Upload
marilynn-hutchinson
View
240
Download
3
Embed Size (px)
Citation preview
1GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650Generator Protection & Control System
Protection, Control and Monitoring
for Generator Interconnection
g Multilin
2GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
Agenda
• G650 Protection Applications• Features and Benefits• Protection Functions• Control Functions• User Programmable Control
Logic• HMI Monitoring and Control• Metering and Monitoring• Communications• EnerVista Software• Ordering Information• Summary
G650 Generator Protection & Control System
3GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
Cost Effective Integrated Solution for:
• Protection and Control of Small to Medium sized Generators
• Distributed Generator Management
• Generator Interconnect Protection
• Generator Sets Mains Failure Detection
G650 Generator Protection & Control System
4GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
Best Value for Price Solution Available
• Basic and Enhanced Protection Options available to suit your Generation Protection Requirements
• Ready for basic breaker Trip and Close Control with no programming required
• Provides IEC61131-3 Programmable Logic for customizing interaction with the Prime Mover Control System
• High End Fault, Disturbance and Sequence of Events recording capability
• Supports open communications protocols such as Modbus and DNP for system integration
• Large graphical built-in interface providing local control
G650 Generator Protection & Control Solution
5GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Protection features
Basic Protection Option
• Timed & Instantaneous Overcurrent• Directional Overcurrent • Voltage Restraint Overcurrent• Under and Overvoltage • Directional Power• Under and Overfrequency • Frequency rate of change• Generator Thermal Model• Generator Current unbalance • Loss of Excitation• Accidental Generator Energization
6GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
Enhanced Protection Option
All Basic Protection Elements Plus:
• Sensitive Ground Overcurrent • Volts/Hz • Power Factor limiting • Loss of Mains detection • Breaker Failure • VT Fuse failure • Restricted Ground Fault
G650 . . . Protection features
7GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Control functions
Built-In Control Functions
• Synchrocheck Element for ensuring synchronism before closing the Breaker onto the system
• Control of switching between the 3 available Setting Groups
• Analog Comparators allowing users to create their own customized control elements
• Trip Circuit Supervision ensuring integrity of the Tripping Circuit
• Contact Seal-In preventing damage to the trip contact due to opening when the Trip Circuit is active
Trip Circuit Supervision ensures the circuit is available for Tripping when required
8GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Control logicPre-Configured Control Logic
The G650 comes preconfigured with Control Logic for standard Tripping and Closing operation. Users are only required to configure the protection or control element they wish to use.
User Programmable Control Logic
The IEC 61131-3 programmable Logic Editor allows users to develop their own Logic equations and create their own customized Distributed Generation Control Applications
9GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Front panel HMI
User Friendly and Intuitive HMI
10GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
Customizable single line diagrams• ANSI Symbols library• Editable using PC program• Available only in 16 x 40 character display
Customizable Single Line Diagram
G650 . . . Front panel HMI
11GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
Accurate Metering of Power System Values
• Current (+/- 0.5%) • Voltage (+/- 1%) • Power - Real, Reactive, Apparent(+/-
1%) • Energy (+/-1%)• Demand (+/-1%)• Power Factor (+/- .02)• Frequency (+/-30mHz 50Hz, 36mHz
60Hz)
View Real-Time Metering Data using the 650 Setup Program
Analyze Input and Output states using the Viewpoint Monitoring
software HMI
G650 . . . Metering & status values
Real Time Status of I/O Data•Contact Inputs•Contact Outputs•Virtual Inputs•Virtual Outputs•Trip Circuit Supervision Status
12GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Fault recording
Sequence of Event Records• Stores the last 479 events• Time stamped to 1mSec accuracy
Oscillography Waveform capture• Stores up to 20 fault records• Sampling rate of 64 samples/cycle• Records 9 Analog channels• Records 16 Digital Channels • Programmable Oscillography Trigger
Data Logger• Long term trending of measure data• 1 second to 60 minute sample
resolution• 16 recordable analog channels
The High Sampling Rates and Large amount of storage capacity make the G650 ideal for all your Fault and Disturbance Recording needs
Timestamping of Events with 1ms accuracy
High-Sample recording of Generator Faults
13GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . CommunicationsMultiple Communication Mediums and Protocols Simplifying Configuration & Integration
RS232 Serial Front Port• 300 to 115,200 Baud Rates• Modbus RTU, DNP3.0 Protocols
RS485 Serial Ports• 300 to 115,200 Baud Rates• Copper, Glass Fiber, Plastic Fiber mediums• Modbus RTU, DNP3.0 Protocols
CANbus I/O Ports• Asynchronous I/O data sharing• Copper, Glass Fiber mediums
Ethernet Ports• 10/100Mbit TX Copper• Redundant 100Mbit FX Fiber• Modbus TCP/IP, DNP3.0, HTTP, TFTP
Protocols
14GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . EnerVista Software
Device Setup & Document Management Toolset Easily configure GE Multilin devices from a single Application Create and Edit setting files Offline, or in Real Time Manage your Support Documents & Software Tools Receive Automatic Notification of new updates
Easy to Use Monitoring and Data Recording for Small Systems Pre-configured screens for Instant Monitoring Single-Line monitoring Annunciator Alarms Trending Reports Automatic Fault Data Collection
Communications Server OPC/DDE Server Send device data to HMI, DCS, and SCADA systems Contains memory maps for GE Devices and firmware Automatic Fault Data Collection
15GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Viewpoint Monitoring Software
SINGLE-LINE MONITORING AND CONTROL
Create and View Single-Line monitoring screens in minutes
TRENDING REPORTS
Historical Record of Monitored Data
PLUG-AND-PLAY MONITORING
Pre-configured screens for instant monitoring
View Waveforms Recorded From your Devices
AUTOMATIC EVENT AND WAVEFORM RETRIEVAL
Effortless Data Archiving
AUTOMATIC EVENT AND WAVEFORM RETRIEVAL
Instant Alarm Notification
Global COMTRADE VIEWER
17GE Consumer & Industrial
MultilinCopyright © 2006 GE Multilin
G650 . . . Summary• Ideal for Distributed Generator Applications
• Contains all required protection features for small to medium sized generators• Provides configurable logic for creating customized generator system control
schemes
• Cost Effective and Scalable Solution where a low price of protective relaying is key driver
• Basic and Enhanced Protection Options to suit individual application• Graphical User Interface and Communication options to suite integration
requirements
• Industry Leading Fault Recording Capability• Large capacity and highly accurate Sequence of Event Recording• Waveform Fault recoding with High Sampling rates (64 samples/cycle) and
multiple record storage • Long term Data Logger recording of system disturbance events (up to 1
sample/second)
• Most features available in the Distributed Generation Protection market segment• Programmable Control Logic• Ethernet Communications• High End Fault Recording