Upload
ctmtectrol
View
215
Download
0
Embed Size (px)
Citation preview
eurotron
TEST&MEASUREMENTS
MicroCal 200/200+
Software Packages
B u l l e t i n
0 8
- 4 5
. 2
E
Eurotron - One of the world leaders in high technology equipments: portable flue gas analysers - high accuracy calibrators - non-contact IR thermometers.
Speciali
Kit completiEurotron
MicroCal200/200+
has developed threesoftware packages for personalcomputer to allow the use of the highperformance, two channels
multifunction calibrators in alltheir capabilities.
It allows the user a completemanagement of the data logged withthe data logging option.
It allows the user to change the
LOGMAN
LINMAN
calibrator linearization data, for specialsensors or for any other need of a customlinearization.
It allows to install in the calibration the datato calibrate process instruments directly onfield for a complete plant monitoring.
, using this software isable to perform a completely automatedcalibration procedure storing the “before”and the “after” calibration data.
CALPMAN
MicroCal 200/200+
CalpMan
LogMan
LinMan
eurotron
EUROTRON Italiana S.r.l.V.le F.lli Casiraghi 409/413I 20099 Sesto S. Giovanni (MI)tel. +39-02 248820.1 fax +39-02 2440286
Distribuited by:
CALIBRATION PROCEDURE MANAGER
CALPMAN
Standard Agencies and Quality Auditors require thecollections, organization and analysis of traceabilitydocuments. is available to transfer a selectionof calibration routines from a PC to the internal memoryof the instrument in order to simplify field calibrationsselecting the appropriate tag number.When a plant has a large number of process instruments,the needs for checks and field calibrations are reallyimportant to keep the compliance with ISO 9000requirements.Eurotron with , coupled with the powerful
calibrator, gives you the possibility to keepthese instruments under control.
The data of each calibration procedure can be stored,into the calibrator RAM, together with the TAG name,engineering units, process info, calibration points and atwo levels allowed error band.The calibrator can be used as a generator, as a recorder or both; its input and output terminals can be used to generate,receive and compare info.
After the calibration check, will indicate if the checked instrument is within its specifications or it has to becalibrated, and a decision can be made directly by the plant technicians.The status of every instrument before and after its calibration can be stored and recalled later for yor traceabilitydocument.
Calpman
CALPMANMicroCal 200
MicroCal 200
Benefits to be gained from this system are:By keeping a record of the time required between necessary adjustment,
the optimum maintenance period can be determined.. A calibration report for each TAG can be printed.
. Data can be used to analyze the time and cost required for instrument calibration andaid in planning manpower, specifying supplier, etc.
!
!
!
Optmisation of the Maintenance period.
Print Calibration reportsAid in maintenance planning
LOGGING DATA MANAGER
LOGMAN
The LOGMAN program is used to manage the data comingfromthe MicroCal 200 memory. These data can be downloaded,viewed as numerical values or in a graphical mode, savedondisk, printed and exported to be used with the most commonspredsheets.The program is designed as a list of options selectablepressingthe appropriate number on the keyboard. In this way, theuse of the program is possible also by those people who are notpractical in personal computing.
LINEARIZATION DATA MANAGER
LINMAN
As doesn't cover the whole range of sensors (thermocouple or resistance thermometers), but the mainones, gives the user the possibility of creating its own sensor linearizations and to use them with .With LINMAN it is possible to enter °C/signal points for the thermocouples and °C/signal for the Rtd's and it is alsopossible to enter engeneering unit/signal points.LINMAN will provide the linearization by interpolating the inserted points.In this way, by downloading the data into , it will be possible, by selecting Pt X ot Tc X, to use the speciallinearized sensor both in simulation and measurement.The program structure is the same than LOGMAN's, with a list of options that are enabled by pressing the appropriate number on the keyboard.
MicroCal 200Eurotron MicroCal 200
MicroCal 200