Upload
lookb64
View
214
Download
0
Embed Size (px)
Citation preview
8/3/2019 100e_5_1010 (web)
1/4100E 5 1010.fm/2 Schneider Electric9 avril 2002
References Functional systemin the switchboardCompact NS100/250, NB225
055516x6_
70
Description of deviceNumberper row
Compactcircuit breaker
100 A, vertical mounting, fixed,front-connected, toggle control
E56865
NB50 5
NB100 4
Compact andVigicompactcircuit breaker
160 A, vertical mounting, fixed,front-connected, toggle control,mounting on Multifix rail
E20793
NSA125/160Vigi NSA125/160
see page 100E_5_1030
Compact andVigicompactcircuit breaker
100 to 250 A, vertical mounting,fixed, front-connected
E49746
C100E 1
NB225, NS100/250, toggle handle 1
NB225, NS100/250 with measurementmodule toggle
1
NB225, NS100/250, direct or extendedrotary handle
1
NB225, NS100/250, motor mechanism 1
Vigi NS100/250, toggle handle 1
Incoming unit on a 160 A
switchboard
Vigi NS100/250, direct or extendedrotary handle
1
Vigi NS100/250, motor mechanism 1
051324
Compact andVigicompactcircuit breaker
100 to 250 A, horizontal mounting,plug-in, front-connected
NS100/250, 3P, toggle handle 1
E49747
NS100/250, 4P, toggle handle 1
Compact andVigicompactcircuit breaker
100 to 250 A, vertical mounting, fixed,front-connected
C100E 4
E21285
NB225, NS100/250, toggle handle 1
NB225, NS100/250, direct or extendedrotary handle
1
NB225, NS100/250, motor mechanism 1
Vigi NS100/250, toggle handle 1
Direct installation of the Polybloc unit07101 (nine 10 mmoutgoers per phase) downstream from the incoming unit.
Compact andVigicompactcircuit breaker
100 to 250 A, vertical mounting, fixed,front-connected (2)
E49748
NS100/160, toggle handle 4x2P, 4x3P, 3x4P
Incoming unit on a 250 Aswitchboard
NS100/160, direct or extended rotary handle 3x2P, 3x3P, 3x4P
NS100/160, motor mechanism 4x2P, 4x3P, 3x4P
048797r
NB225, NS250, toggle handle 4x2P, 4x3P, 3x4P
NB225, NS250, direct or extended rotary handle 3x2P, 3x3P, 3x4P
NB225, NS250, motor mechanism 4x2P, 4x3P, 3x4P
Vigi NS100/160, toggle handle 3x2P, 3x3P, 3x4P
Vigi NS100/160, direct or extended rotary handle (1) 3x2P, 3x3P, 3x4P
Vigi NS100/160, motor mechanism (1) 3x2P, 3x3P, 3x4P
Vigi NS250, toggle handle 3x2P, 3x3P, 3x4PVigi NS250, direct or extended rotary handle (1) 3x2P, 3x3P, 3x4P
Vigi NS250, motor mechanism (1) 3x2P, 3x3P, 3x4P
(1)For access to the Vigi module test button, order the special collar 29285with the circuit breaker.(2)Vertically mounted 100 to 250 A circuit breakers may be combined on the samerow under the following conditions: same type (normal circuit breaker or Vigi version),same control (toggle, rotary handle or motor mechanism), no terminal spreaders.
T R
8/3/2019 100e_5_1010 (web)
2/4100E 5 1010.fm/3Schneider Electric 9 avril 2002
References Functional systemin the switchboard (cont.)Compact NS100/250, NB225 (cont.)
Installation Upstream connection Downstream connect./distributionVerticalmodules
requiredH=50 mm
Mountingplate
Cut-outfront plate
Add. topfront plate
Add.bottom
front plate
Description Add.mod.
Add.front
plate
Description Add.mod.
Add.front
plate
E40178
E36983
E36984
E36985
E43263
E43990
E43266
E43991
5 07580 07839 direct to device 0 direct to device 0
5 07580 07839
4 07504+ 39993
07820 direct to device 0 direct to device 0
4 07515 07824 direct to deviceby prefabricated connectionassembly 07205 forcables > 90 mmif lugs are used,see device documentation
0
2 07802
direct to deviceby Polybloc distribution blockPolybloc 160 A 6 circ. 4P 07100Polybloc 250 A 9 circ. 3P 07103Polybloc 250 A 9 circ. 4P 07101Polybloc 250 A 12 circ. 4P 07102by 4P multi-stagedistribution block160 A, 15 circuits 07057250 A, 15 circuits 07058
by multi-hole terminalsterminals 6x35 (set of 3) 29248terminals 6x35 (set of 4) 29249by busbars (fixed devices)prefab. conn. for rear busbars160 A, 07033prefab. conn. for rear busbars250 A, 07034
0
0012
55
00
2
2
0780107801x2
0780507805
07802
07802
4 07515 07856
4 07517 07827
4 07518 07827
4 07515 07852
4 07517 07855
4 07518 07855
4 07534 07824 direct to deviceto terminal blocks
if lugs are used,see device documentation
05 07551 +
078054 07534 07824
5 07504+ 39993
07850 direct to device 0 direct to device 0
9 07516 07853 07802 07802 direct to devicevia spreadersspreaders 3P 31563spreaders 4P 31564
if lugs are used,see device documentation
0
11
0780107801
direct to deviceby 4P multi-stage distr. block160 A, 15 circuits 07057250 A, 15 circuits 07058
by multi-hole terminalsterminals 6x35 (set of 3) 29248terminals 6x35 (set of 4) 29249by busbars / prefab. conn. forrear busbars 250 A, 07037
0
55
00
0
0780507805
9 07517 07853 07802 07802
9 07518 07853 07802 07802
11 07516 07854 07802 07802
6 07516 07853 07801 direct to devicefrom busbars by 100 Aprefabricated connectionassembly 07038if lugs are used,see device documentation
0
0
direct to device 0
6 07517 07853 07801
6 07518 07853 07801
9 07516 07853 07802 07802
9 07517 07853 07802 07802
9 07518 07853 07802 07802
8 07516 07854 07801
8 07517 07964 07801
8 07518 07964 07801
11 07516 07854 07802 0780211 07517 07964 07802 07802
11 07518 07964 07802 07802
8/3/2019 100e_5_1010 (web)
3/4100E 5 1010.fm/4 Schneider Electric9 avril 2002
References Functional systemin the switchboard (cont.)Compact NS100/250
Description of deviceNumberper row
Manual sourcechangeover
100 to 250 A, vertical mounting,fixed, front connected,rotary handle
E21399
NS100/250with mechanical interlocking,ref. 29369 (from 05/99)
1
Visucompact (1) 100 to 250 A, vertical mounting,fixed, front connected,toggle control
E
21002
NS100/250,
Vigi NS100/250
1
(1)Cannot be installed behind door.
Upstream connectionConnection of 100 to 250 A units using cables u 120 mm2, with crimped lugs.
Only use the following lugs:
Cross-section of cables set Of 4 lugs
120 mm 29256
150 mm 29257
185 mm 29258
Accessories Description Cat. No.Divisible blanking plate H = 80, W = 122 07348
E46667
ONI
OOFF
ONI
OOFF
ONI
OFFO
trippe d
trippe d
ONI
OFFO
re set
res et
8/3/2019 100e_5_1010 (web)
4/4100E 5 1010.fm/5Schneider Electric 9 avril 2002
References Functional systemin the switchboard (cont.)Compact NS100/250 (cont.)
Installation Upstream connection Downstream connect./distributionVerticalmodules
requiredH=50 mm
Mountingplate
Cut-outfront plate
Add. topfront plate
Add.bottom
front plate
Description Add.mod.
Add.front
plate
Description Add.mod.
Add.front
plate
E40178
E51108
E36984
E36985
E43263
E43990
E43266
E43991
10 07579 07829 07802 07803 direct to device 0 use downstream couplingaccessoryref. 29358 3P and 29359 4P
0
11 07528 07888 direct to device
if lugs are used,see device documentation
0 direct to device
by 4P multi-stage distr. block160 A, 15 circuits 07057250 A, 15 circuits 07058by multi-hole terminalsterminals 6x35 (set of 3) 29248terminals 6x35 (set of 4) 29249by busbarsprefab. conn. for rear busbars
0
55
00
2
0780507805
07802
4P multi-stage distribution block
E56711
See page 120E_5_0035.
Polybloc
E49760
See page 120E_5_0045.
Rear busbars
E56712
See page 100E_5_1300.