2
0470 Head Office / 1st Factory Industrial Zone 861-10, Toegye-dong, Chuncheon-si, Gangwon-do, Korea (ZIP code 200-944) TEL: + 82. 70. 7119. 2540 FAX: + 82. 33. 264. 5999 e-mail: [email protected] www.mek-ics.com Branch Office / 2nd Factory 5th Floor, A-dong, Woolimlionsvalley 5th. #144-3,4 Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, South Korea (ZIP code 462-739) TEL: +82. 70. 7119. 2520 FAX: +82. 31. 735. 2761 e-mail: [email protected] www.mek-ics.com Pneuma Series Features Pneuma 1 MODE Dual Limb Dual Limb Single Limb Single Limb * Single Limb * Ex-Valve * Single Limb * Ex-Valve PSIMV VACV PACV VSIMV AUTO (Emergency quick start) Spont+ PRVC O2Stream® ACPAP+ ABIPAP+ Pneuma 2 Optional Nasal Cannula for O2Stream® Remark : * single limb * - Single limb circuit with external exhalation valve SpO2 EtCO2 Peripherals High Pressure Oxygen Mixer Exhalation Drive Line Input Low Flow Oxygen Supply Inlet Proximal Pressure Line Input Trend Trend (72hrs)

1. MTV1000 - PNEUMA(Eng).pdf

Embed Size (px)

Citation preview

  • 0470

    Head Office / 1st Factory

    Industrial Zone 861-10, Toegye-dong, Chuncheon-si, Gangwon-do, Korea(ZIP code 200-944)

    TEL: +82. 70. 7119. 2540 FAX: +82. 33. 264. 5999e-mail: [email protected] www.mek-ics.com

    Branch Office / 2nd Factory

    5th Floor, A-dong, Woolimlionsvalley 5th.#144-3,4 Sangdaewon-dong, Jungwon-gu, Seongnam-si,Gyeonggi-do, South Korea (ZIP code 462-739)

    TEL: +82. 70. 7119. 2520 FAX: +82. 31. 735. 2761 e-mail: [email protected] www.mek-ics.com

    Pneuma Series FeaturesPneuma 1

    MODE

    Dual Limb Dual LimbSingle Limb Single Limb*Single Limb*Ex-Valve

    *Single Limb*Ex-Valve

    PSIMVVACV

    PACV

    VSIMVAUTO (Emergency quick start)Spont+

    PRVCO2StreamACPAP+ABIPAP+

    Pneuma 2

    OptionalNasal Cannula for O2Stream

    Remark : *single limb * - Single limb circuit with external exhalation valve

    SpO2

    EtCO2

    Peripherals

    High Pressure Oxygen Mixer

    Exhalation Drive Line InputLow Flow Oxygen Supply Inlet

    Proximal Pressure Line Input

    Trend Trend (72hrs)

  • [Technology] It is decreased Inspiratory Phase Work of Breathing through Inspiratory Trigger function and Pressure Support function. It makes possible to inhalation with small effort of patient (WOB_inspiration). It is decreased Expiratory Phase Work of Breathing through Ex_Sesnse. In this time, interrupt the flow rapidly and supply brk_time (Expiration Break Time). It makes possible to exhalation with small effort of patient (WOB_expiration) and minimize of breaths with difficulty.

    * (brk_time: Expiration Break Time): Application to most convenience respiration pattern.

    MTV 1000

    O2 streamRecently the clinical aim of ventilator is minimized of lung injury and recovered of spontaneous respiration. It should be deal with carefully that interrupt ventilation and assistance of breathing in clinically. After weaning by ventilation, it may happen to use the ventilator (or assistance of breathing) again frequent. That is necessary a method for proper and effective assistance of breathing. The High Flow Therapy is suitable device for the method and it is contrived by principal that makes sufficient ventilation in the nasal cavity and upper airway. In this aspect, it isdifferent from Nasal CPAP. This function is using with Nasal Cannula was contrived specially and use with humidifier.

    ACPAP+(Adaptive CPAP Plus Pressure Support)

    [ACPAP+ Function] It is developed with high technology which applying to the highest class ICU ventilator and applying for a patent. It is innovated reaserch object comfortable breathing in CPAP. MEKICS created unique ACPAP+ technology completed the clinical effect and comfortable breathing simultaneous.

    [Principal] Based on the CPAP, it is contrived to minimize of breaths with difficulty in CPAP as induction of airway open, pressure support that is decreased patients effort in inspiration, and active break (rapid pressure interruption) that makes easy of expiration.

    Encorder for setting parameter 7 Color TFT Touch Screen

    LAN, USB RS-232 Upgrade Port

    Optional : SpO2, EtCO2

    Proximal Pressure Line InputExhalation Drive Line Outlet

    Home Care.

    Transport.

    Hospital.

    Pneuma1

    Pneuma1

    Pneuma2

    Dual Limb Circuit >PACV, PSIMV, VACV, VSIMV, Spont(Spont+PS) , PRVC,Apnea Back-up Ventilation, AUTO(Emergency Quick Start)

    Single Limb Circuit >PACV, PSIMV, PRVC, Apnea Back-up Ventilation.ACPAP+, ABiPAP+Optional : SpO2, EtCO2

    Dual Limb Circuit >PACV, PSIMV, VACV, VSIMV, Spont(Spont+PS), PRVC, AUTO(Emergency Quick Start), Apnea Back-up Ventilation.

    Single Limb Circuit >PACV, PSIMV, PRVC, Spont(Spont+PS), Apnea Back-upVentilation, ACPAP+, ABiPAP+,O2 Stream with high flow oxygen supply.with High Pressure Oxygen MixerOptional : SpO2, EtCO2, Nasal Cannula for O2Stream

    Multi Purpose Ventilator forHospital, Long Term Care and Transport

    Trigger

    Pressure

    Flow-Machine

    Flow-PatientEx.time

    =Easy Expiration

    PSV

    Quick Pause