3

0C · 2016. 8. 23. · A 0.2C 0.2C A 1.0C A 1.0C Charging Method Maintenance & Cautions Pb Charge the batteries at least once every six months, if they are stored at 25 0 C . Float

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • Cells Per Unit

    Weight

    Terminal

    Recommended Maximum ChargingCurrent Limit

    Operating Temp.Range

    Nominal Operating Temp. Range

    Self Discharge

    Max. Discharge Current

    Internal Resistance

    6

    The batteries can be stored for more than 6 monthsat 25 . Self-discharge ratio less than 3% per monthat 25 . Please charge batteries before using.

    0C0C

    Float charging Voltage

    Equalization and Cycle Service

    13.5 to 13.8 VDC/unit Average at 250C

    014.4 C to 15.0 VDC/unit Average at 25

    Capacity

    Voltage Per Unit 12

    Approx 6.0mÙ

    960A (5 sec)

    24A

    T6

    0 025 3 C (77 5 F )

    Approx 24.0 kg

    Discharge : -20 55 C (-4 131 F)0 0Charge : 0 40 C (32 104 F)0 0Storage : -20 50 C (-4 122 F)

    80.0Ah@10hr-rate to 1.80V per cell @250C

    Container MaterialA.B.S. (UL94-HB) , Flammability resistance of UL94-V0can be available upon request.

    Constant Current Discharge Characteristics : A 0 (25 C )

    Constant Power Discharge Characteristics : W 0 (25 C )

    Dimensions

    Unit: mm 168(W) 208(H)

    Maintenance-free Battery

    General Purpose

    112-4863 (12V80Ah)

    Applications

    214(TH)

    Amps

    Watts

    RS, Professionally Approved Products, gives you professional quality parts across all products categories. Our range has been testified by engineers as giving comparable quality to that of the leading brands without paying a premium price.

    0 0

    Dimension: 259(L)

    T6 Terminal

    20

    82

    21

    42

    40

    .5

    16

    82

    210 2259 2

    M6 [0.236]

    16 [0.63]6

    [0

    .23

    6]

    1.85V/cell

    1.80V/cell

    1.75V/cell

    1.70V/cell

    1.65V/cell

    1.60V/cell

    5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20minF.V/Time

    5min 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20minF.V/Time

    1.85V/cell

    1.80V/cell

    1.75V/cell

    1.70V/cell

    1.65V/cell

    1.60V/cell

    136.9 107.6 91.5 76.6 60.9 46.1 37.7 24.0 19.0 15.5 12.5 10.9 8.84 7.55 4.12

    183.8 137.5 110.6 90.5 71.8 53.6 42.2 26.2 20.4 16.6 13.4 11.7 9.38 8.00 4.16

    207.2 151.1 120.8 97.4 74.6 55.6 44.2 27.2 20.8 16.9 13.8 12.0 9.54 8.08 4.20

    228.2 164.7 129.0 102.3 77.6 57.8 45.6 28.3 21.4 17.4 14.1 12.2 9.67 8.16 4.28

    251.6 177.8 137.2 108.7 81.9 59.3 47.1 29.1 22.3 18.0 14.5 12.5 9.82 8.33 4.34

    277.5 193.0 146.7 115.8 86.4 61.8 48.8 30.0 23.0 18.5 15.0 12.8 9.92 8.42 4.36

    250.3 198.8 170.8 144.3 116.0 88.5 72.7 46.7 37.0 30.3 24.5 21.4 17.4 14.9 8.16

    332.5 251.1 203.6 168.1 134.8 102.2 81.1 50.6 39.6 32.2 26.2 22.9 18.5 15.8 8.23

    366.9 271.5 219.7 179.1 138.8 105.0 84.4 52.3 40.2 32.8 26.8 23.4 18.7 15.9 8.30

    392.8 289.2 231.3 186.8 143.6 108.8 86.8 54.2 41.2 33.6 27.4 23.9 19.0 16.1 8.45

    427.0 309.2 244.0 197.0 150.3 110.5 89.1 55.4 42.8 34.7 28.1 24.3 19.2 16.4 8.55

    460.1 328.1 256.7 207.5 157.5 114.6 91.7 57.0 43.9 35.6 28.9 24.8 19.4 16.5 8.58

    All purpose

    Uninterruptable Power Supply (UPS)

    Electric Power System (EPS)

    Emergency backup power supply

    Emergency light

    Railway signal

    Aircraft signal

    Alarm and security system

    Electronic apparatus and equipment

    Communication power supply

    DC power supply

    Auto control system

  • Discharge Characteristics

    Cycle Life in Relation to Depth of DischargeEffect of Temperature on Long Term Float Life

    Float Charging Characteristics

    Battery Type

    AGMBattery

    6V&12V

    -20 -10 0 5 10 20 25 30 40 45

    46% 66% 76% 83% 90% 98% 100% 103% 107% 109%

    Discharge Current VS. Discharge Voltage

    Final DischargeVoltage V/cell

    DischargeCurrent (A)

    1.80V 1.75V 1.60V

    A 0.2C 0.2C A 1.0C A 1.0C

    Charging Method

    Maintenance & Cautions

    Pb

    Charge the batteries at least once every six months,if they are stored at 25 .0C

    Float Service:

    Equalisation charging is recommended once every 3 to 6 months using.

    Discharge 100% rated capacity.

    Charge 2.35v/cell constant voltage, maximum 0.3CA 24hrs.

    Cyclic Service:

    Temperature compensation for varying temperatures:

    -Charge voltage -3mV/Cell/degC from 25degC norm.

    Equalisation charge:

    It is recommended to check battery/Float voltage each month.

    The service life of your battery will be affected by:

    -The number of discharge cycles, depth of discharge, ambient

    temperature and charging voltage.

    Constant Voltage

    Constant Current

    -0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA

    0.1C until the voltage reaching 14.4V,then 0.1Cx4h

    TemperatureAvailable Capacity Sub ject to

    RS, Professionally Approved Products, gives you professional quality parts across all products categories. Our range has been testified by engineers as giving comparable quality to that of the leading brands without paying a premium price.

    0.5

    Battery temperature

    1

    2

    3

    456

    8

    10

    Charging voltage :

    2.25V/cell

    2068

    0C30

    8640104

    50122 OF

    Life

    exp

    ecta

    ncy(

    year

    )

    0.0525C0.1C0.205C

    0.4C

    0.6C1C

    2C

    101 2 4 6 20 40 60 2 4 6 8 10

    HMin

    8 20

    8.0

    9.0

    10.0

    11.0

    12.0

    13.0

    V

    12VBattery 0 0Temperature:25 C(77F)

    Term

    inal

    Vol

    tage

    (V)

    Discharge Time

    0 8 16 2012 24 28 32 36 40

    (V)(XCA)%

    ChargeVolume

    Charging Current

    Charging Voltage

    After 100% Discharge

    Charge Voltage

    (Constant 2.25v/cell)

    Charging Current

    4

    12.0

    13.0

    14.0

    15.0

    11.0

    0.10

    0.15

    0.20

    0.25

    0.05

    00

    10

    20

    30

    50

    40

    60

    70

    80

    90

    100

    120

    110

    Charging Time(hours)

    00.10CA-2.25V/cell temperature25 C

    After 50% Discharge

    Charged Volume

    Testing condition

    Discharging:current 0.17C (FV 1.7V/cell);

    Charging:current 0.25C max, voltage 2.45V/cell;

    Charging volume:125% of discharged capacity.

    Ca

    pcit

    y(%

    )

    120

    100

    80

    60

    40

    20

    00 200 400 600 800 1000 1200

    Number of Cycles

    Ambient Termperature:o o25 C (77 F)

    100%DOD

    50%DOD

    30%DOD

    Ò³Ãæ 1Ò³Ãæ 2