The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only channel. The DL380 G4 has a second channel for optional duplex backplane support or external tape support. The Smart Array 6i controller provides one of the most cost effective alternatives to software-based RAID in the market today. Designed as an integrated component on the system board on select ProLiant DL and BL servers, the Smart Array 6i controller and 128MB BBWC Enabler bundle provide increased performance and worry-free transportable battery backed write cache data protection for all server internal storage needs, without consuming a PCI slot. Models Models Models Models Smart Array 6i Controller Smart Array 6i Controller Smart Array 6i Controller Smart Array 6i Controller Smart Array 6i Controller N/A Target Environments Target Environments Target Environments Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Non-RAID Non-RAID Non-RAID Current storage operations where, until now, there has not been a perceived need for data protection, security, or performance gains. Software RAID Software RAID Software RAID Software RAID Current storage operations using software RAID where growing data storage requirements demand the robustness, efficiency, and performance increases available with entry-level hardware RAID. The Smart Array The Smart Array The Smart Array The Smart Array Advantage Advantage Advantage Advantage HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP Smart Array family brings an unparalleled return on investment through: Data Compatibility Data Compatibility Data Compatibility Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. Consistent Configuration and Management Tools Consistent Configuration and Management Tools Consistent Configuration and Management Tools Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. Universal Hard Drive Universal Hard Drive Universal Hard Drive Universal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. Pre-Failure Warranty Pre-Failure Warranty Pre-Failure Warranty Pre-Failure Warranty means HP Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation. QuickSpecs HP Smart Array 6i Controller HP Smart Array 6i Controller HP Smart Array 6i Controller HP Smart Array 6i Controller Overview DA - 12030 North America — Version 18 — September 15, 2009 Page 1

12030_na

Embed Size (px)

DESCRIPTION

12030_na

Citation preview

Page 1: 12030_na

The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protectionof OS, applications, and logs. Most models have one internal-only channel. The DL380 G4 has a second channel for optionalduplex backplane support or external tape support. The Smart Array 6i controller provides one of the most cost effective alternativesto software-based RAID in the market today.

Designed as an integrated component on the system board on select ProLiant DL and BL servers, the Smart Array 6i controller and128MB BBWC Enabler bundle provide increased performance and worry-free transportable battery backed write cache dataprotection for all server internal storage needs, without consuming a PCI slot.

    ModelsModelsModelsModelsSmart Array 6i ControllerSmart Array 6i ControllerSmart Array 6i ControllerSmart Array 6i Controller Smart Array 6i Controller N/A

Target EnvironmentsTarget EnvironmentsTarget EnvironmentsTarget EnvironmentsThe Smart Array 6i Controller offers superior investment protection to the following environments:Non-RAIDNon-RAIDNon-RAIDNon-RAID Current storage operations where, until now, there has not been a perceived need for data protection,

security, or performance gains.Software RAIDSoftware RAIDSoftware RAIDSoftware RAID Current storage operations using software RAID where growing data storage requirements demand the

robustness, efficiency, and performance increases available with entry-level hardware RAID.

The Smart ArrayThe Smart ArrayThe Smart ArrayThe Smart ArrayAdvantageAdvantageAdvantageAdvantage

HP's innovative design and integration work of the Smart Array family of products creates customer valuethat is unmatched in the industry. Use of Smart Array products across multiple applications results in amuch lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP SmartArray family brings an unparalleled return on investment through:

Data Compatibility Data Compatibility Data Compatibility Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades anytime needs for higher performance, capacity, and availability increase. Even successive generations ofSmart Array controllers understand the data format of other Smart Array Controllers.

Consistent Configuration and Management ToolsConsistent Configuration and Management ToolsConsistent Configuration and Management ToolsConsistent Configuration and Management Tools. All Smart Array products utilize a standard set ofmanagement and utility software. These tools minimize Total Cost of Ownership (TCO) by reducingtraining requirements and technical expertise necessary to install and maintain the HP server storage.

Universal Hard DriveUniversal Hard DriveUniversal Hard DriveUniversal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storagesystems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy thesedrives to quickly deliver increased storage capacity, migrate data between systems, and easily managespare drives.

Pre-Failure WarrantyPre-Failure WarrantyPre-Failure WarrantyPre-Failure Warranty means HP Insight Manager not only reports when a drive is going to fail but allowsreplacement of failing drives prior to actual failure. For complete details, consult the HP Support Centeror refer to your HP Server documentation.

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Overview

DA - 12030   North America — Version 18 — September 15, 2009 Page 1

Page 2: 12030_na

Key Product FeaturesKey Product FeaturesKey Product FeaturesKey Product FeaturesHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Increased performance over the Smart Array 5i Controller and the Smart Array 5i Plus ControllerTransportable, hardware-based Ultra320 SCSI RAID controller, with 64MB (upgradable to 192MB) of DDR266 memoryMore robust and easier to use than software-based RAIDAvailable standard on the HP ProLiant DL360 G4, HP ProLiant DL360 G4p (SCSI models only), HP ProLiant DL380 G4, HPProLiant DL380 G4 Packaged Clusters, HP ProLiant DL385 (SCSI models only), HP ProLiant DL385 Packaged Cluster, HPProLiant DL580 G3, HP ProLiant BL20p G3, HP ProLiant BL25p, and the HP ProLiant BL45pCompatibility with all Ultra2, Ultra3, and Ultra320 LVD family products32-bit architectureUniversal hot-plug tape drive support and native SCSI pass through for tape backup supportRecovery ROM protects against a ROM image corruption

128MB Battery Backed Write Cache Enabler Option Kit128MB Battery Backed Write Cache Enabler Option Kit128MB Battery Backed Write Cache Enabler Option Kit128MB Battery Backed Write Cache Enabler Option KitBattery backed write cache for increased controller performanceBattery capacity should retain data for 72 hours (3 days) over the battery life expectancy of 3 yearsAvailable as an optional upgrade for the following HP ProLiant servers:

HP ProLiant BL p-Class (HP BladeSystem):HP ProLiant BL20p G3HP ProLiant BL20p G4HP ProLiant BL25pHP ProLiant BL45p

HP ProLiant DL (rack-optimized):HP ProLiant DL360 G4HP ProLiant DL360 G4p (SCSI models only)HP ProLiant DL380 G4HP ProLiant DL380 G4 Packaged ClustersHP ProLiant DL385 (SCSI models only)HP ProLiant DL385 Packaged ClusterHP ProLiant DL580 G3

Option Kit Contents Include:Field installable memory board, battery board and cable (installs on server board)Support software CDUser guideWarranty card

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Overview

DA - 12030   North America — Version 18 — September 15, 2009 Page 2

Page 3: 12030_na

HP Server CompatibilityHP Server CompatibilityHP Server CompatibilityHP Server Compatibility The Smart Array 6i Controller is integrated on the system board of the following servers:HP ProLiant BL p-Class (HP BladeSystem):

HP ProLiant BL20p G3HP ProLiant BL25pHP ProLiant BL45p

HP ProLiant DL (rack-optimized):HP ProLiant DL360 G4HP ProLiant DL360 G4p (SCSI models only)HP ProLiant DL380 G4HP ProLiant DL380 G4 Packaged Cluster with MSA500 G2HP ProLiant DL380 G4 Packaged Cluster with MSA1000HP ProLiant DL385 (SCSI models only)HP ProLiant DL385 Packaged ClusterHP ProLiant DL580 G3

Also available as an optional upgrade is the 128MB Battery Backed Write Cache Enabler Option Kit (PN346914-B21) for the following servers:

HP ProLiant BL p-Class (HP BladeSystem):HP ProLiant BL20p G3HP ProLiant BL20p G4HP ProLiant BL25pHP ProLiant BL45p

HP ProLiant DL (rack-optimized):HP ProLiant DL360 G4HP ProLiant DL360 G4p (SCSI models only)HP ProLiant DL380 G4NOTE: NOTE: NOTE: NOTE: Some models of the HP ProLiant DL380 G4 ship standard with the 128MB BBWCoption kit. Please refer to the HP ProLiant DL380 G4 QuickSpecs for additional details.HP ProLiant DL380 G4 Packaged Cluster with MSA500 G2HP ProLiant DL385 (SCSI models only)HP ProLiant DL385 Packaged ClusterHP ProLiant DL580 G3

NOTE:NOTE:NOTE:NOTE: For up to date Smart Array compatibility and support information, visit:http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Compatibility

DA - 12030   North America — Version 18 — September 15, 2009 Page 3

Page 4: 12030_na

Supported OperatingSupported OperatingSupported OperatingSupported OperatingSystemsSystemsSystemsSystems

Microsoft Windows ServerMicrosoft Windows Server Hyper-VRed Hat Enterprise Linux (RHEL)SUSE Linux Enterprise Server (SLES)Oracle Enterprise Linux (OEL)Solaris 10 for x86/x64 based SystemsVMwareFor more information on HP's Certified and Supported ProLiant Servers for OS and VirtualizationSoftware and latest listing of software drivers available for your server and Smart Array RAID controller,please visit our Support Matrix at: http://www.hp.com/go/ossupportNOTE:NOTE:NOTE:NOTE: For more Linux OS support & certification information, please visit:

ProLiant & BladeSystem Server Linux matrixhttp://h18004.www1.hp.com/products/servers/linux/Integrity & BladeSystem Server Linux matrixhttp://h71028.www7.hp.com/enterprise/cache/321101-0-0-0-121.html

Software SuiteSoftware SuiteSoftware SuiteSoftware Suite All Smart Array products share a common set of configuration, management and diagnostic tools,including Array Configuration Utility XE (ACU-XE), Array Configuration Utility (ACU), Array DiagnosticUtility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training foreach successive generation of product and takes much of the guesswork out of troubleshooting fieldproblems. These tools lower the total cost of ownership by reducing training and technical expertisenecessary to install and maintain the HP server storage.

Insight ManagerInsight ManagerInsight ManagerInsight Manager Powerful server and server options/storage manager toolMonitors over 1200 server parametersConfiguration/Diagnostic UtilitiesHP Array Configuration Utility (ACU)Powerful Web based configuration utility for all Smart Array controllersProvides a graphical view of HP drive array configurationsAllows for management of multiple arrays over a secure internet connection from anywhere in theworldEasy to use Wizards for configurationRuns online on Windows NT v4.0, Windows 2000, Windows Server 2003, and NetWareHP Options ROM Configuration for Arrays (ORCA)Rapid configuration during initial install of the OSHP Array Diagnostic Utility (ADU)Powerful diagnostic utility for all Smart Array controllers

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Compatibility

DA - 12030   North America — Version 18 — September 15, 2009 Page 4

Page 5: 12030_na

Data CompatibilityData CompatibilityData CompatibilityData Compatibility Data compatibility among all models of Smart Array Controllers means customers can instantly upgradetheir Smart Array products to get to higher performance, capacity and availability. Unlike competitiveproducts, successive generations of Smart Array products understand the data format of other SmartArray controllers, providing investment protection for your HP storage solution.

AvailabilityAvailabilityAvailabilityAvailability Provides increased server uptime by providing advanced storage functionality:  Online RAID Level Migration (between any RAID level)

Online Capacity ExpansionLogical Drive Capacity ExtensionGlobal Online SparePre-Failure Warranty

Fault PreventionFault PreventionFault PreventionFault Prevention The following features offer detection of possible failures before they occur, allowing preventive action tobe taken:

  S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at Compaq detectspossible hard disk failure before it occurs, allowing replacement of the component before failureoccurs.Drive Parameter Tracking monitor's drive operational parameters, predicting failure and notifyingthe administrator.Dynamic Sector Repairing continually performs background surface scans on the hard disk drivesduring inactive periods and automatically re-maps bad sectors, ensuring data integrity.Environment Tracking for External Storage System monitors

Fault ToleranceFault ToleranceFault ToleranceFault Tolerance Keeps data available and server running while a failed drive is being replaced; several fault toleranceconfigurations are supported including:

  Distributed Data GuardingDistributed Data GuardingDistributed Data GuardingDistributed Data Guarding (RAID 5): This allocates parity data across multiple drives and allowssimultaneous write operations. It is recommended for up to 14 hard drives.Drive MirroringDrive MirroringDrive MirroringDrive Mirroring (RAID 1, 1+0): This allocates half of the drive array to data and the other half tomirrored data, providing two copies of every file. It is a high-performance RAID.

Fault RecoveryFault RecoveryFault RecoveryFault Recovery Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure  Recovery ROMRecovery ROMRecovery ROMRecovery ROM: This feature provides a unique redundancy feature that protects from a ROM

image corruption. A new version of firmware can be flashed to the ROM while the controllermaintains the last known working version of firmware. If the firmware becomes corrupt, thecontroller will revert back to the previous version of firmware and continue operating. This reducesrisks associated with flashing firmware to the controller.On-Line SparesOn-Line SparesOn-Line SparesOn-Line Spares: Up to two spare drives can be assigned prior to drive failure. If a drive failureoccurs, recovery begins using an On-Line Spare and data is reconstructed automatically.

  NOTE:NOTE:NOTE:NOTE: On-Line Spares can only be used with RAID level 1, 1+0, and 5.

Ease of UseEase of UseEase of UseEase of Use Consistency and Upgradeability make the Smart Array family unique in the industry:  GUI based configuration, management and diagnostic software tools

Common data format between generations of productsData migration between servers and external storage enclosures

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Product Highlights

DA - 12030   North America — Version 18 — September 15, 2009 Page 5

Page 6: 12030_na

WarrantyWarrantyWarrantyWarranty Maximum:Maximum:Maximum:Maximum: The remaining warranty of the ProLiant server in which it is installed (to a maximumthree-year, limited warranty)Minimum:Minimum:Minimum:Minimum: One-year, on-site limited warranty

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Product Highlights

DA - 12030   North America — Version 18 — September 15, 2009 Page 6

Page 7: 12030_na

NOTE:NOTE:NOTE:NOTE: The following is a list of related options. Some may be discontinued.

Optional UpgradesOptional UpgradesOptional UpgradesOptional Upgrades 128MB Battery Backed Write Cache Enabler Option Kit 346914-B21

Hard DrivesHard DrivesHard DrivesHard Drives Ultra320 Universal Drives - Hot PlugUltra320 Universal Drives - Hot PlugUltra320 Universal Drives - Hot PlugUltra320 Universal Drives - Hot Plug  

HP 300GB U320 10K Universal HDD 350964-B22

HP 146GB U320 10K Universal HDD 286716-B22

HP 72GB U320 10K Universal HDD 286714-B22

HP 300GB U320 15K Universal HDD 411089-B22

HP 146GB U320 15K Universal HDD 347708-B22

HP 72GB U320 15K Universal HDD 286778-B22

HP 36GB U320 15K Universal HDD 286776-B22

NOTE:NOTE:NOTE:NOTE: For complete compatibility information, refer to the SCSI Hard DriveCompatibility table located at:http://www.compaq.com/products/servers/proliantstorage/drives-enclosures/docs/index.html

 

Hot Plug Tape DrivesHot Plug Tape DrivesHot Plug Tape DrivesHot Plug Tape Drives HP StorageWorks DAT 40 SCSI Hot-plug Tape Drive (Carbon) Q1546A

HP StorageWorks DAT 72 SCSI Hot-plug Tape Drive (Carbon) Q1529A

External Tape DrivesExternal Tape DrivesExternal Tape DrivesExternal Tape Drives HP StorageWorks DAT 40 SCSI External Tape Drive (Carbon) C5687D

HP StorageWorks DAT 72 SCSI External Tape Drive (Carbon) Q1523B

HP StorageWorks DLT VS160 External Tape Drive (Carbon) A7570B

HP StorageWorks SDLT 600 External Tape Drive (Carbon) A7519B

HP StorageWorks SDLT 600 External Tape Drive (Carbon) A7520B

Storage EnclosuresStorage EnclosuresStorage EnclosuresStorage Enclosures HP StorageWorks Modular Smart Array 20NOTE:NOTE:NOTE:NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,redundant power supplies.

335921-B21

HP StorageWorks Modular Smart Array 20 Starter KitNOTE:NOTE:NOTE:NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,redundant power supplies. Includes Smart Array 6402/128 Controller.

366172-B21

HP StorageWorks Modular Smart Array 30 SBNOTE:NOTE:NOTE:NOTE: Rack-mountable 14 drive enclosure with single bus, redundant powersupplies.

302969-B21

HP StorageWorks Modular Smart Array 30 DBNOTE:NOTE:NOTE:NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies.

302970-B21

HP StorageWorks Modular Smart Array 500 Generation 2 335880-B21

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Related Options

DA - 12030   North America — Version 18 — September 15, 2009 Page 7

Page 8: 12030_na

Related Smart ArrayRelated Smart ArrayRelated Smart ArrayRelated Smart ArrayProductsProductsProductsProducts

Smart Array 6402/128 Controller 273915-B21

Smart Array 6404/256 Controller 273914-B21

Smart Array 642 Controller 291967-B21

128-MB BBWC (Battery-Backed Write Cache) EnablerNOTE:NOTE:NOTE:NOTE: This 128MB BBWC supports the Smart Array 642 Controller.

351580-B21

64-MB BBWC (Battery-Backed Write Cache) EnablerNOTE:NOTE:NOTE:NOTE: This 128MB BBWC supports the Smart Array 642 Controller.

291969-B21

64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 268351-B21

Ultra320 Expansion Module for SA-6402 273911-B21

64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS 284688-B21

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Related Options

DA - 12030   North America — Version 18 — September 15, 2009 Page 8

Page 9: 12030_na

ArchitectureArchitectureArchitectureArchitecture ProtocolProtocolProtocolProtocol Ultra320 SCSI

ProcessorProcessorProcessorProcessor 405 Power PC

XOR engineXOR engineXOR engineXOR engine Hardware-based XOR calculations for RAID 5

Electrical interfaceElectrical interfaceElectrical interfaceElectrical interface Low Voltage Differential (LVD)

Total SCSI ChannelsTotal SCSI ChannelsTotal SCSI ChannelsTotal SCSI Channels 2 (Depending upon server Model)

SCSI Port ConnectorsSCSI Port ConnectorsSCSI Port ConnectorsSCSI Port Connectors 68-pin wide SCSI connector

MemoryMemoryMemoryMemory DDR 266MHz CL2, 64MB of DDR SDRAM used for code, transfer buffers,and read cache comes standard. Upgradeable to 192MB with 128MBBBWC Option kit.

Peak transfer ratePeak transfer ratePeak transfer ratePeak transfer rate 320 MB/s per SCSI channel

Logical Drives SupportedLogical Drives SupportedLogical Drives SupportedLogical Drives Supported Supports up to 32 RAID volumes

Software UpgradeableSoftware UpgradeableSoftware UpgradeableSoftware UpgradeableFirmwareFirmwareFirmwareFirmware

Recovery ROM can be flashed using HP management tools.

RAID SupportRAID SupportRAID SupportRAID Support RAID 5 (Distributed Data Guarding)

RAID 1+0 (Striping and Mirroring)

RAID 1 (Mirroring)

RAID 0 (Stripping)

Disk Drive and EnclosureDisk Drive and EnclosureDisk Drive and EnclosureDisk Drive and EnclosureProtocol SupportProtocol SupportProtocol SupportProtocol Support

Ultra320, Ultra3, Ultra2

Environment-friendlyEnvironment-friendlyEnvironment-friendlyEnvironment-friendlyProducts and ApproachProducts and ApproachProducts and ApproachProducts and Approach

End-of-life ManagementEnd-of-life ManagementEnd-of-life ManagementEnd-of-life Managementand Recyclingand Recyclingand Recyclingand Recycling

Hewlett-Packard offers end-of-life HP product return, trade-in, and recyclingprograms in many geographic areas. For trade-in information, please go tohttp://www.hp.com/go/green. To recycle your product, please go to:http://www.hp.com/go/green or contact your nearest HP sales office.Products returned to HP will be recycled, recovered or disposed of in aresponsible manner.

The EU WEEE directive (2002/95/EC) requires manufacturers to providetreatment information for each product type for use by treatment facilities.This information (product disassembly instructions) is posted on the HewlettPackard web site at: http://www.hp.com/go/green. These instructions may beused by recyclers and other WEEE treatment facilities as well as HP OEMcustomers who integrate and re-sell HP equipment.

© Copyright 2009 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. Theonly warranties for HP products and services are set forth in the express warranty statements accompanying such products andservices. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorialerrors or omissions contained herein.

For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.

QuickSpecs HP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i ControllerHP Smart Array 6i Controller

Technical Specifications

DA - 12030   North America — Version 18 — September 15, 2009 Page 9