68
© 2011 BouMatic. LIT00253EN.1201 1 Cooling Dealer Catalog Cooling Tanks Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region. Glacier Milk Cooler Setting the industry standard for quality, precision and durability for over 70 years Glacier milk coolers from BouMatic deliver the industry’s most advanced design and engineering for smooth running dependability. Built with precision-engineered evaporator plates, the Glacier delivers the perfect balance of maximum cooling, consistent pressure drops, uniform refrigerant distribution and efficient oil return. This means the most cost-efficient operation for your dairy. Maximum cooling efficiency, durability Glacier cooling plates are positioned across the entire lower section of a tank. This allows for maximum cooling efficiency from the entire cooling plate group from your first to last milking session. Highest Quality Construction Tough and Durable Heavy Gauge Stainless Steel Smoothest Running System Precision Engineered

04_Cooling

Embed Size (px)

DESCRIPTION

Dealer Catalog

Citation preview

Page 1: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk CoolerSetting the industry standard for quality, precision and durability for over 70 years

Glacier milk coolers from BouMatic deliver the industry’s most advanced design and engineering for

smooth running dependability.

Built with precision-engineered evaporator plates, the Glacier delivers the perfect balance of maximum cooling,

consistent pressure drops, uniform refrigerant distribution and efficient oil return. This means the most

cost-efficient operation for your dairy.

Maximum cooling efficiency, durability

Glacier cooling plates are positioned across the

entire lower section of a tank. This allows for

maximum cooling efficiency from the entire

cooling plate group from your first to last

milking session.

• Highest Quality Construction

• Tough and Durable

• Heavy Gauge Stainless Steel

• Smoothest Running System

• Precision Engineered

Page 2: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

A B

F GHP

L

H

C D

E

W

O

N

J K M

**

Glacier™ Milk Coolers

Glacier™ Cooler Specifications

* Add 7 inches to overall length for drain valve, 11 inches for tank mounted ladder all sizes. ** 3000-8000 gallon Glacier™ coolers have two agitators. To locate both indoors when bulkheading a cooler use the

following dimensions for coolers: 3000, 5000 = 49 inch; 4000, 6000, 7000 and 8000 = 59 inch. § Capacity is no less than indicated. @ (Dimensions are in inches and are not certified — tolerance of ± 1.5%). P Temperature recorder sensor mounting access location. Dimension is center of 10.25 inches long access opening. O Indicates “Minimum” dimension which will place one or both agitators outside the milk house on 2500-8000

gallon coolers.Note: Part number relates to cooler. Does not include controller, milk valve or condensing units.

CAPACITY § DIMENSIONS (INCHES)@ SHIPPING@Gals Liters Lb Milk Part No. L* W A B C D E F G H J K M N O P Legs L W H Wt

600 2300 5160 4791314 75 60 57 59 76 78 32 13.5 14.5 47 37.75 37 32.25 30 4 89 72 74 1000

800 3000 6880 4791329 97 60 57 60 76 78 32 13 14 35 37.75 59 32.25 30 6 109 72 74 1260

1000 3800 8600 4791339 120 60 57 61 76 78 32 12.5 13.5 47 37.75 82 32.25 30 6 132 72 74 1300

1250 4800 10750 4791343 101 71 69 73 88 90 32 13 14 37 37.75 63 32.25 30 6 126 90 84 1620

1500 5700 12900 4791354 120 71 69 73 88 90 32 12.5 13.5 47 37.75 82 32.25 30 6 132 90 87 1940

2000 7700 17200 4791364 120 85 77 80 96 97 48 14 15 45.5 37.75 82 32.25 30 6 132 89 96 2240

2500 9800 21500 4791830 143 86 80 84 100 101 48 19.5 19.5 51.5 64.50 77.5 59 32 41 6 158 89 96 2650

3000 11600 25800 4791835 169 86 80 85 100 101 48 18.5 18.5 44 54.50 55 59.5 49 32 48 8 185 89 96 3100

4000 15200 34400 4791840 224 86 81 86 100 101 48 23.5 23.5 44 54.50 104 64.5 49 32 53 10 239 89 96 3900

5000 19000 43000 4791845 202 101.5 93 98 112 113 56 25 25 38 56.00 90 56 50.5 33 73 10 216 102 111 4160

6000 22700 51600 4791850 242 101.5 93 99 112 113 56 25 27 38 66 110 66 60.5 33 73 12 256 102 111 4840

7000 26500 60200 4791855 240 107 102 108 121 122 60 27 27.5 37 64 107 68.5 58.5 31 73 12 255 107 121 5350

8000 30300 69000 4791860 280 107 102 109 121 122 60 25 27 38 66 148 66 60.5 33 73 14 294 107 121 6540

Codes for certification of milk coolers vary by location. Contact your local sanitarian or other regulatory official to determine what will be necessary to meet local codes. The following items should be addressed and supplied as required.

• Above part numbers meet 3-A standards• Approved outlet valves• External calibration on coolers 2000 gallons or greater• Temperature recorders (48 hour or 7 day)• Charts in Gallons, Liters, Kilograms, etc

Page 3: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers continued

Glacier™ Milk Cooler Components Ordering GuidelinesMilk Cooler Options

Cooler assemblies include 1 Hp wash pump and fittings (600 gallons - 2000 gallons) or 1.5 Hp wash pump and fittings

(2500 gallons - 8000 gallons), ladders, manhole cover and gasket, agitator(s) and blade(s), internal measuring stick and

chart, and packed parts and other accessory options.

Milk Valve Kit• Use 2 x 2 inch Valve Kits for coolers with 2 inch milk outlets. 600 gallons through 800 gallons

• Use 3 x 3 inch Valve Kits for coolers with 3 inch milk outlets. 1000 gallons through 8000 gallons

• 2 x 3 inch valve and adapter kit intended when using 2 inch valves on 1000 gallons through 4000 gallons coolers with 3 inch milk outlets.

NOTE: See page 10 for options.

Cooler / Wash control

Deco-Matic™ III or Glacier-Guard Dari-Chem™ unitNOTE: See pages 5 and 6 for options.

Condensing UnitsRefer to ordering guide section pages 11 through 34. Also see Refrigeration Sizing Tool on Dealer Portal for complete sys-tem sizing and component selection. Optional items to complete your Glacier Cooler installation:

• Refrigeration line sets on Page 36• Agitator weatherproof kits on Page 9• External calibration kits on Page 8• Additional rear fill (special order) on Page 9• Bulkhead kits on Page 9• Glacier-Guard charts and printer on Page 5• Chart recorder on Page 38• Extended 5-year compressor warranties on Page 35• Suction manifold and liquid line distributor on Page 36• Pumpdown kits and voltage protection modules on Page 35 • Therma-Stor heat recovery units on Page 61

Cooling System Sizing ToolPlease refer to the “Refrigeration Sizing Tool” located on the Boamatic Dealer Portal to accurately select and size the proper cooling system components, customized to your customers application. The Refrigeration Sizing Tool can be found at:

• Log in to Dealer Portal

• Select “Dealer Resources”

• Select “Tools”

• Select “Refrigeration Sizing Tool”

Page 4: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers continued

Glacier™ Custom PackagesGlacier™ Cooler, Less ControllerChoose the size of cooler desired. (Refer to cooler and condensing unit selection charts.) For cooler size specifications, refer to DKF specification chart. Cooler assemblies without controller include:

• Agitator(s) and blade(s)• External ladder• Wash pump package• Internal wash water fill tubes in-

cluded on 600-4000 gallons coolers• Packed parts• Manhole cover gasket• Internal ladder (2500-8000 gallons)• Internal measuring stick and chart• 60 Hz agitators and wash pumps• 2 inch threaded milk outlets standard on 600-1500 gallon coolers• 3 inch threaded milk outlets standard on 2000-8000 gallon coolers• Additional 3 inch front-fill with vent standard on all 5000-8000 gallon coolers

Average Btuh Capacity Range of Milk Coolers Under Normal Operating Conditions.Cooling rate varies according to actual milk temperature in cooler and condensing temperature and compressor(s) used. Use this chart to help choose the most efficient condensing unit(s) for your application.

600—800 gal Single Evaporator Circuit 1000—3000 gal Dual Evaporator Circuits 4000—8000 gal Four Evaporator Circuits

TANK SIZE (GALLONS)

OPTIMUM BTU’S PER TANK CIRCUITS

600 45,000 Btuh 1 circuit800 60,000 Btuh 1 circuit1000 76,000 Btuh 2 circuits (38,000 Btuh/ea.)1250 80,000 Btuh 2 circuits (40,000 Btuh/ea.)1500-2000 97,000 Btuh 2 circuits (48,500 Btuh/ea.)2500 115,000 Btuh 2 circuits (57,500 Btuh/ea.)3000 137,000 Btuh 2 circuits (68,500 Btuh/ea.)4000 182,000 Btuh 4 circuits (45,500 Btuh/ea.)5000 160,000 Btuh 4 circuits (40,000 Btuh/ea.)6000 196,000 Btuh 4 circuits (49,000 Btuh/ea.)7000 194,000 Btuh 4 circuits (48,500 Btuh/ea.)8000 229,000 Btuh 4 circuits (57,250 Btuh/ea.)*Note: Use optimum Btuh values to help choose compressor sizes for custom cooling installations. Optimum Btuh values are not minimum or maximum capacities. They are optimum suggested values based on normal average condensing unit capacities when operating in typical milk cooling applica-tions through expected temperature operating ranges. Larger or smaller compressors, within reason, can be used with corresponding results when based on actual operating temperatures.

Refer to actual Btuh rating for specific compressor and operating range for your specific application.

Total Pounds of Milk x Temperature Drop (F) = Total BTUs Milk Time + 1/2 hour = Compressor Run Time Total Btuh / Compressor Run Time = Btuh 1 Gallons of Milk = 8.6 Pounds

O R D E R I N F O R M A T I O NGlacier Coolers™600 gallons/2300L 4791314800 gallons/3000L 47913291000 gallons/3800L 47913391250 gallons/4800L 47913431500 gallons/5700L 47913542000 gallons/7700L 47913642500 gallons/9500L 47918303000 gallons/11600L 47918354000 gallons/15000L 47918405000 gallons/19000L 47918456000 gallons/22700L 47918507000 gallons/26500L 47918558000 gallons/30300L 4791860

Page 5: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers continued

Glacier-Guard™ Automatic Cooler/Wash ControlDimensions of each control and pump module is 19 inch w x 8 inch h x 6.5 inch d (48.3 cm x 20.3 cm x 16.5 cm).

Package includes:

• Chemical injection manifold 10 inch w x 5.5 inch h x 2.5 inch d (25.4 cm x 13.9 cm x 6.3 cm) with chemical check valves and fittings

• Electronic tank mounted temperature probe

• 40 feet of chemical tubing

External water solenoid valves (two required) are not included and must be purchased separately.

Glacier-Guard/PC Interface Software Allows PC interface to be downloaded so data collected in the Glacier-Guard Control can be recorded, displayed and/or printed in graph form using your PC and printer.

Serial Printer KitThis roll printer is capable of providing a real-time hard-copy “strip-chart” temperature graph and wash cycle information, that the dairy opera-tor or the milk hauler can use to document the storage temperature of the milk in the cooler and CIP information. Kit includes serial printer, 100-240V power supply, 1 paper roll, RS-232 serial cable assembly to the Glacier-Guard & Gaurdian II control assemblies.

O R D E R I N F O R M A T I O NGlacier-Guard Automatic Cooler/Wash ControlPump Module and Chemical Manifold 4023262Switch, Water Flow, Chemical (optional) 85018521/2 inch NPT water solenoid valve, 220V 85030753/4 inch NPT water solenoidvalve, 220V 8503076

0091043 - Glacier-Guard/PC Interface Software

4023262 - Glacier-Guard Automatic Cooler/Wash Control, Pump Module and Chemical Manifold

O R D E R I N F O R M A T I O NGlacier-Guard PC InterfaceSoftware CD 0091043Cable Assy., RS-232 3555509

O R D E R I N F O R M A T I O NKitIncludes, Printer, 100-240v, W/Serial Cable, 1 roll of paper & Ribbon 3561976Printer, 100-240v 3561977Power Supply, 100-240v 3561978Cable Assem, Serial, PS2 3561979Ribbon, Printer, STD, Black 3561980Paper, Printer, Roll 3561981

Sample graphs using BouMatic interface software and your PC.

Information usedfor diagnostics

3 missed wash cycles

poweroutage

Date, time, dairy name and dairy ID is stamped at the beginning and end of the milk temperature graph.

All wash parameters of all wash phases are printed during each wash cycle.

4023739 - Serial Printer/PROM Kit

Temperature recordinginformation

wash cycles

milktemperature

Page 6: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

O R D E R I N F O R M A T I O NDari-Chem™ Dari-Chem (for milk coolers) Includes Chemical Manifold with water flow switch 4022784Dari-Chem Pipeline Washer Kit with fill switch and Support Arm Kit 8502705

Glacier™ Milk Coolers continued

Deco-Matic™ III Cooler Control with Tank Mounted Mechanical ThermostatAssembly includes tank mounted mechanical thermostat, necessary for the proper operation of the Deco-Matic III control and the milk cooler condensing units.

20.5 inch w x 20 inch h x 10 inch d (52 cm x 50.8 cm x 25.4 cm) with jars attached. Deco-Matic III 50-60 Hz, 230V.

Dari-Chem™ Programma-ble Liquid Chemical Dispensing UnitThree independently programmable peristal-tic pumps economically dispense chemicals for milk coolers and milking systems.

Dari-Chem Dimensions

6 inch h x 13.75 inch w x 6.75 inch d (15.2 cm x 35 cm x 17 cm)Note: For all milk cooler applications, the chemical manifold

with flow switch must be installed in the cooler’s water fill line.

O R D E R I N F O R M A T I O NDeco-Matic™ Control Deco-Matic III and Thermostat 4023709Tank Mounted Thermostat 4022871

4023709 - Deco-Matic™ III Cooler Control with Tank Mounted Thermostat Assy.

4022784 - Dari-Chem and

Chemical Manifold with

water flow switch

Page 7: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 7

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers continued

RPZ Backflow Preventer Reduced Pressure Zone (RPZ) Backflow Preventers are designed to protect potable water supplies in accordance with plumbing codes and water utility authority requirements. Consult local plumbing codes and or authorities for compliance regulations. Intended to be used in Glacier-Guard and Dari-Chem installations.

Pneumatic Cooler Wash Drain Slide Valve Kit Includes 1-1/2 inch pneumatic cooler wash drain valve, 220V dual action air solenoid, air line and air line fittings. Designed to replace existing water pressure activated diaphragm disc drain valve, or to be used on cooler wash drain manifold kit.

Adapter Assembly, Cooler, Wash Fill Wash/Fill Adapter enables a cooler to be filled with wash water faster by eliminating the flow restrictions which occur with diaphragm operated drain valves.

The wash/fill adapter can accept either 1/2 inch or 3/4 inch water supply hoses for greater wash water volumes and shorter wash times.

4023353 - 1/2 inch RPZ Backflow Pre-venter

O R D E R I N F O R M A T I O NRPZ Backflow Preventer 1/2 inch RPZ Backflow Preventer 4023353

O R D E R I N F O R M A T I O NValve Kit 1-1/2 inch Pneumatic Wash Drain Slide Valve Kit 4023924

O R D E R I N F O R M A T I O NAdapter Assembly, Cooler, Wash Fill 4024593

4023924 - 1-1/2 inch Pneumatic Wash Drain Slide Valve

These two Glacier-Guard options are designed to replace the two pressure operated drain valves on all large Dari-Kool coolers having 1 1/2 hp. wash pump systems (2500 gallons to 8000 gallons coolers) and using a Glacier-Guard cooler wash control.

4024593 - Adapter assembly, cooler, wash fill

Page 8: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 8

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers continued

External Calibration KitCurrently required by 3-A on coolers 2000 gallons and larger. This kit provides a convenient method of measuring contents of larger bulk coolers. All kits are designed to be field installed and calibrated. External chart will be generated and sent to dealer after field comparison to internal stick is received by BouMatic.

Milk Valve Reducer• Used to convert larger milk valves to a smaller

pickup truck hose.• Also used to mount 2 inch x 2 inch

valves to coolers having 3 inch outlets.

Air Blow Milk Valve AssemblyFor use in bottom-fill installations. Kit includes 1-1/2 inch Y-check milk valve with tri-clamp fittings and air blow check valve assembly. Consult local sanitarians and/or inspectors for approval of specific application and installation.

Air Blow Valve KitFor use in milk supply line outlet.

Air Blow Timer/Valve KitFor use with air blow check valve, or 1-1/2 inch stainless tee on output of receiver milk pump. Kit includes 230V pneumatic solenoid valve and adjustable timer.

“Y” Check ValveFor use in milk supply line near cooler milk valve. Used in bottom fill applications.

4020209 - External Calibration Kit

O R D E R I N F O R M A T I O NEccentric Reducer3 x 2 inch Eccentric ReducerStainless Steel* 4019409

O R D E R I N F O R M A T I O NAir Blow Milk Valve AssemblyValve Assembly Air Blow, 1-1/2 inch 8516840

8516840 - Valve Assembly Air Blow, 1-1/2 inch

O R D E R I N F O R M A T I O NExternal Caliration Kit External Calibration Kit, mm 2000 gallons 4020209External Calibration Kit, mm 2500/4000 gallons 4020208External Calibration Kit, mm 5000/6000 gallons 4020207External Calibration Kit, inch7000 gallons 4024048External Calibration Kit, mm 8000 gallons 4020635

O R D E R I N F O R M A T I O NAir Blow Valve KitAir Blow Valve Kit, 1-1/2 inch 8516112Air Blow Valve Kit, 2 inch 8516841

O R D E R I N F O R M A T I O N“Y” Check Valve“Y” Check Valve, 1-1/2 inch 8516838“Y” Check Valve, 2 inch 8516839

O R D E R I N F O R M A T I O NAir Blow Timer/Valve KitAir Blow Timer/Valve Kit 8516132

8516132 - Air Blow Timer/Valve Kit

4019409 - 3 x 2 inch Eccentric Reducer

8516112 - Air Blow Valve Kit

8516838 - Y Check Valve

Page 9: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 9

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers continued

Bulkhead AccessoriesTo allow a larger cooler to be installed into an existing milkhouse without the expense of building a new structure or enlarging the present one. To figure space requirements, refer to Cooler Specification Table on page 2.

Weatherstrip Bulkheading Kit

Agitator Weatherproof KitFor all coolers where agitator is exposed to elements due to bulkheading and requires weatherproof seal.

Rear Fill InletsAdditional rear milk fill pipe is available. Specify exact size, location and length of rear fill required special order. Standard rear fill inlets are 3 inch diameter to allow another vent lid to be attached. Vent lid included. Unless specified, rear fill will be installed on center top of cooler, 12 inches in from rear head. Other pipe sizes and/or locations are available upon request.

Drip Shield, DKF Style Tank (2000 gallons or less)Used to shield condensation from entering bulk tank from the 1.5 inch milk pipe.

Rubber Dipstick Handle Cover/SlingerThis rubber slinger is designed to replace the standard stainless steel dipstick handle cover and fits securely over the dipstick handle. This cover will not dislodge from the dipstick handle during the wash cycle, which may be a concern on some coolers.

OptionsSome accessories and options are required for various regulations and codes. Check with local officials for complete and special considerations that apply to your area.

4016641 - Bulkhead Accessory

O R D E R I N F O R M A T I O NWeatherstrip Bulkheading Kit2000 gallons 40166412500-8000 gallons 4016642

Agitator Weatherproof Kit2500-8000 gallonsnew series coolers 4024220600-2000 gallons coolers 2500-8000 gallons old series coolers 4016496

Real Fill InletsAdditional Rear Fill(special order) 4024343

Drip Shield, DKFFor all sizes DKF Coolers 4012720

Rubber SlingerRubber Slinger 4070283

SPONGE INSULATION

STAINLESS 10 inch

4016496 - Agitator Weatherproof Kit, old series

4024220 - Agitator Weatherproof Kit, new series

4012720 - Drip Shield

4070283 - Rubber Slinger

Page 10: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 0

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Milk Drain Valves

Milk Valve PackagesChoose the size required in either standard or New York State approved styles. 3 x 3 inch milk valves are required on coolers 5000 gallons or larger. All valves are duplex-threaded and are sliding plunger, tee-valve style.

Valve/Adapter Kit, 2 x 3 inchUse on 2000-4000 DKF Coolers having three inch drains. Kit allows standard two-inch valve and wash pump package to be used on these coolers. Kit includes a 2 x 2 inch (PN 4013833) milk valve, wash line hanger, 2 x 3 inch eccentric reducer, a 2 inch and 3 inch gasket, 3 inch nut, and a 4.25 inch hex wrench.

Butterfly Cooler Milk Drain Valve KitsButterfly cooler milk drain valve kits include butterfly drain valve, threaded both ends, with locking handle, “J” bend wash tube extension, nuts and gaskets, wash line hanger, wrench, etc. 3 x 3 inch kit also includes 3 x 2 inch stain-less eccentric reducer. (Butterfly valves do not carry 3-A approval marking).

2 inch Threaded Drain PlugThreaded plug, includes chain, used to seal end of wash tube on coolers when not in CIP mode (in place of brush).

4024308 - 2 x 2 inch Butterfly Milk Drain Valve, Kit

4024170 - 3 x 3 inch Butterfly Milk Drain Valve Kit

Typical 3 inch Butterfly Valve Kit Installation

4019499 - 3 x 3 inch Milk Valve

O R D E R I N F O R M A T I O NMilk Valve Packages3 x 3 inch, used on 2000- 8000 gallons cooler, supplied with 3 x 2 inch outlet reducer. N.Y. Approved 40194992 x 2 inch N. Y. StateApproved 600-4000 4015856

O R D E R I N F O R M A T I O NValve/Adapter KitValve/Adapter Kit, 2 x 3 inch 4022872

4022872 - Valve/Adapter Kit, 2 x 3 inch4024500 - 2 inch Threaded Drain Plug

O R D E R I N F O R M A T I O NButterfly Milk Drain Valve Kit3 x 3 inch Butterfly Milk Drain Valve, Kit (use on2000 gallons to 8000 gallons milk coolers) 40241702 x 2 inch Butterfly Milk DrainValve Kit (use on 600 gallons to1500 gallons milk coolers) 4024308

O R D E R I N F O R M A T I O NThreaded Drain Plug2 inch Threaded Drain Plug 4024500

Page 11: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 1

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

TTR - Time & Temperature Recorder

Time & Temperature RecorderPeace of Mind

Take comfort in knowing your milk is monitored 24/7. The BouMatic TTR provides a full menu of alarms designed to protect your milk, and your livelihood.

• Cooling alarms • Tank alarms• Pipeline alarms• System alarms• Data tracking

Advantage BouMaticThe BouMatic TTR is the only alarm device that monitors and gives alarms for each individual phase of the wash cycle. Other products simply give an alarm with no specifics.

The BouMatic TTR also offers the most extensive data tracking available. Only BouMatic stores your cooling and wash data for one year, giving you instant access to your past operating conditions.

Engineered and Built with PLC Technology• Full color touch screen controls - no tradi-tional switches or buttons• Input and Output hardware diagnostics• Industrial strength construction for years of reliable service

O R D E R I N F O R M A T I O NTTR QC Panel 4029086Agitator shaft prox switch 4040078Remote signal towerLED option 4029148Tank wash temperatureSensor (optional) 4023261120 VAC Relay 4040076240 VAC Relay 402915024 VDC Relay 4040077Remote signal towerred LED light option& buzzer 4029149Whisker Switch 4017304

Page 12: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 2

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

TTR - Time & Temperature Recorder

Time & Temperature RecorderBouMatic P/N

Relays must be matched to the input voltage for the following inputs. See the installation manual for details on wiring

Temperature Sensors:

Relays:

Alarms: The following alarm products are optional and are not part of the base TTR

Switches: The following switches are optional and are not part of the base TTR

4029150 Factory Installed 230 VAC Relays (included in base P/N)

4040076 Field Replacement 120 VAC Relays

4040077 Field Replacement 24 VDC Relays

4029086

Time Temperature Recorder Includes:

230 VAC Relays for all inputs, quantity 8

Temperature Sensor for Bulk Tank, quantity 1

Temperature Sensor for Pipeline, quantity 1

4029148 Alarm Light Only

4029149 Alarm Light and Buzzer

4040078Proximity switch to mount on the agitator shaft, as an alter-

native to connecting to the agitator motor actuator

4017304Whisker Switch for pipeline wash or milk position sensing. As an alternativeto using a switch in the master control panel

4023261Temperature Sensor for Bulk Tank (1 included with TTR)

Optional: 2nd Probe to better monitor tank’s washing tem-peratures

8516995 Temperature Sensor for Pipeline (1 included with TTR)

Page 13: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 3

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Module Assemblies

Scroll Compressors

• Easy to install and maintain• Fixed low/high pressure switch• Pump down switch• Sealed liquid line filter drier

and sight glass• Compressor contactor

and control circuit fusing• Compressor and control

circuit breaker• Suction accumulator• Sealed suction filter• Liquid line solenoid valve• Crankcase heater• Oil separator with discharge check

valve and oil return hand valve (only available on 7.5 Hp, 9 Hp and 10 Hp)

• All units are R-404a and R-507 compatible

O R D E R I N F O R M A T I O NScroll Compressor3 Hp, 208/230V, 1Ph, 50/60 Hz 40401673 Hp, 208/230V, 3Ph, 50/60 Hz 40401823 Hp, 380/460V, 3Ph, 50/60 Hz 40401834 Hp, 208/230V, 1Ph, 50/60 Hz 40401704 Hp, 208/230V, 3Ph, 50/60 Hz 40401694 Hp, 380/460V, 3Ph, 50/60 Hz 40401685 Hp, 208/230V, 1Ph, 50/60 Hz 40401735 Hp, 208/230V, 3Ph, 50/60 Hz 40401725 Hp, 380/460V, 3Ph, 50/60 Hz 40401716 Hp, 208/230V, 3Ph, 50/60 Hz 40401756 Hp, 380/460V, 3Ph, 50/60 Hz 40401747.5 Hp, 208/230V, 3Ph, 50/60 Hz 40402087.5 Hp, 380/460V, 3Ph, 50/60 Hz 40402099 Hp, 208/230V, 3Ph, 50/60 Hz 40402339 Hp, 380/460V, 3Ph, 50/60 Hz 404023410 Hp, 208/230V, 3Ph, 50/60 Hz 404023510 Hp, 380/460V, 3Ph, 50/60 Hz 4040236

DIMENSIONS IN. (CM)APPROX. NET WT.

LBS. (KG)PART

NUMBERHEIGHT WIDTH DEPTH RLA

28 (71.12) 25 (63.5) 29 (73.66) 186 (84.37) 12.2 404018228 (71.12) 25 (63.5) 29 (73.66) 186 (84.37) 6.4 404018328 (71.12) 25 (63.5) 29 (73.66) 186 (84.37) 18.6 404016728 (71.12) 25 (63.5) 29 (73.66) 207 (93.90) 7.4 404016828 (71.12) 25 (63.5) 29 (73.66) 207 (93.90) 13.5 404016928 (71.12) 25 (63.5) 29 (73.66) 207 (93.90) 24.0 404017028 (71.12) 25 (63.5) 29 (73.66) 226 (102.51) 8.7 404017128 (71.12) 25 (63.5) 29 (73.66) 226 (102.51) 19.2 404017228 (71.12) 25 (63.5) 29 (73.66) 226 (102.51) 28.5 404017328 (71.12) 25 (63.5) 29 (73.66) 241 (109.32) 22.8 404017428 (71.12) 25 (63.5) 29 (73.66) 241 (109.32) 8.3 404017543-1/2 (110.49) 35-19/50 (89.87) 47 (119.38) 194 (88) 27.6 404020843-1/2 (110.49) 35-19/50 (89.87) 47 (119.38) 194 (88) 14.7 404020943-1/2 (110.49) 35-19/50 (89.87) 47 (119.38) 195 (88.5) 26.9 404023343-1/2 (110.49) 35-19/50 (89.87) 47 (119.38) 195 (88.5) 15.7 404023443-1/2 (110.49) 35-19/50 (89.87) 47 (119.38) 354 (160.57) 37.2 404023543-1/2 (110.49) 35-19/50 (89.87) 47 (119.38) 354 (160.57) 17.9 4040236

Scroll Compressor Module

Page 14: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 4

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condenser Assemblies

Air-Cooled Condenser

• Designed for efficient performance and low maintenance

• Ambient or pressure activated fan cycling

• Variable speed lead fan motor

• All units are R-404a and R-507 compatible

O R D E R I N F O R M A T I O NAir-Cooled Condenser5 Hp, 208/230V, 1Ph, 50/60 Hz 40402025 Hp, 208/230V, 3Ph, 50/60 Hz 40402045 Hp, 380/460V, 3Ph, 50/60 Hz 40402036 Hp, 208/230V, 1Ph, 50/60 Hz 40402056 Hp, 208/230V, 3Ph, 50/60 Hz 40402076 Hp, 380/460V, 3Ph, 50/60 Hz 40402067.5 Hp, 208/230V, 3Ph, 50/60 Hz 40402107.5 Hp, 380/460V, 3Ph, 50/60 Hz 404021110 Hp, 208/230V, 3Ph, 50/Hz 404023710 Hp, 380/460V, 3Ph, 50/60 Hz 4040238

DIMENSIONS INCHES (CM)APPROX. NET WT.

LBS. (KG) RLAPART

NUMBERWIDTH DEPTH

39-3/4 (100.97) 30 (76.2) 180 (81.65) 3.4 404020239-3/4 (100.97) 30 (76.2) 180 (81.65) 1.3 404020339-3/4 (100.97) 30 (76.2) 180 (81.65) 2.6 404020449-3/4 (126.37) 40 (101.6) 260 (117.93) 3.9 404020549-3/4 (126.37) 40 (101.6) 260 (117.93) 1.3 404020649-3/4 (126.37) 40 (101.6) 260 (117.93) 2.6 404020769-3/4 (177.17) 60 (152.4) 450 (204.12) 5.2 404021069-3/4 (177.17) 60 (152.4) 450 (204.12) 2.6 404021169-3/4 (177.17) 60 (152.4) 470 (213.19) 5.2 404023769-3/4 (177.17) 60 (152.4) 470 (213.19) 2.6 4040238

Air-Cooled Condenser

Page 15: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 5

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Water-Cooled, Scroll

• Water regulating valve provides superior head pressure control

• Extra capacity receiver with liquid shut-off valve is provided for installations with long refrigerant lines

• Pumpdown switch for field servicing• Schrader valves permit recovery of

refrigerant isolated in compressor for quick and easy compressor change

• Encapsulated, automatic reset, high pressure control and an adjustable low pressure control with flexible refrigerant hose to reduce possibility of leaks

• Sight glass is easily viewable from the front to monitor the refrigerant charge

• Suction filter installed for additional system protection

• All units are R-404a and R-507 compatible

O R D E R I N F O R M A T I O NWater-Cooled, Scroll3 Hp, 208/230V, 1Ph, 50/60 Hz 40402203 Hp, 208/230V, 3Ph, 50/60 Hz 40402213 Hp, 380/460V, 3Ph, 50/60 Hz 40402224 Hp, 208/230V, 1Ph, 50/60 Hz 40402234 Hp, 208/230V, 3Ph, 50/60 Hz 40402244 Hp, 380/460V, 3Ph, 50/60 Hz 40402255 Hp, 208/230V, 1Ph, 50/60 Hz 40402265 Hp, 208/230V, 3Ph, 50/60 Hz 40402275 Hp, 380/460V, 3Ph, 50/60 Hz 40402286 Hp, 208/230V, 3Ph, 50/60 Hz 40402296 Hp, 380/460V, 3Ph, 50/60 Hz 40402307.5 Hp, 208/230V, 3Ph, 50/60 Hz 40402317.5 Hp, 380/460V, 3Ph, 50/60 Hz 4040232

DIMENSIONS INCHES (CM)APPROX. NET WT.

LBS. (KG)PART

NUMBERHEIGHT WIDTH DEPTH RLA

29 (73.66) 25 (63.5) 28 (71.12) 171 (77.56) 14.7 404022029 (73.66) 25 (63.5) 28 (71.12) 171 (77.56) 9.9 404022129 (73.66) 25 (63.5) 28 (71.12) 171 (77.56) 5.1 404022229 (73.66) 25 (63.5) 28 (71.12) 207 (93.90) 24.0 404022329 (73.66) 25 (63.5) 28 (71.12) 207 (93.90) 13.5 404022429 (73.66) 25 (63.5) 28 (71.12) 207 (93.90) 7.4 404022529 (73.66) 25 (63.5) 28 (71.12) 226 (102.51) 28.8 404022629 (73.66) 25 (63.5) 28 (71.12) 226 (102.51) 19.2 404022729 (73.66) 25 (63.5) 28 (71.12) 226 (102.51) 8.7 404022829 (73.66) 25 (63.5) 28 (71.12) 241 (109.32) 21.5 404022929 (73.66) 25 (63.5) 28 (71.12) 241 (109.32) 8.3 404023047 (119.38) 36 (91.44) 44 (111.76) 271 (122.93) 30.7 404023147 (119.38) 36 (91.44) 44 (111.76) 271 (122.93) 16.4 4040232

Water-Cooled Scroll Compressor Module

Page 16: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 6

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies continued

Air-Cooled, Scroll

• With HyperCore™ microchannel coil technology

• Painted steel cabinets for su-perior strength and corrosion protection

• Suction service valves located outside the cabinet for quick installations

• Receiver with fusible plug, liquid shutoff valve and charging port

• Unit stays on if the hood is removed for servicing

• Sight glass is easily viewable

• Encapsulated, auto-reset, high and low pressure controls to eliminate leaks

• Discharge service valves• Adjustable low pressure control• Variable speed EC (VSEC) motors with Orbus™

controller (except 380/460V, 3Ph units)• Liquid line drier, sight glass• Liquid line solenoid valve and pumpdown switch• Suction accumulator and line filter• All units are R-404a and R-507 compatible

O R D E R I N F O R M A T I O NAir-Cooled, Scroll3 Hp, 208/230V, 1Ph, 50/60 Hz 40401663 Hp, 208/230V, 3Ph, 50/60 Hz 40401653 Hp, 380/460V, 3Ph, 50/60 Hz 40401644 Hp, 208/230V, 1Ph, 50/60 Hz 40401524 Hp, 208/230V, 3Ph, 50/60 Hz 40401514 Hp, 380/460V, 3Ph, 50/60 Hz 40401505 Hp, 208/230V, 1Ph, 50/60 Hz 40401555 Hp, 208/230V, 3Ph, 50/60 Hz 40401545 Hp, 380/460V, 3Ph, 50/60 Hz 40401536 Hp, 208/230V, 3Ph, 50/60 Hz 40401576 Hp, 380/460V, 3Ph, 50/60 Hz 40401567.5 Hp, 208/230V, 3Ph, 50/60 Hz 40402577.5 Hp, 380/460V, 3Ph, 50/60 Hz 4040258

DIMENSIONS INCHES (CM)APPROX. NET WT.

LBS. (KG)PART

NUMBERHEIGHT WIDTH DEPTH RLA

30-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 7.4 404015030-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 13.5 404015130-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 24.0 404015230-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 8.7 404015330-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 19.2 404015430-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 28.8 404015530-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 8.3 404015630-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 317 (143.79) 21.5 404015730-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 287 (130.18) 5.1 404016430-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 287 (130.18) 9.9 404016530-1/4 (76.85) 42-1/2 (107.95) 29-3/4 (75.57) 287 (130.18) 14.7 404016636-3/4 (93.35) 63-3/4 (161.93) 39-3/4 (100.97) 800 (362.87) 33 404025736-3/4 (93.35) 63-3/4 (161.93) 39-3/4 (100.97) 800 (362.87) 18.5 4040258

Air-Cooled Scroll Condensing Unit

Page 17: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 7

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies continued

Air-Cooled, Semi-Hermetic Recipricating

• Suction and discharge vibration eliminators

• Spring mounting• Fixed High and adjustable low

pressure switches• Sentronic oil failure switch• Manual pump-down switch• Crankcase heater and head

pressure valve• Sight glass and permanent

liquid line filter• Vertical receiver needs less

refrigerant for liquid seal• Base valve and high and low

pressure taps on outside of unit• Easy to view sight glass location• Dual isolation valves on receiver• Fan cycling• Low ambient kit (heated and

insulated receiver with low pressure cut-out time delay)

• Dual pressure control• Adjustable high pressure control

with manual reset• Compressor fusing• Mounted liquid line solenoid

valve• Suction accumulator• NEMA contactors• All units are R-404a and

R-507 compatible

O R D E R I N F O R M A T I O NAir-Cooled, Semi-Hermetic Recipricating7.5 Hp, 208/230V, 3Ph, 50/60 Hz 40401637.5 Hp, 380/460V, 3Ph, 50/60 Hz 404009110 Hp, 208/230V, 3Ph, 50/60 Hz 404017610 Hp, 380/460V, 3Ph, 50/60 Hz 404017715 Hp, 208/230V, 3Ph, 50/60 Hz 404017815 Hp, 380/460V, 3Ph, 50/60 Hz 404017930Hp, 208/230V, 3Ph, 50/60 Hz 404018030Hp, 380/460V, 3Ph, 50/60 Hz 404018150Hp, 208-230V,3Ph, 50/60 Hz 50Hp, 400-460V,3Ph, 50/60 Hz

DIMENSIONS INCHES (CM)APPROX. NET WT.

LBS. (KG)PART

NUMBERHEIGHT WIDTH DEPTH RLA

36-3/4 (93.35) 63-3/4 (161.93) 39-1/4 (99.70) 1,020 (462.66) 17.9 404009136-3/4 (93.35) 63-3/4 (161.93) 39-1/4 (99.70) 1,020 (462.66) 36.8 404016336-3/4 (93.35) 63-3/4 (161.93) 39-1/4 (99.70) 1,045 (474.00) 39.1 404017636-3/4 (93.35) 63-3/4 (161.93) 39-1/4 (99.70) 1,045 (474.00) 17.9 4040177144 (365.76) 44.5 (113.03) 55.6 (141.22) 1,580 (716.68) 59.6 4040178144 (365.76) 44.5 (113.03) 55.6 (141.22) 1,580 (716.68) 29 4040179144 (365.76) 44.5 (113.03) 55.6 (141.22) 3,160 (1433.35) 59.6 4040180144 (365.76) 44.5 (113.03) 55.6 (141.22) 3,160 (1433.35) 29 4040181

Air-Cooled Semi-Hermetic Condensing Unit

Page 18: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 8

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Electonic Expansion Valves

Valve

• Electronic expansion valves have proportional modulation

• Excellent technical and functional characteristics • Allow efficient control for refrigera-

tion and consistent energy saving performances.

• The flow of refrigerant is modulated by a nozzle coupled to a torpedo-shaped aperture, measuring more than 15mm long, over a wide operating range.

• The internal mechanism is fitted on a calibrated spring with ball bearings and guarantees a stable and reliable regulation reducing the risks of failures.

Controller Assembly

• Enhanced with advanced functions

• New user interface makes it easier to use and configure

• Superheat control with auxiliary high pressure, low pressure and low superheat protection

• Battery module• Self-adaptive algorithm• Connection diagram

visible on the display• LEDs for monitoring

the main parameters

O R D E R I N F O R M A T I O NElectronic Expansion ValvesKit, Valve, EEV, 3-6 Hp, 1 Compressor, 1 Evaporator 4040214Kit, Valve, EEV, 7.5 Hp, 1 Compressor, 1 Evaporator 4040215Kit, Valve, EEV, 4 Hp, 1 Compressor, 2 Evaporators 4040216Kit, Valve, EEV, 5 Hp, 1 Compressor, 2 Evaporators 4040217Kit, Valve, EEV, 6 Hp, 1 Compressor, 2 Evaporators 4040218Kit, Valve, EEV, 7.5 Hp, 1 Compressor, 2 Evaporators 4040219Kit, Valve, EEV, 15 Hp, 1 Compressor, 2 Evaporators 4040240

O R D E R I N F O R M A T I O NElectronic Expansion Valve DriversController Assy, EEV, 1 Circuit 4040184Controller Assy, EEV, 2 Circuit 4040191Controller Assy, EEV, 4 Circuit 4040192Controller Assy, EEV, 6 Circuit 4040193

Electronic Expansion Valve

EEV Controller

Page 19: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 1 9

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Refrigeration Ordering Guide

Water-Cooled Condensing Unit Assemblies50Hz with R-404a, ONE Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR)

50 HZ W/R-404aCONDENSING

WATER EEV EEV CONTROLLER CONDENSING UNITAT 50°F (10°C)

AT 85°F (29°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

600 1 51,500 44,100 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 380V, 3Ph

800 1 67,000 56,500 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

1000 2 79,000 65,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 380V, 3Ph

1250 2 79,000 65,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 380V, 3Ph

1500 2 95,500 79,500 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

2000 2 95,500 79,500 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

2500 2 95,500 79,500 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

3000 2 95,500 79,500 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

Page 20: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 0

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Water-Cooled Condensing Unit Assemblies50 Hz with R-404a, TWO Condensing Units

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR)

50 HZ W/R-404aCONDENSING

WATER EEV EEV CONTROLLER CONDENSING UNITAT 50°F (10°C)

AT 85°F (29°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

1000 2 51,500 44,100 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 380V, 3Ph

1250 2 51,500 44,100 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 380V, 3Ph

1500 2 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

2000 2 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

2500 2 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

3000 2 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

4000 4 79,000 65,500 4040217

Kit, Valve,EEV, 5 Hp

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 380V, 3Ph

5000 4 79,000 65,500 4040217

Kit, Valve,EEV, 5 Hp

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 380V, 3Ph

6000 4 95,500 79,500 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

7000 4 95,500 79,500 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

8000 4 95,500 79,500 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 380V, 3Ph

Page 21: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 1

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Water-Cooled Condensing Unit Assemblies50 Hz with R-404a, FOUR Condensing Units

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR)

50 HZ W/R-404aCONDENSING

WATER EEV EEV CONTROLLER CONDENSING UNITAT 50°F (10°C)

AT 85°F (29°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

4000 4 44,100 51,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 380V, 3Ph

5000 4 44,100 51,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 380V, 3Ph

6000 4 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

7000 4 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

8000 4 67,000 56,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 380V, 3Ph

Page 22: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 2

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Air-Cooled Condensing Unit Assemblies50 Hz with R-404a, ONE Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS

(BTU/HR) 50 HZ WTIH R-404a EEV EEV CONTROLLER CONDENSING UNIT

AT 95°F (35°C)PART

NO. DESCRIPTIONPART

NO. DESC.PART

NO. DESCRIPTION

600 1 38,800 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

800 1 49,500 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

1000 2 57,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

1250 2 57,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

1500 2 75,200 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

2000 2 75,200 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

2500 2 95,000 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040163 7.5 Hp, 208/230V, 3Ph

4040091 7.5 Hp, 380V, 3Ph

3000 2 115,000 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040176 10 Hp, 208/230V, 3Ph

4040177 10 Hp, 380V, 3Ph

Page 23: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 3

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Air-Cooled Condensing Unit Assemblies50 Hz with R-404a, TWO Condensing Units

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS

(BTU/HR) 50 HZ WITH R-404a EEV EEV CONTROLLER CONDENSING UNIT

AT 95°F (35°C)PART

NO. DESCRIPTIONPART

NO. DESC.PART

NO. DESCRIPTION

1000 2 38,800 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

1250 2 38,800 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

1500 2 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

2000 2 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

2500 2 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

3000 2 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

4000 4 57,500 4040217

Kit, Valve,EEV, 5 Hp

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

5000 4 57,500 4040217

Kit, Valve,EEV, 5 Hp

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

6000 4 75,200 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

7000 4 75,200 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

8000 4 95,000 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

40401637.5 Hp, 208/230V,

3Ph

4040091 7.5 Hp, 380V, 3Ph

Page 24: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 4

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Air-Cooled Condensing Unit Assemblies50 Hz w/R-404a, FOUR Condensing Units

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS

(BTU/HR) 50 HZ WITH R-404a EEV EEV CONTROLLER CONDENSING UNIT

AT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

4000 4 38,800 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

5000 4 38,800 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

6000 4 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

7000 4 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

8000 4 49,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

Page 25: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 5

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Split System, Air-Cooled Condenser with Compressor Module 50 Hz w/R-404a, ONE Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 50 HZ W/

R-404a EEVEEV

CNTRLR.COMPRESSOR

MODULECONDENSING

MODULEAT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

PART NO. DESCRIPTION

600 1 38,800

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly,

1 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

800 1 49,500

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly,

1 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

1000 2 57,500

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly,

1 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040174 6 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

1250 2 57,500

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 380V, 3Ph 4040206 6 Hp, 380V, 3Ph

1500 2 75,200

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040211 7.5 Hp, 380V, 3Ph

2000 2 75,200

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040211 7.5 Hp, 380V, 3Ph

2500 2 75,200

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040211 7.5 Hp, 380V, 3Ph

3000 2 75,200

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040211 7.5 Hp, 380V, 3Ph

Page 26: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 6

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Split System, Air-Cooled Condenser with Compressor Module 50 Hz w/R-404a, TWO Units

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 50 HZ W/ R-404a EEV

EEV CNTRLR.

COMPRESSOR MODULE

CONDENSING MODULE

AT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

PART NO. DESCRIPTION

1000 2 38,800

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

1250 2 38,800

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

1500 2 49,500

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

2000 2 49,500

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

2500 2 49,500

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

3000 2 49,500

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

4000 4 57,500

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 380V, 3Ph 4040206 6 Hp, 380V, 3Ph

5000 4 57,500

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 380V, 3Ph 4040206 6 Hp, 380V, 3Ph

6000 4 75,200

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040211 7.5 Hp, 380V, 3Ph

7000 4 75,200

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040206 6 Hp, 380V, 3Ph

8000 4 95,000

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 380V, 3Ph 4040211 7.5 Hp, 380V, 3Ph

Page 27: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 7

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Split System, Air-Cooled Condenser with Compressor Module 50 Hz w/R-404a, FOUR Units

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 50 HZ W/ R-404a EEV

EEV CNTRLR.

COMPRESSOR MODULE

CONDENSING MODULE

AT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

PART NO. DESCRIPTION

4000 4 38,800

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

5000 4 38,800

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

6000 4 49,500

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

7000 4 49,500

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

8000 4 49,500

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 380V, 3Ph 4040203 5 Hp, 380V, 3Ph

Page 28: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 8

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Water-Cooled Condensing Unit Assemblies60 Hz w/R-507, ONE Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR)

60 HZ W/R-507

EEV EEV CONTROLLER CONDENSING UNITCONDENSING

WATERAT 50°F (10°C)

AT 85°F (29°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

600 1 62,500 54,000 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

800 1 81,000 67,500 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 460V, 3Ph

1000 2 81,000 67,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 460V, 3Ph

1250 2 97,000 81,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 2 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 460V, 3Ph

1500 2 97,000 81,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 2 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 460V, 3Ph

2000 2 97,000 81,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 2 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 460V, 3Ph

2500 2 97,000 81,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 2 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 460V, 3Ph

3000 2 117,000 97,500 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 460V, 3Ph

Page 29: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 2 9

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Water-Cooled Condensing Unit Assemblies60 Hz w/R-507, TWO Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR)

60 HZ W/R-507

EEV EEV CONTROLLER CONDENSING UNITCONDENSING

WATERAT 50°F (10°C)

AT 85°F (29°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

1000 2 45,500 38,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040220 3 Hp, 208/230V, 1Ph

4040221 3 Hp, 208/230V, 3Ph

4040222 3 Hp, 460V, 3Ph

1250 2 45,500 38,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040220 3 Hp, 208/230V, 1Ph

4040221 3 Hp, 208/230V, 3Ph

4040222 3 Hp, 460V, 3Ph

1500 2 62,500 54,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

2000 2 62,500 54,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

2500 2 62,500 54,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

3000 2 62,500 54,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

4000 4 81,000 67,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 460V, 3Ph

5000 4 81,000 67,500 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 460V, 3Ph

6000 4 97,000 81,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 460V, 3Ph

7000 4 97,000 81,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040229 6 Hp, 208/230V, 3Ph

4040230 6 Hp, 460V, 3Ph

8000 4 117,000 97,500 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040191

Controller Assembly,

EEV, 2 Circuit

4040231 7.5 Hp, 208/230V, 3Ph

4040232 7.5 Hp, 460V, 3Ph

Page 30: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 0

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Water-Cooled Condensing Unit Assemblies60 Hz w/R-507, FOUR Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR)

60 HZ W/R-507

EEV EEV CONTROLLER CONDENSING UNITCONDENSING

WATERAT 50°F (10°C)

AT 85°F (29°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

4000 4 45,500 38,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040192

Controller Assembly,

EEV, 4 Circuit

4040220 3 Hp, 208/230V, 1Ph

4040221 3 Hp, 208/230V, 3Ph

4040222 3 Hp, 460V, 3Ph

5000 4 45,500 38,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040192

Controller Assembly,

EEV, 4 Circuit

4040220 3 Hp, 208/230V, 1Ph

4040221 3 Hp, 208/230V, 3Ph

4040222 3 Hp, 460V, 3Ph

6000 4 62,500 54,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040192

Controller Assembly,

EEV, 4 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

7000 4 62,500 54,000 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040192

Controller Assembly,

EEV, 4 Circuit

4040223 4 Hp, 208/230V, 1Ph

4040224 4 Hp, 208/230V, 3Ph

4040225 4 Hp, 460V, 3Ph

8000 4 81,000 67,500 4040214

Kit, Valve, EEV, 3-6 Hp,

1 Compressor, 1 Evaporator 4040192

Controller Assembly,

EEV, 4 Circuit

4040226 5 Hp, 208/230V, 1Ph

4040227 5 Hp, 208/230V, 3Ph

4040228 5 Hp, 460V, 3Ph

Page 31: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 1

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Air-Cooled Condensing Unit Assemblies60 Hz w/R-507, ONE Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 60 HZ W/

R-507 EEV EEV CONTROLLER CONDENSING UNITAT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

600 1 47,800 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 460V, 3Ph

800 1 59,000 4040214

Kit, Valve, EEV, 4 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 460V, 3Ph

1000 2 59,000 4040217

Kit, Valve, EEV, 5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 460V, 3Ph

1250 2 71,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040157 6 Hp, 208/230V, 3Ph

4040156 6 Hp, 460V, 3Ph

1500 2 71,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040157 6 Hp, 208/230V, 3Ph

4040156 6 Hp, 460V, 3Ph

2000 2 71,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 460V, 3Ph

2500 2 71,000 4040218

Kit, Valve, EEV, 6 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 460V, 3Ph

3000 2 117,000 4040219

Kit, Valve, EEV, 7.5 Hp,

1 Compressor, 1 Evaporator 4040184

Controller Assembly,

EEV, 1 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 460V, 3Ph

Page 32: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 2

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Air-Cooled Condensing Unit Assemblies60 Hz w/R-507, TWO Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 60 HZ W/

R-507 EEV EEV CONTROLLER CONDENSING UNITAT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

1000 2 59,000 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040166 3 Hp, 208/230V, 1Ph

4040165 3 Hp, 208/230V, 3Ph

4040164 3 Hp, 380V, 3Ph

1250 2 71,000 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040166 3 Hp, 208/230V, 1Ph

4040165 3 Hp, 208/230V, 3Ph

4040164 3 Hp, 380V, 3Ph

1500 2 62,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

2000 2 62,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

2500 2 62,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

3000 2 62,500 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040191

ControllerAssembly

EEV2 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

4000 4 81,000 4040217

Kit, Valve,EEV, 5 Hp

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

5000 4 81,000 4040217

Kit, Valve,EEV, 5 Hp

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

6000 4 97,000 4040218

Kit, Valve,EEV, 6 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

7000 4 97,000 4040218

Kit, Valve,EEV, 6 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 460V, 3Ph

8000 4 117,000 4040219

Kit, Valve,EEV, 7.5 Hp,

1 Compressor,2 Evaporators 4040191

ControllerAssembly

EEV2 Circuit

4040257 7.5 Hp, 208/230V, 3Ph

4040258 7.5 Hp, 380V, 3Ph

Page 33: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 3

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Air-Cooled Condensing Unit Assemblies60 Hz w/R-507, FOUR Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 60 HZ W/

R-507 EEV EEV CONTROLLER CONDENSING UNITAT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

4000 4 33,300 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040166 3 Hp, 208/230V, 1Ph

4040165 3 Hp, 208/230V, 3Ph

4040164 3 Hp, 380V, 3Ph

5000 4 33,300 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040166 3 Hp, 208/230V, 1Ph

4040165 3 Hp, 208/230V, 3Ph

4040164 3 Hp, 380V, 3Ph

6000 4 47,800 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

7000 4 47,800 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040152 4 Hp, 208/230V, 1Ph

4040151 4 Hp, 208/230V, 3Ph

4040150 4 Hp, 380V, 3Ph

8000 4 59,000 4040214

Kit, Valve,EEV, 3-6 Hp,

1 Compressor,1 Evaporator 4040192

ControllerAssembly

EEV4 Circuit

4040155 5 Hp, 208/230V, 1Ph

4040154 5 Hp, 208/230V, 3Ph

4040153 5 Hp, 380V, 3Ph

Page 34: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 4

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Split System, Air-Cooled Condenser with Compressor Module 60 Hz w/R-507, ONE Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 50 HZ W/ R-404a EEV

EEV CNTRLR.

COMPRESSOR MODULE

CONDENSING MODULE

AT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

PART NO. DESCRIPTION

600 1 47,800

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly,

1 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

800 1 59,000

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly,

1 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

1000 2 59,000

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly,

1 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

1250 2 71,000

4040218 Kit, Valve, 6 Hp, 1 Compressor,

1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 460V, 3Ph 4040206 6 Hp, 460V, 3Ph

1500 2 71,000

4040218 Kit, Valve, 6 Hp, 1 Compressor,

1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 460V, 3Ph 4040206 6 Hp, 460V, 3Ph

2000 2 71,000

4040218 Kit, Valve, 6 Hp, 1 Compressor,

1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 460V, 3Ph 4040206 6 Hp, 460V, 3Ph

2500 2 71,000

4040218 Kit, Valve, 6 Hp, 1 Compressor,

1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 460V, 3Ph 4040206 6 Hp, 460V, 3Ph

3000 2 91,500

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040184 Controller Assembly, 1 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 460V, 3Ph 4040211 7.5 Hp, 460V, 3Ph

Page 35: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 5

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Split System, Air-Cooled Condenser with Compressor Module 60 Hz w/R-507, TWO Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 50 HZ W/ R-404a EEV

EEV CNTRLR.

COMPRESSOR MODULE

CONDENSING MODULE

AT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

PART NO. DESCRIPTION

1000 2 41,600

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040167 3 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040183 3 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040182 3 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

1250 2 41,600

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040167 3 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040183 3 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040182 3 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

1500 2 41,600

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040167 3 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040183 3 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040182 3 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

2000 2 47,800

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

2500 2 47,800

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

3000 2 47,800

4040214 Kit, Valve, 4 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

4000 4 59,000

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

5000 4 59,000

4040217 Kit, Valve, 5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040171 5 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

6000 4 71,000

4040218 Kit, Valve, 6 Hp, 1 Compressor,

1 Evaporator

4040191 ControllerAssembly2 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 460V, 3Ph 4040206 6 Hp, 460V, 3Ph

7000 4 71,000

4040218 Kit, Valve, 6 Hp, 1 Compressor,

1 Evaporator

4040191 ControllerAssembly2 Circuit

4040175 6 Hp, 208/230V, 3Ph 4040207 6 Hp, 208/230V, 3Ph

4040174 6 Hp, 460V, 3Ph 4040206 6 Hp, 460V, 3Ph

8000 4 91,500

4040219 Kit, Valve, 7.5 Hp,

1 Compressor, 1 Evaporator

4040191 ControllerAssembly2 Circuit

4040208 7.5 Hp, 208/230V, 3Ph 4040210 7.5 Hp, 208/230V, 3Ph

4040209 7.5 Hp, 460V, 3Ph 4040211 7.5 Hp, 460V, 3Ph

Page 36: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 6

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Unit Assemblies

Split System, Air-Cooled Condenser with Compressor Module 60 Hz w/R-507, ONE Condensing Unit

TANK SIZE (GAL)

NO. OF PLATES

IN TANK

CAPACITY OF UNITS (BTU/HR) 50 HZ W/ R-404a EEV

EEV CNTRLR.

COMPRESSOR MODULE

CONDENSING MODULE

AT 95°F (35°C)

PART NO. DESCRIPTION

PART NO. DESC.

PART NO. DESCRIPTION

PART NO. DESCRIPTION

4000 4 41,600

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040167 3 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040183 3 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040182 3 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

5000 4 41,600

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040167 3 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040183 3 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040182 3 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

6000 4 47,800

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

7000 4 47,800

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040170 4 Hp, 208/230V, 1Ph 4040202 5 Hp, 208/230V, 1Ph

4040169 4 Hp, 208/230V, 3Ph 4040204 5 Hp, 208/230V, 3Ph

4040168 4 Hp, 460V, 3Ph 4040203 5 Hp, 460V, 3Ph

8000 4 59,000

4040214 Kit, Valve, 3-6 Hp,

1 Compressor, 1 Evaporator

4040192 Controller Assembly,

4 Circuit

4040173 5 Hp, 208/230V, 1Ph 4040205 8Hp, 208/230V, 1Ph

4040172 5 Hp, 208/230V, 3Ph 4040207 8Hp, 208/230V, 3Ph

4040171 5 Hp, 460V, 3Ph 4040206 8Hp, 460V, 3Ph

Page 37: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 7

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Compressor Accessories

Copeland Modular Pump-Down Kits Help maintain proper CIP wash water temperature in the milk cooler by effectively removing liquid refrigerant from the evaporator plates before the compressor shuts down.

Kit include:

• 230 volt solenoid valve mounted after the liquid line filter on the rear of the cooler

• An in-line check valve mounted in the discharge line of the compressor.

Four-Year Extended Compressor WarrantyThe external warranty is available to cover the second through fifth year of the motor compressor only. Read warranty for complete details. Available on all condensing units or replacement compressors.

Five-Year Extended Cooler WarrantyThe extended warranty is available on all new Glacier coolers shipped to North America. The optional warranty extends the original 5-year warranty to 10-years and protects the original purchaser against internal refrigeration leaks.

Copeland Modular Scroll Compressor Replacement Bodies Only:Use these replacement compressor bodies on Copeland Modular units, obsolete Carlyle Scroll compressor assemblies, and on 7.5 Hp. Tecumseh and Copeland hermetic reciprocating compressors.

O R D E R I N F O R M A T I O NPump Down Solenoid, Check Valve Kit,3, 4, 5 Hp 4024216

O R D E R I N F O R M A T I O NCopeland Scroll Compressor3 Hp, 208/230-1-60 40242314 Hp, 208/230-1-60 40242324 Hp, 208/230-3-60 40242335 Hp, 208/230-1-60 40242355 Hp, 208/230-3-60 40242365 Hp, 460-3-60 40242377.5 Hp, 208/230-3-60 40242387.5 Hp,460-3-60 402423910 Hp, 460-3-60 402424010 Hp, 208/230-3-60 4024241

O R D E R I N F O R M A T I O N4-Year Extended Warranty3 Hp Scroll 41000024 Hp Reciprocating or 4 Hp Scroll 41000035 Hp Reciprocating or 5 Hp Scroll 41000047.5 Hp Scroll 410000510 Hp Scroll 4100007

O R D E R I N F O R M A T I O N5-Year Extended WarrantyCooler, 5-Year Extended 4100010

4024216 - Pump Down Solenoid Kit

4024236 - 5 Hp, 208/230-3-60 Copeland

Scroll Compressor

Page 38: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 8

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Tubing and Accessories

Refrigeration ManifoldsFor use in converting a dual evaporator DKF cooler to a single evaporator. Both suction and liquid line manifolds should be ordered.

Refrigeration Tubing SetUsed to connect condensing units to coolers. Suction tube is insulated. Both tubes are soft copper, nitrogen charged with ends capped.

O R D E R I N F O R M A T I O NDKF Suction Manifold Solder Fitting Kit 4022903DKF Liquid Line Distributor 4015617

O R D E R I N F O R M A T I O N LINE SIZES LENGTH HP SIZES SUCTION/ LIQUID PART NO.

50’ 3, 4, 5 7/8” and 3/8” 4012932

4022903 - Suction Manifold Solder Fitting Kit

4015617 - Liquid Line Distributor

4012932 - Refrigeration Tubing Set

Page 39: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 3 9

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Tubing and Accessories

Discharge LineUsed to connect the hot gas discharge from a compressor to a Heat Recovery System or remote condenser. Both sizes are insulated, soft copper tubing, Nitrogen charged, with ends capped.

Milkline Position SwitchElectrically disconnects pipeline washer when switch is activated thereby preventing a milk loss due to operator error. Fits all pipeline washers

O R D E R I N F O R M A T I O NMilkline Position Switch 4017302

O R D E R I N F O R M A T I O NLENGTH OD SIZES USED ON PART NO.

50’ 5/8” 3 Hp - 5 Hp 401674330’ 3/4” 7.5 Hp 4016744

4016743 - Discharge Line

4017302 - Milkline Position Switch

Page 40: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 0

Cooling D e a l e r C a t a l o g

C o n d e n s i n g U n i t s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Cooler and Condenser Accessories

Temperature Chart RecorderAnderson circular temperature chart recorder, comes factory pre-set for 7-day chart rotation, read-out in °F, 50-foot pre-wired temperature sensor. Recorder comes in a waterproof enclosure, has a built-in LED tempera-ture display and an adjustable high-temperature alarm relay. Kit includes pack of 100 7-day, °F blank charts. The recorder is field adjustable for 24, 48, 72-hour or 7-day chart rotation, °F or °C temperature read-out.

Tri-Clamp Thermo-WellsStainless thermo-wells mount into tri-clamp 2”, 2-1/2” or 3” tees. These smooth bore thermo-wells are designed to accept 3/8” diameter temperature sensors from Anderson circular chart recorders and Glacier-Guards. Use heat transfer compound (PN 4016682) before inserting temperature sensors into thermo-well to improve heat transfer and instrument accuracy.

Chart Calibration–ReplacementReplace lost or damaged calibration charts. When ordering specify cooler size, serial number and units of measure (ie. pounds, liters, kg., stick increment scale; inches or centimeters). This is a special order; contact your Customer Service Representative.

O R D E R I N F O R M A T I O NChart Recorder (complete as indicated) 4024300100 charts, 7 day °F 4024301100 charts, 7 day °C 4024302100 charts, 3 day °F 40243035 replacement cartridge pens 4024305RTD sensor probe with 50 ft. lead 4024307

O R D E R I N F O R M A T I O NThermo-Well, smooth, 2” Tri-Clamp 4024327

O R D E R I N F O R M A T I O NReplacement Cooler Chart 4087660

4024300 - Chart Recorder

4024327 - Thermo-Well, smooth, 2” Tri-Clamp

4087660 - Replacement Cooler Chart

Page 41: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 1

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers for Europe

Glacier™ Tanks2000 to 24000 liters 4 milkings 4BII

• Tank with legs, manhole lid, ladder, spray head for cleaning, air vent, outlet valve, agitator.

• Front cabinet with Glacier™ controller, wash pump, water valves, 2 dosing pumps.

• T° probe, electric devices, wired, mounted, tested. • Dipstick and calibration chart with individual calibration.

Plastic foil packaging for shipping protection. • One or two condensing units.

DESCRIPTIONVOLUME

(LITERS)CONDENSING

UNITS (HP)TOTAL

HP PART NO.

Condensing units mounted on the tank: Glacier 2000 Unit 4M 2000 1 x 3 Hp 3 4040438Glacier 2500 Unit 4M 2500 1 x 3.5 Hp 3.5 4040439Glacier 3000 Unit 4M 3000 1 x 4 Hp 4 4040440Glacier 4000 Unit 4M 4000 1 x 5 Hp 5 4040441

Remote condensing unitsGlacier 5000 Unit 4M 5000 1 x 6.5 Hp 6.5 4040442Glacier 6000 Unit 4M 6000 1 x 8.5 Hp 8.5 4040443Glacier 8000 Unit 4M 8000 1 x 10 Hp 10 4040444Glacier 8000 Unit 4M 8000 2 x 5 Hp 11 4040445Glacier 10000 Unit 4M 10000 1 x 13 Hp 13 4040446Glacier 10000 Unit 4M 10000 2 x 6.5 Hp 13 4040447Glacier 12000 Unit 4M 12000 2 x 8.5 Hp 17 4040448Glacier 14000 Unit 4M 14000 2 x 10 Hp 20 4040449Glacier 16000 Unit 4M 16000 2 x 13 Hp 26 4040450Glacier 18000 Unit 4M 18000 2 x 13 Hp 26 4040451Glacier 20000 Unit 4M 20000 2 x 13 Hp 26 4040452Glacier 24000 Unit 4M 24000 2 x 15 Hp 30 4040453*Note: The outlet valve is mandatory and must be ordered separately. Please select the appropriate outlet valve on the “options” page.

Use the Following Chart to Order a Glacier™ Cooling Tanks Ordering Guide:

Page 42: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 2

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers for Europe

Glacier™ Tanks2000 to 24000 liters 2 milkings 2BII

• Tank with legs, manhole lid, ladder, spray head for cleaning, air vent, outlet valve, agitator.

• Front cabinet with Glacier™ controller, wash pump, water valves, 2 dosing pumps.

• T° probe, electric devices, wired, mounted, tested. • Dipstick and calibration chart with individual calibration.

Plastic foil packaging for shipping protection. • One or two condensing units.

DESCRIPTIONVOLUME

(LITERS)CONDENSING

UNITS (HP) TOTAL HP PART NO.

Condensing units mounted on the tank: Glacier 2000 Unit 2M 2000 1 x 5 Hp 5 4040454Glacier 2500 Unit 2M 2500 1 x 6.5 Hp 6.5 4040455Glacier 3000 Unit 2M 3000 1 x 8.5 Hp 8.5 4040456Glacier 4000 Unit 2M 4000 1 x 10 Hp 10 4040457Glacier 4000 Unit 2M 4000 2 x 5 Hp 10 4040458

Remote condensing unitsGlacier 5000 Unit 2M 5000 1 x 13 Hp 13 4040459Glacier 5000 Unit 2M 5000 2 x 6.5 Hp 13 4040460Glacier 6000 Unit 2M 6000 2 x 8.5 Hp 17 4040461Glacier 8000 Unit 2M 8000 2 x 10 Hp 20 4040462Glacier 10000 Unit 2M 10000 2 x 13 Hp 26 4040463Glacier 12000 Unit 2M 12000 2 x 15 Hp 30 4040464Glacier 14000 Unit 2M 14000

Assembly to be combined, tank + units with the chart

assembly precooling mandatory

Glacier 16000 Unit 2M 16000Glacier 18000 Unit 2M 18000Glacier 20000 Unit 2M 20000Glacier 24000 Unit 2M 24000*Note: The outlet valve is mandatory and must be ordered separately. Please select the appropriate outlet valve on the “options” page.

Use the Following Chart to Order a Glacier Cooling Tanks Ordering Guide:

Page 43: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 3

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers for Europe

Glacier™ Tanks2000 to 24000 liters without condensing unit

• Tank with legs, manhole lid, ladder, spray head for cleaning, air vent, outlet valve, agitator.

• Front cabinet with Glacier™ controller, wash pump, water valves, 2 dosing pumps.

• T° probe, electric devices, wired, mounted, tested. • Dipstick and calibration chart with individual calibration.

Plastic foil packaging for shipping protection.

DESCRIPTIONVOLUME

(LITERS) PART NO.

Without condensing units mounted on the tank: Glacier 2000 without Condensing Unit 2000 4040470Glacier 2500 without Condensing Unit 2500 4040471Glacier 3000 without Condensing Unit 3000 4040472Glacier 4000 without Condensing Unit 4000 4040473Glacier 5000 without Condensing Unit 5000 4040474Glacier 6000 without Condensing Unit 6000 4040475Glacier 8000 without Condensing Unit 8000 4040476Glacier 10000 without Condensing Unit 10000 4040477Glacier 12000 without Condensing Unit 12000 4040478Glacier 14000 without Condensing Unit 14000 4040479Glacier 16000 without Condensing Unit 16000 4040480Glacier 18000 without Condensing Unit 18000 4040481Glacier 20000 without Condensing Unit 20000 4040482Glacier 24000 without Condensing Unit 24000 4040483

*Note: The outlet valve is mandatory and must be ordered separately. Please select the appropriate outlet valve on the “options” page.

Use the Following Chart to Order a Glacier Cooling Tanks Ordering Guide:

Page 44: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 4

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Coolers Options

3rd Dosing Pump for Detergent

Extra Heater for Washing

Washable Outlet Valves

Special Outlet Valves

Robot OptionsConsisting of:

• 1 pneumatic S/S two ways valve diameter DIN 50 or SMS 51.

• 1 electric board mounted in the cabinet controller.

• Suitable coupling between valve and wash pump in the Glacier controller cabinet.

Electronic Calibration • Linked with the individual calibration. • Milk tank volume displayed on digital screen.

O R D E R I N F O R M A T I O N3rd Dosing Pump for DetergentExtra Dosing Pump 4040547

O R D E R I N F O R M A T I O NExtra Heater for Washing Extra Heater 9KW 4040548

O R D E R I N F O R M A T I O NOutlet Valves DN76-SMS 4040551DN76-DN63 SMS 4040552D76 RED DN63 SMS 4040553D76 RED DN51 SMS 4040554DN76-DN76 F RJT 4040555DN76-DN63 F RJT 4040556D76 RED DN63 RJT 4040557D76 RED DN51 RJT 4040558

O R D E R I N F O R M A T I O NWashable Outlet Valves D.76-DIN 50 4040537D.76-SMS 51 4040538D.76-SMS 63 4040559D.76-RJT 63 4040560D.76-RJT 51 4040561

O R D E R I N F O R M A T I O NPack options Robot DN 50 4040442Robot SMS 51 4040443

O R D E R I N F O R M A T I O NElectronic Calibration 4040549

Page 45: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 5

CoolingD e a l e r C a t a l o g

C o o l i n g T a n k s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers for Europe

Open Top Vertical Tanks (Including condensing unit mounted R404A)

• Without butterfly valve

DESCRIPTIONVOLUME

(LITERS) TOTAL HP PART NO.

4 Milkings 4BIIGlacier Vert 4M Mono 220V 200 .33 4040491Glacier Vert 4M Mono 220V 300 0.5 4040492Glacier Vert 4M Mono 220V 430 0.5 4040493Glacier Vert 4M Mono 220V 550 1.0 4040494Glacier Vert 4M Mono 220V 650 1.2 4040495Glacier Vert 4M Tri 380V 650 1.2 4040496Glacier Vert 4M Mono 220V 800 1.2 4040497Glacier Vert 4M Tri 380V 800 1.2 4040498Glacier Vert 4M Mono 220V 1000 2.0 4040499Glacier Vert 4M Tri 380V 1000 2.0 4040500Glacier Vert 4M Mono 220V 1200 2.0 4040501Glacier Vert 4M Tri 380V 1200 2.0 4040502Glacier Vert 4M Tri 380V 1390 2.3 4040503Glacier Vert 4M Tri 380V 1600 2.3 4040504Glacier Vert 4M Tri 380V 1880 3.0 4040505

2 Milkings 2BIIGlacier Vert 2M Mono 220V 100 .33 4040506Glacier Vert 2M Mono 220V 200 0.5 4040507Glacier Vert 2M Mono 220V 300 1.0 4040508Glacier Vert 2M Mono 220V 430 1.2 4040509Glacier Vert 2M Tri 380V 430 1.5 4040510Glacier Vert 2M Mono 220V 550 1.5 4040511Glacier Vert 2M Tri 380V 550 1.5 4040512Glacier Vert 2M Mono 220V 650 2.0 4040513Glacier Vert 2M Tri 380V 650 2.0 4040514Glacier Vert 2M Mono 220V 800 2.3 4040515Glacier Vert 2M Tri 380V 800 2.3 4040516Glacier Vert 2M Mono 220V 1000 3.0 4040517Glacier Vert 2M Tri 380V 1000 3.0 4040518Glacier Vert 2M Tri 380V 1200 3.5 4040519Glacier Vert 2M Tri 380V 1390 4.0 4040520Glacier Vert 2M Tri 380V 1600 4.0 4040521Glacier Vert 2M Tri 380V 1880 5.0 4040522

Outlet ValveOutlet Valve G1 G4 SMS 51 na na 4040541Outlet Valve G1 G4 DIN 50 na na 4040542

Use the Following Chart to Order a Glacier Open Top Vertical Tanks:

Page 46: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 6

Cooling D e a l e r C a t a l o g

C o o l i n g T a n k s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Glacier™ Milk Coolers for Europe

Open Top Vertical Tanks With washer and controller Glacier™ (incl. Outlet valve and unit R404A)

DESCRIPTIONVOLUME

(LITERS) TOTAL HP PART NO.

4 Milkings 4BIIGlacier Vert Washer 4M 1000 2.0 4040523Glacier Vert Washer 4M 1200 2.0 4040524Glacier Vert Washer 4M 1390 2.3 4040525Glacier Vert Washer 4M 1600 2.3 4040526Glacier Vert Washer 4M 1880 3.0 4040527Glacier Vert Washer 4M 2300 3.5 4040528Glacier Vert Washer 4M 2600 3.5 4040529

2 Milkings 2BIIGlacier Vert Washer 2M 1000 3.0 4040530Glacier Vert Washer 2M 1200 3.5 4040531Glacier Vert Washer 2M 1390 4.0 4040532Glacier Vert Washer 2M 1600 4.0 4040533Glacier Vert Washer 2M 1880 5.0 4040534Glacier Vert Washer 2M 2300 6.5 4040535Glacier Vert Washer 2M 2600 6.5 4040536

Use the Following Chart to Order a Glacier Open Top Vertical Tanks:

Page 47: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 7

CoolingD e a l e r C a t a l o g

C o n d e n s i n g U n i t s - E U

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Condensing Units

Condensing Units 3x400V, 50 Hz, R-404A with electric boxConsists of:

• Condenser• Frame• Ventilators• Service valve• Double pressostat• Compressor• Gas receiver• Gas R404A• Expansion valve• Circuit breakers• Electric box• Sight glass

Remote Condensing Units • This assembly includes all components

required for a remote condensing unit.• The condensing unit comes assembled,

wired and charged with refrigerant gas. • Copper tube for gas connection as

dealer supply.• Four types possible condensing units:

Maneurop, scroll, l’Unité and 1/2 hermetic.

Note: Gas receiver always included for all sizes.

O R D E R I N F O R M A T I O NManueropMTZ 36 Compact, 3 Hp 4040484MTZ 40 Compact, 3.5 Hp 4040485MTZ 50 Compact, 4 Hp 4040486MTZ 64 Compact, 5 Hp 4040487MTZ 80 Compact, 6.5 Hp 4040488

Scroll ZB58 Compact, 8 Hp 4040489ZB76 Compact, 10 Hp 4040490ZB95 Compact, 13 Hp 4040550

O R D E R I N F O R M A T I O NManueropMTZ 36 Remote, 3 Hp 4040360MTZ 40 Remote, 3.5 Hp 4040361MTZ 50 Remote, 4 Hp 4040362MTZ 64 Remote, 5 Hp 4040363MTZ 80 Remote, 6.5 Hp 4040364

Scroll ZB58 Remote, 8 Hp 4040366ZB76 Remote, 10 Hp 4040367ZB95 Remote, 13 Hp 4040368

Unite2 X TFH 4540 Z Remote, 2X3 Hp 40403692 X TAG 4553 Z Remote, 2 X 4, 5 Hp 40403702 X TAG 4573 Z Remote, 2 X 6, 5 Hp 4040371

SemiSEMI H. Hp 15X2 Remote, 2 X 15 Hp 4040372SEMI H. Hp 20X2 Remote, 2 X 20 Hp 4040373

4040484 - Condensing unit mounted on tank

4040360 - Remote condensing unit

Page 48: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 8

Cooling D e a l e r C a t a l o g

P r e - C o o l i n g

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Coolers

BouMatic® Single Coolant Plate Heat ExchangersThe plate heat exchanger (Plate Cooler) uses well water and/or chilled water to pre-cool milk before it enters the bulk tank. Pre-cooling milk can save on cooling energy costs and can help maintain milk quality. All Plate Coolers are C.I.P. ready.

Features Include:

• SS construction• Clip-on gaskets• Internal flow pattern ensures maximum heat

transfer and low pressure drop• Use for partial pre-cooling or 100% instant cooling• Designed for milking systems with as few as 4 units to more than 100 units

Model Designation: example N35SCO.5Model – N

Number of plates – 35

Number of coolants single or dual – SC

Frame size – 0.5

N77SC4 - Floor Mount

N35SC0.5 - Wall Mount

Wall Mount Bracket

Page 49: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 4 9

CoolingD e a l e r C a t a l o g

P r e - C o o l i n g

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Coolers

Single Pass Single Coolant

N-Series Plate Cooler Performance Data

Dual Pass Single Coolant

N-Series Plate Cooler Performance Data

COOLANT TEMPERATURE

MILK PUMP SIZE

COOLANT TO MILK FLOW RATIOWEIGHT

LBS. (KG)

CONNECTION

M (C)N-SERIES

NO.1:1 2:1 3:1

DEGREE REDUCTION OF MILK TEMPERATURE

50ºF / 10ºC Rated for .5 Hp (.4 kW) - 2 Hp (1.5 kW)

19/10.7 25/13.6 27/14.8142 lbs. (65 Kg) 1.5 1NPT N35SCO.5

60ºF / 15.6ºC 15/8.5 19/10.8 21/11.770ºF / 21.1ºC 11/6.2 14/8 16/8.6

COOLANT TEMPERATURE

MILK PUMP SIZE

COOLANT TO MILK FLOW RATIOWEIGHT

LBS. (KG)

CONNECTION

M (C)N-SERIES

NO.1:1 2:1 3:1

DEGREE REDUCTION OF MILK TEMPERATURE

50ºF / 10ºC Rated for .5 Hp (.4 kW) - 1 Hp (.75 kW)

27/14.8 33/18.6 36/20153 lbs. (70 Kg) 1.5 (1 NPT) N53SCO.5

60ºF / 15.6ºC 21/11.8 27/14.7 29/15.970ºF / 21.1ºC 16/8.7 20/10.8 21/11.7Based on 8gpm (30.3 L/min.) constant milk flow.

50ºF / 10ºC Rated for .5 Hp (.4 kW) - 1 Hp (.75 kW)

31/17 39/21.5 41/23331 lbs.

(150 Kg) 2 (2) N37SC160ºF / 15.6ºC 24/13.4 31/17 33/18.270ºF / 21.1ºC 18/10 23/12.5 24/13.4Based on 5gpm (19 L/min.) constant milk flow.

50ºF / 10ºC Rated for 1 Hp (.75 kW) -

2 Hp (1.5 kW)

31/17.2 39/21.5 41/23441 lbs.

(200 Kg) 2 (2) N81SC160ºF / 15.6ºC 25/13.6 31/17 33/18.270ºF / 21.1ºC 18/10 23/12.5 24/13.4Based on 15gpm (57 L/min.) constant milk flow.

50ºF / 10ºC Rated for 1 Hp (.75 kW) -

3 Hp (2.2 kW)

35/19.7 44/24.4 46/25.41324 lbs. (602 Kg) NA N53SC3

60ºF / 15.6ºC 28/15.6 35/19.3 36/20.170ºF / 21.1ºC 21/11.5 26/14.2 28/14.8Based on 15gpm (57 L/min.) constant milk flow.

50ºF / 10ºC Rated for 7.5 Hp (5.6 kW)

or Larger

32/17.8 40/22 42/23.51435 lbs. (652 Kg) NA N77SC4

60ºF / 15.6ºC 25/14.1 31/17.4 33/18.670ºF / 21.1ºC 19/10.4 23/12.8 25/13.7Based on 100gpm (378 L/min.) constant milk flow.

O R D E R I N F O R M A T I O NN35SC0.5 4025981

O R D E R I N F O R M A T I O NN53SC0.5 4025982N37SC1 4025751N81SC1 4025752N53SC3 4025753N77SC4 4025754

Based on 8gpm (30.3 L/min.) constant milk flow.

Well water in

Well water out

Milk out

Milk in

Chilled water out

Chilled water in

3-Pass Dual Coolant

Dual Pass Single Coolant

Coolant out Coolant in

Milk inMilk out

Single Pass Single Coolant

Coolant in

Coolant out

Milk out

Milk in

Well water in

Well water out

Milk out

Milk in

Chilled water out

Chilled water in

3-Pass Dual Coolant

Dual Pass Single Coolant

Coolant out Coolant in

Milk inMilk out

Single Pass Single Coolant

Coolant in

Coolant out

Milk out

Milk in

N35SC0.5 - Single pass single coolant

N53SC0.5, N37SC1, N81SC1, N53SC3, N77SC4 - Dual pass single coolant

Page 50: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 0

Cooling D e a l e r C a t a l o g

P r e - C o o l i n g

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Coolers

Dual Coolant Plate Coolers3 - Pass Dual Coolant

Dual Pass Water Dual Pass Glycol

COOLANT TEMPERATURE

MILK PUMP SIZE

COOLANT 1 TO MILK FLOW RATIOWEIGHT

LBS. (KG)

CONNECTION

M W GN-SERIES

NO.1:1 2:1 3:1

DEGREE REDUCTION OF MILK TEMPERATURE

50ºF / 10ºC Rated for 1 Hp (.75 kW) -

3 Hp (2.2 kW)

28/15.6 36/19.8 38/21.31479 lbs. (672 Kg) NA N64DC3

60ºF / 15.6ºC 22/12.3 28/15.6 30/16.770ºF / 21.1ºC 16/9.1 21/11.5 22/12.4Based on 20gpm (70 L/min.) constant milk flow.

50ºF / 10ºC Rated for 1 Hp (.75 kW) -

3 Hp (2.2 kW)

28/15.7 36/19.9 39/21.41655 lbs. (752 Kg) NA N100DC3

60ºF / 15.6ºC 22/12.4 28/15.7 31/16.970ºF / 21.1ºC 16/9.1 21/11.6 23/12.5Based on 30gpm (114 L/min.) constant milk flow.

50ºF / 10ºC Rated for 7.5 Hp (5.6 kW)

or Larger

23/13 29/16 31/17.42097 lbs. (953 Kg) NA N98DC4

60ºF / 15.6ºC 19/10.3 23/12.7 25/13.870ºF / 21.1ºC 13/7.6 17/9.3 18/10.2Based on 100gpm (378 L/min.) constant milk flow.

O R D E R I N F O R M A T I O NN64DC3 4025755N100DC3 4025756N98DC4 4025757

O R D E R I N F O R M A T I O NQ106DC3 4040893

Water in

Coolant in

Coolant outMilk inMilk out

Water out

3-Pass Dual Pass Coolant

COOLANT TEMPERATURE

MILK PUMP SIZE

COOLANT 1 TO MILK FLOW RATIOWEIGHT

LBS. (KG)

CONNECTION

M W GQ-SERIES

NO.1:1 2:1 3:1

DEGREE REDUCTION OF MILK TEMPERATURE

50ºF / 10ºC Rated for 1 Hp (.75 kW) -

3 Hp (2.2 kW)

35/19.7 44/24.4 46/25.41655 lbs. (751 Kg) NA Q106DC3

60ºF / 15.6ºC 28/15.6 35/19.3 36/20.170ºF / 21.1ºC 21/11.5 26/14.2 28/14.8Based on 15gpm (57 L/min.) constant milk flow.

Page 51: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 1

CoolingD e a l e r C a t a l o g

P r e - C o o l i n g

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Coolers

Plate Cooler Dimensions

MODEL A (IN.) A (mm) B (IN.) B (mm) C (IN.) C (mm) D (IN.) D (mm) E (IN.) E (mm) F (IN.) F (mm)

N35SC0.5 8.66 220 20.47 520 15.75 400 2.76 70 17.72 450 2.76 70N53SC0.5 8.66 220 20.47 520 17.72 450 2.76 70 2.76 70 2.76 70N37SC1 11.02 280 31.30 795 32.48 825 6.14 156 6.14 156 3.86 98N81SC1 11.02 280 31.30 795 32.48 825 6.14 156 6.14 156 3.86 98N53SC3 17.52 445 61.30 1557 37.40 950 12.76 324 12.76 324 8.86 225N77SC4 21.73 552 62.20 1580 46.06 1170 14.69 373 14.69 373 11.22 285N64DC3 17.52 445 61.30 1557 49.21 1250 12.76 324 55.43 1408 8.86 225N100DC3 17.52 445 61.30 1557 49.21 1250 12.76 324 55.43 1408 8.86 225N98DC4 21.73 552 62.20 1580 51.57 1310 14.69 373 56.02 1423 11.22 285Q106DC3 17.52 445 61.30 1557 45.37 1160 12.76 324 - - 8.88 225

Page 52: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 2

Cooling D e a l e r C a t a l o g

P r e - C o o l i n g

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Coolers Accessories

Eccentric and Concentric Tri-Clamp Reducing FittingsFor use on milk and coolant connections on the in.R in. plate cooler

Tri-Clamp to NPT adapterStainless 2 in. tri-clamp to 2 in. NPT adapter. Use to join chiller water connections to tri-clamp fittings on large plate coolers.

Dial Thermometer3 in. diameter Dial Thermometer accurately displays temperature in Fahrenheit from 0° to 220° and Celcius from -10° to 100°. Thermometer mounts in 1/2 in. F-NPT fitting, or use with stainless steel thermo-well for sanitary milk line applications.

8500569 - Eccentric reducer, 3 in. x 2 in.

8500350 - Concentric reducer, 3 in. x 2 in.

O R D E R I N F O R M A T I O N5 in. overall lengthEccentric reducer3 in. x 2 in. 8500569Concentric reducer3 in. x 2 in. 8500350

3 in. overall length Concentric reducer3 in. x 2.5 in. 8500389

O R D E R I N F O R M A T I O NTri-Clamp Adapter2 in. tri-clamp to NPT, stainless 8507941

O R D E R I N F O R M A T I O NDial Thermometer1/2 in. NPT 4023712

8507941 - Adapter, 2 in.

4023712 - Dial Thermometer

Page 53: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 3

CoolingD e a l e r C a t a l o g

P r e - C o o l i n g

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Cooler Accessories

Thermo-Well, Dial ThermometerAllows sanitary in-line installation of a Dial Thermometer into a milk line. Thermo-Well fits a standard 2 in. tri-clamp ferrule.

Thermo-Well, Temperature ProbeAllows in-line installation of a temperature control thermocouple into a water or coolant line. Brass Thermo-Well screws into a 3/4 in. F-NPT pipe fitting, and is designed to accept the temperature probes used on the Honeywell temperature controls.

Tri-Clamp Thermo-WellStainless thermo-well mount into tri-clamp 2 in. tees. This smooth bore thermo-well is designed to accept 3/8 in. diameter temperature sen-sors from Anderson circular chart recorders and Glacier-Guards. Use heat transfer compound (PN4016682) before inserting temperature sen-sor into thermo-well to improve heat transfer and instrument accuracy.

O R D E R I N F O R M A T I O NThermo-WellTri-Clamp, Dial Thermometer 4023713

O R D E R I N F O R M A T I O NThermo-WellTemperature Probe 4021912

O R D E R I N F O R M A T I O NThermo-WellSmooth, 2 in. Tri-Clamp 4024327

8507941 - Adapter, 2 in.

4021912 - Temperature Probe Thermo-Well

4024327 - Thermo-Well, smooth, 2 in. Tri-Clamp

Page 54: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 4

Cooling D e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Chiller Controls

ChillGuard™

Dairy Chiller Control • Engineered specifically for dairy cooling

equipment• Staged control of up to six compressors

(on/off)• Equalizes compressor run time• Controls glycol pump (on/off)• Equalizes run time of glycol pumps • Manages the well water pump and

well water valve (on during milk mode/off during wash mode)

• Service/Manual mode (single circuit systems)

• Alarm controls with data logger to view what caused an alarm and when it occured

4040688 - ChillGuard™ Dairy Chiller Control

O R D E R I N F O R M A T I O NDairy Chiller Control ChillGuard™ 4040688Switch, CurrentSplit-Core* 3561351* 1 switch required for each com-pressor and pump.

Page 55: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 5

CoolingD e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

GlacierChill™ Modular Brazed Plate Chiller

• �Increased�profitability by lowering operating costs.

• Peace of mind with BouMatic’s™ proprietary milk cooling protection system.

• The right choice for your dairy whether you are building a new parlor, replacing a worn-out system or upgrading from a falling film chiller or cooler tank.

A Quick Return on Your Investment

Save Money TODAYSave from $7,000 on your electric bill annually compared to falling film chillers.*�Based�on�156,000�lbs.�daily�milk�production,�$0.1206/KWh�electric�rates�and�falling�film�chiller�with�standard�scroll� compressors.

Save Money TOMORROWThe modular GlacierChill™ design expands with your dairy. Simply add GlacierChill modules as your

milk production increases.

Lower Energy CostsEngineered with your bottom line in mind, the exclusive design reduces operating costs, extends

compressor service life and provides protection for your valuable milk production. Whether building

new or replacing and aging cooling system, increase your profits and lower your milk cooling costs

with GlacierChill Modular Chiller from BouMatic.

• Up to 14% cost reduction due to the innovative expansion valve design

• Superior heat transfer performance from brazed plate evaporator vs. other

heat transfer technologies

• Gain�up�to�30%�efficiency through the use of digital compressors vs. standard

reciprocating technology

• Reduce Repair Time and Expense with the proprietary history tracker and

alarm status

Page 56: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 6

Cooling D e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

GlacierChill™ Modular Brazed Plate Chiller

GlacierChill™ Glycol Modules

• One glycol module required per chiller system.

GlacierChill™ Compressor Modules Remote Air-Cooled

• Use up to three compressor modules to build your cooling system.

GlacierChill™ Air-Cooled Condensers

• Use one condenser per compressor module.

O R D E R I N F O R M A T I O NCompressor Modules10 Hp, 208/230V, 3Ph 404098210 Hp, 460V, 3Ph 404097215 Hp, 208/230V, 3Ph 404098315 Hp, 460V, 3Ph 4040871

O R D E R I N F O R M A T I O NRemote Air-Cooled Condensers10 Hp, 208/230V, 3Ph 404098410 Hp, 460V, 3Ph 404035915 Hp, 208/230V, 3Ph 404098515 Hp, 460V, 3Ph 4040260

O R D E R I N F O R M A T I O NGlycol ModulesUSE WITH 10 AND 15 HP COMPRESSOR MODULES

5 Hp pumps, 208/230V, 3Ph 40409815 Hp pumps, 460V, 3Ph 4040825

4040985 - 15 Hp Remote Air-Cooled Condenser

4040983 - 15 Hp Compressor Module

4040825 - 10 and 15 Hp Glycol Module

Page 57: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 7

CoolingD e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Falling Film Chillers

Dari-Kool® Falling Film Chillers

Chillers supply a continuous flow of chilled water to Dari-Kool plate coolers. Provides “instant” cooling of milk before it

enters the bulk tank to help maintain the highest milk quality. Dari-Kool falling film chillers are available in 2 to 6-plate

configurations using the 6-plate cabinet, and in 6 to 12-plate configurations using the 12-plate cabinet. All 6-plate cabinets

are fitted with a 6-plate water distribution trough, and 12-plate cabinets are fitted with two 6-plate troughs, to make

adding additional plates easy and economical.

• Reservoir capacity: 140 gal. - 6-plate cabinet (198 gal. max.) 280 gal. - 12-plate cabinet (379 gal. max.)

• For use with R-12, R-22, R-502, R-507 refrigerant

• Water flow rate - 35 GPM per plate

• Refrigerant capacity per plate - 5-Ton, 60,000 Btuh*

• Water inlet(s): 1 - 2”M NPT inlet on 6-plate chillers 2 - 2”M NPT inlets on 12-plate chillers

• Water outlet(s): 1 - 3”M NPT outlet on 6-plate chillers 2 - 3”M NPT outlet on 12-plate chillers

* Actual capacity may vary depending on operating temperature and flow rate.

Falling Film Chillers 6-plate�cabinets Shipping dimensions: 36” wide x 85” high x 81” long

Falling Film Chillers 12-plate�cabinets The 12-plate falling film chiller cabinet is fitted with two 3” outlets, which can be plumbed together for single coolant water pump applications, or used separately for applications using two coolant water pumps. Use the optional field-installed baffle divider plate to allow a 12-plate chiller cabinet to provide two coolant temperatures to dual coolant plate coolers, and maximize compressor capacities.

Shipping dimensions: 64” wide x 85” high x 81” long

O R D E R I N F O R M A T I O NFalling Film Chillers 6-plateDISCRIPTION SHIPPING WT. PART NO.

Chiller Assy., 2-plate 1,250 lbs 4019878Chiller Assy.,3-plate 1,350 lbs 4019879Chiller Assy., 4-plate 1,450 lbs 4019880Chiller Assy.,5-plate 1,550 lbs 4019881Chiller Assy., 6-plate 1,650 lbs 4019882

O R D E R I N F O R M A T I O NFalling Film Chillers 12-plateDISCRIPTION SHIPPING WT. PART NO.

Chiller Assy., 6-plate 2,650 lbs 4021830Chiller Assy.,8-plate 2,850 lbs 4021618Chiller Assy., 10-plate 3,050 lbs 4021619Chiller Assy.,12-plate 3,250 lbs 4021620

4021620 - Chiller Assy., 12-plate

4019882 - Chiller Assy., 6-plate

Page 58: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 8

Cooling D e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Plate Coolers/Chiller Accessories

Water Solenoid ValvesTo be used when well water coolant supply is shut-off with the milk pump to reduce well water usage through the plate cooler. 220/240 VAC.

Timer Delay (Delay-On-Break)For use with water solenoid valves. Adjustable Timer Delay (1-30 seconds) allows well water to cool the milk and plate cooler before shutting off water flow to the plate cooler. This saves unneeded water flow when milk pump is not running.

Dari-Kool® Falling Film Chiller PlatesFor use in Dari-Kool Falling Film Chillers to increase the cooling capacity of chillers not equipped with the maximum number of chiller plates. Note: Remember to provide the necessary water flow through the water distribution trough(s) to supply the number of chiller plates used (35 GPM per plate).

Kit Includes:(1) Plate Assy., Evap, 5 ton(1) Tube, Copper, 1.38 x 6.00, spl(1) Tube, Copper, 1.62 x 6.00, spl(2) Washer, Nprn, 1.25 x 2.50 x .12(2) Washer, Nprn, 1.50 x 2.50 x .12(1) Collar Assy., .75 S 1.38 x 2.25(1) Collar Assy., .75 S 1.69 x 2.75

Cooler Reservoir Partition PlatePartition divider plate allows a 12-plate chiller cabinet to provide two coolant temperatures to dual coolant plate coolers, and maximize compressor capacities. The partition plate effectively splits the lower insulated coolant reservoir in two, so that separate tempera-tures can be run on each side of a 12-plate chiller cabinet. Optional partition plate can be field installed but should be ordered and installed at the factory.

4022869 - Plate Assembly Kit

O R D E R I N F O R M A T I O NFalling Film Chillers 6-plate0.5” NPT Water Solenoid Valve 85030750.75” NPT WaterSolenoid Valve 85030761.0” NPT Water Solenoid Valve 85030771.5” NPT WaterSolenoid Valve 8503078

O R D E R I N F O R M A T I O NDari-Kool Falling Film ChillersPlate Assembly Kit, Evaporator, Chiller, Chiller, 5 ton 4022869Trough Assembly,6-plate (if req. forolder chillers) 4020026

O R D E R I N F O R M A T I O NTimer DelayTimer Delay, 1-30 sec., 230 VAC 8516131

O R D E R I N F O R M A T I O NCooler Reservior Part. PlatePlate, partition, 12-plate cabinet 4023653

8516131 - Timer Delay

4020026 - Trough Assembly

4023653 - Plate, partition

Page 59: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 5 9

CoolingD e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Chiller Accessories

Chiller Water Recirculating Pumps

Water Pump Repair Kit

Consists of:

Ceramic Seal, Seal Spring Retainer, Shaft O-Ring

Expansion Valve Assembly

4020797 -Pump, 2 Hp

4020796 - Pump Repair Kit

4020738 - 5-ton Expansion Valve Assy.

130

120

110

100

90

80

70

60

50

56.4

52.0

47.7

43.4

39.0

34.7

30.3

26.0

21.70

Flow Rate (U.S. gallons per minute)�60 Hz Operation

Pum

p H

ead

(Ft)

Pum

p H

ead

(psi

)

50 100 150 200 250 300 350 400

3 HP�PN 4020793 - 1 Phase�PN 4020818 - 3 Phase

7-1/2 HP�PN 4020795 - 3 Phase5 HP�

PN 4020794 - 3 Phase

10 HP�PN 4024345 - 3 Phase

2 HP�PN 4020797 - 1 Phase�PN 4020817 - 3 Phase

60 Hz Pump On 50 Hz Power No Impeller Change

50 Hz 60 Hz Factor GPM = GPM X .829Head = Head X .687Hp = Hp X .569

O R D E R I N F O R M A T I O NRecirculating PumpsPump 2 Hp, 208-230/460V, 3-phase 4020817Pump, 2 Hp, 115-230V, 1-phase 4020797Pump 3 Hp, 208-230/460V, 3-phase 4020818Pump, 3 Hp, 115-230V, 1-phase 4020793Pump 5 Hp, 208-230/460V, 3-phase 4020794Pump, 7.5 Hp, 208-230/406V, 3-phase 4020795Pump 10 Hp, 208-230/460V, 3-phase 4024345

O R D E R I N F O R M A T I O NWater Pump Repair KitPump Repair Kit, 2Hp, 3Hp, 5Hp, and 7.5 Hp 4020796Pump Repair Kit, 10 Hp 4024347

O R D E R I N F O R M A T I O NExpansion�Valve�Assembly5-ton (60,000 Btuh) Expansion Valve Assy. 4020738

Change of Speed(RPM) How Examples Varies:

GPM Directly Double RPM = (2) x (RPM) = (2) x (GPM) Triple RPM = (3) x (RPM) = (3) x (GPM)

Head Square Double RPM = (2) x (RPM) = (2)2 = (2)(2) = (4) x Head Triple RPM = (3) x (RPM) = (3)2 = (3)(3) = (9) x Head

Hp Cube Double RPM = (2) x (RPM) = (2)3 = (2)(2)(2) = (8) x Hp. Triple RPM = (3) x (RPM) = (3)3 = (3)(3)(3) = (27) x Hp.

Page 60: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 0

Cooling D e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Dari-Kool® Accessories

Dari-Kool® Chiller Accessories

4020883 - Water Regulating Valve 3/4”

4020828 - Water Flow Safety Switch

O R D E R I N F O R M A T I O NDari-Kool® Chiller AccessoriesWater Regulating Valve 3/4 inch 4020883Water Pump Seal Kit (fits 2, 3, 5, and 7.5 Hp pumps) 4020796Water Flow Safety Switch 4020828

Page 61: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 1

CoolingD e a l e r C a t a l o g

C h i l l e r s a n d C o n t r o l s

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Dari-Kool® Accessories continued

Honeywell Temperature Controls

Glacier-Guard™ Tank Mounted Temperature Sensor

4021841 - Sensor, Honeywell

4023261 - Glacier-Guard™ Temperature Sensor

O R D E R I N F O R M A T I O NHoneywell Temp ControlsKit, control, Temp, 1 PRB, 1-Relay 4040027Control Asssembly, Temp, 1 PRB, 4-Relay 4040031Sensory Assy., Electric Temperature Control 4021841

O R D E R I N F O R M A T I O NGlacier-Guard™ ControlGlacier-Guard™ Temperature Sensor 4023261

Page 62: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 2

Cooling D e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems

Design and Application

Capture waste heat energy from your refrigeration system to provide

hot water while allowing your compressor to run more efficiently. Heat

recovery system is a double-walled heat exchanger with water storage

tank that captures lost heat from your cooling system to heat your

water for free. The heated water is then stored in the system until it is

needed. The Therma-Stor® Heat Recovery System is recognized as the

innovative leader in heat recovery technology.

How It Works

In a milk cooling system without a Therma-Stor Heat Recovery System,

the refrigerant removes the heat from the milk being cooled and that

valuable heat escapes into the air. With a Therma-Stor Heat Recovery

System, the refrigerant carrying the heat passes through the double-

walled heat exchanger surrounding the water storage tank and heats

up the water. The Therma-Stor Heat Recovery System also provides

additional condensing surface which improves refrigeration efficiency

because compressor efficiency goes up as condensing temperatures go

down. The end result is faster cooling and prolonged compressor life.

The Therma-Stor Heat Recovery System will reduce compressor run

time, and will cut down on water heating costs by as much as 65%.

Reliable and Adaptable

The industrial glass-lined water storage tank resists corrosion and has two replaceable anodes for extra corrosion

protection. Every new Therma-Stor Heat Recovery System has a five-year limited warranty. This cost-efficient method

of producing hot water fits any milk cooling system, large or small. The Therma-Stor is available in 80 or 120-gallon

capacities. The Therma-Stor II-80 is designed for single

compressor operation. The Therma-Stor II-120 is designed

for one or two compressor operation. The Therma-Stor

III-120 includes a thermostatically controlled 6,000 watt

electric heating element to boost water temperature into

the 170° to 180° range.

Page 63: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 3

CoolingD e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems continued

General Specifications

All standard Therma-Stor® models:

• 1.75 in. (4.5 cm) foam-in-place urethane insulation

• Dual anodes and safety relief valve

• CSA and UL approved

• Includes 5-year warranty

Model Specifications

Compatible Refrigerants: R-12, R-22, R-134a, R-404a, R-502, R-507

* Based on R22 medium temperature system with 15 PSI drop at maximum capacity.

** Based on R404a and R507 medium temperature system with 15 psi drop at maximum capacity.

MAXIMUM REFRIGERATION CAPACITY

APPLICATIONREFR.

CIRCUITS**

MODEL NUMBER

WATER HEATING ELEMENT

INCLUDED

NOMINAL WATER

CAPACITY GAL. (L)

R-507 AND R-404a** R-22*

PART NUMBER

None None Water Storage 0 120-0 No 119 (450.46) 40168504 Tons/Circuit 5 Tons/Circuit Milk Cooler/Chiller 1 II-80-1 No 80 (302.83) 40188753.5 Tons/Circuit 5 Tons/Circuit Milk Cooler/Chiller 2 II-80-2 No 80 (302.83) 40329304 Tons/Circuit 5 Tons/Circuit Milk Cooler/Chiller 2 II-120-2 No 119 (450.46) 40190263.5 Tons/Circuit 5 Tons/Circuit Milk Cooler/Chiller 4 II-120-4 No 119 (450.46) 40315314 Tons/Circuit 5 Tons/Circuit Milk Cooler/Chiller 2 III-120-2 Yes 119 (450.46) 40169757 Tons/Circuit 10 Tons/Circuit Milk Cooler/Chiller 2 II-120-2HF No 119 (450.46) 40189107 Tons/Circuit 10 Tons/Circuit Milk Cooler/Chiller 2 III-120-2HF Yes 119 (450.46) 401654720 Ton/Circuit 27 Ton/Circuit Chiller 2 TS-II-120-2HF No 119 (450.46) 4021577

Page 64: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 4

Cooling D e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems continued

Model Specifications

MODEL NUMBER

DIAMETERINCHES (CM)

HEIGHTINCHES (CM)

WEIGHTPOUNDS (KGS)

PART NUMBER

120-0 28 (71.12) 67 (170.18) 299 (135.62) 4016850II-80-1 24 (60.96) 64 (162.56) 352 (159.66) 4018875II-80-2 24 (60.96) 64 (162.56) 352 (159.66) 4032930II-120-2 28 (71.12) 67 (170.18) 420 (190.50) 4019026II-120-4 28 (71.12) 67 (170.18) 420 (190.50) 4031531III-120-2 28 (71.12) 67 (170.18) 440 (199.58) 4016975II-120-2HF 28 (71.12) 67 (170.18) 420 (190.50) 4018910III_120-2HF 28 (71.12) 67 (170.18) 440 (199.58) 4016547TS-II-120-2HF 29 (73.66) 67 (170.18) 465 (210.92) 4021577

WATER CONNECTION

REFRIGERATION CONNECTION

MODEL NUMBER

INLET/ OUTLET

MID TANK CONNECTION INLET OUTLET

ELECTRICAL SUPPLY POWER

PART NUMBER

120-0 1-1/4 (31.75) 3/4 (19.05) None None NA 4016850II-80-1 3/4 (19.05) None 3/4 (19.05) 5/8 (15.87) NA 4018875II-80-2 3/4 (19.05) None 3/4 (19.05) 5/8 (15.87) NA 4032930II-120-2 1-1/4 (31.75) 3/4 (19.05) 3/4 (19.05) 5/8 (15.87) NA 4019026II-120-4 1-1/4 (31.75) 3/4 (19.05) 3/4 (19.05) 5/8 (15.87) NA 4031531III-120-2 1-1/4 (31.75) 3/4 (19.05) 3/4 (19.05) 5/8 (15.87) 240V/1PH/60Hz 4016975II-120-2HF 1-1/4 (31.75) 3/4 (19.05) 1-1/8 (28.57) 1-1/8 (28.57) NA 4018910III-120-2HF 1-1/4 (31.75) 3/4 (19.05) 1-1/8 (28.57) 1-1/8 (28.57) 240V/1PH/60Hz 4016547TS-II-120-2HF 1-1/4 (31.75) 3/4 (19.05) 1-5/8 (41.27) 1-5/8 (41.27) NA 4021577

Page 65: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 5

CoolingD e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems continued

Therma-Stor® III-120Combines Features of an Excellent Heat Recovery System with Best Water Heating and Storage Technology

• Provides two high-temperature water outputs and an electric auxiliary heating element

• Optional water valve available • Adjustable thermostat (110°F-180°F)• 230V, 6000 Watt electric heating element

O R D E R I N F O R M A T I O NTherma-Stor III-120 4016975Therma-Stor III-120VHF (high capacity) 4016547Optional water valve 4016603

4016975 - Therma-Stor III-120

Page 66: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 6

Cooling D e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems continued

Therma-Stor® II-120Designed to Supplement Existing Air or Water Condensors

• Not intended to completely replace the existing condensor• Same basic design as TS-III but without auxillary electric

heating element

O R D E R I N F O R M A T I O NTherma-Stor II-120-2 4019026Therma-Stor II-120-4 4031531Therma-Stor II-120-2HF(high capacity) 4018910Therma-Stor II-120-2HF(high capacity) 4021577Optional 120gal Tank Stand 4023228

* Meets European Standards

4019026 - Therma-Stor II-120

4031531 - Therma-Stor II-120-4

Page 67: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 7

CoolingD e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems continued

Therma-Stor® II-80-1Designed to Supplement the Existing Air or Water Condenser

• Not intended to completely replace the existing condenser

O R D E R I N F O R M A T I O NTherma-Stor II-80-1 4018875Therma-Stor II-80-2* 4032930Optional 80 Tank Stand 4033335

* Meets European Standards

4018875 - Therma-Stor II-80-1

4052930 - Therma-Stor II-80-2

Page 68: 04_Cooling

© 2011 BouMat i c . L IT00253EN.1201 6 8

Cooling D e a l e r C a t a l o g

H e a t R e c o v e r y S y s t e m

Products in this catalog may not be available in all regions worldwide due to regulatory or other restrictions. Your Price List summarizes all products available in your region.

Therma-Stor® Heat Recovery Systems continued

Therma-Stor® Storage TankInsulated Water Storage Tank

• 120 gallon• Without condenser plate or

heater element• Uses the same glass lined inner

tank as the Therma-Stor® Heat Recovery Units

• Used for additional storage capacity of heated water

Optional Water ValveWater Dump Valve

• For refrigeration compressors operating at 210°F (100°C) for extended periods of time

• Required on older installations where standard air-cooled condenser was omitted from systems

• Calculate water temperature and hours run time to determine need• Without condenser plate or heater element

O R D E R I N F O R M A T I O NWater valve 2-way solenoid 4016603

O R D E R I N F O R M A T I O NTherma-Stor 120 gal. storage tank 4016850

4016850 - Therma-Stor Storage Tank