SHEET : P1.0
Scale: As Noted
FIRST FLOOR SANITARY
SEWER & STORM WATER
FIRST FLOOR SANITARY SEWER AND
STORM WATER PIPING PLAN
Scale: 3/32" = 1'-0"
Checked By: MJV
Drawn By: JP
Designed By: JP
MA
TT
HE
W J. V
ER
TU
CC
I
PA
. L
IC
. N
O. P
E-0
60
40
5
Ve
rte
ch
E
ng
in
ee
rin
g A
sso
cia
te
s
24
4 D
an
ville
R
oa
d
Blo
om
sb
urg
, P
en
nsylva
nia
1
78
15
Ph
on
e: (5
70
) 4
37
-2
10
0
Fa
x: (5
70
) 4
37
-3
10
0
NE
W C
HE
VR
OL
ET
/ V
OL
VO
D
EA
LE
RS
HIP
F
OR
:
Gre
en
ca
stle
, P
en
nsylva
nia
An
trim
T
ow
nsh
ip
, F
ra
nklin
C
ou
nty
AL
EX
AN
DE
R F
AM
IL
Y D
EA
LE
RS
HIP
S
BA
M Jo
b #
: 2
00
0
Date: August 1, 2016
EN
GIN
EE
R
J
K
M
N PO
HOSE
REEL
L
UP
FIRE SEPARATION LEGEND
- 1 HOUR SEPARATION
- 2 HOUR SEPARATION
UP
37 12
36 13
34 15
11
09
08
3x5 DS
04
02
01
03
24 21
23 22
29
30
31
33 16
32
10
06
35 14
UP
AA
HC
BE
NC
H
HCHC
07
05
KEY
DROP-BOX
26 19
25 20
28 17
27 18
KEY
DROP-BOX
D W
UP
UP
WASH / DETAIL
BAY
WASH / DETAIL
BAY
WASH / DETAIL
BAY
WASH / DETAIL
BAY
QUICK LUBE
BAY
QUICK LUBE
BAY
QUICK LUBE
BAY
QUICK LUBE
BAY
SERVICE LANES
123
ELEV. MACH.
150
PARTS
STORAGE
152
SHOWROOM
139
ELEV.
LOBBY
148
BUS. DEV.
CENTER
142
SERVICE WRITE-UP
124
MEN
128
WOMEN
129
RETAIL
PARTS
130
HOSPITALITY
131
PARTS
COUNTER
154
SALES
137
SALES MGR.
144
CHILDREN
133CUST. LOUNGE
132
TECH TLT.
155
F&I
143
TECH LUNCH
158
VEST.
138
CORRIDOR
145
CORRIDOR
126
TECH
LOCKER
156
FILES
127
SERVICE MGR.
125
ELEV.
SALES
136
ASST.
SVC. MGR.
153
RECEIVING
151
SALES
147
SALES
146
SALES
135
TOOL ROOM
120
MECH. ROOM
119
SERVICE BAYS
121
CORRIDOR
140
TECH
SHOWER
157
STORAGE 141
STORAGE
123b
TECH. TLT. 112
SERVICE WRITE-UP
114
SERVICE MGR.
113
MEN 108
WOMEN
109
JAN.
110
CHILDREN
111
LIVING ROOM
101
SALES 106
CONSULT. 105
SALES
104a
F&I
103
SALES MGR.
102
VOLVO
SHOWROOM
100
SERVICE LANES
115
AUTOMATIC
CAR WASH
118
EQUIPMENT
COMMON
AREA
122
SALES
134
TLT.
149
STAIR
#1
STAIR
#2
HC
HC
HC
HC
HC
HC
HC
HC
HC
UP
NORTHNORTH
NEW CAR
DELIVERY
NEW CAR
DELIVERY
FOUNTAIN
KNOX
BOX
CO
VE
RE
D
WA
LK
WA
Y
MECH.
ROOM
116
ELEC.
ROOM
117
CHEVROLET
NEW TIRE DISPLAY
VOLVO
NEW TIRE DISPLAY
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
HC HC
STOR.
105a
SALES
104
SALES 107
DW
DS
SUMP
PIT
E
FG
B
C
SALT
H1
H
WASH
DOWN
PUMP
4" CO
UNDERGROUND STORM
WATER PIPING BY SITEWORK
CONTRACTOR.
SEE SITE DRAWINGS FOR
CONTINUATION.
ZURN Z886-HD-DGC
6-1/4" WIDE REVEAL
TRENCH DRAIN
(17) 80" SECTIONS.
INSTALL w/
RUNNING TRAP
3000 GALLON DOUBLE BASIN HIGHGUARD OIL INTERCEPTOR
AS MANUFACTURED BY HIGHLAND TANK & MFG. CO.
ALTERNATE MANUFACTURERS ARE ACCEPTABLE PENDING
OWNER APPROVAL.
THE SITEWORK CONTRACTOR SHALL BRING SANITARY
SEWER SERVICE TO THIS LOCATION.
SEE SITE DRAWINGS FOR CONTINUATION.
THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL SANITARY SEWER PIPING TO THIS POINT
FROM WITHIN THE BUILDING AND FROM THE OIL
INTERCEPTOR AND SHALL MAKE FINAL CONNECTION
TO THE SANITARY SEWER SERVICE AT THIS LOCATION.
OI
1
4" CO
6"6" SAN. 6" SAN.
4" CO
4'-0"
MIN
.
6" SAN 6" SAN
ZURN Z886-HD-DGC
6-1/4" WIDE REVEAL TRENCH DRAIN
(2) 80" SECTIONS. INSTALL w/ RUNNING TRAP
4" S
AN
4" S
AN
FD-1
4"
TR
EN
CH
D
RA
IN
S
LO
PE
TR
EN
CH
D
RA
IN
S
LO
PE
4" S
AN
4" CO
TR
EN
CH
D
RA
IN
S
LO
PE
TR
EN
CH
D
RA
IN
S
LO
PE
6" S
AN
6"
FD-1
4"
4" S
AN
4"
4"
4" CO
KEEP 4" SANITARY SEWER WITHIN 16"
OF EAST SIDE OF MASONRY WALL
1'-4"
4"
4"
KEEP 4" SANITARY SEWER
WITHIN 16" OF EAST SIDE
OF MASONRY WALL
1'-4"
4"
4" CO
6" SAN.6"
FD-14"
4"
4"
4"
EXTEND 4" SANITARY
SEWER TO NORTH
END OF QUICK LUBE
BAY AS SHOWN
54" BRADLEY
SEMI-CIRCULAR
WASH BASIN
2" VENT UP
S
1
EMERGENCY
SHOWER & EYE
WASH STATION
EW
1
FD-1
4"
2"
39" x 39" x 6'-0" HIGH OWNER
FURNISHED PARTS CLEANER
FD-2
2"
LOW POINT OF
TRENCH DRAIN
HIGH POINT OF
TRENCH DRAIN
HIGH POINT OF
TRENCH DRAIN
FD-2
FD-2
2"
4"
2"
4"
4" CO
4" CO
TOP OF
FLOOR DRAIN
(-) 15-3/4"
ELEV. 98.68'
TOP OF
FLOOR DRAIN
(-) 15-3/4"
ELEV. 98.68'
TOP OF
FLOOR DRAIN
(-) 1"
ELEV. 99.91'
TOP OF FLOOR DRAIN (-) 1"
ELEV. 99.91'
TOP OF FLOOR DRAIN (-) 1"
ELEV. 99.91'
TOP OF FLOOR DRAIN (-) 1"
ELEV. 99.92'
TOP OF FLOOR DRAINS IN MEN 108
AND WOMEN 109 (-) 1/2"
ELEV. 99.96'
TOP OF
FLOOR DRAIN
(-) 1/2"
ELEV. 99.96'
FD-2
FD-2
2
"
FD-2
4"
4" S
AN
ZURN Z882-HD-DGC
12" WIDE REVEAL TRENCH DRAIN
(4) 96" SECTIONS. INSTALL w/ RUNNING TRAP
ZURN Z886-HD-DGC
6-1/4" WIDE REVEAL TRENCH DRAIN
(2) 80" SECTIONS. INSTALL w/ RUNNING TRAP
ZURN Z882-HD-DGC
12" WIDE REVEAL TRENCH DRAIN
(2) 96" SECTIONS. INSTALL w/ RUNNING TRAP
ZURN Z886-HD-DGC
6-1/4" WIDE REVEAL TRENCH DRAIN
(2) 80" SECTIONS.
INSTALL w/ RUNNING TRAP
ZURN Z886-HD-DGC
6-1/4" WIDE REVEAL TRENCH DRAIN
(2) 80" SECTIONS. INSTALL w/ RUNNING TRAP
6"S
TO
RM
6" S
TO
RM
8" S
TO
RM
1
0
"
S
T
O
R
M
8" S
TO
RM
ZURN Z886-HD-DGC
6-1/4" WIDE REVEAL TRENCH DRAIN
(3) 80" SECTIONS.
INSTALL w/ RUNNING TRAP
2" UP
TO FD-2
2" UP
TO FD-2
2"
2" DN2" DN
1-1/2" VENT
UP
(TYP. ALL
S3 SINKS)
S
3
TYP. (3)
2"
4"
3"v
2"
2"
2"
2"v
2" VENT UP
S
2
FD-2
1-1/2"
VENT UP
4"
4"
4"
4" CO
2"
2"
2"
2"
U
2
TYP. (3)
2" VENT UP
(TYP. @ U2)
FD-2
WC
4
TYP. (2)
WC
3
2" VENT UP
(TYP. @ ALL WC's)
3" VENT
UP TO 2ND
FLOOR
2
"
v
3"v
KS
2
2"
4"
1-1/2" v
6" S
AN
FD-2
2
"
1-1/2"
VENT UP
2"
2
"
2
"
6" S
AN
2
"
2
"
2
"
2" VENT UP
(TYP. @ U1)
1-1/2" VENT UP
(TYP. @ L1 SINKS)
4"
FD-2
2"
FD-2
2"
2
"
2
"
2
"
4" 4"
4" WALL CO
@ 24" AFF.
4"
4"
4"
2"
4" SAN
2"
1-1/2" VENT UP
(TYP. @ L1 SINKS)
1-1/2"
VENT UP
2" VENT UP
4" CO
2"
2" VENT
UP
2"
4"
4"
1-1/2"v
2"
4" UP
4" UP TO WC
2" UP TO FD-2
2" UP TO SHOWER
2" UP TO SINK
2"
3" VENT UP
2"v
FD-2
2"
TOP OF FLOOR DRAINS IN TECH TOILET 155
AND TECH SHOWER 157 (-) 1/2"
ELEV. 99.96'
TOP OF FLOOR DRAINS IN
MEN 128 AND WOMEN 129
(-) 1/2" ELEV. 99.96'
4" VENT UP TO
SECOND FLOOR
6" S
T
PC TO EXTEND STORM WATER PIPING TO
5'-0" BEYOND FOUNDATION WALL.
CONTINUATION BY SITEWORK CONTRACTOR.
SEE SITE DRAWINGS FOR CONTINUATION.
6" UP TO
ROOF DRAIN
6" UP TO
ROOF DRAIN
PC TO EXTEND STORM WATER PIPING TO
5'-0" BEYOND FOUNDATION WALL.
CONTINUATION BY SITEWORK CONTRACTOR.
SEE SITE DRAWINGS FOR CONTINUATION.
6" STORM WATER UP.
PC TO WRAP VERTICAL LEADER w/
6" F.G. INSUL. FOR SOUND CONTROL
4" STORM WATER UP.
PC TO WRAP VERTICAL LEADER w/
6" F.G. INSUL. FOR SOUND CONTROL
6" 6"
2
"
v
6 " STORM WATER
RISER UP
6" CO
PC TO EXTEND STORM WATER PIPING TO
5'-0" BEYOND FOUNDATION WALL.
CONTINUATION BY SITEWORK CONTRACTOR.
SEE SITE DRAWINGS FOR CONTINUATION.
DF
2
DF
1
KS
1
1-1/2" VENT UP
1-1/2"v
1-1/2" VENT UP
HC
WC
1
WC
2
TYP. (4)
U
1
TYP. (3)
L
1
TYP. (3)
TYP. (2)
L
1
TYP. (3)
2" VENT UP
3"v
2"v
2"v
1-1/2"v
6"
2"v
1-1/2"v
2"v
WH
1
4"
2" VENT UP
3" VENT UP
4"VTR
4"
2" VENT UP
4"
FD-2
2
"
2" VENT UP
2"
2"
2"
1-1/2"
VENT UP
1-1/2"
VENT UP
1-1/2"
VENT UP
2"
2"
2"
3"v3"v3"v
2"v
WC
1
WC
1
WC
4
U
2
S
3
S
2
WH
3
L
4
L
4
6" STORM
WATER UP
6"
6" ST
6" CO
6" CO 4" CO
6" STORM WATER UP.
PC TO WRAP VERTICAL LEADER w/
6" F.G. INSUL. FOR SOUND CONTROL
4"
CO
4"
UNDERGROUND
STORM WATER
PIPING BY SITEWORK
CONTRACTOR.
SEE SITE DRAWINGS
FOR CONTINUATION.
6"
6"
6"
6"
6"
6"
6"
6"
6"
10" STORM
8" S
TO
RM
6" S
TO
RM
6" S
TO
RM
8" S
TO
RM
6" S
TO
RM
4" CO
4" CO
UNDERGROUND
STORM WATER
PIPING BY SITEWORK
CONTRACTOR.
UNDERGROUND STORM WATER PIPING
BY SITEWORK CONTRACTOR.
SEE SITE DRAWINGS FOR CONTINUATION.
UNDERGROUND
STORM WATER
PIPING BY SITEWORK
CONTRACTOR.
YD-1
4"
2" VENT UP
4" SAN. UP
4" DN FROM CO
2"
4" CO
2" UP TO FD-2
2"
4"
2" VENT UP
2"
2"
SIDEWALL
VENT CAP
WC
3
L
3
U
2
1-1/2"
VENT UP
2"
4"
L
4
TRENCH DRAIN SLOPE
800 GALLON HEAVY DUTY PRECAST TANK AS
MANUFACTURED BY HIGHLAND TANK & MFG. CO.
ALTERNATE MANUFACTURERS ARE
ACCEPTABLE PENDING OWNER APPROVAL.
S
2
1-1/2" VENT
2
"
U
1
2"
1-1/2"
VENT UP
DF
1
HC
1-1/2" D.W.
CONNECTION
2"
2"
4"
4"
6" STORM
FROM ABOVE
4" CO
6"
2"
NOTE:
PC TO FURNISH & INSTALL SUMP PUMP
@ ELEVATOR SUMP PIT AND PIPE TO
4" SANITARY SEWER.
PC TO EXTEND STORM WATER PIPING TO 5'-0"
BEYOND FOUNDATION WALL. CONTINUATION
SHALL BE BY THE SITEWORK CONTRACTOR.
SEE SITE DRAWINGS FOR CONTINUATION.
PC TO EXTEND STORM WATER PIPING TO 5'-0"
BEYOND FOUNDATION WALL. CONTINUATION
SHALL BE BY THE SITEWORK CONTRACTOR.
SEE SITE DRAWINGS FOR CONTINUATION.
4'-0"
2" UP
TO FS-1
2"
1. PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO INSTALL COMPLETE
OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND
AS REQUIRED BY CODE.
2.
CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC, PLUMBING, AND
FIRE PROTECTION) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND
GENERAL ARRANGEMENT ONLY.
3. INSTALL ALL PLUMBING EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH
MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE
CODES AND REGULATIONS.
PLUMBING GENERAL NOTES
4. THE LOCATION OF EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE
WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PAY FOR
AND REPAIR ALL DAMAGES CAUSED BY FAILURE TO EXACTLY LOCATE AND PRESERVE
ANY AND ALL UNDERGROUND UTILITIES UNLESS OTHERWISE INDICATED.
5. COORDINATE CONSTRUCTION OF ALL PLUMBING WORK WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, ELECTRICAL WORK, ETC., SHOWN ON OTHER CONTRACT
DRAWINGS.
6.
MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, DUCTS,
CONDUITS, SUSPENDED EQUIPMENT, ETC., THROUGHOUT ACCESS ROUTES IN
MECHANICAL ROOMS.
7. ALL TESTS SHALL BE COMPLETED BEFORE ANY PLUMBING EQUIPMENT OR PIPING
INSULATION IS APPLIED.
8.
COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED
DRAWINGS. COORDINATE AND PROVIDE ALL PIPING TRANSITIONS REQUIRED FOR
FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND
COORDINATE ALL PIPING DIMENSIONS BEFORE FABRICATION.
9.
CONCRETE HOUSEKEEPING PADS TO SUIT PLUMBING EQUIPMENT SHALL BE SIZED
AND LOCATED BY THE P.C. MINIMUM THICKNESS SHALL BE 4 INCHES. PADS SHALL
EXTEND BEYOND THE EQUIPMENT A MINIMUM OF 3 INCHES ON EACH SIDE. PADS
SHALL BE PROVIDED BY THE P.C.
10. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE
SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE
APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST
CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS
AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED.
11. ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND AS
SHOWN IN DETAILS FOR PIPING AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL
BE FURNISHED AND INSTALLED BY THE P.C.
12. ALL PIPING AND EQUIPMENT SUPPORTED FROM THE STRUCTURE SHALL BE
COORDINATED WITH THE G.C. ALL ATTACHMENTS TO STEEL BAR JOISTS, TRUSSES,
OR JOIST GIRDERS SHALL BE AT PANEL POINTS. PROVIDE BEAM CLAMPS MEETING
MSS STANDARDS. WELDING TO STRUCTURAL MEMBERS SHALL NOT BE PERMITTED.
13. PROVIDE AND INSTALL ACCESS PANELS FOR INSTALLATION IN WALLS AND CEILINGS,
WHERE REQUIRED, TO SERVICE VALVES AND OTHER CONCEALED MECHANICAL
EQUIPMENT.
14. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE
COORDINATED WITH ALL OTHER TRADES INVOLVED.
15. ALL OPENINGS IN FIRE WALLS DUE TO PIPING, CONDUIT, ETC., SHALL BE FIRE
STOPPED WITH A PRODUCT SIMILAR TO 3M OR APPROVED EQUAL.
16. COORDINATE SCHEDULE FOR HOOKUPS TO EXISTING SYSTEMS AND EQUIPMENT
REMOVAL OR RELOCATION WITH THE OWNER AND PERFORM THIS WORK AT SUCH
TIMES TO ENSURE THAT PERIODS OF SHUTDOWN WILL BE ACCEPTABLE TO THE
OWNER.
17.VERIFY EXACT LOCATIONS OF CONNECTION POINTS (NEW TO EXISTING) IN FIELD
PRIOR TO CONSTRUCTION.
18.RELOCATE EXISTING PIPING IN EXISTING CEILING SPACES TO ACCOMMODATE ALL
RENOVATIONS AND ADDITIONS.
- SANITARY VENT PIPING
- SANITARY SEWER PIPING
- DOMESTIC HOT WATER
- DOMESTIC COLD WATER
- GAS COCK
- NATURAL GAS PIPING
SYMBOL LEGEND
1.
PLUMBING PIPING NOTES
2.
3.
UNLESS OTHERWISE NOTED, ALL WATER PIPING IS OVERHEAD, TIGHT TO UNDERSIDE
OF STRUCTURE OR SLAB, WITH SPACE FOR INSULATION IF REQUIRED.
4.
INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND
OTHER APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.
5.
ALL VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN SERVICE WHEN
EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF VALVE IS REMOVED.
6.
7.
8.
9.
10.ALL PIPING WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN
PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO COST TO THE OWNER.
RUN ALL SOIL WASTE AND VENT PIPING WITH 2% MINIMUM GRADE UNLESS
OTHERWISE NOTED. HORIZONTAL VENT PIPING SHALL BE GRADED TO DRIP BACK TO
THE SOIL OR WASTE PIPE BY GRAVITY.
PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING SYSTEM BRANCHES IN
WHICH BRANCH PIPING SERVES TWO OR MORE FIXTURES.
UNLESS NOTED OTHERWISE, ALL DOMESTIC COLD AND HOT WATER PIPING SHALL BE
1/2" SIZE.
PROVIDE ALL PLUMBING FIXTURES AND EQUIPMENT WITH ACCESSIBLE STOPS.
UNLESS NOTED OTHERWISE, DRAINS SHALL BE INSTALLED AT LOW POINTS OF ROOFS,
AREAWAYS, FLOORS, ETC.
PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE SYSTEMS AT ENDS OF
RUNS, AT CHANGES IN DIRECTION, NEAR THE BASE OF STACKS, EVERY 100 FEET IN
HORIZONTAL RUNS AND ELSEWHERE AS INDICATED.
- COMPRESSED AIR PIPING
AutoCAD SHX TextREGISTERED
AutoCAD SHX TextPROFESSIONAL
AutoCAD SHX TextENGINEER
AutoCAD SHX TextC
AutoCAD SHX TextO
AutoCAD SHX TextM
AutoCAD SHX TextM
AutoCAD SHX TextO
AutoCAD SHX TextN
AutoCAD SHX TextW
AutoCAD SHX TextE
AutoCAD SHX TextA
AutoCAD SHX TextL
AutoCAD SHX TextT
AutoCAD SHX TextH
AutoCAD SHX TextO
AutoCAD SHX TextF
AutoCAD SHX TextP
AutoCAD SHX TextE
AutoCAD SHX TextN
AutoCAD SHX TextN
AutoCAD SHX TextS
AutoCAD SHX TextY
AutoCAD SHX TextL
AutoCAD SHX TextV
AutoCAD SHX TextA
AutoCAD SHX TextN
AutoCAD SHX TextI
AutoCAD SHX TextA
AutoCAD SHX TextPE060405
AutoCAD SHX TextMATTHEW JON VERTUCCI
De
scrip
tio
n
RE
VIS
IO
NS
:
Da
te
SHEET : P1.1
Scale: As Noted
FIRST FLOOR SANITARY
SEWER ENLARGED PLANS
SANITARY SEWER PIPING
ENLARGED PLAN @ MEN'S TOILET 128, WOMEN'S TOILET 129 & HOSPITALITY 131
Scale: 3/16" = 1'-0"
TYPICAL ADA ACCESSORY MOUNTING HEIGHTS
Scale: None
SANITARY SEWER PIPING
ENLARGED PLAN @ TECH TOILET 155 AND TECH LUNCH 158
Scale: 3/16" = 1'-0"
Checked By: MJV
Drawn By: JP
Designed By: JP
MA
TT
HE
W J. V
ER
TU
CC
I
PA
. L
IC
. N
O. P
E-0
60
40
5
Ve
rte
ch
E
ng
in
ee
rin
g A
sso
cia
te
s
24
4 D
an
ville
R
oa
d
Blo
om
sb
urg
, P
en
nsylva
nia
1
78
15
Ph
on
e: (5
70
) 4
37
-2
10
0
Fa
x: (5
70
) 4
37
-3
10
0
NE
W C
HE
VR
OL
ET
/ V
OL
VO
D
EA
LE
RS
HIP
F
OR
:
Gre
en
ca
stle
, P
en
nsylva
nia
An
trim
T
ow
nsh
ip
, F
ra
nklin
C
ou
nty
AL
EX
AN
DE
R F
AM
IL
Y D
EA
LE
RS
HIP
S
BA
M Jo
b #
: 2
00
0
SANITARY SEWER PIPING
ENLARGED PLAN @ MEN 108, WOMEN 109 AND TECH TOILET 112
Scale: 3/16" = 1'-0"
Date: August 1, 2016
EN
GIN
EE
R
06
07
UP
MEN
128
WOMEN
129
RETAIL
PARTS
130
HOSPITALITY
131
CHILDREN
133CUST. LOUNGE
132
CORRIDOR
126
FILES
127
SERVICE MGR.
125
STORAGE 141
STAIR
#1
HC
HC
HC
HC HC
2
"
2
"
2
"
6" S
AN
2
"
2
"
2
"
2" VENT UP
(TYP. @ U1)
1-1/2" VENT UP
(TYP. @ L1 SINKS)
4"
FD-2
2"
FD-2
2"
2
"
2
"
2
"
4" 4"
4" WALL CO
@ 24" AFF.
4"
4"
4"
2"
1-1/2" VENT UP
(TYP. @ L1 SINKS)
TOP OF FLOOR DRAINS IN
MEN 128 AND WOMEN 129
(-) 1/2" ELEV. 99.96'
4" VENT UP TO
SECOND FLOOR
DF
1
KS
1
1-1/2" VENT UP
1-1
/2
"v
1-1/2" VENT UP
HC
WC
1
WC
2
TYP. (4)
U
1
TYP. (3)
L
1
TYP. (3)
TYP. (2)
L
1
TYP. (3)
2" VENT UP
3"v
2"v
2"v
1-1
/2
"v
6"
2"v
1-1
/2
"v
2"v
6" STORM
WATER UP
6"
6" ST
6" STORM WATER UP.
PC TO WRAP VERTICAL LEADER w/
6" F.G. INSUL. FOR SOUND CONTROL
2" VENT UP
4" SAN. UP
4" DN FROM CO
2"
- SANITARY VENT PIPING
- SANITARY SEWER PIPING
- DOMESTIC HOT WATER
- DOMESTIC COLD WATER
- GAS COCK
- NATURAL GAS PIPING
SYMBOL LEGEND
1. PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO INSTALL COMPLETE
OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND
AS REQUIRED BY CODE.
2.
CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC, PLUMBING, AND
FIRE PROTECTION) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND
GENERAL ARRANGEMENT ONLY.
3. INSTALL ALL PLUMBING EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH
MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE
CODES AND REGULATIONS.
PLUMBING GENERAL NOTES
4. THE LOCATION OF EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE
WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PAY FOR
AND REPAIR ALL DAMAGES CAUSED BY FAILURE TO EXACTLY LOCATE AND PRESERVE
ANY AND ALL UNDERGROUND UTILITIES UNLESS OTHERWISE INDICATED.
5. COORDINATE CONSTRUCTION OF ALL PLUMBING WORK WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, ELECTRICAL WORK, ETC., SHOWN ON OTHER CONTRACT
DRAWINGS.
6.
MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, DUCTS,
CONDUITS, SUSPENDED EQUIPMENT, ETC., THROUGHOUT ACCESS ROUTES IN
MECHANICAL ROOMS.
7. ALL TESTS SHALL BE COMPLETED BEFORE ANY PLUMBING EQUIPMENT OR PIPING
INSULATION IS APPLIED.
8.
COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED
DRAWINGS. COORDINATE AND PROVIDE ALL PIPING TRANSITIONS REQUIRED FOR
FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND
COORDINATE ALL PIPING DIMENSIONS BEFORE FABRICATION.
9.
CONCRETE HOUSEKEEPING PADS TO SUIT PLUMBING EQUIPMENT SHALL BE SIZED
AND LOCATED BY THE P.C. MINIMUM THICKNESS SHALL BE 4 INCHES. PADS SHALL
EXTEND BEYOND THE EQUIPMENT A MINIMUM OF 3 INCHES ON EACH SIDE. PADS
SHALL BE PROVIDED BY THE P.C.
10. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE
SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE
APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST
CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS
AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED.
11. ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND AS
SHOWN IN DETAILS FOR PIPING AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL
BE FURNISHED AND INSTALLED BY THE P.C.
12. ALL PIPING AND EQUIPMENT SUPPORTED FROM THE STRUCTURE SHALL BE
COORDINATED WITH THE G.C. ALL ATTACHMENTS TO STEEL BAR JOISTS, TRUSSES,
OR JOIST GIRDERS SHALL BE AT PANEL POINTS. PROVIDE BEAM CLAMPS MEETING
MSS STANDARDS. WELDING TO STRUCTURAL MEMBERS SHALL NOT BE PERMITTED.
13. PROVIDE AND INSTALL ACCESS PANELS FOR INSTALLATION IN WALLS AND CEILINGS,
WHERE REQUIRED, TO SERVICE VALVES AND OTHER CONCEALED MECHANICAL
EQUIPMENT.
14. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE
COORDINATED WITH ALL OTHER TRADES INVOLVED.
15. ALL OPENINGS IN FIRE WALLS DUE TO PIPING, CONDUIT, ETC., SHALL BE FIRE
STOPPED WITH A PRODUCT SIMILAR TO 3M OR APPROVED EQUAL.
16. COORDINATE SCHEDULE FOR HOOKUPS TO EXISTING SYSTEMS AND EQUIPMENT
REMOVAL OR RELOCATION WITH THE OWNER AND PERFORM THIS WORK AT SUCH
TIMES TO ENSURE THAT PERIODS OF SHUTDOWN WILL BE ACCEPTABLE TO THE
OWNER.
17.VERIFY EXACT LOCATIONS OF CONNECTION POINTS (NEW TO EXISTING) IN FIELD
PRIOR TO CONSTRUCTION.
18.RELOCATE EXISTING PIPING IN EXISTING CEILING SPACES TO ACCOMMODATE ALL
RENOVATIONS AND ADDITIONS.
1.
PLUMBING PIPING NOTES
2.
3.
UNLESS OTHERWISE NOTED, ALL WATER PIPING IS OVERHEAD, TIGHT TO UNDERSIDE
OF STRUCTURE OR SLAB, WITH SPACE FOR INSULATION IF REQUIRED.
4.
INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND
OTHER APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.
5.
ALL VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN SERVICE WHEN
EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF VALVE IS REMOVED.
6.
7.
8.
9.
10.ALL PIPING WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN
PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO COST TO THE OWNER.
RUN ALL SOIL WASTE AND VENT PIPING WITH 2% MINIMUM GRADE UNLESS
OTHERWISE NOTED. HORIZONTAL VENT PIPING SHALL BE GRADED TO DRIP BACK TO
THE SOIL OR WASTE PIPE BY GRAVITY.
PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING SYSTEM BRANCHES IN
WHICH BRANCH PIPING SERVES TWO OR MORE FIXTURES.
UNLESS NOTED OTHERWISE, ALL DOMESTIC COLD AND HOT WATER PIPING SHALL BE
1/2" SIZE.
PROVIDE ALL PLUMBING FIXTURES AND EQUIPMENT WITH ACCESSIBLE STOPS.
UNLESS NOTED OTHERWISE, DRAINS SHALL BE INSTALLED AT LOW POINTS OF ROOFS,
AREAWAYS, FLOORS, ETC.
PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE SYSTEMS AT ENDS OF
RUNS, AT CHANGES IN DIRECTION, NEAR THE BASE OF STACKS, EVERY 100 FEET IN
HORIZONTAL RUNS AND ELSEWHERE AS INDICATED.
- COMPRESSED AIR PIPING
MODELSYMBOL
L-1
MFG.
PLUMBING FIXTURE SCHEDULE
REMARKSHWCW W
RIM
HGT
VENT
34"DF-1 ELKAY 1/2" - - - 1-1/2"2"ADA DOUBLE WALL HUNG WATER COOLER, BARRIER FREE ACCESS, 370 WATTS, 4.0 F.L.A.
AMERICAN
STANDARD
U-2
AMERICAN
STANDARD
3/4" 2"- - - 2" 17"
1.0 GPF WALL MOUNTED URINAL, SUBSTITUTE FLUSH VALVE w/ SLOAN ROYAL MODEL 186 FLUSH VALVE,
WITH JR SMITH CARRIER S0617
1/2" 2"1/2"
FD-1 ZURN Z415B - - - - - - - - - 4" FLOOR DRAIN w/ PROSET TRAP GUARD TG34IP OR TRAP PRIMER AS PER LOCAL AUTHORITY- - -
HB-1 ZURN Z1320-C - - - - - - - - - LOCKABLE WALL MOUNTED FROST PROOF HOSE BIBB w/ INTEGRAL BACKFLOW PREVENTER- - -
- - -
3/4"
34"S-2 PROFLOW 1/2" 1/2" 2"
FLOOR MOUNTED LAUNDRY TUB WITH PROFLOW PFWSC1120CP 1.2 GPM, 2 HANDLE FAUCET, WITH
PROFLOW PFXCAZ32CL12 LAVATORY KIT
FLT2024
34"
COMBINATION DRENCH SHOWER / EYEWASH STATION, 15 MIN. DELIVERY OF TEMPERED WATER,
S19-2100 MIXING VALVE
- - - - - -1-1/4" - - - - - -
FD-2 ZURN Z415B - - - - - - - - -- - -- - - 2" FLOOR DRAIN w/ PROSET TRAP GUARD TG22IP OR TRAP PRIMER AS PER LOCAL AUTHORITY
1-1/2"
1-1/2"
EW-1 BRADLEY S19-310
WC-1
AMERICAN
STANDARD
MADERA ADA TOILET, ELONGATED BOWL, OPEN FRONT SEAT w/ SELECTRONIC FLUSH VALVE1" 4"- - - 17"2"3043.660
WC-2
AMERICAN
STANDARD
MADERA ELONGATED BOWL, OPEN FRONT SEAT w/ SELECTRONIC FLUSH VALVE1" 4"- - - 15"2"
WC-3 4"- - - 17"2"
WC-4 4"- - - 15"2"
AMERICAN
STANDARD
AMERICAN
STANDARD
3451.660
RP-1 TACO 007-F5 - - - - - - - - -- - -3/4"RECIRCULATING PUMP, 6 GPM, 8 FT. HEAD, 115 VOLT, 0.71 AMPS, QUANTITY 2
U-1
AMERICAN
STANDARD
3/4" 2"- - - 2" 14"
1.0 GPF ADA WALL MOUNTED URINAL w/ SELECTRONIC FLUSH VALVE, WITH JR SMITH CARRIER S06176501.610
6501.511
L-2
AMERICAN
STANDARD
1/2" 2"1/2"
ADA COMPLIANT SINGLE BOWL OVAL SINK w/ ADA WRAP KIT, CHICAGO C895317ABCP FAUCET & GRID
STRAINER
34"1-1/2"
CR25224
CR33223
ADA COMPLIANT SINGLE BOWL OVAL SINK w/ SLOAN S3315025 SENSOR FAUCET & GRID STRAINER
KS-1 ELKAY 1/2" 2"1/2" 2" 34" SINGLE BOWL SINK w/ DELTA FAUCET D400LFHDF w/ SPRAY
KS-2 ELKAY 1/2" 2"1/2" 2" 34" DOUBLE BOWL SINK w/ DELTA FAUCET D400LFHDF w/ SPRAY
34"DF-2 ELKAY 1/2" - - - 1-1/2"2"WALL HUNG WATER COOLER, BARRIER FREE ACCESS, 8 GPH, 370 WATTS, 4.0 F.L.A.
EZS8L
EZSTLR8C
0476028020
0475.047
SH-1 AQUATIC 1/2" 2"1/2" 2" - - -
36" x 36" FIBERGLASS SHOWER UNIT w/ DR-10000-IP DELTA SHOWER SYSTEM & T13220 SHOWER
TRIM w/ FACTORY INSTALLED GRAB BARS & BUILT-IN FOLD UP SEAT- (STD. COLOR OPTIONS)
A1363-BFSC
S-1
S-3 0355.012.020
34"1/2" 1/2" 2" 2"
34"1/2" 1/2" 2" 1-1/2"
BRADLEY
AMERICAN
STANDARD
54", 3.0 GPM BRADLEY BRADSTONE SEMI-CIRCULAR WASHFOUNTAIN
WALL MOUNTED SINK AT ADA HEIGHT W/ PROFLOW ADA WRAP KIT, CHICAGO C895317ABCP 2 HANDLE
FACUET & GRID STRAINER, JR SMITH S0710 CARRIER
U-3
AMERICAN
STANDARD
3/4" 2"- - - 2" 14"
1.0 GPF ADA WALL MOUNTED URINAL, SUBSTITUTE FLUSH VALVE w/ SLOAN ROYAL MODEL 186 FLUSH
VALVE, WITH JR SMITH CARRIER S0617
6501.511
L-3
AMERICAN
STANDARD
1/2" 2"1/2" 34"1-1/2"
HB-2 ZURN Z1341-BFP - - - - - - - - - WALL MOUNTED HOSE BIBB w/ INTEGRAL BACKFLOW PREVENTER- - -3/4"
ADA COMPLIANT SINGLE BOWL OVAL SINK w/ ADA WRAP KIT, CHICAGO C895317ABCP FAUCET & GRID
STRAINER
WF2804
3043.660
3451.660
1"
1"
ADA TOILET, ELONGATED BOWL, OPEN FRONT SEAT, SUBSTITUTE FLUSH VALVE WITH SLOAN ROYAL
MODEL 111 FLUSH VALVE
ELONGATED BOWL, OPEN FRONT SEAT, SUBSTITUTE FLUSH VALVE WITH SLOAN ROYAL MODEL 111
FLUSH VALVE
WH-1 1-1/2" - - - - - - - - -60 GALLON, 120,000 BTU GAS-FIRED WATER HEATER / w/ 3" VENT THRU SIDEWALL
AMERICAN 1-1/2"
WH-2 AMERICAN
WH-3 3/4" - - - - - - - - -AMERICAN 3/4"
HCG3-60T120-3P
WH-4
WH-5 3/4" - - - - - - - - -
WASHING MACHING BOX - 696 SERIES w/ DRAIN BOX - PLAIN VALVE w/o ARRESTER
AMERICAN 3/4"
696WB-1 1/2" 2" 1-1/2" - - -SIOUX CHIEF 1/2"
1-1/2" - - - - - - - - -60 GALLON, 120,000 BTU GAS-FIRED WATER HEATER / w/ 3" VENT THRU ROOF
1-1/2"HCG3-60T120-3P
LDCE31-20U
YD-1 1800 4" - - - - - -- - -- - -18x18 CATCH BASIN WITH GRATE IN CONCRETE AREA, NON TRAFFIC RATED
LDCE31-20U
19 GALLON,COMPACT COMMERCIAL ELECTRIC WATER HEATER / 277 VOLT, 14.4 AMPS, 4 KW, 20.4 GPH
RECOVERY AT 80° RISE
K-2349-0L-4 KOHLER 1/2" 2"1/2" 2" 34"
WHITE CAMBER UNDERCOUNTER LAV. w/ TECHNICAL CONCEPTS VENETIAN DECK-MTD. AUTO FAUCET
TFG750269
NOTES: 1.
2. P.C. SHALL PROVIDE ALL FITTINGS & ACCESSORIES THAT ARE LEAD LAW COMPLIANT.
P.C. SHALL PROVIDE WATER TEMPERATURE LIMITING DEVICE PER ASSE 1070 AS REQUIRED TO PROVIDE MAXIMUM 110°F HOT WATER TO ALL PUBLIC SINKS.
OI-1 SIZING: 6 CF (FIRST 100 SF) + 346 CF (1 CF/100 SF) = 352 CF X 7.5 GAL./CF = 2,643 GALLONS CAPACITY REQUIRED. 3,000 GALLON CAPACITY SPECIFIED.3.
OI-1
HIGHLAND
TANK
- - - - - - -- - -- - - 6"
OIL/WATER SEPARATOR, 3,000 GALLON CAPACITY, INSTALLED PER MANUFACTURER'S INSTRUCTIONS
AND SEWER AUTHORITY REQUIREMENTS, WITH HEAVY DUTY MANHOLE FRAME & COVER
NDS, INC.
19 GALLON,COMPACT COMMERCIAL ELECTRIC WATER HEATER / 277 VOLT, 14.4 AMPS, 4 KW, 20.4 GPH
RECOVERY AT 80° RISE
1-1/4" - - - - - - - - -
ELECTRIC TANKLESS WATER HEATER / 480 VOLT, 96 AMPS FOR EMERGENCY SHOWER
1-1/4"ED079480T12 EFD
AMERICAN 1-1/2" - - - - - - - - -60 GALLON, 120,000 BTU GAS-FIRED WATER HEATER / w/ 4" VENT THRU SIDEWALL
1-1/2"HCG3-60T120-3P
WH-6 AMERICAN
GAS-FIRED WATER HEATERS SHALL INCLUDE GAS PRESSURE REGULATOR INSTALLED PER MANUFACTURER'S INSTRUCTIONS TO REDUCE PRESSURE FROM 2 PSI
TO 4.4" - 14" W.G. RANGE.
4.
0476028020
FS-1 ZURN FD2375 2" - - - - - -- - -- - -
12x12 FLOOR SINK 6" DEEP, w/ ANTI-SPLASH DOME & STRAINER, w/ PROSET TRAP GUARD TG22IP OR TRAP
PRIMER AS PER LOCAL AUTHORITY
36
" M
AX
.
SP
OU
T
OU
TL
ET
38
" M
IN
.
43
" M
AX
.
34
"
T.O
. R
IM
34
"
T.O
. R
IM
4" M
IN
.
RO
BE
H
OO
K
TO
IL
ET
T
IS
SU
E
DIS
PE
NS
ER
(D
OU
BL
E)
TO
IL
ET
T
IS
SU
E
DIS
PE
NS
ER
(S
IN
GL
E)
FE
M. N
AP
KIN
DIS
PE
NS
ER
FE
M. N
AP
KIN
DIS
PO
SA
L
PA
PE
R T
OW
EL
DIS
PE
NS
ER
/D
IS
PO
SA
L
PA
PE
R T
OW
EL
DIS
PE
NS
ER
WA
ST
E
RE
CE
PT
AC
LE
LIQ
UID
S
OA
P
DIS
PE
NS
ER
MO
P / B
RO
OM
R
AC
K
SH
OW
ER
C
UR
TA
IN
R
OD
SO
AP
D
IS
H
SO
AP
D
IS
PE
NS
ER
MIR
RO
R w
/ S
IN
K
OR
C
OU
NT
ER
ME
TA
L S
HE
LF
TO
WE
L B
AR
SH
OW
ER
S
EA
T
MIR
RO
R w
/ N
O S
IN
K
OR
C
OU
NT
ER
BA
BY
C
HA
NG
IN
G
ST
AT
IO
N
TO
IL
ET
S
EA
T
CO
VE
R D
IS
PE
NS
ER
WA
LL
H
UN
G
TO
IL
ET
DIS
PE
NS
ER
LO
CA
TIO
N
FL
OO
R M
OU
NT
TO
IL
ET
UR
IN
AL
CO
UN
TE
R M
OU
NT
LA
VA
TO
RY
WA
LL
M
OU
NT
LA
VA
TO
RY
EL
EC
TR
IC
W
AT
ER
CO
OL
ER
VERTICAL GRAB
BAR FOR PUBLIC
RESPROOMS ONLY
VERTICAL GRAB
BAR FOR PUBLIC
RESPROOMS ONLY
AC
CE
SS
IB
LE
ADA
WRAP
ADA
WRAP
ST
AN
DIN
G
PE
RS
ON
S
℄
℄
℄
℄
℄ ℄
℄
℄
℄
℄
48
"
19
"
18
"
42
"
TO
C
OIN
S
LO
T
48
" T
O
TO
WE
L S
LO
T
48
" T
O
TO
WE
L S
LO
T
36
" T
O
OP
EN
IN
G
60
"
78
"
42
"
40
"
40
"
OP
ER
AB
LE
PO
RT
IO
N
40
" T
O
BO
TT
OM
O
F
RE
FL
EC
TIV
E
SU
RF
AC
E
35
" T
O
BO
TT
OM
O
F
RE
FL
EC
TIV
E
SU
RF
AC
E
40
"
TO
T
OP
48
"
19
"
48
"
TO
S
LO
T
48
" T
O
HIG
HE
ST
OP
ER
AB
LE
PO
SIT
IO
N
℄
℄
6"
36"
MINIMUM
19
"
18"
12"
42"
MIN.
18
"
MIN
.3
9" - 4
1"
33
" - 3
6"
19
"
39" - 41"
15
"
MIN
.
7"-9"
1-1
/2
" M
IN
.
DIS
PE
NS
ER
LO
CA
TIO
N
℄ 15"
MIN
.
7"-9"
1-1
/2
" M
IN
.
6"36" MIN.
18"
17
"-1
9"
17
"-1
9"
33
"-3
6"
39
"-4
1"
18
"
MIN
.
42"
MIN.12"
39"-41"
17
"
27
"
MIN
.
UP
09
08
10
HC
BE
NC
H
HCHC
TECH TLT.
155
TECH LUNCH
158
TECH
LOCKER
156
TECH
SHOWER
157
HC
HC
HC
HC
1-1/2" VENT
UP
(TYP. ALL
S3 SINKS)
S
3
TYP. (3)
2"
4"
3"v
2"
2"
2"
2"v
2" VENT UP
S
2
FD-2
1-1/2"
VENT UP
4"
4"
4"
4" CO
2"
2"
2"
2"
U
2
TYP. (3)
2" VENT UP
(TYP. @ U2)
FD-2
WC
4
TYP. (2)
WC
3
2" VENT UP
(TYP. @ ALL WC's)
3" VENT
UP TO 2ND
FLOOR
2
"
v
3"v
KS
2
2"
4"
1-1
/2
" v
1-1/2"
VENT UP
2"
FD-2
2"
TOP OF FLOOR DRAINS IN TECH TOILET 155
AND TECH SHOWER 157 (-) 1/2"
ELEV. 99.96'
2
"
v
DF
2
WH
1
04
02
03
TECH. TLT. 112
SERVICE WRITE-UP
SERVICE MGR.
113
MEN 108
WOMEN
109
JAN.
110
CHILDREN
111
SERVICE LANES
HC
HC
SALES 107
DW
TOP OF FLOOR DRAINS IN MEN 108
AND WOMEN 109 (-) 1/2"
ELEV. 99.96'
TOP OF
FLOOR DRAIN
(-) 1/2"
ELEV. 99.96'
FD-2
FD-2
2
"
FD-2
4"
4"
2" VENT UP
3" VENT UP
4"VTR
4"
2" VENT UP
4"
FD-2
2
"
2" VENT UP
2"
2"
2"
1-1/2"
VENT UP
1-1/2"
VENT UP
1-1/2"
VENT UP
2"
2"
2"
3"v3"v3"v
2"v
WC
1
WC
1
WC
4
U
2
S
3
S
2
WH
3
L
4
L
4
1-1/2"
VENT UP
2"
4"
L
4
U
1
2"
1-1/2"
VENT UP
DF
1
HC
1-1/2" D.W.
CONNECTION
2"
2"
4"
AutoCAD SHX TextREGISTERED
AutoCAD SHX TextPROFESSIONAL
AutoCAD SHX TextENGINEER
AutoCAD SHX TextC
AutoCAD SHX TextO
AutoCAD SHX TextM
AutoCAD SHX TextM
AutoCAD SHX TextO
AutoCAD SHX TextN
AutoCAD SHX TextW
AutoCAD SHX TextE
AutoCAD SHX TextA
AutoCAD SHX TextL
AutoCAD SHX TextT
AutoCAD SHX TextH
AutoCAD SHX TextO
AutoCAD SHX TextF
AutoCAD SHX TextP
AutoCAD SHX TextE
AutoCAD SHX TextN
AutoCAD SHX TextN
AutoCAD SHX TextS
AutoCAD SHX TextY
AutoCAD SHX TextL
AutoCAD SHX TextV
AutoCAD SHX TextA
AutoCAD SHX TextN
AutoCAD SHX TextI
AutoCAD SHX TextA
AutoCAD SHX TextPE060405
AutoCAD SHX TextMATTHEW JON VERTUCCI
De
scrip
tio
n
RE
VIS
IO
NS
:
Da
te
SHEET : P2.0
Scale: As Noted
SECOND FLOOR SANITARY
SEWER & STORM WATER
& SPECIFICATIONS
SECOND FLOOR SANITARY SEWER
AND STORM WATER PIPING PLAN
Scale: 3/32" = 1'-0"
Checked By: MJV
Drawn By: JP
Designed By: JP
MA
TT
HE
W J. V
ER
TU
CC
I
PA
. L
IC
. N
O. P
E-0
60
40
5
Ve
rte
ch
E
ng
in
ee
rin
g A
sso
cia
te
s
24
4 D
an
ville
R
oa
d
Blo
om
sb
urg
, P
en
nsylva
nia
1
78
15
Ph
on
e: (5
70
) 4
37
-2
10
0
Fa
x: (5
70
) 4
37
-3
10
0
NE
W C
HE
VR
OL
ET
/ V
OL
VO
D
EA
LE
RS
HIP
F
OR
:
Gre
en
ca
stle
, P
en
nsylva
nia
An
trim
T
ow
nsh
ip
, F
ra
nklin
C
ou
nty
AL
EX
AN
DE
R F
AM
IL
Y D
EA
LE
RS
HIP
S
BA
M Jo
b #
: 2
00
0
Date: August 1, 2016
EN
GIN
EE
R
A2
A
A1
FIRE SEPARATION LEGEND
- 1 HOUR SEPARATION
- 2 HOUR SEPARATION
DN
3x5 DS
3x5 DS
3x5 DS
SERVICE LANES
BELOW
STAIR
#1
ELEV.
VOLVO
SHOWROOM
BELOW
VOLVO
LOW ROOF
VOLVO
PARTS STORAGE
200
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
AA
COMPRESSOR
ROOM
202
CTB500
WASTE OIL BOILER
1600#
B-1
CTB500
WASTE OIL BOILER
1600#
B-2
CO
MP
RE
SS
OR
BA
CK
-U
P
CO
MP
RE
SS
OR
CHEVROLET
SHOWROOM
BELOW
VESTIBULE
BELOW
DN
DN
STAIR
#2
DN
PARTS
STORAGE
204
BUSINESS OFFICE
226
WOMEN
213
WORKOUT
ROOM
209
ELEV.
LOBBY
206
CORRIDOR
207
CORRIDOR
223
OFFICE
220
DEALER OFFICE
205
OFFICE
222
JAN.
217
STORAGE
219
OFFICE
224
CORRIDOR
212
FILE ROOM
225
CO
RR
ID
OR
21
0
LUNCH
ROOM
211
MEZZANINE
203
OFFICE
221
TRAINING
ROOM
208
CONTRLR.
227
IT ROOM
218
EN
TR
Y R
OO
F
BE
LO
W
LO
WE
R C
EIL
IN
G
OV
ER
L
IV
IN
G R
OO
M
DEALER TOILET
205a
HC
HC
HC
HC
HC
HC
SHOWER
216
SHOWER
214
MECHANICAL
MEZZANINE
201
NORTHNORTH
MEN
215
JANITOR
205b
2x4 DS
6" RD 6" RD
2" VENT DN
2"v
RUN VENT PIPING A MINIMUM OF 18'-0"
ABOVE FINISHED FLOOR TO LOWEST POINT
OF 2" VENT PIPE.
SIDEWALL
VENT CAP
6" UP TO
ROOF DRAIN
6" STORM
WATER DOWN
6" UP TO
ROOF DRAIN
6" ST6" ST
6" UP TO
ROOF DRAIN
6" STORM
WATER DN
6" UP TO
ROOF
DRAIN
FD-2
TOP OF FLOOR DRAIN (-) 0"
ELEV. 112.84'
FD-2
TOP OF FLOOR DRAIN (-) 0"
ELEV. 112.84'
4" SAN. DN
3" VENT UP / 4" VTR
2" DN
1-1/2" VENT UP
1-1/2"v
2" DN
2" VENT UP
2"v
3" VENT DN
TOP OF FLOOR DRAIN @
JANITOR 217 (-) 0"
ELEV. 112.34'
TOP OF ALL FLOOR
DRAINS THIS AREA
(-) 1/2" (U.N.O.)
ELEV. 112.30'
FD-2
TOP OF FLOOR DRAIN (-) 1/2"
ELEV. 112.30'
4" STORM
WATER DOWN
4" UP TO
ROOF DRAIN
4" S
T
3" VENT DN
L
3
SH
1
WC
3
4" VENT DN
3" VENT UP
4" VTR
3"v
4"v4" VTR
WH
2
6" STORM
WATER DN
6" S
T
2" VENT DN
3" VENT UP / 4" VTR
KS
2
WC
4
WC
3
S
3
SH
1
SH
1
L
2
TYP. (2)
S
2
FD-2
FD-2
FD-2
HC
2"
2"
2"
2"
1-1/2"
VENT UP
2
"1-1/2"
VENT UP
2" VENT
UP
U
3
1-1/2" VENT UP
(TYP. @ L2 SINKS)
4"
WC
4
4"
2" VENT UP
WC
3
4"
4" CO
4"
2"
2"
3"
4"
2"v
2"v
3"v
2"v
4" CO
4
"
1-1/2"
VENT UP
2"
4" SAN.
DN
2"
3"v
2"v
1-1/2"v
2"
1-1/2"
VENT UP
DF
2
1-1/2"v
FD-2
2
"
FD-2
2"
2"
4"
2" VENT UP
(TYP. @ ALL SH-1
SHOWERS)
2
"
2" VENT UP
2"
25
EF
1130 CFM
GRV
3
GRV
7
RTU
12
7-1/2 TON
SLO
PE
- 1/4:12
SLO
PE
- 1/4:12
4" VTR
WH
5
WH
4
RTU
7
12-1/2 TON
6" STORM
WATER DOWN
6" UP TO
ROOF DRAIN
6" ST
HORIZONTAL ROOF DRAIN PIPING SHALL BE
INSULATED (TYP. ALL ROOF DRAINS)
DIVISION 22 00 00 - PLUMBING SPECIFICATIONS
PART 1 - GENERAL REQUIREMENTS
1. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF PLUMBING SYSTEMS AND EQUIPMENT.
2. FURNISH AND INSTALL PLUMBING SYSTEMS COMPLETE AND OPERATIONAL. THE SCOPE OF PLUMBING WORK SHALL
INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES AND IN PERFORMING
ALL OPERATIONS NECESSARY FOR AND REASONABLY INCIDENTAL TO THE INSTALLATION OF ALL PLUMBING SYSTEMS AS
INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN.
3. ALL PLUMBING WORK SHALL BE IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL PLUMBING
CODE AND ALL APPLICABLE STATE AND LOCAL CODES AND REGULATIONS.
4. THE PLUMBING CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE. THE CONTRACTOR SHALL
VERIFY THE CONNECTION REQUIREMENTS AND THE CONFIGURATIONS OF PLUMBING EQUIPMENT BEFORE INSTALLATION.
5. EQUIPMENT AND MATERIAL SHOWN ON DRAWINGS ARE BASED ON MANUFACTURER'S PUBLISHED DATA AND ARE, IN THE
DESIGNER'S PROFESSIONAL OPINION, REPRESENTATIVE OF TYPICAL SIZES. ALL EQUIPMENT AND MATERIAL PROVIDED SHALL
FIT WITHIN THE SPACE PROVIDED. ALL EQUIPMENT, FIXTURES AND SERVICEABLE DEVICES SHALL BE INSTALLED WITH ACCESS
AND CLEARANCE FOR MAINTENANCE. COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES TO PROVIDE THIS
ACCESS AND CLEARANCE. INSTALL ALL EQUIPMENT AND MATERIALS PER MANUFACTURER'S INSTRUCTIONS.
6. IF EQUIPMENT, FIXTURES AND MATERIAL OTHER THAN THAT SCHEDULED OR SPECIFIED IS APPROVED AND PROVIDED, IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE AND PROVIDE REVISED UTILITIES AND SERVICE CONNECTIONS
AND VERIFY THE SPACE ALLOTTED FOR ADEQUACY AND CLEARANCE REQUIREMENTS. THIS INCLUDES BUT IS NOT LIMITED
TO REVISED POWER, WATER, WASTE DRAINS, FUEL FLUES AND VENT REQUIREMENTS.
7. COORDINATE ALL LOCATIONS AND SIZE OF STRUCTURAL FLOOR AND WALL PENETRATIONS WITH THE GENERAL CONTRACTOR
AND PROVIDE CODE REQUIRED SEALS AT ALL FIRE-RATED WALL, CEILING, ROOF AND FLOOR PENETRATIONS.
8. ACCESS DOORS AND/OR PANELS SHALL BE PROVIDED AT ALL MAINTENANCE AND SERVICE LOCATIONS FOR CONCEALED
CONTROL DEVICES, VALVES AND PLUMBING EQUIPMENT/DEVICES. UNLESS A SIZE IS SPECIFICALLY NOTED, PANELS SHALL
BE SIZED TO SERVICE EQUIPMENT/DEVICE. DOORS AND PANELS SHALL HAVE THE SAME FIRE RATING AS THE WALL OR
CEILING IN WHICH THEY ARE INSTALLED. ACCESS DOORS AND/OR PANELS ARE NOT REQUIRED WHERE ADJUSTMENT,
MAINTENANCE AND REPLACEMENT ARE POSSIBLE THROUGH LAY-IN SUSPENDED CEILING.
9. AT THE COMPLETION OF THE WORK AND PRIOR TO THE FINAL ACCEPTANCE, ALL PARTS OF THE WORK SHALL BE
THOROUGHLY CLEANED.
10. ELEVATIONS LISTED FOR ALL PLUMBING SYSTEM PIPING IN THE CONTRACT DOCUMENTS ARE TO BE VERIFIED PRIOR TO
CONSTRUCTION AGAINST EXISTING CONDITIONS, UTILITIES AND NEW CONSTRUCTION. ALL SLOPED PLUMBING SYSTEMS SHALL
HAVE RIGHT OF WAY OVER ALL OTHER BUILDING SYSTEM COMPONENTS.
11. ALL EXISTING BUILDING AND SITE FEATURES NOT BEING ALTERED BY THIS PROJECT ARE TO BE PROTECTED FROM DAMAGE.
CONTRACTOR SHALL REPAIR ALL DAMAGE OCCURRING TO EXISTING CONSTRUCTION CAUSED BY THE CONTRACTOR'S OPERATIONS
AT HIS/HER EXPENSE TO THE COMPLETE SATISFACTION OF THE OWNER.
12. ALL PENETRATIONS THROUGH THE WALLS AND CEILINGS SHOULD BE CAULKED REGARDLESS OF WHETHER OR NOT THEY ARE
FIRE RATED. THIS IS FOR ACOUSTICAL SEPARATION.
13. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING ASSOCIATED WITH THE PLUMBING
SCOPE OF WORK.
14. NOT ALL SYMBOLS AND ABBREVIATIONS ON THIS LEGEND APPLY TO THIS PROJECT.
PART 2 - PIPING
1. SOIL, WASTE AND VENT PIPING SHALL BE PVC SCHEDULE 40 PIPE WITH SOLVENT WELDED
2. DOMESTIC HOT AND COLD WATER PIPING:
A. ABOVE GROUND DOMESTIC HOT AND COLD WATER:
1) COPPER PIPING
SHALL BE TYPE L HARD COPPER WITH LEAD-FREE SOLDER FITTINGS. PROVIDE 3/8" CLOSED CELL ELASTOMERIC PIPE
INSULATION ARMSTRONG ARAMFLEX II, ON ALL DOMESTIC HOT AND COLD WATER PIPING, THAT IS LOCATED IN EXTERIOR
BUILDING WALLS OR AREAS, SUBJECT TO FREEZING TEMPERATURES.
2) PEX PIPING
SHALL BE VANGUARD PEX, ZURN PEX OR EQUIVALENT. PEX TO BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATION.
COLD WATER LINES TO RUN FROM PEX MANIFOLD DIRECTLY TO EACH FIXTURE. HOT WATER LINES TO RUN FROM PEX
MANIFOLD DIRECTLY TO EACH FIXTURE. EACH COLD AND HOT WATER LINE TO FEED ONE FIXTURE ONLY UNLESS OTHERWISE
NOTED ON PLANS.
B. UNDERGROUND DOMESTIC HOT AND COLD WATER:
1) COPPER PIPING
SHALL BE TYPE K HARD COPPER.
2) PEX PIPING
SHALL BE VANGUARD PEX, ZURN PEX OR EQUIVALENT. PEX TO BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATION.
3. MINIMUM PITCH OF HORIZONTAL DRAINAGE BRANCHES AND SEWER PIPES SHALL BE ¼" PER LINEAR FOOT FOR 2 ½" OR LESS,
1/8" PER LINEAR FOOT FOR 3" TO 6", AND 1/16" PER LINEAR FOOT FOR 8" OR LARGER.
4. ROUGH-IN PIPING SHALL BE TESTED AND APPROVED BEFORE CLOSING IN WITH OTHER WORK.
5. WATER AND SEWER LINES SHALL CONNECT TO RESPECTIVE MAINS. PERFORM ALL WORK REQUIRED FOR PROPER CONNECTIONS IN
STRICT ACCORDANCE WITH REQUIREMENTS OF LOCAL SEWER AND WATER AUTHORITIES.
6. MAINTAIN MINIMUM 10' HORIZONTAL SEPARATION BETWEEN WATER SERVICE PIPING AND BUILDING SEWER. WHERE WATER SERVICE
PIPE AND BUILDING SEWER ARE LOCATED IN THE SAME TRENCH, WATER LINE SHALL BE INSTALLED A MINIMUM OF 18" ABOVE THE
TOP OF THE HIGHEST POINT OF THE BUILDING SEWER AND INSTALLED ON A SOLID SHELF AT ONE SIDE OF THE TRENCH.
WATER SERVICE LINE SHALL BE A MINIMUM OF 4' BELOW GRADE. BUILDING SEWER SHALL BE A MINIMUM OF 4' BELOW GRADE.
7. VENT LINES SHALL TERMINATE 12" ABOVE ROOF.
8. DISINFECTION OF POTABLE WATER SYSTEM SHALL BE AS FOLLOWS:
A. THE PIPE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL DIRTY WATER DOES NOT APPEAR AT THE POINTS
OF OUTLET.
B. THE SYSTEM OR PART THEREOF SHALL BE FILLED WITH A WATER/CHLORINE SOLUTION CONTAINING AT LEAST 50 PARTS PER
MILLION OF CHLORINE, AND THE SYSTEM SHALL BE VALVED OFF AND ALLOWED TO STAND FOR 24 HOURS; OR THE SYSTEM
OR PART THEREOF SHALL BE FILLED WITH A WATER/CHLORINE SOLUTION CONTAINING AT LEAST 200 PARTS PER MILLION OF
CHLORINE AND ALLOWED TO STAND FOR 3 HOURS.
C. FOLLOWING THE REQUIRED STANDING TIME, THE SYSTEM SHALL BE FLUSHED WITH CLEAN POTABLE WATER UNTIL THE CHLORINE
IS PURGED FROM THE SYSTEM.
D. THE PROCEDURE SHALL BE REPEATED IF A BACTERIOLOGICAL EXAMINATION SHOWS THAT CONTAMINATION REMAINS PRESENT
IN THE SYSTEM.
E. AT THE TIME OF FINAL INSPECTION AND PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY, A DISINFECTION POTABLE WATER
REPORT SHALL BE SUBMITTED TO CENTRE REGION CODE ADMINISTRATION; REPORT SHALL INDICATE BACTERIOLOGICAL AND
CHLORINE COUNT SATISFIES DEP REQUIREMENTS.
9. FULL OPEN VALVES SHALL BE INSTALLED ON WATER SUPPLY PIPING.
10. INSTALL SHUT-OFF VALVES AT EACH FIXTURE. INSTALL BRANCH SHUTOFF VALVES WHERE INDICATED ON PLANS. LOCATE AND
ORIENT VALVE OPERATORS FOR EASE OF ACCESS AND FULL LIMITS OF OPERATIONS.
11. INSULATION AND VAPOR BARRIER SHALL BE PROVIDED ON ALL PIPING AND/OR EQUIPMENT SUBJECT TO HEAT LOSS, CONDENSATION
OR CONSTITUTING A POTENTIAL BURN HAZARD. PROVIDE 1" INSULATION ON ALL HORIZONTAL ROOF DRAIN PIPING.
12. INSULATION SHALL NOT BE CRUSHED OR COMPRESSED THROUGH INTERFERENCE WITH SYSTEMS INSTALLED BY OTHER TRADES OR
BUILDING CONSTRUCTION.
13. INSTALL PLUMBING AND PIPING HIGH POINTS AS TIGHT AS POSSIBLE TO THE BUILDING STRUCTURE TO ALLOW PROPER PITCH AND
MAXIMIZE CEILING HEIGHT.
14. PROVIDE AIR VENTS AT PIPING HIGH POINTS AND DRAINS AT LOW POINTS IN MAINS.
15. ALL PIPING SHALL BE INSTALLED IN SUCH A MANNER AS TO AVOID FREEZING.
16. ALL PIPING SHALL BE CONCEALED IN WALLS AND BEHIND FIXED FURNISHINGS UNLESS OTHERWISE INDICATED. EXPOSED PIPING IN
FINISHED AREAS SHALL BE CHROME PLATED WITH A CHROME-PLATED ESCUTCHEON AT EACH FINISHED ENTRY/EXIT.
17. ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LINES AND BE SUPPORTED AND ANCHORED AS REQUIRED TO FACILITATE EXPANSION
AND CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. INSTALL AS REQUIRED TO MEET ALL
CONSTRUCTION CONDITIONS AND TO ALLOW FOR INSTALLATION OF OTHER WORK INCLUDING DUCTS AND ELECTRICAL CONDUIT.
ALL PIPING EXPOSED TO VIEW SHALL BE ROUTED AS HIGH AS POSSIBLE AND TO THE UNDERSIDE OF STRUCTURE.
18. ACCESS SHALL BE PROVIDED TO ALL FULL OPEN AND SHUTOFF PIPING.
19. PROVIDE SHUTOFF VALVES ON ALL SUPPLY PIPING TO EACH PLUMBING FIXTURE, EQUIPMENT, AND APPLIANCES. PROVIDE EACH
PLUMBING FIXTURE WITH CHROME PLATED RIGID OR FLEXIBLE SUPPLIES, REDUCERS AND ESCUTCHEONS.
20. LOCATIONS OF FULL OPEN VALVES:
A. ON THE BUILDING WATER SERVICE PIPE FROM THE PUBLIC WATER SUPPLY NEAR THE CURB - EXISTING.
B. ON THE WATER DISTRIBUTION SUPPLY PIPE AT THE ENTRANCE INTO THE STRUCTURE - EXISTING.
C. ON THE DISCHARGE SIDE OF THE METER - EXISTING.
D. ON THE WATER SUPPLY PIPE TO EVERY WATER HEATER.
PART 3 - PRODUCTS
1. CLEANOUTS - PROVIDE CLEANOUTS AT THE END OF ALL SOIL AND WASTE LINES AND AT LOCATIONS AS REQUIRED BY CODE.
2. BACKFLOW - WATER SUPPLY CONNECTION REQUIRED TO BE PROTECTED WITH ASSE 1022 DEVICE.
A). BEVERAGE DISPENSING EQUIPMENT SHALL MEET THE REQUIREMENTS OF NSF18. WATER SUPPLY CONNECTION SHALL BE
PROTECTED BY BACKFLOW PREVENTER THAT MEETS ASSE 1022 OR BY AIR GAP. BEVERAGE DISPENSING EQUIPMENT
INSTALLATION INSTRUCTIONS SHALL BE ON SITE AT TIME OF INSPECTION.
B). COFFEE MACHINES & NON-CARBONATED BEVERAGE DISPENSERS CONNECTED TO THE WATER SUPPLY SHALL BE PROTECTED
BY BACKFLOW PREVENTER THAT MEETS ASSE 1022 OR BY AIR GAP. EQUIPMENT INSTALLATION INSTRUCTIONS SHALL BE ON
SITE AT TIME OF INSPECTION.
3. BACKWATER CHECK VALVE SHALL BE INSTALLED ON FIXTURES/DEVICES AS REQUIRED BY CODE AND AS SHOWN ON PLANS.
4. PLUMBING FIXTURES
A). PROVIDE PLUMBING FIXTURES AND TRIM AS INDICATED ON DRAWINGS, SPECIFICATIONS DOCUMENTS AND PLUMBING FIXTURE
SCHEDULE.
5. WATER HEATERS
A). PROVIDE WATER HEATERS AS SHOW ON PLANS.
B). WATER HEATERS SHALL BE DRAINED TO AN INDIRECT WASTE LINE OR TO TERMINATE NOT LESS THAN 12" OR MORE THAN
24" ABOVE GRADE.
C). WATER HEATER TO HAVE THERMAL EXPANSION TANKS, EQUAL TO THERM-X-TROL MODEL ST-12 (6.4 GALLON TOTAL VOLUME).
AutoCAD SHX TextREGISTERED
AutoCAD SHX TextPROFESSIONAL
AutoCAD SHX TextENGINEER
AutoCAD SHX TextC
AutoCAD SHX TextO
AutoCAD SHX TextM
AutoCAD SHX TextM
AutoCAD SHX TextO
AutoCAD SHX TextN
AutoCAD SHX TextW
AutoCAD SHX TextE
AutoCAD SHX TextA
AutoCAD SHX TextL
AutoCAD SHX TextT
AutoCAD SHX TextH
AutoCAD SHX TextO
AutoCAD SHX TextF
AutoCAD SHX TextP
AutoCAD SHX TextE
AutoCAD SHX TextN
AutoCAD SHX TextN
AutoCAD SHX TextS
AutoCAD SHX TextY
AutoCAD SHX TextL
AutoCAD SHX TextV
AutoCAD SHX TextA
AutoCAD SHX TextN
AutoCAD SHX TextI
AutoCAD SHX TextA
AutoCAD SHX TextPE060405
AutoCAD SHX TextMATTHEW JON VERTUCCI
De
scrip
tio
n
RE
VIS
IO
NS
:
Da
te
SHEET : P2.1
Scale: As Noted
SECOND FLOOR SANITARY
SEWER ENLARGED PLANS
SANITARY SEWER PIPING
ENLARGED PLAN @ WOMEN 213 & MEN 215 AND JANITOR 217
Scale: 3/16" = 1'-0"
TYPICAL ADA ACCESSORY MOUNTING HEIGHTS
Scale: None
SANITARY SEWER PIPING
ENLARGED PLAN @ DEALER TOILET 205a
Scale: 3/16" = 1'-0"
Checked By: MJV
Drawn By: JP
Designed By: JP
MA
TT
HE
W J. V
ER
TU
CC
I
PA
. L
IC
. N
O. P
E-0
60
40
5
Ve
rte
ch
E
ng
in
ee
rin
g A
sso
cia
te
s
24
4 D
an
ville
R
oa
d
Blo
om
sb
urg
, P
en
nsylva
nia
1
78
15
Ph
on
e: (5
70
) 4
37
-2
10
0
Fa
x: (5
70
) 4
37
-3
10
0
NE
W C
HE
VR
OL
ET
/ V
OL
VO
D
EA
LE
RS
HIP
F
OR
:
Gre
en
ca
stle
, P
en
nsylva
nia
An
trim
T
ow
nsh
ip
, F
ra
nklin
C
ou
nty
AL
EX
AN
DE
R F
AM
IL
Y D
EA
LE
RS
HIP
S
BA
M Jo
b #
: 2
00
0
Date: August 1, 2016
EN
GIN
EE
R
STAIR
#1
DN
WOMEN
213
JAN.
217
CORRIDOR
212
FILE ROOM
225
LUNCH
ROOM
211
TRAINING
ROOM
208
IT ROOM
218
HC
HC
HC
HC
HC
HC
SHOWER
216
SHOWER
214
MEN
215
6" UP TO
ROOF DRAIN
6" STORM
WATER DN
6" UP TO
ROOF
DRAIN
TOP OF FLOOR DRAIN @
JANITOR 217 (-) 0"
ELEV. 112.34'
TOP OF ALL FLOOR
DRAINS THIS AREA
(-) 1/2" (U.N.O.)
ELEV. 112.30'
WH
2
6" STORM
WATER DN
6" S
T
2" VENT DN
3" VENT UP / 4" VTR
KS
2
WC
4
WC
3
S
3
SH
1
SH
1
L
2
TYP. (2)
S
2
FD-2
FD-2
FD-2
HC
2"
2"
2"
2"
1-1/2"
VENT UP
2
"
1-1/2"
VENT UP
2" VENT
UP
U
3
1-1/2" VENT UP
(TYP. @ L2 SINKS)
4"
WC
4
4"
2" VENT UP
WC
3
4"
4" CO
4"
2"
2"
3"
4"
2"v
2"v
3"v
2"v
4" CO
4
"
1-1/2"
VENT UP
2"
4" SAN.
DN
2"
3"v
2"v
1-1
/2
"v
2"
1-1/2"
VENT UP
DF
2
1-1
/2
"v
FD-2
2
"
FD-2
2"
2"
4"
2" VENT UP
(TYP. @ ALL SH-1
SHOWERS)
2
"
2" VENT UP
2"
MODELSYMBOL
L-1
MFG.
PLUMBING FIXTURE SCHEDULE
REMARKSHWCW W
RIM
HGT
VENT
34"DF-1 ELKAY 1/2" - - - 1-1/2"2"ADA DOUBLE WALL HUNG WATER COOLER, BARRIER FREE ACCESS, 370 WATTS, 4.0 F.L.A.
AMERICAN
STANDARD
U-2
AMERICAN
STANDARD
3/4" 2"- - - 2" 17"
1.0 GPF WALL MOUNTED URINAL, SUBSTITUTE FLUSH VALVE w/ SLOAN ROYAL MODEL 186 FLUSH VALVE,
WITH JR SMITH CARRIER S0617
1/2" 2"1/2"
FD-1 ZURN Z415B - - - - - - - - - 4" FLOOR DRAIN w/ PROSET TRAP GUARD TG34IP OR TRAP PRIMER AS PER LOCAL AUTHORITY- - -
HB-1 ZURN Z1320-C - - - - - - - - - LOCKABLE WALL MOUNTED FROST PROOF HOSE BIBB w/ INTEGRAL BACKFLOW PREVENTER- - -
- - -
3/4"
34"S-2 PROFLOW 1/2" 1/2" 2"
FLOOR MOUNTED LAUNDRY TUB WITH PROFLOW PFWSC1120CP 1.2 GPM, 2 HANDLE FAUCET, WITH
PROFLOW PFXCAZ32CL12 LAVATORY KIT
FLT2024
34"
COMBINATION DRENCH SHOWER / EYEWASH STATION, 15 MIN. DELIVERY OF TEMPERED WATER,
S19-2100 MIXING VALVE
- - - - - -1-1/4" - - - - - -
FD-2 ZURN Z415B - - - - - - - - -- - -- - - 2" FLOOR DRAIN w/ PROSET TRAP GUARD TG22IP OR TRAP PRIMER AS PER LOCAL AUTHORITY
1-1/2"
1-1/2"
EW-1 BRADLEY S19-310
WC-1
AMERICAN
STANDARD
MADERA ADA TOILET, ELONGATED BOWL, OPEN FRONT SEAT w/ SELECTRONIC FLUSH VALVE1" 4"- - - 17"2"3043.660
WC-2
AMERICAN
STANDARD
MADERA ELONGATED BOWL, OPEN FRONT SEAT w/ SELECTRONIC FLUSH VALVE1" 4"- - - 15"2"
WC-3 4"- - - 17"2"
WC-4 4"- - - 15"2"
AMERICAN
STANDARD
AMERICAN
STANDARD
3451.660
RP-1 TACO 007-F5 - - - - - - - - -- - -3/4"RECIRCULATING PUMP, 6 GPM, 8 FT. HEAD, 115 VOLT, 0.71 AMPS, QUANTITY 2
U-1
AMERICAN
STANDARD
3/4" 2"- - - 2" 14"
1.0 GPF ADA WALL MOUNTED URINAL w/ SELECTRONIC FLUSH VALVE, WITH JR SMITH CARRIER S06176501.610
6501.511
L-2
AMERICAN
STANDARD
1/2" 2"1/2"
ADA COMPLIANT SINGLE BOWL OVAL SINK w/ ADA WRAP KIT, CHICAGO C895317ABCP FAUCET & GRID
STRAINER
34"1-1/2"
CR25224
CR33223
ADA COMPLIANT SINGLE BOWL OVAL SINK w/ SLOAN S3315025 SENSOR FAUCET & GRID STRAINER
KS-1 ELKAY 1/2" 2"1/2" 2" 34" SINGLE BOWL SINK w/ DELTA FAUCET D400LFHDF w/ SPRAY
KS-2 ELKAY 1/2" 2"1/2" 2" 34" DOUBLE BOWL SINK w/ DELTA FAUCET D400LFHDF w/ SPRAY
34"DF-2 ELKAY 1/2" - - - 1-1/2"2"WALL HUNG WATER COOLER, BARRIER FREE ACCESS, 8 GPH, 370 WATTS, 4.0 F.L.A.
EZS8L
EZSTLR8C
0476028020
0475.047
SH-1 AQUATIC 1/2" 2"1/2" 2" - - -
36" x 36" FIBERGLASS SHOWER UNIT w/ DR-10000-IP DELTA SHOWER SYSTEM & T13220 SHOWER
TRIM w/ FACTORY INSTALLED GRAB BARS & BUILT-IN FOLD UP SEAT- (STD. COLOR OPTIONS)
A1363-BFSC
S-1
S-3 0355.012.020
34"1/2" 1/2" 2" 2"
34"1/2" 1/2" 2" 1-1/2"
BRADLEY
AMERICAN
STANDARD
54", 3.0 GPM BRADLEY BRADSTONE SEMI-CIRCULAR WASHFOUNTAIN
WALL MOUNTED SINK AT ADA HEIGHT W/ PROFLOW ADA WRAP KIT, CHICAGO C895317ABCP 2 HANDLE
FACUET & GRID STRAINER, JR SMITH S0710 CARRIER
U-3
AMERICAN
STANDARD
3/4" 2"- - - 2" 14"
1.0 GPF ADA WALL MOUNTED URINAL, SUBSTITUTE FLUSH VALVE w/ SLOAN ROYAL MODEL 186 FLUSH
VALVE, WITH JR SMITH CARRIER S0617
6501.511
L-3
AMERICAN
STANDARD
1/2" 2"1/2" 34"1-1/2"
HB-2 ZURN Z1341-BFP - - - - - - - - - WALL MOUNTED HOSE BIBB w/ INTEGRAL BACKFLOW PREVENTER- - -3/4"
ADA COMPLIANT SINGLE BOWL OVAL SINK w/ ADA WRAP KIT, CHICAGO C895317ABCP FAUCET & GRID
STRAINER
WF2804
3043.660
3451.660
1"
1"
ADA TOILET, ELONGATED BOWL, OPEN FRONT SEAT, SUBSTITUTE FLUSH VALVE WITH SLOAN ROYAL
MODEL 111 FLUSH VALVE
ELONGATED BOWL, OPEN FRONT SEAT, SUBSTITUTE FLUSH VALVE WITH SLOAN ROYAL MODEL 111
FLUSH VALVE
WH-1 1-1/2" - - - - - - - - -60 GALLON, 120,000 BTU GAS-FIRED WATER HEATER / w/ 3" VENT THRU SIDEWALL
AMERICAN 1-1/2"
WH-2 AMERICAN
WH-3 3/4" - - - - - - - - -AMERICAN 3/4"
HCG3-60T120-3P
WH-4
WH-5 3/4" - - - - - - - - -
WASHING MACHING BOX - 696 SERIES w/ DRAIN BOX - PLAIN VALVE w/o ARRESTER
AMERICAN 3/4"
696WB-1 1/2" 2" 1-1/2" - - -SIOUX CHIEF 1/2"
1-1/2" - - - - - - - - -60 GALLON, 120,000 BTU GAS-FIRED WATER HEATER / w/ 3" VENT THRU ROOF
1-1/2"HCG3-60T120-3P
LDCE31-20U
YD-1 1800 4" - - - - - -- - -- - -18x18 CATCH BASIN WITH GRATE IN CONCRETE AREA, NON TRAFFIC RATED
LDCE31-20U
19 GALLON,COMPACT COMMERCIAL ELECTRIC WATER HEATER / 277 VOLT, 14.4 AMPS, 4 KW, 20.4 GPH
RECOVERY AT 80° RISE
K-2349-0L-4 KOHLER 1/2" 2"1/2" 2" 34"
WHITE CAMBER UNDERCOUNTER LAV. w/ TECHNICAL CONCEPTS VENETIAN DECK-MTD. AUTO FAUCET
TFG750269
NOTES: 1.
2. P.C. SHALL PROVIDE ALL FITTINGS & ACCESSORIES THAT ARE LEAD LAW COMPLIANT.
P.C. SHALL PROVIDE WATER TEMPERATURE LIMITING DEVICE PER ASSE 1070 AS REQUIRED TO PROVIDE MAXIMUM 110°F HOT WATER TO ALL PUBLIC SINKS.
OI-1 SIZING: 6 CF (FIRST 100 SF) + 346 CF (1 CF/100 SF) = 352 CF X 7.5 GAL./CF = 2,643 GALLONS CAPACITY REQUIRED. 3,000 GALLON CAPACITY SPECIFIED.3.
OI-1
HIGHLAND
TANK
- - - - - - -- - -- - - 6"
OIL/WATER SEPARATOR, 3,000 GALLON CAPACITY, INSTALLED PER MANUFACTURER'S INSTRUCTIONS
AND SEWER AUTHORITY REQUIREMENTS, WITH HEAVY DUTY MANHOLE FRAME & COVER
NDS, INC.
19 GALLON,COMPACT COMMERCIAL ELECTRIC WATER HEATER / 277 VOLT, 14.4 AMPS, 4 KW, 20.4 GPH
RECOVERY AT 80° RISE
1-1/4" - - - - - - - - -
ELECTRIC TANKLESS WATER HEATER / 480 VOLT, 96 AMPS FOR EMERGENCY SHOWER
1-1/4"ED079480T12 EFD
AMERICAN 1-1/2" - - - - - - - - -60 GALLON, 120,000 BTU GAS-FIRED WATER HEATER / w/ 4" VENT THRU SIDEWALL
1-1/2"HCG3-60T120-3P
WH-6 AMERICAN
GAS-FIRED WATER HEATERS SHALL INCLUDE GAS PRESSURE REGULATOR INSTALLED PER MANUFACTURER'S INSTRUCTIONS TO REDUCE PRESSURE FROM 2 PSI
TO 4.4" - 14" W.G. RANGE.
4.
0476028020
FS-1 ZURN FD2375 2" - - - - - -- - -- - -
12x12 FLOOR SINK 6" DEEP, w/ ANTI-SPLASH DOME & STRAINER, w/ PROSET TRAP GUARD TG22IP OR TRAP
PRIMER AS PER LOCAL AUTHORITY
36
" M
AX
.
SP
OU
T
OU
TL
ET
38
" M
IN
.
43
" M
AX
.
34
"
T.O
. R
IM
34
"
T.O
. R
IM
4" M
IN
.
RO
BE
H
OO
K
TO
IL
ET
T
IS
SU
E
DIS
PE
NS
ER
(D
OU
BL
E)
TO
IL
ET
T
IS
SU
E
DIS
PE
NS
ER
(S
IN
GL
E)
FE
M. N
AP
KIN
DIS
PE
NS
ER
FE
M. N
AP
KIN
DIS
PO
SA
L
PA
PE
R T
OW
EL
DIS
PE
NS
ER
/D
IS
PO
SA
L
PA
PE
R T
OW
EL
DIS
PE
NS
ER
WA
ST
E
RE
CE
PT
AC
LE
LIQ
UID
S
OA
P
DIS
PE
NS
ER
MO
P / B
RO
OM
R
AC
K
SH
OW
ER
C
UR
TA
IN
R
OD
SO
AP
D
IS
H
SO
AP
D
IS
PE
NS
ER
MIR
RO
R w
/ S
IN
K
OR
C
OU
NT
ER
ME
TA
L S
HE
LF
TO
WE
L B
AR
SH
OW
ER
S
EA
T
MIR
RO
R w
/ N
O S
IN
K
OR
C
OU
NT
ER
BA
BY
C
HA
NG
IN
G
ST
AT
IO
N
TO
IL
ET
S
EA
T
CO
VE
R D
IS
PE
NS
ER
WA
LL
H
UN
G
TO
IL
ET
DIS
PE
NS
ER
LO
CA
TIO
N
FL
OO
R M
OU
NT
TO
IL
ET
UR
IN
AL
CO
UN
TE
R M
OU
NT
LA
VA
TO
RY
WA
LL M
OU
NT
LA
VA
TO
RY
EL
EC
TR
IC
W
AT
ER
CO
OL
ER
VERTICAL GRAB
BAR FOR PUBLIC
RESPROOMS ONLY
VERTICAL GRAB
BAR FOR PUBLIC
RESPROOMS ONLY
AC
CE
SS
IB
LE
ADA
WRAP
ADA
WRAP
ST
AN
DIN
G
PE
RS
ON
S
℄
℄
℄
℄
℄ ℄
℄
℄
℄
℄
48
"
19
"
18
"
42
"
TO
C
OIN
S
LO
T
48
" T
O
TO
WE
L S
LO
T
48
" T
O
TO
WE
L S
LO
T
36
" T
O
OP
EN
IN
G
60
"
78
"
42
"
40
"
40
"
OP
ER
AB
LE
PO
RT
IO
N
40
" T
O
BO
TT
OM
O
F
RE
FL
EC
TIV
E
SU
RF
AC
E
35
" T
O
BO
TT
OM
O
F
RE
FL
EC
TIV
E
SU
RF
AC
E
40
"
TO
T
OP
48
"
19
"
48
"
TO
S
LO
T
48
" T
O
HIG
HE
ST
OP
ER
AB
LE
PO
SIT
IO
N
℄
℄
6"
36"
MINIMUM
19
"
18"
12"
42"
MIN.
18
"
MIN
.3
9" - 4
1"
33
" - 3
6"
19
"
39" - 41"
15
"
MIN
.
7"-9"
1-1
/2
" M
IN
.
DIS
PE
NS
ER
LO
CA
TIO
N
℄ 15"
MIN
.
7"-9"
1-1
/2
" M
IN
.
6"36" MIN.
18"
17
"-1
9"
17
"-1
9"
33
"-3
6"
39
"-4
1"
18
"
MIN
.
42"
MIN.12"
39"-41"
17
"
27
"
MIN
.
ELEV.
STAIR
#2
DN
ELEV.
LOBBY
206
CORRIDOR
207
DEALER OFFICE
205
DEALER TOILET
205a
JANITOR
205b
6" STORM
WATER DOWN
6" UP TO
ROOF DRAIN
6" ST6" ST
4" SAN. DN
3" VENT UP / 4" VTR
2" DN
1-1/2" VENT UP
1-1
/2
"v
2" DN
2" VENT UP
2"v
3" VENT DN
FD-2
TOP OF FLOOR DRAIN (-) 1/2"
ELEV. 112.30'
L
3
SH
1
WC
3
WH
5
1. PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO INSTALL COMPLETE
OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND
AS REQUIRED BY CODE.
2.
CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC, PLUMBING, AND
FIRE PROTECTION) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND
GENERAL ARRANGEMENT ONLY.
3. INSTALL ALL PLUMBING EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH
MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE
CODES AND REGULATIONS.
PLUMBING GENERAL NOTES
4. THE LOCATION OF EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE
WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PAY FOR
AND REPAIR ALL DAMAGES CAUSED BY FAILURE TO EXACTLY LOCATE AND PRESERVE
ANY AND ALL UNDERGROUND UTILITIES UNLESS OTHERWISE INDICATED.
5. COORDINATE CONSTRUCTION OF ALL PLUMBING WORK WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, ELECTRICAL WORK, ETC., SHOWN ON OTHER CONTRACT
DRAWINGS.
6.
MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, DUCTS,
CONDUITS, SUSPENDED EQUIPMENT, ETC., THROUGHOUT ACCESS ROUTES IN
MECHANICAL ROOMS.
7. ALL TESTS SHALL BE COMPLETED BEFORE ANY PLUMBING EQUIPMENT OR PIPING
INSULATION IS APPLIED.
8.
COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED
DRAWINGS. COORDINATE AND PROVIDE ALL PIPING TRANSITIONS REQUIRED FOR
FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND
COORDINATE ALL PIPING DIMENSIONS BEFORE FABRICATION.
9.
CONCRETE HOUSEKEEPING PADS TO SUIT PLUMBING EQUIPMENT SHALL BE SIZED
AND LOCATED BY THE P.C. MINIMUM THICKNESS SHALL BE 4 INCHES. PADS SHALL
EXTEND BEYOND THE EQUIPMENT A MINIMUM OF 3 INCHES ON EACH SIDE. PADS
SHALL BE PROVIDED BY THE P.C.
10. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE
SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE
APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST
CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS
AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED.
11. ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND AS
SHOWN IN DETAILS FOR PIPING AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL
BE FURNISHED AND INSTALLED BY THE P.C.
12. ALL PIPING AND EQUIPMENT SUPPORTED FROM THE STRUCTURE SHALL BE
COORDINATED WITH THE G.C. ALL ATTACHMENTS TO STEEL BAR JOISTS, TRUSSES,
OR JOIST GIRDERS SHALL BE AT PANEL POINTS. PROVIDE BEAM CLAMPS MEETING
MSS STANDARDS. WELDING TO STRUCTURAL MEMBERS SHALL NOT BE PERMITTED.
13. PROVIDE AND INSTALL ACCESS PANELS FOR INSTALLATION IN WALLS AND CEILINGS,
WHERE REQUIRED, TO SERVICE VALVES AND OTHER CONCEALED MECHANICAL
EQUIPMENT.
14. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE
COORDINATED WITH ALL OTHER TRADES INVOLVED.
15. ALL OPENINGS IN FIRE WALLS DUE TO PIPING, CONDUIT, ETC., SHALL BE FIRE
STOPPED WITH A PRODUCT SIMILAR TO 3M OR APPROVED EQUAL.
16. COORDINATE SCHEDULE FOR HOOKUPS TO EXISTING SYSTEMS AND EQUIPMENT
REMOVAL OR RELOCATION WITH THE OWNER AND PERFORM THIS WORK AT SUCH
TIMES TO ENSURE THAT PERIODS OF SHUTDOWN WILL BE ACCEPTABLE TO THE
OWNER.
17.VERIFY EXACT LOCATIONS OF CONNECTION POINTS (NEW TO EXISTING) IN FIELD
PRIOR TO CONSTRUCTION.
18.RELOCATE EXISTING PIPING IN EXISTING CEILING SPACES TO ACCOMMODATE ALL
RENOVATIONS AND ADDITIONS.
- SANITARY VENT PIPING
- SANITARY SEWER PIPING
- DOMESTIC HOT WATER
- DOMESTIC COLD WATER
- GAS COCK
- NATURAL GAS PIPING
SYMBOL LEGEND
1.
PLUMBING PIPING NOTES
2.
3.
UNLESS OTHERWISE NOTED, ALL WATER PIPING IS OVERHEAD, TIGHT TO UNDERSIDE
OF STRUCTURE OR SLAB, WITH SPACE FOR INSULATION IF REQUIRED.
4.
INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND
OTHER APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.
5.
ALL VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN SERVICE WHEN
EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF VALVE IS REMOVED.
6.
7.
8.
9.
10.ALL PIPING WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN
PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO COST TO THE OWNER.
RUN ALL SOIL WASTE AND VENT PIPING WITH 2% MINIMUM GRADE UNLESS
OTHERWISE NOTED. HORIZONTAL VENT PIPING SHALL BE GRADED TO DRIP BACK TO
THE SOIL OR WASTE PIPE BY GRAVITY.
PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING SYSTEM BRANCHES IN
WHICH BRANCH PIPING SERVES TWO OR MORE FIXTURES.
UNLESS NOTED OTHERWISE, ALL DOMESTIC COLD AND HOT WATER PIPING SHALL BE
1/2" SIZE.
PROVIDE ALL PLUMBING FIXTURES AND EQUIPMENT WITH ACCESSIBLE STOPS.
UNLESS NOTED OTHERWISE, DRAINS SHALL BE INSTALLED AT LOW POINTS OF ROOFS,
AREAWAYS, FLOORS, ETC.
PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE SYSTEMS AT ENDS OF
RUNS, AT CHANGES IN DIRECTION, NEAR THE BASE OF STACKS, EVERY 100 FEET IN
HORIZONTAL RUNS AND ELSEWHERE AS INDICATED.
- COMPRESSED AIR PIPING
AutoCAD SHX TextREGISTERED
AutoCAD SHX TextPROFESSIONAL
AutoCAD SHX TextENGINEER
AutoCAD SHX TextC
AutoCAD SHX TextO
AutoCAD SHX TextM
AutoCAD SHX TextM
AutoCAD SHX TextO
AutoCAD SHX TextN
AutoCAD SHX TextW
AutoCAD SHX TextE
AutoCAD SHX TextA
AutoCAD SHX TextL
AutoCAD SHX TextT
AutoCAD SHX TextH
AutoCAD SHX TextO
AutoCAD SHX TextF
AutoCAD SHX TextP
AutoCAD SHX TextE
AutoCAD SHX TextN
AutoCAD SHX TextN
AutoCAD SHX TextS
AutoCAD SHX TextY
AutoCAD SHX TextL
AutoCAD SHX TextV
AutoCAD SHX TextA
AutoCAD SHX TextN
AutoCAD SHX TextI
AutoCAD SHX TextA
AutoCAD SHX TextPE060405
AutoCAD SHX TextMATTHEW JON VERTUCCI
De
scrip
tio
n
RE
VIS
IO
NS
:
Da
te
SHEET : P3.0
Scale: As Noted
FIRST FLOOR
DOMESTIC WATER
FIRST FLOOR DOMESTIC WATER PIPING PLAN
Scale: 3/32" = 1'-0"
Checked By: MJV
Drawn By: JP
Designed By: JP
MA
TT
HE
W J. V
ER
TU
CC
I
PA
. L
IC
. N
O. P
E-0
60
40
5
Ve
rte
ch
E
ng
in
ee
rin
g A
sso
cia
te
s
24
4 D
an
ville
R
oa
d
Blo
om
sb
urg
, P
en
nsylva
nia
1
78
15
Ph
on
e: (5
70
) 4
37
-2
10
0
Fa
x: (5
70
) 4
37
-3
10
0
NE
W C
HE
VR
OL
ET
/ V
OL
VO
D
EA
LE
RS
HIP
F
OR
:
Gre
en
ca
stle
, P
en
nsylva
nia
An
trim
T
ow
nsh
ip
, F
ra
nklin
C
ou
nty
AL
EX
AN
DE
R F
AM
IL
Y D
EA
LE
RS
HIP
S
BA
M Jo
b #
: 2
00
0
Date: August 1, 2016
EN
GIN
EE
R
J
K
M
N PO
HOSE
REEL
L
UP
FIRE SEPARATION LEGEND
- 1 HOUR SEPARATION
- 2 HOUR SEPARATION
UP
37 12
36 13
34 15
11
09
08
3x5 DS
04
02
01
03
24 21
23 22
29
30
31
33 16
32
10
06
35 14
UP
AA
HC
BE
NC
H
HCHC
07
05
KEY
DROP-BOX
26 19
25 20
28 17
27 18
KEY
DROP-BOX
DW
UP
UP
WASH / DETAIL
BAY
WASH / DETAIL
BAY
WASH / DETAIL
BAY
WASH / DETAIL
BAY
QUICK LUBE
BAY
QUICK LUBE
BAY
QUICK LUBE
BAY
QUICK LUBE
BAY
SERVICE LANES
123
ELEV. MACH.
150
PARTS
STORAGE
152
SHOWROOM
139
ELEV.
LOBBY
148
BUS. DEV.
CENTER
142
SERVICE WRITE-UP
124
MEN
128
WOMEN
129
RETAIL
PARTS
130
HOSPITALITY
131
PARTS
COUNTER
154
SALES
137
SALES MGR.
144
CHILDREN
133CUST. LOUNGE
132
TECH TLT.
155
F&I
143
TECH LUNCH
158
VEST.
138
CORRIDOR
145
CORRIDOR
126
TECH
LOCKER
156
FILES
127
SERVICE MGR.
125
ELEV.
SALES
136
ASST.
SVC. MGR.
153
RECEIVING
151
SALES
147
SALES
146
SALES
135
TOOL ROOM
120
MECH. ROOM
119
SERVICE BAYS
121
CORRIDOR
140
TECH
SHOWER
157
STORAGE 141
STORAGE
123b
TECH. TLT. 112
SERVICE WRITE-UP
114
SERVICE MGR.
113
MEN 108
WOMEN
109
JAN.
110
CHILDREN
111
LIVING ROOM
101
SALES 106
CONSULT. 105
SALES
104a
F&I
103
SALES MGR.
102
VOLVO
SHOWROOM
100
SERVICE LANES
115
AUTOMATIC
CAR WASH
118
EQUIPMENT
COMMON
AREA
122
SALES
134
TLT.
149
STAIR
#1
STAIR
#2
HC
HC
HC
HC
HC
HC
HC
HC
HC
UP
NORTHNORTH
NEW CAR
DELIVERY
NEW CAR
DELIVERY
FOUNTAIN
KNOX
BOX
CO
VE
RE
D
WA
LK
WA
Y
MECH.
ROOM
116
ELEC.
ROOM
117
CHEVROLET
NEW TIRE DISPLAY
VOLVO
NEW TIRE DISPLAY
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
3x5 DS
HC HC
STOR.
105a
SALES
104
SALES 107
DW
DS
SUMP
PIT
E
FG
B
C
SALT
H1
H
WASH
DOWN
PUMP
1-1/2"
1/2" CW DN
(TYP. 3)
3/4"
1"
1" DN
(TYP. 3)
3/4" DN
(TYP. 3)
3/4"
1/2" HW DN
(TYP. 3)
3/4"
2"
1/2"
CW DN
3/4"
1"
1/2" CW &
HW DN
HB
1
3/4" CW UP
3/4"
3/4"
1/2" CW &
HW DN
1/2" CW &
HW DN
HB
1
WC
3
L
3
U
2
WC
1
WC
1
WC
4
U
2
S
3
S
2
WH
3
L
4
L
4
S
3
TYP. (3)
S
2
U
2
TYP. (3)
WC
4
TYP. (2)
WC
3
KS
2
DF
2
WH
1
S
1
EW
1
HB
2
HB
2
HB
1
1/2"
1-1/2" CW UP
TO 2nd FLOOR
WATER HEATER
1/2"1/2" CW DN
1/2" HW DN
3/4" CW UP
3/4" CW UP
MOUNT HOSE BIBB
32" ABOVE FINISHED
FLOOR
1/2" CW UP
3/4" CW UP
3/4" CW & HW UP 3/4" CW & HW UP
3/4" CW & HW UP FROM
WASHING MACHINE BOX
3/4" CW & HW UP 3/4" CW & HW UP
3/4" HW UP
3/4" CW UP
1-1/4" HW UP
WB
1
1-1/2" CW UP
1/2" HW UP
3/4" DN
1"
1/2"
1" DN
1/2" CW &
HW DN
2" C
W
1" CW DN (TYP. 5)
1-1/2"
1/2" CW & HW DN
(TYP. 3)
L
1
TYP. (3)
WC
2
TYP. (2)
WC
1
2"2"
L
1
TYP. (3)
U
2
TYP. (2)
3/4" CW DN (TYP. 3)
1-1/2"
U
1
1"
2" C
W
1"
3/4"
1"
1" HW
APPROXIMATE LOCATION OF DOMESTIC WATER &
FIRE SERVICES TO BUILDING. MAINTAIN SEPARATION
BETWEEN WATER & ELECTRICAL SERVICES IN
ACCORDANCE WITH LOCAL CODES.
2-1/2" U.G. DOMESTIC WATER
6" U.G. SPRINKLER
6" FIRE
SERVICE UP
1"
1/2" CW &a