18181_2

Embed Size (px)

Citation preview

  • 7/28/2019 18181_2

    1/6

    TH E R IG HT SO LU T IO N -

    SO SIM PLE TO SELECT

    INDOOR

    UNITS

    INDOORUNITS

  • 7/28/2019 18181_2

    2/6

    When comfort combines with enhanced

    aesthetics it becomes discreet, ergonomic,economic, efficient and compact.

    Aquasmart links comfort and elegant soft

    lines to create systems that blend inharmoniously with your environment.Carrier indoor units are conceived to beeasily installed on the wall, in false ceilings

    or under-floor voids, with high operatingefficiency and adjustable capacity forincreased performance.

    Once again, Carrier controls and utilisescomfort and aesthetics to optimise yourinstallation. The ideal solution to suit anyapplication, regardless of the architecturaland building requirements.

    AESTHETICS

    COMPLEMENTING

    COMFORT

  • 7/28/2019 18181_2

    3/6

    SO MUCH EASIER TO MATC

    CASSETTE

    Easy installation!

    The 42GW cassette has an ultra-low profile(298 mm), is easy to handle and simple to integrateinto false ceilings. Saving space, weight andinstallation time!

    New air quality, new quality of life!

    The 42GW cassette was designed to work with10% fresh air.

    This facilitates room air changes and enhances airquality. Optional electrostatic and activated-carbonfilters contribute to provide exceptional qualityof life.

    FAN COIL UNIT*

    The new 42N fan coil unit makes installationeven easier.

    Designed to reduce installation time, its features

    include a reinforced hanging system, suitablefor vertical, horizontal and false-ceilinginstallations, a reduced number of accessoriesand enhanced flexibility.

    Reliability and durability were the main designcriteria for the new 42N fan coil unit.To give only one example, it includes a long-lifepleated filter.

    Occupant comfort is our main objective therefore these units are equipped with a newultra-quiet tangential fan, allowing integrationinto any environment.

    42N units are available in seven sizes andwith many different configurations.

    *Available during 2002

    Infrared control available

  • 7/28/2019 18181_2

    4/6

    TO YOUR REQUIREMENTS

    DUCTABLE UNIT

    So compact that it will go anywhere!

    The 42EL Aqualia offers maximum quality witha minimum of easily accessible components.

    Equipped with a fresh air inlet linked to a flow

    switch, it permits controlled intake and renewalof fresh air in accordance with applicableregulations and based on the room function.

    Ultra-quiet operation translates into superiorcomfort.

    Installable in false ceilings or under-floor voids,it is both invisible and inaudible.

    In fact, the 42EL Aqualia is the perfect unionof high-technology and total discretion.

    HIGH-WALL UNIT

    A built-in system that offers maximumdiscretion. This unit can be installed on anywall surface for example over a door above

    the eye-line.

    The 42WH incorporates a cold draught

    prevention system as standard to createan ideal and pleasant atmosphere.

    After a power cut the unit restarts with thesame operating parameters as before no

    need to re-program.

    The 42WH makes your life easier a fully

    equipped back panel allows a hinged accessto water and electrical connections hencesimplifying installation and maintenance.

    Maintenance is further facilitated, as the filtercan be changed by direct access through

    the front panel.

  • 7/28/2019 18181_2

    5/6

    The ideal solution

    Aquasmart provides everything to makeyour life easier.

    Assembly, connection and operation are sosimple - childs play.

    In fact, installation is limited to water andelectrical unit connections and the

    installation of a communications bus.

    Intelligent control and exemplary simplicityoffer global system management that

    combines flexibility and quiet comfort,whilst local occupants retain individualcontrol via the Carrier Room Controller(CRC).

    Significant time-savings, reducedbudgetary risks comfort control is at lastwithin your reach. Assured peace-of-mind.

    SIMPLER COMFORT

    CONTROL

    Use it and love it.

    The powerful and user-friendly selectionprogram has simplified the identification and

    selection of the elements needed. In addition,remote system monitoring significantly reducesintervention and diagnostics time.

    A solution that is designed to enhance yourwork quality and comfort. System optimisationfor unequalled usability. And to optimiseeveryones comfort, the Carrier Room Controller

    (CRC) offers complete individualisation of the airconditioning controls.

    CASSETTE

    FAN COIL

    UNIT

    DUCTABLE UNIT

    HIGH-WALL UNIT

  • 7/28/2019 18181_2

    6/6A member of the United Technologies Corporation family

    DixitJM-

    RCSLyonB353000870

    EUROVENTCERTIFIED PERFORMANCE

    IN

    DO

    O

    RU

    NITTECHN

    ICAL

    DATA

    Order No.: 18181-20-02/2002Supersedes order NO.:Manufacturer reserves the right to changeany product specifications without notice

    Quality Management System Approval

    Carrier actively participates in the Eurovent certificationprogrammes. Eurovent is an independent organisation thattests products and verifies the conformance between test

    results and data published by the manufacturer.Eurovent certification is an important guarantee for consultantsand installers. They can be sure that a product with Euroventcertification will operate in conformance with the specificationsand satisfy customer requirements.All indoor units come with Eurovent certification.

    Cooling conditions: air temperature 27 C db/ 19C wb, entering and leaving water temperature 7C/ 12 C at high fan speed.

    Heating conditions, 2-pipe units: air temperature 20C db, entering w ater temperature 50 C same water flow rate as in cool ing mode, at high fan speed.

    * Heating conditions, 4-pipe units: air temperature 20C db, entering/ leaving water temperature 60/ 70 C same water flow rate as in cool ing mode, at high fan speed.

    42GWC 42GWC 42GWC 42GWC 42GWC 42GWC 42GWD 42GWD 42GWD 42GWD

    42GW 004 008 010 012 016 020 004 008 010 020*

    CASSETTE 42GWE 42GWE 42GWE 42GWE 42GWE 42GWE

    004 008 010 012* 016* 020*

    Total cooling capacity kW 2 ,4 4 4 ,7 5 ,9 8 ,3 1 1 1 ,9 3 ,4 4 9

    Sensible cooling capacity kW 1 ,9 3 3 ,8 4 ,8 6 ,4 8 ,8 1 ,6 3 3 7 ,2

    Heating capacity kW 3 ,8 5 ,5 6 ,6 8 ,5 1 0 ,6 1 4 ,4 1 ,9 4 ,8 5 ,4 7

    Electric heaters ( 4 2 GWE) kW 1 ,5 2 ,5 2 ,5 3 3 3 - - - -Net dim ensions H x L x D m m 2 9 8 x5 7 5 x5 7 5 2 9 8 x8 2 5 x8 2 5 2 9 8 x5 7 5 x5 7 5 2 9 8 x8 2 5 x8 2 5

    Grille dim ensions H x L x D m m 3 0 x7 2 0 x7 2 0 3 0 x9 6 0 x9 6 0 3 0 x7 2 0 x7 2 0 3 0 x9 6 0 x9 6 0

    Power supply V-ph-Hz 2 3 0 -1 -5 0 2 3 0 -1 -5 0 / 4 0 0 -3 -5 0 2 3 0 -1 -5 0

    Cooling conditions: air temperature 27 C db/ 19 C wb, entering and leaving water temperature 7C/ 12 C at high fan speed.

    42EL DUCTABLEUNIT 11 12 23 24

    Total cooling capacity kW 4 ,3 5 ,1 1 0 ,2 1 1 ,6

    Sensible cooling capacity kW 3 ,3 4 ,4 7 ,8 9

    Heating capacity kW 2 ,5 3 5 5 ,6Electric heaters W 2 x5 0 0 3 x5 0 0 2 x1 0 0 0 2 x1 0 0 0

    Air f low ( h/ m / l) l/ s 2 0 4 2 5 4 4 4 2 5 2 6

    Net dim ensions H x L x D m m 2 2 5 x1 0 8 0 x1 0 0 0 3 6 5 x1 1 8 5 x1 0 0 0

    Pow er supply V-ph-Hz 2 3 0 -1 -5 0

    Cooling conditions: air temperature 27 C db/ 19 C wb, entering and leaving water temperature 7C/ 12 C at high fan speed.

    Heating conditions, 2-pipe units: air temperature 20C db, entering w ater temperature 50 C same water flow rate as in cool ing, at high fan speed.

    The data for the connection module correspond to the fully equipped version.

    42WHHIGH-WALL UNIT 42WHC016 42WHC020 42WHC028

    Total cooling capacity kW 1 ,3 5 1 ,6 5 2 ,1

    Sensible cooling capacity kW 1 ,1 5 1 ,3 5 1 ,9 5

    Heating capacity kW 2 ,0 2 ,3 3 ,2

    Electric heaters W --- --- ---Net dim ensions H x L x D m m 2 9 0 / 8 0 0 / 1 4 5 2 9 0 / 8 0 0 / 1 4 5 3 3 7 / 8 0 0 / 1 7 0

    Back panel dim ensions H x L x D m m 2 8 2 / 7 9 0 / 4 5 2 8 2 / 7 9 0 / 4 5 3 2 0 / 7 9 0 / 4 7

    Pow er supply V-ph-Hz 2 3 0 -1 -5 0

    Cooling conditions: air temperature 27 C db/ 19 C wb, entering and leaving water temperature 7C/ 12 C at high fan speed.

    Heating condition: air temperature 20 C db, entering water tem perature 70C same w ater flow rate as in cool ing, at high fan speed.

    * Provisional data at the time of print.(1) Dimensions with Cabinet(2) Dimensions without Cabinet

    42N FAN COIL UNIT* 02 04 05 06 07 10 12

    Total cooling capacity kW 1 ,4 6 2 ,2 4 3 ,0 8 4 ,0 8 4 ,6 4 5 ,7 7 ,2 5

    Sensible cooling capacity kW 1 ,1 2 1 ,8 6 2 ,4 7 3 ,3 1 3 ,7 4 4 ,7 4 6 ,1 0

    Heating capacity kW 2 ,0 7 3 ,2 0 4 ,2 8 5 ,7 8 6 ,4 9 7 ,5 9 9 ,7 9

    Electric heaters ( low/ high) W 5 0 0 / 1 0 0 0 1 0 0 0 / 2 0 0 0 1 5 0 0 / 3 0 0 0

    Net dimensions H x L x D (1 ) mm 6 5 7 / 8 3 0 / 2 2 0 6 5 7 / 1 0 3 0 / 2 2 0 6 5 7 / 1 2 3 0 / 2 2 0 6 5 7 / 1 4 3 0 / 2 2 0

    Dimensions H x L x D(2 ) mm 6 3 2 / 5 6 5 / 2 2 0 6 3 2 / 7 6 5 / 2 2 0 6 3 2 / 9 6 5 / 2 2 0 6 3 2 / 1 1 6 5 / 2 2 0

    Pow er supply V-ph-Hz 2 3 0 -1 -5 0