Upload
ilene-chapman
View
214
Download
0
Tags:
Embed Size (px)
Citation preview
1
SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries
US PATENT 8,415,822US PATENT 5,747,888
2
Hulda transformers Company Profile: Established in 1975 and is owned by Kibbutz Hulda. A part of (KIA) the Kibbutz Industries Association represents over 300
factories & Companies owned by the kibbutz association in Israel. It total KIA has 35,000 employees & over 8 billions US$ sales/year.
3
Main Markets: Military & Aviation transformers. Medical equipment manufacture. Cable TV industry.
Safety standard:CE, BABT, IEC, VDE & UL
Quality Assurance Management System:ISO 9001:2008 certified.
Hulda transformers Company
4
Mr David ZilberbergPrivet company
Hulda transformers Company
Kibbutz Industries Association (KIA)
Kibbutz Organization
CATV Upstream noise blocker (UNB)
CATV Patented Powering
Kibbutz Hulda
5
Safecom's proven, patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns CATV Optical & HTC networks into a super power synergy platform that provide most reliable and economic powering system for unlimited backup time.
Safecom Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without
Batteries
DPS v5Power Booster 4GSYNERGY-2
Dual T-former 2X 15A 60,66,72,87 V +
DOCSIS Monitoring
Dual outputs T-former 15A (Indoor -Europe
Standard ) 60,66,72,87 V
6
Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the distant available source over existing coax or power cables. Utilizing breakthrough direct AC/AC On-Line stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances.
The Backup Power concept .
Unlimited backup Power for CATV networks & Without Batteries (60V & 90 V standard)
7
Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPSv5 draws power from the distance available source over existing coax or power cables.
Safecom's proven smart grid technologies greatly improve network powering reliability while creating significant savings in both capital and operational expenses.
1 2
3 4Power +
Signal
To remote / Node / Amplifier
Optical Node/Trunk
amp
P.S
2
1
3
4
AC 1 input .AC 2 input
Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp)
DPS V5US PATENT 5747888 EP 0708559
Power Booster
Port
Monitoring Port: voltage,
RF PASS 5-1000 MHZ
AC 1
Local Remote
Current, status
AC 2
Unlimited backup Power for Optical & HFC networks Without Batteries
8
MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK. INCREASING THE POWERING AREA COVERED BY POWER SUPPLY
Vin 30-87Vac (US)Vin 30-64Vac (EU)
tv
tv
Vout 87 Vac (US) Vout 60 Vac (EU)
US PATENT 8,415,822
POWER BOOSTER US PATENT 8,415,822
Utilizing patented breakthrough direct on-line zero crossing AC/AC stabilize technology safecom's ensures an optimal voltage level to Optical Nodes & Line Amplifiers even the source of power from over long distances. Passive, Standalone element, power booster solves the power distribution problem in a CATV network caused by high-resistance and low energy efficient coax & electricity cables.
RF PASS 5-1000 MHZ
9
Power Booster – the 4G Transmission New Power Booster 4G
Integrated Dual Power inserter. Stand alone unit.
RF PASS 1GHZ
Voltage gain 1: 1.56 enabling up to double powering distance.
coverage area
Zero crossing - Smooth transition between conversion levels.
Technology
4 Automatic gears AC/AC transformation
gears
100 mA (EU model) 200 mA (US model)
Self current load
10
• All in One two-way RF Pass 1GHZ passive device that “toggle” available Power between two distant locations.• Redirecting power from the "normally" remote powered area to the area subject to power outage.• During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. • Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S. =
DPS V 4 Power Booster
SYNERGY-2US PATENT 8,415,822
AC 1 input .AC 2 input Local output to local Optical Node. (AC+RF)
Backup IN.OUT (AC+RF to remote Node/ amp) 12
34
Power +
Signal
To remote / Node / Amplifier
Optical Node/Trunk
amp
P.S
21
3 4
+
Unlimited backup Power for Optical & HFC networks Without Batteries
11
Inputs/ Output configuration
Monitoring Inputs/outputs
ONLINE Current & Voltage +
status .
AC 2 - Input AC1 - Input
RF / AC 5-1000MHz 15A OUTPUT To Local Amplifier / Node
RF / AC 5-1000Mhz 15AINPUT / OUTPUTTo / From Remote Amplifier / Node
US PATENT 8,415,822
Vin 30-87V Vac (US)Vin 30-64V Vac (EU)
t
v
tv
Vout 87 Vac (US)Vout 60 Vac (EU)
• Inside view: SYNERGY-2 60/87V -2x15A
12
SYNERGY 2 the New generation.
Previous generations of DPS DPS Ver 4 SYNERGY-2
Limited by cable conductivity and Voltage drop.
External Power Booster required depend on voltage level when using remote powering.
Improved – Integrated power Booster (ALL in ONE). Remote backup powering
Required stabilizing P.S. (Ferro or T-former)
Required stabilizing P.S. (Ferro or T-former)
Improved .No required stabilizing P.S. Build in online zero crossing voltage stabilizer.
Stabilizing Voltage
External Dual power Inserter is needed Integrated Dual Power inserter. Integrated Dual Power inserter. Power Insertion
Required Two units. One unit. (+ optional Power Booster) One unit. Installation
--- Direct Monitoring outputs Via one Cable to IP transponders.
Direct Monitoring outputs Via one Cable to IP transponders. Monitoring
Unlimited backup Power for Optical & HFC networks Without Batteries
13
US PATENT 8,415,822Dual Port P.S + Docsis / EuroDOCSIS monitoring
NEW UR – Ultra Range +/- 25% Vin
aaaa a
a
a
DOCSIS® & EuroDOCSIS Status Monitoring, Embedded Transponder.
Direct RF connection to CATV network
Output 260,66,72 15A
Output 160,66,72 15A
External Monitoring DPS, SYNERGY-2 & more
Dual Port P.S model SC-D-TFPS-1800-E-O-M2 ports X 15A 60,75,87Vac 50/60 Hz .
Direct connection .Direct connection .
Voltage testing points
Current loop testing points
(For Clamp meter )
14
15
NEW-Dual Port P.S model SC-D-TFPS-1800-EOM2 ports X 15A 60,75,87Vac 50/60 Hz .
16
Direct RF connection to CATV network
Output 260,66,72 15A
External Monitoring DPS, SYNERGY-2 & more
NEW-Dual Port P.S model SC-D-TFPS-1800-UOM2 ports X 15A 60,75,87Vac 50/60 Hz .
Direct connection .
Output 160,66,72 15A
Direct connection .
Voltage testing points
Current testing points
Secondary AC input / Generator
Main AC input
Phase changer
120 KA SURGE SUPPRESSION
DOCSIS® & EuroDOCSIS Status Monitoring, Embedded Transponder.
17CATV Dual Port P.S 1350VA 15A 60,72,87V
Model SC-STFPS-1350-90EI
For hanging or shelf-lain mounting.
NEW-Dual Port P.S model SC-D-TFPS-1350-90UI2 ports, 15A 60,75,87Vac 50/60 Hz .
18
SYNERGY-2 Typical configuration Optical node + Trunk amplifier (or second optical node) .
Power + Signal
From Optical node 4
21
3
1234
AC 2 input .AC 2 input
Local output to local Optical Node. (AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
Optical Node21
3 4To remote / amplifier / Node P.S
.S
P.S
60V
60V
Optical NodeOr Trunk amplifier
60V60V
Area A
Area B
Unlimited backup Power for Optical & HFC networks Without Batteries
19
From Optical node
1234
AC 2 input .AC 2 input
Local output to local Optical Node. (AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
21
3 4To remote / amplifier / Node P.S
.S
P.S
SYNERGY-2 – Demo backup power from Area A to Area B
Power + Signal
60V55V50V
45V60V
Area A
Area B
21
43340V 60V
40V 60VOptical Node
Or Trunk amplifier
Optical Node
Unlimited backup Power for Optical & HFC networks Without Batteries
20
Power + Signal
To Optical node4
21
3
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
21
3 4From remote amplifier / Node
P.S.S
P.S
45V50V
55V
60V 60V
SYNERGY-2 – Demo backup power from Area B to Area A
P.S
Area A
Area B
40V 60V
Optical NodeOr Trunk amplifier
Optical Node
Unlimited backup Power for Optical & HFC networks Without Batteries
21
SAFECOM’s powering system around the world.Reliability since 1994
22
Power backup Comparisons
Synergy-2 / DPS V4
T-Former
Generators Non Standby
Standby + Batteries
Power Type
Low High Low High Cost
Zero Permanent Negligible Permanent Maintenance
UnlimitedLimited by
fuelNone
2 to 3 hour(Depends on batt.
condition )Backup Power
Low costVery
expensiveLow Very Expensive
Redundant/ Diversity
Optional NON NON NONIntegrated Surge Suppressor 120K
Optional NON NON NONIntegrated Phase
Changer
23
Typical optical network powering examples
24
90V-network60V-available
Deep Fiber Network 60V- SYNERGY backup power
60V-network90V-available
25
60V-network90V-available
HFC Network 90V- DPS5+ Power Booster backup power
90V-network60V-available
26
Deep Fiber Network 90V- DPS5+ SYNERGY backup power
90V-network60V-available
27
Business case.
Improving customer service and satisfaction. Enabling MSO to add new services that required top high
reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy.
28
Complete Tree-View Import using CSV files• Also can discover One node at a time from the UI (on –demand discovery)• Network discovery• Export the Tree-View for further Use
1. Discovery can be backed up2. Automated Full Topology DPS/ SYNERGY back up
Auto Discovery of the PS Monitor• Supports any device that has an SCTE-HMS-PS-MIB• Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB)• Auto Generates Attribute Widgets with properly formatted thresholds• Supports all Adjacent devices like APC, Cordex Controllers etc.• Supports Discrete Thresholds
DOCSIS® & EuroDOCSIS Status Monitoring
29
• Monitors the Attributes – Pre-Configured Poll Interval– Summarization (Hourly, Daily)– Graphing (Single or Multiple attributes)– Attribute Refresh (on demand)
• Monitors the Current Alarm Table– Generates the Events from this table– Auto Correlation (If the alarm is pre-existing, does not generate a new
Alarm)– Updates the Tree-view with corresponding Severity – If SNMP Traps are enabled, It will auto-correlate the incoming traps with
Current Alarm table
30
Google Maps Integration
31
ON-LINE REPORT
32
Europe 60V & US 90V Standard. Support full 15A rms input /output. Prefect voltage at the remote location in the network. Water-proof Enclosure. (IPX8)�� Opposite connection protected. Input & Output Surge Protection.�� DOCSIS® & EuroDOCSIS Status Monitoring. Online RF transmission during operation. (INTERNET, VOD,
VOIP)
DPSv4 / SYNERGY-2/ Power Booster
Power Innovation
Standard Features
33
Summery SAFECOM SYNERGY-2 & DPSv5 & Power Booster offers CATV operators the
most efficient and reliable complete backup solution for an unlimited time at minimum cost.
No additional cost for MSO further to the fact that SYNERGY-2 / DPS v5 unit can be reused from HFC network to full optical network.
Following the government regulation for full powering backup. SYNERGY-2, DPSv5 & Power Booster systems, enabling additional backup from
remote powering. No maintenance. Unlimited lifetime. Two way powering on a single cable (Coax or electrical cable) Full DOCSIS® & EuroDOCSIS Status Monitoring
34
Thank you