GSPublisherEngine 1155.36.38.100 92 McCoy St, Booragoon E: [email protected] P: 9329 6888 600x1000 1000x1000 1200x1210 1200x1210 2143x2410SD 1200x1210 820 TF REMOTE CONTROL SECTIONAL DOOR 820L 820L 2x520 1st 820 TF 820L 1200x1210 600x610 OBS 2250x3000 2250x1590 WM REF REC UBO PTY PTY FW FW R.W.P. R.W.P. R.W.P. R.W.P. R.W.P. R.W.P. R.W.P. R.W.P. HP 21,000 6,000 BED 1 A: 8.12 m2 BED 2 A: 8.12 m2 GARAGE A: 21.09 m2 KITCHEN / DINING / LIVING A: 36.13 m2 BATH TILED A: 5.34 m2 LDRY VERANDAH A: 37.14 m2 ROBE A: 0.83 m2 ROBE A: 1.58 m2 R/H 12° SKILLION ROOF COLORBOND ROOF & GUTTERS SELECTED HARDIES CLADDING ALUMINIUM FRAMED WINDOWS & DOORS WITH FLYSCREENS & KEY LOCKS 100mm REINFORCED CONCRETE FLOOR 5° SKILLION ROOF 2 x BED - 80 m 2

2 x BED - 80m2€¦ · - wet area floors to be waterproofed in accordance with as3740 - 2010 "waterproofing of wet areas within residential buildings. - soakwells / stormwater in

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2 x BED - 80m2€¦ · - wet area floors to be waterproofed in accordance with as3740 - 2010 "waterproofing of wet areas within residential buildings. - soakwells / stormwater in

GSPublisherEngine 1155.36.38.100

92 McCoy St, BooragoonE: [email protected]: 9329 6888

600x10001000x1000

1200x1210

1200x12102143x2410SD1200x1210

820TF

REMO

TE C

ONTR

OLSE

CTIO

NAL D

OOR

820L

820L

2x5201st

820TF

820L

1200x1210

600x610OBS

2250x3000

2250x1590

WM

REFREC

UBO

PTYPTY

FW

FW

R.W.P. R.W.P.R.W.P. R.W.P.

R.W.P. R.W.P.R.W.P. R.W.P.

HP

21,000

6,000

BED 1A: 8.12 m2

BED 2A: 8.12 m2GARAGE

A: 21.09 m2

KITCHEN / DINING / LIVINGA: 36.13 m2

BATH TILED

A: 5.34 m2

LDRY

VERANDAHA: 37.14 m2

ROBEA: 0.83 m2

ROBEA: 1.58 m2

R/H

12° SKILLION ROOF

COLORBONDROOF & GUTTERS

SELECTED HARDIES CLADDING

ALUMINIUM FRAMEDWINDOWS & DOORSWITH FLYSCREENS& KEY LOCKS100mm REINFORCED

CONCRETE FLOOR

5° SKILLION ROOF

2 x BED - 80m2

Page 2: 2 x BED - 80m2€¦ · - wet area floors to be waterproofed in accordance with as3740 - 2010 "waterproofing of wet areas within residential buildings. - soakwells / stormwater in

SIGNATURES VARIATIONS

SHEET No:

CLIENT NAME:

SITE ADDRESS:

PO BOX 4459MYAREE BC WA 6960PHONE: 9329 6888BUILDERS REGISTRATION #11156EMAIL: [email protected]

SALES: COASTAL:

DRAWN: LDF DATE:

DATE: INT:26/03/18

MW NO

CLIMATE ZONE: WIND REGION:5 A

CLIENT: ............................................................./........../..........

COPYRIGHTThese plans and attached specifications are and shall always remain the sole

property of Granny Flats WA and must not be given, lent, resold, hired out, copied,or otherwise disposed of without the written permission of the company.

CLIENT: ............................................................./........../..........

BUILDER: .........................................................../........../..........

DATE: INT:26/03/18 LDF

VARIATIONS

JOB No.

DESIGN SKETCH PRADEEP

13 WESTBOURNE WAY,LYNWOOD.

XXXX

90

NOTES:- FOR SUPPLIED MATERIALS & LABOUR - REFER TO CONTRACT & DRAWINGS.- BUILDER TO VERIFY ALL DIMENSIONS, LEVELS & CONTOURS ON SITE BEFORE CONSTRUCTION.- DIMENSIONS ARE TO FRAME STUDS ONLY & DO NOT INCLUDE LININGS OR CLADDINGS- HEIGHTS ARE FROM TOP OF SLAB. NO ALLOWANCE MADE FOR FLOOR COVERINGS.- THE BUILDING CODE OF AUSTRALIA FORMS PART OF THESE DRAWINGS, ALL THE BCA REQUIREMENTS ARE TO APPLY INCLUDING THOSE NOT SHOWN OR MENTIONED HERE IN.- SMOKE DETECTOR TO BCA 3.7.2 AS INDICATED ON PLAN.- BUILDER IS TO PROVIDE ALL FLASHINGS AS NECESSARY TO WATERPROOF THE BUILDING.- COLORBOND GUTTERS & DOWNPIPES TO DISPERSE WATER TO GROUND LEVEL.- WET AREA FLOORS TO BE WATERPROOFED IN ACCORDANCE WITH AS3740 - 2010 "WATERPROOFING OF WET AREAS WITHIN RESIDENTIAL BUILDINGS.- SOAKWELLS / STORMWATER IN ACCORDANCE WITH BCA REQUIREMENTS & BUILDING PERMIT CONDITIONS TO BE UNDERTAKEN BY - OWNER- BW --------- DENOTES WALL BRACING 3kN CAPACITY TO 1684 - 2010.- EXTERNAL DOORS & OPENABLE WINDOWS SERVING HABITABLE ROOMS TO BE FITTED WITH WEATHER SEALS IN ACCORDANCE WITH BCA 3.12.3.3.- ALL WINDOWS TO BE IN ACCORDANCE WITH AS 2047 - 1999.- ROOF INSULATION - R2.0 ANTICON- CEILING INSULATION - R2.0 BATTS- EXTERNAL WALL INSULATION - R2.0 BATTS & INSULBREAK 65 - INTERNAL WALL INSULATION - R1.5 BATTS

2,143

943

2,1432,143

943

2,143

HARDIES PRIMELINE HERITAGEWEATHERBOARD CLADDINGFRONT

ELEVATION1:115.36

COLORBOND ROOF @ 10° PITCH

POSTS

820

600x

610

OBS

600x

610

OBS

1200

x150

0

1200

x150

0

1200

x181

021

43x1

810S

D12

00x1

810

2143

x181

0SD

820 LOH

820

820

820

820 LOH

REMO

TE C

ONTR

OLSE

CTIO

NAL D

OOR

FW

BED

1

R.W.P.

R.W.P.

GAS .HWU

BED 2

W

FWSHR

LIVING

ROBE

WS/

DW

S/D

WW

ROBE

BED

1BA

TH 1

BATH

2BE

D 2

KITC

HEN

/ DIN

ING

LIVIN

G

R.W.P.

R.W.P.

WM

SHRREFREC

UBO

REFREC

UBO

GAS HP

GAS HP

905,8

7390

5,858

90

5,000

12,00

0 OVE

RALL

BUI

LDIN

G

903,9

8390

1,800

901,7

8590

3,983

90

5,000

12,00

0 OVE

RALL

BUI

LDIN

G

6,825 OVERALL BUILDING 2,500

90 1,865 90 1,015 90

90 2,970 90 3,585 90

90 6,645 90

905,8

7390

5,858

90

903,3

9890

495

9090

495

903,3

9890

9011

,820

90

290

3,000

2,469

1,810

684

1,810

1,875

1,810

684

1,810

759

6,825 2,500

6,122

1,500

1,686

610

2,165

610

1,723

1,500

1,085

90 1,865 90 1,015 90 3,585 90

6,825 OVERALL BUILDING 2,50090 6,645 90

90 2,970 90 3,585 90

90 2,970 90 3,585 90

6,825 2,500

26

FLOORPLAN1:100

STOREL'DRY

SINGLE GARAGE

BATH 1 TILED

A: 5.40 m2

LIVINGA: 23.34 m2

KITCHENA: 12.69 m2

BATH 1 TILED

A: 5.40 m2

BED 1A: 13.79 m2

BED 2A: 13.79 m2

DININGA: 12.98 m2

BATH 2 TILED

A: 5.40 m2

VERANDAHFLAT LINED

A: 24.00 m2

AREA CALCULATIONSHOUSE

ROOF

OPTION 10

VDAHGARAGE

NOTE: GRANNY FLAT IS OVER70M2 AND EXCEEDS R CODES

REGULATIONSDESIGN IS SUBJECT TO

SHIRE APPROVAL

81.90M230.00M234.13M2154.53M2

Page 3: 2 x BED - 80m2€¦ · - wet area floors to be waterproofed in accordance with as3740 - 2010 "waterproofing of wet areas within residential buildings. - soakwells / stormwater in

SIGNATURES VARIATIONS

SHEET No:

CLIENT NAME:

SITE ADDRESS:

PO BOX 4459MYAREE BC WA 6960PHONE: 9329 6888BUILDERS REGISTRATION #11156EMAIL: [email protected]

SALES: COASTAL:

DRAWN: LDF DATE:

DATE: INT:26/03/18

MW NO

CLIMATE ZONE: WIND REGION:5 A

CLIENT: ............................................................./........../..........

COPYRIGHTThese plans and attached specifications are and shall always remain the sole

property of Granny Flats WA and must not be given, lent, resold, hired out, copied,or otherwise disposed of without the written permission of the company.

CLIENT: ............................................................./........../..........

BUILDER: .........................................................../........../..........

DATE: INT:26/03/18 LDF

VARIATIONS

JOB No.

DESIGN SKETCH PRADEEP

13 WESTBOURNE WAY,LYNWOOD.

XXXX

90

NOTES:- FOR SUPPLIED MATERIALS & LABOUR - REFER TO CONTRACT & DRAWINGS.- BUILDER TO VERIFY ALL DIMENSIONS, LEVELS & CONTOURS ON SITE BEFORE CONSTRUCTION.- DIMENSIONS ARE TO FRAME STUDS ONLY & DO NOT INCLUDE LININGS OR CLADDINGS- HEIGHTS ARE FROM TOP OF SLAB. NO ALLOWANCE MADE FOR FLOOR COVERINGS.- THE BUILDING CODE OF AUSTRALIA FORMS PART OF THESE DRAWINGS, ALL THE BCA REQUIREMENTS ARE TO APPLY INCLUDING THOSE NOT SHOWN OR MENTIONED HERE IN.- SMOKE DETECTOR TO BCA 3.7.2 AS INDICATED ON PLAN.- BUILDER IS TO PROVIDE ALL FLASHINGS AS NECESSARY TO WATERPROOF THE BUILDING.- COLORBOND GUTTERS & DOWNPIPES TO DISPERSE WATER TO GROUND LEVEL.- WET AREA FLOORS TO BE WATERPROOFED IN ACCORDANCE WITH AS3740 - 2010 "WATERPROOFING OF WET AREAS WITHIN RESIDENTIAL BUILDINGS.- SOAKWELLS / STORMWATER IN ACCORDANCE WITH BCA REQUIREMENTS & BUILDING PERMIT CONDITIONS TO BE UNDERTAKEN BY - OWNER- BW --------- DENOTES WALL BRACING 3kN CAPACITY TO 1684 - 2010.- EXTERNAL DOORS & OPENABLE WINDOWS SERVING HABITABLE ROOMS TO BE FITTED WITH WEATHER SEALS IN ACCORDANCE WITH BCA 3.12.3.3.- ALL WINDOWS TO BE IN ACCORDANCE WITH AS 2047 - 1999.- ROOF INSULATION - R2.0 ANTICON- CEILING INSULATION - R2.0 BATTS- EXTERNAL WALL INSULATION - R2.0 BATTS & INSULBREAK 65 - INTERNAL WALL INSULATION - R1.5 BATTS

600x

610

OBS

600x

610

OBS

1200

x150

0

1200

x150

0

1200

x181

021

43x1

810S

D12

00x1

810

2143

x181

0SD

820 LOH

820

820

820

820 LOH

FW

BED

1

R.W.P.

R.W.P.

GAS .HWU

BED 2

W

FWSHR

LIVING

ROBE

WS/

DW

S/D

WW

ROBE

BED

1BA

TH 1

BATH

/ LDR

YBE

D 2

KITC

HEN

/ DIN

ING

LIVIN

G

R.W.P.

R.W.P.

REFREC

UBO

REFREC

UBOWM

GAS HP

GAS HP

905,8

7390

5,858

90

12,00

0 OVE

RALL

BUI

LDIN

G

903,9

8390

1,800

901,7

8590

3,983

90

12,00

0 OVE

RALL

BUI

LDIN

G

6,825 OVERALL BUILDING 2,500

90 1,865 90 1,015 90

90 2,970 90 3,585 90

90 6,645 90

9011

,820

90

903,3

9890

495

9090

495

903,3

9890

9011

,820

90

759

1,810

684

1,810

1,875

1,810

684

1,810

759

6,825 2,500

4,308

610

2,215

610

1,673

1,500

1,085

90 1,955 1,015 90 3,585 90

6,825 OVERALL BUILDING 2,50090 6,645 90

90 2,970 90 3,585 90

90 2,970 90 3,585 90

6,825 2,500

25

FLOORPLAN1:100

BATH 1 TILED

A: 5.40 m2

LIVINGA: 23.34 m2

KITCHENA: 12.69 m2

BATH 1 TILED

A: 5.40 m2

BED 1A: 12.04 m2

BED 2A: 12.92 m2

DININGA: 12.98 m2

BATH/ LDRY TILED

A: 5.40 m2

VERANDAHFLAT LINED

A: 24.00 m2

2,143

943

2,1432,143

943

2,143

HARDIES PRIMELINE HERITAGEWEATHERBOARD CLADDING

COLORBOND ROOF @ 10° PITCH

POSTS

FRONTELEVATION1:115.36

AREA CALCULATIONSHOUSE

ROOF

OPTION 9

VDAH

NOTE: GRANNY FLAT IS OVER70M2 AND EXCEEDS R CODES

REGULATIONSDESIGN IS SUBJECT TO

SHIRE APPROVAL

81.90M230.00M2117.90M2

Page 4: 2 x BED - 80m2€¦ · - wet area floors to be waterproofed in accordance with as3740 - 2010 "waterproofing of wet areas within residential buildings. - soakwells / stormwater in

SIGNATURES VARIATIONS

SHEET No:

CLIENT NAME:

SITE ADDRESS:

PO BOX 4459MYAREE BC WA 6960PHONE: 9329 6888BUILDERS REGISTRATION #11156EMAIL: [email protected]

SALES: COASTAL:

DRAWN: LDF DATE:

DATE: INT:26/03/18

MW NO

CLIMATE ZONE: WIND REGION:5 A

CLIENT: ............................................................./........../..........

COPYRIGHTThese plans and attached specifications are and shall always remain the sole

property of Granny Flats WA and must not be given, lent, resold, hired out, copied,or otherwise disposed of without the written permission of the company.

CLIENT: ............................................................./........../..........

BUILDER: .........................................................../........../..........

DATE: INT:26/03/18 LDF

VARIATIONS

JOB No.

DESIGN SKETCH PRADEEP

13 WESTBOURNE WAY,LYNWOOD.

XXXX

90

NOTES:- FOR SUPPLIED MATERIALS & LABOUR - REFER TO CONTRACT & DRAWINGS.- BUILDER TO VERIFY ALL DIMENSIONS, LEVELS & CONTOURS ON SITE BEFORE CONSTRUCTION.- DIMENSIONS ARE TO FRAME STUDS ONLY & DO NOT INCLUDE LININGS OR CLADDINGS- HEIGHTS ARE FROM TOP OF SLAB. NO ALLOWANCE MADE FOR FLOOR COVERINGS.- THE BUILDING CODE OF AUSTRALIA FORMS PART OF THESE DRAWINGS, ALL THE BCA REQUIREMENTS ARE TO APPLY INCLUDING THOSE NOT SHOWN OR MENTIONED HERE IN.- SMOKE DETECTOR TO BCA 3.7.2 AS INDICATED ON PLAN.- BUILDER IS TO PROVIDE ALL FLASHINGS AS NECESSARY TO WATERPROOF THE BUILDING.- COLORBOND GUTTERS & DOWNPIPES TO DISPERSE WATER TO GROUND LEVEL.- WET AREA FLOORS TO BE WATERPROOFED IN ACCORDANCE WITH AS3740 - 2010 "WATERPROOFING OF WET AREAS WITHIN RESIDENTIAL BUILDINGS.- SOAKWELLS / STORMWATER IN ACCORDANCE WITH BCA REQUIREMENTS & BUILDING PERMIT CONDITIONS TO BE UNDERTAKEN BY - OWNER- BW --------- DENOTES WALL BRACING 3kN CAPACITY TO 1684 - 2010.- EXTERNAL DOORS & OPENABLE WINDOWS SERVING HABITABLE ROOMS TO BE FITTED WITH WEATHER SEALS IN ACCORDANCE WITH BCA 3.12.3.3.- ALL WINDOWS TO BE IN ACCORDANCE WITH AS 2047 - 1999.- ROOF INSULATION - R2.0 ANTICON- CEILING INSULATION - R2.0 BATTS- EXTERNAL WALL INSULATION - R2.0 BATTS & INSULBREAK 65 - INTERNAL WALL INSULATION - R1.5 BATTS

600x

610

OBS

600x

610

OBS

1200

x150

0

1200

x150

0

1200

x181

021

43x1

810S

D12

00x1

810

2143

x181

0SD

820 LOH

820

820

820

820 LOH

REFREC

FW

BED

1

R.W.P.

R.W.P.

GAS .HWU

UBO

BED 2

W

FWSHR

LIVING

ROBE

WS/

DW

S/D

WW

ROBE

BED

1BA

TH 1

BATH

/ LDR

YBE

D 2

KITC

HEN

/ DIN

ING

LIVIN

G

REFREC

UBOWM

GAS HP

GAS HP

905,8

7390

5,858

90

12,00

0 OVE

RALL

BUI

LDIN

G

903,9

8390

1,800

901,7

8590

3,983

90

12,00

0 OVE

RALL

BUI

LDIN

G

6,825 OVERALL BUILDING

90 1,865 90 1,015 90

90 1,865 90 1,015 90 3,585 90

90 6,645 90

9011

,820

90

903,3

9890

495

9090

495

903,3

9890

9011

,820

90

759

1,810

684

1,810

1,875

1,810

684

1,810

759

6,825

4,308

610

2,215

610

1,673

1,500

1,085

90 1,865 90 1,015 90 3,585 90

6,825 OVERALL BUILDING90 6,645 90

90 2,970 90 3,585 90

90 2,970 90 3,585 90

6,825

23

FLOORPLAN1:100

BATH 1 TILED

A: 5.40 m2

LIVINGA: 23.34 m2

KITCHENA: 12.69 m2

BATH 1 TILED

A: 5.40 m2

BED 1A: 12.04 m2

BED 2A: 13.79 m2

DININGA: 12.98 m2

BATH/ LDRY TILED

A: 5.40 m2

2,143

943

2,1432,143

943

2,143

HARDIES PRIMELINE HERITAGEWEATHERBOARD CLADDING

COLORBOND ROOF @ 10° PITCH

POSTS

FRONTELEVATION1:115.36

AREA CALCULATIONSHOUSEROOF

OPTION 8

NOTE: GRANNY FLAT IS OVER70M2 AND EXCEEDS R CODES

REGULATIONSDESIGN IS SUBJECT TO

SHIRE APPROVAL

81.90M293.90M2

Page 5: 2 x BED - 80m2€¦ · - wet area floors to be waterproofed in accordance with as3740 - 2010 "waterproofing of wet areas within residential buildings. - soakwells / stormwater in

SIGNATURES VARIATIONS

SHEET No:

CLIENT NAME:

SITE ADDRESS:

PO BOX 4459MYAREE BC WA 6960PHONE: 9329 6888BUILDERS REGISTRATION #11156EMAIL: [email protected]

SALES: COASTAL:

DRAWN: LDF DATE:

DATE: INT:26/03/18

MW NO

CLIMATE ZONE: WIND REGION:5 A

CLIENT: ............................................................./........../..........

COPYRIGHTThese plans and attached specifications are and shall always remain the sole

property of Granny Flats WA and must not be given, lent, resold, hired out, copied,or otherwise disposed of without the written permission of the company.

CLIENT: ............................................................./........../..........

BUILDER: .........................................................../........../..........

DATE: INT:26/03/18 LDF

VARIATIONS

JOB No.

DESIGN SKETCH PRADEEP

13 WESTBOURNE WAY,LYNWOOD.

XXXX

90

NOTES:- FOR SUPPLIED MATERIALS & LABOUR - REFER TO CONTRACT & DRAWINGS.- BUILDER TO VERIFY ALL DIMENSIONS, LEVELS & CONTOURS ON SITE BEFORE CONSTRUCTION.- DIMENSIONS ARE TO FRAME STUDS ONLY & DO NOT INCLUDE LININGS OR CLADDINGS- HEIGHTS ARE FROM TOP OF SLAB. NO ALLOWANCE MADE FOR FLOOR COVERINGS.- THE BUILDING CODE OF AUSTRALIA FORMS PART OF THESE DRAWINGS, ALL THE BCA REQUIREMENTS ARE TO APPLY INCLUDING THOSE NOT SHOWN OR MENTIONED HERE IN.- SMOKE DETECTOR TO BCA 3.7.2 AS INDICATED ON PLAN.- BUILDER IS TO PROVIDE ALL FLASHINGS AS NECESSARY TO WATERPROOF THE BUILDING.- COLORBOND GUTTERS & DOWNPIPES TO DISPERSE WATER TO GROUND LEVEL.- WET AREA FLOORS TO BE WATERPROOFED IN ACCORDANCE WITH AS3740 - 2010 "WATERPROOFING OF WET AREAS WITHIN RESIDENTIAL BUILDINGS.- SOAKWELLS / STORMWATER IN ACCORDANCE WITH BCA REQUIREMENTS & BUILDING PERMIT CONDITIONS TO BE UNDERTAKEN BY - OWNER- BW --------- DENOTES WALL BRACING 3kN CAPACITY TO 1684 - 2010.- EXTERNAL DOORS & OPENABLE WINDOWS SERVING HABITABLE ROOMS TO BE FITTED WITH WEATHER SEALS IN ACCORDANCE WITH BCA 3.12.3.3.- ALL WINDOWS TO BE IN ACCORDANCE WITH AS 2047 - 1999.- ROOF INSULATION - R2.0 ANTICON- CEILING INSULATION - R2.0 BATTS- EXTERNAL WALL INSULATION - R2.0 BATTS & INSULBREAK 65 - INTERNAL WALL INSULATION - R1.5 BATTS

600x

610

OBS

600x

610

OBS

1200

x150

0

1200

x150

0

1200

x181

021

43x1

810S

D12

00x1

810

2143

x181

0SD

820 LOH

820

820

820

820 LOH

FW

BED

1

R.W.P.

R.W.P.

GAS .HWU

BED 2

W

FWSHR

LIVING

ROBE

WS/

DW

S/D

WW

ROBE

BED

1BA

TH 1

BATH

2BE

D 2

KITC

HEN

/ DIN

ING

LIVIN

G

R.W.P.

R.W.P.

REFREC

UBO

REFREC

UBO

WM

SHR

GAS HP

GAS HP

905,8

7390

5,858

90

12,00

0

903,9

8390

1,800

901,7

8590

3,983

90

12,00

0 OVE

RALL

BUI

LDIN

G

6,825 2,500

90 1,865 90 1,015 90

90 2,970 90 3,585 90

90 6,645 90

9011

,820

90

903,3

9858

590

9058

53,3

9890

9011

,820

90

759

1,810

684

1,810

1,375

1,810

684

1,810

1,259

6,825

4,308

610

2,215

610

1,673

1,500

1,085

90 1,865 90 1,015 90 3,585 90

6,825 OVERALL BUILDING 2,50090 6,645 90

90 2,970 90 3,585 90

90 2,970 90 3,585 90

6,825 2,500

27

FLOORPLAN1:100

BATH 1 TILED

A: 5.40 m2

LIVINGA: 23.34 m2

KITCHENA: 12.69 m2

BATH 1 TILED

A: 5.40 m2

BED 1A: 12.04 m2

BED 2A: 12.92 m2

DININGA: 12.98 m2

BATH 2 TILED

A: 5.40 m2

VERANDAHFLAT LINED

A: 24.00 m2

DRYERREC

2,143

943

2,1432,143

943

2,143

HARDIES PRIMELINE HERITAGEWEATHERBOARD CLADDING

COLORBOND ROOF @ 10° PITCH

POSTS

FRONTELEVATION1:115.36

AREA CALCULATIONSHOUSE

ROOF

OPTION 11

VDAH

NOTE: GRANNY FLAT IS OVER70M2 AND EXCEEDS R CODES

REGULATIONSDESIGN IS SUBJECT TO

SHIRE APPROVAL

84.93M227.19M2117.90M2