11
1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

  • View
    232

  • Download
    1

Embed Size (px)

Citation preview

Page 1: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

1

Tissue Viability Imager – TiVi600 – Basic System SoftwareTissue Viability Imager – TiVi600 – Basic System Software

Welcome to the presentation

of

Page 2: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

2Use these buttons to load a sequence of images.

Click Automatic or Manual to scan through the sequence.

Page 3: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

3

Draw Regions of Interest (ROIs).

Page 4: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

4

Select the Express Wizard to display the Erythema Intensity and Area Diagrams.

Page 5: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

5

The Erythema Area Diagramdisplays how the areas of the patches inside the ROIs build up over time.

The Erythema Intensity Diagram displays how the red blood cell concentration inside the ROIs build up over time.

Page 6: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

6

The Group of Images window displays the average red blood cell concentration value of all images in a sequence.

Page 7: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

7

The Curve Tracker window displays the average red blood cell concentration value inside the ROIs of all images in a sequence.

Page 8: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

8

The Image Slicer window displays a slice of the red blood cell concentration along a selected line in the image.

Page 9: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

9

The Cross Section window displays the red blood cell concentration along a selected cross section for the entire set of images.

Page 10: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

10

Automatic calculation of average red blood cell concentration values above or below set threshold.

Page 11: 1 Tissue Viability Imager – TiVi600 – Basic System Software Welcome to the presentation of

11

Other TiVi600 basic system software features:

1. Automatic Alignment of images in a sequence.

2. Pixel-by-pixel Image Subtraction of any image in a sequence.

3. Digital Zoom-in links the macroscopic to the microscopic field of view.

4. Superposition of Image data on Photo possible.

5. Efficient data management using separate Project window.

6. All calculated data can be transferred to MS Excel®.

7. Creation of Video-clips to display time-compressed time series.