2 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Nokia Siemens Networks
AcademyLegal notice
Intellectual Property RightsAll copyrights and intellectual property rights for Nokia Siemens Networks trainingdocumentation, product documentation and slide presentation material, all of which are forthwithknown as Nokia Siemens Networks training material, are the exclusive property of NokiaSiemens Networks. Nokia Siemens Networks owns the rights to copying, modification,translation, adaptation or derivatives including any improvements or developments. NokiaSiemens Networks has the sole right to copy, distribute, amend, modify, develop, license,sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals
can use the Nokia Siemens Networks training material for their own personal self-developmentonly, those same individuals cannot subsequently pass on that same Intellectual Property toothers without the prior written agreement of Nokia Siemens Networks. The Nokia SiemensNetworks training material cannot be used outside of an agreed Nokia Siemens Networkstraining session for development of groups without the prior written agreement of NokiaSiemens Networks.
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
3/25
3 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
At the end of this module the trainee should be able to:
Edit the common adjacency optimisation parameters for a
separate deletion or creation of adjacencies
Set the required parameters for the automatic measurement-
based adjacency optimisation
Perform adjacency optimisation
Module Objectives
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
4/25
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
5/25
5 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Prerequisites
Invalid adjacencies fixed
Antennas defined for every cell
Interference matrix availableAdjacency Optimisation KPIs available for Adjacencies
Adjacency Constraints have been created or imported
Adjacency templates have been created for each object typeTemplate assignment rules have been created
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
6/25
6 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Methods and Startup
Creation based on IM values, deletion based on ADCE KPIsCheck the KPI date and summarisation level
Select target objects from the Navigator, Map or Browser
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
7/25
7 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Starting GSM Adjacency Optimisation
Only ADCEs selected for measurement-based GSMadjacency optimisation
CIP or FEP can also be selected if available
Check the retrieved IM sets and priorities
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
8/25
8 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Adjacency Optimisation Tool View
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
9/25
9 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
GSM Adjacency Optimisation
How can I start the measurement-based adjacency
optimisation?
How can I find the unused (unnecessary) adjacencies (deletion
plan)?
find the missing adjacencies (creation plan)?
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
10/25
10 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Common Parameters
Bidirectional optimisation(recommended)
Creation and deletion of
adjacencies into and out fromscope allowed(recommended for smallscopes)
Check maximum and minimumAdjacency List Lengths
Changes to adjacenciesbetween frequency bands
can be disabledFrequency band specific list
length settings can beenabled
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
11/25
11 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Deletion Options for All Adjacency Types
Deleting outgoingadjacencies to foreigntarget cells can beallowed
Adjacencies withoutmeasurements will have 0
values for KPIs and aredeleted
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
12/25
12 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Deletion Parameters for ADCE
Bidirectionaldeletion requires atleast one bad valuein both directions
Additionalconditions can beused to avoiddeleting adjacenciesin low traffic cells
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
13/25
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
14/25
14 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Detailed Results on Deleted
Infocolumn shows the creation/deletion reason
Include Changecolumn defines the results to be saved inthe plan
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
15/25
15 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Saving the Results
The results must be saved to the plan
Save is possible only to the plan that is open when AdjacencyOptimisation starts, or to a plan that is created after pressing
SaveAfter the save the results can be listed to Browser or shownon the map
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
16/25
16 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Exercise
Check and set Commonparameters
Set Deletionparameters and start the optimisation
View the results and check different views in the AdjacencyBrowser
Change parameters and run again
Save the results into your plan
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
17/25
17 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
GSM Adjacency Optimisation
How can I start the measurement-based adjacency
optimisation?
How can I
find the unused (unnecessary) adjacencies (deletionplan)?
find the missing adjacencies (creation plan)?
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
18/25
18 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Creation Options for All Adjacency Types
Creating BCCH and BCCH-BSIC collisions can be allowed ifFrequency Optimisation is done in the same plan
Normally BCCH or BCCH-BSIC collisions are not allowed
If there are existing collisions in the network no new adjacencies are
created for those cells unless collisions are allowed
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
19/25
19 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Creation Thresholds
Bidirectional creation requires good values in the outgoing direction
25 RXLEV = -96 dBm ( -95dbm)
Theta angle limitation not necessary (because of the measurements)
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
20/25
20 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Adjacency Optimisation
Start optimisation. Beforestarting, check that Deletionis not selected.
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
21/25
21 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Detailed Results on Created
Infocolumn shows the creation/deletion reasonInclude Changecolumn defines results for the save
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
22/25
22 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Results
Save the resultsLocate on Map or List to Browser to check the templates
You can select all by pressing Ctrl-A
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
23/25
23 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Exercise
Check and set Commonparameters
Uncheck Delete Adjacenciesbox in the Deletiontab
Set Creationparameters and find the missing adjacencies inyour scope
View the results in the Adjacency Browser
Change parameters and run again
Save the results into your plan
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
24/25
24 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Summary
Prerequisites
Site assignments and Antennas correctly defined
Adjacency templates and template assignment rules defined
Adjacency Constraints defined
Measurement-based deletion of GSM adjacencies Common Parameters
Deletion based on KPI values
Measurement-based creation of GSM adjacencies
Common Parameters Creation based on Interference Matrix values
Results saved in to the plan Plan that is open when the tool is started
Plan that is created after pressing the Save button
After the save the results can be located on the Mapand listed to the Browser
7/28/2019 03 GSM Adjacency Optimisation OPT 3.0
25/25
25 Nokia Siemens Networks Presentation / PLe /23.8.2010
For public use IPR applies
Document change history
First version for Optimizer 3.0PLe1.023.8.2010
Change commentNameVersionDate