Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
N
LOCATION MAPSCALE: N.T.S.
1 2 3 4 5
A
B
C
D
SHEET OF
1301 Gervais Street, Suite 1300Columbia, SC 29201Phone (803) 799-6502www.pondco.com
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
7 Clusters Court, Suite 201Columbia, SC 29210Phone (803) 731-0650www.bea-consulting.com
BELKA ENGINEERING ASSOCIATES, INC.
1/1
4/2
020
11:0
8:4
8 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
G-001
CONSTRUCTION DOCUMENTS
PROJ. NO.: H27-Z407 50003375-2CONSTRUCTION DOCUMENTS
15 JANUARY 2020
COLUMBIA, SOUTH CAROLINA
CO
VE
R S
HE
ET
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
AH
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
PROJECT LOCATIONGAMBRELL HALL
SHEET INDEXSHEET
NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
LS-101 LIFE SAFETY PLAN
ARCHITECTURAL
A-001 GENERAL NOTES AND ABBREVIATIONS
A-002 PARTITION TYPES & DETAILS
AD101 DEMOLITION PLANS
A-101 RENOVATION PLANS
A-301 SECTION/ELEVATION & DETAILS
A-601 DOOR SCHEDULE & DETAILS
A-631 FINISH SCHEDULE & FURNITURE PLAN
ELECTRICAL
E-001 ELECTRICAL DEMOLITION PLAN
E-002 ELECTRICAL RENOVATION PLAN
UNIVERSITY OF SOUTH CAROLINAGAMBRELL 153 AUDITORIUM
MA
RK
DE
SC
RIP
TIO
ND
AT
E
OPEN
TO
ABOVE
DOOR
TOLOWER
LEVELCORRIDOR
H012
DN
UP
DN
UP
UP
UP
DN UPDN
DN DN DN DN
DN
DN
207 SF
MEN244 SF
WOMEN312 SF
1403 SF
305 SF
187 SF
LOBBY2100 SF
MEN337 SF
WOMEN278 SF
396 SF
CUST.35 SF
394 SF
153 SF
156 SF
ELEC.68 SF
CUST.94 SF
ELEC./COMM.
67 SF
760 SF
530 SF
TRASH2 SF
750 SF
193 SF
561 SF
COMM.12 SF
COVEREDWALKWAY
3683 SF
54 SF 51 SF 52 SF
616 SF 714 SF
99 SF
2431 SF
53 SF
45 SF
1455 SF1458 SF
77 SF
263 SF
612 SF
410 SF
175 SF
397 SF
292 SF
393 SF
141 SF
137 SF413 SF
136 SF137 SF
137 SF136 SF136 SF208 SF
180 SF 146 SF
137 SF
134 SF
137 SF
357 SF596 SF 577 SF
133 SF
137 SF
137 SF
129 SF
137 SF353 SF
596 SF
294 SF
134 SF
137 SF
127 SF 115 SF
207 SF 135 SF 135 SF 136 SF 132 SF 136 SF 133 SF 136 SF
157 SF 157 SF130 SF
103A 103
ST05
157
158
159
153
153A
153C
H108
152151
H107
156
ST04
V103
V101
161162
H105
155
H104
ST03
150
101
ST01
165
166
102
173
148
H103
105
106
109
H106
107108
110113
115116118119
117 114
120
121
122
167
123
124 104
H101
126125
ST02
127128
131
130
129
149
132
133
137 140
H102
134 135 138 139 142 143 146 147
144 145
168
136
X101
EV01 EV02 EV03
103A 103
ST05
157
158159153
153A
153C
H108
152151
H107
156
ST04
V103
V101
161
162
H105
155
H104
ST03
150
101
ST01
165
166
102
173
148
H103
105
106
109
H106
107108
110113
115116118119
117 114
120
121
122
167
123124 104
H101
126
125
ST02 127
128
131130
129
149
132
133
137 140
H102
134 135 138 139 142 143 146 147
144 145
168
136
X101
EV01 EV02 EV03
GENERAL LIFE SAFETY SHEET NOTES:
1. DEVICES HAVE BEEN SHOWN; BUT THE CONTRACTOR SHALL ENSURE THE INSTALLATION OF ALL LIFE SAFETY DEVICES INDICATED ON THE ENGINEERING DRAWINGS.
2. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF ANY EXISTING FIRE RATED WALLS. ANY WORK DONE AROUND EXISTING FIRE RATED WALLS SHALL BE DONE WITH CARE SO AS NOT TO COMPROMISE THE RATING'S INTEGRITY. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.
3. CONTRACTORS SHALL FOLLOW EM-385-1-1 AND NFPA 241, ALONG WITH THE INSTALLATION’S FIRE REGULATIONS.
4. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL:
a. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED HORIZONTALLY
ALONG WITH WALL OR PARTITION. b. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8-INCH STROKE IN A CONTRASTING COLOR
INCORPORATING THE SUGGESTED WORDING, “FIRE AND/OR SMOKE BARRIER – PROTECT ALL OPENINGS,” OR OTHER WORDING
1-HR. RATED WALLS
LIFE SAFETY PLAN LEGEND
45'-0"TRAVEL DISTANCE
EXIT SIGN WITH DIRECTION ARROWS-SEE ELECT. DWGS.
EGRESS CLEAR WIDTHCAPACITY/NO. OF OCCUPANTS
2-HR. RATED WALLS
STARTING POINT FOR TRAVEL DISTANCE
36"100/100
48
' - 7"
CATCHMENT AREA FOR EXIT
84 SEATS
59'-0"
37'-8"
68"309/154
34"154/59
68"309/95
DEAD END
13' - 1"
CATCHMENT AREA FOR EXIT
56 SEATS
CATCHMENT AREA FOR EXIT
85 SEATS
CATCHMENT AREA FOR EXIT
57 SEATS
4' - 0"
2' - 11"
1/2 DIAGONAL DISTANCE = 30'-3"
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
9 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
LS-101
CONSTRUCTION DOCUMENTS
LIF
E S
AF
ET
Y P
LA
N
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
LS
W
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
CODE REVIEW SUMMARY
PER IBC 2015, THE FOLLOWING ASSUMPTIONS WERE MADE BASED UPON EXISTING DRAWINGS DATED 6/21/1975:- BUILDING IS APPROXIMATELY 139,000 SF, TYPE IB CONSTRUCTION, 5-STORIES PLUS LOWER LEVEL, AND NON-SPRINKLERED.- BUILDING IS CLASSIFIED AS SEPARATED MIXED-USE WITH BUSINESS OCCUPANCY AND ASSEMBLY GROUP A-3-FIRE RESISTIVE RATINGS: IBC, TABLE 601; SECTION 602.2STRUCTURAL FRAME 2 HR.EXT. BEARING WALLS 2 HR.INT. BEARING WALLS 2 HR.INT. NON-BEARING WALLS AND PARTITIONS 0 HR.FLOOR CONSTRUCTION 2 HR.ROOF CONSTRUCTION 1 HR.CORRIDORS 1 HR.
-ALLOWABLE HEIGHT:ASSEMBLY (A-3) (MOST RESTRICTIVE), 160 FT/ 11 STORIES (AS PER IBC 504.3 & 504.4)
-ALLOWABLE AREA: ASSEMBLY (A-3) (MOST RESTRICTIVE), BASED ON IBC TABLE 506.2 - UNLIMITED SQUARE FEETEXIT REQUIRMENTS (PER NFPA 101 LSC):-2 MEANS OF EGRESS REQUIRED (13.2.4.2)-MINIMUM AISLE ACCESSWAY WIDTH BETWEEN ROWS OF SEATS IS 12" (13.2.5.5.2).-DEAD END AISLE MAX DISTANCE IS 20'-0" (13.2.5.6.2).-MINIMUM AISLE WIDTH: 42" FOR CATCHMENT AREAS GREATER THAN 60 SEATS, 30" FOR CATCHMENT AREAS LESS THAN 60 SEATS (13.2.5.6.3). -AISLE STAIR TREAD DEPTH NOT LESS THAN 11" (13.2.5.3.5), EXISTING DEPTH 18".-AISLE STAIR RISER HEIGHT NOT LESS THAN 3-1/2" (13.2.5.6.6), EXISTING HEIGHT 4".-AISLE HANDRAILS NOT REQUIRED WHERE RISERS ARE LESS THAN 7" IN HEIGHT (13.2.5.6.9.7).-CONTRASTING NOSING REQUIRED (13.2.5.6.10.1).-MAXIMUM TRAVEL DISTANCE TO EXIT IS 200' (13.2.6.1).
SCALE: 3/32" = 1'-0"A1LIFE SAFETY PLAN
SCALE: = 1'-0"3/32"
0 8 16 248
NORTH
WORK AREA PER IEBC 2015, RENOVATION ISCLASSIFIED AS AN "ALTERATION-LEVEL1"
MA
RK
DE
SC
RIP
TIO
ND
AT
E
ARCHITECTURAL ABBREVIATIONS
CL
GENERAL NOTES:
SYMBOLS:
VIEW TITLES:
PLAN SYMBOLS:
MATERIALS IN SECTION - FILL PATTERNS:
A.F.A.F.F.ACC. DR.ADAAG
ACCESS.ADJ.ACOUST.A.B.ACTANOD.A.C.AL / ALUM.&LAPP.APPROX.ARCH.@AT / FPAVG.A.W.I.
B.H.M.I.
BM.BLKG.BD.BTM.BLDG.B.U.R.
CFCI
CH.CPT.CLG.CLG. HT.CTR.
C. TO C.C.T.CLR.C.O.CLOS.CO.COL.CONC.CORR.COTR
CMUCONF.CONST.CONT.CONTR.C.J.C.Y.
DET.DIA.DIM.DISP.DR.DN.D.S.DESC.DWG.
EA.ELEC.EL.E.W.C.E.R.D.E.P.ENGR.EQUIP.EQ.EXIST.EXP.E.J. (EXP. JT.)EXP. TO STRUCT.EXT.ETD
FAC.FDCFT.F.E.F.E.C.F.H.C.FIN.F.P.F.F.FLR.F.D.FLUOR.F.O.G.FTG.FDN.FV.
RAISED ACCESS FLOORRECEPTIONISTREFERENCEREINFORCEMENTREQUIREDREVISIONS / REVISEDROOF DRAINRIGHT HANDRIGHT HAND REVERSEROOMROUGH OPENINGRUBBER BASE
SEALED CONCRETESOLID CORE WOODSCHEDULESECTIONSEMI-GLOSS PAINTSERVICE SINKSHEET METALSIMILARSOUND TRANSMISSION CLASSSPECIFICATIONSPRAYED FIRE RESISTIVE MATERIALSQUARESTAINSTAINLESS STEELSTANDARDSTEELSTORAGESTRUCTURALSUSPENDED
TOILETTELEPHONETHICKTHRESHOLDTEMPERED GLASSTOP OFTOP OF BEAMTOP OF CONCRETETOP OF CURBTOP OF STEELTOP OF WALLTOUCH-UPTYPICAL
UNDERWRITERS LABORATORIESUNFINISHEDUNLESS NOTED OTHERWISE
VERTICALVESTIBULEVINYL COMPOSITION TILEVINYL COVE BASEVENT THRU ROOF
WIDTHWITHWATER CLOSETWALL CLEAN OUTWOODWINDOWWIRE MESH PARTITIONWITHOUTWATER RESISTANT GYPSUM BOARDWEATHERSTRIPPINGWINDOW ROUGH OPENING
YARD
SECTION NUMBER
DWG. NO. WHERE SECTION IS DRAWN
WALL SECTION MARK
SECTION NUMBER
DWG. NO. WHERE SECTION IS DRAWN
BUILDING SECTION MARK
ELEVATION NUMBER (TYP.)
DWG. NO. WHERE ELEVATION IS DRAWN
INTERIOR ELEVATION MARK
DWG. NO. WHERE DETAIL IS DRAWN
CALLOUT HEAD
DETAIL NUMBER (TYP.)
AREA COVERED BY DETAIL
DOOR TAG WINDOW & LOUVER TAG
ROOM TAG PARTITION TYPE
EARTH
CONCRETE / GROUT
SAND / E.I.F.S. / PLASTER / STUCCO
STEEL
MASONRY - CONCRETE BLOCK
MASONRY - BRICK
RIGID INSULATION
BATT INSULATION EXPOSED & FINISHED WOOD TRIM
GYPSUM / PLASTER
PLYWOOD
ACCESS FLOORINGABOVE FINISHED FLOORACCESS DOOR / PANELAMERICAN WITH DISABILITIES ACCESSIBILITY GUIDELINESACCESSORIESADJUST/ ADJUSTABLEACOUSTICALANCHOR BOLTACOUSTICAL CEILING TILEANODIZEDAIR CONDITIONINGALUMINUMANDANGLEAPPROVEDAPPROXIMATEARCHITECTURALATANTI TERRORISM / FORCE PROTECTIONAVERAGEARCHITECTURAL WOODWORK INSTITUTE
BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION, INC.BEAMBLOCKINGBOARDBOTTOMBUILDINGBUILT-UP ROOFING
CONTRACTOR FURNISHED CONTRACTOR INSTALLEDCHANNELCARPETCEILINGCEILING HEIGHTCENTERCENTER LINECENTER TO CENTERCERAMIC TILECLEARCLEANOUTCLOSETCOMPANYCOLUMNCONCRETECORRIDORCONTRACTING OFFICER'S TECHNICAL REPRESENTATIVECONCRETE MASONRY UNITCONFERENCECONSTRUCTIONCONTINUOUSCONTRACTORCONTROL JOINTCUBIC YARD
DETAILDIAMETERDIMENSIONDISPENSERDOORDOWNDOWNSPOUTDESCRIPTIONDRAWING
EACHELECTRICAL OR ELECTRICELEVATIONELECTRIC WATER COOLEREMERGENCY ROOF DRAINEPOXY PAINTENGINEEREQUIPMENTEQUALEXISTINGEXPANSION / EXPOSEDEXPANSION JOINTEXPOSED TO STRUCTUREEXTERIORESTIMATED TRAVEL DISTANCE
FACTORYFIRE DEPARTMENT CONNECTIONFEETFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE HOSE CABINETFINISHFLAT PAINTFINISHED FLOORFLOORFLOOR DRAINFLUORESCENTFACE OF GIRTFOOTINGFOUNDATIONFIELD VERIFY
RAFRECEP.REF.REINF.REQ'D.REV.R.D.RHRHRRM.R.O.RB
SCSCWSCHED.SECT.S.G.P.SSKSHT. MET.SIM.STCSPEC(S)SFRM
SQ.ST.S.S.STD.STL.STOR.STRUCT.SUSP.
TOIL. / TLTTEL.THK.T'HOLDTGT/TOBTOCT/CTOST/WTUTYP.
U.L.UNFINU.N.O.
VERT.VEST.VCTVCBV.T.R.
W.W/W.C.WCOWD.WDW.W.M.P.W/OW.R.G.B.
W.S.W.R.O.
YD.
GRAVEL
KEYNOTE TAG
CEILING TAG(HEIGHT)
CEILING TAG(TYPE & HEIGHT)
CEILING HGT.
CEILING TYPESUBSCRIPT TYPE (AS REQ)
PARTITION TYPE
EQUIPMENT TAG
GA.GALV.G.B.F.GFCI
GFGI
G.L.G.P.GL.GOVT.GYP.GYP. BD. (GWB)
HKSHR.HDW.HGT.H.H.P.H.M.HORIZ.HBH.V.A.C.
IN.I.D.INSUL.INT.
JAN.J.C.JT.JST.
K.P.
LAM.LDG.LAV.L.H.LHRLT.LTG.LONG.LVR.L.P.
MAS.M.O.MGR.MANUF.MATL.MAX.MECH.MTL.M.W.P.MIN.MISC.
N.I.C.NO. (#)NTSNFPA
O.C.OFCI
OFGI
O.H.OPNG.O.W.OPP.O.D.OSHA
OVHD
PDUPTPR.PNL.PART.PLAS.PLPLYWD.LBS. OR #PSFPSIP.M.J.F.PRE-FAB.
Q.T.
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED THEREFROM.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW WORK.
6. ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF WORK AGREEMENT.
7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.
8. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
10. UNLESS NOTED OTHERWISE, ALL GYPSUM BOARD SURFACES ARE TO RECEIVE ONE PRIMER COAT AND TWO COATS OF PAINT.
11. DIMENSIONS NOTED AS 'HOLD' SHALL NOT VARY BY MORE THAN 1/8" FROM SIDE TO SIDE OR FROM FRONT TO BACK, FINISHED SURFACE TO FINISHED SURFACE.
12. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS SHALL BE APPLIED.
13. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING SHALL BE CONSTRUCTED AS DETAILED HEREIN.
14. DIMENSIONS SHOWN ARE TO FACE OF STUD OR CMU (U.N.O.).15. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER
PRODUCT MANUFACTURER'S STANDARDS. 16. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
17. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES.
18. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.
19. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON INDIVIDUAL SHEETS SHALL BE APPLIED TO RELATED DRAWINGS AND DETAILS.
20. A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL IS TO BE FINISHED OR FIRE-RATED AS INDICATED.
21. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR OPENINGS, THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE THE LOCATION OF ADJACENT WALLS AND FRAMES.
22. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
23. THE CONTRACTOR SHALL COORDINATE ALL ELECTRICAL FLOOR AND WALL SLEEVES INCLUDING CONDUITS WITH ALL ELECTRICAL AND ARCHITECTURAL DRAWINGS.
24. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.
25. INTERIOR PARTITION MOVEMENT CONTROL:A. VERTICAL CONTROL JOINTS FOR ANY WALL LENGTH ARE TO OCCUR
AT NOT MORE THAN 30'-0" O.C. IN THE HORIZONTAL DIRECTION, UNLESS NOTED OTHERWISE.
B. PROVISIONS SHALL BE MADE IN THE DESIGN, FABRICATION, AND INSTALLATION OF INTERIOR PARTIONS FOR TYPICAL FLOOR DEFLECTIONS OF THE STRUCTURE UNDER SUPERIMPOSED LOADS AS FOLLOWS:
a. TYPICAL ROOF/FLOOR MEMBERS: SPAN/360 BUT NOT LESS THAN 1/2”.
26. THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
27. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE OWNER'S REPRESENTATIVE PRIOR TO START OF SUCH WORK. THE WORK IS INTENDED TO BE COMPLETED OVER THE SUMMER . CONTRACTOR IS RESPONSIBLE FOR SECURING THE SPACE AND DUST CONTROL.
GAGE OR GAUGEGALVANIZEDGYPSUM BOARD FURRINGGOVERNMENT FURNISHED CONTRACTOR INSTALLEDGOVERNMENT FURNISHED GOVERNMENT INSTALLEDGIRT LINEGLOSSY PAINTGLASSGOVERNMENTGYPSUMGYPSUM BOARD
HOOKSHANDRAILHARDWAREHEIGHTHIGHHIGH POINTHOLLOW METALHORIZONTALHOSE BIBBHEATING VENTILATION & AIR CONDITIONING
INCHINSIDE DIAMETERINSULATIONINTERIOR
JANITORJANITOR'S CLOSETJOINTJOIST
KICK PLATE
LAMINATELANDINGLAVATORYLEFT HANDLEFT HAND REVERSELIGHTLIGHTINGLONGITUDINALLOUVERLOW POINT
MASONRYMASONRY OPENINGMANAGERMANUFACTURERMATERIALMAXIMUMMECHANICALMETALMETAL WALL PANELMINIMUMMISCELLANEOUS
NOT IN CONTRACTNUMBERNOT TO SCALENATIONAL FIRE PROTECTION ASSOCIATION
ON CENTEROWNER FURNISHED CONTRACTOR INSTALLEDOWNER FURNISHED GOVERNMENT INSTALLEDOPPOSITE HANDOPENINGOPEN WEBOPPOSITEOUTSIDE DIAMETEROCCUPATIONAL SAFETY AND HEALTH ACTOVERHEAD
POWER DISTRIBUTION UNITPAINTPAIRPANELPARTITIONPLASTER OR PLASTICPLATEPLYWOODPOUNDSPOUNDS / SQUARE FOOTPOUNDS / SQUARE INCHPRE-MOLDED JOINT FILLERPREFABRICATED
QUARRY TILE
DETAIL IDENTIFIER (MODULE LETTER AND NUMBER)
NORTH ARROWS
FLOOR PLANS, ELEVATIONS OR DETAIL VIEWS TITLE
A-101
1SIM
A-101
ROOM NAME101
A101 12'-0" A.F.F. 1t 12'-0" A.F.F.A1-X 1i
N
A1ELEVATIONS, DETAILS & CALLOUTSSCALE: 1/8" = 1'-0"
A101
1
EXTERIOR ELEVATION MARK
ELEVATION NUMBER (TYP.)
DWG. NO. WHERE ELEVATION IS DRAWN
REVISION TAG
1
1
1
1
1
N
NCS AEC
DEMOLITION KEYNOTE TAG
(NAVFAC)
TRUE NORTH
TRUE NORTH
DETAIL NUMBER
DWG. NO. WHERE SECTION IS DRAWN
DETAIL SECTION MARK
A1
A-101
SIMA1
A-101
SIMA1
A-101
SIMA1
A-101
SIM
# #
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
5 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
A-001
CONSTRUCTION DOCUMENTS
GE
NE
RA
L N
OT
ES
AN
D A
BB
RE
VIA
TIO
NS
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
LS
W
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
MA
RK
DE
SC
RIP
TIO
ND
AT
E
INTERIOR PARTITION GENERAL NOTES
1. PARTITION TYPES DESCRIBE GENERAL REQUIREMENTS FOR PARTITIONS. REFER TO THE MANUFACTURER'S SPECIFICATIONS AND REQUIREMENTS OF APPLICABLE TESTING AGENCIES FOR SPECIFICS OF PARTITION CONSTRUCTION.
2. REFER TO "PARTITION TYPE NOMENCLATURE" FOR SYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS AND MODIFIERS TO BASIC PARTITION TYPES.
3. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.
4. TYPICAL FLOOR PLAN DIMENSIONS OF PARTITIONS ARE TO FACE OF STUD OR CMU UNLESS NOTED OTHERWISE.
5. WHERE A CLEAR OPENING DIMENSION IS INDICATED, THE DIMENSION IS MEASURED FACE-TO-FACE BETWEEN FINISHED SURFACES.
6. REFER TO SPECIFICATIONS FOR MINIMUM STUD DESIGN CRITERIA, MAXIMUM SPACING AND ALLOWABLE LIMITING HEIGHTS DEFLECTION CRITERIA FOR GYPSUM BOARD.
7. METAL STUD GAUGE (IF NOTED) AND UL TEST NUMBERS WILL VARY DEPENDING ON THE MANUFACTURER OF COMPONENTS ACTUALLY USED.
8. REFER TO FLOOR PLANS FOR FIRE PROTECTION RATINGS.
9. ALL RATED PARTITIONS SHALL BE LABELED ABOVE CEILING WITH LABELS PER AHJ AS REQUIRED. IBC CHAPTER 7 AT MINIMUM.
10. PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THE PARTITIONS TO OTHER PORTIONS OF THE WORK TO BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED DETAILS AND IN COMPLIANCE WITH APPLICABLE TESTING AGENCY REQUIREMENTS.
11. INSTALLATION OF GYPSUM BOARD, BACKER BOARD AND BASE BOARD TO CONFORM TO REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS.
12. PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREAS THAT ARE NOTED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMIC OR PORCELAIN TILE FINISH.
13. INSTALL BLOCKING OR BACKER MATERIAL FOR ATTACHMENT / MOUNTING OF WALL HUNG ITEMS OR EQUIPMENT DESCRIBED IN THE DOCUMENTS. ALL BLOCKING TO BE FIRE RETARDANT TREATED.
14. PARTITIONS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE ARE TO HAVE THE GYPSUM BOARD CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE TO THE SHAPE OF THE DECK ABOVE. GYPSUM BOARD SHALL BE CONTINUOUSLY SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT.
15. PROVIDE METAL STRAPPING @ 24" VERT. TO HOLD BATT INSULATION FOR AREAS WITHOUT GYPSUM WALLBOARD.
16. GYPSUM BOARD IS TO BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELECTRICAL OUTLET BOXES AND THE GYPSUM BOARD DOES NOT EXCEED 1/8".
17. THE BOTTOM OF THE GYPSUM BOARD AT INTERIOR PARTITIONS IS TO BE 1/4" MINIMUM AND 1/2" MAXIMUM ABOVE THE FLOOR STRUCTURE AND IS TO BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT.
18. REFER TO INTERIOR FINISH SCHEDULE FOR WALL FINISHES.
19. REFER TO PARTITION TYPE MODIFIERS FOR STC RATED PARTITIONS
CAULKLINE OF FLOOR STRUCTURE
METAL RUNNER
GYPSUM BOARD
REFER TO FURRING STUD SCHEDULE BELOW FOR PARTITION WIDTH
WIDTH
PL
AN
BRACE EACH STUD AT 4'-0" OC VERTICALLY
METAL RUNNER
LINE OF CEILING
HE
AD
BA
SE
PARTITION TYPE F
FURRING STUD SCHEDULE
MARKSTUDWIDTH
GWBLAYERS
PARTITIONWIDTH
FIRERATING UL LISTING
F 3-5/8" (1) 5/8" 4 1/4" 0 HR N/A
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
6 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
A-002
CONSTRUCTION DOCUMENTS
PA
RT
ITIO
N T
YP
ES
& D
ET
AIL
S
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
AH
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
MA
RK
DE
SC
RIP
TIO
ND
AT
E
UP
DN DN
DN
207 SF
MEN244 SF
WOMEN312 SF
1403 SF
99 SF
2431 SF
53 SF
45 SF
77 SF
263 SF
ST05
157
158
159
153
153A
153C
H108
152151
V103
ST05
157
158159153
153A
153C
H108
156
V103
207 SF
MEN244 SF
WOMEN312 SF
1403 SF
99 SF
53 SF
45 SF
77 SF
263 SF
ST05
ST05
157
158159
153A
153C
H108
156
V103
DEMOLITION PLAN LEGEND
EXISTING WALL PARTITIONS TO REMAIN
ITEMS TO BE REMOVED
EXISTING DOOR, FRAME AND ACCESSORIES TO REMAINUNLESS NOTED OTHERWISE
N.I.C.
1. SEE SHEET A-001 FOR GENERAL NOTES. 2. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.3. WHILE WORK UNDER THIS CONTRACT IS IN PROCESS,
PROTECT EXISTING BUILDING, GROUNDS AND CONTENTS INCLUDING ADJACENT AREAS FROM DAMAGE OR HARM.
4. ALL DEMOLITION MATERIAL, EQUIPMENT AND DEBRIS SHALL BE REMOVED FROM THE SITE TO AN AREA DESIGNATED BY THE OWNER'S REPRESENTATIVE.
5. THE CONTRACTOR SHALL REVIEW INSTALLATION DRAWINGS FOR NEW MATERIALS AND BE FAMILIAR WITH LIMITS OF DEMOLITION. THE CONTRACTOR SHALL KNOW AND UNDERSTAND NEW MATERIAL INSTALLATION IN AREAS WHERE EXISTING MATERIALS ARE REMOVED.
6. PROVIDE TEMPORARY SHELTER OR PORTALS AT ENTRANCES AND EXIT DOORS AS MAY BE REQUIRED FOR PROTECTION FROM FALLING DEBRIS OR OPEN TRENCHES. TEMPORARY PORTALS AND WALKWAYS ARE TO MEET ALL CODE REQUIREMENTS FOR WIDTH AND WALKING SURFACE CONTINUITY.
7. REPORT DATED 12/17/2019 PROVIDED BY THE UNIVERSITY OF SOUTH CAROLINA STATES THAT ROOM WAS TESTED AND FOUND TO BE FREE OF ASBESTOS CONTAINING MATERIALS.
8. FIRESTOP ALL PENETRATIONS OF SMOKE/FIRE PARTITIONS. FIRESTOPPING SHALL BE OF UL LISTED ASSEMBLY. THIS INCLUDES EXISTING PENETRATIONS THROUGH BARRIERS AND OPENINGS DUT TO SCOPE OF DEMO WORK ON THIS PROJECT. REFER TO LIFE SAFETY PLAN SHEET G-101 FOR RATED WALLS.
9. MAINTAIN AND PROTECT ALL SURFACES AND ITEMS TO REMAIN. SURFACES DAMAGED SHALL BE REPAIRED OR REPLACED TO LIKE NEW CONDITIONS.
DEMOLITION PLAN SHEET NOTES:KEYNOTES:
(KEYNOTE NUMBERS ARE UNIFORM ACROSS ALL SHEETS AND SOME MAY NOT BE REQUIRED ON THIS SHEET)
1
2
3
4 4
5
DOOR TO LOWER LEVEL CORRIDOR H012
6
7
9
8
11
153D
153B
16
10
11
N.I.C. (TYP)
12
13
14
15
N.I.C. (TYP)
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
8 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
AD101
CONSTRUCTION DOCUMENTS
DE
MO
LIT
ION
PLA
NS
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
AH
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
SCALE: 1/8" = 1'-0"A1DEMOLITION PLAN
SCALE: 1/8" = 1'-0"A3REFLECTED CEILING PLAN - DEMOLITION
NORTH NORTH
SCALE: = 1'-0"
0 8 168
1/8"
KEYNOTE LEGEND DEMOLITION PLANS
KEY# KEYNOTE DESCRIPTION
1 REMOVE AND DISPOSE OF ALL EXISTING SEATING AND STUDENT DESKSLOCATED IN AUDITORIUM 153 OF GAMBRELL HALL. PATCH THE EXISTINGCONCRETE TIERS (AS REQUIRED).
2 REMOVE ALL EXISTING STAIR NOSINGS AND CARPETING TO BARESUBSTRATE (TYP. THROUGHOUT ROOM), INCLUDING FACES OF RISERSAND STAGE. REMOVE ALL EXISTING WALL BASE IN ITS ENTIRETY (TYP.THROUGHOUT ROOM).
3 REMOVE EXISTING AV CABINET AND COMPONENTS. EXISTING AVCONDUITS AND POWER SHALL BE REUSED AS IS. ENCLOSE ABANDONEDAV CABINET AREA WITH NEW 3 5/8" METAL STUDS AT 16" 0.C. AND 1LAYER OF 5/8" GYPSUM WALLBOARD.
4 REFURBISH EXISTING DOORS. SEE SHEET A-601.
5 UNIVERSITY OF SOUTH CAROLINA TO REMOVE EXISTING LECTERN ANDCOORDINATE THE LOCATION OF THE NEW LECTERN WITH UNIVERSITYOF SOUTH CAROLINA.
6 REMOVE AND REPLACE EXISTING DOOR HARDWARE.
7 EXISTING PROJECTION SCREEN TO BE ABANDONED IN PLACE. POWERSHALL BE DISCONNECTED AND RECONNECTED (D/R). COORDINATE WITHELECTRICAL DRAWINGS.
8 REMOVE AND REPLACE EXISTING AISLE LIGHTING. RETAIN ELECTRICALPOWER FOR NEW AISLE LIGHTS. COORDINATE WITH UNIVERSITY OFSOUTH CAROLINA DURING CONSTRUCTION.
9 REMOVE AND REPLACE EXISTING OUTLET COVERS.
10 REMOVE EXISTING "COLLEGE OF ARTS AND SCIENCES" LOGO FROMWALL. PATCH AND PAINT WALL.
11 REMOVE AND REPLACE EXISTING EXIT LIGHTS.
12 REMOVE AND REPLACE EXISTING GRILLE CLOTH FABRIC OVER EXISTINGSPEAKERS WITH NEW ALTERNATE #1
13 EXISTING PENDANT FIXTURES SHALL BE RELAMPED BY USC FACILITIESDURING CONSTRUCTION, AFTER THE EXISTING SEATS HAVE BEENREMOVED. CONTRACTOR SHALL COORDINATE WITH USC DURINGCONSTRUCTION.
14 EXISTING DOWNLIGHTS SHALL BE CHANGED OUT TO DIMMABLE LEDWITH SEVERAL CIRUCUITED WITH GENERATOR-BACKED CIRCUIT FOREMERGENCY EGRESS PURPOSES. SEE ELECTRICAL.
15 EXISTING ACOUSTICAL PANELS OVER STAGE SHALL BE REMOVED ANDREPLACED WITH NEW.
16 REMOVE EXISTING WOOD BLOCK MOUNT FOR FORMER PENCILSHARPENER
MA
RK
DE
SC
RIP
TIO
ND
AT
E
UP
DN DN
DN
207 SF
MEN
244 SF
WOMEN
312 SF
1403 SF
99 SF
2431 SF
53 SF
45 SF
77 SF
263 SF
ST05
157
158
159
153
153A
153C
H108
152151
V103
ST05
157
158159153
153A
153C
H108
156
V103
207 SF
MEN
244 SF
WOMEN
312 SF
1403 SF
99 SF
53 SF
45 SF
77 SF
263 SF
ST05
ST05
157
158159
153A
153C
H108
V103
1. PARTITIONS SHALL BE TYPE "F" (NO SUBSCRIPT) UNLESS OTHERWISE INDICATED.
2. SEE SHEET A-001 FOR GENERAL NOTES.3. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.4. WHILE WORK UNDER THIS CONTRACT IS IN PROCESS,
PROTECT EXISTING BUILDING, GROUNDS AND CONTENTS INCLUDING ADJACENT AREAS FROM DAMAGE OR HARM.
5. ALL WASTE MATERIAL, EQUIPMENT AND DEBRIS SHALL BE REMOVED FROM THE SITE TO AN AREA DESIGNATED BY THE OWNER'S REPRESENTATIVE.
6. THE CONTRACTOR SHALL REVIEW DEMOLITION DRAWINGS FOR REMOVED MATERIALS AND BE FAMILIAR WITH LIMITS OF DEMOLITION. THE CONTRACTOR SHALL KNOW AND UNDERSTAND NEW MATERIAL INSTALLATION IN AREAS WHERE EXISTING MATERIALS ARE REMOVED.
7. PROVIDE TEMPORARY SHELTER OR PORTALS AT ENTRANCES AND EXIT DOORS AS MAY BE REQUIRED FOR PROTECTION FROM FALLING DEBRIS OR OPEN TRENCHES. TEMPORARY PORTALS AND WALKWAYS ARE TO MEET ALL CODE REQUIREMENTS FOR WIDTH AND WALKING SURFACE CONTINUITY.
8. REPORT DATED 12/17/2019 PROVIDED BY UNIVERSITY OF SOUTH CAROLINA STATES THAT ROOM WAS TESTED AND FOUND TO BE FREE OF ASBESTOS CONTAINING MATERIALS.
9. DIMENSIONS OF EXTERIOR WALLS ARE TO FACE OF WALL FINISH U.N.O.
10. DOORS INDICATED WITH ####. SEE SHEET A-601 FOR DOOR SCHEDULE & TYPES.
11. KEYNOTES INDICATED WITH .12. NEW FINISHES SHALL BE SELECTED BY USC.13. COORDINATE WITH BELKA FOR ELECTRICAL.14. COORDINATE WITH USC FOR AV.
FLOOR PLAN NOTES:
F
1
2
3
DOOR TO LOWER LEVEL CORRIDOR H012
4
153D
153B
5
6
A2
A-30113 13
14
15
B1
A-301
TYP.
N.I.C. (TYP)
WALL LEGENDEXISTING WALLPARTITION TO REMAIN
NEW WALL PARTITION
KEYNOTES:
(KEYNOTE NUMBERS ARE UNIFORM ACROSS ALL SHEETS AND SOME MAY NOT BE REQUIRED ON THIS SHEET)
7
8
9
1011
11
11
12
N.I.C.
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
6/2
020
12:4
9:3
3 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
A-101
CONSTRUCTION DOCUMENTS
RE
NO
VA
TIO
N P
LA
NS
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
AH
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
SCALE: 1/8" = 1'-0"A1FLOOR PLAN - RENOVATION
SCALE: = 1'-0"
0 8 168
1/8"
NORTHSCALE: 1/8" = 1'-0"A3REFLECTED CEILING PLAN - RENOVATION
NORTH
KEYNOTE LEGEND RENOVATION PLANS
KEY# KEYNOTE DESCRIPTION
1 PROVIDE NEW AUDITORIUM SEATING (282 SEATS) WITH 151 SQ. IN. TABLETARM. BASIS OF DESIGN IS IRWIN SEATING COMPANY OR EQUAL (SEESPECIFICATIONS FOR APPROVED EQUALS). AUDITORIUM SEATING WILL NOTBE POWERED WITH THE EXCEPTION OF THE AISLE LIGHT.
2 NEW PROJECTION SCREEN SHALL BE WALL MOUNTED UNDERNEATHEXISTING SCREEN. POWER NEEDS TO BE DISCONNECTED ANDRECONNECTED (D/R). LOW VOLTAGE SCREEN CONTROL WIRING WILL NEEDTO BE PROVIDED FROM SCREEN INTERFACE TO AV RACK. GC TOCOORDINATE DELIVERY OF OWNER PURCHASED SCREEN. GC TO INSTALLAND CONNECT SCREEN AS REQUIRED. PROVIDE BLOCKING ASRECOMMENDED BY MANUFACTURER.
3 NEW AISLE LIGHTING SHALL BE PROVIDED WITH NEW SEATS, EVERY OTHERROW. COORDINATE POWER LOCATIONS WITH ELECTRICAL DRAWINGS.
4 PROVIDE NEW STAIR NOSINGS ACROSS FULL WIDTH OF RISERS AT MAINAISLES AND STAGE. PROVIDE NEW CARPETING (TYP. THROUGHOUT THEROOM), INCLUDING THE FACES OF RISERS AND STAGE. NEW CARPETINGSHALL BE INSTALLED PRIOR TO NEW SEAT INSTALLATION. PROVIDE NEWWALL BASE IN ITS ENTIRETY (TYP. THROUGHOUT ROOM). SEE FINISHSCHEDULE ON SHEET A-631 FOR STAIR NOSING MATERIAL.
5 PAINT ALL EXISTING WALLS LOCATED IN ROOM 153 OF GAMBRELL HALL.SEE FINISH SCHEDULE ON SHEET A-631.
6 NEW LECTERN PROVIDED AND INSTALLED BY UNIVERSITY OF SOUTHCAROLINA. COORDINATE LOCATION WITH UNIVERSITY OF SOUTHCAROLINA.
7 NEW GRILLE CLOTH FABRIC OVER EXISTING SPEAKER. SEE FINISHSCHEDULE ON SHEET A-631 - ALTERNATE #1.
8 NEW LED DIMMABLE DOWNLIGHTS (TYP.). SEE ELECTRICAL.
9 NEW ACOUSTICAL PANELS ABOVE STAGE. SEE FINISH SCHEDULE ON SHEETA-631.
10 EXISTING CEILING - (FLEXIBLE WOOD COVERING OVER PLASTER ON METALLATH) TYP.
11 EXISTING SUPPLY AIR DIFFUSER (TYP.)
12 EXISTING AREA OF RETURN AIR SLOTS BETWEEN WOODEN STRIPS.
13 REFURBISH EXISTING DOORS - PAINT INTERIOR, THOROUGHLY CLEANEXTERIOR FACE, NEW BLACK KICKPLATE AT EXTERIOR AND NEW CLOSERS.SEE SHEET A-601
14 PROVIDE NEW PANIC DOOR HARDWARE
15 ENCLOSE EXISTING AV CABINET AREA WITH NEW WALL, TYPE F. SEE A-002.
MA
RK
DE
SC
RIP
TIO
ND
AT
E
NO WORK THIS AREA
MITER WALL BASE, TYP.
EXISTING LIGHTENCLOSURE FORUP & DOWN LIGHTS, TYP.
NEW WALL INFILL SEE, SHEET A-002 FOR PARTITION TYPES &DETAILS
NEW WALL MOUNTEDPROJECTION SCREEN.PROVIDE BLOCKING PER MANUFACTUER RECOMMENDATION.
EXISTING CEILING (FLEXIBLE WOOD COVERING OVER PLASTER ON METAL LATH) TYP.
EXISTING STRUCTURE, TYP.
EXISTING PROJECTION SCREEN ABANDONED INPLACE
*NOTE: SEATING, OMMITED FOR CLARITY
A-301
A1
NEW GRILLE CLOTH FABRIC OVER EXISTING SPEAKERS. SEE FINISH SCHEDULE ON SHEET A-631 - ALTERNATE #1.
PROJECTION
ROOM253
AUDITORIUM
153
(FIE
LD
VE
RIF
Y)
5' -
11"
CLEAN TOP SURFACEOF CURVE - ENTIRE LENGTH
NEW ACOUSTICAL PANEL ATTACHED TO EXISTING WALL. SEE SHEET A-631AND SPECIFICATIONS
EXISTING CEILING (FLEXIBLE WOODCOVERING OVERPLASTER ON METALLATH) TYP.
FIE
LD
VE
RIF
Y
2' -
2"
3'-0" (FIELD VERIFY)
FV
.
4"
FV
.
4"
1'-6" (FIELD VERIFY)
NEW STAIR NOSINGS, SEE SHEET A-631 AND SPECIFICATIONS
NEW CARPET, SEE SHEET A-631 AND SPECIFICATIONS
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
7 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
A-301
CONSTRUCTION DOCUMENTS
SE
CT
ION
/ELE
VA
TIO
N &
DE
TA
ILS
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
AH
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
SCALE: 1/4" = 1'-0"A2SECTION/ELEVATION
SCALE: 1/2" = 1'-0"A1CEILING DETAIL
SCALE: 3" = 1'-0"B1STAIR NOSING DETAIL
MA
RK
DE
SC
RIP
TIO
ND
AT
E
A B
SEE DOOR SCHED. SEE DOOR SCHEDULE
SE
E D
OO
R S
CH
ED
ULE
SE
E D
OO
R S
CH
ED
ULE
GENERAL NOTES:1. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS WITHIN THE SCOPE OF WORK.2. REFER TO SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE SETS.
DOOR SCHEDULE
DO
OR
NU
MB
ER
SIN
GLE
(S
) O
R P
AIR
(P
R)
PANEL FRAME
FIR
E R
AT
ING
HA
RD
WA
RE
SE
T
COMMENTS
SIZE
TY
PE
MA
TE
RIA
L
GLA
ZIN
G
TY
PE
FR
AM
E M
AT
ER
IAL
HE
AD
JA
MB
SIL
L
WID
TH
HE
IGH
T
TH
ICK
NE
SS
153 6' - 0" 7' - 0" 1 3/4" B WOOD NA HM EXISTING --- 01
153B 3' - 0" 7' - 0" 1 3/4" A WOOD NA HM --- 02
153D 6' - 0" 7' - 0" 1 3/4" B WOOD NA HM --- 01
S
P
P
PROVIDE NEW BLACK KICK PLATES AND NEW FLOOR CLOSERS.
PROVIDE NEW BLACK KICK PLATES AND NEW FLOOR CLOSERS.
PROVIDE NEW PANIC DOOR HARDWARE.EXISTING
EXISTING
EXISTING EXISTING
EXISTINGEXISTING
EXISTING EXISTING
EXISTING
EXISTING
EXISTING
3. EXISTING DOORS & DOOR FRAMES WITHIN THE SCOPE OF WORK SHALL RECEIVE 2 COATS OF PAINT (TO MATCH WALLS).SEE FINISH SCHEDULE ON SHEET A-631.CARPET IS TO BE CUT AROUND THE FLOOR CLOSERS SO THAT THEY CAN BE ACCESSED AND SERVICED.4.
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
7 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
A-601
CONSTRUCTION DOCUMENTS
DO
OR
SC
HE
DU
LE
& D
ET
AIL
S
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
LS
W
AH
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
SCALE: 3/8" = 1'-0"C2DOOR PANEL TYPES
MA
RK
DE
SC
RIP
TIO
ND
AT
E
UP
DN DN
DN
207 SF
MEN244 SF
WOMEN312 SF
1403 SF
99 SF
2431 SF
53 SF
45 SF
77 SF
263 SF
ST05
157
158
159
153
153A
153C
H108
152151
V103
ST05
157
158159153
153A
153C
H108
156
V103
DOOR
TOLOWER
LEVELCORRIDOR
H012
UP
DN DN
DN
207 SF
MEN244 SF
WOMEN312 SF
1403 SF
99 SF
2431 SF
53 SF
45 SF
77 SF
263 SF
ST05
157
158
159
153
153A
153C
H108
152151
V103
ST05
157
158159153
153A
153C
H108
156
V103
AUDITORIUM153
STOR.153A STOR.
153C
LEGEND
CPT-1
NIC
STAIR NOSING
DOOR TO LOWER LEVEL CORRIDOR H012
N.I.C.DL-1 DL-1
CPT CARPETP PAINTTP TRIM PAINTRB RUBBER BASE
MATERIALS & FINISHES ABBREVIATIONS LIST
R1.
REMARKS
EXISTING PAINTED WOOD DOORS AND HMF TO BE PAINTED TP-1
(BASIS OF DESIGN) SEE SPECIFICATIONS FOR APPROVED , EQUALS AND SUBSTITUTION REQUESTS
WALLS
P-1 PAINT: SHERWIN WILLIAMS, CREAMY SW7012, SEMIGLOSSTP-1 TRIM PAINT: SHERWIN WILLIAMS, CREAMY SW7012, SEMIGLOSS
WALL BASE
RB-1 RUBBER WALL BASE: JOHNSONITE, 4" COVE BASE, 40 BLACK B
FLOOR
CPT-1 CARPET: BENTLEY MILLS, MISFIT #8FW24-801787, COLOR: BENEVOLENT, BROADLOOM INSTALLATION
MISC.
STAIR NOSING, TREDSAFE #AA346 ALUMINUM SAFETY TREAD W/ GLOW STRIPE, COLOR: CHARCOAL GREY 107
DL-1 REPLACE DAMAGED BLACK LAMINATE ON DOORS.
NOTE: CARPET IS TO BE CUT AROUND THE NEW FLOOR CLOSERS SO THAT THEY CAN BE ACCESSED AND SERVICED.
FINISH LEGEND
AUDITORIUM153
STOR.153A STOR.
153C
N.I.C. (TYP)
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
1301 G
erv
ais
Str
eet,
Suite 1
300
Colu
mbia
, S
C 2
9201
Phone (
803)
799-6
502
ww
w.p
ondco.c
om
SIZ
E:
AN
SI D
FIL
E N
AM
E:
SU
BM
ITT
ED
BY
:
CH
EC
KE
D B
Y:
DR
AW
N B
Y:
DE
SIG
NE
D B
Y:
ISS
UE
DA
TE
:
SO
LIC
ITA
TIO
N N
O.:
CO
NT
RA
CT
NO
.:
FIL
E N
UM
BE
R:
Copyright © 2019 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.
STAMP/SEAL
1/1
4/2
020
11:0
8:4
8 P
MC
:\U
se
rs\w
hite
l\D
ocum
en
ts\U
SC
Gam
bre
ll A
ud
itoriu
m_
Arc
h-I
_v1
9_
wh
itel2
6X
5B
.rvt
A-631
CONSTRUCTION DOCUMENTS
FIN
ISH
SC
HE
DU
LE
& F
UR
NIT
UR
E P
LA
N
GA
MB
RE
LL 1
53 A
UD
ITO
RIU
MU
NIV
ER
SIT
Y O
F S
OU
TH
CA
RO
LIN
AC
OLU
MB
IA,
SO
UT
H C
AR
OLIN
A
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A
GA
MB
RE
LL H
ALL, 817 H
EN
DE
RS
ON
ST
RE
ET
CO
LU
MB
IA, S
OU
TH
CA
RO
LIN
A 2
9208
JO
B N
O.
1200321
ED
M
ED
M
LM
15 J
AN
UA
RY
2020
PR
OJ. N
O.: H
27-Z
407
50003375-2
PR
OJ.
NO
.: H
27-Z
407 5
0003375-2
SCALE: 1/8" = 1'-0"A2FINISH PLAN
FINISH SCHEDULESPACE FLOOR WALLS CEILING
REMARKSROOM NO. ROOM NAME MAT. BASE NORTH EAST SOUTH WEST FIN.
153 AUDITORIUM CPT-1 RB-1 P-1 P-1 P-1 P-1 EXT R1
153A STOR. CPT-1 RB-1 P-1 P-1 P-1 P-1 EXT R1
153C STOR. CPT-1 RB-1 P-1 P-1 P-1 P-1 EXT R1
NORTH
SCALE: = 1'-0"
0 8 168
1/8"SCALE: 1/8" = 1'-0"A1FURNITURE PLAN
MA
RK
DE
SC
RIP
TIO
ND
AT
E