03 GSM Adjacency Optimisation OPT 3.0

Embed Size (px)

Citation preview

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    1/25

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    2/25

    2 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Nokia Siemens Networks

    AcademyLegal notice

    Intellectual Property RightsAll copyrights and intellectual property rights for Nokia Siemens Networks trainingdocumentation, product documentation and slide presentation material, all of which are forthwithknown as Nokia Siemens Networks training material, are the exclusive property of NokiaSiemens Networks. Nokia Siemens Networks owns the rights to copying, modification,translation, adaptation or derivatives including any improvements or developments. NokiaSiemens Networks has the sole right to copy, distribute, amend, modify, develop, license,sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals

    can use the Nokia Siemens Networks training material for their own personal self-developmentonly, those same individuals cannot subsequently pass on that same Intellectual Property toothers without the prior written agreement of Nokia Siemens Networks. The Nokia SiemensNetworks training material cannot be used outside of an agreed Nokia Siemens Networkstraining session for development of groups without the prior written agreement of NokiaSiemens Networks.

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    3/25

    3 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    At the end of this module the trainee should be able to:

    Edit the common adjacency optimisation parameters for a

    separate deletion or creation of adjacencies

    Set the required parameters for the automatic measurement-

    based adjacency optimisation

    Perform adjacency optimisation

    Module Objectives

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    4/25

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    5/25

    5 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Prerequisites

    Invalid adjacencies fixed

    Antennas defined for every cell

    Interference matrix availableAdjacency Optimisation KPIs available for Adjacencies

    Adjacency Constraints have been created or imported

    Adjacency templates have been created for each object typeTemplate assignment rules have been created

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    6/25

    6 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Methods and Startup

    Creation based on IM values, deletion based on ADCE KPIsCheck the KPI date and summarisation level

    Select target objects from the Navigator, Map or Browser

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    7/25

    7 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Starting GSM Adjacency Optimisation

    Only ADCEs selected for measurement-based GSMadjacency optimisation

    CIP or FEP can also be selected if available

    Check the retrieved IM sets and priorities

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    8/25

    8 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Optimisation Tool View

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    9/25

    9 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    GSM Adjacency Optimisation

    How can I start the measurement-based adjacency

    optimisation?

    How can I find the unused (unnecessary) adjacencies (deletion

    plan)?

    find the missing adjacencies (creation plan)?

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    10/25

    10 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Common Parameters

    Bidirectional optimisation(recommended)

    Creation and deletion of

    adjacencies into and out fromscope allowed(recommended for smallscopes)

    Check maximum and minimumAdjacency List Lengths

    Changes to adjacenciesbetween frequency bands

    can be disabledFrequency band specific list

    length settings can beenabled

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    11/25

    11 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Deletion Options for All Adjacency Types

    Deleting outgoingadjacencies to foreigntarget cells can beallowed

    Adjacencies withoutmeasurements will have 0

    values for KPIs and aredeleted

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    12/25

    12 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Deletion Parameters for ADCE

    Bidirectionaldeletion requires atleast one bad valuein both directions

    Additionalconditions can beused to avoiddeleting adjacenciesin low traffic cells

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    13/25

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    14/25

    14 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Detailed Results on Deleted

    Infocolumn shows the creation/deletion reason

    Include Changecolumn defines the results to be saved inthe plan

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    15/25

    15 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Saving the Results

    The results must be saved to the plan

    Save is possible only to the plan that is open when AdjacencyOptimisation starts, or to a plan that is created after pressing

    SaveAfter the save the results can be listed to Browser or shownon the map

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    16/25

    16 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Exercise

    Check and set Commonparameters

    Set Deletionparameters and start the optimisation

    View the results and check different views in the AdjacencyBrowser

    Change parameters and run again

    Save the results into your plan

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    17/25

    17 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    GSM Adjacency Optimisation

    How can I start the measurement-based adjacency

    optimisation?

    How can I

    find the unused (unnecessary) adjacencies (deletionplan)?

    find the missing adjacencies (creation plan)?

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    18/25

    18 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creation Options for All Adjacency Types

    Creating BCCH and BCCH-BSIC collisions can be allowed ifFrequency Optimisation is done in the same plan

    Normally BCCH or BCCH-BSIC collisions are not allowed

    If there are existing collisions in the network no new adjacencies are

    created for those cells unless collisions are allowed

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    19/25

    19 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creation Thresholds

    Bidirectional creation requires good values in the outgoing direction

    25 RXLEV = -96 dBm ( -95dbm)

    Theta angle limitation not necessary (because of the measurements)

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    20/25

    20 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Optimisation

    Start optimisation. Beforestarting, check that Deletionis not selected.

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    21/25

    21 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Detailed Results on Created

    Infocolumn shows the creation/deletion reasonInclude Changecolumn defines results for the save

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    22/25

    22 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Results

    Save the resultsLocate on Map or List to Browser to check the templates

    You can select all by pressing Ctrl-A

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    23/25

    23 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Exercise

    Check and set Commonparameters

    Uncheck Delete Adjacenciesbox in the Deletiontab

    Set Creationparameters and find the missing adjacencies inyour scope

    View the results in the Adjacency Browser

    Change parameters and run again

    Save the results into your plan

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    24/25

    24 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Summary

    Prerequisites

    Site assignments and Antennas correctly defined

    Adjacency templates and template assignment rules defined

    Adjacency Constraints defined

    Measurement-based deletion of GSM adjacencies Common Parameters

    Deletion based on KPI values

    Measurement-based creation of GSM adjacencies

    Common Parameters Creation based on Interference Matrix values

    Results saved in to the plan Plan that is open when the tool is started

    Plan that is created after pressing the Save button

    After the save the results can be located on the Mapand listed to the Browser

  • 7/28/2019 03 GSM Adjacency Optimisation OPT 3.0

    25/25

    25 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Document change history

    First version for Optimizer 3.0PLe1.023.8.2010

    Change commentNameVersionDate