1 A first design of the PEP-N A first design of the PEP-N Calorimeter Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N Calorimeter Group Brief presentation of KLOE calorimeter Brief presentation of KLOE calorimeter Schematics of PEP-N calorimeter Schematics of PEP-N calorimeter Simulations: reconstruction and TOF Simulations: reconstruction and TOF

1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

Embed Size (px)

Citation preview

Page 1: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

1

A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri

Laboratori Nazionali di Frascati INFN

for PEP-N Calorimeter Group

Brief presentation of KLOE calorimeterBrief presentation of KLOE calorimeter Schematics of PEP-N calorimeterSchematics of PEP-N calorimeter Simulations: reconstruction and TOFSimulations: reconstruction and TOF

Page 2: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

2

24 barrel modules60 cells (5 layers)

4.3m length

2 × 32 endcap modules

10/15/30 cells

2440 cells2440 cells 4880 channels4880 channels

Fiber choice: Kuraray SCSF-81 and Pol.Hi.Tech 0046

PM choice: Mesh Hamamatsu R5946

KLOE CALORIMETER OVERVIEW

Page 3: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

3

The KLOE EMC is a fine sampling lead/scintillating fibers calorimeter

Volume Ratio Fiber:Lead 50:50Energy sampling fraction 13 %<X0>= 1.6 cm <>=5.3 g/cm3

1.2 mm

Lead

1.35 mm1.0 mm

52.5 cm

15X0

430 cmPure “em” calorimeter … no compensation

High light yield and good energy resolution due to fibers’ choice

Excellent time resolution driven by fast time emission in the fibers and small light path dispersion along the fibers’ length

THE CALORIMETER STRUCTURE

N.B. the particles impinging on the calorimeter cross the fibers “almost” orthogonallyN.B. the particles impinging on the calorimeter cross the fibers “almost” orthogonally

Page 4: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

4

Title: fig11.ps Creator: XV Version 3.10a Rev: 12/29/94 - by John Bradley Preview: This EPS picture was not saved with a preview (TIFF or PICT) included in it Comment: This EPS picture will print to a postscript printer but not to other types of printers Light guides at one end of a barrel module

before photo-tubes installation

Light guides at one end of a barrel module before photo-tubes installation

Page 5: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

5

Title: (C:\\WINNT40\\Profiles\\Paolo\\Desktop\\12-2000\\CalNim\\Figs\\Exploded.eps) Creator: (CorelDRAW 8) Preview: This EPS picture was not saved with a preview (TIFF or PICT) included in it Comment: This EPS picture will print to a postscript printer but not to other types of printers Exploded view of the PM boxExploded view of the PM box

Page 6: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

6

Average energy scale:

40 MeV/MIP

Using the number of pe/MIP measured at CRS: light yield of

1000 pe/GEV/side @ calorimeter center

A factor 2 more light at the calorimeter boundaries

Energy resolution dominated by sampling fluctuactions

No cuts have been made on “holes” or specific detector regions

LINEARITY IN ENERGY RESPONSE AND ENERGY RESOLUTION

e+e- e+e-

Page 7: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

7

TIMING RESOLUTION

Behaviour of t

as a function of the energy is reported using all relevant ’s samplesComparing the difference of timing between two clusters at small and large angle we estimate that of the 147 ps of constant term:

50 ps mis-calibration

55 ps bunch spread

125 ps machine time spread

Page 8: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

8

Measured efficiency in Kloe calorimeterMeasured efficiency in Kloe calorimeter

Page 9: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

9

Summary of KLOE-type SciFi calorimeterSummary of KLOE-type SciFi calorimeter

Spatial resolution transverse ~1.5 cm

  longitudinal 1.2/E cm/GeV

Energy resolution   0.06/E 1/GeV

Time resolution   54/E[GeV]+ 147 ps

Radiation length   1.5 cm

Energy sampling frac.   13 %

Page 10: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

10

Perspective view of the PEP-N calorimeterPerspective view of the PEP-N calorimeter

Page 11: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

11

Forward calorimeterForward calorimeter

Page 12: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

12

Montecarlo efficiency of 10 cm thick Montecarlo efficiency of 10 cm thick Kloe-type calorimeterKloe-type calorimeter

Page 13: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

13

Montecarlo energy resolution of 10 cm thick Montecarlo energy resolution of 10 cm thick Kloe-type calorimeterKloe-type calorimeter

Page 14: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

14

energy distributionenergy distributionFCAL, RCAL (top) BCAL, PCAL (bottom)FCAL, RCAL (top) BCAL, PCAL (bottom)

Title:matteo_his_en.epsCreator:HIGZ Version 1.26/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.

Page 15: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

15

K- K- time-of-flight difference time-of-flight difference

Delta TOF

0.00

1.00

2.00

3.00

4.00

200 300 400 500 600 700 800 900 1000 1100

Momentum [Mev/c]

De

lta

TO

F [

ns

]

kappa-pi TOF 60 cm (PCAL)+ 280 ps - 280 pskappa-pi TOF 125 cm (FCAL)+ 280 ps - 280 ps

Page 16: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

16

TOF distribution in FCAL, BCAL and PCALTOF distribution in FCAL, BCAL and PCALTitle:pepnt_12_his.epsCreator:HIGZ Version 1.26/04Preview:This EPS picture was not savedwith a preview included in it.Comment:This EPS picture will print to aPostScript printer, but not toother types of printers.

Page 17: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

17

Page 18: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

18

Page 19: 1 A first design of the PEP-N Calorimeter A first design of the PEP-N Calorimeter Presented by P. Patteri Laboratori Nazionali di Frascati INFN for PEP-N

19