Static Pressure
Burst: 2500 psi
Rated Working Pressure: 500 psi
Max Operating Temp: 450 °F (232 °C)
Refrigerant compatibility
Standard refrigerants:
R134a, R22, R404A / R507, R407C, and R410A
A
B
C
D
E
DKRCC.PK.FF0.A1.22 / 520H6635 5
Product Catalog RD 3863 Series Copper-Brass Distributor with Brass Piston
Ordering To order, indicate option choices for the following:
y Inlet option (Brass/Copper) (see fig. A)
y Piston Orifice Size
y Feeder Tube OD (Outside Diameter)
y Number of Circuits
y Feeder Tube Length
y Feeder Tube End Form
Ordering options
Straight Expanded Bell
Brazed on Bell
Fig. E
Please make your selections in the column or space provided and fax or email your sales representative.
Contact your Danfoss sales representative for custom options.
Fig. A
Inlet option liquid line connection Indicate
Choice:ODM 3/8 ODF 3/8 Tube Length3.875 in 3.375 in Long
3.375 in 3.0 in Medium
2.5 in 2.5 in Standard
N/A 1.125 in Short
Filter/strainer option available
Fig. B
Piston Orifice Size Indicate Choice:
see chart on page 18 Orifice No.
Fig. C
Feeder Tube ength Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
Fig. D
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.144 in x 0.028 in Wall – 2 to 14 circuits
0.157 in x 0.028 inWall – 2 to 12 circuits
0.188 in x 0.028 in Wall – 2 to 12 circuits
0.250 in x 0.028 in Wall – 2 to 6 circuits
Feeder Tube End Form Indicate Choice:
0.144 in – straight no end form
0.144 in – expanded Bell – 0.310 in OD
0.144 in – brazed on Bell – 0.375 in OD
0.157 in – straight no end form
0.157 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
0.188 in – straight no end form
0.250 in – straight no end form
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Contact Information:
OD – Outside Diameter
6 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog RD 3863 Series Aluminum Distributor with Brass Piston
Introduction
Features
Applications
Technical Data
The Danfoss Eliminator-Distributor with the Chatleff Omni-Direct closure is the market leading cost effective distribution solution for HVAC. The Chatleff Omni-Direct Closure allows easy interchange of piston and/or expansion valve.In use, the Danfoss Special Orifice piston allows metered flow in the cooling cycle.In the heating cycle
for heat pumps, the refrigerant by-passes the metering by flowing around the piston using the flutes. Additionally, the aluminum alloy eliminates leaks caused by formicary corrosion. The Danfoss Aluminum RD 3863 aligns well with the industry trend to convert into all aluminum indoor coils.
y Copper inlet tube for easy field connection and service
y Chatleff Omni-Direct Closure to insure 5 – 10 years of reliability on the mechanical connection, with a replaceable Teflon seal
y Precise metering for Eliminator-Distributors, thru the unique piston with teflon seal permitting superior seating during both heat pump and cooling cycles obtaining extremely repeatable and predictable expansion and distribution from cycle to cycle
y Aluminum Body and feeder tubes to provide excellent resistance against formicary corrosion (ant nest corrosion)
y Designed and engineered to work with any size system
y Piston may be replaced to adjust flow and pressure drop
y This distributor can be used with a Thermostatic Expansion Valve (TXV) or Electronic Expansion Valve (EEV)
y Qualified for use with Danfoss TR6 TXV mechanical connection with long-tail fitting.
y Reduced weight compared to the Copper-Brass distributors
y U.L. listed. file No. SA 3449
y The Danfoss Eliminator-Distributor is designed to retrofit from piston expansion to TXV/EEV expansion or vice-versa
RD 3863 Series RD 3683 Series Internal detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
Construction
Body: Aluminum
Feeder Tubes: Aluminum
Piston:Extruded Brass
Teflon seated
Inlet tube: Copper
Nut: Brass
Seal: Teflon
Static Pressure
Burst: 2500 psi
Rated Working Pressure: 500 psi
Max Operating Temp: 450 °F (232 °C)
Refrigerant compatibility
Standard refrigerants:
R134a, R22, R404A / R507, R407C, and R410A
A
B
C
D
E
DKRCC.PK.FF0.A1.22 / 520H6635 7
Product Catalog RD 3863 Series Aluminum Distributor with Brass Piston
Ordering To order, indicate option choices for the following:
y Inlet option (Brass/Copper) (see fig. A)
y Piston Orifice Size
y Number of Circuits
y Feeder Tube Length
y Feeder Tube End Form
Ordering options
Straight Expanded Bell
Please make your selections in the column or space provided and fax or email your sales representative.
Contact your Danfoss sales representative for custom options.
Fig. A
Inlet option liquid line connection Indicate
Choice:ODM 3/8 ODF 3/8 Tube Length
3.875 in 3.375 in Long
3.375 in 3.0 in Medium
2.5 in 2.5 in Standard
N/A 1.125 in Short
Filter/strainer option available
Fig. D
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.188 in x 0.038 in Wall – 2 to 10 circuits
0.188 in x 0.050 in Wall – 2 to 10 circuits
Fig. E
Feeder Tube End Form Indicate Choice:
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
0.188 in – straight no end form
Contact Information:
OD – Outside Diameter
Fig. B
Fig. C
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Feeder Tube ength Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
Piston Orifice Size Indicate Choice:
see chart on page 18 Orifice No.
8 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog RD 5271 Series TXV Style Copper-Brass Distributor
Introduction
Features
Applications
Technical Data
The Thermostatic Expansion Valve (TXV) Style Copper-Brass Distributor is designed with an industry unique chamber enhancing active turbulence and improving even distribution of two phase refrigerants to each circuit.
Designed with the Chatleff Omni-Direct Closure for easy installation and service of TXV’s.
y Chatleff Omni-Direct Closure to insure 5 – 10 years of reliability on the mechanical connection, with a replaceable Teflon seal
y Designed and engineered to work with any size refrigeration system
y Can be mounted in any direction
y Operates effectively in both high andlow pressure systems
y Available with full assemblies with Thermostatic Expansion Valve (TXV) or Electronic Expansion Valve (EEV)
y Qualified for use with Danfoss TR6 valve mechanical connection with short-tail fitting
y UL Listed, File no. SA 3449
RD 5271 Series RD 5271 Series Internal detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
Construction
Body: Brass
Feeder Tubes: Copper
Threads: UNF 3/4-20
To be used with approved Teflon Seal
Static Pressure
Burst: 2500 psi
Rated Working Pressure: 500 psi
Max Operating Temp: 450 °F (232 °C)
Refrigerant compatibility
Standard refrigerants:
R134a, R22, R404A / R507, R407C, and R410A
A
B
C
D
E
DKRCC.PK.FF0.A1.22 / 520H6635 9
Product Catalog RD 5271 Series TXV Style Copper-Brass Distributor
Ordering To order, indicate option choices for the following:
y Inlet option (Brass/Copper) (see fig. A)
y Feeder Tube OD (Outside Diameter)
y Number of Circuits
y Feeder Tube Length
y Feeder Tube End Form
Ordering options
Fig. E
Please make your selections in the column or space provided and fax or email your sales representative.
Contact your Danfoss sales representative for custom options.
Fig. A
Inlet option liquid line connection Indicate
Choice:ODM 3/8 ODF 3/8 Tube Length
3.875 in 3.375 in Long
3.375 in 3.0 in Medium
2.5 in 2.5 in Standard
N/A 1.125 in Short
Screen option available
Fig. B
Distributor Connection
Omni Direct Mechanical Connection
Fig. D
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.144 in x 0.028 in Wall – 2 to 10 circuits
0.188 in x 0.028 in Wall – 2 to 8 circuits
Feeder Tube End Form Indicate Choice:
0.144 in – straight no end form
0.144 in – expanded Bell – 0.310 in OD
0.144 in – brazed on Bell – 0.375 in OD
0.188 in – straight no end form
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
Contact Information:
OD – Outside Diameter
Straight Expanded Bell
Brazed on Bell
Fig. C
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Feeder Tube ength Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
10 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog RD 5271 Series TXV Style Aluminum Distributor
Introduction
Features
Applications
Technical Data
The RD 5271 Series Thermostatic Expansion Valve (TXV) Style Aluminum Distributor is designed with an industry unique chamber enhancing active turbulence and improving even distribution of each circuit.
Designed with the Chatleff Omni-Direct Closure for easy installation and service of TXV’s.
y Chatleff Omni-Direct Closure to insure 5 – 10 years of reliability on the mechanical connection, with a replaceable Teflon seal
y Designed and engineered to work with any size residential system
y Can be mounted in any direction
y Operates effectively in both high and low pressure systems
y Aluminum Body and feeder tubes to provide excellent resistance against formicary corrosion
y Available with full assemblies with TXV or EEV
y Qualified for use with Danfoss TR6 TXV mechanical connection with short-tail fitting
y UL Listed, File no. SA 3449
RD 5271 TXV Series RD 5271 TXV Series Internal detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
Construction
Body: Aluminum
Feeder Tubes: Aluminum
Threads: UNF 3/4-20
To be used with approved Teflon Seal
Static Pressure
Burst: 2500 psi
Rated Working Pressure: 500 psi
Max Operating Temp: 450 °F (232 °C)
Refrigerant compatibility
Standard refrigerants:
R134a, R22, R404A / R507, R407C, and R410A
A
B
C
D
E
Straight Expanded Bell
DKRCC.PK.FF0.A1.22 / 520H6635 11
Product Catalog RD 5271 Series TXV Style Aluminum Distributor
Ordering To order, indicate option choices for the following:
y Inlet option
y Feeder Tube OD (Outside Diameter) and wall thickness
y Number of Circuits
y Tube Length
y End Form
Ordering options
Fig. E
Please make your selections in the column or space provided and fax or email your sales representative.
Contact your Danfoss sales representative for custom options.
Fig. A
Inlet option liquid line connection Indicate
Choice:ODM 3/8 ODF 3/8 Tube Length
3.875 in 3.375 in Long
3.375 in 3.0 in Medium
2.5 in 2.5 in Standard
N/A 1.125 in Short
Filter/strainer option available
Fig. B
Distributor Connection
Omni Direct Mechanical Connection
Fig. D
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.188 in x 0.038 in Wall – 2 to 10 circuits
0.188 in x 0.050 in Wall – 2 to 10 circuits
Feeder Tube End Form Indicate Choice:
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
0.188 in – straight no end form
Contact Information:
OD – Outside Diameter
Fig. C
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Feeder Tube ength Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
12 DKRCC.PK.FF0.A1.22 / 520H6635
Venturi area
Product Catalog RD 5500 Series Venturi Style Copper-Brass Distributort
Introduction
Features
Applications
Ordering To order, indicate option choices for the following (descriptions on following page):
y Inlet Options
y Feeder Tube OD (Outside Diameter)
y Number of Circuits
y Feeder Tube Length
y Feeder Tube End Form
y Available with sweat/braze inlets only
The Venturi Style Copper-Brass Distributor is designed for brazed connections. The RD 5500 Venturi series distributor can work in conjunction with an external expansion device for metering and distribution of the refrigerant.
y Designed and engineered to work with any size system
y Operates effectively in both high and low pressure systems
y Full assembly available with Thermostatic Expansion Valve (TXV) or Electronic Expansion Valve (EEV)
RD 5500 Series Venturi RD 5500 Series Venturi Internal detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
A
B
C
D
E
DKRCC.PK.FF0.A1.22 / 520H6635 13
Product Catalog RD 5500 Series Venturi Style Copper-Brass Distributor
Ordering options Please make your selections in the column or space provided and fax or email your sales representative.
Contact your Danfoss sales representative for custom options.
Fig. A
Tail Options Length Indicate Choice:
0.375 in ODF 2.5 in
0.5 in ODM 2.5 in
0.625 in ODM 2.5 in
Fig. B
Distributor Body Neck Size Option (no inlet tube)
Indicate Choice:
0.375 in
0.500 in
0.625 in
0.875 in
Fig. D
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.144 in x 0.028 in Wall – 2 to 14 circuits
0.157 in x 0.028 in Wall – 2 to 12 circuits
0.188 in x 0.028 in Wall – 2 to 12 circuits
0.250 in x 0.028 in Wall – 2 to 6 circuits
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Contact Information:
Fig. E
Feeder Tube End Form Indicate Choice:
0.144 in – straight no end form
0.144 in – expanded Bell – 0.310 in OD
0.144 in – brazed on Bell – 0.375 in OD
0.157 in – straight no end form
0.157 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
0.188 in – straight no end form
0.250 in – straight no end form
OD – Outside Diameter
Straight Expanded Bell
Brazed on Bell
Fig. C
Feeder Tube ength Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
14 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog RD 5500 Series Nozzle Style Distributor
Introduction
Features
Applications
Ordering To order, indicate option choices for the following (descriptions on following page):
y Inlet Options
y Nozzle Orifice Size
y Feeder Tube OD (Outside Diameter)
y Number of Circuits
y Feeder Tube Length
y Feeder Tube End Form
y Available with sweat/braze inlets only
The Nozzle Style Copper-Brass Distributor is designed for brazed connections. The nozzle allows for customizing of refrigerant flow to provide the desire performance of the system.
The RD 5500 Nozzle series distributor can work in conjunction with an external expansion device for metering and distribution of the refrigerant.
y Designed and engineered to work with any size system
y Operates effectively in both high and low pressure systems
y Full assembly available with Thermostatic Expansion Valve (TXV) or Electronic Expansion Valve (EEV)
RD 5500 Nozzle Style Series RD 5500 Nozzle Style Series Internal detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
Nozzle
A
B
C
F
E
D
DKRCC.PK.FF0.A1.22 / 520H6635 15
Product Catalog RD 5500 Series Nozzle Style Distributor
Ordering options Please make your selections in the column or space provided and fax or email your sales representative.
Fig. A
Tail Options Length Indicate Choice:
0.375 in ODF 2.5 in
0.5 in ODM 2.5 in
0.625 in ODM 2.5 in
Fig. B
Distributor Body Neck Size Option (no inlet tube)
Indicate Choice:
0.375 in
0.500 in
0.625 in
0.875 in
Fig. D
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.144 in x 0.028 in Wall – 2 to 14 circuits
0.157 in x 0.028 in Wall – 2 to 12 circuits
0.188 in x 0.028 in Wall – 2 to 12 circuits
0.250 in x 0.028 in Wall – 2 to 6 circuits
Fig. F
Feeder Tube End Form Indicate Choice:
0.144 in – straight no end form
0.144 in – expanded Bell – 0.310 in OD
0.144 in – brazed on Bell – 0.375 in OD
0.157 in – straight no end form
0.157 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
0.188 in – straight no end form
0.250 in – straight no end form
OD – Outside Diameter
Straight Expanded Bell
Brazed on Bell
Fig. E
Feeder Tube ength Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
Fig. C
Nozzle Orifice Size
Indicate Choice:
0.099 in
0.120 in
0.141 in
0.157 in
0.172 in
0.180 in
Nozzle Orifice Size
Indicate Choice:
0.199 in
0.219 in
0.221 in
0.242 in
0.266 in
0.281 in
Contact your Danfoss sales representative for custom options.
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Contact Information:
16 DKRCC.PK.FF0.A1.22 / 520H6635
Product Catalog RD 6500 Series Hot Gas Bypass Style Distributor
Introduction
Features
Applications
Ordering To order, indicate option choices for the following (descriptions on following page):
y Inlet options
y HGBP options
y Nozzle Orifice size
y Feeder Tube OD (Outside Diameter)
y Number of Circuits
The Hot Gas Bypass Style Distributor is the largest distributor body allowing up to 22 circuits with 0.144 OD tubing (other tube size options are available).
Can be used for heat pump and Hot Gas ByPass applications (HGBP).
y Available with or without HGBP port
y The HGBP is available for those applications where the load of the evaporator varies and the return air is lower than 72 °F / 50% RH
y Different nozzle sizes available for proper refrigerant mixing
y Full assembly available with Thermostatic Expansion Valve (TXV) or Electronic Expansion Valve (EEV)
RD 6500 Hot Gas Bypass Series RD 6500 Hot Gas Bypass Series Piston detail
For all multi-circuited HVAC and refrigeration heat exchangers used in residential and light commercial applications.
y Feeder Tube Length
y Feeder Tube End Form
y Available with sweat/braze inlets only
A
B
C
D
E
F
G
Straight Expanded Bell
Brazed on Bell
DKRCC.PK.FF0.A1.22 / 520H6635 17
Product Catalog RD 6500 Series Hot Gas Bypass Style Distributor
Ordering options Please make your selections in the column or space provided and fax or email your sales representative.
Fig. A
Inlet Option Liquid Line Indicate Choice:
Body Size Connection Size
0.875 in 0.50 in ODM
1.250 in 0.625 in ODM
1.625 in 0.625 in ODM
Fig. B
Distributor Body Neck Size Option Indicate
Choice:Body Size Connection Size
0.875 in 0.625 in
1.250 in 0.875 in
1.625 in 1.125 in
Fig. E
Feeder Tube Length Indicate Choice:
Available from 8 – 44 in (in increments of 2 in) Length:
Fig. F
Feeder Tube OD – Number of Circuits
Indicate Choice:
0.144 in x 0.028 in Wall – 2 to 22 circuits
0.157 in x 0.028 in Wall – 2 to 18 circuits
0.188 in x 0.028 in Wall – 2 to 18 circuits
0.250 in x 0.028 in Wall – 2 to 8 circuits
Fig. D
Nozzle Orifice Size
Indicate Choice:
0.120 in
0.141 in
0.157 in
0.172 in
0.199 in
Nozzle Orifice Size
Indicate Choice:
0.242 in
0.219 in
0.221 in
0.266 in
0.281 in
Fig. C
Side Port / Gas Port Indicate Choice:
Elbow 0.50 in ODF
Straigth 0.50 in ODF
Contact your Danfoss sales representative for custom options.
Name Job Title:
Company: Phone:
Email:
Address:
Quantity:
Comments:
Contact Information:
Fig. G
Feeder Tube End Form Indicate Choice:
0.144 in – straight no end form
0.144 in – expanded Bell – 0.310 in OD
0.144 in – brazed on Bell – 0.375 in OD
0.157 in – straight no end form
0.157 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.310 in OD
0.188 in – expanded Bell – 0.375 in OD
0.188 in – straight no end form
0.250 in – straight no end form
OD – Outside Diameter
18 DKRCC.PK.FF0.A1.22 / 520H6635 © Danfoss A/S (AC-MC/rds), 2012-10
Product Catalog Pistons
1) Orifice diameter has tolerance ± 0.001
Piston Orifice Selection Chart
Top View
Orifice diameter
Length
Teflon seal
Orifice No. Orifice [in] ± 0.0005
Length [in] ± 0.005
033 0.0330 0.500
035 0.0350 0.500
036 0.0360 0.500
037 0.0370 0.500
038 0.0380 0.500
039 0.0390 0.500
040 0.0400 0.500
041 0.0410 0.500
042 0.0420 0.500
043 0.0430 0.500
045 0.0453 0.500
046 0.0465 0.500
047 0.0469 0.500
048 0.0480 0.500
049 0.0492 0.500
051 0.0512 0.500
052 0.0520 0.500
053 0.0531 0.500
055 0.0550 0.500
057 0.0571 0.500
059 0.0591 0.500
060 0.0600 0.500
061 0.0610 0.500
062 0.0625 0.500
063 0.0630 0.500
064 0.0640 0.500
065 0.0650 0.500
067 0.0670 0.500
068 0.0680 0.500
070 0.0700 0.500
071 0.0709 0.500
072 0.0720 0.500
073 0.0730 0.500
074 0.0740 0.500
075 0.0748 0.500
076 0.0760 0.500
Orifice No. Orifice [in] ± 0.0005
Length [in] ± 0.005
077 0.0770 0.480
078 0.0781 0.480
079 0.0787 0.480
080 0.0807 0.480
081 0.0810 0.480
082 0.0820 0.480
083 0.0830 0.480
084 0.0846 0.480
086 0.0860 0.480
087 0.0866 0.480
088 0.0886 0.480
089 0.0890 0.480
090 0.0906 0.480
091 0.0910 0.480
092 0.0925 0.480
093 0.0938 0.480
094 0.0945 0.480
096 0.0960 0.480
098 0.0980 0.480
099 0.0995 0.480
101 0.1015 0.480
102 0.1024 0.480
104 0.1040 0.480
106 0.1065 0.480
108 0.1083 0.480
109 0.1093 0.480
110 0.1100 0.480
113 0.1130 0.480
116 0.1160 0.480
118 0.1181 0.480
120 0.12001) 0.470
125 0.12501) 0.470
128 0.12801) 0.470
DKRCC.PK.FF0.A1.22 / 520H6635 19
Product Catalog Danfoss Distributor Product Program
www.danfoss.us