1
APPLICATION: Power Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference is needed. PLTC OS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable rays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C. CONDUCTORS: • Stranded soft drawn bare copper conductor, per ASTM B3 & B-8 INSULATION: • Polyvinyl Chloride (PVC) insulation SHIELD: • Aluminum polyester foil with 100% coverage and in contact with a tinned copper drain wire JACKET: • Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant COLOR CODE: • Pairs: Black and White Numbered • Triads: Black, White, and Red Numbered STANDARDS: • UL 13 • UL 2250 • NEC Article 727 for ITC • EPA 40 CFR, part 261 16AWG PLTC OS Instrumentation Cables 300V 105°C #2040-05 INSTRUMENTATION 1-800-945-5542 www.PriorityWire.com Part Number Size No. of Pairs No. of Triads Jacket Thickness Overall Diameter Net Weight AWG inches mm inches mm lbs/mft 16-01PRPLTC-OS 16 1 0.035 0.89 0.254 6.45 47 16-02PRPLTC-OS 16 2 0.450 11.43 0.339 8.61 91 16-04PRPLTC-OS 16 4 0.052 1.32 0.464 11.79 142 16-08PRPLTC-OS 16 8 0.060 1.52 0.633 16.08 256 16-12PRPLTC-OS 16 12 0.060 1.52 0.748 19.00 357 16-16PRPLTC-OS 16 16 0.060 1.52 0.844 21.44 454 16-24PRPLTC-OS 16 24 0.072 1.83 1.026 26.06 667 16-36PRPLTC-OS 16 36 0.072 1.83 1.224 31.09 956 16-50PRPLTC-OS 16 50 0.080 2.03 1.437 36.50 1314 16-01TRPLTC-OS 16 1 0.035 0.89 0.267 6.78 58 16-02TRPLTC-OS 16 2 0.052 1.32 0.460 11.68 126 16-04TRPLTC-OS 16 4 0.052 1.32 0.533 13.54 192 16-08TRPLTC-OS 16 8 0.060 1.52 0.713 18.11 352 16-12TRPLTC-OS 16 12 0.060 1.52 0.863 21.92 500 16-16TRPLTC-OS 16 16 0.072 1.83 0.981 24.92 661 16-24TRPLTC-OS 16 24 0.072 1.83 1.212 30.78 954 16-36TRPLTC-OS 16 36 0.080 2.03 1.410 35.81 1349 16-50TRPLTC-OS 16 50 0.090 2.29 1.681 42.70 1923 All values are nominal and subject to correction ©2020 Priority Wire & Cable 03-2020

16AWG PLTC OS Instrumentation Cables ... PLTC OS Instrumentation...16-36TRPLTC-OS 16 36 0.080 2.03 1.410 35.81 1349 16-50TRPLTC-OS 16 50 0.090 2.29 1.681 42.70 1923 All values are

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 16AWG PLTC OS Instrumentation Cables ... PLTC OS Instrumentation...16-36TRPLTC-OS 16 36 0.080 2.03 1.410 35.81 1349 16-50TRPLTC-OS 16 50 0.090 2.29 1.681 42.70 1923 All values are

APPLICATION: Power Limited Tray Cable Instrumentation Cables are suitable for control, instrumentation and process control circuits, where protection against electrostatic interference is needed. PLTC OS Instrumentation Cables are suitable for wet or dry applications, indoor or outdoor locations, installed in cable rays, ducts, aerially or conduits, direct burial and for applications up to 300 volt and temperatures up to 105°C.

CONDUCTORS: • Stranded soft drawn bare copper conductor, per ASTM B3 & B-8

INSULATION: • Polyvinyl Chloride (PVC) insulation

SHIELD: • Aluminum polyester foil with 100% coverage and in contact with a tinned copper drain wire

JACKET: • Polyvinyl Chloride (PVC) jacket, which is water, chemical, sunlight and abrasion resistant

COLOR CODE: • Pairs: Black and White Numbered• Triads: Black, White, and Red Numbered

STANDARDS: • UL 13• UL 2250• NEC Article 727 for ITC• EPA 40 CFR, part 261

16AWG PLTC OS Instrumentation Cables 300V 105°C

#20

40-0

5IN

STRU

MEN

TATI

ON

1-800-945-5542www.PriorityWire.com

Part NumberSize No. of

PairsNo. ofTriads

JacketThickness

OverallDiameter

NetWeight

AWG inches mm inches mm lbs/mft

16-01PRPLTC-OS 16 1 0.035 0.89 0.254 6.45 47

16-02PRPLTC-OS 16 2 0.450 11.43 0.339 8.61 91

16-04PRPLTC-OS 16 4 0.052 1.32 0.464 11.79 142

16-08PRPLTC-OS 16 8 0.060 1.52 0.633 16.08 256

16-12PRPLTC-OS 16 12 0.060 1.52 0.748 19.00 357

16-16PRPLTC-OS 16 16 0.060 1.52 0.844 21.44 454

16-24PRPLTC-OS 16 24 0.072 1.83 1.026 26.06 667

16-36PRPLTC-OS 16 36 0.072 1.83 1.224 31.09 956

16-50PRPLTC-OS 16 50 0.080 2.03 1.437 36.50 1314

16-01TRPLTC-OS 16 1 0.035 0.89 0.267 6.78 58

16-02TRPLTC-OS 16 2 0.052 1.32 0.460 11.68 126

16-04TRPLTC-OS 16 4 0.052 1.32 0.533 13.54 192

16-08TRPLTC-OS 16 8 0.060 1.52 0.713 18.11 352

16-12TRPLTC-OS 16 12 0.060 1.52 0.863 21.92 500

16-16TRPLTC-OS 16 16 0.072 1.83 0.981 24.92 661

16-24TRPLTC-OS 16 24 0.072 1.83 1.212 30.78 954

16-36TRPLTC-OS 16 36 0.080 2.03 1.410 35.81 1349

16-50TRPLTC-OS 16 50 0.090 2.29 1.681 42.70 1923