4
2 Asia Regional Office Europe Regional Office www.systel.asia Pilestraede 58, 1112 Copenhagen Denmark. Ph : +45 36990422 [email protected]

2 ...2 Asia Regional Office Europe Regional Office Pilestraede 58, 1112 Copenhagen Denmark. Ph : +45 36990422 [email protected] Authorised Distributors Of : WAFS - 104 / 105 Thermal

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • 2

    Asia Regional Office Europe Regional Office

    www.systel.asia

    Pilestraede 58, 1112 CopenhagenDenmark. Ph : +45 36990422

    [email protected]

  • 2

    Asia Regional Office Europe Regional Office

    www.systel.asia

    Pilestraede 58, 1112 CopenhagenDenmark. Ph : +45 36990422

    [email protected]

  • WAFS - 104 / 105 Thermal Mass Flow Sensor

    Full Digital Signal Processing for Higher Precision

    and Better Stability

    Thermal Mass Flow, Independent of Temperature andPressure Change, Integrated Temperature MeasurementUltra-Wide 1:2500 Turndown Ratio, Measurement Rangefrom 0.1 Nm/s to 250 Nm/sFull Electrical Isolation thoroughly Filter out Disturbance2.8" Ultra-Wide Viewing Angle LCD with Capacitive Touch No Moving Parts, Low Pressure DropOptional Data Logging, 10,000,000 Recording PointsWith Bluetooth Function for Wireless Sensor Configurationand Data Transmission

    Standard RS485 Modbus RTU Interface and 4-20mAcurrent / pulse Output

    Insertion Type WAFS - 104:Suitable for DN20 to DN1000, can be Installed Online through 1/2" Ball Valve under Pressure

    Inline Type WAFS - 105:Pipe Size : DN15, DN20, DN32, DN40, DN50, DN65, DN80Connection : R Thread, Flange EN1092-1 , ANSI/B16.5Measures Standard Flow, Mass Flow, Consumption and Temperature

    No Moving Parts, Stable Signal, Vibration Proof, High Reliability, Long-Term Measurement Accuracy

    Full Digital Signal Processing instead of Traditional Analog Bridge Design, making the Flow Meter more Accurate and Capable of Wider Measuring Range

    2.8" Ultra - Wide Viewing Angle LCD with Capacitve Touch

    2

    Asia Regional Office Europe Regional Office

    www.systel.asia

    Pilestraede 58, 1112 CopenhagenDenmark. Ph : +45 36990422

    [email protected]

    Authorised Distributors Of :

    Flow Range

    Accuracy

    Sample Rate

    Reference Cond

    Analog (Standard)

    Digital (Standard)

    Wireless

    Connector

    Process Conn

    EMC

    Op. Temp

    Medium Temp

    Op. Pressure

    Display

    Data Logger

    Input

    0(0.1) … 250 Nm/s

    ±(1% reading + 0.3% Full Scale)

    Sample Rate

    20°C, 1 bar(a) - ISO 1217 (Programmable)

    4…20 mA (Isolated) / Pulse Output

    RS485, MODBUS RTU Protocol

    Bluetooth (Standard), Lora (Option)

    2 x 5 - pin M12,Female

    G1/2” (ISO 228-1)

    According to IEC 61326-1

    -30 … +70 °C

    -40 … 150 °C

    WAFS - 104 : 0…5.0 MPa (>1.6 MPa need

    Installation Device)

    WAFS - 105 : 1.6 MPa (Option:4.0 MPa)

    2.8”LCD with Capacitive Touch Panel

    10,000,000 Samples

    18…30V / 5W

    Measuring Range

    Communication Output

    Others

    Operating Environment

    Display / Data Logger

    Power Supply

    Technical Data WAFS - 104

    WAFS - 104

    WAFS - 105

  • 2

    Asia Regional Office Europe Regional Office

    www.systel.asia

    Pilestraede 58, 1112 CopenhagenDenmark. Ph : +45 36990422

    [email protected]

    Authorised Distributors Of :

    WAFS - 104 / 105 Thermal Mass Flow Sensor

    Flow Ranges WAFS - 104 Flow Ranges WAFS - 105

    20253240506580100125150200250300

    Min flow(cfm)

    Max flow(cfm)

    20253240506580100125150200250300

    0.060.120.180.290.410.711.061.652.593.776.6510.4214.95

    79124204319499843127819963120449379861247917970

    166260425666104017572662416064999360166392599937439

    1520253240506580

    0.040.060.120.180.290.410.711.06

    45791252043194998431278

    DN DNID (mm) ID (mm)Min flow (cfm)WAFS-104 Std Range

    Max flow (cfm)WAFS-104 High Range

    Max flow (cfm)

    1520253240506580

    Ordering CodesWAFS - 104

    A

    WAFS - 105 A

    B

    B

    C

    D

    E

    F

    Thermal Mass Flow Sensor Insertion Type 400mm

    Shaft, 0 ..250 Nm/s with 2.8” IPS Wide Viewing

    Angle LCD with Capacitive Touch Panel

    Thermal Mass Flow Sensor Inline Type 0 - 16 Bar (g),

    2.8” IPS Wide Viewing Angle LCD with Capacitive

    Touch Panel, R Thread, DN 20, 3/4”

    Thermal Mass Flow Sensor Inline Type 0 - 16 Bar (g),

    2.8” IPS Wide Viewing Angle LCD with Capacitive

    Touch Panel, R Thread, DN 25, 1”

    Thermal Mass Flow Sensor Inline Type 0 - 16 Bar (g),

    2.8” IPS Wide Viewing Angle LCD with Capacitive

    Touch Panel, R Thread, DN 32, 1.25”

    Thermal Mass Flow Sensor Inline Type 0 - 16 Bar (g),

    2.8” IPS Wide Viewing Angle LCD with Capacitive

    Touch Panel, R Thread, DN 40, 1.5”

    Thermal Mass Flow Sensor Inline Type 0 - 16 Bar (g),

    2.8” IPS Wide Viewing Angle LCD with Capacitive

    Touch Panel, R Thread, DN 50, 2”

    Thermal Mass Flow Sensor Inline Type 0 - 16 Bar

    (g), 2.8” IPS Wide Viewing Angle LCD with

    Capacitive Touch Panel, R Thread, DN 15, 1/2”

    Thermal Mass Flow Sensor Insertion Type 250mm

    Shaft, 0 ..250 Nm/s with 2.8” IPS Wide Viewing

    Angle LCD with Capacitive Touch Panel

    Thermal Mass Flow meters are Widely used in Industrial Processes,

    Chemical, Petrochemical, Power Engineering, etc.

    Compressed Air Consumption Measurement.

    Determination of Gas Leakage / Leakage Rate.

    Gas Consumption Measurement of a Single Machine / Plant/

    Process Gas Measurement, such as Nitrogen, Carbon Dioxide,

    Oxygen, etc

    Nitrogen Generator

    Applications :