100'
60'
MULBERRY DR
COLE
RDLAMBERT RD
COLIM
A RD
SCOT
T AV
E
WHITTIER BLVD
LEFFINGWELL RD
LA M
IRAD
A BL
VD
PROJECT SITE
LOS ANGELES
LOS ANGELES COUNTY PUBLIC WORKS
NOT TO SCALE
CULVER CITY
BEVERLY HILLS
CANYON RES.
MONICASANTAMONICA
SANTA
LINCOLN
BLV
D.
DIE
GO FRANKLIN
RES.CANYONSTONE LOWER
UPPERDR.
RES.
HY.
SANTA
MULHOLLAND
RES.CHATSWORTH
SIMI
COUNTY
RD
. HILLSHIDDEN HILLSHIDDEN
BLV
D.
HANSEN
GOLDEN
BURBANKFW
Y.
DAM
FWY.
FOO
THILL
SAN FERNANDO
MT
.
RD.
RES.
VALLEY
SEPULVEDA
SAN FERNANDO
VENTURA
F. C. BASIN
ENCINO
HO
LLYWO
OD
STATE
DR. SA
N
LIVE OAK RES.HUNTINGTONFOOTHILL
FWY
.
MAYWOOD
BERNARDINO
SO. PASADENA
ALHAMBRA
SAN MARINO
LAKELEGG
COLORADO
SANTA ANA
BELL
MONTEBELLO
COMMERCEPOMONA
BELL
ROSEMEAD
PASADENA
SAN GABRIELFWY.
FW
Y.
SAN
PARKMONTEREY
WHITTIER
RO
SEM
EAD
RIV
ER
ARCADIA
SO. EL
TEMPLE CITY
MONTE
BLV
D.BLVD.
VERNON
FWY.
FWY.
BLVD.
FWY
.IE
ND
A
RES.PUDDINGSTONE
ALOSTA AVE.
ORA
NGE
BLV
D.
LA PUENTE
INDUSTRY
WALNUT
AZUSAIRWINDALE
COVINA
FWY.
BLVD.
FWY
.
FWY.
SAN
FWY.
LA VERNE
POMONA
FWY.
SAN
CLAREMONT RES.
BLVD.
FOOTHILL
SAWPIT CANYONRES.
DUARTE
AN
GE
LES
CR
ES
T H
Y.
RES.SANTA ANITA
MT. WILSON
ANGELESANGELES
RD.
CANYON
SIERRA MADRE
FW
Y.
PASADENA MONROVIAFWY.
BLVD.
CA
NY
ON
SAN GABRIEL
CR
YSTA
LR
D. RESERVOIR
COGSWELL RESERVOIR
LAK
E
RD
.
BRADBURY
GLENDORA
RES.BIG DALTON
GABRIE
L
RES.SAN DIMAS
CREEKTHOMPSON
BOUQUET CANYON RES.
VALLEY
CAN
YON
FRA
NC
ISQ
UIT
O
DR.HENRY MAYO
FOOT
ANTELOPESIE
RRABOUQUET
SAN
SA
ND
PACOIMARES.
RD
. CANYON
SAN
RD
.
SA
N
FERNANDO
CASTAIC RES.
STA
TEFW
Y.
RESERVOIR
CANY
ON
SPUNKY
CYN. RD.
RD.LAKESMUNZ
RD. LAKE
RESERVOIRDRY CANYON
LAK
E
HUGHES
FORT TEJON
165T
H
RESERVOIRLITTLE ROCK
MOUNTAINS
FOREST
BIG TUJUNGARESERVOIR
HY
.
FWY.
GABRIEL
CRYSTAL
ROCKRD.
RD.
BIG
LAKE
CREEK HY.
PINES
BIG
ANTELOPE
CREST
30T
H
AN
TE
LOP
E
SIE
RR
A
10 T
H
50T
H
UNALAKE
PALMDALE
47T
H
SOM
ST
.E
PALMDALE
RD.AVENUE
AVENUE
P
60T
H PALMDALEAVENUE M
RD.
PEARRESERVOIRHY.
HY. BLOS
ST
. E90T
H
170T
H
BLVD.
O
ST
.E
PEARBLOSSOMHY.
ST
. E
CO
UN
TY
BE
RN
AR
DIN
OS
AN
AVENUE
AVENUE
260T
H
PYRAMID
GO
LDEN
LAKEQUAIL
LOS ANGELES
KERN
.RDV
EN
TUR
A
LANCASTER
ELIZABETH
170T
H
RD.
LAKE
RES. RD.
ELIZABETHLAKE
RES.FAIRMONT
RD.
FAIRMONT
ST
. W
110T
HS
T. W
PINE
ST
. W
LANCASTER
LAKETWEEDY
CANYON
AVENUE ST
.W
AVENUEI V
ALL
EY ST
.E
AVENUED F
WY
.
HY
.
G
J
ST
.E
140T
HS
T.E
COUNTY
E
COUNTY
CO
UN
TY
101605
60
10COVINAWEST
PARKBALDWIN
57
BAR
DIAMOND
GLE
NDORA
71
CORONA
405
FWY
.
ISLA
ND
605
210
405
110
710
210
210
60
170
134
5
10
5
10
ELMONTE
105GATE
SOUTH
LAK
EW
OO
D
DIMAS
5
118
5
14
101
91
GLEN
DA
LE
EN
ES
LOCATION MAP
LOS ANGELES
ST
E
HUGHES
VENTURA
MU
LH
OL
CUT-OFF
CYN.
BREA
GARDENSCUDAHY
BLVD.
MO
NIC
A MANCHESTER BLVD.
BIXBYROLLING HILLS
SLOUGH
HILLS ESTATESESTATESPALOS VERDES ROLLING
N
E A
O C
F I
P A C I
SE
PU
LVE
DA
LAWNDALE
ARTESIA GARDENA
BA
Y
HAWTHORNE
INGLEWOOD
DEL REY
MARIN
A
SEGUNDOEL
SA
N
TORRANCE BEACHREDONDO
PACIFIC
HERMOSA BEACH
HA
RB
OR
LOMITA
SANC
MANHATTAN BEACH
TE
RM
INA
L
HILLFW
Y.COAST
ORANGE
PEDRO BAY
BEACHLONG
HY.
SAN
PARAMOUNT
BE
AC
H
GA
BR
IEL
LA MIRADA
FWY.BELLFLOWER
ARTESIA BLVD.
FWY.
FIRESTONEDOWNEY
BLVD.
BLV
D.
PICO RIVERA
SPRINGSSANTA FE
NORWALK
COMPTON
LYNWOOD
ARTESIA
LON
G
SIGNAL
LAKEWOOD
GARDENSHAWAIIAN
CERRITOSS
ANDIEGO
CARSON
HAC
COUNTY
RD.
AVE. P
HY.
HY.
BE
RN
AR
DIN
O
TUJU
NG
AHILL
LIT
TLE BIG TUJUNGA
CO
UN
TY
FWY.
GLEASON
AVE.
FW
Y.
HOLLYWOOD
HUNTINGTON PARK
GLENDALE
VIR
G
RES.
TO
PAN
GA
CA
NY
ON
COASTPACIFIC
MULHOLLAND
RD
.
CA
NY
ON
MA
LIB
U
RD
.
LAS
RD
. HY.
DE
C
LAND
KER
KAN
AN
RD.
HY.
DUME
KANAN
CONTROL DISTRICT BOUNDARYFLOODLOS ANGELES COUNTY
DESCRIPTION
STREET IMPROVEMENT PLAN10625 COLE RD, WHITTIER, CA 90604
SHEET NO
INDEX TO PROJECT DRAWINGS
R.D. 446
BENCHMARK: Elev.
BM NO. 0Y8229 QUAD 2005
TITLE SHEET
BENCH MARKS226.867
L&BN IN W CB 13 FT N/O BCR @ NW COR LEFFINGWELL RD &STAMLY RD
1 TITLE SHEET2 GENERAL NOTES3 COLE RD
1 4
APN 8226-020-905
MULBERRY DR4
VICINITY MAPSCALE: 1"=1000'
EIMP 2021000146
KEY MAPSCALE: 1" = 200'
MULBERRY DR
CO
LE R
D
TYPICAL SECTION COLE RD.NOT TO SCALE
60'
30' 30'
20'10' 20' 5' 5'
EXISTING A.C. PAVEMENT
EXISTING CURB & GUTTER
L/A L/A
EXISTING A.C. PAVEMENT
EXISTING CURB & GUTTER
EXISTING SIDEWALK
TYPICAL SECTION MULBERRY DR.NOT TO SCALE
100'
50' 50'
40'10'
EXISTING A.C. PAVEMENT
EXISTING CURB & GUTTER
EXISTING A.C. PAVEMENTEXISTING CURB & GUTTER
EXISTING LEFFINGWELL CREEK
EXISTING SIDEWALK
6"
R/WR/W
R/W R/W
C/L
C/L
ENGINEER'S/SURVEYOR'S STATEMENT REGARDING THE PRESENCE OF MONUMENTS WITHIN PROJECTLIMITS
I HEREBY ATTEST THAT I HAVE LOCATED AND REFERENCED ON THESE PLANS THE MONUMENTSEXISTING PRIOR TO CONSTRUCTION TO ENSURE PERPETUATION OF THEIR LOCATION IN ACCORDANCEWITH SECTION 8771 OF THE BUSINESS AND PROFESSIONS CODE. I FURTHER ATTEST THAT I HAVEPERFORMED A RECORD SEARCH AND FIELD INSPECTION TO IDENTIFY EXISTING MONUMENTS; SHALLSET SUFFICIENT CONTROLLING, WITNESS, AND PERMANENT MONUMENTS; AND SHALL FILE THEREQUISITE CORNER OF RECORD OR RECORD OF SURVEY OF THE REFERENCES WITH THE COUNTYSURVEYOR.
ENGINEER/SURVEYOR DATESEAL AND SIGNATURE
REMOVE EXISTING DRIVEWAY ANDCONSTRUCT 4" P.C.C. SIDEWALKON 6" CAB AND 5' GREEN STRIPPER SPPWC 112-2
R/W
REMOVE EXISTING DRIVEWAY AND CONSTRUCT P.C.C. CURB ANDGUTTER TYPE A2-8(250) ON 6" CAB PER SPPWC STD. PLAN 120-2
4" A.C. (C2-PG 64-10) ON8" TRENCH BACKFILL SLURRY
TYPICAL DRIVEWAY CLOSURE - COLE RD.
NOT TO SCALESTA: 00+98.24 TO STA: 01+78.10
REMOVE EXISTING LOADING ZONE ANDCONSTRUCT 8" CURB AND GUTTER WITH4" P.C.C. SIDEWALK ON 6" CAB PERSPPWC 112-2
REMOVE EXISTING DRIVEWAY AND CONSTRUCT P.C.C. CURB ANDGUTTER TYPE A2-8(250) ON 6" CAB PER SPPWC STD. PLAN 120-2
6" A.C. (C2-PG 64-10) ON8" TRENCH SLURRY BACKFILL
TYPICAL LOADING ZONE CLOSURE - MULBERRY DR.
NOT TO SCALESTA: 18+12.17 TO STA: 17+27.38
4.5' 5'GREEN STRIP
CONSTRUCTION NOTESPROTECT IN PLACE EXISTING ITEMJOIN AND MATCH EXISTING PCC CURB, GUTTER, AND/OR SIDEWALK WITH FLUSHTRANSITIONCONSTRUCT 4" PCC SIDEWALK WITH 6" CRUSHED AGGREGATE BASE PER SPPWCSTANDARD PLAN 112-2
CONSTRUCT CURB & GUTTER TYPE A2-8 (200) PER SPPWC STANDARD PLAN 120-2
CONSTRUCT MODIFIED TYPE C DRIVEWAY PER SPPWC STANDARD PLAN 110-2SAWCUT AND REMOVE EXISTING PCC CURB, GUTTER, AND/OR SURFACE ANDBASESAWCUT AND REMOVE EXISTING AC SURFACE AND BASESAWCUT AND REMOVE EXISTING PAVEMENT AND BASE. CONSTRUCT 6" AC (C2-PG64-10) OR EXISTING AC +1" WHICHEVER IS GREATER, ON 8" TRENCH BACKFILLSLURRY (270-E-500)
GRIND AND OVERLAY EXISTING ASPHALT SURFACE 1 1/2" MINIMUMCONSTRUCT 0"-8" PCC (520-C-2500) CURB TRANSITION PER DETAIL "A" ON SHEET 3
CONSTRUCT MODIFIED CASE D TYPE 1 CURB RAMP (NO GROOVE) PER SPPWCSTANDARD PLAN 111-5CONSTRUCT CURB TYPE A1-8 (200) PER SPPWC STANDARD PLAN 120-2
1
2
3
4
5
6
7
8
9
10
11
12
REG
I ST E
REDPROF E S S I ONAL
ENGI N
EER
S TAT E OF CA L I FORN I A
No. C 59118
C I V I L
TRO
Y D A VID MOL AUG
PROJECT ENGINEER DATE EIMP
SHEET OF
LOS ANGELES COUNTY PUBLIC WORKS
ROAD AND GRADING SECTION
BY
BY
DATE
DATE
ASSISTANT DIVISION ENGINEERBY
REVISIONS
DATE
NO. REVISED BY APPROVED BY DATE
RECOMMENDED LAND DEVELOPMENT DIVISION
PH
APPROVED MARK PESTRELLA, DIRECTOR OF PUBLIC WORKS
REVIEWED
ROAD AND GRADING SECTION
TS-RD-DL - 04/2019
DATE: TIME:FILE:$DATE$ $TIME$ $FILEL$
2021000146
LAND SURVEYING PLANNING STORMWATER MANAGEMENT
101 E. REDLANDS BOULEVARDSUITE 146REDLANDS, CA 92373
TEL : 909.792.5969www.EpicRCE.com
CIVIL ENGINEERINGExp. 6-30-2021
SAW
CUT
LINE
REMOVE EXISTINGDRIVEWAY AND REPLACEWITH GREEN STRIP
R/W
EXISTING A.C.PAVEMENT
SAWCUT AND REMOVE EXISTING PAVEMENT AND BASE.CONSTRUCT 6" AC (C2-PG 64-10) OR EXISTING AC +1"WHICHEVER IS GREATER, ON 8" TRENCH BACKFILL SLURRY
REMOVE EXISTING DRIVEWAY AND CONSTRUCT P.C.C. CURB ANDGUTTER TYPE A2-8(200) ON 6" CAB PER SPPWC STD. PLAN 120-2
6" A.C. (C2-PG 64-10) ON8" TRENCH SLURRY BACKFILL
TYPICAL DRIVEWAY CLOSURE - COLE RD.
NOT TO SCALESTA: 04+53.53 TO STA: 05+20.27
PROPOSEDGREEN STRIP
6" 5.5'4'10'
REMOVE EXISTING LOADING ZONEAND REPLACE WITH MODIFIED TYPE CDRIVEWAY PER SPPWC 110-2
1"
2.0%
TYPICAL DRIVEWAY SECTION A-A
NOT TO SCALEMULBERRY DR.
EXISTING P.C.C. CURB
6"
VARIES VARIES
VARIES VARIES
GRIND & OVERLAY EXISTINGASPHALT SURFACE 1 12" MINIMUM
R/W
SHEET 4
SHEE
T 3
2.0% MAX
2.0% MAX
6" A.C. (C2-PG 64-10) ON8" TRENCH SLURRY BACKFILL
9'
C/L20'
SAW
CUT
LINE
EXISTING A.C.PAVEMENT
GRIND & OVERLAY EXISTINGASPHALT SURFACE 1 12" MINIMUM
C/L36.5'
SAWCUT AND REMOVE EXISTING PAVEMENT AND BASE.CONSTRUCT 6" AC (C2-PG 64-10) OR EXISTING AC +1"WHICHEVER IS GREATER, ON 8" TRENCH BACKFILL SLURRY
R/W
C/L20'
SAW
CUT
LINE
EXISTING A.C.PAVEMENT
SAWCUT AND REMOVE EXISTING PAVEMENT AND BASE.CONSTRUCT 4" AC (C2-PG 64-10) OR EXISTING AC +1"WHICHEVER IS GREATER, ON 8" TRENCH BACKFILL SLURRY
GRIND & OVERLAY EXISTINGASPHALT SURFACE 1 12" MINIMUM
EXISTING A.C.PAVEMENT
GRIND & OVERLAY EXISTINGASPHALT SURFACE 1 12" MINIMUM
C/L36.5'
SAWCUT AND REMOVE EXISTING PAVEMENT AND BASE.CONSTRUCT 6" AC (C2-PG 64-10) OR EXISTING AC +1"WHICHEVER IS GREATER, ON 8" TRENCH BACKFILL SLURRY
SAW
CUT
LINE
ORCHARD DALEELEMENTARY SCHOOL
10%
SITE
ORCHARD DALEELEMENTARY SCHOOL
PLS No.
PR
OF E
S S I ON A L L A N D S URV EYOR
STEVE A LEJA
5933
STATE OF CA L I FORN IA
7/13/21
7/13/21
~.~~~~-
~' ~
7/22/2021
07/22/2021
07/22/2021
086401
ROAD STANDARD NOTES1. A ROAD CONSTRUCTION PERMIT SHALL BE OBTAINED AND FEES PAID FOR CONSTRUCTION INSPECTION TOTHE DEPARTMENT OF PUBLIC WORKS (DPW/THE COUNTY) AT THE LAND DEVELOPMENT DIVISION PERMITCOUNTER, 900 SOUTH FREMONT AVENUE, 3RD FLOOR, ALHAMBRA PRIOR TO STARTING WORK. ALLOWTHREE WEEKS FOLLOWING PERMIT APPLICATION SUBMITTAL TO ENSURE ADEQUATE PROCESSING TIMEFOR PERMIT ISSUANCE. FOR QUESTIONS CONTACT LAND DEVELOPMENT DIVISION, ENROACHMENTPERMITS AND INSPECTION SECTION 626 4-58-4920
2. WHEN WORK IS WITHIN A CONTRACT CITY, THE CONTRACTOR SHALL CONTACT THE CITY’S DIRECTOR OFPUBLIC WORKS TO DETERMINE THE LOCATION TO PAY THE INSPECTION FEES.
3. THE CONTRACTOR SHALL CONTACT THE PERMIT OFFICE LISTED ON THE PERMIT APPLICATION TOARRANGE FOR A PRE-CONSTRUCTION MEETING PRIOR TO CONSTRUCTION START.
4. A FLOOD PERMIT SHALL BE OBTAINED FROM DPW, LAND DEVELOPMENT DIVISION AT (626) 458-3129 FORALL STORM DRAIN CONNECTIONS.
5. FOR ALL WORK, SUBJECT TO APPROVAL AND INSPECTION BY CALTRANS OR CITIES, OBTAIN A PERMITFROM THOSE JURISDICTIONS 30 DAYS PRIOR TO CONSTRUCTION WITHIN THEIR RIGHT-OF-WAY.
6. ALL WORK SHALL CONFORM TO THE STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION (SPPWC) ANDTHE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, SUPPLEMENTED WITH THE LOSANGELES COUNTY DEPARTMENT OF PUBLIC WORKS STANDARD PLANS 2000 EDITION. THE LATESTEDITIONS OF THESE MANUALS SHALL BE USED UNLESS OTHERWISE NOTED ON THE PLANS.
7. WORK IN PUBLIC STREETS, ONCE BEGUN, SHALL BE PROSECUTED TO COMPLETION WITHOUT DELAY TOAVOID UNNECESSARY INCONVENIENCE TO ADJACENT PROPERTY OWNERS AND TO THE TRAVELINGPUBLIC. FAILURE TO COMPLY WITH THIS REQUIREMENT IS A VIOLATION OF SECTION 16.06.080 OF THECOUNTY HIGHWAY PERMIT ORDINANCE.
8. THE CONTRACTOR SHALL TAKE ALL NECESSARY AND PROPER PRECAUTIONS TO PROTECT ADJACENTPROPERTIES FROM ALL DAMAGE THAT MAY OCCUR FROM STORM WATER RUNOFF AND/OR DEPOSITION OFDEBRIS RESULTING FROM ANY AND ALL WORK IN CONNECTION WITH ITS WORK.
9. THERE SHALL BE NO ABOVE-GROUND OBSTRUCTION IN ANY PORTION OF THE SIDEWALK EXCEPT WHERETHE WIDTH, EXCLUSIVE OF THE CURB WIDTH, IS 6 FEET OR GREATER.
10. AT THE EARLIEST OPPORTUNITY OR PRIOR TO FORMING SIDEWALKS, THE CONTRACTOR SHALL CONTACTTHE LOCAL POSTAL OFFICE FOR LOCATION APPROVAL AND TYPE OF MAILBOX RECEPTACLES TO BEINSTALLED. MAILBOX RECEPTACLES, WHEN LOCATED BEHIND THE CURB, SHALL NOT BE INSTALLEDWITHIN THE CURVE SECTIONS OF CUL-DE-SAC BULBS AND KNUCKLES.
11. CONSTRUCT WALK RETURNS AND TRANSITIONS PER DPW STANDARD PLAN 1130-1. WALK TRANSITIONSAROUND DRIVEWAYS AND UTILITIES SHALL CONFORM WITH DETAILS SHOWN HEREON.
12. CONSTRUCT RESIDENTIAL DRIVEWAYS (4” PCC ON 6” BASE) PER SPPWC STANDARD PLAN 110-2 UNLESSOTHERWISE SHOWN. PRIOR TO FORMING CURB AND GUTTER, THE CONTRACTOR SHALL CONFER WITHTHE COUNTY INSPECTOR TO SECURE APPROVAL FOR ALL DRIVEWAY LOCATIONS AND WIDTHS.
13. CONSTRUCT STREET NAME SIGNS PER LOCATIONS SHOWN ON PLAN IN ACCORDANCE WITH CURRENTCOUNTY SPECIFICATIONS AND STANDARD PLANS FOR STREET NAME SIGNS. INSTALLATIONS SHALLCONFORM TO “TYPE B” FOR STREETS CLASSIFIED AS RESIDENTIAL AND “TYPE A” FOR STREETS CLASSIFIEDAS ANY OTHER CLASSIFICATION ABOVE RESIDENTIAL. ALL STREET NAME SIGNS AT AN INTERSECTIONSHALL BE OF THE SAME TYPE AND SHALL HAVE ASTM TYPE IX RETRO-REFLECTIVE SHEETING WITH ANANTI-GRAFFITI OVERLAY FILM. CONTACT THE DPW SIGN SHOP AT (626)458-1700 FOR SPECIFICATIONS ANDSTANDARD PLANS. STREET NAME SIGNS SHALL BE POSTED PRIOR TO OCCUPANCY OF BUILDINGS.
14. PROVIDE A STREET LIGHTING SYSTEM APPROVED BY THE STREET LIGHTING SECTION, TRAFFIC ANDLIGHTING DIVISION; AND PROVIDE FOR THE TEMPORARY OPERATIONS OF THE STREET LIGHTING SYSTEM.CONTACT TRAFFIC AND LIGHTING DIVISION AT (626) 300-4726 FOR MORE INFORMATION.
15. THICKNESS OF BASE MATERIALS WILL BE DETERMINED BY CALIFORNIA BEARING RATIO (CBR) SOIL TESTAND ESTABLISHED BY THE DPW MATERIALS LABORATORY. THE APPLICANT’S ENGINEER SHALL REQUEST TESTBY DPW, MATERIALS LABORATORY AT (626) 458-7936 AFTER STREETS HAVE BEEN ROUGH GRADED.PLANS MUST BE REVISED TO SHOW ACTUAL BASE TO BE PLACED.
16. CRUSHED MISCELLANEOUS BASE (CMB) MAY BE USED UNDER CURB, GUTTER, WALKS, AND DRIVEWAYS INLIEU OF CRUSHED AGGREGATE BASE.
17. ANY DISTURBANCE OF LOOP DETECTORS OR SIGNAL EQUIPMENT WILL REQUIRE SIGNAL MODIFICATIONPLANS TO BE SUBMITTED TO TRAFFIC AND LIGHTING DIVISION. THE CONTRACTOR SHALL CONFORM WITHTHE APPROVED PLANS.
18. DRIVEWAYS SHALL NOT ENCROACH IN THE 5 (FIVE) FEET GUTTER PORTION OF LOCAL DEPRESSIONS.
19. PLANT STREET TREES PER SPPWC STANDARD PLAN 518-3 THROUGH 524-2 AS APPLICABLE, PRIOR TOOCCUPANCY OF BUILDINGS. SEE STREET TREE LIST HEREON. MINIMUM SIZE TREES SHALL BE 24’ BOXUNLESS OTHERWISE SPECIFIED HEREON.
20. ALL (NEW) UTILITY LINES SHALL BE UNDERGROUND PER SECTION 21.24.400 OF TITLE 21 OF THE LOSANGELES COUNTY CODE. CONTACT LAND DEVELOPMENT DIVISION ENCROACHMENT PERMITS ANDINSPECTIONS SECTION AT (626) 458-3129 FOR PERMITTING INFORMATION RELATED TO UTILITYINSTALLATIONS WITHIN THE PUBLIC RIGHT OF WAY. NO UTLITY STRUCTURE OR LINE SHALL BE PLACEDWITHIN THE PUBLIC RIGHT OF WAY WITHOUT HAVING VALID PERMITS. UNPERMITTED UTILITIES SHALL BEREMOVED AT CONTRACTOR’S/APPLICANT’S SOLE EXPENSE.
21. NO DRIVEWAYS SHOULD BE LOCATED WITHIN 25 FEET UPSTREAM OF A CATCH BASIN WHEN STREETGRADES IS 6% OR GREATER.
22. RIP RAP NOTES:
A. ROCKS FOR GROUTED RIP RAP SHALL BE GOOD QUALITY BROKEN CONCRETE AND/OR RIVER RUNROCK. THE SMALLEST DIMENSION SHALL NOT BE LESS THAN SIX (6) INCHES NOR GREATER THAN 18INCHES UNLESS OTHERWISE SPECIFIED. THE LARGEST DIMENSION SHALL NOT EXCEED FOUR (4)TIMES THE SMALLEST DIMENSION.
B. THERE SHALL BE A GROUT BED AT LEAST TWO (2) INCHES BENEATH THE FIRST LAYER OF ROCK. ALLTHE VOIDS BETWEEN THE ROCKS SHALL BE FILLED WITH GROUT. MAXIMUM SPACING BETWEENROCKS SHALL BE TWO (2) INCHES.
C. SURFACE ROCKS SHALL BE EMBEDDED FROM 1/2 TO 2/3 OF THEIR MAXIMUM DIMENSION.
23. PIPE BEDDING SHALL BE:
IN ACCORDANCE WITH LOS ANGELES COUNTY ENGINEER CASE A BEDDING PER DPW STANDARD PLAN3092-1 UNLESS OTHERWISE NOTED. THE BEDDING MATERIAL PLACED FROM THE BOTTOM OF THE PIPETO 1 FOOT OVER THE TOP OF THE PIPE SHALL BE SAND, CRUSHED AGGREGATE, OR NATIVEFREE-DRAINING GRANULAR MATERIAL AND SHALL HAVE A SAND EQUIVALENT OF 20 OR GREATER. ORACCORDING TO DPW STANDARD PLAN 3080-1, CASE 3, EXCEPT BELL AND SPIGOT PIPE WHICH SHALL BECASE 2 BEDDING, UNLESS OTHERWISE SHOWN. "W" VALUES SHALL BE AS SPECIFIED ON DPWSTANDARD PLAN 3080-1 FOR CASE 3 BEDDING, NOTES (A), (B), AND (C). IF THE "W" VALUE AT THE TIP OFTHE PIPE IS EXCEEDED, THE BEDDING SHALL BE MODIFIED, AND/OR PIPE OF ADDITIONAL STRENGTHSHALL BE PROVIDED. THE PROPOSED MODIFICATION SHALL BE APPROVED BY THE DEPARTMENT.
24. ALL CONSTRUCTION JOINTS FOR P.C.C. CURBS, GUTTERS, DRIVEWAYS AND SIDEWALKS SHALL BE INACCORDANCE WITH SPPWC STANDARD PLAN NO. 112-2.
25. THE LATEST REVISED PLAN OR DRAWING SHALL BE USED UNLESS OTHERWISE SPECIFICALLY NOTED.
26. REPAIR ANY CURB, GUTTER, SIDEWALK, AND PAVEMENT BROKEN OR DAMAGED DURING CONSTRUCTION
27. A SIGNING AND STRIPING PLAN IS REQUIRED. THE APPLICANT SHALL SUBMIT SIGNING AND STRIPINGPLANS FOR APPROVAL TO TRAFFIC AND LIGHTING DIVISION (IF NOT ALREADY APPROVED) AND SHALLCONFORM WITH THE APPROVED SIGNING AND STRIPING PLAN PRIOR TO THE ACCEPTANCE OF THESTREETS FOR PUBLIC MAINTENANCE. AFTER OBTAINING THE CONSTRUCTION PERMIT, THE APPLICANTSHALL CONTACT OPERATIONAL SERVICES DIVISION AT (626) 458-1700 TO REQUEST THE FABRICATION ANDINSTALLATION OF REQUIRED SIGNAGE PER APPROVED PLANS. THE APPLICANT SHALL DEPOSITAPPROPRIATE FEES WITH LAND DEVELOPMENT DIVISION WHEN APPLYING FOR THE PERMIT TO ALLOWCOMPLETION OF THE NECESSARY WORK.
28. A TRAFFIC CONTROL PLAN MAY BE REQUIRED FOR WORK WITHIN PUBLIC RIGHT OF WAY. PRIOR TOSECURING A CONSTRUCTION OR EXCAVATION PERMIT, THE APPLICANT/CONTRACTOR SHOULD CONTACTLAND DEVELOPMENT DIVISION AT (626) 458-3129 AT THE EARLIEST POSSIBLE OPPORTUNITY TO DETERMINEIF SUCH A PLAN IS REQUIRED BASED ON THE PROPOSED SCOPE OF WORK. IF A TRAFFIC CONTROL PLAN ISDETERMINED TO BE NECESSARY, THE APPLICANT/CONTRACTOR SHALL SUBMIT PLANS TO LANDDEVELOPMENT DIVISION FOR APPROVAL.
29. ALL EXISTING SIGNS AND POSTS LOCATED WITHIN THE PUBLIC RIGHT OF WAY THAT INTERFERE WITHPROPOSED WORK SHALL BE REMOVED PRIOR TO WORK COMMENCING AND REPLACED IN KIND ONCEWORK HAS BEEN COMPLETED. PLEASE CALL OPERATIONAL SERVICES DIVISION AT (626) 458-1700 5 DAYSPRIOR TO COORDINAT
2 4
NOTES
1. EVERY EFFORT SHOULD BE MADE TO ELIMINATE THE DISCHARGE OF NON-STORMWATER FROM THE PROJECT SITE AT ALL TIMES.
2. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIASHEETFLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES, OR WIND.
3. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTEDFROM THE SITE BY THE FORCES OF WIND OR WATER.
4. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TOCONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THEWEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHEDINTO THE DRAINAGE SYSTEM.
5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONSSHALL BE MADE TO RETAIN CONCRETE WASTES ON-SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE.
6. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENTCONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.
7. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCEROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTALDEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS.
8. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WINDAND WATER.
B. THE FOLLOWING BMPs AS OUTLINED IN, BUT NOT LIMITED TO, THE LATEST EDITION OF THE CALIFORNIA BMP HANDBOOK(CONSTRUCTION) OR CALTRANS STORMWATER QUALITY HANDBOOKS (CONSTRUCTION SITE BMP MANUAL), MAY APPLYDURING THE CONSTRUCTION OF THIS PROJECT (ADDITIONAL MEASURES MAY BE REQUIRED IF DEEMED APPROPRIATE BYTHE PROJECT ENGINEER OR THE BUILDING OFFICAL):
EROSION CONTROL
EC1 SCHEDULINGEC2 PRESERVATION OF EXISTING VEGETATIONEC3 HYDRAULIC MULCHEC4 HYDROSEEDINGEC5 SOIL BINDERSEC6 STRAW MULCHEC7 GEOTEXTILES & MATSEC8 WOOD MULCHINGEC9 EARTH DIKES AND DRAINAGE SWALESEC10 VELOCITY DISSIPATION DEVICESEC11 SLOPE DRAINSEC12 STREAMBANK STABILIZATIONEC13 RESERVEDEC14 COMPOST BLANKETSEC15 SOIL PREPARATION\ROUGHENINGEC16 NON-VEGETATED STABILIZATION
TEMPORARY SEDIMENT CONTROL
SE1 SILT FENCESE2 SEDIMENT BASINSE3 SEDIMRNT TRAPSE4 CHECK DAMSE5 FIBER ROLLSSE6 GRAVEL BAG BERMSE7 STREET SWEEPING AND VACUUMINGSE8 SANDBAG BARRIERSE9 STRAW BALE BARRIERSE10 STORM DRAIN INLET PROTECTIONSE11 ACTIVE TREATMENT SYSTEMSSE12 TEMPORARY SILT DIKESE13 COMPOST SOCKS & BERMSSE14 BIOFILTER BAGS
WIND EROSION CONTROL
WE1 WIND EROSION CONTROL
EQUIPMENT TRACKING CONTROL
TC1 STABILIZED CONSTRUCTION ENTRANCE EXITTC2 STABILIZED CONSTRUCTION ROADWAYTC3 ENTRANCE/OUTLET TIRE WASH
NON-STORMWATER MANAGEMENT
NS1 WATER CONSERVATION PRACTICESNS2 DEWATERING OPERATIONSNS3 PAVING AND GRINDING OPERATIONSNS4 TEMPORARY STREAM CROSSINGNS5 CLEAR WATER DIVERSIONNS6 ILLICIT CONNECTION/DISCHARGENS7 POTABLE WATER/IRRIGATIONNS8 VEHICLE AND EQUIPMENT CLEANINGNS9 VEHICLE AND EQUIPMENT FUELINGNS10 VEHICLE AND EQUIPMENT MAINTENANCENS11 PILE DRIVING OPERATIONSNS12 CONCRETE CURINGNS13 CONCRETE FINISHINGNS14 MATERIAL AND EQUIPMENT USENS15 DEMOLITION ADJACENT TO WATERNS16 TEMPORARY BATCH PLANTS
WASTE MANAGEMENT & MATERIAL POLLUTION CONTROL
WM1 MATERIAL DELIVERY AND STORAGEWM2 MATERIAL USEWM3 STOCKPILE MANAGEMENTWM4 SPILL PREVENTION AND CONTROLWM5 SOLID WASTE MANAGEMENTWM6 HAZARDOUS WASTE MANAGEMENTWM7 CONTAMINATION SOIL MANAGEMENTWM8 CONCRETE WASTE MANAGEMENTWM9 SANITARY/SEPTIC WASTE MANAGEMENTWM10 LIQUID WASTE MANAGEMENT
STORMWATER POLLUTION CONTROL REQUIREMENTS FORROAD CONSTRUCTION STORMWATER POLLUTION PLAN NOTES
1. CMB SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 200-2.4 OF THE “GREENBOOK”, STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, 2003EDITION OR LATEST EDITION.
2. PLACE A DEPOSIT WITH GEOTECHNICAL AND MATERIAL ENGINEERING DIVISION (GMED) TO INCLUDE THE CPST OF REVIEWING THE SUBMITTAL AND QUALITY ASSURANCETESTING. CONTACT GMED AT (626) 458-4928 EXTENSION 3687 FOR A COPY OF THE CURRENT COST ESTIMATE WORKSHEET.
3. SUBMIT THE FOLLOWING ITEMS TO GMED FOR REVIEW AND APPROVAL.* ALLOW A MINIMUM OF TWO (2) WORKING DAYS FOR REVIEW OF SUBMITTAL (S). CERTIFICATE OFCOMPLIANCE WILL NOT BE ACCEPTED AS A SUBSTITUTE FOR THESE TESTS.# SOURCE LOCATION OF CMB# CMB GRADATION (ASTM C 131 TEST GRADING)# R-VALUE (CT 301)# SAND EQUIVALENT (SE) (CT 217)# PERCENTAGE WEAR @ 100 AND @ 500 REVOLUTIONS (ASTM C 131)*NOTE: ANY ITEM NOT IN COMPLIANCE WITH SECTION 200-2.4 OF THE GREENBOOK MAY BE RESUBMITTED FOR REVIEW.
4. PRELIMINARY STAMPED APPROVAL FROM GMED WILL BE GIVEN WHEN ALL CMB ITEMS ARE IN COMPLIANCE WITH SECTION 200-2.4 OF THE GREENBOOK.5. SUBMIT A QUQLITY CONTROL (QC) PLAN TO GMED FOR REVIEW AND APPROVAL.
CRUSHED MISCELLANEOUS (CMB) NOTESPRIOR CONSTRUCTION
DURING CONSTRUCTION1. CONTACT GMED AT (626) 458-1707 TO SCHEDULE THE QUALITY ASSURANCE (QA) TESTING OF CMB. PROVIDE A MINIMUM OF 48 HOURS ADVANCE NOTICE.2. FOR EVERY 1,000 TONS OF CMB, A 100 LB SAMPLE SHALL BE OBTAINED AND THE FOLLOWING QUALITY TESTS PERFORMED BY GMED.
# SAND EQUIVALENT (CT 217) AND GRADATION PER SAMPLE# ONE (1) R-VALUE TESTS PER SAMPLE (CT 301)**# PERCENTAGE WEAR AT 100 AND AT 500 REVOLUTIONS (ASTM C131) PER SAMPLE.
3. FOR EVERY 2,500 SQUARE FEET OF CMB, AN IN-SITU DENSITY TEST SHALL BE PERFORMED BY GMED USING THE NUCLEAR GAUGE PER CT 231. PLEASENOTIFY GMED A MINIMUMOF 24 HOUR NOTICE TO SCHEDULE THIS TEST.
4. FINAL APPROVAL IS CONTINGENT UPON THE QA TEST RESULTS PROVIDED BY GMED.**THE R-VALUE REQUIREMENT MAY BE WAIVED PROVIDED THE MATERIAL HAS A SE OF 40 OR MORE.
AFTER CONSTRUCTIONSUBMIT THE RESULTS OF THE QUALITY CONTROL (QC) TEST TO GMED. A NOTIFICATION OF THE QC TEST RESULT APPROVAL SHALL BE PROVIDED TO THECOUNTY INSPECTOR.
REG
I ST E
REDPROF E S S I ONAL
ENGI N
EER
S TAT E OF CA L I FORN I A
No. C 59118
C I V I L
TRO
Y D A VID MOL AUG
PROJECT ENGINEER DATE EIMP
SHEET OF
LOS ANGELES COUNTY PUBLIC WORKS
BYDATE
REVISIONSNO. REVISED BY APPROVED BY DATE
PH
REVIEWED
ROAD AND GRADING SECTION
TS-RD-DL - 04/2019
DATE: TIME:FILE:$DATE$ $TIME$ $FILEL$
2021000146
LAND SURVEYING PLANNING STORMWATER MANAGEMENT
101 E. REDLANDS BOULEVARDSUITE 146REDLANDS, CA 92373
TEL : 909.792.5969www.EpicRCE.com
CIVIL ENGINEERINGExp. 6-30-2021
GENERAL NOTES
7/13/2107-15-21
086401
ENTRY
EXIT
ENTRY
EXIT
ORCHARD DALEELEMENTARY SCHOOL
EXISTING CENTERLINE
EXISTING R/W
EXISTING R/W
SEE DETAIL "B" HEREONSEE DETAIL "A" HEREON
C/L STA MULBERRY DR: 14+10.88 W =C/L STA COLE RD: 00+00.05 N
1+00 2+00 3+00 4+00 5+00
60'
30'
30'
20'
10'
S00°04'06"W
FD SPK&W LA CO DPWPER PWFB 0828 1767 / 1768N:5149.3212' E:10234.4482'
0.5'
EXISTING ACSURFACE
EXISTING CURBAND GUTTER
1
14
EXISTING R/W
EXISTING CENTERLINE
STA:
04+
53.5
3BE
GIN
IMPR
OVEM
ENTS
(01.
58TC
)(0
1.13
GL)
(00.
95FL
)
STA:
05+
20.2
7EN
D IM
PROV
EMEN
TS(0
1.65
TC)
(01.
35GL
)(0
1.12
FL)
22
L4
1'20'
10'
30'
EXISTING WATERVALVE
1
2'
5+00
EXISTINGGUTTER
19
EXISTING PCCSURFACE
1
EXISTINGSIDEWALK
1
EXISTING STREET NAME SIGNCOLE RD & LINDHALL WAY
1
EXISTING ACSURFACE
7EXISTINGCURB
6 EXISTINGCURB
6
EXISTINGSIDEWALK
6REMOVE EXISTING DRIVEWAYAND REPLACE WITH 9.5' GREEN STRIP
EXISTINGCURB
1
8
ORCHARD DALE ELEMENTARY SCHOOL
EXISTINGCURB RAMP
6
COLE RD. EXISTING ACSURFACE
EXISTING CURBAND GUTTER
1
1
EXISTING PCCSIDEWALK
1
EXISTING R/W
4
EXISTING CENTERLINE
2 2
L3
1+00
6
EXISTINGGUTTER
1
20'
1'2'
5.5'
30'98
STA:
0+9
8.24
BEGI
N IM
PROV
EMEN
TS(0
1.29
TC),
(00.
50FL
)
STA:
01+
55.3
4 GU
TTER
EDG
EAN
GLE
PT01
.32T
C, 0
0.65
FL
STA:
01+
83.4
3EN
D IM
PROV
EMEN
TS(0
0.78
GL, 0
0.71
FL)
EXISTINGCURB
6 EXISTINGCURB
REMOVE EXISTING GRAVEL ANDREPLACE WITH GREEN STRIPWHEN CONSTRUCTING SIDEWALK.
EXISTINGMANHOLE
1
ORCHARD DALE ELEMENTARY SCHOOL
GB GB GB
8.33% MAX
STA:
01+
60.4
3 GU
TTER
EDG
EAN
GLE
PT01
.34T
C, 0
0.67
FL
01.5
6TC
/FS
0"CF
STA:
01+
67.4
3 BE
GIN
RAM
P01
.48
TC/F
S 0"
CF
STA:
01+
74.4
3 EN
D RA
MP
01.6
4 TC
, 00.
97FS
8" C
F
01.5
5TC
01.0
5FS
01.5
6TC
01.0
6FS
7'
4'
L7
L8 L9
C3
(01.
08)
FS
(00.
86)
FS
01.47FS
01.39FS
2.0%
2.0%
11
10
10
12
0" CF
3STA:
01+
08.2
401
.20T
C/GB
, 00.
53FL
10'
0.5'
LINE DATA TABLELINE
L1
L2
L3
L4
L5
L7
L8
L9
BEARING
N89° 57' 14.22"W
N89° 56' 23.00"W
S00° 10' 29.91"E
S00° 15' 03.52"W
S89° 56' 22.98"E
N00° 04' 06.26"E
N00° 04' 06.26"E
N00° 04' 06.26"E
DISTANCE
10.00'
84.88'
5.11'
66.61'
42.00'
7.00'
7.00'
3.40'
CURVE DATA TABLECURVE
C1
C2
C3
LENGTH
15.12'
15.12'
15.32'
RADIUS
10.00'
10.00'
20.75'
DELTA
86° 37' 40.38"
86° 37' 38.54"
42° 18' 45.42"
TANGENT
9.43'
9.43'
8.03'
C/L STA MULBERRY DR: 14+10.88 W=C/L STA COLE RD: 00+00.05 N
FD SPK&W LA CO DPWPER PWFB 0828 1767 / 1768N:5149.3212' E:10234.4482'
C/L STA MULBERRY DR: 14+10.88 W=C/L STA COLE RD: 00+00.05 N
FD SPK&W LA CO DPWPER PWFB 0828 1767 / 1768N:5149.3212' E:10234.4482'
COLE RD.
MU
LBER
RY
DR
DETAIL "B"SCALE: 1"=10'
0
SCALE: 1"=40'
40 80 120 160
3 4
COLE RD
AREA OF REMOVAL
AC SURFACE
PCC SURFACE
GRIND AND OVERLAY
DETAIL "A"SCALE: 1"=10'
CONSTRUCTION NOTESPROTECT IN PLACE EXISTING ITEMJOIN AND MATCH EXISTING PCC CURB, GUTTER, AND/OR SIDEWALK WITH FLUSHTRANSITIONCONSTRUCT 4" PCC SIDEWALK WITH 6" CRUSHED AGGREGATE BASE PER SPPWCSTANDARD PLAN 112-2
CONSTRUCT CURB & GUTTER TYPE A2-8 (200) PER SPPWC STANDARD PLAN 120-2
CONSTRUCT MODIFIED TYPE C DRIVEWAY PER SPPWC STANDARD PLAN 110-2SAWCUT AND REMOVE EXISTING PCC CURB, GUTTER, AND/OR SURFACE ANDBASESAWCUT AND REMOVE EXISTING AC SURFACE AND BASESAWCUT AND REMOVE EXISTING PAVEMENT AND BASE. CONSTRUCT 6" AC (C2-PG64-10) OR EXISTING AC +1" WHICHEVER IS GREATER, ON 8" TRENCH BACKFILLSLURRY (270-E-500)
GRIND AND OVERLAY EXISTING ASPHALT SURFACE 1 1/2" MINIMUMCONSTRUCT 0"-8" PCC (520-C-2500) CURB TRANSITION PER DETAIL "A" ON SHEET 3
CONSTRUCT MODIFIED CASE D TYPE 1 CURB RAMP (NO GROOVE) PER SPPWCSTANDARD PLAN 111-5CONSTRUCT CURB TYPE A1-8 (200) PER SPPWC STANDARD PLAN 120-2
1
2
3
4
5
6
7
8
9
10
11
12
MU
LBER
RY
DR
MU
LBER
RY
DR
REG
I ST E
REDPROF E S S I ONAL
ENGI N
EER
S TAT E OF CA L I FORN I A
No. C 59118
C I V I L
TRO
Y D A VID MOL AUG
PROJECT ENGINEER DATE EIMP
SHEET OF
LOS ANGELES COUNTY PUBLIC WORKS
BYDATE
REVISIONSNO. REVISED BY APPROVED BY DATE
PH
REVIEWED
ROAD AND GRADING SECTION
TS-RD-DL - 04/2019
DATE: TIME:FILE:$DATE$ $TIME$ $FILEL$
2021000146
LAND SURVEYING PLANNING STORMWATER MANAGEMENT
101 E. REDLANDS BOULEVARDSUITE 146REDLANDS, CA 92373
TEL : 909.792.5969www.EpicRCE.com
CIVIL ENGINEERINGExp. 6-30-2021
FROM 100' N/O MULBERRY DRIVE TO 500' N/O MULBERRY DRIVE
0
SCALE: 1"=10'
10 20 30 40
0
SCALE: 1"=10'
10 20 30 40
PER STANDARD PLANS FOR PUBLICWORKS CONSTRUCTION 120-2 TYPEA1-8 (200) 8"CF
CURB BUILT TO FULLHEIGHT ENTIRELENGTH OFTRANSITION
VARIABLE HEIGHTCURB FACE PERPLAN
DETAIL "A" 0"-8" CURB TRANSITION
NOT TO SCALE
0" CURBTC/FS PER PLAN
8" CURB UNLESS OTHERWISE NOTEDON PLANTC/FS PER PLAN
ADJACENT FINISHEDSURFACE, 7' TRANSITION.
PCC CURB PER STANDARD PLANSFOR PUBLIC WORKS CONSTRUCTION120-2 TYPE A1-8 (200) 8"CF
CURB BUILT TO FULLHEIGHT ENTIRELENGTH OFTRANSITION
TC/FS P
7/13/21
4 ft
07-15-21
086401
EXIT
EXISTING CENTERLINE
EXISTING R/W
EXISTING R/W
EXISTING R/W
ORCHARD DALEELEMENTARY SCHOOL
50'SEE DETAIL "C" HEREON MULBERRY DR: 14+10.88 W =
COLE RD: 0+00.05 NMULBERRY DR: 16+65.42 W =STAMY RD: 0+00.00 S
50'
15+0016+0017+0018+0019+0020+0021+00
FD SPK&W LA CO DPWPER PWFB 0828-1767/1768N: 5149.3212' E: 10234.4482'
N89°56'30"W
EXIT
EXISTING R/W
EXISTING CURB& GUTTER
EXISTING PCCSIDEWALK
EXISTING CURB& GUTTER
1
1
1
ORCHARD DALEELEMENTARY SCHOOL
EXISTING ACSURFACE
1
MULBERRY DR.
43
3
6
4
50'
9.5'
EXISTING CENTERLINE
2.0%
GB
L1
C1
C2
L2
17+0018+00
4'5.
5'2'
EXISTING LANDSCAPEAREA
1
EXISTING BUILDING
9
8
6
2
6
6
2
STA:
18+
64.2
4BE
GIN
IMPR
OVEM
ENTS
(99.
29 T
C, 9
9.67
FL)
STA:
18+
54.2
4 EC
R99
.40
TC, 9
8.73
FL
STA:
18+
44.2
6 BC
R(9
9.49
TC/F
S 0"
CF)
49.5
' RT
STA:
18+
45.0
799
.41T
C/FS
0" C
F45
.5' R
T
STA: 18+33.26C/L 22' DRIVEWAY
STA:
18+
22.2
6 EC
R(0
0.13
TC, 9
9.63
FS 6
" CF)
49.5
' RT
STA:
18+
21.4
399
.56T
C/FS
0" C
F45
.5' R
T
STA:
18+
12.1
7BC
R 10
' RT
99.6
7TC,
99.
00FL
40'
STA:
17+
27.4
0EN
D IM
PROV
EMEN
TS(0
0.15
TC, 9
9.52
FL)
C/L MULBERRY DR: 14+10.88 W =C/L STAMY RD: 0+00.05 N
1' 2'EXISTING BIKE ROUTEBEGIN SIGN
1
5
EXISTINGCURB
6EXISTING PCCSURFACE
FOR REMOVAL OF LOADING ZONE SEE DETAIL ON SHEET 1
GBGB
STA:
17+
32.4
000
.11T
C, 9
9.44
FL
5
GB
L5
N89°56'30"W
0.5'0.5'
AA
SEE TYPICAL DRIVEWAYSECTION A-A ON SHEET 1
EXISTING PCCSIDEWALK
1
GB
99.55FS
99.42FS
99.96TC98.88FS
00.00TC99.02FS
1"CF
R10'R10'
DEPR
ESS
BACK
OF W
ALK
2"
0-6" CURB TRANSITIONPER ON-SITE PLAN
LINE DATA TABLELINE
L1
L2
L3
L4
L5
L7
L8
L9
BEARING
N89° 57' 14.22"W
N89° 56' 23.00"W
S00° 10' 29.91"E
S00° 15' 03.52"W
S89° 56' 22.98"E
N00° 04' 06.26"E
N00° 04' 06.26"E
N00° 04' 06.26"E
DISTANCE
10.00'
84.88'
5.11'
66.61'
42.00'
7.00'
7.00'
3.40'
CURVE DATA TABLECURVE
C1
C2
C3
LENGTH
15.12'
15.12'
15.32'
RADIUS
10.00'
10.00'
20.75'
DELTA
86° 37' 40.38"
86° 37' 38.54"
42° 18' 45.42"
TANGENT
9.43'
9.43'
8.03'
FD N
OTHI
NGES
TB B
Y TI
ES P
ER P
WFB
082
8-67
8CN:
513
5.93
39' E
: 116
45.2
965'
N89°56'30"W
FD L&T PER PWFB0828-1542/1543N: 5139.3288' E: 8314.9582'
COLE RD.
MULBERRY DR
0
SCALE: 1"=40'
40 80 120 160
STAMY RD.
4 4
AREA OF REMOVAL
AC SURFACE
PCC SURFACE
GRIND AND OVERLAY
CONSTRUCTION NOTESPROTECT IN PLACE EXISTING ITEMJOIN AND MATCH EXISTING PCC CURB, GUTTER, AND/OR SIDEWALK WITH FLUSHTRANSITIONCONSTRUCT 4" PCC SIDEWALK WITH 6" CRUSHED AGGREGATE BASE PER SPPWCSTANDARD PLAN 112-2
CONSTRUCT CURB & GUTTER TYPE A2-8 (200) PER SPPWC STANDARD PLAN 120-2
CONSTRUCT MODIFIED TYPE C DRIVEWAY PER SPPWC STANDARD PLAN 110-2SAWCUT AND REMOVE EXISTING PCC CURB, GUTTER, AND/OR SURFACE ANDBASESAWCUT AND REMOVE EXISTING AC SURFACE AND BASESAWCUT AND REMOVE EXISTING PAVEMENT AND BASE. CONSTRUCT 6" AC (C2-PG64-10) OR EXISTING AC +1" WHICHEVER IS GREATER, ON 8" TRENCH BACKFILLSLURRY (270-E-500)
GRIND AND OVERLAY EXISTING ASPHALT SURFACE 1 1/2" MINIMUMCONSTRUCT 0"-8" PCC (520-C-2500) CURB TRANSITION PER DETAIL "A" ON SHEET 3
CONSTRUCT MODIFIED CASE D TYPE 1 CURB RAMP (NO GROOVE) PER SPPWCSTANDARD PLAN 111-5CONSTRUCT CURB TYPE A1-8 (200) PER SPPWC STANDARD PLAN 120-2
1
2
3
4
5
6
7
8
9
10
11
12
REG
I ST E
REDPROF E S S I ONAL
ENGI N
EER
S TAT E OF CA L I FORN I A
No. C 59118
C I V I L
TRO
Y D A VID MOL AUG
PROJECT ENGINEER DATE EIMP
SHEET OF
LOS ANGELES COUNTY PUBLIC WORKS
BYDATE
REVISIONSNO. REVISED BY APPROVED BY DATE
PH
REVIEWED
ROAD AND GRADING SECTION
TS-RD-DL - 04/2019
DATE: TIME:FILE:$DATE$ $TIME$ $FILEL$
2021000146
LAND SURVEYING PLANNING STORMWATER MANAGEMENT
101 E. REDLANDS BOULEVARDSUITE 146REDLANDS, CA 92373
TEL : 909.792.5969www.EpicRCE.com
CIVIL ENGINEERINGExp. 6-30-2021
MULBERRY DRFROM 300' W/O COLE ROAD TO 500' W/O COLE RD
SCO
TT A
VE.
LIN
DH
ALL
WA
Y
DETAIL "C"SCALE: 1"=10'
0
SCALE: 1"=10'
10 20 30 40
STA
MY
RD
.
CC
MODIFIED TYPE C DRIVEWAY DETAIL MULBERRY DRIVE
7/13/2107-15-21
086401