73

2 - hermestrading.com.lbhermestrading.com.lb/wp-content/uploads/2015/10/Zelio-Time.pdf · 2/4 2 Presentation 2 Zelio Time - timing relays 2 Presentation A timing relay is a component

Embed Size (px)

Citation preview

2/0

2/1

Contents 0

2

2 - Zelio Time - timing relays

Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/2

� Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/4

� Choice, functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/6

Modular relays, solid state output,width 17.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/14

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/16

Industrial single or multifunction relays, solid state output, width 22.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/18

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/20

Modular relays, relay output, width 17.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/22

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/24

Industrial single, dual or multifunction relays, relay output, width 22.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/28

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/30

Industrial single-function, relays, optimum, relay output, width 22.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/42

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/44

Universal plug-in relays, relay output, width 35 mm� Plug-in relays 11-pin

� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/48

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/50

� Plug-in relays 8-pin

� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/52

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/54

Miniature plug-in relays, relay output� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/56

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/57

Electronic relays, relay output, 48 x 48 housing� Presentation, description, characteristics, functions . . . . . . . . . . . . . . . page 2/58

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/63

Panel-mounted, plug-in, universal relays� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2/66 and 2/70

� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2/69 and 2/71

2/2

2

Selection guide 2 Zelio Time - timing relays 2

Applications These timing relays enable simple automation cycles to be set up using wired logic.They can also be used to complement the functions of PLCs.

Output Solid stateTiming relays with solid state output reduce the amount of wiring required (wired in series). The durability of these timing relays is independent of the number of operating cycles.

RelayRelay outputs provide complete isolation between the supply and outut circuits.It is possible to have several output circuits.

Type Modular Industrial Modular Industrial

Timing ranges 7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

1 or 2 ranges,depending on model :10 s, 30 s, 300 s, 60 min

Depending on model :6 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

Depending on model :4 ranges :0.6 s, 2.5 s, 20 s, 160 s7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h7 ranges :1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 10 min10 ranges :1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 30 min, 300 min, 30 h, 300 h

Relay type RE11 L���� RE9 RE11 R���� RE 88 865 ���

RE7Pages 2/16 and 2/17 2/20 2/24 to 2/27 2/30 to 2/33

and 2/36 to 2/39

2/3

2

22

These timing relays enable simple automation cycles to be set up using wired logic.They can also be used to complement the functions of PLCs.

RelayRelay outputs provide complete isolation between the supply and output circuits.It is possible to have several output circuits.

Optimum Plug-in Panel-mounted

Universal Miniature Analogue Digital

1 range,depending on model :0.5 s, 3 s, 10 s, 30 s, 300 s, 30 min

7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

7 ranges :0,1 s...1 s1 s...10 s0,1 min...1 min1 min...10 min0,1 h...1 h1 h...10 h10 h...100 h

14 ranges :1,2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h

Depending on model :7 ranges :99.99 s, 999.99 s, 99 min 59 s, 99.99 min, 999.9 min,99 h 59 min, 999.9 h11 ranges :99.99 s, 999.99 s, 9999 s, 99 min 59 s, 99.99 min,999.9 min, 9999 min,99 h 59 min, 99,99 h,999.9 h, 9999 h

RE8 RE 88 867 ��� RE XL�TM�� RE 48A ��� RE 88 857 ���

2/44 to 2/47 2/48 to 2/55 2/56 and 2/57 2/58 to 2/65 2/66 to 2/71

2/4

2

Presentation 2 Zelio Time - timing relays 2

PresentationA timing relay is a component which is designed for timing events in industrial automation systems by closing or opening contacts before, during or after a set timing period.

There are two main 'families' of timing relays: � “DIN rail mounted” relays (RE7, RE8, RE9, RE11, RE XL…) designed for mounting on DIN rails in an enclosure,

� “Panel mounted” relays type RE 48A, designed for mounting on the front of a panel to give users easy access to the settings.

These relays have one, two or four outputs. Sometimes the second output can be either timed or instantaneous.If the power is switched off during the timing period, the relay reverts to its initial position.

Application examples:� opening of automatic doors,� alarm,� lighting in toilets,� car park barriers ...

Definitions The following definitions will assist in understanding the operation of these relays: � Relay output:This is the most common type of output. When the relay is energised, the moving armature is attracted by the coil and so actuates the contacts, which change state. When the relay is de-energised, both the armature and the contacts revert to their initial position.This type of output allows complete isolation between the supply and the output.

There are three types of output: ��C/O: changeover contact, i.e. when the relay is de-energised, the circuit between the common point C and N/C is closed and when the relay is operating (coil energised), it closes the circuit between the common point C and N/O.

��N/C: a contact that is closed without being actuated is called a Normally Closed (N/C) contact.

��N/O: a contact that closes when actuated is called a Normally Open (N/O) contact.

� Solid state output:These outputs are entirely electronic and involve no moving parts; service life is therefore increased.

� Breaking capacity:The current value that a contact is capable of breaking in specified conditions.

� Mechanical durability:The number of mechanical operating cycles of the contact or contacts.

� Minimum switching capacity (or minimum breaking capacity): corresponds to the minimum required current which can flow through the contacts of a relay.

� G (Gate) input : Gate input allows timing in progress to be interrupted without resetting it.

RE11

5219

31-1

2-M

RE7 RL13BU

5609

04

RE 48A

5219

38-4

4-M

RE XL

5325

35

CNO

NC

NC

NO

2/5

2

Presentation (continued) 2 Zelio Time - timing relays 2

Definitions (continued)Functions

Timing functions are identified by letters.Main timing functions

Complementary functions (1)

Definitions

A (2) Delay on energisation

Ac Timing after closing and opening of control contact

Ad Timing on closing of control contact

Ah Flashing single cycle by operation of control contact

Ak Asymmetrical On-delay and Off-delay with external control

At Delay on energisation with memory

Aw Off-delay on energisation or on opening of control contact

B (2) Timing on impulse, one shot

Bw Pulse output (width adjustable)

C (2) Timing after opening of control contact

D (2) Symmetrical flashing, start with output in rest position

Di (2) Symmetrical flashing, start with output in operating position

H (2) Timing on energisation

He Pulse-on de-energisation

Ht Timing on energisation with memory

K Delay on de-energisation (without auxiliary supply)

L (2) Asymmetrical flashing, start with output in rest position

Li (2) Asymmetrical flashing, start with output in operating position

Lt Asymmetrical flashing with partial stop of timing

N Safe-guard

O Delayed safe-guard

P Delayed fixed-length pulse

Pt Impulse counter (on-delay)

Qc Star-delta timing

Qe Star-delta timing

Qg Star-delta timing

Qt Star-delta timing

T Bistable relay

Tt Timed impulse relay

W On-delay after opening of control contact

(1) Complementary functions enhance the main timing functions.Example: Ac: timing after closing and opening of control contact.

(2) The most commonly used timing functions.

2/6

2

Selection 2 Zelio Time - timing relays 2

Selection tableSelection criteria� Functions (On-delay or Off-delay, counter, flashing…)� Supply voltage (example: �/� 12 V…240 V).� Timing range (example: 0.05 s…100 h)� Type of output (contact or solid state) and required Number of contacts.� Breaking capacity or Rated current of contacts, expressed in Amperes.This is the maximum current which may flow through the contacts.

Functions Supply voltage Timing range Type of output Rated current

Relay Page

A � 12 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMJD 2/57

0.1 s …100 h 4 C/O contacts 3 A RE XL4TMJD 2/57� 24 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMBD 2/57

0.1 s…100 h 4 C/O contacts 3 A RE XL4TMBD 2/57

� 24 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMB7 2/570.1 s…100 h 4 C/O contacts 3 A RE XL4TMB7 2/57

� 120 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMF7 2/57

0.1 s…100 h 4 C/O contacts 3 A RE XL4TMF7 2/57� 230 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMP7 2/57

0.1 s…100 h 4 C/O contacts 3 A RE XL4TMP7 2/57

�/� 24…240 V 0.1 s…10 s 1 solid state output 0.7 A RE9 TA11MW 2/200.3 s…30 s 0.7 A RE9 TA31MW 2/203 s…300 s 0.7 A RE9 TA21MW 2/20

40 s…60 min 0.7 A RE9 TA51MW 2/201 s…100 h 0.7 A RE11 LA MW 2/160.02 s…300 h 2 timed C/O contacts 5 A RE 48A TM12 MW 2/58

�/� 24 V, � 110…240 V 0.05 s…300 h 1 C/O contact 8 A RE7 TL11BU 2/360.1 s…3 s 8 A RE8 TA61BUTQ 2/440.1s…10 s 8 A RE8 TA11BUTQ 2/44

0.3 s…30 s 8 A RE8 TA31BUTQ 2/443 s…300 s 8 A RE8 TA21BUTQ 2/4420…30 min 8 A RE8 TA41BUTQ 2/44

�/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 2 C/O contacts 8 A RE7 TP13BU 2/38

A, Ac, At, B, Bw, C, D, Di, H, Ht � 24…240 V 1 s…100 h 1 solid state output 0.7 A RE11 LM BM 2/17�/� 12 V 1 s…100 h 1 C/O contact 8 A RE11 RM JU 2/27�/� 12…240 V 1 s…100 h 1 C/O contact 8 A RE11 RM MW 2/26

1 s…100 h 8 A RE11 RM MWS 2/27� 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RM MU 2/26

A, At � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RA MU 2/24

A, At, Aw � 110…240 V, �/� 24 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 TM11BU 2/36

A, At, B, C, D, Di, H, Ht � 24 V, � 24…240 V 1 s…10 h 1 C/O contact 5 A RE11 RME MU 2/27

A, B, C, Di �/� 24…240 V 0.02 s…300 h 2 timed C/O contacts 5 A RE 48A ML12 MW 2/63

A, C, D, Di, H, Qg, Qt, W � 110…240 V, �/� 24 V, �/� 42…48 V

0.05 s…300 h 2 C/O contacts 8 A RE7 MY13BU 2/39

�/� 24…240 V 0.05 s…300 h 2 C/O contacts 8 A RE7 MY13MW 2/39

A, C, D, Di, H, W � 110…240 V, �/� 24 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 ML11BU 2/36

A, D, Di, H �/� 24…240 V� 24…240 V

0.1 s…10 s et 3 s…300 s

1 solid state output 0.7 A RE9 MS21MW 2/20

A1, A2, H1, H2 �/� 24…240 V 0.02 s…300 h 2 C/O contacts 5 A RE 48A MH13 MW 2/63

Ac � 110…240 V, �/� 24 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 MA11BU 2/360.05 s…300 h 2 C/O contacts 8 A RE7 MA13BU 2/38

Ad, Ah, N, O, P, Pt, TI, Tt, W � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RMX MU 2/27

Ak � 110…240 V, �/� 24 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 MV11BU 2/36

2/7

2

Selection (continued) 2 Zelio Time - timing relays 2

Selection table (continued)Functions Supply voltage Timing range Type of output Rated

currentRelay Page

B � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RB MU 2/25

C �/� 24 V 0.1 s…10 s 1 C/O contact 8 A RE8 RA11BTQ 2/440.3 s…30 s 8 A RE8 RA31BTQ 2/443 s…300 s 8 A RE8 RA21BTQ 2/44

� 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RC MU 2/25� 110…240 V 0.1 s…10 s 1 C/O contact 8 A RE8 RA11FUTQ 2/44

0.3 s…30 s 8 A RE8 RA31FUTQ 2/44

3 s…300 s 8 A RE8 RA21FUTQ 2/4420 s…30 min 8 A RE8 RA41FUTQ 2/44

�/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 RA11BU 2/37

0.05 s…300 h 8 A RE7 RM11BU 2/370.05 s…300 h 2 C/O contacts 8 A RE7 RL13BU 2/38

� 24…240 V 0.1 s…10 s 1 solid state output 0.7 A RE9 RA11MW7 2/20

0.3 s…30 s 0.7 A RE9 RA31MW7 2/203 s…300 s 0.7 A RE9 RA21MW7 2/2040 s…60 min 0.7 A RE9 RA51MW7 2/20

1 s…100 h 0.7 A RE11 LC BM 2/17D �/� 24 V, � 110…240 V 0.05 s…300 h 1 C/O contact 8 A RE7 CL11BU 2/37

0.1 s…10 s 8 A RE8 CL11BUTQ 2/45

�/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 2 C/O contacts 8 A RE7 CP13BU 2/39

H �/� 24 V, � 110…240 V 0.05 s…300 h 1 C/O contact 8 A RE7 PE11BU 2/370.1 s…10 s 8 A RE8 PE11BUTQ 2/460.3 s…30 s 8 A RE8 PE31BUTQ 2/46

3 s…300 s 8 A RE8 PE21BUTQ 2/46�/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 2 C/O contacts 8 A RE7 PP13BU 2/39

� 24…240 V 1 s…100 h 1 solid state output 0.7 A RE11 LH BM 2/16H, Ht � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RH MU 2/24

He �/� 24 V, � 110…240 V 0.05 s…0.5 s 1 C/O contact 8 A RE8 PT01BUTQ 2/47

K �/� 24…240 V 0.05 s…10 min 1 C/O contact 5 A RE7 RB11MW 2/37

�/� 24 V, � 110…240 V 0.05 s…0.5 s 1 C/O contact 8 A RE8 RB51BUTQ 2/450.1 s…10 s 8 A RE8 RB11BUTQ 2/450.3 s…30 s 8 A RE8 RB31BUTQ 2/45

�/� 24…240 V 0.05 s…10 min 2 C/O contacts 5 A RE7 RB13MW 2/38L, Li � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RL MU 2/25

� 24…240 V 1 s…100 h 1 solid state output 0.7 A RE11 LL BM 2/17

�/� 12 V 1 s…100 h 1 C/O contact 8 A RE11 RL JU 2/25�/� 24…240 V 0.02 s…300 h 2 timed C/O contacts 5 A RE 48A CV12 MW 2/63

L, Li, Lt � 110…240 V, �/� 24 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 CV11BU 2/37

Qc �/� 24 V, � 110…240 V 0.1 s…10 s 1 C/O contact 8 A RE8 YG11BUTQ 2/47

0.3 s…30 s 8 A RE8 YG31BUTQ 2/473 s…300 s 8 A RE8 YG21BUTQ 2/47

Qe �/� 24 V 0.3 s…30 s 1 NO + 1 NC 8 A RE8 YA32BTQ 2/47

� 110…240 V 0.3 s…30 s 1 NO + 1 NC 8 A RE8 YA32FUTQ 2/47� 380…415 V 0.3 s…30 s 1 NO + 1 NC 8 A RE8 YA32QTQ 2/47

Qg �/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 1 NO + 1 NC 8 A RE7 YR12BU 2/39

Qt �/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 2 C/O contacts 8 A RE7 YA12BU 2/39

W �/� 24 V 0.1 s…10 s 1 C/O contact 8 A RE8 PD11BTQ 2/46

0.3 s…30 s 8 A RE8 PD31BTQ 2/463 s…300 s 8 A RE8 PD21BTQ 2/46

� 110…240 V 0.1 s…10 s 1 C/O contact 8 A RE8 PD11FUTQ 2/46

0.3 s…30 s 8 A RE8 PD31FUTQ 2/463 s…300 s 8 A RE8 PD21FUTQ 2/46

�/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 2 C/O contacts 8 A RE7 PD13BU 2/39

W, Ht �/� 24 V, � 110…240 V, �/� 42…48 V

0.05 s…300 h 1 C/O contact 8 A RE7 PM11BU 2/37

2/8

2

Functions 2 Zelio Time - timing relays 2

FunctionsU : SupplyR : Relay or solid state outputR1/R2 : 2 timed outputsR2 inst. :The second output is instantaneous if the right position is selectedT : Timing periodC : Control contactG : GateTa : Adjustable On-delayTr : Adjustable Off-delay

Function diagram:Relay de-energised

Relay energised

Output open

Output closed

Function A : Delay on energisation1 output 2 outputs

The timing period T begins on energisation.After timing, the output(s) R close(s).The second output can be either timed or instantaneous.

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Ac: Timing after closing and opening of control contact1 output 2 outputs

After power-up, closing of the control contact C causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes.When control contact C re-opens, the timing T starts.At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).The second output can be either timed or instantaneous.

T = t1 + t2 + …T = t’1 + t’2 + …

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Ad: Timing on closing of control contact.

After power-up, pulsing or maintaining of control contact C starts the timing T. At the end of this timing period T, the output R closes. The output R will be reset the next time control contact C is pulsed or maintained.

Function Ah: Flashing single cycle by operation of control contact

After power-up, pulsing or maintaining of control contact C starts the timing T.A single cycle then starts with 2 timing periods T of equal duration (start with output in rest position)Output R closes at the end of the first timing period T and reverts to its initial position at the end of the second timing period T.Control contact C must be reset in order to re-start the single flashing cycle.

U

R

T

U

R1/R2

TR2 inst.

U

C

t1

G

R

t'1t2 t'2

U

C

R1/R2

T T

R2 inst.

U

R

C

T T

U

R

C

TT T T

2/9

2

Functions (continued) 2 Zelio Time - timing relays 2

Function Ak: Asymmetrical On-delay and Off-delay with external control

After power-up and closing of the control contact C, timing starts for a period Ta (timing can be interrupted by operating the Gate control contact G).At the end of this timing period Ta, the output R closes.Opening of control contact C causes a second timing period Tr to start (timing can be interrupted by operating the Gate control contact G).At the end of this timing period Tr, the output R reverts to its initial state.

Ta = t1 + t2 + …Tr = t’1 + t’2 + …Function At: Delay on energisation with memory

After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact C closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.

T = t1 + t2 + …Function Aw: Off-delay on energisation or on opening of control contact

The timing period T starts on energisation.At the end of the timing period T, the output R closes.Closing of the control contact C makes the output R open. Opening of control contact C restarts timing period T.At the end of timing period T, the output R closes.

Function B: Timing on impulse, one shot

After power-up, pulsing or maintaining control contact C starts the timing T.The output R closes for the duration of the timing period T then reverts to its initial state.

Function Bw: Pulse output (width adjustable)

On closing and opening of control contact C, the output R closes for the duration of the timing period T.

U

C

t1

G

R

t'1t2 t'2

U

R

C

t1 t2

U

R

C

T T

U

R

C

T T

U

R

C

T T

2/10

2

Functions (continued) 2 Zelio Time - timing relays 2

Function C: Timing after opening of control contact1 output 2 outputs

After power-up and closing of the control contact C, the output R closes.When control contact C re-opens, timing T starts.At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function D: Symmetrical flashing, start with output in rest position1 output 2 outputs

Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.The second output can be either timed or instantaneous.

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Di: Symmetrical flashing, start with output in operating position1 output 2 outputs

Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.The second output can be either timed or instantaneous.

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function H: Timing on energisation1 output 2 outputs

On energisation of the relay, timing period T starts and the output(s) R close(s).At the end of the timing period T, the output(s) R revert(s) to its/their initial state.The second output can be either timed or instantaneous.

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

U

C

R

T

U

R1/R2

C

TR2 inst.

T T T T T T

U

R

U

R1/R2

T T T T T TR2 inst.

T T T T T

U

R

U

R1/R2

T T T T TR2 inst.

U

R

T

U

R1/R2

TR2 inst.

2/11

2

Functions (continued) 2 Zelio Time - timing relays 2

Function He: Pulse-on de-energisation

On de-energisation, the output R closes for the duration of a timing period T.

Function Ht: Timing on energisation with memory

On energisation, the output R closes for the duration of a timing period T then reverts to its initial state.Pulsing or maintaining control contact C will again close the output R.Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 + … .The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its initial state.

T = t1 + t2 + …Function K: Delay on de-energisation (without auxiliary supply)1 output 2 outputs

On energisation, the output(s) R close(s).On de-energisation, timing period T starts and, at the end of this period, the output(s) R revert(s) to its/their initial state.

Function L: Asymmetrical flashing, start with output in rest position

Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the output R.

Function Li: Asymmetrical flashing, start with output in operating position

Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the output R.

Function Lt: Asymmetrical flashing with partial stop of timing

Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the output R.Gate control contact G can be operated to partially stop timing periods Ta and Tr.

Tr = t1 + t2 + … Ta = t’1 + t’2 + …

U

R

> 80 ms 80 msT < T

U

R

C

t1 t2T

U

R

T

U

R1

R2

T

Tr Ta

U

R

Ta Tr

U

R

R

G

t1 t'2t2 t'1

U

2/12

2

Functions (continued) 2 Zelio Time - timing relays 2

Function N: Safe-guard

After power-up and an initial control pulse C, the output R closes.If the interval between two control pulses C is greater than the set timing period T, timing elapses normally and the output R closes at the end of the timing period. If the interval is not greater than the set timing period, the output R remains closed until this condition is met.

Function O: Delayed safe-guard

An initial timing period T begins on energisation. At the end of this timing period, the output R closes. As soon as there is a control pulse C, the output R reverts to its initial state and remains in that state until the interval between two control pulses is less than the value of the set timing period T. Otherwise, the output R closes at the end of the timing period T.

Function P: Delayed fixed-length pulse

The timing period T begins on energisation.At the end of this period, the output R closes for a fixed time P.

Function Pt: Impulse counter (on-delay)

On energisation, timing period T starts (it can be interrupted by operating the Gate control contact G).At the end of this period, the output R closes for a fixed time P.

Function Qc: Star-delta timing

On energisation, the star contact closes instantaneously and timing starts. At the end of the timing period, the star contact opens.After a 50 ms pause, the delta contact closes and remains in this position.

Function Qe: Star-delta timing

Timing for star-delta starter with contact for switching to star connection.

T

U

C

R

T T T

U

C

Rt<T

U

R

T P

P = 500 ms

t1 t2 P

U

G

R

T = t1 + t2 + …P = 500 ms

T 50 ms

U

R

T 80 ms

U

R1

R2

2/13

2

Functions (continued) 2 Zelio Time - timing relays 2

Function Qg: Star-delta timing

Timing for star-delta starter with contact for switching to star connection.

Function Qt: Star-delta timing

Timing for star-delta starter with double On-delay period.

Function T: Bistable relay

After power-up, pulsing or maintaining of control contact C switches the output on.A second pulse on the control contact C switches the output R off.

Function Tt: Timed impulse relay

After power-up, pulsing or maintaining of control contact C switches output R on and starts timing T.The output switches off at the end of the timing period T or following a second pulse on the control contact C.

Function W: On-delay after opening of control contact1 output 2 outputs

After power-up and opening of the control contact, the output(s) close(s) for a timing period T.At the end of this timing period the output(s) revert(s) to its/their initial state.The second output can be either timed or instantaneous.

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

T T

50 ms

U

R1

R2

U

R1

R2

T T

50 ms

U

C

R

U

C

R

T t<T

T

U

C

R

U

C

R1/R2

TR2 inst.

2/14

2

Characteristics 2 Zelio Time -modular timing relays 2

Relays with solid state output, width 17.5 mm

Timing characteristicsSelectable timing rangesby selector switch on front panel

s 0.1…1 1…10

min 0.1…1

1…10h 0.1…1

1…10

10…100Repeat accuracy(with constant parameters)

Conforming to IEC 61812-1 ± 0.5 %

Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V

Setting accuracy at full scale

Conforming to IEC 61812-1 ± 10 % at 25 °C

Minimum duration of control pulse

Typical ms 50

Maximum reset time by de-energisation

Typical ms 350

Immunity to microbreaks Typical ms > 10

Supply characteristicsSupply voltage

VDepending on version:� 24…240�/��24…240

Frequency Hz 50/60

Operating range 85…110 % UnOn-load factor 100 %

Maximum power consumption

Depending on model

� 24 V W 0.6

� 240 V W 1.5 � 240 V VA 32

Output characteristicsOutput type Solid state

Breaking capacity A �/��0.7 at 20° C (0.5 A UL)

Derating mA 5 / °CMaximum permissible current A 20 ≤ 10 ms

Minimum breaking current mA 10 Leakage current mA < 5

Maximum switching voltage V �/��250

Typical voltage drop at terminals 3-wire 4 V - 2-wire 8 V

Electrical life 108 operationsMechanical life 108 operations

Dielectric strength Conforming to IEC 60664, IEC 60255-5

kV 2.5...1 mA / 1 min

Input characteristicsInput type Volt-free contact (no potential)

Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer

References :pages 2/16 and 2/17

Dimensions :page 2/16

Schemes :page 2/17

2/15

2

Characteristics (continued) 2 Zelio Time -modular timing relays 2

Relays with solid state output, width 17.5 mm

General characteristicsConforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC

(� marking) + EMC directive (89/336/EEC + IEC 60669-2-3)

Approvals cULus, CSAAmbient air temperature around the device

Storage °C - 30…+ 60

Operation °C - 20…+ 60Creepage distance and clearance

Conforming to IEC 60664-1 kV 4 kV/3

Degree of protectionconforming to IEC 60529

Terminal block IP 20Housing IP 40

Front panel IP 50

Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 HzA = 0.35 mm

Relative humidity without condensation

Conforming to IEC 60068-2-3 93 %

Electromagnetic compatibility

Immunity to electrostatic discharge, conforming to IEC 61000-4-2

Level III (Air 8 kV/Contact 6 kV)

Immunity to electromagnetic fields,conforming to ENV 50140/204 (IEC 61000-4-3)

Level III (10 V/m: 80 MHz…1 GHz)

Immunity to fast transients in bursts, conforming to IEC 61000-4-4

Level III (direct 2 kV / capacitive connecting clip 1 kV)

Immunity to surges on the power supply, conforming to IEC 61000-4-5

Level III (common mode 2 kV / differential mode 1 kV)

Immunity to radio frequency interference in common mode,conforming to ENV 50141 (IEC 61000-4-6)

Level III (10 V rms: 0.15…80 MHz)

Immunity to voltage dips and breaks,conforming to IEC 61000-4-11

30 % / 10 ms

60 % / 100 ms95 % / 5 s

Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)

Class B

Fixing Symmetrical mounting rail (EN 50022)

mm 35

Clamping capacity Without cable end mm2 2 x 2.5 or 1 x 4With cable end mm2 2 x 1.5

Housing material Self-extinguishing

References :pages 2/16 and 2/17

Dimensions :page 2/16

Schemes :page 2/17

2/16

2

Functions,references,dimensions,schemes 2

Zelio Time -modular timing relays 2

Relays with solid state output, width 17.5 mm

Solid state output� Multifunction, dual function or single function� Multi-range (7 selectable ranges)� Multivoltage� Solid state output: 0.7 A� Screw terminals

Function diagramsFunction A Function H

Delay on energisation

Timing on energisation

References

Functions Single function Single functionA H

Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hVoltages � 24…240 V – RE11 LH BM

�/� 24…240 V RE11 LA MW –Nominal output current 0.7 A 0.7 AConnection Screw terminals � �

Weight (kg) 0.060 0.060

Dimensions and connection schemesDimensions

U

RT

U

R

C

t1 t2T

5219

25

5219

25

5,5

72

17,9

81

Characteristics :pages 2/14 and 2/15

Schemes :page 2/17

2/17

2

22

Function At Function B Function C Function L Function LiDelay on energisation with memory

T = t1 + t2 + …

Timing on impulse, one shot

Timing after opening of control contact

Asymmetrical flashing, start with output in rest position

Asymmetrical flashing, start with output in operating position

Function Ht Function D Function Di Function Ac Function BwTiming on energisation with memory

T = t1 + t2 + …

Symmetrical flashing, start with output in rest position

Symmetrical flashing, start with output in operating position

Timing after closing and opening of control contact

Pulse output (width adjustable)

Single function Dual function MultifunctionC L - Li A - At - B - C - H - Ht - D - Di - Ac - Bw

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hRE11 LC BM RE11 LL BM RE11 LM BM– – –

0.7 A 0.7 A 0.7 A� � �

0.060 0.060 0.060

Connection schemesSingle function relay Multifunction relay Flashing

Functions A, H Function C

(1) Contact Y1 :- Control for functions B, C, Ac, Bw.- Partial stop for functions At, Ht.- Function D if Di selected.- Not used for functions A and H.

Functions L, Li

(1) Link A2-Y1 for function L only.

U

R

C

t1 t2

U

R

C

T T

U

C

RT

Tr Ta

U

RTa Tr

U

R

U

R

C

t1 t2T

T T T T T T

U

RT T T T T

U

R

U

C

RT T

U

R

C

T T

5219

26

5219

27

5219

28

R

A2/

LA

1

U

±

±

R

LA

1

U

±

±

A2 Y2

Y2

R

A2 Y1

18A

1

U

Y1(1)

a/c

a/c

(1)

R

A2 Y1

18A

1

U

Characteristics :pages 2/14 and 2/15

Dimensions :page 2/16

2/18

2

Characteristics 2 Zelio Time -industrial timing relays 2

Single or multifunction relays, solid state output,width 22.5 mm

The RE9 range of relays is designed for simple, repetitive applications with short and intensive cycles because their solid state output provides very high electrical durability.Each relay has a single timing range.Each relay has a wide voltage range from 24 to 240 V.The range comprises 9 references with 3 model types:� RE9 TA: function A,� RE9 RA: function C,� RE9 MS: multifunction A, H, L, Li.These products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. This flap can be directly sealed.

Presentation

5608

53

EnvironmentConforming to standards IEC 61812-1, EN 61812-1

Product certifications CSA, GL pending. UL

��������marking Zelio Time timing relays conform to European regulations relating to � marking

Ambient air temperaturearound the device

Storage °C - 40…+ 85

Operation °C - 20…+ 60Permissible relative humidity range

Conforming to IEC 60721-3-3 15…85 % Environmental class 3K3

Vibration resistance Conforming to IEC 60068-2-6, 10 to 55 Hz

a = 0.35 ms

Shock resistance Conforming to IEC 60068-2-27 15 gn - 11 ms

Degree of protection Casing IP 50Terminals IP 20

Degree of pollution Conforming to IEC 60664-1 3

Overvoltage category Conforming to IEC 60664-1 III

Rated insulation voltage Conforming to IEC V 250Conforming to CSA V 300

Test voltage for insulation tests

Dielectric test kV 2.5 Shock wave kV 4.8

Voltage limits Power supply circuit 0.85…1.1 Uc

Frequency limits Power supply circuit Hz 50/60 ± 5 %

Disconnection value Power supply circuit > 0.1 Uc

Mounting positionwithout derating

In relation to normal vertical mounting plane

Any position

CablingMaximum c.s.a.

Flexible cable without cable end mm2 2 x 2.5

Flexible cable with cable end mm2 2 x 1.5

Tightening torque N.m 0.6…1.1

Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1)Electrostatic discharge Conforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)

Electromagnetic fields Conforming to IEC 61000-4-3 Level 3 (10 V/m)

Fast transients Conforming to IEC 61000-4-4 Level 3 (2 kV)

Shock waves Conforming to IEC 61000-4-5 Level 3 (2 kV)

Radiated and conducted emissions

CISPR11 Group 1 class A

CISPR22 Class A

References : page 2/20

Dimensions :page 2/20

Schemes : page 2/21

2/19

2

Characteristics(continued) 2

Zelio Time -industrial timing relays 2

Single or multifunction relays, solid state output,width 22.5 mm

Timing relay type RE9 TA On-delay

RE9 RAOff-delay

RE9 MSMultifunction

Supply characteristicsSupply voltage V �/� 24…240 � 24…240 �/� 24…240.

See page 2/20

Voltage limits Of the control circuit 0.85…1.1 Un

Frequency Hz 50…60 ± 5 %

Control contact Mechanical only In series Between Y2 and A2 In series

Maximum length of connecting cable

From contact to RE9 m – 20 –

Control input consumption Input Y2 mA – 5 –

Timing characteristicsSetting accuracy < ± 20 %

Repeat accuracy < 1 %

Minimum reset time After the time delay period ms 100

Minimum switching time ms – 40 –

Maximum immunity to microbreaks

During the time delay period ms 100 2 70After the time delay period ms 2 – 2

Temperature drift ≤ 0.1 % per degree centigrade

Switching characteristics (solid state type)Maximum continuous current At ambient temperature: 20 °C A 0.7 (minimum 10 mA)

Maximum overload current VDE 0435 part. 303, 4.8.3/Class II

A 15 for 10 ms

Maximum voltage drop Closed state V 3 (at 0.7 A)

Leakage current Open state mA ≤ 6 ≤ 1 ≤ 6

Maximum dissipated power W 2.5 4 2.5

Derating For temperature > 20 °C mA Without

Electrical durability In millions of operating cycles > 100

References : page 2/20

Dimensions :page 2/20

Schemes : page 2/21

2/20

2

Functions,references,dimensions 2

Zelio Time - industrial timing relays 2

Single or multifunction relays, solid state output, width 22.5 mm

Solid state output� Multifunction or single function� Multivoltage� Screw terminals

Function diagramsFunction A Function C Function H

Delay on energisation

Timing after opening of control contact

Timing on energisation

Function D Function DiSymmetrical flashing, start with output in rest position

Symmetrical flashing, start with output in operating position

References

Functions A C A, H, D, DiVoltages ��or � 24…240 V � – ��(A)

��24…240 V – � ��(H, D, Di)Timing ranges 0.1 s…10 s RE9 TA11MW RE9 RA11MW7 RE9 MS21MW

0.3 s …30 s RE9 TA31MW RE9 RA31MW7 –3 s…300 s RE9 TA21MW RE9 RA21MW7 RE9 MS21MW40 s…60 min RE9 TA51MW RE9 RA51MW7 –

Weight (kg) 0.110 0.110 0.110

DimensionsRail mounting Screw fixing

U

RT

U

C

RT

U

RT

T T T T T T

U

R

U

RT T T T T

5608

54

5608

55

5608

55

89,5

82

78

80

66

78

Characteristics :pages 2/18 and 2/19

Schemes :page 2/21

2/21

2

Schemes 2 Zelio Time - industrial timing relays 2

Single or multifunction relays, solid state output, width 22.5 mm

Terminal blocksRE9 TA RE9 RA RE9 MS

Recommended application schemesRE9 TA

The timing relay is placed in series, with the load whose energisation is to be delayed on one side and switch K on the other side. The mains supply may be a.c. or d.c. and the voltage may be between 24 V and 240 V. See function diagram on page opposite.

RE9 RA

The timing relay is placed in series with the load whose de-energisation is to be delayed. Switch K is connected to terminals Y2 and A2 of the timing relay, and terminal A2 is connected to the mains supply, as indicated in the diagram opposite. The device is operated from an a.c. mains supply whose voltage is between 24 V and 240 V. See function diagram on page opposite.

RE9 MSDelay on energisationFunction A

Timing on energisationFunction H Selection of the timing range

X3-X4 not linked: range 3 s…300 s(factory configuration)

X3-X4 linked: range 0.1 s…10 s

Link to be made between terminals X1 and X4

Symmetrical flasher,start with output in rest positionFunction D

Symmetrical flasher,start with output in operating positionFunction Di

Link to be made between terminals X2 and X4 on one side and between X1 and X2 on the other side

Link to be made between terminals X1 and X4

Note : For supply voltages greater than 30 V, the rated voltage of the load is equal to the supply voltage. For a supply voltage of 24 V, the voltage drop within the RE9 relay must be taken into account (about 3 V); a coil with a nominal voltage of 21 V must therefore be selected for the load.

A1 L A1 L

Y2 A2

A1 L

X1 X3X2

X4

LA1KRE9-TA

Supply � or �

Load

LA1

K A2Y2

RE9-RA

Supply �

Load

A2L A1A1KX3 X4

RE9-MS

Supply � or �

Load

A2L A1A1KX1 X3 X4

RE9-MS

Supply �

Load

A2L A1A1KX2 X3X1 X4

RE9-MS

Supply �

Load

A2L A1A1KX2 X3 X4

RE9-MS

Supply �

Load

Characteristics :pages 2/18 and 2/19

Dimensions :page 2/20

2/22

2

Characteristics 2 Zelio Time - modular timing relays 2

Relays with relay output, width 17.5 mm

Timing characteristicsRelay type RE11 R���������������� RE11 RME MU

Selectable timing rangesby selector switch on front panel

s 0.1…1 0.1…11…10 1…10

min 0.1…1 0.1…11…10 1…10

h 0.1…1 0.1…1

1…10 1…1010…100 –

Repeat accuracy(with constant parameters)

Conforming to IEC 61812-1 ± 0.5 %

Drift Temperature ± 0.05 % / °C

Voltage ± 0.2 % / VSetting accuracy at full scale

Conforming to IEC 61812-1 ± 10 % at 25 °C

Minimum duration of control pulse

Typical ms 30Typical with load in parallel ms 100

Maximum reset time by de-energisation

Typical ms 100

Immunity to microbreaks Typical ms > 10

Supply characteristicsRelay type RE11 R���������������� RE11 R���� JU

Supply voltage V �/��12…240��24/� 24…240 depending on version

�/� 12 V

Frequency Hz 50/60

Operating range 85…110 % of Un 90…120 % of UnOn-load factor 100 %Maximum power consumption

Depending on model

�/� 12 V VA/W – 0.4

� 24 V W 0.6 –� 240 V W 1.5 –� 240 V VA 32 –

Output characteristicsRelay type RE11 R���������������� RE11 RME MU

Output type Relay, 1 C/O contact, AgNi (cadmium-free)Breaking capacity ��2000 VA, ��80 W ��1250 VA, ��50 W

Maximum breaking current A ��8, ��8 ��5, ��5

Minimum breaking current mA 10 /� 10 V

Maximum switching voltage V �/��250 (except RE11 RMX MU: � 250 and � 150 )Electrical life 105 operations 8 A 250 V resistive 105 operations 5 A 250 V resistive

Mechanical life 5 x 106 operationsDielectric strength Conforming to IEC 61812-1 kV 2.5/1min/1 mA/50 Hz

Impulse voltage Conforming to IEC 60664-1, IEC 61812-1

kV 5, wave: 1.2/50 µs

Display characteristicsState indication by 1 LED Green Operating status indication

Pulsing: relay energised, no timing in progress (except functions Di-D and Li-L)Flashing: timing in progressOn steady: relay energised, no timing in progress

Input characteristicsInput type Volt-free contact (no potential)

Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer

References :pages 2/23 and 2/24

Dimensions :pages 2/24 and 2/26

Schemes :pages 2/25 and 2/27

2/23

2

Characteristics (continued) 2 Zelio Time - modular timing relays 2

Relays with relay output, width 17.5 mm

General characteristicsConforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC

(� marking) + EMC directive (89/336/EEC + IEC 60669-2-3)

Approvals cULus, CSA,GL except RE11 RMX MU and RE11 RME MU

Ambient air temperature around the device

Storage °C - 30…+ 60

Operation °C - 20…+ 60

Creepage distance and clearance

Conforming to IEC 60664-1 kV 4 kV/3

Degree of protectionconforming to IEC 60529

Terminal block IP 20Housing IP 40

Front panel IP 50

Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 HzA = 0.35 mm

Relative humiditywithout condensation

Conforming to IEC 60068-2-3 93 %

Electromagnetic compatibility Immunity to electrostatic discharge,conforming to IEC 61000-4-2

Level III (Air 8 kV/Contact 6 kV)

Immunity to electromagnetic fields,conforming to ENV 50140/204 (IEC 61000-4-3)

Level III (10 V/m: 80 MHz…1 GHz)

Immunity to fast transients in bursts,conforming to IEC 61000-4-4

Level III (direct 2 kV / capacitive connecting clip 1 kV)

Immunity to surges on the power supplies,conforming to IEC 61000-4-5

Level III (common mode 2 kV / differential mode 1 kV)

Immunity to radio frequency interference in common mode,conforming to ENV 50141 (IEC 61000-4-6)

Level III (10 V rms: 0.15…80 MHz)

Immunity to voltage dips and breaks,conforming to IEC 61000-4-11

30 % / 10 ms60 % / 100 ms95 % / 5 s

Radiated and mains conducted disturbance,conforming to EN 55022(EN 55011 Group 1)

Class B

Fixing Symmetrical mounting rail (EN 50022)

mm 35

Clamping capacity Without cable end mm2 2 x 2.5 and 1 x 4With cable end mm2 2 x 1.5

Spring terminals, 2 terminals per connection point

Flexible cable mm2 1.5

Solid cable mm2 2.5

Housing material Self-extinguishing

References :pages 2/23 and 2/24

Dimensions :pages 2/24 and 2/26

Schemes :pages 2/25 and 2/27

2/24

2

Functions,references,dimensions,schemes 2

Zelio Time - modular timing relays 2

Relays with relay output,width 17.5 mm

Output 1 C/O contact� Dual function or single function� Multi-range (7 selectable ranges)� Multivoltage� 1 relay output: 8 A� Screw terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option

Function diagramsFunction A Function AtDelay on energisation

Delay on energisation with memory

T = t1 + t2 + …

Function H Function HtTiming on energisation

Timing on energisation with memory

T = t1 + t2 + …

References

Functions Dual function Dual functionA - At H - Ht

Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

Voltages �/ � 12 V – –��24 V / � 24…240 V RE11 RA MU RE11 RH MU

Nominal output current 8 A 8 A

Connection Screw terminals � �

Weight (kg) 0.060 0.060

Dimensions and connection schemesDimensions

U

RT

U

R

C

t1 t2

U

RT

U

R

C

t1 t2T

5219

29

5219

29

5,5

72

17,9

81

Characteristics :pages 2/22 and 2/23

Schemes :page 2/27

2/25

2

22

Function L Function LiAsymmetrical flashing, start with output in rest position

Asymmetrical flashing, start with output in operating position

Function B Function CTiming on impulse, one shot

Timing after opening of control contact

Dual function Dual function Single function Single functionL - Li L - Li B C1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

– RE11 RL JU – –RE11 RL MU – RE11 RB MU RE11 RC MU8 A 8 A 8 A 8 A� � � �

0.060 0.060 0.060 0.060

Connection schemesFunctions A and At

Functions H and Ht

Functions L and Li

Functions B and C

(1) Link A1-Y1 for function L only.

Tr Ta

U

RTa Tr

U

R

U

R

C

T T

U

C

RT

5219

30

5219

30

521

929

521

929

A2 Y1

A1

U

+

16

15R

18

A2 Y1

A1

U

+

16

15R

18

A2 Y1

A1

U

+

16

15R

18

(1)

A2 Y1

A1

U

+

16

15R

18

Characteristics :pages 2/22 and 2/23

Dimensions :page 2/26

2/26

2

Functions,references,dimensions,scheme 2

Zelio Time - modular timing relays 2

Relays with relay output, width 17.5 mm

Output 1 C/O contact� Multifunction� Multi-range (6 or 7 selectable ranges)� Multivoltage� 1 relay output: 5 or 8 A� Screw or spring terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option

Function diagramsFunction A Function At Function B

Delay on energisation

Delay on energisation with memory

T = t1 + t2 + …

Timing on impulse, one shot

Function C Function H Function HtTiming after opening of control contact

Timing on energisation

Timing on energisation with memory

T = t1 + t2 + …

Function D Function Di Function AcSymmetrical flashing, start with output in rest position

Symmetrical flashing, start with output in operating position

Timing after closing and opening of control contact

References

Functions Multifunction MultifunctionA - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di - Ac - Bw

Timing ranges 6 or 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hVoltages �/��12 V – –

��24 V / ��24…240 V RE11 RM MU –�/��12…240 V – RE11 RM MW

Nominal output current 8 A 8 A

Connection Screw terminals � �

Spring terminals – –Weight (kg) 0.060 0.060

Dimensions and connection schemeDimensions

RE11 RM���� MU, RE11 RM MW, RE11 RM JU RE11 RM MWS

U

RT

U

R

C

t1 t2

U

R

C

T T

U

C

RT

U

RT

U

R

C

t1 t2T

T T T T T T

U

RT T T T T

U

R

U

C

RT T

5219

31

5219

31

5,5

72

17,9

81

5,5

72

17,9

81

Characteristics :pages 2/22 and 2/23

Schemes :page 2/25

2/27

2

22

Function Bw Function Ad Function Ah Function N Function OPulse output (width adjustable)

Timing on closing of control contact

Flashing single cycle by operation of control contact

"Safe-guard"

"Delayed safe-guard"

Function P Function Pt Function T Function Tt Function WDelayed fixed-length pulse

P = 500 ms

Impulse counter (on-delay)

T = t1 + t2 + …P = 500 ms

Bistable relay

Timed impulse relay

On-delay after opening of control contact

Multifunction Multifunction Multifunction MultifunctionA - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di Ad - Ah - N - O - P - Pt - T - Tt - W1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

– RE11 RM JU – –

– – RE11 RME MU RE11 RMX MURE11 RM MWS – – –8 A 8 A 5 A 8 A

– � � �

� – – –

0.060 0.060 0.060 0.060

Connection scheme

(1) Contact Y1 :- Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.- Partial stop for functions At, Ht and Pt.- Function D if Di selected.- Not used for functions A, H and P.

U

R

C

T T

U

R

C

T T

U

R

C

TT T T T

U

C

R T T T

U

C

Rt<T

U

RT P

t1 t2 P

U

G

R

U

C

R

U

C

RT t<T T

U

C

R

5219

32

5219

31

5219

31

5219

33

A2 Y1

A1

U

+

16

15R

18

Y1(1)

Characteristics :pages 2/22 and 2/23

Dimensions :page 2/24

2/28

2

Characteristics 2 Zelio Time -industrial timing relays 2

Single, dual or multifunction relays, relay output,width 22.5 mm

Timing characteristicsRepeat accuracy(with constant parameters)

Conforming to IEC 61812-1 ± 0.5 %

Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V

Full scale setting accuracy Conforming to IEC 61812-1 ± 10 % at 25 °C

Minimum duration of control impulse

Typical ms 30Typical under load ms 100

Maximum reset time by de-energisation

Typical ms 100

Immunity timeto microbreaks

Typical ms > 10

Supply characteristicsMultivoltage supply Depending on version, see pages 2/30 to 2/33

Frequency Hz 50/60Operating range 85…110 % Un (85…120 Un for �/��12 V )On-load factor 100 %

Maximum power consumption

Depending on model

� 24 V W 0.6

� 240 V W 1.5� 240 V VA 32

Output characteristicsOutput type C/O contact, AgNi (cadmium-free)

Breaking capacity ��2000 VA, ��80 WMaximum breaking current A �/�� 8Minimum breaking current mA 10 / ��5 V

Maximum switching voltage V �/��250 Electrical durability 105 operations 8 A 250 V resistive Mechanical durability 5 x 106 operations

Dielectric strength Conforming to IEC 61812-1 kV 2.5/1 min/1 mA/50 HzImpulse voltage Conforming to IEC 60064-1,

IEC 61812-1kV 5, wave 1.2/50 µs

Display characteristicsState indication by 2 LEDs Green Operating status indication green LED

Pulsing: relay energised, no timing in progress (except Di-D and Li-L)

Flashing: timing in progress

On steady: relay energised, no timing in progress

Yellow On-delay relay

Input characteristicsInput type Volt-free contact (no potential)

Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer

References :pages 2/30 to 2/33

Dimensions :pages 2/30 to 2/33

Schemes :pages 2/30 to 2/33

2/29

2

Characteristics (continued) 2 Zelio Time -industrial timing relays 2

Single, dual or multifunction relays, relay output, width 22.5 mm

General characteristicsConforming to standards IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC

(� marking) + EMC (89/336/EEC + IEC 669-2-3)

Product certifications c UL us, CSA,GL except RE 88 865 503 and RE 88 865 265

Temperature limits Operation °C - 20…+ 60 Storage °C - 30…+ 60

Creepage distance and clearance

Conforming to IEC 60664-1 kV 4 kV/3

Degree of protectionconforming to IEC 529

Terminal block IP 20

Housing IP 40Front face IP 50 except RE 88 865 265 (IP 30)

Vibration resistance Conforming to IEC 68-2-6 f = 10…55 HzA = 0.35 mm

Relative humiditywithout condensation

Conforming to IEC 68-2-3 93 %

Electromagnetic compatibility

Immunity to electrostatic discharge,conforming to IEC 1000-42

Level III (Air 8 kV/Contact 6 kV)

Immunity to electromagnetic fields, conforming to ENV 50140/204 (IEC 1000-4-3)

Level III (10 V/m: 80 MHz…1 GHz)

Immunity to fast transients in bursts,conforming to IEC 1000-4-4

Level III (direct 2 kV / capacitive connecting clip 1 kV)

Immunity to surges on the power supply, conforming to IEC 1000-4-5

Level III (common mode 2 kV / differential mode 1 kV)

Immunity to radio frequency interference in common mode conforming to ENV 50141 (IEC 1000-4-6)

Level III (10 V rms: 0.15…80 MHz)

Immunity to voltage dips and breaks, conforming to IEC 1000-4-11

30 % / 10 ms

60 % / 100 ms95 % / 5 s

Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)

Class B

Fixing Symmetrical mounting rail (EN 50022)

mm 35

Clamping capacity Without cable end mm2 2 x 2.5

With cable end mm2 2 x 1.5

Spring terminals, 2 terminals per connection point

Flexible cable mm2 1.5Solid cable mm2 2.5

Housing material Self-extinguishing

References :pages 2/30 to 2/33

Dimensions :pages 2/30 to 2/33

Schemes :pages 2/30 to 2/33

2/30

2

Functions, references,dimensions,schemes 2

Zelio Time -industrial timing relays 2

Single, dual or multifunction relays, relay output, width 22.5 mm

Relay outputs, 1 C/O and 2 C/O contacts� Single or dual function� Multi-timing range (7 switchable ranges)� Multivoltage� 1 and 2 relay outputs: 8 A - 250 V (10 A UL)� Screw or spring terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option

Function diagramsFunction B Function C Function Q

Timing on impulse, one shot

Off-delay

Star-delta starting

Function KDelay on de-energisationTrue Off-delay(without auxiliary supply)2 timed contacts

References

Connection Screw terminals � � � �

Spring terminals – – – –Functions Single function Single function Single function Single function

B C Q K

Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

4 ranges – – – 0.6 s - 2.5 s - 20 s - 160 s

Selectable interswitching time – – 20 - 40 - 60 - 80 -100 - 120 - 140 ms

Relay output 1 timed contact 1 timed contact 1 timed contact 2 timed contactsVoltages ��24 V / ��24…240 V RE 88 865 125 RE 88 865 135 RE 88 865 175 RE 88 865 265

�/��12 V – – – –

�/��12…240 V – – – –��230 / 380 V – – RE 88 865 176 –

Weight (kg) 0.090 0.090 0.090 0.090

Dimensions and connection schemesDimensions Connection schemes

All functions except K RE 88 865 3�������� and RE 88 865 215

U

C

R∞ T

U

C

R∞ T

TR

U

Ti

TR1/R2

U

5611

72

5611

72

5611

72

5611

76

32

3,5

95

5

57 78

63 22,5

A1 15 Y1

18 16 A2

U

A1R1 R215

A21816

25/21

28/2426/22

Y1

+

Characteristics :pages 2/28 and 2/29

2/31

2

22

Function A Function H Function LDelay on energisation

Timing on energisation

Asymmetrical recyclerStart after pause

Function At Function Ht Function LiTiming on energisation with memory

Delay on energisation with memory

Asymmetrical recyclerPulse start

� � � �

– – – –Dual function Dual function Dual function Dual function

A - At A - At H - Ht Li - L

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

– – – –

– – – –

1 timed contact 2 timed contacts 1 timed contact 1 timed contactRE 88 865 115 RE 88 865 215 RE 88 865 145 RE 88 865 155– – – –

– – –– – – –0.090 0.090 0.090 0.090

Function KRE 88 865 265

All functions except L and LiRE 88 865 1������������

Functions L and LiRE 88 865 155

Function QRE 88 865 17����

(1) Link A1-Y1 for function L only.

U

RT T

R

U

T1R

T2

U

U

C

Rt1 t2

T = t1+t2t1

R

C

U

t2T = t1+t2

T1R

U

T2

5611

72

5611

76

5611

72

5611

73

U

A1

A2

R1 R2

15

1816

25

2826

+U

A1R

15

A21816

Y1

+U

A1R

15

(1)

A21516

Y1

+

U

A1R

15

A21828

+

Characteristics :pages 2/28 and 2/29

2/32

2

Functions,references,scheme 2

Zelio Time -industrial timing relays 2

Single, dual or multifunction relays, relay output, width 22.5 mm

Relay outputs, 1 C/O and 2 C/O contacts� Multifunction� Multi-timing range (7 switchable ranges)� Multivoltage� 1 and 2 relay outputs: 8 A - 250 V (10 A UL) of which 1 convertible to instantaneous � Screw or spring terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option

Function diagramsFunction A Function At Function B

Delay on energisation

Timing on energisation with memory

Timing on impulse, one shot

Function C Function H Function HtOff-delay

Timing on energisation

Delay on energisation with memory

Function Di Function D Function AcFlashing relayPulse start

Flashing relayStart after pause

Timing after closing/opening of control contact

Function BwPulse output (adjustable)

References

Connection Screw terminals � � –Spring terminals – – �

Functions Multifunction Multifunction MultifunctionA - At - B - C - H - Ht - Di - D - Ac - Bw

A - At - B - C - H - Ht - Di - D - Ac - Bw

A - At - B - C - H - Ht - Di - D - Ac - Bw

Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hRelay output 1 timed contact 2 timed contacts, 1 of which

convertible to instantaneous1 timed contact

Voltages ��24 V / ��24…240 V RE 88 865 105 RE 88 865 305 –�/��12 V RE 88 865 100 RE 88 865 300 –

�/��12…240 V RE 88 865 103 RE 88 865 303 RE 88 865 503Weight (kg) 0.090 0.090 0.090

U

C

R∞ T

U

C

Rt1 t2

T = t1+t2

U

C

R∞ T

TR

U

Ti TR

U

t1R

C

U

t2T = t1+t2

U

RT T T

R1/R2

UU

C

RT T

U

C

RT T

5611

71

5611

75

5611

74

Characteristics :pages 2/28 and 2/29

2/33

2

22

Function Ad Function Ah Function N Function O Function PDelay on energisation by switch

Flashing single cycle by switch

"Safe-guard"

"Delayed safe-guard"

Delayed fixed-length pulse

Function Pt Function TI Function Tt Function WImpulse counter (on-delay)

Impulse relay

Timed impulse relay

Timing after pulse on control contact

Connection scheme

� �

– –Multifunction Multifunction

Ad - Ah - N - O - P - Pt - Tl - Tt - W Ad - Ah - N - O - P - Pt - Tl - Tt - W

1 timed contact 2 timed contacts

RE 88 865 185 RE 88 865 385– –

– –0.090 0.090

U

C

RTT

U

C

RTTTT

U

C

RTT

U

C

RTT T

U

RT P

P = 500 ms

U

C

RP

T = t1 + t2P = 500 ms

t2t1

U

C

R

U

C

RT t

U

C

RT T

A2 Y1

A1

U

+

16

15R

18

5611

71

5611

71

Characteristics :pages 2/28 and 2/29

2/34

2

Characteristics 2 Zelio Time - industrial timing relays 2

Single or multifunction relays, relay output, width 22.5 mm

The RE7 range of relays, with only 23 references, covers all timing applications.

These relays offer multi-range timing from 50 ms to 300 h.

They are multivoltage.

Three models combine several different functions: multifunction relays.

These products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. This flap can be directly sealed.

Presentation

5608

72

References :pages 2/36 to 2/39

EnvironmentConforming to standards IEC 61812-1, EN 61812-1Product certifications CSA, GL pending, UL���� marking Zelio Time timing relays conform to European regulations relating to � marking

Ambient air temperaturearound the device

Storage °C - 40…+ 85Operation °C - 20…+ 60

Permissible relative humidity range

Conforming to IEC 60721-3-3 15…85 % Environmental class 3K3

Vibration resistance Conforming to IEC 60068-2-6, 10 to 55 Hz

a = 0.35 ms

Shock resistance Conforming to IEC 60068-2-27 15 gn - 11 ms

Degree of protection Casing IP 50Terminals IP 20

Degree of pollution Conforming to IEC 60664-1 3

Overvoltage category Conforming to IEC 60664-1 IIIRated insulation voltageBetween contact circuit and power supply or between contact circuit and control inputs

Conforming to IEC V 250Conforming to CSA V 300

Test voltage for insulation tests

Dielectric test kV 2.5

Shock wave kV 4.8Voltage limits Power supply circuit 0.85…1.1 UcFrequency limits Power supply circuit Hz 50/60 ± 5 %

Disconnection value Power supply circuit > 0.1 UcMounting positionwithout derating

In relation to normal vertical mounting plane

Any position

CablingMaximum c.s.a.

Flexible cable without cable end mm2 2 x 2.5 Flexible cable with cable end mm2 2 x 1.5

Tightening torque N.m 0.6…1.1

Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1)Electrostatic discharge Conforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)

Electromagnetic fields Conforming to IEC 61000-4-3 Level 3 (10 V/m)Fast transients Conforming to IEC 61000-4-4 Level 3 (2 kV)Shock waves Conforming to IEC 61000-4-5 Level 3 (2 kV)

Radiated and conducted emissions

CISPR11 Group 1 class ACISPR22 Class A

Consumption� 50/60 Hz �

Average consumption 24 V 48 V 110 V 240 V 24 V 48 V 110 V 240 VRE7-��11BU VA 0.7 1.6 1.8 8.5 W 0.5 1.2 – –

RE7-��12BU and RE7-��13BU VA 1.2 2 2.8 12.5 W 0.8 1.6 – –RE7-����MW (1) VA 2 2.5 3.2 6 W 2 1 3.2 2(1) RE7-RB��MW: current peak on energisation = 1 A / 30 ms.

2/35

2

Characteristics (continued) 2 Zelio Time - industrial timing relays 2

Single or multifunction relays, relay output, width 22.5 mm

Timing characteristicsSetting accuracy As % of the full-scale value ± 10 %Repeat accuracy ± 0.2 %Influence of voltage In the voltage range, 0.85…1.1 Un < 0.2 %

Influence of temperature < 0.07 %/°CImmunity to microbreaks ms 3Minimum control pulse ms 20 (except RE7-RB1�MW: 1 s)

Reset time ms 50

Output circuit characteristicsMaximum switching voltage V � 250

Mechanical durability In millions of operating cycles 20Current limit Ith A 8 (except RE7-RB��MW: 5 A)Rated operational limits at 70 °CConforming to IEC 60947-5-1/1991and VDE 0660

24 V 115 V 250 V

AC-15 A 3 3 3DC-13 A 2 0.2 0.1

Minimum switching capacity 12 V/10 mA

Contact material 90/10 nickel silver(except RE7-RB��MU: gold flashed silver alloy)

Remote control input characteristicsMaximum voltage Applicable to inputs

Y1Z2, X1Z2, X2Z2V 60

Signal delivered by control inputs Y1Z2, X1Z2, X2Z2

No galvanic insulation between these inputs and the supply

Switching current mA < 1Maximum distance m 50

Compatibility 3/4-wire PNP and NPN Telemecanique sensors or other sensors without an internal load

Potentiometer for connection between terminals Z1Z2, Z3Z2

Type Linear at ± 20 %Resistance kΩ 47 ± 20 %

Power W 0.2Maximum distance m 25 by shielded cable: shielding linked to terminal Z2

References :pages 2/36 to 2/39

a.c. load d.c. loadCurve 1 Curve 2 Load limit curveElectrical durability of contacts on resistive load in millions of operating cycles

Reduction factor k for inductive loads (applies to values taken from durability curve 1)

A RE7-RB��������MW A RE7-RB��������MW1 L/R = 20 ms2 L/R with load protection diode3 Resistive load

Example:An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3.For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.

For cos ϕ = 0.3: k = 0.6The electrical durability therefore becomes:1.5 106 operating cycles x 0.6 = 900 000 operating cycles.

10

1

0,1

0,010 1 2 3 4 5 6 7 8

A

Current broken in A

M

illio

ns o

f ope

ratin

g cy

cles

Power factor on breaking (cos ϕ)

1

0,6

0,5

0,9

0,8

0,7

0,4

0,31 0,8 0,6 0,5 0,4 0,3 0,2

R

educ

tion

fact

or k 300

40

30

200

100

50

20

100,1 0,2 0,5 1 2 5 2010

1

2

3

A

Current in A

Vol

tage

in V

RE7

K

+

2/36

2

Functions,references,dimensions,schemes 2

Zelio Time - industrial timing relays 2

Single or multifunction relays, relay output, width 22.5 mm

Output 1 C/O contactMultiple timing ranges

Function diagramsFunction A Function At Function Aw

Delay on energisation

Delay on energisation with memory

Off-delay on energisation or on opening of control contact

T = t1 + t2 + …

Function Ac Function AkTiming after closing and opening of control contact

Asymmetrical On-delay and Off-delay with external control

T = t1 + t2 + …T = t’1 + t’2 + …

Ta = t1 + t2 + …Tr = t’1 + t’2 + …

References

Functions A A, Aw, At Ac Ak

Timing ranges 0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

Voltages ��or � 24 V � � � �

��110…240 V � � � �

� or � 42…48 V – � � �

��or � 24…240 V – – – –References RE7 TL11BU RE7 TM11BU RE7 MA11BU RE7 MV11BU

Weight (kg) 0.150 0.150 0.150 0.150

Dimensions and connection schemesDimensions

Rail mounting Screw fixing

U

RT

U

R

C

t1 t2

U

R

C

T T

U

C

t1

G

Rt'1t2 t'2

U

C

t1

G

Rt'1t2 t'2

5608

73

5608

73

5608

74

5608

74

89,5

80

82

22,5

78

66

78

Ø4

Characteristics :pages 2/34 and 2/35

Schemes :pages 2/40 and 2/41

2/37

2

22

Function K Function C Function H Function Ht Function WDelay on de-energisation (without auxiliary supply)

Timing after openingof control contact

Timing on energisation

Timing on energisation with memory

On-delay after opening of control contact

T + t1 + t2 + …

Function D Function Di Function L Function Li Function LtSymmetrical flashing, start with output in rest position

Symmetrical flashing, start with output in operating position

Asymmetrical flashing, start with output in rest position

Asymmetrical flashing, start with output in operating position

Asymmetrical flashing with partial stop of timing

Tr = t1 + t2 + …Ta = t’1 + t’2 + …

(1) If the device has been stored, de-energised, for more than a month, it must be energised for about 15 seconds in order to activate it. Subsequently, it only takes 1 second to start the time delay. � If this time is not complied with, the relay remains energised indefinitely.

(2) 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

K C H Ht, W D L, Li, Lt A, C, H, W, D, Di

0.05 s…10 min 7 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

– � � � � � �

– � � � � � �

– � – � – � �

� – – – – – –RE7 RB11MW RE7 RA11BU

RE7 RM11BU low level contact

RE7 PE11BU RE7 PM11BU RE7 CL11BU RE7 CV11BU RE7 ML11BU

0.150 0.150 0.150 0.150 0.150 0.150 0.150

Connection schemesRE7 TL11BU

RE7 RB11MW

RE7 PE11BU

RE7 TM11BU,RE7 RA11BURE7 RM11BU,RE7 PM11BU

RE7 MA11BURE7 MV11BU

RE7 CL11BU

RE7 CV11BU

U

RT

> 1 s (1)

U

C

RT

U

RT

U

R

C

t1 t2T T

U

C

R

T T T T T T

U

R

U

R1/R2

T T T T T

R2 inst.(2)

Tr Ta

U

RTa Tr

U

R

R

G

t1 t’2t2 t’1

U

5608

75

5608

75

5608

76

5608

76

5608

77

5608

77

5609

08

A1 15 B1

18 16 A2

1815B

1

A1

A2

16

A1 15

18 16 A2

1815A

1A

2

16

A1 15 B1

18 16 A2

1815B

1

A1

A2

16

A1 15 B1Z1 B2

Y1X1 Z218 16 A2

1815B

1

A1

B2

A2

16

A1 15 B1Z1 B2

Y1X1 Z218 16 A2

1815B

1

A1

B2

A2

16

A1 15 B1

18 16 A2

1815B

1

A1

A2

16

A1 15 B1Z3Z1 B2

X2X1 Z218 16 A2

1815B

1

A1

B2

A2

16

Characteristics :pages 2/34 and 2/35

Dimensions :page 2/36

Schemes :pages 2/40 and 2/41

2/38

2

Functions,references,dimensions,schemes 2

Zelio Time - industrial timing relays 2

Single or multifunction relays, relay output, width 22.5 mm

Output 2 C/O contactsMultiple timing ranges

Function diagramsFunction A Function Ac Function C

Delay on energisation

Timing after closing and opening of control contact

Timing after opening of control contact

Function KDelay on de-energisation (without auxiliary supply)

(1) 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).(2) If the device has been stored, de-energised, for more than a month, it must be energised for

about 15 seconds in order to activate it. Subsequently, it only takes 1 second to start the time delay. � If this time is not complied with, the relay remains energised indefinitely.

References

Functions A Ac C KTiming ranges 0.05 s…300 h

10 ranges0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…10 min 7 ranges

Voltages ��or � 24 V � � � –

��110…240 V � � � –� or � 42…48 V � � � –��or � 24…240 V – – – �

References RE7 TP13BU RE7 MA13BUsymmetrical

RE7 RL13BUlow level contact

RE7 RB13MW

Weight (kg) 0.150 0.150 0.150 0.150

Dimensions and connection schemesDimensions

Rail mounting Screw fixing

U

R1/R2

T

R2 inst.(1)

U

C

R1/R2

T T

R2inst.(1)

U

R1/R2

C

T

R2 inst.(1)

U

R1

R2T

> 1 s (2)

5609

02

5609

03

5609

04

5609

04

89,5

80

82

22,5

78

66

78

Ø4

Characteristics :pages 2/34 and 2/35

Schemes :pages 2/40 and 2/41

2/39

2

22

Function D Function Di Function HSymmetrical flashing, start with output in rest position

Symmetrical flashing, start with output in operating position

Timing on energisation

Function Qg Function Qt Function WStar-delta timing Star-delta timing On-delay after

opening of control contact

(1) 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

H W D Qt Qg A, C, H, W, D, Di, Qg, Qt0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

0.05 s…300 h 10 ranges

� � � � � � –� � � � � � –� � � � � � –

– – – – – – �

RE7 PP13BU RE7 PD13BU RE7 CP13BU RE7 YA12BU RE7 YR12BU RE7 MY13BU RE7 MY13MW

0.150 0.150 0.150 0.150 0.150 0.150 0.150

Connection schemesRE7 TP13BU

RE7 RB13MW

RE7 YA

RE7 RL13BU, RE7 MA13BURE7 PD13BU

RE7 PP13BURE7 CP13BU

RE7 YR RE7 MY13BU RE7 MY13MW

U

R1/R2

T T T T T T

R2 inst. (1)

U

R1/R2

T T T T T

R2 inst. (1)

U

R1/R2

T

R2 inst. (1)

T T50 ms

U

R1

R2

U

R1

R2T T

50 ms

U

C

R1/R2

T

R2 inst. (1)

5609

05

5609

05

5609

06

5609

07

5609

07

5609

08

5609

08

A1 15 B125 (21)Z1 B2

28 (24) Z218

26 (22)16 A2

1815B

1

A1

B2

A2

16 2825 (2

1)

26

(24)

(22)

A1 1525Z1

26 Z22818 16 A2

1815A

1A

2

16 2825

26

A1 15 B125 B2

28 26 Z218 16 A2

1815B

1

A1

B2

A2

16 2825

26

A1 15 B125 (21)Y1 B2

26 (22)28 (24) Z218 16 A2

1815B

1

A1

B2

A2

16 2825

26 (24)

(21)

(22)

A1 15 B125 (21)Z1 B2

26 (22)28 (24) Z218 16 A2

1815B

1

A1

B2

A2

16 2825

26 (24)

(21)

(22)

B11717

A1B2

28 26 Z218 16 A2

18

B1

A1

B2

A2

16 28

1726

A1 15 B125 (21)Z1 Y1

26 (22)28 (24) Z218 16 A2

1815B

1

A1

A2

16 28 (24)

25 (21)

26 (22)

A1 15 Y125 (21)Z1 X1

26 (22)28 (24) Z218 16 A2

1815A

1A

2

16 2825

26 (24)

(21)

(22)

Characteristics :pages 2/34 and 2/35

Dimensions :page 2/38

Schemes :pages 2/40 and 2/41

2/40

2

Schemes 2 Zelio Time - industrial timing relays 2

Single or multifunction relays, relay output, width 22.5 mm

Recommended application schemesRE7 TL, TM, TP, CL, CP, ML, MY

Start on energisation

RE7 TM, MA, MV, RM, RL, PM, PD, ML, MYStart by external control

RE7 TM, PM, ML, MY

External control of partial stop

RE7 MA, MV, RA, RM

Start by external control

RE7 RBStart on de-energisation

RE7 RAStart by external control

RE7 PPStart on energisation

RE7 PEStart on energisation

RE7 CVSelection of starting phase

RE7 TM, TP, MA, RA, RM, PP, PM, ML, MYConnection of potentiometer

RE7 MV

Connection of potentiometers to asymmetrical timing relays

RE7 CV

Connection of potentiometers

Connection precautions

No galvanic isolation between supply terminals A1, A2, B1, B2 and control inputs X1, Y1, Z1, Z2.

(1)� 110…240 V except RE7 MY13MW :���24…240 V(2)�� 12…48 V (3)�� 24 V(4) Adjustment of the On-delay period(5) Adjustment of the Off-delay period(6) Start during the On-delay period : X2, Z2 linked. Start during the Off-delay period : X2, Z2 not linked(7) Off-delay adjustment (tr) (contact 15/16 closed)(8) On-delay adjustment (ta) (contact 15/18 closed)

B1 A1B2

A2(1)

(2)

(3) B1 A1B2

A2

Y1

Z2(1)

(2)

(3)

B1 A1B2

A2

X1

Z2(1)

(2)

(3) B1 A1B2

A2

X1

Z2(1)

(2)

(3)

A1

A2A1

A2

Y1 B2

A2

Y1

+

B1

A2

Y1

+

B1 A1B2

A2

(1)

(2)

(3) B1 B3B2

A2

(1)

(3) B1 A1B2

A2

X2

Z2(6)(1

)(2

)

(3)

Z1Z2

A2Z1Z3 (4) (5)

Z2A2

Z1Z3 (7) (8)

Z2A2A2 Z2

Sup

ply

X1 or Y1 or Z1

Characteristics :pages 2/34 and 2/35

References :pages 2/36 to 2/39

2/41

2

Schemes (continued) 2 Zelio Time - industrial timing relays 2

Single or multifunction relays, relay output, width 22.5 mm

Recommended application schemes (continued)

Power schemeRE7 YA12BU

Control schemesStar-delta function with double On-delay timing Qt

Power schemeRE7 YR12BU

Control schemesStar-delta function with contact for switching to star connection Q

No galvanic isolation between supply terminals A1, A2, B1, B2 and supply terminal Z2.This terminal must therefore never be used (factory setting).Control of several relays with a single external control contact Connection of a Telemecanique 3-wire NPN or PNP sensor

It is advisable to follow the recommended wiring schemes detailed above and on previous pages. However, the connections below are possible if the restrictions given are taken into account.Connection of an external control contact without using terminal Z2: Connection of a Telemecanique 3-wire NPN or PNP sensor without using

terminal Z2:- possible on all RE7 relays with external control option except RE7 RA11BU,- d.c. supply only.

- only possible on relay RE7����BU,- d.c. supply only.

V2

W2

U2

W1

V1

U1

F2

K2

12

34

56

K1

12

34

56

M1

K3

12

34

56

L1 L2 L3

12

34

56

3K1

A1

A2

96

F2

1516

K1T

2122

K3

2122

1314

S1

S2

K1T

A1

A2

1314 K1

K2

A1

A2

K3

A1

A2

2528

K1T

2122

K1

1413

K2

A1 15 B125 B2

28 26 Z218 16 A2

1815B

1

A1

B2

A2

16 2825

26

Y N Δ95

F3 Terminal block

K1T = relay RE7 YA

V2

W2

U2

W1

V1

U1

F2

K2

12

34

56

K1

12

34

56

M1

K3

12

34

56

L1 L2 L3

12

34

56

3 K1

A1

A2

9596

F2

2122

K3

F3

2122

1314

S1

S2

K1T

A1

A2

K3

A1

A2

K2

A1

A2

1413

5354

K2

2817

2122

K1

1817

K1T K2

1413

K1

B11717

A1B2

28 26 Z218 16 A2

18

B1

A1

B2

A2

16 28

1726

Y NΔ

Terminal block

K1T = relay RE7 YR

Z2A2Z2A2 Z2A2

Sup

ply

A1,B1 or B12Y1 or X1

A1,B1 or B12Y1 or X1

A1,B1 or B12Y1 or X1

BNBK NPN

PNPBU

+

Z2A2

Sup

ply

A1,B1 or B12Y1 or X1

+

Z2A2

A1,B1 or B12Y1 or X1

+

Z2A2

A1,B1 or B12Y1 or X1

BNBK NPNBU

Y1

+

B1B2

Z2A2

24or48 V

BNBK PNPBU

Y1

+

B1B2

Z2A2

24or48 V

Characteristics :pages 2/34 and 2/35

References :pages 2/36 to 2/39

2/42

2

Characteristics 2 Zelio Time - industrial timing relays 2

Optimum single-function relays, relay output, width 22.5 mm

The RE8 range of relays is designed for simple and repetitive applications, providing basic functions.

Each relay comprises:- a single timing range,- a C/O output relay.

These products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. This flap can be directly sealed.

Presentation

5609

53

EnvironmentConforming to standards IEC 61812-1. EN 61812-1

Product certifications CSA, GL pending. UL��������marking Zelio Time timing relays conform to European regulations relating to � markingAmbient air temperaturearound the device

Storage °C - 40…+ 85

Operation °C - 20…+ 60Permissible relative humidity range

Conforming to IEC 60721-3-3 15…85 % Environmental class 3K3

Vibration resistance Conforming to IEC 60068-2-6, 10 to 55 Hz

a = 0.35 ms

Shock resistance Conforming to IEC 60068-2-27 15 gn - 11 msDegree of protection Casing IP 50

Terminals IP 20Degree of pollution Conforming to IEC 60664-1 3Overvoltage category Conforming to IEC 60664-1 III

Rated insulation voltage Conforming to IEC V 250Conforming to CSA V 300

Test voltage for insulation tests

Dielectric test kV 2.5

Shock wave kV 4.8Voltage limits Power supply circuit 0.9…1.1 UcFrequency limits Power supply circuit Hz 50/60 ± 5 %

Disconnection value Power supply circuit > 0.1 UcMounting positionwithout derating

In relation to normal vertical mounting plane

Any position

Connectionmaximum c.s.a.

Flexible cable without cable end mm2 2 x 2.5Flexible cable with cable end mm2 2 x 1.5

Tightening torque N.m 0.6…1.1

Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1)Electrostatic discharge Conforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)

Electromagnetic fields Conforming to IEC 61000-4-3 Level 3 (10 V/m)Fast transients Conforming to IEC 61000-4-4 Level 3 (2 kV)Shock waves Conforming to IEC 61000-4-5 Level 3 (2 kV)

Radiated and conducted emissions

CISPR11 Group 1 class ACISPR22 Class A

ConsumptionConsumption � �

24 V 110 V 240 V 380 V 415 V 24 VRE8-TA, RA, CL, PE, PU, PT VA 0.7 1.8 8.5 – – W 0.5

RE8-YG, RB VA 0.9 2.5 13 – – W 0.5RE8-YA VA 0.9 2.5 13 8 9 W 0.7

References :pages 2/44 to 2/47

Dimensions :pages 2/44 and 2/46

Schemes :page 2/45

2/43

2

Characteristics (continued) 2 Zelio Time - industrial timing relays 2

Optimum single-function relays, relay output, width 22.5 mm

Timing characteristicsSetting accuracy As % of the full-scale value ± 20 %Repeat accuracy < 1 %Influence of voltage In the voltage range, 0.9…1.1 Un < 2.5 %

Influence of temperature < 0.2 %/°CImmunity to microbreaks ms 3Minimum control pulse ms 26 (except RE8-YG: 60)

Reset time ms 50

Output circuit characteristicsMaximum switching voltage V � 250

Mechanical durability In millions of operating cycles 20Current limit Ith A 8Rated operational limits at 70 °CConforming to IEC 60947-5-1/1991and VDE 0660

24 V 115 V 250 V

AC-15 A 3 3 3DC-13 A 2 0.2 0.1

Minimum switching capacity 12 V/10 mA

Contact material 90/10 nickel silver

Remote control input characteristicsSignal delivered by control input Y1

No galvanic insulation between this input and the supply

No-load voltage Supply voltage

Switching current mA < 10Maximum distance m 50Compatibility 2-wire sensors � with leakage current < 1 mA

References :pages 2/44 to 2/47

Dimensions :pages 2/44 and 2/46

Schemes :page 2/45

a.c. load d.c. loadCurve 1 Curve 2 Load limit curveElectrical durability of contacts on resistive load in millions of operating cycles

Reduction factor k for inductive loads (applies to values taken from durability curve 1)

A RE8-RB��BUTQ A RE8-RB��BUTQ1 L/R = 20 ms2 L/R with load protection diode3 Resistive load

Example:

An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3.For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.

For cos ϕ = 0.3: k = 0.6The electrical durability therefore becomes:1.5 106

operating cycles x 0.6 = 900 000 operating cycles.

10

1

0,1

0,010 1 2 3 4 5 6 7 8

A

Current broken in A

Mill

ions

of o

pera

ting

cycl

es 1

0,6

0,5

0,9

0,8

0,7

0,4

0,31 0,8 0,6 0,5 0,4 0,3 0,2

Power factor on breaking (cos ϕ)

Red

uctio

n fa

ctor

k 300

40

30

200

100

50

20

100,1 0,2 0,5 1 2 5 2010

1

2

3

A

Current in A

Vol

tage

in V

RE8

K

+

2/44

2

Functions,references,dimensions,schemes 2

Zelio Time - industrial timing relays 2

Single-function relays, optimum, relay output, width 22.5 mm

Output 1 C/O contactSingle timing range

Function diagramsFunction A Function C

Delay on energisation Timing after opening of control contact

Unit references (Sold in packs of 10)

Functions A CVoltages ��or � 24 V � � –

��110…240 V � – �

� 380…415 V – – –Timing ranges 0.05 s…0.5 s – – –

0.1 s…3 s RE8 TA61BUTQ – –

0.1 s…10 s RE8 TA11BUTQ RE8 RA11BTQ RE8 RA11FUTQ 0.3 s…30 s RE8 TA31BUTQ RE8 RA31BTQ RE8 RA31FUTQ3 s…300 s RE8 TA21BUTQ RE8 RA21BTQ RE8 RA21FUTQ20 s…30 min RE8 TA41BUTQ – RE8 RA41FUTQ

Weight (kg) 0.110 0.110 0.110

DimensionsDimensions

Rail mounting Screw fixing

U

RT

U

C

RT

5609

54

5609

54

89,5

80

82

22,5

78

Ø4

66

78

Characteristics :pages 2/42 and 2/43

Schemes :page 2/45

2/45

2

22

Function K Function DDelay on de-energisation (without auxiliary supply)

Symmetrical flashing, start with output in rest position

(1) If the device has been stored, de-energised, for more than a month, it must be energised for about 15 seconds in order to activate it. Subsequently, it only takes 80 ms to start the time delay. � If this time is not complied with, the relay remains energised indefinitely.

K D� �

� �

– –RE8 RB51BUTQ –– –

RE8 RB11BUTQ RE8 CL11BUTQRE8 RB31BUTQ –– –

– –0.110 0.110

SchemesConnection schemes Recommended application schemes

RE8 TA, CL

RE8 RA

RE8 RB

RE8 TA, CL

RE8 RA

Control of several relays with a single external control contact Connection of a ���� 2-wire sensorRE8 RA, RE8 PD

The external control contact C may be an electronic control device, for example a 2-wire sensor. In this case A1-A2 = � 24 V and the control device can only control up to a maximum of 4 relays.

Leakage current (open state) If < 1 mA.

U

RT

> 80 ms (1)

T T T T T T

U

R

5609

54

5609

54

A1 15 B1

18 16 A2

1815B

1

A2

A1

16

A1 15 Y1

18 16 A2

1815A

2A

1

16

A1 15 B1

18 16 A2

1815B

1

A2

A1

16

B1 A2

A1

A1

A2

Y1

start

Y1A2

Y1A2

Y1A2

A1A1 A1C

Y1

+

A1

A2

If

Characteristics :pages 2/42 and 2/43

Dimensions :page 2/44

2/46

2

Functions,references,dimensions,schemes 2

Zelio Time - industrial timing relays 2

Single-function relays, optimum, relay output, width 22.5 mm

Output 1 C/O contactSingle timing range

Function diagramsFunction H Function W

Timing on energisation

On-delay after opening of control contact

Unit references (Sold in packs of 10)

Functions H WVoltages ��or � 24 V � � –

��110…240 V � – �

� 380…415 V – – –Timing ranges 0.05 s…0.5 s – – –

0.1 s…3 s – – –0.1 s…10 s RE8 PE11BUTQ RE8 PD11BTQ RE8 PD11FUTQ 0.3 s…30 s RE8 PE31BUTQ RE8 PD31BTQ RE8 PD31FUTQ3 s…300 s RE8 PE21BUTQ RE8 PD21BTQ RE8 PD21FUTQ20 s…30 min – – –

Weight (kg) 0.110 0.110 0.110

Dimensions, schemesDimensions

Rail mounting

Screw fixing

Connection schemes (terminal blocks)

RE8 PE

RE8 PD

RE8 PT

RE8 YA

RE8 YG

U

R

T

T

U

C

R

5609

68

5609

68

89,5

80

82

22,5

78

Ø4

66

78

A1 15 B1

18 16 A2

1815

16

B1

A2

A1

A1 15 Y1

18 16 A2

1815A

2A

1

16

A1 15 B1

18 16 A2

1815

16

B1

A2

A1

A1 15 25

28 16 A2

1615A

2A

1

2825

A1 15 B1

18 16 A2

1815B

1A

2A

1

16

Characteristics :pages 2/42 and 2/43

Schemes :page 2/47

2/47

2

22

Function He Function Qc Function QePulse-on de-energisation

Star-delta timing

Star-delta timing

He Qc Qe� � � – –

� � – � –– – – – �

RE8 PT01BUTQ – – – –

– – – – –– RE8 YG11BUTQ – – –– RE8 YG31BUTQ RE8 YA32BTQ RE8 YA32FUTQ RE8 YA32QTQ– RE8 YG21BUTQ – – –– – – – –0.110 0.110 0.110 0.110 0.110

Recommended application schemesPulse-on energisation relays

RE8 PE, RE8 PT RE8 PD

Timing relays for star-delta startersRE8 YG, RE8 YA RE8 YG RE8 YA

(1) K1T: RE8 YG�1��TQ (1) K1T: RE8 YA32��TQ

Note : Correct operation of the star-delta starter associated with the RE8 YG is only possible if the wiring scheme is strictly complied with.

U

R

> 80 ms 80 msT > T T 50 ms

U

R

T 80 ms

U

R1

R2

5609

68

5609

69

5609

69

B1 A2

A1

A1

A2

Y1

+

start

– KM2 – KM3 – KM1

U1

V1

W1

U2

V2

W2

– Q1

L1 L2 L3

– Rth

Y

(1)

Y

A1

A2

A1

A2

A1

A2

A1

A2

16 15

L

(1)

(1)

Y

A1

A2

A1

A2

A1

A2

A1

A2

1516

2528

L

Characteristics :pages 2/42 and 2/43

Dimensions :page 2/46

2/48

2

Characteristics 2 Zelio Time - timing relays 2

Universal plug-in relays, 11-pin,relay output, width 35 mm

Timing characteristicsRepeat accuracy(with constant parameters)

Conforming to IEC 1812-1 ± 0.5 %

Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V

Full scale setting accuracy Conforming to IEC 1812-1 ± 10 % at 25 °C

Minimum duration of control impulse

Typical ms 30Typical under load ms 100

Maximum reset timeby de-energisation

Typical ms 100

Immunity timeto microbreaks

Typical ms > 10

Supply characteristicsMultivoltage supply Depending on version, see pages 2/50 and 2/52

Frequency Hz 50/60Operating range 85…110 % Un (85…120 Un for �/��12 V )On-load factor 100 %

Maximum powerconsumption

Dependingon model

� 24 V W 0.6 � 240 V W 1.5� 240 V VA 32

Output characteristicsOutput type Relay, C/O contacts, AgNi (cadmium free)Breaking capacity � 2000 VA, ��80 WMaximum breaking current A ��8, �� 8

Minimum breaking current mA 10 /� 5 V Maximum switching voltage V �/��250Electrical life 105 operations 8 A 250 V resistive

Mechanical life 5 x 106 operationsDielectric strength Conforming to IEC 1812-1 kV 2.5/1min/1 mA/50 HzImpulse voltage Conforming to

IEC 664-1, IEC 1812-1kV 5, wave 1.2/50 µs

Display characteristicsState indication by 1 LED Green Operating status indication

Pulsing: relay energised, no timing in progress (except Di-D and Li-L)

Flashing: timing in progress

On steady: relay energised, no timing in progress

Input characteristicsInput type V Volt-free contact (no potential)

Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer

References :pages 2/50 and 2/52

Dimensions :page 2/50

Schemes :page 2/52

2/49

2

Characteristics (continued) 2 Zelio Time - timing relays 2

Universal plug-in relays, 11-pin,relay output, width 35 mm

General characteristicsConforming to standards IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC

(� marking) + EMC (89/336/EEC + IEC 669-2-3)

Product certifications c UR us, CSA, GL

Temperature limits Operation °C - 20…+ 60

Storage °C - 30…+ 60

Creepage distanceand clearance

Conforming to IEC 60664-1 kV 4 kV/3

Degree of protectionconforming to IEC 529

Terminal block IP 20Enclosure IP 40Front panel IP 50

Vibration resistance Conforming to IEC 68-2-6 f = 10…55 HzA = 0.35 mm

Relative humiditywithout condensation

Conforming to IEC 68-2-3 93 %

Electromagneticcompatibility

Immunity to electrostatic discharge, conforming to IEC 1000-42

Level III (Air 8 kV/Contact 6 kV)

Immunity to electromagnetic fields, conforming to ENV 50140/204 (IEC 1000-4-3)

Level III 10 V/m : (80 MHz…1 GHz)

Immunity to fast transients in bursts, conforming to IEC 1000-4-4

Level III (direct 2 kV / capacitive connecting clip 1 kV)

Immunity to surges on the power supply, conforming to IEC 1000-4-5

Level III (common mode 2 kV / differential mode 1 kV)

Immunity to radio frequency interference in common mode conforming toENV 50141 (IEC 1000-4-6)

Level III (10 V rms : 0.15…80 MHz)

Immunity to voltage dips and breaks, conforming to IEC 1000-4-11

30 % / 10 ms60 % / 100 ms95 % / 5 s

Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)

Class B

Fixing Plug-in socket 11-pin

Enclosure material Self-extinguishing

References :pages 2/50 and 2/52

Dimensions :page 2/50

Schemes :page 2/52

2/50

2

References,dimensions,schemes 2

Zelio Time - timing relays 2

Universal plug-in relays, 11-pin,relay output, width 35 mm

Relay output, 2 C/O contacts� Multifunction, dual function or single function� Multi-range (7 switchable ranges)� Multivoltage� 2 relay outputs: 8 A - 250 V (10 A UL)� Plug-in� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control possible

Function diagramsFunction A Function C Function Ac

Delay on energisation2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Timing after opening of control contact2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Timing after closing and opening of control contact2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Function B Function Ht Function DiTiming on impulse, one shot2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Timing on energisation wih memory2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Symmetrical flashing, start with output in operating position2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

References

Connection Plug-in sub-base � � �

Functions Multifunction Dual function Single functionA - At - B - C - H - Ht - Di - D Ac - Bw

A - At C

Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hRelay output 2 timed contacts,

1 convertible to instantaneous2 timed contacts 2 timed contacts

Rated current 8 A 8 A 8 A

Voltages ��24 V / ��24…240 V RE 88 867 305 RE 88 867 415 RE 88 867 435�/��12 V – – –�/��12…240 V – – –

Weight (kg) 0.080 0.080 0.08011-pin socket (1)with connector

Mixed contact terminals (2) RUZ C3M RUZ C3M RUZ C3MWeight (kg) 0.054 0.054 0.054

(1) These products are sold in packs of 10(2) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the

opposite side of the socket.

Dimensions and connection schemesDimensions

U

R1/R2

R2 instT

U

C

R1/R2

∞ TR2 inst.

U

C

R1/R2T T

R2 Inst.

U

C

R1/R2∞ T

R2 Inst.t1

R1/R2

C

U

t2

T = t1+t2R2 Inst.

U

R1/R2T T

R2 Inst.

5611

80

5611

81

5611

81

45

3,5 12,5

74,535

Characteristics :pages 2/48 and 2/49

Dimensions :page 2/52

2/51

2

2

Function Bw Function At Function H Function D Function LPulse output (width adjustable)2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Delay on energisation with memory2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Timing on energisation2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Symmetrical flashing, start with output in rest position2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous

Asymmetrical flashing,Start with output in rest position2 timed contacts

Function LiAsymmetrical flashing,start with output in operating position2 timed contacts

� � �

Dual function Multifunction MultifunctionLi - L A - At - B - C - H - Ht - Di - D - Ac - Bw A - At - B - C - H - Ht - Di - D - Ac - Bw

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h2 timed contacts 2 timed contacts,

1 convertible to instantaneous2 timed contacts,1 convertible to instantaneous

8 A 8 A 8 A

RE 88 867 455 – –– RE 88 867 300 –– – RE 88 867 3030.080 0.080 0.080RUZ C3M RUZ C3M RUZ C3M0.054 0.054 0.054

Connection schemesAll functions except L and Li Functions L and Li

U

C

RT T

U

C

R1/R2t1 t2

T = t1+t2R2 Inst.

TR1/R2

U

R2 Inst.

U

T TR1/R2

R2 Inst.T1

R1/R2T2

U

T1R1/R2

U

T2

5611

80

5611

82

5611

82

U

4R1

Y1

R2

+

56

7

8

9

10111

2

3

U

(1)

4R1 R2

+

56

7

8

9

10111

2

3

Characteristics :pages 2/48 and 2/49

Dimensions :page 2/50

(1) Link between pins 2 and 5 for function L only.

2/52

2

Characteristics 2 Zelio Time - timing relays 2

Universal plug-in relays, 8-pin,relay output, width 35 mm

Timing characteristicsRepeat accuracy(with constant parameters)

Conforming to IEC 1812-1 ± 0.5 %

Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V

Full scale setting accuracy Conforming to IEC 1812-1 ± 10 % at 25 °C

Minimum duration of control impulse

Typical ms 30Typical under load ms 100

Maximum reset time by de-energisation

Typical ms 100

Immunity timeto microbreaks

Typical ms > 10

Supply characteristicsMultivoltage supply Depending on version, see pages 2/54 and 2/55Frequency Hz 50/60Operating range 85…110 Un % (85…120 Un for �/��12 V )

On-load factor 100 %Maximum power consumption

Depending on model

� 24 V W 0.6 � 240 V W 1.5

� 240 V VA 32

Output characteristicsOutput type Relay, 1 or 2 C/O contacts, AgNi (cadmium -free)Breaking capacity � 2000 VA, ��80 W

Maximum breaking current A ��8, �� 8Minimum breaking current mA 10/� 5 V Maximum switching voltage V �/��250

Electrical life 105 operations 8 A 250 V resistive Mechanical life 5 x 106 operationsDielectric strength Conforming to IEC 1812-1 kV 2.5/1min/1 mA/50 Hz

Impulse voltage Conforming to IEC 664-1,IEC 1812-1

kV 5, wave 1.2/50 µs

Display characteristicsState indication by 1 LED Green Operating status indication

Pulsing: relay energised, no timing in progress (except Di-D and Li-L)

Flashing: timing in progress

On steady: relay energised, no timing in progress

Input characteristicsInput type V Volt-free contact (no potential)

Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer

References :pages 2/54 and 2/55

Dimensions :page 2/54

Schemes :page 2/55

2/53

2

Characteristics (continued) 2 Zelio Time - timing relays 2

Universal plug-in relays, 8-pin,relay output, width 35 mm

General characteristicsConforming to standards IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC

(� marking) + EMC (89/336/EEC + IEC 669-2-3)

Product certifications c UR us, CSA, GL

Temperature limits Operation °C - 20…+ 60

Storage °C - 30…+ 60

Creepage distanceand clearance

Conforming to IEC 60664-1 kV 4 kV/3

Degree of protectionconforming to IEC 529

Terminal block IP 20Enclosure IP 40Front panel IP 50

Vibration resistance f = 10…55 HzA = 0.35 mm

Relative humiditywithout condensation

Conforming to IEC 68-2-3 93 %

Electromagneticcompatibility

Immunity to electrostatic discharge, conforming to IEC 1000-42

Level III (Air 8 kV/Contact 6 kV)

Immunity to electromagnetic fields, conforming toENV 50140/204 (IEC 1000-4-3)

Level III 10 V/m : (80 MHz…1 GHz)

Immunity to fast transientsin bursts conforming to IEC 1000-4-4

Level III (direct 2 kV / capacitive connecting clip 1 kV)

Immunity to surges on the power supply, conforming toIEC 1000-4-5

Level III (common mode 2 kV / differential mode 1 kV)

Immunity to radio frequency interference in common mode conforming to ENV 50141(IEC 1000-4-6)

Level III (10 V rms : 0.15…80 MHz)

Immunity to voltage dips and breaks conforming to IEC 1000-4-11

30 % / 10 ms60 % / 100 ms >95 % / 5 s

Radiated and mains conducted disturbanceconforming to EN 55022(EN 55011 Group 1)

Class B

Fixing Plug-in socket 8-pin

Enclosure material Self-extinguishing

References :pages 2/54 and 2/55

Dimensions :page 2/54

Schemes :page 2/55

2/54

2

References,dimensions,schemes 2

Zelio Time - timing relays 2

Universal plug-in relays, 8-pin,relay output, width 35 mm

Relay output, 1 or 2 C/O contacts� Multifunction of single function� Multi-range (7 switchable ranges)� Multivoltage� 1 or 2 relay outputs: 8 A - 250 V (10 A UL)� Plug-in� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option

Function diagramsFunction A Function C

Delay on energisation1 contact

2 timed contacts

Timing after opening of control contact1 timed contact

Function Di Function B Function HtSymmetrical flashing, start with output in operating position

Timing on impulse, one shot

Timing on energisation with memory

References

Connection Plug-in sub-base � � �

Functions Multifunction Single function Single functionA - At - B - C - H - Ht - Di - D Ac - Bw

A C

Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

Relay output 1 timed contact 2 timed contacts 1 timed contactRated current 8 A 8 A 8 AVoltages ��24 V / ��24…240 V RE 88 867 105 RE 88 867 215 RE 88 867 135

�/��12 V – – –�/��12…240 V – – –

Weight (kg) 0.080 0.080 0.080

8-pin socket (1)with connector

Mixed contact terminals (2) RUZ C2M RUZ C2M RUZ C2MWeight (kg) 0.054 0.054 0.054

(1) These products are sold in packs of 10.(2) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the

opposite side of the socket.

Dimensions and connection schemesDimensions

U

RT

U

R1/R2T

U

C

R∞ T

U

RT T

U

C

R∞ T t1

R

C

U

t2T = t1+t2

5611

77

5611

78

5611

78

45

3,5 12,5

74,535

Characteristics :pages 2/52 and 2/53

Schemes :page 2/55

2/55

2

22

Function L Function D Function At Function H Function LiAsymmetrical flashing,start with output in rest position

Symmetrical flashing,start with output in rest position

Delay on energisationwith memory

Timing on energisation

Asymmetrical flashing,start with output in operating position

Function Ac Function BwTiming after closing and opening of control contact

Pulse output (width adjustable)

� � �

Dual function Multifunction MultifunctionLi - L A - At - B - C - H - Ht - Di - D - Ac - Bw A - At - B - C - H - Ht - Di - D - Ac - Bw

1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h

1 timed contact 1 timed contact 1 timed contact8 A 8 A 8 ARE 88 867 155 – –

– RE 88 867 100 –– – RE 88 867 1030.080 0.080 0.080

RUZ C2M RUZ C2M RUZ C2M0.054 0.054 0.054

Connection schemesTiming relays with 1 relay outputAll functions except L and Li Functions L and Li

(1) Link between pins 2 and 6 for function L only.

Timing relays with 2 relay outputsFunction A

T1R

T2

U U

T TR

U

C

Rt1 t2

T = t1+t2

TR

U

T1R

U

T2

U

C

RT T

U

C

RT T

5611

79

5611

78

5611

78

U4

R

+

5

6

7

81

2

3

Y U (1)4

R

+

5

6

7

81

2

3

U4

R1 R2

+

5

6

7

81

2

3

Characteristics :pages 2/52 and 2/53

Dimensions :page 2/54

2/56

2

Characteristics 2 Zelio Time - timing relays 2

Miniature plug-in relays, relay output

Timing characteristicsRepeat accuracy (with constant parameters) ± 0.5 %Full scale setting accuracy Conforming to IEC/EN 61812-1 10 % at 25 °CTemperature drift 0.05 %/ °C

Maximum reset timeby de-energisation

During time delay period ms 50After time delay period ms 250

Immunity to microbreaks ms ≤ 5

Voltage drift ± 0.2 % / V

Output characteristicsOutput type Relay 2 and 4 cadmium-free C/O contacts

Rated current A � 5Rated insulation voltage V � 250Maximum breaking capacity (resistive) A 4 x 5

Maximum permissible current A 10 < 0.01 sMinimum breaking current mA 100Electrical life at I max ���� 250 V resistive 105 operating cycles

Mechanical life 107 operationsDielectric strength To IEC/EN 61812-1 and 60601-1 2 kV at 1 mA for 1 min at 50 Hz

General characteristicsConforming to standards IEC/EN 61812-1, 60601-1, 60601-2, EN 50081-2, 61000-6-2,

LV (73/23/EEC + 93/68/EEC) + EMC (89/336/EEC) directives

Product certifications UL-cULState indication by LED Output in operation Red LED

Power on Yellow LED

Permissible voltage variation � 12 V ± 10 %� 24 V ± 10 %��24 V ± 15 %

��120 V ± 15 %��230 V ± 15 %

Frequency Hz 50/60 ± 1

Maximum power consumption � 12 V W 1.5 �� 24 V W 1.2 ��24 V VA 1.7 �

��120 V VA 2.6 ���230 V VA 3

Temperature limits Operation °C - 20…+ 60

Storage °C - 40…+ 70Insulation voltage To standard VDE 0010

IEC 255 Group CV �/� 250

Degree of protection Conforming to IEC 60529 IP 50Overvoltage protection joules 2

Fixing Base-mounted On socketVibration resistance Conforming to IEC 60068-2-6,

10 to 55 Hza = 0.35 mm

Relative humidity Conforming to IEC 60068-2-3without condensation

95 % max

Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1/A11)Electrostatic discharge Conforming to IEC/EN 61000-4-2 Level 3 (Air 8 kV contact, 6 kV)

Electromagnetic fields Conforming to IEC/EN 61000-4-3 Level 3 (10 V/m)Fast transients Conforming to IEC/EN 61000-4-4 Level 3 (2 kV)Shock waves Conforming to IEC/EN 61000-4-5 Level 3 (2 kV)

Radio frequenciesin common mode

Conforming to IEC/EN 61000-4-6 Level 3 (10 V rms from 0.15 MHz to 80 MHz)

Voltage dips and breaks Conforming to IEC/EN 61000-4-11 30 %/10 ms, 60 %/100 ms and 1 s, > 95 %/5 sRadiated and conducted emissions

Conforming to EN 55022(EN 55011 group 1)

Class B

Creepage distanceand clearance

Conforming to IEC 60664-1 kV 4, in category 3

Internal schemesRelay with 4 C/O contacts

Relay with 2 C/O contacts

- 13

9

5 1

+ 14

6

10

2

11

7 3

12

8 4 - 13

9

5 1

+ 14

8

12

4

References :page 2/57

Dimensions :page 2/57

2/57

2

Functions,references,dimensions 2

Zelio Time - timing relays 2

Miniature plug-in relays, relay output

Relay output, 2 and 4 C/O contacts� Miniature and plug-in (21 x 27 mm)� Function A : on-delay� 7 timing ranges: 0.1 s to 100 h� Excellent immunity to interference� Power on and relay energised indication by 2 LEDs

Function diagramsFunction A

Delay on energisation4 timed C/O contacts

2 timed C/O contacts

References

Functions Single function A

Timing ranges 7 switchable ranges 0.1 s…1 s - 1 s…10 s - 0.1 min…1 min - 1 min…10 min - 0.1 h…1 h - 1 h…10 h - 10 h…100 hRelay output 4 timed C/O contacts 2 timed C/O contactsRated current ��5 A ��5 A

Voltages ��12 V RE XL4TMJD RE XL2TMJD��24 V (1) RE XL4TMBD RE XL2TMBD��24 V 50/60 Hz (1) RE XL4TMB7 RE XL2TMB7��120 V 50/60 Hz RE XL4TMF7 RE XL2TMF7��230 V 50/60 Hz RE XL4TMP7 RE XL2TMP7

Weight (kg) 0.050 0.050

Sockets (2) with mixed contact terminals (3)

With screw clamp terminals RXZ E2M114 (5) RXZ E2M114 (5)Weight (kg) 0.048 0.048With connector RXZ E2M114M (5) RXZ E2M114M (5)

Weight (kg) 0.056 0.056Sockets (2) withseparate contact terminals (4)

With connector RXZ E2S114M (6) RXZ E2S108M (6)Weight (kg) 0.058 0.070

(1) For � 48 V supply, additional resistor 560 Ω 2 W / ��24 V. For ��48 V supply, additional resistor 390 Ω 4 W / ��24 V.(2) These products are sold in lots of 10.(3) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the

opposite side of the socket.(4) The inputs and outputs are separated from the relay supply terminals.(5) Thermal current Ith: 10 A(6) Thermal current Ith: 12 A

Dimensions and terminal referencingDimensions Terminal referencing

RE XL4TM��������

13-14

1-5-9

4-8-12T

2-6-10

3-7-11

13-14

1-5-9

4-8-12T

5325

35

5325

36

27

21

27

21

RE XL2TM��������

R Un

21 65,53,5

27

59,5

0,55

2,8

0,31,2

159

13

(-)

26

10

37

11

48

1214

(+)

159

13

(-)

48

1214

(+)

Characteristics :page 2/56

Schemes :page 2/56

2/58

2

Presentation 2 Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

The range of RE 48A timing relays, in 48 x 48 housing, is specially designed for integration in machines and equipment. It is suitable for applications requiring frequent modification or adjustment of the timing cycles.

RE 48A relays have the following characteristics:� All references are multivoltage 24 to 240 V � and � and are therefore suitable for the majority of applications while at the same time reducing the number of products to be stocked.

� The timing ranges covered are from 0.02 s to 300 h.

� These timing relays can be panel-mounted using the spring clip supplied as standard, or DIN rail-mounted using standard sockets.

� Two LED's on the front face provide immediate indication of the timing status: � power ON,� output relay state,� timing in progress.

The size of the knob and clear indication of the timing scale allow easy adjustment, eliminating any errors during parameter setting.In addition, in applications where only the timing cycle value is left freely accessible to users, a protective cover can be used to block access to the other settings.

This range is comprises 4 references:

(1) This relay features control inputs which provide a wider choice of timing modes:Start Input to control the start of timing,Gate Input to suspend the timing in progress without cancelling it,Reset Input to reset timing to its initial state during the cycle.

Presentation

Reference DescriptionRE 48A TM12MW Single function

� On-delay� two relay outputs

RE 48A CV12MW Dual function� asymmetrical flasher� two relay outputs

RE 48A MH13MW Multifunction� On-delay and pulse-on energisation� two relay outputs, of which one selectable and

instantaneous

RE 48A ML12MW (1) Multifunction� On-delay� timing on impulse� Off-delay� symmetrical flasher

Characteristics : pages 2/60 and 2/61

Function diagrams :page 2/62

References :pages 2/63 and 2/64

Dimensions :pages 2/63 and 2/64

Mounting :page 2/65

2/59

2

Description 2 Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

DescriptionRE 48A TM12 MW timing relays have the following on the front face :

1 A time base selector knob (12 and 30)2 A time unit selector knob (x 0.1 s, x 1 s, x 10 s, x 1 min, x 10 min, x 1 h, x 10 h)3 A timing adjustment knob4 A yellow LED, indicating the status of the output relay5 A green LED, indicating power ON (flashing during the timing period).

RE 48A CV12 MW timing relays have the following on the front face :

1 A time base selector knob (12 and 30)2 Two time unit selector knobs (x 0.1 s, x 1 s, x 10 s, x 1 min, x 10 min, x 1 h,

x 10 h)3 An orange button for setting the pulse time4 A white button for setting the pause time5 A yellow LED, indicating the status of the output relay6 A green LED, indicating power ON (flashing during the timing period).

RE 48A M�1� MW timing relays have the following on the front face :

1 A time base selector knob (12 and 30)2 A time unit selector knob (x 0.1 s, x 1 s, x 10 s, x 1 min, x 10 min, x 1 h, x 10 h)3 A function selector knob:

A, B, C, Di for RE 48A ML12 MWA1, A2, H1, H2 for RE 48A MH13 MW

4 A timing adjustment knob5 A yellow LED, indicating the status of the output relay6 A green LED, indicating power ON (flashing during the timing period).

1

5

4 3 2

5219

34

1

6

3

25 24

5219

35

1

45

6

23

5219

36

Characteristics : pages 2/60 and 2/61

Function diagrams :page 2/62

References :pages 2/63 and 2/64

Dimensions :pages 2/63 and 2/64

Mounting :page 2/65

2/60

2

Characteristics 2 Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

General characteristicsConforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC

�����marking) + EMC directive (89/336/EEC + IEC 60669-2-3)

Approvals UL, cULus, C-Tick, CSA, GL

Ambient air temperature around the device

Storage °C - 40…+ 70

Operation °C - 20…+ 50

Degree of protectionconforming to IEC 60529

Housing IP 40Front face IP 50

Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 HzA = 0.35 mm

Relative humidity without condensation

Conforming to IEC 60068-2-3 93 %

Electromagnetic compatibility Immunity to electrostatic discharge,conforming to IEC/EN 61000-4-2

Level III (Air 8 kV/Contact 6 kV)

Immunity to electromagnetic fieldsconforming to IEC/EN 61000-4-3

Level III (10 V/m: 26 MHz…1 GHz)

Immunity to fast transients in bursts,conforming to IEC/EN 61000-4-4

Level IV (direct 4kV / capacitive connecting clip 2 kV)

Immunity to surges on the power supplies,conforming to IEC 61000-4-5

Level III (common mode 2 kV / differential mode 1 kV)

Immunity to radio frequency interference in common mode, conforming to IEC/EN 61000-4-6

Level III (10 V rms: 0.15…80 MHz)

Immunity to voltage dips and breaks,conforming to IEC/EN 61000-4-11

30 % / 10 ms60 % / 100 ms95 % / 5 s60 % / 1 s

Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)

Class B (0.15...30 MHz)

Fixing Panel-mounting Using mounting system (supplied with the product)Base-mounted With socket

Connection By socket or connector

Housing material Self-extinguishing

Input characteristicsType of input by volt-free contact

Start: starts the function (only for functions A, B, C and Di on RE 48A ML12 MW)Gate: stops timing in progressReset: resets the relay, output to OFF

Output characteristicsOutput type Relay with 2 timed changeover contacts (except RE 48A MH13 MW: relay with

1 timed changeover contact and 1 instantaneous changeover contact) Contact type AgNi (cadmium-free)

Breaking capacity VA � 1250Maximum breaking current A � 5 for 250 VMinimum breaking current mA 100/� 12 V

Maximum switching voltage V �/� 250Electrical durability 105 operationsMechanical durability 30 x 106 operations

Dielectric strength Conforming to IEC 61812-1 kV 1/1minElectric shock resistance Conforming to

IEC 60664-1, IEC 61812-1kV 4, category 3

Rated operational voltage � AC-12 Ue = 240 V and Ie = 5 A� AC-15 Ue = 240 V and Ie = 1.5 A

� DC-13 Ue = 30 V and Ie = 2 A

Presentation, description : pages 2/58 and 2/59

Function diagrams :page 2/62

References :pages 2/63 and 2/64

Dimensions :pages 2/63 and 2/64

Mounting :page 2/65

2/61

2

Characteristics 2 Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

Supply characteristicsSupply voltage V �/��24…240

Frequency Hz 50/60

Operating range � - 15 %...+ 10 %� - 10 %...+ 10 %

On-load factor 100 %

Maximum power consumption

Depending on model

� 24 V W 0.5� 24 V VA 1.1 � 240 V W 1.7

� 240 V VA 4.8

Timing characteristicsSelectable timing ranges by selector switch on front face s

Time unit Time scale0.02…1.2 x 0.1 s 12

0.05…3 x 0.1 s 300.2…12 x 1 s 120.5…30 x 1 s 30

2…120 x 10 s 125…300 x 10 s 30

min 0.2…12 x 1 min 12

0.5…30 x 1 min 302…120 x 10 min 125…300 x 10 min 30

h 0.2…12 x 1 h 120.5…30 x 1 h 302…120 x 10 h 12

5…300 x 10 h 30

Repeat accuracy(with constant parameters)

Conforming to IEC 61812-1 ± 0.2 % of the maximum setting value

Driftconforming to IEC 61812-1

Temperature ± 0.02 %/°C of the maximum setting valueHumidity ± 0.05 %/%HR of the maximum setting valueVoltage �/� 24...48 V: ± 1 %/V of the maximum setting value

�/� 48...240 V: ± 0.2 %/V of the maximum setting valueSetting accuracy at full scale Conforming to IEC 61812-1 ± 5 % at 25 °C

Minimum control pulse duration on the Gate/Start/Reset input

Typical ms 20

Minimum reset time by de-energisation ms 25

Delay on pick-up ms 55

Immunity to microbreaks ms < 10

Display characteristicsState indication Green LED Flashing: timer energised, timing in progress

On steady: timer energised, relay energised, no timing in progressYellow LED On: output relay ON

Off: output relay OFF

Presentation, description : pages 2/58 and 2/59

Function diagrams :page 2/62

References :pages 2/63 and 2/64

Dimensions :pages 2/63 and 2/64

Mounting :page 2/65

2/62

2

Functions 2 Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

Function diagramsRE 48A TM12 MW RE 48A CV12 MWFunction A Function L Function Li

Delay on energisation Asymmetrical flashing, start with output in rest position

Asymmetrical flashing, start with output in operating position

RE 48A ML12 MWFunction A Function B

Delay on energisation Timing on impulse, one shot

Function C Function DiTiming after opening of control contact Symmetrical flashing, start with output in operating position

RE 48A MH13 MWFunctions A1, A2 Functions H1, H2

Delay on energisation Pulse-on energisation

Note : If A1 or H1 are selected, only R2 is timed, R1 is instantaneous

T T

Un

R

t3 ta tc

t2 tb

t1

Un

Gate

2 - 6Nor / Inv

Toff

Ton

Toff = t1+t2+t3 Ton = ta+tb+tc

R

Toff Toff

Ton

t3 ta

t2 tb

t1 t1

Un

Gate

2 - 6Nor / Inv

Ton

Ton = t1+t2+t3 Toff = ta+tb+tc

R

Toff

Ton

T Tt2

T = t1 + t2 + t3

t1 t3 T T T Tt

Un

Start

Gate

Reset

R

T T T t1 t3

t2

T = t1 + t2 + t3

T T T

Un

Start

Gate

Reset

R

T T t1 t3

t2T = t1 + t2 + t3

T T

Un

Start

Gate

Reset

Output

T T T T T Tt1t2

T = t1 + t2

t1 t2 T T T T T T T T TT T T TT

Un

Start

Gate

Reset

Output

T T

Un

R2

R1

T T

Un

R2

R1

Presentation, description : pages 2/58 and 2/59

Characteristics : pages 2/60 and 2/61

References :pages 2/63 and 2/64

Dimensions :pages 2/63 and 2/64

Mounting :page 2/65

2/63

2

References,dimensions 2

Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

References

Plug-in 8-pin 11-pin 11-pin 8-pinFunctions Single function Dual function Multifunction Multifunction

A L, Li A, B, C, Di A1, A2, H1, H2

Timing ranges 1.2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 hRelay output 2 C/O timed contacts 2 C/O timed contacts 2 C/O timed contacts 1 C/O timed contact

1 C/O instantaneous contact

Rated current 2 x 5 A 2 x 5 A 2 x 5 A 2 x 5 AVoltages �/��24…240 V RE 48A TM12 MW RE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MWWeight (kg) 0.140 0.140 0.140 0.140

DimensionsRE 48A �������� 1���� MW

4844,4

Ø39

6,8 64,5 15,5 48

96,8

Presentation, description : pages 2/58 and 2/59

Characteristics : pages 2/60 and 2/61

Mounting :page 2/65

5219

38

5219

37

5219

39

5219

39

2/64

2

References,dimensions 2

Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

ReferencesDescription Number

of pinsFor use with

Sold in lot of

Unit reference

Weightkg

IP 20 socketswith screw terminal connections and mixed contact terminals (1)

8 RE 48A TM12 MW, RE 48A MH13 MW

10 RUZ C2M 0.054

11 RE 48A CV12 MW, RE 48A ML12 MW

10 RUZ C3M 0.054

IP 20 socket with screw terminal connections on rear face

11 RE 48A CV12 MW, RE 48A ML12 MW

1 RE 48A SOC11 AR –

IP 20 solder connectors

8 RE 48A TM12 MW, RE 48A MH13 MW

1 RE 48A SOC8 SOLD –

11 RE 48A CV12 MW, RE 48A ML12 MW

1 RE 48A SOC11 SOLD –

Setting protection cover

– RE 48A TM12 MWRE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MW

1 RE 48A SET COV –

IP 64 protective cover – RE 48A TM12 MWRE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MW

1 RE 48A IP COV –

(1) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the opposite side of the socket.

RUZ C3M

RE 48A SOC11 AR

RE 48A SOC8 SOLD RE 48ASOC11 SOLD

RE 48A SET COV RE 48A IP COV

DimensionsCommon side view 8-pin socket 11-pin socketRUZ C����M RUZ C2M RUZ C3M

11-pin socket 8-pin connector 11-pin connectorRE 48A SOC11 AR RE 48A SOC8 SOLD RE 48A SOC11 SOLD

75

27

22

38

30

24

6

27

A2

7

A1

2

11

1

21

8

A2

7

INPUT A2INPUT A1

22

5

12

4

1

4

2

3

8

5

7

6

14

3

2xØ3,1

37

38

37

30

A2

10

A2

10

31

11

21

6

11

1

A1

2

34

9

32

8

24

7

22

5

14

3

12

4

210

1

6

2

5

3

4

1110

7

9

8

INPUT A2INPUT A1

2xØ3,1

==

46

4620

Ø30

34

Ø30

34

Presentation, description : pages 2/58 and 2/59

Function diagrams :page 2/62

Characteristics : pages 2/60 and 2/61

2/65

2

Mounting,schemes 2

Zelio Time - timing relays 2

Electronic relays, relay output, 48 x 48 housing

MountingCover positioning and mounting Panel cut-out

e : panel thickness(1) IP 64 protective cover: RE 48A IP COV(2) Panel mounting frame(3) Locating screw

n : Number of devices mounted side-by-side

Connection schemesRE 48A TM12 MW RE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MW

e (2)

(3)17

20

(1)

15

30

1

U

R2

3

4 5

8

7

6

6 75 84

93

111

102

U

R

Gate 6 75 84

93

111

102

U

R

Reset

Start

Gate1

U

R1 R22

3

4 5

8

7

6

Presentation, description : pages 2/58 and 2/59

Function diagrams :page 2/62

Characteristics : pages 2/60 and 2/61

2/66

2

Characteristics 2 Zelio Time - timing relays 2

Panel-mounted, plug-in, universal relays

Display characteristicsNumber of digits 4Digit height mm 8

Timing characteristicsRepeat accuracy (with constant parameters) ± 0.03 % ± 20 ms

Full scale setting accuracy ± 0.03 % ± 20 msMinimum duration of control impulse ms 50Maximum reset time byde-energisation

During time delay period ms 50

After time delay period ms 50

Output characteristicsRelay type RE 88 857 40�������� RE 88 857 10����

RE 88 857 00���� RE 88 857 30��������

Rated current A ��5, ��5 ��8, ��8 ��8, ��8Maximum switching voltage V ��250, ��30 ��250, ��30 ��250, ��30

Maximum breaking capacity on resistive load

� VA 1250 2000 2000� W 120 190 190

Maximum permissible current A 15 < 0.01 s

Minimum current mA 100Electrical life at I max, ���� 250 V resistive 105 cyclesMechanical life 5 million operating cycles

General characteristicsConforming to standards IEC 255, VDE 0435-2021Product certifications c UR us, CSAPermissible voltage variation - 15…+ 10 % - 15…+ 10 % - 15…+ 10 %

Immunity to microbreaks s < 0.03 < 0.03 < 0.03Maximum powerconsumption

��12 V W – 0.5 0.��24 V W 0.5 0.5 0.5

��48 V W – 1 1��24 V VA 1 1 1��48 V VA – 2 2

��110 V VA 3.5 3.5 3.5��220 V VA 11 11 11

Temperature limits Operation °C - 10…+ 60

Storage °C - 30…+ 70Front panel degree of protection IP 65Insulation Conforming to standard VDE 0110 and IEC 225 Group C

Protection class Conforming to UTE C 20010, IEC 529, DIN 40050Fixing Panel-mounted By clip

Base-mounted On socket

Material Self-extinguishing UL 94 grade Vo

Functions :page 2/68

Schemes :page 2/67

References :page 2/69

Dimensions :page 2/69

2/67

2

Schemes 2 Zelio Time - timing relays 2

Panel-mounted, plug-in, universal relays

Internal schemesRelay RE 88 857 40����

Relay RE 88 857 10����

Relay RE 88 857 00����

Relay RE 88 857 30����

Terminal referencing

(1) Another load may be connected.

RelayRE 88 57 40��������

RE 88 857 10��������

RE 88 857 00��������

RE 88 557 30��������

Supply 2-10 – � – �

Supply 2-7 � – � –Link 2-11 : � 12 V or �/� 24 V – � – –Link 2-7 : � 12 V or �/� 24 V – – – �

Link 2-8 : � 12 V or �/� 24 V – – � –2-5 or 2-6 control or reset contact – � � �

1-3-4 timed output contact � � � �

8-5-6 timed output contact � – – –8-9-11 timed or instantaneous output contact – – – �

7

2 1

3 4

8

6 5

1

10 3 4

5 2

-

+

11 1

7 3 4

6 2

-

+

8 1

10 3 4

11

9 8

2

-

+

7

6

781

2

34 5

~+U

~

+~

9

U

6 78

10111

234

5

-~

Start

(1) 6

7

812

34 5

~+U

~

Start

(1) 9

U

6 78

10111

234

5

~+

~

(1)

Reset

Characteristics :page 2/66

Functionspage 2/68

References :page 2/69

Dimensions :page 2/69

2/68

2

Functions 2 Zelio Time - timing relays 2

Panel-mounted, plug-in, universal relays

Relay output, 1 or 2 contacts� Multifunction or single function� Multi-range� Multivoltage � 1 or 2 relay outputs� Reset function on front panel (RE 88 857 30����)� Memory in the event of mains power failure (RE 88 857 30����)� Locking of access to programming(RE 88 857 10���� and RE 88 857 00����)� Upcount or downcount mode� Internal supply by lithium battery (10 years at 20 °C)

Function diagramsFunction A Function A1 Function A2

Delay on energisation1 timed contact

Delay on energisation1 timed contact1 instantaneous contact

Delay on energisation2 timed contacts

Function AM Function AMt Function BDelay on energisationMemory during the time delay period. Reset

Delay on energisationMemory during and after the time delay period. Reset

Timing on impulse, one shot

Function C Function D Function DiOff-delay

Flashing relay

Flashing relay

Function HTiming on energisation

2-10

1-3-4

T

2-10

8-9-11

Tt1<T t2<T

1-3-4

2-10

1-3-4

8-9-11

Tt1<T t2<T

2-5

Tt1 T=t1+t2

1-3-4

8-9-11

t

2-10

t2

2-5

Tt1 T=t1+t2

1-3-4

8-9-11

2-10

t2

2-10

2-5

T

1-3-4∞

2-10

2-5

1-3-4∞ T

2-10

1-3-4

T T T T T

2-10

1-3-4

T T T T T

2-10

1-3-4

T

Characteristics :page 2/66

Schemes :page 2/67

References :page 2/69

Dimensions :page 2/69

2/69

2

References,dimensions 2

Zelio Time - timing relays 2

Panel-mounted, plug-in, universal relays

References

Plug-in 8-pin 11-pin 8-pin 11-pinFunctions Single function Multifunction Multifunction Multifunction

A A, B, C, D, Di, H A, B, C, D, Di, H A1, A2, AM, AMtTiming ranges 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h,

999.9 h, 9999 hRelay output 2 timed C/O

contacts1 timed C/O contact 1 timed C/O contact 1 timed C/O contact

1 timed or instantaneousC/O contact

Rated current 2 x 5 A 8 A 8 A 2 x 8 A

Voltages ��12 V and ��or�� 24…48 V – RE 88 857 103 RE 88 857 003 –��12 V and ��or�� 42…48 V – – – RE 88 857 302��or���24 V RE 88 857 409 – – –

��or���24 V and � 110 V – – – RE 88 857 307� or�� 24 V and � 110…240 V – RE 88 857 105 RE 88 857 005 –� or�� 24 V and � 220…240 V – – – RE 88 857 301��110 V RE 88 857 406 – – –��220…240 V RE 88 857 400 – – –

Weight (kg) 0.140 0.100 0.100 0.140

Socket (1) 8-pin RUZ 1D – RUZ 1D –11-pin – RUZ 1A – RUZ 1AWeight (kg) 0.067 0.067 0.067 0.067

(1) These products are sold in packs of 10.

Dimensions

Panel cut-out

5611

90

5611

91

5611

91

5611

92

48

48

9,71674,2

VALID MODE

45+0.6 0

45+

0.6

0

Characteristics :page 2/66

Schemes :page 2/67

Functions :page 2/68

2/70

2

Characteristics,schemes 2

Zelio Time - timing relays 2

Panel-mounted, plug-in, universal relays

Display characteristicsNumber of digits 4Digit height mm 7

Timing characteristicsRepeat accuracy (with constant parameters) ± 0.03 % ± 20 msFull scale setting accuracy ± 0.03 % ± 20 msMinimum duration of control impulse ms 50

Maximum reset timeby de-energisation

During time delay period ms 50After time delay period ms 50

Output characteristicsRated current A ��8, ��8Maximum switching voltage V ��250, ��30Maximum breaking capacity on a resistive load � VA 2000

� W 190Maximum permissible current A 15 < 0.01 sMinimum current mA 100

Electrical life at I max ���� 250 V resistive 100 000 operating cyclesMechanical life 5 million operating cycles

General characteristicsProduct certifications u UR cs, CSAConforming to standards IEC 255, VDE 0435-2021Permissible voltage variation - 15 …+ 10 %

Immunity to microbreaks s < 0.03Maximum powerconsumption

� 24 V W 0.5� 48 V W 1.5

��24 V VA 1��48 V VA 1.5��110 V VA 4

��230 V VA 12Temperature limits Operation °C - 10…+ 60

Storage °C - 30…+ 70

Front panel degree of protection IP 65Insulation Conforming to standards VDE 0110 and IEC 225 Group CProtection class Conforming to standards UTE C 20010, IEC 529, DIN 40050

Fixing Panel-mounting By clipBase-mounted On socket

Material Self-extinguishing UL 94 grade Vo

Internal schemesTerminal referencing

(1) Another load may be connected.

8-pin relay

11-pin relay

2-10 or 2-7 supply � �

Link (2-11) or (2-8) �/ � 24 V supply � �

2-5 or 2-6 control or reset contact � �

1-3-4 timed output contact � �

1

7 3 4

6 2 8

-

+

1

10 3 4

5 2 11

-

+

6

7

812

34 5

~+

U

~

Start

(1)

+~

9

U

6 78

10111

234

5

-~

Start

(1)

References :page 2/71

Dimensions :page 2/71

2/71

2

Functions,references,dimensions 2

Zelio Time - timing relays 2

Panel-mounted, plug-in, universal relays

Relay output, 1 C/O contact� Red illuminated display� Multifunction� Multi-range� Multivoltage � 1 relay output� Locking of access to programming� Upcount or downcount mode� Internal supply by lithium battery (10 years at 20 °C)

Function diagramsFunction A Function B Function C

Delay on energisation1 timed contact

Timing on impulse, one shot

Off-delay

Function D Function Di Function HFlashing relay

Flashing relay

Timing on energisation

References

Plug-in 8-pin 11-pinFunctions Multifunction Multifunction

A, B, C, D, Di, H A, B, C, D, Di, HTiming ranges 99.99 s, 999.99 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h,

999.9 h, 9999 hRelay output 1 timed C/O contact 1 timed C/O contactRated current 8 A 8 A

Voltages � or � 24 V and � or � 48 V RE 88 857 604 RE 88 857 704� or � 24 V and � 110 V, 50/60 Hz

RE 88 857 607 RE 88 857 707

� or � 24 V and � 24…240 V, 50/60 Hz

RE 88 857 601 RE 88 857 701

Weight (kg) 0.100 0.100Socket (1) 8-pin RUZ 1D –

11-pin – RUZ 1AWeight (kg) 0.067 0.067

(1) These products are sold in packs of 10.

Dimensions

Panel cut-out

2-10

1-3-4

T

2-10

2-5/6

T

1-3-4

2-10

2-5/6

1-3-4∞ T

2-10

1-3-4

T T T T T

2-10

1-3-4

T T T T T

2-10

1-3-4

T

5614

61

MODEVALID

9,7

74,2 16

48

48

45+ 0,6 0

45+

0,6

0

Characteristics :page 2/70

Schemes :page 2/70