WiMAX Routine Maintenance and
Troubleshooting
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
2/26
Contents
Routine Maintenance
Troubleshooting
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
3/26
Routine Maintenance
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
4/26
Daily and Weekly Maintenance Items
Data Backup and Restoration
Equipment Running Environment Inspection
Board Maintenance Alarm System Maintenance
Log Inspection
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
5/26
Monthly/Quarterly Maintenance Items
Cabinet Maintenance
Data Correctness Inspection
Spare Part Inspection
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
6/26
Half-yearly /Annual Maintenance Items
Equipment Cable Maintenance
Grounding and Lightning Inspection
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
7/26
Contents
Routine Maintenance
Troubleshooting
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
8/26
Fault Acquiring
Alarms
Service observation
Performance statistics User complaints
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
9/26
Fault Location Analysis
Intra network, Inter network
External equipment (power supply, transmission
and switch) System, single BS, some BSs fault, global faults,
system parameter
Software and hardware
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
10/26
Common Troubleshooting Methodologies
Exclusion Method
Trial Method
Analogy Method Reasoning Method
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
11/26
Common Maintenance Methods
Fault Symptom Analysis Observing Indicators
Alarm and Log Analysis
Service Analysis Test with Instruments and Meters
Replacement Method
Service test and Drive Test
Unplugging/Plugging Method
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
12/26
Typical Fault Analysis
Cause Analysis of Low FTP Download Rate Check AAA and confirm whether the maximum rate of user
profile configuration is adequate.
Check whether the segment subcarrier is configured according to5M\10M full subcarrier.
After the traffic flow has been established, check whether the
service type and the maximum rate accord with those of AAA. Check the UL/DL CINR and RSSI by using the NPT and confirm
whether interference exists there.
Check whether the switch connected in the middle link is limitedon the port rate.
Check whether the transmission link is limited. Check whether the Ethernet cables connected the server, switch
and BS are proper.
Check whether the Receiver Buffer and Sent Buffer of the FTPserver are limited.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
13/26
Typical Faults in RRU (1)
Checking Approach to RRU Malfunction
RRU version information: CPU, FPGA, BOOT and
EPLD of the WPTP board as well as MCU and BOOT
of the WDPA board Alarm information: Alarm Description, Reason Code
Description and Append Information
Board diagnosis information: WPTR and WDPA
diagnosis information RF runtime data observation information
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
14/26
Typical Faults in RRU (2)
No RRU Detected
OMC Alarm: No WTRX detected and No WDPA detected; Cause Analysis :
The fiber between RRU and BBU is broken, damaged or of poor quality. The fiber and optical modules between RRU and BBU are in poor contact or
mismatched. The versions of RRU, BBU and OMC are mismatched. The fixed Tx and Rx connectors of fiber are installed respectively in an opposite
position. The RRU is not powered on. Internal malfunctions occur in the RRU.
Troubleshooting : Check the connection condition of fiber. Check and replace the fiber and optical modules between RRU and BBU. Update the RRU version on the NE to make the versions of RRU,BBU and OMC
matching. Observe whether the SD on the PHY board is constantly on. For the Rx and Tx connectors oppositely placed, exchange their locations at the
BBU. Check whether the -48 V power of RRU is normal and the -48 V power connector
is properly connected; Replace RRU.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
15/26
Typical Faults in RRU (3)
No WDPA Detected
OMC Alarm: No WDPA detected;
Cause Analysis :
The WDPA version is mismatched.
The power connector of the WDPA module is in poor contact, causing thatthe WDPA is not powered on.
The control cable between the WDPA and WPTR modules is improperlyconnected, causing that the communication between them is abnormal.
Troubleshooting :
Check whether the WDPA version matches the WPTR version.
Reset the WDPA module on the OMC.
Open the RRU to check whether the power connector of the WDPA module
and the control-cable connector between the WDPA and WPTR modules areconnected well.
Not recommended. Its better
to be opened by ZTE
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
16/26
Typical Faults in RRU (4) No WDPA Detected
OMC Alarm: The PA is abnormal, and The PA Channel 0/1 VSWR isabnormal and The PA Channel 0/1 is closed.
Cause Analysis :
The antenna and feeder corresponding to the channels is not connected well.
The frequency range of DL signals exceeds that of the duplexers RFE.
Troubleshooting :
Use sitemaster to test the real VSWR of the antenna and feeder system andmake sure the VSWR less than 1.5.
Check whether the connectors of the antenna and feeder are screwed downand the shield layer near to the feeders connector is grounded well.
To adjust the frequency range of the DL signals to that of the duplexers RFE,
modify the center frequency of the DL signals on the OMC.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
17/26
Typical Faults in RRU (5) WDPA-Disabled Alarm
OMC Alarm: The PA is abnormal, and The PA Channel 0/1 is closed
Cause Analysis : The VSWR alarm results in the WDPA-disabled alarm.
The broken link of the R6 interface on the BBU results in the WDPA-disabledalarm. The alarms of two channels simultaneously closed.
The abnormal GPS clock on the BBU also results in the WDPA disabledalarm. The alarms of two channels simultaneously closed are created.
The WDPA module is manually disabled
Troubleshooting : First view the append information to locate the detailed alarm cause.
For the WDPA-disabled alarm caused by the VSWR alarm, refer to thesolution of WDPA VSWR Alarm and Closed.
For the WDPA-disabled alarm caused by the broken link of the R6 interface,
perform the Ping command to check the link state from MPXM to AGW. TheWDPA is automatically enabled after the R6 interface recovers.
For the WDPA-disabled alarm caused by the abnormal GPS clock, checkwhether the TFM board and GPS receiver work normally.
For the WDPA disabled manually, enable the WDPA according to yourrequirement (In Alarm Management, set the WDPA to the Enable state).
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
18/26
Typical Faults in RRU (6)
WDPA Hardware Failure Alarm
OMC Alarm: The PA is abnormal, and The PA Channel 0/1 is with ahardware failure Cause Analysis :
The alarm may be caused by the poor contact of the control cable betweenWDPA and WPTR.
Troubleshooting : False alarms may persist in the old version; update the old version to
V.3.32.00P02 and then check whether the alarm genuinely occurs. Open the RRU to check the connection of the control cables connectors
between WDPA and WPTR. Or extract and insert the connectors. (NotRecommended)
Replace the RRU.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
19/26
Typical Faults in RRU (7) RRU Auto-calibration Failure Alarm
OMC Alarm: RRU auto calibration failed, and Tx0/Tx1 auto calibration
failed Cause Analysis :
WDPA Disabled Forward Link Abnormal
Troubleshooting : For the auto calibration failure caused by the disabled WDPA, refer to the
solution of the WDPA-disabled alarm. Set the WDPA to the Enable state andthen manually originate the calibration flow.
For the auto calibration failure caused by the abnormal forward link, open theRRU to check the RF cable connection between the WPTRs RF output andthe WDPAs RF input.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
20/26
Typical Faults in RRU (8) Low Reverse-link RSSI Alarm
OMC Alarm: Reverse link RSSI is low, and RX0/ RX1/ RX2/ RX3RSSI low
Cause Analysis :
For the alarm, it is recommended to observe the correspondingRSSI values in the RF Runtime Data Observation window.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
21/26
Typical Faults in RRU (9)
Low RRU Forward-Power Alarm
OMC Alarm: RRU forward power is low, and Tx0/Tx1 power is
low
Cause Analysis :
The WDPA module is disabled.
The WDPA module is faulty in hardware.
The RRU auto-calibration fails.
The baseband power is low.
Troubleshooting :
Refer to the solution of WDPA-closed alarm, WDPA hardware
failure alarm and RRU auto-calibration failure alarm.
For the alarm caused by the low baseband power, first force to reset
the WBPM board. If the reset is invalid, replace the WBPM board.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
22/26
Typical Faults in RRU (10) Inconsistent Configuration of RRU Board Type
OMC Alarm: The board type is inconsistent with that configured on OMC. Cause Analysis :
The PTR type configured on the OMC is inconsistent with that configured on the RRU.
Troubleshooting :
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
23/26
Typical Faults in RRU (11) Antenna Ability Checking Error
OMC Alarm: RRU antenna ability parameter checking error.
Cause Analysis : The antenna mode configured on the OMC is beyond the antenna ability actually
supported by the RRU.
Troubleshooting : In the Configuration Management window, modify the number of Rx/Tx antennas of the
segment to the antenna ability supported by the RRU.
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
24/26
Typical Faults in RRU (12) RRU Parameter Configuration Failed
OMC Alarm: RRU parameter configuration failed, and the configurationdata error
Cause Analysis : The configuration failure alarm results in the RRU power-on failure. Generally,
the RRU is reset after 6 to 7 minutes.
Modify the frequency rangeconfigured on the OMC intothe supported range.
The error is caused by themismatching RRU logicversion
The radio parameter errorresults in the read failure
8/3/2019 12 WiMAX_T09_E3_WiMAX Routine Maintenance and Troubleshooting-26
25/26
Capture Guide of On-site Fault LocationInformation
Configuration Data NE Running Version Information
Alarm Information
OMC Log Board Diagnosis Information
Running Information Observation
Network Performance Test