Benjamin T. A. Chang (PolyLab LLC Houston, Texas) Ole Øystein Knudsen (SINTEF Materials and Chemistry, Norway) Dennis Wong, Jiri Holub (ShawCor Toronto, Ontario, Canada) Amal Al-Borno (Charter Coating Service (2000) Ltd. Calgary, Canada) J. Alan Kehr (3M Austin Center Austin, TX) Critical Evaluation of International Cathodic Disbondment Test Methods

111873-423012.critical

Embed Size (px)

DESCRIPTION

111873-423012.critical

Citation preview

  • Benjamin T. A. Chang (PolyLab LLC Houston, Texas)

    Ole ystein Knudsen (SINTEF Materials and Chemistry, Norway)

    Dennis Wong, Jiri Holub (ShawCor Toronto, Ontario, Canada)

    Amal Al-Borno (Charter Coating Service (2000) Ltd. Calgary, Canada)

    J. Alan Kehr (3M Austin Center Austin, TX)

    Critical Evaluation of International Cathodic Disbondment Test Methods

  • Pipe laying is often not conducted under the most ideal of conditions

  • pipe-to-soil

    Voltage meter

    With attached

    Reference cell

  • Cathodic Disbondment (CD) resistance is always on the top of the coating property list required by end users.

    At least 22 International and national standard test methods are available that evaluate the resistance to CD

    There is no universal agreement on which standard to use

    Test parameters vary over a wide range among the various test standards

  • Review of Selected CDT Standard Methods

    Notes: 1. Selection means multiple choices. 2. Triple salt solution is 1%/1%/1% of NaCl/Na2CO3/Na2SO4.

    Standard Voltage

    [V] Temperature

    [C] Solution

    [aqueous] Duration

    [days]

    CSA Z-245 1.5 or 3.5 V Selection 3 % NaCl Selection

    ASTM G8 1.5 RT Triple salt Selection

    ASTM G42 1.5 Selection Triple salt 30

    ASTM G80 1.5 RT Triple salt 60

    ASTM G95 3.0 RT 3 % NaCl 90

    ISO 15711 1.05 RT Sea water 182

    AS 3862 3 mA Selection 3 % NaCl Selection

    NF A 49-711 1.5 Selection 3 % NaCl Selection

  • CD Results on Coating and Coating

    Notes: 1. The current draw corresponds to one sample being tested 2. The coatings were 800 to 900 m 3. CD tests were run with two 2-component liquid epoxy materials

    Standard Current

    [mA] Temp.

    [C] Duration

    [days]

    Disbondment [mm]

    Coating Coating

    CSA Z-245 5 - 7 65 28 2 - 4 11 - 14

    ASTM G8 20 - 25 RT 30 2 6

    ASTM G42 40 - 55 65 30 4 - 5 8 - 14

    ASTM G80 20 - 25 RT 60 2 6

    ASTM G95 25 - 30 RT 90 5 15 - 25

    ISO 15711 0.9 1.1 RT 182 7.5 13.5

    AS 3862 3 mA 65 28 2 - 3 10 13.5

    NF A 49-711 3 - 5 65 28 2.5 - 3 5 - 6

  • To develop a basis for a new international standard for a cathodic disbondment test method.

    NACE has formed a Technical Exchange Group, TEG #349x to investigate the effect of different test parameters on test results and document the results to assist the development of a new international standard.

    This paper is a status report on the progress made by the committee members of TEG #349X with the objective states above .

  • 1. Oxygen Concentration in the Electrolyte

    2. Electrolyte Type and Concentration

    3. Applied Potential

    4. Dry Film Thickness

    5. Test Duration

    6. Pre-treatment of the Substrate and Surface Profile

    7. Effect of hypochlorite

    8. Effect of Temperature

    9. Specimen Configuration Flat and Curved Steel

    10. Holiday Size

    11. Holiday Shape Cone or Straight Hole

    12. Specimen Orientation

    13. Selection of Reference Electrode and Its Calibration

  • Oxygen concentration

    0

    200

    400

    600

    800

    1000

    1200

    0 25 50 75 100

    Hours

    Dis

    bo

    nd

    ed

    are

    a [

    mm

    ] Oxygen

    Air

    Nitrogen

    Note:

    Dissolved oxygen concentration in the electrolyte affects the disbonding rate

    Specifically the disbonding rate increases with dissolved oxygen content

    Nitrogen atmosphere resulted in much reduced disbondment

  • Electrolyte solutions used in the CD test:

    synthetic seawater

    mixed salt solution

    NaCl solution

    The 3% by weight NaCl solution is considered the most suitable electrolyte solution.

    The NaCl solution offers high conductivity and does not form any calcareous deposit film on the metal surface.

  • Formation of Calcareous Deposits

    0

    50

    100

    150

    200

    250

    300

    350

    400

    0 20 40 60 80

    Days

    Cu

    rren

    t d

    en

    sit

    y (

    mA

    /cm

    )

    Reduction in cathodic current density with time for steel samples exposed in natural seawater polarized to -1050 mVSCE at 10C

  • Effect of Cation

    The rate of disbonding depends on the type of cation in the electrolyte. Disbonding was proportional to the molar conductivity of the cations.

    The anions normally have little effect on the disbonding rate.

  • Disbonding rate is a Function of Applied Potentials

    Linear relationship between applied potential and the disbonding rate.

    The charge transport through continuous coatings was found to increase with increasing cathodic potential.

    R2 = 0.7242

    0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    -1500 -1300 -1100 -900 -700 -500

    Potential mV SCE

    Dis

    bo

    nd

    ing

    rate

    (m

    m/

    h)

  • Dry Film Thickness

    For thin film coatings the disbonding rate was reported to decrease almost linearly as the DFT increased up to 100 m

    Disb. distance vs. coating thickness

    0

    1

    2

    3

    4

    5

    6

    7

    0 200 400 600 800 1000 1200 1400

    Coating thickness []

    Dis

    b. d

    ista

    nc

    e [

    mm

    ]

  • Dry Film Thickness

    Cathodic disbonding depends on transport of some reactants through the coating film.

    Thicker film slows the permeation of reactive species and the cathodic disbondment rate.

    The DFT of the test specimen should be clearly recorded in the test report.

  • Test Duration

    Cathodic disbondment increases with test time.

    Disbonded area is proportional to test time.

    12 weeks vs. 28 days : Longer test duration is highly recommended because cathodic blistering is more likely to be observable with the longer test

  • Pre-treatment of the Substrate and Surface Profile

    Surface profile and pre-treatment have significant impact on cathodic disbondment.

    The disbonding rate was found to decrease with increasing surface roughness

    Surface Pre-treatment: Phosphating the surface decreased the disbonding significantly.

    The steel surface profile shall be specified by the coating manufacturer and in the range of 2.0 to 4.0 mil (50-100 m).

    The surface profile and cleanliness shall be clearly recorded in the report.

  • Effect of hypochlorite

    Anode Reaction:

    2 Cl- Cl2 + 2 e-

    Cathode Reactions:

    2 H2O + 2 e- 2 OH- + H2

    O2 + H2O + 2e 2 OH

    Hypochlorite Formation:

    Cl2 + 2 OH- H2O + Cl

    - + ClO-

    Not normally seen in Field because of separation of anode from cathode (holidays in the pipeline coating)

  • Effect of ClO- concentration on Rate of Delamination

    0

    1

    2

    3

    4

    5

    6

    0 1 2 3 4 5 6 7 8

    Concentration [g/liter]

    Rate

    of

    Dela

    m. [

    m/d

    ay]

    Coating

    Coating

    Effect of hypochlorite

    For Laboratory Testing:

    Anode Isolation affects hypochlorite concentration

    Refresh the electrolyte solution at least every 28 days

    For smaller cell sizes, weekly changing of electrolyte solution is necessary

  • Effect of Temperature

    Cathodic disbondment increases with temperature

    For Laboratory Testing

    Qualification Tests, maximum service temperature, RT and/or 65 C to be optional

    Comparative coating performance, RT and/or 65 C

    Testing >100 C, the electrolyte shall be cooled down to 95 C

  • Specimen Configuration Flat and Curved Steel

    The specimen curvature had no significant effect on CD suggesting that flat or cylindrical samples can be used for CD testing.

    Coating Material

    Specimen Diameter/Curvature

    Cathodic Disbondment

    mm inch mm

    Coating (800-900 m)

    Flat Flat 3.0

    114 4.5 3.0

    60 2.2 3.1

    20 0.8 2.9

    Coating (800-900 m)

    Flat Flat 11.0

    114 4.5 11.0

    60 2.2 12.0

    20 0.8 10.0

  • Holiday Size

    Two holiday sizes, 1/8 (3

    mm) and (6 mm) are in common use for CD testing

    The holiday size made no significant difference to the CD test results

    For thicker DFT specimens, the hydrogen gas bubbles may be trapped at the smaller size holiday

    It is recommended to use only one holiday size of 6 mm for all coating specimens for the CD

    Coating Material

    Size Current, mA Cathodic

    Disbondment

    Inch (mm) Initial Final mm

    Coating

    (800-900m)

    1/8 (3.2) 3.5 11.8 3.0

    1/8 (3.2) 3.6 8.2 2.0

    (6.4) 12.2 29.0 3.0

    (6.4) 9.1 25.0 2.0

    Coating (800-

    900m)

    1/8 (3.2) 3.2 4.6 10.5

    1/8 (3.2) 3.0 7.2 13.5

    (6.4) 12.3 27.4 12.0

    (6.4) 11.7 23.1 12.0

    CD test results (-1.5 V, 65C, 28 days)

  • Holiday Shape Cone or Straight Hole

    Two popular ways to drill the holiday using either flat head end mill or cone shape drill bit

    There was no significant difference between the straight and cone shape holiday

    Coating Material

    Shape Size Current, mA

    Cathodic Disbondment

    mm Initial Final mm

    Coating

    Flat 3.2 6.7 10.2 2.0

    Cone 3.2 7.0 10.7 3.5

    Flat 6.4 20.6 26.0 4.0

    Cone 6.4 11.9 20.4 4.0

    Coating

    Flat 3.2 4.0 5.7 17.0

    Cone 3.2 6.4 11.0 15.0

    Flat 6.4 15.3 29.1 17.0

    Cone 6.4 15.1 22.6 13.0

    CD test results (-1.5 V, 65C, 28 days)

  • Specimen Orientation

    There are generally two orientations that can be used in the CD test; horizontal or vertical:

    There is no significant difference for the specimen orientation as long as the hydrogen gas bubbles escape freely and are not trapped at the holiday

  • Selection of Reference Electrode and Its Calibration

    Cu/CuSO4: up to 57 C

    Calomel: 60 C

    Ag/AgCl: up to 90 C

    Note that the accuracy of the electric potential measured by the

    reference electrode shall be checked.

  • CONCLUSIONS

    The disbonding rate increases with dissolved oxygen content.

    The rate of disbonding depends on the type of cation in the electrolyte.

    The anions normally have little effect on the disbonding rate.

    CD increases with decreased (more negative) potential.

    Thicker film slows the permeation of reactive species and the CD rate.

    Disbonded area is proportional to test time.

    Surface profile and chemical treatment affects cathodic disbonding rate.

    Hypochlorite formation in test attacks the coating.

  • CONCLUSIONS

    Cathodic disbondment increases with temperature.

    The specimen geometry has no impact on the cathodic disbondment.

    The holiday size variation of 3 6 mm has no impact on CD.

    Cone or straight shaped holiday has no influence on cathodic disbondment.

    There is no significant difference for the specimen orientation (flat or vertical)

    Ag/AgCl reference electrode is recommended

  • # Test Parameter Test Condition 1 Dissolved Oxygen

    Concentration in the Electrolyte

    Equilibrium solubility of oxygen in the electrolyte solution at the test temperature

    2 Electrolyte Type and Concentration

    3% by weight NaCl in DI water solution

    3 Applied Potential -1.5 VDC for buried pipeline coating and -1.0 VDC for offshore / marine structures, measured by Ag/AgCl reference electrode

    4 Coating Dry Film Thickness DFT shall be specified by the coating manufacturers for the specific field application.

    5 Test Time 12 weeks at maximum service temperature and 28 days (4 weeks) at room temperature (optional)

    6 Surface Pre-treatment and Surface Profile of Substrate

    The surface cleanliness and surface profile is very important and must be recoded.

    .

    RECOMMENDATIONS

  • # Test Parameter Test Condition

    7 Effect of hypochlorite Anode Isolation Changing the electrolyte solution

    8 Test Temperature Maximum service temperature and room temperature and/or 65 C (optional). Above 100 C, the electrolyte temperature shall be cooled to 95 C.

    9 Specimen Geometry Specimen can be either flat, curved panel or tube.

    10 Holiday Size 6 mm

    11 Holiday Shape Cone or Straight Hole

    Cone shaped drill bit to prepare holiday

    12 Specimen Orientation Specimen can lay flat horizontally with the attached cell or hang vertically in the bath.

    13 Reference Electrode and Calibration

    Cu/CuSO4, Calomel, or Ag/AgCl (latter recommended) can all be used in their allowable temperature range.

    RECOMMENDATIONS

  • Acknowledgements

    Thanks to members of NACE Technical Exchange Group TEG#349X for their valuable discussions on the evaluation of test parameters used in

    cathodic disbondment test methods.