2
PT Series Low-Amp Time Delay Relay Prevents dead ba�eries from add-on equipment, maximizing opera�onal readiness and saving maintenance costs. Delivers power to equipment a�er engine off or at end of shi� (video downloads), automa�cally �ming off and op�onally if ba�ery voltage is low. Protects sensi�ve on-board electronics via under-voltage and over-voltage shutdown. Ultra-Low Power Draw eliminates vehicle down�me due to dead ba�eries. Lowest off-state current draw (1.3 mA). Flexible Control Op�ons via Igni�on Key, alternator voltage sense, or both. Diagnos�c Feedback via on-board mul�- color LEDs Meets Stringent OEM Standards for electrical transient self-protec�on Adjustable OFF Time Delay: 15 minutes to 8 hours. 5 second test mode se�ng for quickly verifying installa�on. Bullet-proof Construc�on: Sealed unit, high temperature materials allow moun�ng anywhere on vehicle. Integrated thermal overload protec�on 4 Year Industry Leading Warranty

1111 Page Template for sales sheet - egismobile.com

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1111 Page Template for sales sheet - egismobile.com

PT Series Low-AmpTime Delay Relay

Prevents dead ba�eries from add-onequipment, maximizing opera�onal readinessand saving maintenance costs.

Delivers power to equipment a�er engine offor at end of shi� (video downloads),automa�cally �ming off and op�onally ifba�ery voltage is low.

Protects sensi�ve on-board electronics viaunder-voltage and over-voltage shutdown.

Ultra-Low Power Draw eliminates vehicledown�me due to dead ba�eries. Lowestoff-state current draw (1.3 mA).

Flexible Control Op�ons via Igni�on Key,alternator voltage sense, or both.

Diagnos�c Feedback via on-board mul�-color LEDs

Meets Stringent OEM Standards forelectrical transient self-protec�on

Adjustable OFF Time Delay: 15 minutes to 8hours. 5 second test mode se�ng for quicklyverifying installa�on.

Bullet-proof Construc�on: Sealed unit, hightemperature materials allow moun�nganywhere on vehicle. Integrated thermaloverload protec�on

4 Year Industry Leading Warranty

Page 2: 1111 Page Template for sales sheet - egismobile.com

Dip Switch Se�ng Op�ons & Features System Diagram

www.egismobile.com360.768.1211

Bellingham, WA U.S.A

* DISCONNECT BATTERY FROM POWER DISTRIBUTION SYSTEM BEFOREINSTALLING PRODUCT TO PREVENT ELECTRICAL SHOCK OR PRODUCT DAMAGE** Use of Igni�on On signal strongly recommended for all first responderinstalls to ensure rapid relay ON and maximize up-�me in adverse situa�ons.

DS1-DS3: Determines delay �me between Off Trigger event and Relay turningOFF, per table above. If DS1 through DS3= Off, Time Delay = 5 seconds fortes�ng and opera�onal verifica�onDS4-DS5: Determines Low Voltage Protec�on set-point or disables LowVoltage Protec�onDS6: Determines if The voltage being sensed on the input line will act as atrigger to enable Relay ON or ini�ate an OFF Trigger event towards eventualrelay turning OFF

Dimensions

Specifica�onsNominal Voltage (Vdc) 12Input Voltage Range (Vdc) 8.0-18.0Con�nuous Current (Amps) 30Installed Fuse (Ampere Ra�ng) 40ON Voltage Threshold (when used) 12.9OFF Voltage Threshold (when used) 12.7Low Voltage Protec�on (op�onal) (Vdc) 11.0 - 12.0Over Voltage Protec�on (Vdc) (15 sec) 17.0Opera�ng Current Draw (mA) 15Opera�ng Current (mA) Standby / Open 1.3Input Wire Size (Red) 12 AWG / 18 in.Output Wire Size (Orange) 12 AWG / 24 in.Igni�on Wire Size (Yellow) 18 AWG / 24 in.Ground Wire Size (Black) 18 AWG / 24 in.Housing Material Glass-Filled PolycarbonateMin Source Current (Yellow Igni�on Wire) 10 micro-Amps

Part Numbers Resell Pack Bulk PackPT Series 30 Amp Time Delay Relay 5601 5601B

* Custom configura�ons available including control harness wires,�me delays, voltage se�ngs, dip switch func�onality, and controlinput func�onality. Low minimum quan��es and short lead �me forsamples or produc�on. Contact us at [email protected] formore informa�on

Related Part Numbers Resell Pack Bulk PackRT Series 6 Posi�on Fuse Block 8028 8028BRT Series 6 Pos Fuse Block w/Gnd 8025 8025BCable Cap Insulator, 0.55 in Dia 4214

Methods of Opera�onRelay closes immediately if:

1) Key Igni�on Input > 8 Vdc or2) V_sense = On and Input Stud Voltage > ON Threshold Voltage

Relay opens a�er Time Delay se�ng if:1) Key Igni�on Input < 8 Vdc and V_sense = Off or2) Key Igni�on Input < 8 Vdc and V_sense = On and Input StudVoltage < OFF Threshold Voltage

UV / OV Lock (Under-voltage / Over-voltage Protec�on):1) If ON, will turn OFF Relay if Input Stud Voltage < LV DisconnectSe�ng or > OV Protec�on Voltage for Specified Dura�on2) Will turn OFF relay regardless of Key ON Accy Signal

60 m30 m15 m5 s

TIME DELAY

1328 h4 h2 h90 m

132

12.011.511.0OFF

45 LVDISC

ONOFF

6 VOLTSENSE

DS1DS6

Dip switch "Off" direc�on toward outsideEdge of device (as shown all switches Off)

POLICE

...................

= op�onalconnec�on