20
I d i h R li ® 60 i Substation Automation Products Introduction to the Relion ® 670 series Hardware Hardware © SA-T Training 1MRG004718 Section 03 Contents Hardware - General Hardware General Hardware configuration Modules Hardware overview Local HMI Summary Hardware modules Communication Communication Time synchronization © SA-T Training 1MRG004718 Slide 2

03 SEP670 Intro to Relion 670 Series Hardware

  • Upload
    jomaarg

  • View
    233

  • Download
    4

Embed Size (px)

DESCRIPTION

Guia rele 670 abb

Citation preview

I d i h R li6 0 iSubstation Automation ProductsIntroduction to the Relion670 series Hardware Hardware SA-T Training1MRG004718 Section 03Contents Hardware - General HardwareGeneral Hardware configuration Modules Hardware overview Local HMI Summary Hardware modulesCommunication Communication Time synchronization SA-T Training1MRG004718Slide 2Section 03Relion670 series Hardware general Platform based Platform based Closed casings of common look HMI unit with Ethernet PC port Small or medium size Small or medium size graphical display Common modules Easy future hardware additionypossibilities Dimension 1/2, 3/4 or 1/1 of 19 wide and 6Uhigh Mounting flexibility Flush-, semi-flush, wall- and rack mounting Side by side Compression type or ring lug cable termination SA-T Training1MRG004718Slide 3terminationSection 03Relion 670 series Hardware general I/O flexibilityy 0 - 12 - 24 analog inputs with different input combinations 1A or 5A on the CT inputs Up to 220V on the VT inputs 3 to 14 slot positions to be used for binary inputs/outputs and transducer inputs Max 224 binary inputs Max 96 binary outputs Max 24 mA inputs Binary input voltage 24-250 Vdc Binary input voltage 24 250 Vdc LDCM (per LDCM and in each direction) 4 currents and 8 binary signals or or 192 binary signals SA-T Training1MRG004718Slide 4Section 03Relion 670 series Hardware general Time synchronization Time synchronization TCP/IP, Ethernet IEC 61850, DNP 3.0 LON, SPA IRIG-B GPS Binary input CommunicationIEC 61850 8 1 DNP 3 0 IEC 61850-8-1, DNP 3.0 LON, SPA LDCM (C37.94, G.703 or X21) SA-T Training1MRG004718Slide 5Section 03Relion 670 series Hardware general Transformer Input Module TRM11/1 19 case 6U high Transformer Input Module TRM1 and TRM2 (none, one or two) Analog Digital Conversion module ADM1 and ADM2 (corresponds to1/1 19case, 6U highADM1 and ADM2 (corresponds to TRMx) Central Processing Unit NUM (always included) (always included) Input / Output modules BIM, BOM, SOM, IOM and MIM Power supply module PSM (always included)In- / O t tPower SupplyNUMADMTRM SA-T Training1MRG004718Slide 6OutputsSection 03Hardware configuration Backplane modules Universal Backplane Module1/1 19 rackUBM Universal Backplane Module (UBM) 1/1 19 case (from right to left) TRM1 and TRM2, Slot 40, 411/1 19rackUBM, , ADM1 and ADM2, Slot 31, 32 NUM, Slot P30 (always) 1/2 19 caseCBM TRM1, Slot P40 ADM1, Slot P31 NUM, Slot P30 (always)Combined Backplane ModuleUBMSlot no: P1, P3 P13 P30 - P32P40, P41 Combined Backplane Module (CBM) 1/1 19 case (from left to right) PSM Slot 1 (always)1/2 19 rackUBM PSM, Slot 1 (always) 11 CAN-bus slots, Slot 3-13 1/2 19 case PSM, Slot 1 (always)CBM SA-T Training1MRG004718Slide 7 3 CAN-bus slots, Slot 3-5Slot no: P1, P3 P5 P30, P31 P40 Section 03Hardware configuration 1/1 19 case 3 cPCI positionsADMTRMPSMNUMCAN-busPMCPC-MIP1212CAN-masterI/O d l lik BIM BOM SOM11*CAN-busUBMCBMI/O modules like BIM, BOM, SOM, IOM and MIM connected to the CAN-busPSMADMADMNUMTRMTRMCAN-busPMCPC-MIP1212P AAN TT SA-T Training1MRG004718Slide 8View from the front sideSection 03Hardware configuration 1/1 19 case 2 cPCI positionsADM1RMPSMUMCAN bPMCPC-MIP1212A1TRPNCAN-busCBMPC MIP 2 2CAN-masterI/O modules like BIM, BOM, SOM IOM and MIM connected14*CAN-busUBMSOM, IOM and MIM connected to the CAN-bus SA-T Training1MRG004718Slide 9View from the front sideSection 03Transformer input module (TRM) Isolation barrier preventing Isolation barrier preventing disturbances to enter into 670 series Adapt measured values to static Adapt measured values to static circuitry Up to 12 analog inputs can be connected (settable 50 or 60 Hz) connected (settable 50 or 60 Hz) 0 - 6 U, 110-220V rated range 6 -12 I, 1A and/or 5A rated current Connectors (same type for all I/O-modules) Screw compression or Ring lug SA-T Training1MRG004718Slide 10Section 03Transformer input module (TRM1 or 2)1 A 1 A 5 A 5 A 110-220 V 1 A 1 A metering5 A 5 A metering110 220 V9I+3U9 3All except REB6709 3All except REB6705 4 3RET670 RED6707I+5U7 5All except REB6707 5All except REB670 All except REB6701 6 5Customized4 3 5Customized4 3 5Customized4 3 5Customized4 3 5Customized6I+6U6 6All except REB6706 6All t REB6706 6All except REB6703 3 6REL670 SA-T Training1MRG004718Slide 11Section 03Transformer input module (TRM1 or 2)1 A 1 A 5 A 5 A 110-220 V 1 A 1 A metering5 A 5 A metering110 220 V12I12All except REL670 and REC67012All except REL670 and REC6706I6All except REB6706All t REB6706All except REB670 SA-T Training1MRG004718Slide 12Section 03Analog to digital conversion module (ADM1)Analog inputs (from TRM1)P31 P31Mounting position for OEM module (only on ADM1)P31:1cPCIbusP ibl ti iti f Possible mounting position forLDCM, GTM or RS485 modulePossible mounting positionP31:2Possible mounting position for LDCM or GTM moduleP31:3 SA-T Training1MRG004718Slide 13FrontSection 03Analog to digital conversion module (ADM2)Analog inputs (from TRM2)P32cPCIbusPossible mounting position forLDCM or GTM modulesP32:2P32:3 SA-T Training1MRG004718Slide 14FrontSection 03Numerical module (NUM) UBM interfaceP30UBM interfaceMounting position P30:1g pfor SLM moduleP ibl ti iti P30 2 Possible mounting position for IRIG-B or LDCM modulesP30:2Possible mounting position forLDCM moduleP30:3cPCIbusF t SA-T Training1MRG004718Slide 15FrontSection 03Optical Ethernet module (OEM) Communication Communication Ethernet (100 Mbit/s) IEC 61850-8-1 IEC 61850-9-2LE DNP 3.0One or two channels One or two channels Connectors Glass fiber type STP31:1 Glass fiber, type ST Max 1 module per IED Mounted on ADM1 Mounted on ADM1 SA-T Training1MRG004718Slide 16Section 03Serial communication module (SLM) CommunicationRear Communication LON SPA or IEC 60870-5-103 Connectors Glass fiber, type ST Plastic fiber, type HFBR snap-inP30:1p Combination of glass & plastic fiberM 1 d l IED Max 1 module per IED Mounted on NUM SA-T Training1MRG004718Slide 17Section 03Line data communication module (LDCM) Up to 4 modules per IED (option)Rearp p ( p ) Application example Line differential protection Need to exchange large number of binary informationRearinformation Communication: multiplexed, route switched or dedicated fibre using C37.94external modems for G 703 and G 703E1 external modems for G.703 and G.703E1 Different ranges Short range (SR), Multi-mode, 3 km Medium range (MR), Single-mode, 80 km Long range (LR), Single-mode, 120-150 km Connectors SR: Type ST; MR and LR: Type FC SR: Type ST; MR and LR: Type FC Module mounted on ADM and/or on NUM(depending if IRIG-B and RS485 are included and the number of LDCMs) SA-T Training1MRG004718Slide 18Section 03Galvanic LDCM (X21-LDCM) The optical ports in LDCM (C37 94) may be replaced with galvanic The optical ports in LDCM (C37.94) may be replaced with galvanic X21-port (option) Up to 4 modules per IED (same as optical LDCM) Connectors Electrical 15-pole female mini D-sub Module mounted on ADM and/or on NUM (depending if IRIG-B and RS485 are included and number of LDCMs) SA-T Training1MRG004718Slide 19Section 03GPS time synchronization module (GTM) Time Synchronizing (option)Rear Time Synchronizing (option) Number of channels GPS:1 Rear PPS:1 Connectors Antenna 50 Ohm: SMA Optical PPS: Type ST Module mounted on ADM (1p2) SA-T Training1MRG004718Slide 20Section 03Time synchronizing module (IRIG-B) Time Synchronizing usingR Time Synchronizing using a station clock (option) Number of channels Rear IRIG-B:1 PPS:1 Connectors Electrical IRIG-B: BNCP30:2 Optical PPS: Type STModule mounted on NUM Module mounted on NUM SA-T Training1MRG004718Slide 21Section 03Galvanic RS485 communication module (DNP 3.0) Station BusRear Station Bus Communication (option) DNP 3.0Rear Serial communication, alternative for Ethernet communication 2400 19200 Bits/s Connectors RS 485 6-pole Soft ground 2-pole connector Max 1 module per IED SA-T Training1MRG004718Slide 22 Mounted on ADM1Section 03Power supply module (PSM) DC/DC Converter providing full DC/DC Converter providing full isolation between IED and external battery systemP1 Input range: 24-60 V DC or Input range: 90-250 V DC I t l f il l t t Internal fail relay output Connectors (same type for all I/O-modules)) Screw compression or Ring lugFront SA-T Training1MRG004718Slide 23FrontSection 03Binary input module (BIM) 16 Independent Binary Inputs 16 Independent Binary Inputs Debounce filter, T = 5 ms Oscillation suppression detection within 1 s;> 0 - 40 Hz Pulse counting at all inputs (option) Auxiliary voltage Auxiliary voltage 24/40 V DC (20%) 48/60 V DC (20%) 110/125 V DC (20%) 220/250 V DC (20%) Connectors (same type for all I/O- ( ypmodules) Screw compression or Ring lug SA-T Training1MRG004718Slide 24g ugSection 03Binary output module (BOM) 24 Single Output Relays or 24 Single Output Relays or 12 Double pole Command Output Relays Connectors (same type for all I/O-modules)Screw compression or Screw compression or Ring lug SA-T Training1MRG004718Slide 25Section 03Static binary output module (SOM) 6 Fast Static Outputs 6 Fast Static Outputs 48-60 VDC or 110-250 VDC 110 250 VDC Operating time < 1ms 6 Change over Output Relays g p y Connectors (same type for all I/O-modules) Screw compression or Ring lug SA-T Training1MRG004718Slide 26Section 03Binary input/output module (IOM) 8 independent Binary Inputs and 12 8 independent Binary Inputs and 12 Binary Output Relays (10 trip and signal relays, 2 fast signal relays) Fix filter time 5 ms Fix filter time 5 ms Auxiliary voltage 24/40 V DC (20%) 48/60 V DC (20%) 110/125 V DC (20%)220/250 V DC (20%) 220/250 V DC (20%) Connectors (same type for all I/O-modules) Screw compression or Ring lug SA-T Training1MRG004718Slide 27Section 03mA input module (MIM) 6 independent input channels 6 independent input channels Software selected input ranges 0-5, 0-10, 0-20, 4-20 mA, , , 5, 10, 20 mA Resolution: 16 bit Accuracy: 0,1% Connectors (same type for all I/O-modules) Screw compression or Ring lug Ring lug SA-T Training1MRG004718Slide 28Section 03Hardware overview, 1/1 19 case11*CAN 3*PCISLMOEMPSMLDCM(4 pieces)GTMNUMTRM1 TRM2IRIG-B SA-T Training1MRG004718Slide 29ADM1 ADM2 I/ONUMRS485Section 03Hardware overview I/O modules, 1/1 case MIM *)(max 4)IOM(max 6)1/1 CaseBOM *)6 Transducer inputs,setting range+ 20 mASOM *)(max 4)1/1 CaseOption 1: 1 TRMBIM(max 11/14))(max 4)12 binary outputsand 8 binary inputs 14 I/O modulesOption 2: 2 TRM(max 11/14)6 static and 6 change over binary outputs 2 TRM 11I/O modules16 binary inputs24 binary outputs*) Total number of MIM, SOM and BOM must be 4 SA-T Training1MRG004718Slide 30) ,Section 03Hardware overview I/O modules, 3/4 case MIM *)(max 1)IOM(max 5/6)3/4 CaseBOM *)6 Transducer inputs,setting range+ 20 mASOM *)(max 4)3/4 CaseOption 1: 1 TRMBIM(max 5/8))(max 4)12 binary outputsand 8 binary inputs 8 I/O modulesOption 2: 2 TRM(max 5/8)6 static and 6 change over binary outputs 2 TRM 5 I/O modules16 binary inputs24 binary outputs*) Total number of MIM, SOM and BOM must be 4 SA-T Training1MRG004718Slide 31Section 03Hardware overview I/O modules, 1/2 case MIM(n.a.)IOM(max 3)1/2 CaseBOM6 Transducer inputs,setting range+ 20 mASOM(max 3)1/2 Case 1TRM 3 I/O modulesBIM(max 3)(max 3)12 binary outputsand 8 binary inputs(max 3)6 static and 6 change over binary outputs16 binary inputs24 binary outputs SA-T Training1MRG004718Slide 32Section 03Hardware overview I/O modules, Ring lugs 1/1 Case 3/4 Case 1/1 CaseOption 1: 1 TRM3/4 CaseOption 1: 1 TRM1/2 Case 7 I/O modulesOption 2: 2 TRM 4 I/O modulesOption 2: 2 TRM 1TRM 1 I/O modules 2 TRM 5 I/O modules 2 TRM 2 I/O modules SA-T Training1MRG004718Slide 33Section 03Local HMI Small or medium size screen Small or medium size screen Graphical LCD display (80 x 240 or 320 x 240 pixels)3 status indication LEDs indicate the 3 status indication LEDs indicate the status of the IED Ready, Start and Trip 15 indication LEDs 12 push buttons for navigation, control etc. Ethernet front port connection, RJ45 SA-T Training1MRG004718Slide 34Section 03Summary Basic hardware modules Universal Backplane Module (UBM) p ( ) Combined Backplane Module (CBM) Main Processing Module (NUM)Power Supply Module (PSM) Power Supply Module (PSM) SA-T Training1MRG004718Slide 35Section 03Summary Specific hardware modules Binary Input Module (BIM) y p ( ) Binary Output Modules Relay outputs (BOM) Static and relay outputs (SOM) Binary I/O Module (IOM) mA input Module (MIM) Analog Input Module (TRM) Analog to Digital conversion Module (ADM) Data communication Module (LDCM) Optical (C37.94) or galvanic (X21) Serial communication Modules LON, SPA or IEC 60870-5-103 (SLM) DNP 3.0 galvanic (RS485) Optical Ethernet Module (OEM) Time Synchronization Modules GPS (GTM)IRIG B SA-T Training1MRG004718Slide 36 IRIG-BSection 03Summary Communication OEM (TCP/IP, Ethernet, SA-system) OEM (TCP/IP, Ethernet, SA system) IEC 61850-8-1 IEC 61850-9-2LEDNP 3 0 DNP 3.0 SLM (Serial Communication Module) LON (SA-system) SPA or IEC 60870-5-103 (SMS-system) RS485 (SA-system) DNP 3.0 LDCM (communication between IEDs) IEEE/ANSI C37.94 IEEE/ANSI C37.94 G.703/G.703E1 optical to galvanic conversion X21-modem connection SA-T Training1MRG004718Slide 37ode co ec oSection 03Summary Time synchronization OEM (TCP/IP, Ethernet) OEM (TCP/IP, Ethernet) IEC 61850-8-1 DNP 3.0 SLM (Serial Communication Module) LON SPA SPA RS485 DNP 3.0 GSM (GPS module) IRIG-B Electrical IRIG-B Electrical IRIG B Optical PPS Binary input SA-T Training1MRG004718Slide 38Section 03 SA-T Training1MRG004718Slide 39