Upload
vishal-kain
View
234
Download
10
Tags:
Embed Size (px)
DESCRIPTION
LTE_Connected Mode Mobility
Citation preview
RA4121BEN40GLA0
Connected Mode Mobility
1
RA4121BEN40GLA0
Connected Mode Mobility
4
RA4121BEN40GLA0
Connected Mode Mobility
5
RA4121BEN40GLA0
Connected Mode Mobility
6
RA4121BEN40GLA0
Connected Mode Mobility
7
RA4121BEN40GLA0
Connected Mode Mobility
8
RA4121BEN40GLA0
Connected Mode Mobility
9
RA4121BEN40GLA0
Connected Mode Mobility
10
RA4121BEN40GLA0
Connected Mode Mobility
11
RA4121BEN40GLA0
Connected Mode Mobility
12
RA4121BEN40GLA0
Connected Mode Mobility
13
RA4121BEN40GLA0
Connected Mode Mobility
14
RA4121BEN40GLA0
Connected Mode Mobility
15
RA4121BEN40GLA0
Connected Mode Mobility
16
RA4121BEN40GLA0
Connected Mode Mobility
17
RA4121BEN40GLA0
Connected Mode Mobility
18
RA4121BEN40GLA0
Connected Mode Mobility
19
RA4121BEN40GLA0
Connected Mode Mobility
20
RA4121BEN40GLA0
Connected Mode Mobility
21
RA4121BEN40GLA0
Connected Mode Mobility
22
RA4121BEN40GLA0
Connected Mode Mobility
23
RA4121BEN40GLA0
Connected Mode Mobility
24
RA4121BEN40GLA0
Connected Mode Mobility
25
In order to achieve Lossless HOs packets are forwarded from the source to the target.
Depending on each bearer's QoS profile, the eNodeB shall decide whether data forwarding should be applied to it during the handover or not.
The GTP-U message End Marker is used for ever EPS bearer which is subject to a HO.
The End Marker is an indication of the last DL T-PDU (i.e. user data SDU) to source eNB is expected from the EPC.
The end marker is a special GTP-U PDU which carries no data.
RA4121BEN40GLA0
Connected Mode Mobility
26
RA4121BEN40GLA0
Connected Mode Mobility
27
RA4121BEN40GLA0
Connected Mode Mobility
28
RA4121BEN40GLA0
Connected Mode Mobility
29
RA4121BEN40GLA0
Connected Mode Mobility
30
RA4121BEN40GLA0
Connected Mode Mobility
31
RA4121BEN40GLA0
Connected Mode Mobility
32
RA4121BEN40GLA0
Connected Mode Mobility
33
Load Supervision and Exchange DL GBR and DL nGBR cell load is periodically measured
and exchanged between cells of the same eNB
Upon measuring cell load, the cell evaluates load to determine whether to stay, enter or exit Active LB state
Candidate UE Selection for measurement solicitation UEs which switch from Idle to Connected states are
considered candidates for measurement solicitation
Triggered HOs eventually reduces load for the highly-loaded cells, since already connected UEs will not be offloaded
Special treatment for QCI1 bearers Depending on iFLBBearCheckTimer, UE which
establishes QCI1 bearers may be removed from candidate UEs
Measurement Solicitation For each candidate UE, if serving eNB is highly loaded,
A4 measurements of different frequency neighbor cells is activated
RSRP and RSRQ measurements from received A4 reports are post-processed to select best target cell for UE offloading
iF-LB Execution Normal handover procedure to offload candidates UEs to
selected target cells
33
RA4121BEN40GLA0
Connected Mode Mobility
34
iFLBLoadFilCoeff hard coded parameter non modifiable
RA4121BEN40GLA0
Connected Mode Mobility
35
RA4121BEN40GLA0
Connected Mode Mobility
36
Available Capacity(AC) is taken by normalizing GBR/nGBR load by the configurable GBR/nGBR target load (iFLBTargetLoadGBRDL and iFLBTargetLoadNonGBRDL, respectively)
The AC values are then exchanged between cells of the same eNB periodically
RA4121BEN40GLA0
Connected Mode Mobility
37
In each cell, whenever new load measurements are calculated (LoadGBR,DL,LoadnGBR,DL), the cell load is evaluated
The calculated load measurements are evaluated against load thresholds (target and high load thresholds) to determine load status of the cell
Enter Active iF-LB State GBR OR nGBR load measurement exceed the high-load thresholds
Leave Active iF-LB StateGBR AND nGBR load measurement are below the target load thresholds
Difference between target load and high load thresholds provides hysteresis to prevent ping-pong between iF-LB state transitions
RA4121BEN40GLA0
Connected Mode Mobility
38
*Note: depending on settings for iFLBBearCheckTimer, condition 3 may be excluded
Feature Group Indicator
Defines which features are supported by UE.
BIT13 Inter-frequency Handover
BIT14 A4 and A5 measurements/reporting
BIT25 interfrequency measurement and reporting in connected mode.
reportTimerIFLBA4 - hard coded -non modifiable
RA4121BEN40GLA0
Connected Mode Mobility
39
A4 Configuration hard-coded and NOT configurable
Reported cells would be post-processed to remove cells with insufficient RSRP and/or RSRQ.