Upload
wilmer-mauricio-luna
View
214
Download
0
Embed Size (px)
Citation preview
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
1/204
ARGUS
1ARGUS 28
ARGUS 28Manual
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
2/204
ARGUS
2 ARGUS 28
© by intec Gesellschaft für Informationstechnik mbHD-58507 Lüdenscheid, Germany, 2005
Alle Rechte, auch der Übersetzung, vorberhalten. Kein Teildes Werkes darf in irgendeiner Form (Druck, Fotokopie,Mikrofilm oder einem anderen Verfahren) ohne schriftlicheGenehmigung reproduziert, vervielfältigt oder verbreitetwerden.
All rights are reserved. No portion of this document may be
reproduced, duplicated or distributed in any form (print,copies, microfilm or on any other media) without intec’swritten permission.
Version: 3.0
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
3/204
ARGUS
3ARGUS 28
1 Introduction ......................................................... 7
2 Safety Instructions ........................................... 11
3 Technical data ................................................... 12
4 Operation - a brief guide .................................. 13
5 Menu Hierarchy ................................................ 17
6 Start-Up ............................................................. 23
7 Setting the type of access ............................... 337.1 Operation on a U-interface access ................. 34
8 Setting the Access Mode ................................. 358.1 Operation on a BRI, U-Interface or PRI ........... 35
8.1.1 TE-Simulation mode .................................. 358.1.2 NT-Simulation mode .................................. 358.1.3 Permanent circuit ....................................... 378.1.4 BRI/PRI Monitor ......................................... 468.1.5 BRI/ PRI Recorder ..................................... 498.1.5.1 Administration of the recorded data ........ 51
8.2 Operation on a POTS (analog) access ........... 568.2.1 POTS terminal ........................................... 568.2.2 POTS monitor ............................................ 56
9 Operation on an X.21 or V.35 Access ............. 589.1 Start BERT ......................................................... 59
9.1.1 Display the test results .............................. 609.1.2 Saving the test results in the ARGUS ........ 60
9.2 BERT wait .......................................................... 61
10 SHDSL Tests ..................................................... 6310.1 - SHDSL Line Test ............................................ 6410.2 Displaying the stored results ......................... 7210.3 Bit error test ..................................................... 73
10.3.1 BERT start ............................................... 7410.3.2 BERT wait ................................................ 7810.3.3 B-channel loop ......................................... 79
10.4 Telephony on permanent circuits ................... 80
11 Single Tests ...................................................... 8111.1 Test the Supplementary Services ................... 81
11.1.1 Suppl. Services Test on 1TR6 ................. 8111.1.2 Suppl.service interrogation in DSS1 ........ 8311.1.3 Suppl. Services Tests – Error messages 87
11.2 Service check .................................................... 8811.3 Bit error test ...................................................... 9211.3.1 Start BERT .............................................. 9411.3.1.1 BERT - saving ...................................... 97
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
4/204
ARGUS
4 ARGUS 28
11.3.1.2 Displaying the stored results ................ 9911.3.2 BERT wait ............................................. 10011.3.3 B-channel loop ...................................... 101
11.4 X.31 Test ......................................................... 10211.4.1 Automatic X.31-Test .............................. 102
11.4.2 Manual X.31 Test .................................. 10811.5 CF Interrogation ............................................. 11211.6 CF - Activation ................................................ 11411.7 CF - Delete ...................................................... 11511.8 MSN Interrogation .......................................... 11611.9 Traffic generator (only on a PRI access) ..... 11711.10Time measuring ............................................. 119
11.10.1 Connection setup time ........................ 12011.10.2 Time measurement: B-channel delay . 12111.10.3 Time measurement: Interchannel delay 122
12 Connection ..................................................... 12512.1 Setting up an ISDN connection ..................... 12512.2 Clearing down an ISDN connection ............. 13212.3 Operation on a POTS (analog) access ......... 134
13 Test Manager .................................................. 13713.1 Simultaneously Starting Several Tests ........ 13813.2 Switching Between Tests .............................. 14113.3 Cancel All ........................................................ 141
14 Automatic Tests ............................................ 14214.1 Automatic Start test ....................................... 14514.2 Display Results .............................................. 14814.3 Sending the results of a tests to a PC .......... 15014.4 Deleting the results of a test ......................... 15114.5 Sending the results of all tests to a PC ........ 152
15 Level Measuring ............................................ 15315.1 Level measuring on a BRI access ................ 153
15.2 Voltage measurement on a U-interface ........ 15515.3 Voltage measurement on a POTS access .... 155
16 L1 status ......................................................... 15616.1 The L1 status of a BRI access ...................... 15616.2 The L1 status of a PRI access ....................... 157
17 Configuration .................................................. 16017.1 Trace/Remote ................................................. 16017.2 Setting the SHDSL parameters ..................... 161
17.3 Configuration: ISDN ....................................... 16317.4 Configuration: BERT ...................................... 17017.5 Configuration: POTS ...................................... 17417.6 Configuration: X.31 profile ............................ 178
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
5/204
ARGUS
5ARGUS 28
17.7 Configuration: ARGUS ................................... 18217.8 Saving Call Numbers ...................................... 18517.9 Reset ................................................................187
18 Accu servicing ................................................ 190
19 Testing Features with the Keypad ................ 19220 Connection for a PRI network ....................... 19320.1 ARGUS connector Pin Assignments ............ 19320.2 Connection to DTAG NTPM ........................... 19420.3 The ARGUS 28 as Terminal ........................... 194
21 Appendix ......................................................... 195A) Acronyms ....................................................195B) CAUSE-Messages – DSS1 Protocol ..........198C) CAUSE-Messages – 1TR6 Protocol ...........200D) ARGUS Error Messages ........................... 202
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
6/204
ARGUS
6 ARGUS 28
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
7/204
1 Introduction
7ARGUS 28
1 Introduction
The ARGUS 28 is a compact all-in-one tester, which can beexpanded in individual steps from a SHDSL tester all theway to a universal tester for E1, X.21, V.35, PRI, BRI and
POTS interfaces.
ARGUS 28 expansion levels:- Basic tester : SHDSL both remote and central ends,WINplus- Options :
- SHDSL 4-wire interface- POTS interface- Packet 1: PRI and BRI, WINanalyse- Packet 2: E1/PRI, extended BERT, BERT nx64 kBit/s,
MegaBERT, USB adapter- X.21 interface with X.21 cable- V.35 interface with V.35 cable- U-interface (4B3T)- U-interface (2B1Q)
The basic ARGUS 28 supports network operatorsparticularly in the installation and setup of the 2-wire SHDSLsystems. In this case, the ARGUS simulates both thenetwork and the customer side of the SHDSL connection.Even the customer's terminal equipment can be included inthe measurement process by simply connecting it to theoutput on the ARGUS 28, which then serves as a SHDSLmodem.With its rechargeable batteries and internal charger, theARGUS is exceptionally well suited for use in field service.The intuitive menu operation combines convenient cursorkeys and softkeys with a four-line backlit display.
Besides TE/NT simulation on BRI and PRI accesses, theARGUS 28 also supports TE simulation on U interfaces(optional) and POTS as well as convenient BRI and PRI D-channel monitoring. The 16 megabytes of internal Flashmemory enables the tester to record and save themonitoring data without requiring a connection to computer.
The Flash-ROM technology permits you to upgrade yourARGUS at any time by download software updates from aPC (free software updates are available at www.argus.info).
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
8/204
1 Introduction
8 ARGUS 28
If you use the ARGUS on a BRI or PRI interface in an ISDNsystem whose specifications deviate from the (DIN ETS 300102) standard (e.g. some networked PBXs), you must takethese manufacturer-specific modifications into account. Insuch cases, please contact the distributor of your ISDN PBXfor assistance.
To test X.21/V.35 permanent circuits, you can connect theARGUS to the X.21/V.35 network via the X.21/V.35 adapter.
As an option, a V5.x monitor is available for the ARGUS 28:This monitor can be used to record the V5.1 or V5.2protocol, which can then be decoded in detail with theWINanalyse software. The ARGUS Functions - Overview:
SHDSL test
Displays the SHDSL connection's most importantperformance parameters
Bit error tests (BERT) for SHDSL
Performs a BERT to a loopbox or in end-to-end operation.
The ARGUS will, if needed, handle the loopbox functionitself.
Listen/Talk mode (telephony) in TDM time slices
Tests a permanent circuit using a telephone connection to aremote end in a selected time slice.
Protocol Recognition and B-Channel Test for ISDN
Accesses
After you select the operation mode, the ARGUS willautomatically determine the protocol supported by theaccess under test and will then test the availability of the B-channels.
Telephone connections
Can a telephone call be placed from this access to everyother number and/or can this access receive a call?
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
9/204
1 Introduction
9ARGUS 28
Service Tests
Does the tested access support connections with the mostimportant services, such as, ISDN telephone service, Group4 - Facsimile or data transmission at 64 kbit/s etc.?Additionally, 3 user-specific services can be saved in the
ARGUS and tested on the access under test.
Bit error tests (BERT) for E1, PRI, BRI, U-interfaceaccesses
Performs a BERT in an extended call to itself via a loopboxor in end-to-end operation. The ARGUS will, if needed,handle the loopbox function itself.The integrated MegaBERT extends the bit error test on E1/ PRI accesses to a full 2 Mbit/s bandwidth. Any distribution
of time slots (n x 64 kBit/s ) may be used.Supplementary Services
The ARGUS automatically tests the supplementary servicesmade available by the exchange.
Leased Line Tests – tests permanent circuits with BERTand speech
NT simulation of a BRI or a PRI access
D-channel monitoring on a Basic Rate Interface and ona Primary Rate InterfaceAll of the D-channel signals are captured and passed to theserial interface. When passively monitoring, the ARGUSdoes not affect Layer 1.
POTS (analog) Functionality
Does the POTs access support call number transfer?The ARGUS will display the charges, if the access supportsthis feature.
Monitoring an analog line (passive listening-in)
CF Interrogation
The ARGUS will check, whether a call diversion has beensetup on the access under test. The ARGUS can setup orclear down call diversions in the exchange.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
10/204
1 Introduction
10 ARGUS 28
MSN interrogation (only on a BRI access)
On a P-MP access using the DSS1 protocol, the ARGUSwill determine the MSNs of the access under test.
X.21/V.35 TestThe ARGUS will perform a bit error test on the X.21/V.35access in accordance with the ITU guidelines G.821 andG.826.
The Access Acceptance Report
When the ARGUS is linked to a PC via the serial interface, itis, as an example, possible - with the aid of WINplus - to
create and print a comprehensive test report on the PC. Testing Features with the Keypad
Supports manual tests in the so-called keypad mode. If thenetwork supports this feature, the user can send acommand sequence and can then test service features in adialog.
Should you have any further questions, please contact us:intec Gesellschaft für Informationstechnik mbH
Rahmedestr. 90D-58507 Lüdenscheid
Tel.: +49 (0) 2351 / 9070-0Fax: +49 (0) 2351 / 9070-70
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
11/204
2 Safety Instructions
11ARGUS 28
2 Safety Instructions
The ARGUS may only be used with the includedaccessories. Usage of other accessories may lead toerroneous measurements and may even cause damage to
the ARGUS and the connected installation.
The ARGUS is only to be used in accordance with theinstructions in this documentation. Any other usage mayresult in bodily injury and destruction of the ARGUS.
• To prevent electrical shocks or damage to the ARGUS,do not connect it to lines with voltages in excess of 100V!
• Never attempt a measurement with the case open!
• The ARGUS is not watertight. Protect the ARGUS fromexposure to water!
• Before replacing the battery(see page 16 Replacing theaccumulators), disconnect all the test leads and switchthe ARGUS off.Make certain that the polarity is correct when
connecting the batteries!
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
12/204
3 Technical data
12 ARGUS 28
3 Technical data
Dimensions / Weight
Height 229 mmWidth 72 mmDepth 35 mmWeight 350 g (withoutbatteries and protectivecase)Keypad21 Keys
LCD displayLCD display withswitchablebackground lighting4 lines with 16 characters
MemoryEEPROM Non-volatilememory: 2048BytesFlash programmemory: 1 Mbyte
S-RAM: 256 Kbytes +128 Kbytes
Data memory: 16 Mbyte(Flash)
Inputs / Outputs
1 RJ-45 for BRI, PRI,
U-interface (optional) orPOTS
1 jack for an externalpower supply
1 RJ45 forconnecting to an X.21or V.35 network or a PC
1 RJ -11 for SHDSL
Temperature RangesAmbient-temperature:0 °C to +50 °C
Operatingtemperature:-5 °C to +55 °C
Power
Supply3 NiMH accumulatorsor
9 V, plug-in powersupplyor
BRI feed
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
13/204
4 Operation - a brief guide
13ARGUS 28
4 Operation - a brief guide
Power Key:
- Switch the ARGUS ON- To start up again after a power down- to switch on the display backlighting In battery mode to save power, the
backlighting will switch off automaticallyafter 5 seconds.- To switch the ARGUS OFF (must be pressed somewhat longer) Confirmation key:
- Select menu or continue
Receiver inset
LEDs
Softkeys
Menu control
Confirmation key
Layer 1 measurement
Pickup / Hang upCalling
Power /
MicrophoneFastener forshoulder strap
Numerical
LCD display4x16 characters
Display backlighting
keypad
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
14/204
4 Operation - a brief guide
14 ARGUS 28
Menu control:
- Open the menu list- Scroll through lists- Select a menu- Select a function in an
open menuTelephony - Pickup or hang up- Simplified overlap signalling: press the telephone key twice.
Layer 1 measurement:
start the Layer 1 measurement(Level/Voltage)
Number Pad:
- Entry of the digits 0....9 and of the special characters *, # (e.g. the call number
or numerical entry in a function)- In special cases entry of alphanumeric
characters- Direct function call
Softkeys:The function of the 3 softkeys varies with thesituation. The current function of each softkeyis shown in the highlighted fourth line of thedisplay.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
15/204
4 Operation - a brief guide
15ARGUS 28
Connectors on the end:
• 9 V-
Connection for the external power supply.If the plug-in power supply is connected, the ARGUS willautomatically disconnect the accumulators. In this case,the ARGUS will automatically recharge the
accumulators(see page 190 Accu servicing).
• Line
- Connection for a BRI network- Connection for a POTS (analog network)- Connection for a PRI network
• DSL
- Connection for the SHDSL network
• X.21, V.35 / PC
- Connection for the X.21 or V.35 adapter- Connection to a PC via a serial cable- Connection of a PC via the USB Adapter
Pin Assignment3/4/5/6BRI7/8 POTsPIN assignment for PRI, see “Connectionfor a PRI network” on page 193.
Western 4 jack - SHDSL:
1 Line2 a (TIP)2 Line1 a (TIP)3 Line1 b (RING)4 Line2 b (RING)
P110
1234
WESTERN4SMD
TIP_2TIP_1
RING_1RING_2
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
16/204
4 Operation - a brief guide
16 ARGUS 28
Replacing the accumulators
The battery compartment for the three accumulators(rechargeable batteries) is located on the back of the case.Unscrew the screws to remove the cover of the case andinsert the accumulators in accordance with the polarity
marking.
Use only NiMH accumulators.
The current state of the charge will (if the ARGUS is notconnected to a power supply) be displayed graphically.
In the LCD display, a battery symbol will begin to blink, whenthere is still approximately 5 minutes reserve. During thisperiod, it is possible that there may be audible interferenceand in rare cases even malfunctions (see “Accu servicing”on page 190.).
Power Down
In accu/battery operation, if the ARGUS is idle for 15minutes, it will automatically switch to the power-down mode(power-down).The ARGUS will remain in power-down mode until thePower-Key is pressed again.
Reasonably enough, the ARGUS willnot enter power-downmode during a test (e.g. Loopbox) or when it is in Tracemode.
As an alternative, it is possible to operate the ARGUS usingthe included power supply. If the ARGUS is connected tothe plug-in power supply, it will automatically disconnect theaccumulators and will - reasonably enough - not enterpower-down mode.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
17/204
5 Menu Hierarchy
17ARGUS 28
5 Menu Hierarchy
MenuAccess
Selection of the physicalaccess
SHDSL page33Basic Rate Interface(optional) page 33Primary Rate Interface(optional) page 33POTS interface (optional)
The Access Mode menu willopen automatically
MenuAccess mode
TE automatic page 35TE P-P page35TE P-MPpage 35NT P-P page35NT P-MP page
BRI
POTS terminal page56
PO
STU-C 2-wire page 64STU-R 2-wire page 64STU-R 2-wire/PRI page
SHDSL
A list of all the menus willopen
Switch the ARGUSON
BRI, PRI, U-Interface,POTS, X21 or V.35 Autodetect: The ARGUSdetermines whether it is aBRI, PRI or POTSaccess.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
18/204
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
19/204
5 Menu Hierarchy
19ARGUS 28
Menu Level Measuring
Remote end page 153other TE page 153
BRI,
Polarity page 155PO
Menu
Settings
Trace/Remote page160
SHDSL config. page161
- Spectrum- Clock/framing- Chan. selection- Power back off- EOC using- EOC mode
ISDN page
163- L1 permanent?- Protocol- Alerting mode- Clock mode- BRI termination- PRI termination- Sensitivity- Sa5 bits- Sa6 bits
- A bit- CRC4 mode- Call parameter
The ARGUS can beconfigured to suit your specialrequirements.The parameters are clearlyorganized in submenus (e.g.the SHDSL parameters are inthe SHDSL submenu)The default (factory) settingscan be restored by selecting
"Reset“.
MenuAutomatic Tests
Start page 145View page148Test data to PC page150
Delete page 151
The ARGUS will automaticallyexecute the test sequence and save the resultsin its internal Flash
MenuL1 status
The ARGUS displays the current status ofLayer 1 on a BRI access (page 156 ) and theLayer 1 parameter on a PRI access (page157 ).
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
20/204
5 Menu Hierarchy
20 ARGUS 28
- DTMF / Keypad- Dest. no. MSN- CUG Index
BERT page171
- BERT duration(time)
- Error level- HRX value- Bit patt. BRI/U- Bit patt. PRI- Bit patt. SHDSL- Bit patt. X.21
POTS page
174- POTS dial- POTS CLIP- AOC pulse- DTMF parameter- FLASH time
X.31 profile page178
- Packet number
- TEI- LCN- Packet size- Agree PS- Window size- Agree WS- Throughput- Agree DS- User data- CUG- CUG Index- D bit- Facilities- Profile name
Device:page 182
- Menu language- LCD contrast- Date / Time- Baud rate- Alarm- Feed- Battery type
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
21/204
5 Menu Hierarchy
21ARGUS 28
Menu Accu servicing
Charging page 190Discharging
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
22/204
5 Menu Hierarchy
22 ARGUS 28
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
23/204
6 Start-Up
23ARGUS 28
6 Start-Up
Using the included cable, connect the ARGUS to the accessto be tested.
Power Key: Switch on the ARGUS.The ARGUS displays theaccess and modeparameters which were lastselected.
Displayed in the first line:The software version number: 2.9 (in the example)Country code: u (=Great Britain), e (=Spain),f (=France), . . .The state of the accumulator charge (if it is not connected tothe plug-in power supply)
Displayed in the third line:
Type of access: SHDSL, optional: BRI, U-interface, PRI ,POTS or X.21 or V.35 test
Operation mode: STU-C 2-wire.(Access mode) STU-R 2-wire.
STU-R/PRI
NT = NT SimulationTE = TE SimulationPerman.swit.MonitorRecorderTerminal (only on a POTS (analog)
access)
Bus configuration: P-P = point-to-pointP-MP= point-to-multipoint
Displayed in the fourth line:
The fourth line displays the current assignment of the threesoftkeys below.
The ARGUS is in largest part operated with the two↓ ↑ -Keys, the confirmation key and the three softkeys.On the following pages, only the softkey's meaning in the
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
24/204
6 Start-Up
24 ARGUS 28
respective context is shown - enclosed in brackets , e.g.< NO >.The < > softkey serves the same function as theconfirmation key and the softkey performs the samefunction as the corresponding arrow key on the ARGUSkeypad.
Using the ↓ ↑ -Keys or the softkey select the physicalaccess corresponding to that of the access under test.If Automatic is selected in this menu, the ARGUS will
Level ofbatteries' charge
The
currentassignmentof thesoftkeys willbe displayed.
Activation of the displayedparameters. The ARGUS will beginthe initialization phase and thenshow the status display (see Chap.page 30).
The displayed parameters will notbe accepted.The Access menu will now open(Page 33):
Operating modeType ofaccess
Software version:
MarkedType ofaccess
The list
continues
Return toStartingwindow
Name ofthe menu
The ARGUS acceptsthe type of function/ submenu marked with→ .TheAccess Mode menu willopen.
scrollfurther.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
25/204
6 Start-Up
25ARGUS 28
automatically determine the physical access (BRI, U-interface, PRI or POTS). In this case, the ARGUS sets theBRI access to TE-mode (see “Setting the Access Mode” onpage 35).
In this case, the Access Mode menu will not open
and consequently functions such as BRI Monitor,BRI Recorder and Permanent Circuit will not beavailable.
If SHDSL, BRI, POTS or PRI is selected, theAccessMode (see Chap. 8 page 35) menu will open.
Initialization phase:
- Operation on a SHDSL access
The ARGUS displays theaccess mode and thevoltage on the SHDSL line.
- Operation on a BRI or U-interface access or operationas a BRI NT simulator:
Once the access and access mode parameters have beenselected or accepted, Layer 1 will be setup. While Layer 1 isbeing setup, the L1 LED above the display will blink. If theARGUS cannot setup Layer 1, it will display the message" No Net “.
When the ARGUS is operated on a U-interface access, itcan take up to 2.5 minutes to activate Layer 1.
MarkedAccess mode
scrollfurther
Return tothe Access
Name of the menu
The ARGUS acceptsthe - with a→ marked-Access Mode.The ARGUS will thenstart the
List iscontinued
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
26/204
6 Start-Up
26 ARGUS 28
As soon as Layer 1 is successfully setup, LED L1 will lightcontinuously.
Once Layer 2 has been setup LED L2 will light.
If both modes (P-P / P-MP) are found when Layer2 on the D-channel is checked, the mode must beselected manually (see Page 35).
If everything has been correctly detected, the ARGUS willdisplay the access type and mode found. Additionally, aqualitative assessment of the level will be displayed.
The ARGUS will automatically determine the protocol (inboth TE and NT mode) or use the protocol selected in theConfiguration/ISDN menu (see on page 163 “Configuration:ISDN”) . On a bilingual access, the ARGUS will use theDSS1 protocol.
LED L3 will light after the ARGUS has setup Layer 3.At the same time the ARGUS will start the B-channel test.The results will be displayed on the ARGUS. If an erroroccurs in the B-channel test (e.g. access is not plugged-in),
the ARGUS will - depending on the class of error - eitherrepeat the initialization or show an error message ((seepage 202 ARGUS Error Messages)).
The ARGUS will then idle in the Status display.
The ARGUS displays thetype of access (BRI), theavailability of the B-channels(B12), a level evaluation(OK),the access mode (TEs), thebus configuration (P-MP)and the protocol (DSS1).Press the torepeat the B-channel test.
The ARGUS in its Mainmenu
Status display example:
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
27/204
6 Start-Up
27ARGUS 28
The test found that it is a BRI multiple device access usingthe DSS1 protocol.
Shown on the second line in the display:The availability of the B-channels:B12 both channels are availableB1- only B-channel 1 is availableB-2- only B-channel 2 is availableB-- no B-channel available
If only one B-channel is available, this can have animpact on the service check and the testing of thesupplementary services.
Level evaluation only on a BRI access:OK the level is in order> the level is too high-- no level
Shown on the third line in the display:Access Mode:NTs = NT Simulation Slave ModeNTm = NT Simulation Master ModeTEs = TE Simulation Slave ModeTEm = TE Simulation Master Mode(see page 165 Clock mode)
Bus configuration:P-P: Point-to-PointP-MP: Point-to-Multipoint
It must be mentioned again, that the ARGUS onlydetermines the general bus status once when switched onor when the ARGUS first connected.On the other hand, the status of the protocol stacks for Layer1, 2 and 3 will be continually monitored and displayed.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
28/204
6 Start-Up
28 ARGUS 28
- Operation on a PRI access
As soon as Layer 1 is setup, LED L1 will light continuously.The ARGUS will automatically determine and display,whether or not the PRI access uses CRC4-monitoring.CRC4 monitoring can be switched on or off manually ((see
page 167 CRC4 mode)).
The ARGUS will begin the automatic detection of the accessconfiguration. After Layer 2 is setup, the L2 LED will alsolight.The ARGUS will, regardless of the mode of operation (TE orNT mode), determine the D-channel protocol and attempt tosetup Layer 3.
During this phase, the
ARGUS displays the A bit ofthe remote side. Protocoldetection is only possiblewhen the A bit is not set (+).Afterwards, the B-channel
test will be started.
With the B-channel test, the ARGUS checks the availabilityof all 30 B-channels by placing an outgoing call on each B-channel one after the other. If the call can be setup, it isassumed that the B-channels are available from both ends.
If the connection is rejected with Cause 44 (see AppendixB), the B-channel will be assumed to be only available forincoming calls.
If the connection is rejected for any other cause, the B-channel will be identified as unavailable. In the case of acause, which indicates that the B-channel is occupied, theconnection will be tried up to two times and, if a connectioncan still not be setup, it will then be marked as unavailable.
Displayed in the first line:Type of access: PRI
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
29/204
6 Start-Up
29ARGUS 28
Displayed in the second line:Available B-channels: The light squares represent the
available B-channels ordered in twoblocks of 15. The upper row ofsquares represent the B-channels thatare available for outgoing connections,the lower row represents those thatcan be used for incoming calls.left: B-channel 1right: B-channel 30
Displayed in the third line:
Operation mode: NTs = NT Simulation Slave Mode(see page 165 Clock mode)
NTm = NT Simulation Master ModeTEs = TE Simulation Slave ModeTEm = TE Simulation Master Mode
Layer 1 mode: With (CRC) and without CRC4(NoCRC)
D-channel protocol: Auto, 1TR6, DSS1, none,BILINGUAL, CorNet-NQ
CorNetN , CorNetT, QSIG or VN4
Test sample: The test found that it is a PRIaccess using CRC4-monitoring and the DSS1protocol. All 30 B-channelsare available and can beused for outgoing oralternating connections.
The B-channel test cannotdistinguish between alternating and exclusively "outgoing"B-channels.
The ARGUS is in the NT-Simulation Master modeand is connected to aterminal using the DSS1 D-channel protocol without
CRC4-monitoring.B-channel 11 is notavailable.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
30/204
6 Start-Up
30 ARGUS 28
The first 10 B-channels areconfigured in the exchangeas incoming channels only(seen from the viewpoint ofthe terminal), while B11-B30can be used for outgoing oralternating connections.
The ARGUS is not properlyconnected (e.g. wrongcabling) or the network is notin order.
- Operation on a POTS access
The ARGUS displays theaccess type (POTS) and theline voltage when idle.
ARGUS - Main menu
In the Main menu, you can scroll through the availablemenus with the key:
Status display
Main Menu
Repeat B-channel test
scrollfurther.
Return toStatus display
The ARGUS opensthe - marked with a→-
MarkedMenu The list
continues
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
31/204
6 Start-Up
31ARGUS 28
With the < >, you can open the menu currently marked withthe → (in the example Single Tests).
SHDSLaccess
PRI access BRI access
POTSaccess
Single Tests Single Tests Single Tests Single Tests
Test Manager Test Manager Test Manager _______
Automat.Tests Automat.Tests Automat.Tests Automat.Tests
________ ________ Level
Measuring
Level
Measuring
________ L1 Status L1 Status _______
Configuration Configuration Configuration Configuration
Access Access Access AccessAccu servicing Accu servicing Accu servicing Accu servicing
U-interface X.21 or V.35
Single Tests Single Tests
Test Manager ________ Automat.Tests Automat.Tests
Level Measuring ________
Configuration Configuration
Access Access
Accu servicing Accu servicing
Name of theopened menu
scrollfurther.
Return topreviously shown
Display
The ARGUS opensthe type of function/
submenu marked with→ .
List iscontinued
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
32/204
6 Start-Up
32 ARGUS 28
Using the numeric keys to start a function:
Using the digit keys, you can start important ARGUSfunctions directly, regardless of the currently active menulevel.
SHDSL access:Numeric key 6 Start Test ManagerNumeric key 7 Open Speed-Dialing MemoryNumeric key 9 Start Bit Error Rate Test (BERT)
BRI access or PRI access:Numeric key 2 Start Service checkNumeric key 3 Start Supplemental Service TestNumeric key 4 Start Auto. TestNumeric key 6 Start Test ManagerNumeric key 7 Open Speed-Dialing MemoryNumeric key 8 Trace ON/OFFNumeric key 9 Start Bit Error Rate Test (BERT)
If a function is called where the ARGUS expects theentry of a digit, pressing a number key will beinterpreted as the expected input.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
33/204
7 Setting the type of access
33ARGUS 28
7 Setting the type of access
If the parameters displayed at power on are not accepted,the Access menu will open automatically.However, you can also open the Access menu at any timefrom the Main menu.In the Access menu, the user must select the type ofphysical access to which the ARGUS is actually connected.When the ARGUS is restarted, the settings used last will besuggested as the default.
If you press the softkey, the B-channel test
will be repeated.Open theMain menu
Using the < ↓ > select theAccess menu
The Access menu will open
Using the select thetype of access(e.g. SHDSL)
Confirm the access
The Access Mode menu willopen automatically.
The following applies for all displays: If you press the< > , the ARGUS will return to the previous display.
IfAutomatic is selected, a fully-automatic sequence will bestarted: The ARGUS will automatically determine the type ofinterface (BRI, PRI or POTS) and set the access to TE-mode.
Status display
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
34/204
7 Setting the type of access
34 ARGUS 28
7.1 Operation on a U-interface access
To test a U-interface access, the ARGUS is connected viathe U-interface adapter to the U-interface access.
As the physical access,select BRI in the Accessmenu.
The Access Mode menu willopen automatically: In thecase of a U-interfaceaccess, you must choose -as Access Mode - TEAutomatic, TE P-P, TE P-MPor permanent circuit.
onnection to a U-interface access:
What the LED on the U-Interface Adapter indicates:
LED is red: not activated, e.g. cable notconnected correctly
LED flashing (green/red) slowly - once per second: U-interface is activated; the ARGUS, however, is deactivatedLED flashing (green/red) quickly - twice per second:ARGUS is activated, U-interface is deactivatedLED is green: everything correct
Connectionto Line jack
Connection tothe
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
35/204
8 Setting the Access Mode
35ARGUS 28
8 Setting the Access Mode
The Access Mode menu isnot selectable from the Mainmenu.It opens automatically oncethe physical access isselected in the Access menu.
8.1 Operation on a BRI, U-Interface or PRI
8.1.1 TE-Simulation mode
TE automatic
On a BRI or U-interface access, the ARGUS willautomatically determined the D-channel Layer 2 mode(PP or P-MP). If the ARGUS determines that the accesssupports both modes, the following Configuration menuwill open:
Using the , selectL2 mode.
Confirm the selectedL2mode
The ARGUS will returnto the Main menu.
TE P-P or TE P-MP
Afterwards, the access and the protocol stack will beinitializedin accordance with the selected setting.When the ARGUS finds a PRI access, it will enter P-Pmode.The ARGUS will then jump to the Main menu.
8.1.2 NT-Simulation mode
NT P-P or NT P-MP
Afterwards, the access and the protocol stack will beinitialized
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
36/204
8 Setting the Access Mode
36 ARGUS 28
in accordance with the selected setting.When the ARGUS finds a PRI access, it will enter P-Pmode.The ARGUS will then jump to the Main menu.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
37/204
8 Setting the Access Mode
37ARGUS 28
8.1.3 Permanent circuit
With the , selectPermanent switch .
Access modeconfirmed
The ARGUS is now switchedtoPermanent circuit mode (thedisplay shows LL [LeasedLine]) and will open theStatus display.
Besides dial-up connections to any subscriber, ISDN alsosupports the use of permanent circuits switched to a specificremote location.
These permanent circuits are available after setting upLayer 1, in other words after synchronizing both terminals byexchanging HDLC-frames.
The location where the clock is generated can be selected(see page 165 Clock mode).
As a quick test of a permanent circuit, you can simply callthe opposite end using a selected B-channel.However, for a more revealing test of a permanent circuit,you should perform a bit error rate test.Both ends of the permanent circuit must use the samechannel.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
38/204
8 Setting the Access Mode
38 ARGUS 28
Telephony on permanent circuits
The function can be started with the -Key or via thePhone / connec. function in theSingle tests menu (seeChap. 12 page 125).After the B-channel for the permanent circuit is selected, thetelephone connection will be setup automatically.
The ARGUS displays the B-channel used (e.g. B01) andthe duration of thepermanent circuit.Using the < TM > softkey:Start Test Manager(seeChap. 13 page 137)
Terminate permanentcircuit
The ARGUS will open theStatus display
BERT on permanent circuits
A number of variations are possible in testing the permanentcircuit with the bit error rate test.
In the simplest case, a B-channel loop will be set up at theremote end.Start the BERT from theSingle tests menu / Bit error testsubmenu / BERT start (see page 94 Start BERT). Afterselection of the channel to be tested (B-channel or D-channel), the ARGUS will send the test pattern, receive itback and evaluate it accordingly.
The displays and operation are, in largest part, similar tothose of a BERT on a dial-up connection (see page 92 Biterror test), you simply need not enter call numbers or selecta service.
In the case of a BRI access in end-to-end mode (on page 92“Bit error test”and on page 100 “BERT wait”), it is alsopossible to run a BERT in the D-channel.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
39/204
8 Setting the Access Mode
39ARGUS 28
In this case, the channel select window will open:On a BRI access:
With the < ↓ > , select thechannel
Selecting a B-channel (e.g64k)
Enter the B-channel on thekeypad. If you enter an *, theARGUS will choose any B-channel that is free.
Confirm the selected channeland start the BERT.
The ARGUS will display- the bit pattern (e.g. 2^15)- the channel / bit rate used(e.g. B02/1984k)
- the remaining test time in Hours: Minutes: Seconds(e.g. 00:24:12)
- the bit errors that haveoccurred (e.g. 2)- Synchronicity of the
bit pattern (synchron)- the LOS-counter (e.g. 0).
Use the softkey toinsert artificial bit errors to testthe reliability of the BERT.Use the softkey to StartTest Manager. see “TestManager” on page 137
Once it is over, the ARGUS will display the results of theBERT (see “Start BERT” on page 94).
BERTstop
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
40/204
8 Setting the Access Mode
40 ARGUS 28
On a PRI access:
In the case of a PRI access in end-to-end mode (see “Biterror test” on page 92and see “Start BERT” on page 94), aBERT can be run- in the D-channel
- in all B-channels- in all B-channels and in the D-channel (framed)- in selected B-channels- in all channels and time slot 0 (unframed).
The channel select mask will open.In this mask you can chose from 3 predefined channelpatterns:- MegaBERT framed (default: all B-channels and the
D-channel)- MegaBERT unfr. (default: all B-channels, D-channel
and time slice 0)- B-chann. (1..30) (default: all B-channels)
All three channel patterns can be changed as needed andsaved under any name desired.
When the parameters (see Page 187) are reset,the channel patterns are reset to their defaultsettings.
With the < ↓ > select thechannel pattern (e.g. B-chann.(1..30)
To edit the channel pattern
Edit the channel patternsee Page 41 Editing theselected channel pattern
-Key
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
41/204
8 Setting the Access Mode
41ARGUS 28
If desired, enter the new namefor the pattern to be storedunder. When the right softkeyis pressed it assumes adifferent meaning and thusinfluences the entries madefrom the keypad (letters ordigits) see Page 180.
Store channel pattern
Start BERT with selectedchannel pattern
When "Selection“ is chosen,the BERT will start as soon asa channel pattern is entered.
Setting the channel pattern
BERT start
Editing the selected channel pattern:
In the channel selection window, the light squares representtime slot 0 (upper display line left square), the D-channel
-Key
Start BERT
Start BERT
-Key
TimeSlot 0
D-
Available B-channels ordered in two
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
42/204
8 Setting the Access Mode
42 ARGUS 28
(the left square on the lower display line) and the B-channels are assigned to the two blocks of 15 (upper displayline B-channels 1 to 15, lower display line channels 16 to30). The selected channels are indicated in the upper row bymarked squares. The marked squares in the lower rowindicate the current position of the cursor.
The cursor is moved with the arrow keys:↓ -Key moves the cursor one position to the left↑ -Key moves the cursor one position to the right.The channels can also be marked with the cursor directlyusing the numerical keypad: If you enter the digits 08, thecursor will jump to B-channel 8. If you enter *, the cursor willmove to time slot 0 and the entry of the # will move thecursor to the D-channel.
Time slot 0 can only be selected, when all otherchannels (all B-channels and the D-channel) areselected (i.e are free).
If the right softkey shows , pressing the softkey < ALL >will select all B-channels and the D-channel (Mega BERTframed). When the right softkey shows , pressing thesoftkey < ALL > will deselect the currently selected channels.
Channel selection examples:
No B-channel has beenselected; the cursor is sittingat B-channel 10 (markedsquare in the lower row). TheARGUS shows that thechannel marked by the cursorhas not yet been selected(B10:- ) and is free (free ).
With < ON >, select thechannel
B-channel 10 is selected(marked square in the upperrow)
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
43/204
8 Setting the Access Mode
43ARGUS 28
No B-channel has beenselected; the cursor is sittingat B-channel 10.
With < ALL >, select allchannels except time slot 0.
The cursor is sitting at timeslot 0.
With < ON >, select themarked channel (time slot 0).
Time slot 0 is selected(TS0:+) and is still marked by
the cursor (both squares aremarked)
Channels 5 to 8 wereindividually marked with thecursor and selected with; the cursor is at B-
channel 8.
Channels 5 to 8 and 20 to 23have been selected.The cursor is at channel 24.Channel 24 cannot beselected, since it is busy.
Mega
BERTframed
Mega BERTunframed
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
44/204
8 Setting the Access Mode
44 ARGUS 28
Loopbox with a permanent circuit
A loopbox can be setup for the permanent circuit byselecting in theSingle tests menu / Bit error test submenu / the B-channel LOOP (see “B-channel loop” on page 101).
The Channel select windowwill open.
When "B-channel" isselected, the Loopbox issetup for both B-channels.If "All framed" is selected, notonly both B-channels but theD-channel will also belooped.
Activate loopbox
The ARGUS will display thechannel used (B01) and theamount of time (h:min:sec)that the Loopbox has been
active.
If B-channel is selected,the loopbox can be setup forB-channel 1 to 30.
If All framed is selected,not only both B-channels butthe D-channel will also belooped.If All unframed isselected, not only the B-channels and the D-channelbut also time slot 0 will belooped.
On a BRI access:
Loopboxstop
On a PRI access:
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
45/204
8 Setting the Access Mode
45ARGUS 28
Switching from permanent circuit mode
Using the < ↓ >, select theAccess menu.
The Access menu will open
Using the < ↓ >, select thedesired access.
The Access mode menu willopen.
Using the < ↓ > , select thedesired Access mode (e.g.TE P-MP).
Confirm the selected accessmode
The ARGUS will open theStatus display
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
46/204
8 Setting the Access Mode
46 ARGUS 28
8.1.4 BRI/PRI Monitor
The ARGUS accepts all of the D-channel signals from theBRI or PRI access and sends these D-channel signals overthe serial interface to a PC, which must be running ARGUSWINplus or WINAnalyse. The bus and Layer 1 are not
influenced by the monitoring.
Monitoring a BRI access
Using the< ↓> , selectMonitor .
Confirm the selected accessmode
The ARGUS evaluates thelevel on the NT-side: OK, > (too high), _ (nolevel)(Monitoringnot yet active)
Start monitoringThe Trace LED lights.
The ARGUS displays thenumber of recorded signals(e.g. 25) and the recordingtime in h:min:sec.Select < ABORT > to stopmonitoring.
Listening-in on voice data
The B-channel select dialog
will open.Enter the B-channel. TheARGUS will switch thehandset to this B-channel. It isnow possible to listen to thevoice data (in the directionNetwork --> User).
Listening
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
47/204
8 Setting the Access Mode
47ARGUS 28
Simultaneous call display while monitoring a BRIaccess
While monitoring, the ARGUSwill search all of the D-channels signals sent for aSETUP. If a SETUP isdetected, the softkeywill be displayed.
Display the call parameters ofthe last SETUP received.
The ARGUS displays the calldirection (Net -> User), theservice (e.g. FaxG3), the ownnumber (e.g. 125670), thechannel used (e.g. B01) andthe destination number (e.g.02351 901729).
Display of other parameters:Sub-address (SUB),User-User-Info (UUI),DSP messages (ifexistent),Type of Number (T.O.N) ,
Numbering plan (NP).
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
48/204
8 Setting the Access Mode
48 ARGUS 28
Monitoring a PRI access:Same procedure as when monitoring a BRI access
ARGUS messages on a PRI access:As soon as a change occurs, the ARGUS will send a time-stamped report of the following alarms/states to the PC,which will evaluate them:
- Signal- FAS- CRC4det- A bit- AIS
The ARGUS will check the following values and countersevery second and, in the event of a change, will pass themon the PC:
- Sa5-bit (Rx)
- Sa6-bit (Rx)- E-bit- Ecnt- CRC Err.- Cod.Err.- Fram.Err.
Display of the L1 Status in PRI Monitor mode
The L1 status function is only available in PRI Monitor
mode.The Layer 1 alarms and messages are presented in severalwindows, which permit detailed statements regarding thestate of the PRI access and the transmission line (Forfurther information, see the CCITT/ITU guidelines G.703 andG.704).When the function is started, it will first automatically openthe “L1 status TE” function, which shows the “TE-sideparameter”. For a comprehensive explanation of thedisplayed information: see “The L1 status of a PRI access”on page 157.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
49/204
8 Setting the Access Mode
49ARGUS 28
The ARGUS is in PRI Monitormode(Monitoring isnot active)
With the< ↓ >, selectL1 status .
Display of the "TE-sideparameters"Use the ↓ -Key to scrollthrough the display.
Press < NT > to switch to the“L1 status NT” function; the“NT-side parameters” will bedisplayedPress to reset theHistory function and allcounters.Press < ABORT > to quit thefunction and return to themenu list.
8.1.5 BRI/ PRI Recorder
In Recorder mode, the ARGUS passively monitors theconnected BRI or PRI access.The ARGUS records all of the D-channel signals sent inboth directions without affecting the access or Layer 1.Unlike in the Monitor mode, the recorded D-channel signals
will be saved in the ARGUS’s internal Flash memory and notsent to a PC.The storage is organized as a ring buffer, i.e. as soon as theFlash memory is full, the ARGUS will automatically overwritethe oldest data.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
50/204
8 Setting the Access Mode
50 ARGUS 28
Select BRI Recorder (or PRIRecorder on a PRI access).
Start the Recorder function.
The ARGUS is now inRecorder mode (Monitoring isnot yet active!) and will checkthe levels on the NT and TEsides of the BRI access.Displayed in the second line:Level on the NT-side (> too high, OK, ___ nolevel), level on TE-side (> too high, OK, ___ no level)
Recording started(The Trace LED flashes)
The display shows thenumber of signals receivedand the duration of therecording in
hours:minutes:seconds.Using , switch thespeech path onto a B-channel. First the B-channelselect dialog will open. Afterselecting a B-channel, it willbe possible to listen to thevoice data (in the directionNetwork ----> User) on thischannel.
Parallel call display while recording
The ARGUS searches all of the D-channel signals sent for aSETUP. If a SETUP is detected, the softkey will bedisplayed.Use to display the call parameters of the lastSETUP received. (see page 47 Simultaneous call displaywhile monitoring a BRI access)
Example on a BRI access:
Quitting the activerecording function. TheARGUS is then in the“Recorder” mode.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
51/204
8 Setting the Access Mode
51ARGUS 28
Operation on a PRI access:
Use to switch theARGUS speech path onto aB-channel. First the B-channel select dialog willopen. After selecting a B-channel, it will be possible tolisten to the voice data (in thedirection Network ----> User)on this channel.Use < ABORT > to stop theactive recording function. TheARGUS is then in the“Recorder” mode.
The ARGUS saves a timestamped report of any changes inthe following alarms/states:
- Signal- FAS- CRC4det- A bit
- AISThe ARGUS will check the following values and countersevery second and, in the event of a change, will save them:
- Sa5-Bit (Rx) / (Tx)- Sa6-Bit (Rx) / (TX)- E-Bit- Ecnt- CRC Err.- CRC rel.
- Cod.Err.- Cod.rel- Frm.Err.
8.1.5.1 Administration of the recorded data
In the Recorder mode, several functions are available for
Time Slot 16
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
52/204
8 Setting the Access Mode
52 ARGUS 28
administration of the data saved in the Flash memory:- PC load all- PC load session- Reset Flash- Info Flash
PC load all
With thePC load all function, all of the contents of the Flashmemory will be downloaded via the serial interface to thePC, which must be running either WINplus or WINanalyse.
The ARGUS is in "Recorder"mode(Recording not active)
Using < ↓ >, selectPC load all .
Start charging the
accumulators
Select < ABORT > to stop thetransfer.
After the data has beensuccessfully transferred to the
PC, the Flash memorycontents can be deleted.Select < YES > to delete theFlash memory contents.Select < ABORT > to quit andnot delete the Flash memorycontents.
PC load session
In the ARGUS, the storage in the internal Flash is organized
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
53/204
8 Setting the Access Mode
53ARGUS 28
as a ring buffer, which can hold the data from a series ofseveral sessions (i.e. independent trace recordings). At thestart of each session, the date and time will be written in thering buffer.ThePC load session function transfers all of the data session-by-session to the PC on which either WINplus orWINanalyse must be running. The time and date that thesession was started will be displayed in WINplus/ WINanalyse.
The ARGUS is in "Recorder"mode(Recording not active)
Using < ↓ > , select PC loadsession .
The loading of theindividual sessions willstart.
Select < ABORT > to stop thetransfer.
Multiple sessions can betransferred to the PC oneafter the other.Press to loadthe next session to the PC.
After the data has beensuccessfully transferred to thePC, the Flash memorycontents can be deleted.Select < YES > to delete theFlash memory contents.Select < ABORT > to quit andnot delete the Flash memorycontents.
Internal decoding
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
54/204
8 Setting the Access Mode
54 ARGUS 28
The ARGUS will decode the D-channel data stored in theFlash memory:
Using the < ↓ >, selectInternal decod. .
Display the signals sent to thenetwork ("
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
55/204
8 Setting the Access Mode
55ARGUS 28
Reset Flash
The Reset Flash function will delete the entire contents ofthe data Flash memory.
The ARGUS is in "Recorder"mode(Recording not active)
With the < ↓ >, select ResetFlash .
Select < YES > to delete theFlash memory contents.The procedure can takeseveral seconds. The ARGUSwill show the progress of thedeletion as the percentagedone.It is not possible to stop theprocess of deletion!
Use < ABORT > to return to theprevious menu; the contentsof the Flash memory willnotbe deleted.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
56/204
8 Setting the Access Mode
56 ARGUS 28
8.1 Operation on a POTS (analog) access
8.1.1 POTS terminal
Using the< ↓ >, selectPOTS interface .
Confirm the access
Using the< ↓ >, selectPOTS terminal .
The Argus behaves like aPOTS (analog) terminal.
The ARGUS will return to theMain menu.
8.1.2 POTS monitor
Essentially, the POTS (analog) monitor provides a highimpedance tap that does not influence the interface.You can listen to the line with the integrated handsetwithout having the ARGUS send on or otherwiseinfluence the interface.
The ARGUS displays thevoltage level on the line whenit is "on hook“ (not busy).
Start monitoring
The ARGUS displays thevoltage (when "off hook"), thenumber of the caller (whenCLIP is supported) and theDTMF characters dialed byboth telephone subscribersand the SMSs received(optional).Any received DTMF-characters will be appendedto the line, which will shift leftfor each character once it is.
full.
Monitoringstop
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
57/204
8 Setting the Access Mode
57ARGUS 28
An incoming call will be signalled acoustically.Press the < ↓ > -Key to display additional information, ifavailable on the access (e.g. advice of charges).Press < DEL > to clear the display.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
58/204
9 Operation on an X.21 or V.35 Access
58 ARGUS 28
9 Operation on an X.21 or V.35 Access
The ARGUS will perform a bit error test on the X.21 or V.35access in accordance with the ITU guidelines G.821 andG.826.
Besides the measurement results, the ARGUS will alsodisplay the X.21/V.35 data rate.
Use the adapter cable to connect the ARGUS to the X.21/ V.35 network.
Use the < ↓ > to select X.21 .
X.21 Interface Adapter
Connection to Connection to X.21networkor X.21 standard
Example - on an X.21
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
59/204
9 Operation on an X.21 or V.35 Access
59ARGUS 28
9.1 Start BERT
The ARGUS will detect the clock of the X.21/V.35permanent circuit, calculate the data rate and thenautomatically search for the channels used. On these
channels, the ARGUS will send the test pattern (see page172 Bit pattern BRI/U) selected, receive it again andevaluate it in accordance with the ITU guidelines G.821 andG.826 (loopbox required at the remote end).
Press to start theBERT
Displays the bit pattern(2^15), the X.21/V.35 datarate (1984 kBit ), theremaining test duration inh:min:sec (15:45:42), thenumber of bit errors that haveoccurred (3), thesynchronicity of the bit pattern(synchron) and the LOS-counter.
Press to restart thebit error test; the counters(e.g. number of bit errors) willbe reset.Press to inject an“artificially generated” biterror, which can demonstratethe reliability of themeasurements in particularwhen running end-to-endtests.
When a bit error is detected, this will be signaledby a brief alarm (if the alarm is enabled); in theevent that the synchronisation is lost, a constantalarm will sound.The alarm bells can be switched off.(see page 184 Alarm bell).
The measurement time for the BERT can be set with theBERT config. function (see page 171 BERT - duration).
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
60/204
9 Operation on an X.21 or V.35 Access
60 ARGUS 28
9.1.1 Display the test results
The ARGUS will display the following test resultsautomatically after the test is completed:- Bit pattern and X.21/V.35 data rate
- Transferred data in kBits (in the example 10309 kBits)- Number of the bit errors that have occurred (in the example10)- Bit error rate (in the example 9.7·10-7 (= 0.00000097))The evaluation of the results depends on the error thresholdthat you set ((see page 171 Error level)).OK = bit error rate is less than the error threshold (set by theuser) and NO = bit error rate is above the error threshold.
Press < MORE > to displayother characteristic values(in accordance with ITU-TG.821and G.826) All valuesare given in percentages.The ARGUS evaluateswhether the test resultssatisfy the limits specified inthe CCITT G.821/G.826under consideration of thedefined hypotheticalreference connection HRX(display shows OK or NO).(see page 92 Bit error test)Press < MENU > to return tothe BERT menu.
9.1.2 Saving the test results in the ARGUS
Display of the results
Press the -Key
Press to have theARGUS save the results.(see page 97 BERT - saving)
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
61/204
9 Operation on an X.21 or V.35 Access
61ARGUS 28
9.2 BERT wait
In this mode, the BERT will wait for the BERT at the remoteend which is necessary for an end-to-end test:see “BERT wait” on page 100.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
62/204
9 Operation on an X.21 or V.35 Access
62 ARGUS 28
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
63/204
10 SHDSL Tests
63ARGUS 28
10 SHDSL Tests
The ARGUS supports a variety of access types.Depending on the access mode selected (and the protocol),the following single tests are supported:
The ARGUS displays the results during the test.
If desired, the ARGUS will save the test results (even if thetest is aborted) together with the date and time in its internalFlash memory.
The saved results can later be sent to a PC or viewed on thedisplay.
Access mode Single Tests
STU-C 2-wireThe ARGUS simulates thenetwork side of the SHDSLconnection(central office)
- SHDSL test- Bit error test- Connection
STU-R 2-wire/PRIConnection of the ARGUS to
the SHDSL access (using theDSL jack) or to the PRI network(e.g. connection to a PBXsystem using the Line jack).The ARGUS replaces theSHDSL modem.
- SHDSL test
STU-R 2-wireThe ARGUS simulates the userside of the SHDSL connection(remote).
- SHDSL test- Bit error test- Connection
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
64/204
10 SHDSL Tests
64 ARGUS 28
10.1 - SHDSL Line Test
The ARGUS is connected directly to the SHDSL access viathe SHDSL 2-wire connection cable.
Setting the access mode:
In the Main menu, use the< ↓ > to select the Accessmenu.
Open the Access menu
Using the < ↓ >, selectSHDSL .
The Access mode menu willopen automatically.
Black 2-wireconnection cableRJ45 - RJ11 cable
JackDSL
SHDSLAccess
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
65/204
10 SHDSL Tests
65ARGUS 28
Use < ↓ > to select thedesired Access mode (STU-C 2-wire , STU-R 2-wire orSTU-R/PRI) .
The ARGUS will open theStatus display
The ARGUS will display theselected access mode (in theexample: STU-R 2-wire) andthe supply voltage on theSHDSL line.
If the ARGUS is not yet active, you must firstselect a test and start it.(see the next pages).
If you press the < >, the ARGUS will return to theprevious display.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
66/204
10 SHDSL Tests
66 ARGUS 28
In the SHDSL line test, the ARGUS first sets up a SHDSLconnection and then determines all the relevantperformance parameters.The ARGUS displays the performance parameters duringthe test and saves them in the internal FLASH memorywhen the test is finished or aborted.
Parameter settings:The following parameters can be configured for the test (seePage 161):SHDSL parameter : Spectrum, Clock/framing, Channelselection, Power back off and EOC using
The ARGUSStatus display
Press Menu to open theMain menu or to begin the SHDSL linetest
Using the < ↓ > , selectthe Single tests menu.
Open the Single testsmenu
Using the< ↓ > , selectSHDSL test .
Initialisation of theSHDSL software
The ARGUSsynchronises itself withthe remote end (in theexample, with STU-C).
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
67/204
10 SHDSL Tests
67ARGUS 28
The ARGUS will setup aSHDSL connection anddisplay the associated"states“ and bit rate.
In the event ofsynchronisation problems,"no. comm. mode" will bedisplayed.In this case, check theSHDSL parameters in regardto synchronisation with theremote end (see Page 161)Press < ABORT > to cancelthe setup of the connection.
The SHDSL connection issetup.
Use the : toscroll through. The ARGUSdisplays the bit rate, the Band Z-channels, the rep.count and the voltage on theSHDSL line.Press < TM > to open theTest Manager; you can thenstart a bit error test or setup aconnection, see “TestManager” on page 137
Display of the performanceparameters
etc. ......
-Key
-Key
-Key
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
68/204
10 SHDSL Tests
68 ARGUS 28
Display of the performance parameters
The ARGUS displays the SHDSL line's performanceparameters for the remote end (R) and the central office end(C) (see "SHDSL Span" in the illustration below) and foreach SHDSL line segment (see "SHDSL Segment" in theillustration below); the parameter "EOC using" must be setto "on“ see Page 162.
SNR Margin
This value is given in dB andshows how much additionalnoise the transmission couldtake before the BER (BitError Rate) would exceed 10-7.
Press < > to view theparameters of the next linesegment. The parametersshown are those for the linesegment currently indicatedin the top line.Press < > to scroll back.
Use the -Key to scrollthrough the performanceparameters.Use the < TM > softkey to
start the Test Manager (Page137).
STU-R
Network side =NCustomer side =C
N C
Intermediate repeaters 1 to a maximum
N C N C N C
STU-C
SHDSLSegment SHDSLSegment SHDSLSegment
SHDSL Span
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
69/204
10 SHDSL Tests
69ARGUS 28
Attenuation (dB)Line attenuation in dB
Power (dBm)power based on 1mW
CRC CountCyclic Redundancy CheckCounter
Number of CRC6 checksumerrors
Loss of Sync DefectWord secondsNumber of faulty sync wordsper second
Errored Second Count(ES Count)Number of errored seconds(seconds with CRC errors)
Several Error SecondCount (SES Count)Number of seconds withmore than 50 CRC errors
-Key
-Key
-Key
-Key
-Key
-Key
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
70/204
10 SHDSL Tests
70 ARGUS 28
Unavailable Second Count(US count)Number of seconds in whichno SHDSL connection wasavailable.
Press < > to scroll to thedisplay of "SHDSL line 1"
Press to have theARGUS save the result in thefirst available record in theFLASH memory (see“Automatic Tests” on page142).
Storing the result
Using the numeric keys enterthe name under which theresult should be saved(Default: AMP_1, AMP_2....or the call number of theaccess under test if thenumber has been enteredinto the speed-dialingmemory)Use the softkey on theright to shift the keypad (thesoftkey on the right assumesa different meaning whenpressed):< 12>ab > : entry of thedigits 0 to 9 plus * and #< ab>AB > : entry of thelowercase characters and @, /,- and . (e.g. to enter a "c“press the "2" on the keypadthree times)< AB>12 > : entry of theuppercase characters and@, /,- and .
Use the ↑ ,↓ -Keys to movethe cursor to the right or left
-Key
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
71/204
10 SHDSL Tests
71ARGUS 28
Press < DEL > to delete thedigit before the cursor.
-Key: Store result< ABORT >: Result not stored
Press to start a newtest without reinitialising thesoftware and setting up theSHDSL connection again.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
72/204
10 SHDSL Tests
72 ARGUS 28
10.2 Displaying the stored results(see “Automatic Tests” on page 142)
In the Main menu, use the
<↓> to select Automatictests .
Use the < ↓ > -Key to selectthe record (e.g. AMP_2)holding the saved testresults.
Use the < ↓ > to selectDisplay result .
Display the test resultsUse the < ↓ > to scroll.
Display the performanceparameters
Close the results display.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
73/204
10 SHDSL Tests
73ARGUS 28
10.3 Bit error test
The bit error rate test (BERT = Bit Error Rate Test) servesto check the transmission quality of the access circuit.In the bit error test, the ARGUS sets up a SHDSL
connection to a remote tester or places a call to itself, sendsa standardized (quasi-) random number string andcompares the received data with that which was sent.During the test, the ARGUS counts the bit errors and afterthe test is done it calculates the bit error rate and otherparameters in accordance with the ITU guidelines G.821and G.826.Normally, the bit error rate during a 1 minute test should beless than 10-7.
However, if the test shows a higher bit error rate, it shouldbe repeated with a measurement time of 15 minutes toincrease its statistical precision.
The BERT can be performed in different ways:
BERT with a loopbox
A loopbox (e.g., another member of the ARGUS familyof testers at the remote end) is required.
BERT end-to-end
This test requires a waiting remote tester such as anARGUS in theBERT wait mode . A bit pattern is sent tothis tester.
Independent of the received bit pattern, the remotetester uses the same algorithm to generate a bit-patternthat it sends back.
Therefore, both directions are tested independently.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
74/204
10 SHDSL Tests
74 ARGUS 28
10.3.1 BERT start
The following parameters are required for the BERT:- SHDSL parameter- BERT parameters:
Duration of the BERT (default setting = 1 minute)Error level : If the bit error rate is greater than theerror level value, the ARGUS will display a NO inthe test result. If the bit error rate is less than theerror level value, the ARGUS will display an OK(default setting 10-06 )HRX value in % (hypothetical reference connectionsee ITU-T G.821) (default setting = 15%)Bit pattern , which will be sent during the test
(default setting = 215-1)
The ARGUS in theStatus display
The ARGUS returns to theMain menu.
Press < ↓ > to selectSingle tests
Open the Single tests menu
Press < ↓ > to select theBit error test
Initialisation of the SHDSLsoftware(if the SHDSL connectionhas not already been setup)
The ARGUS synchronisesitself with the remote end (inthe example, with STU-C)and sets up the SHDSLconnection(if the SHDSL connectionhas not already been setup)
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
75/204
10 SHDSL Tests
75ARGUS 28
The ARGUS displays theavailable channels.
Selection of the B-channelsused in the BERT.
Start BERTAfter the ARGUS has setupthe connection andsynchronized the send andreceive directions, it willdisplay the bit pattern (e.g.2^15), the data rate (e.g.2312kB) , the remaining test
time in h:min:sec, thenumber of bit errors thathave occurred (e.g. 0), thesynchronicity of the bitpattern (synchronous orasynchronous) and the LOS-counter.
If you press < ERROR >, the ARGUS will generate anartificial bit error, which can be used to test the reliability of
the measurement (in particular for end-to-end tests).
Press < TM > to start the Test Manager (see “Test Manager”on page 137 )
Press < ABORT > to stop the BERT.
0 -Key: Restarts the bit error test. The test time and numberof bit errors will be reset.
When a bit error is detected, this will be signaledby a brief alarm; in the event that thesynchronisation is lost, a constant alarm will sound(see “Alarm bell” on page 184).
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
76/204
10 SHDSL Tests
76 ARGUS 28
The test results display:The bit pattern (e.g. 2^15),The data rate in kBits (e.g.2312 kB), the transferreddata in kBits (e.g. 10309 Kb)The number of bit errors(e.g.10),The bit error rate (e.g. 9.7E-07 = 9.7·10-7 = 0.00000097),The evaluation of the resultsdepends on the errorthreshold (OK).< MENU>: The ARGUSreturns to the BERT menu.
Display of other charac-teristic values (in accordancewith ITU-T G.821/G.826)All values are given inpercentages.The ARGUS evaluateswhether the test resultssatisfy the limits specified inthe CCITT G.821/G.826under consideration of thedefined hypothetical
reference connection (HRX).(see Page 96).↓ -Key: Scroll
BERT - saving the result
The ARGUS will save theresult in the first availablerecord in the FLASH memory
(see “Automatic Tests” onpage 142).
Save the test resultssee Page 70
-Key
-Key
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
77/204
10 SHDSL Tests
77ARGUS 28
Another test can be startedwithout reinitializing theSHDSL test software andsetting up the SHDSLconnection again.
Displaying the saved test resultssee “Displaying the stored results” on page 72
Note: kBit = Bit*1000 KBit = Bit* 1024
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
78/204
10 SHDSL Tests
78 ARGUS 28
10.3.2 BERT wait
In BERT wait mode, the ARGUS will wait for the BERT atthe remote end which is necessary for an end-to-end test:
In the Single tests menu,use the < ↓ > to selectBit error test .
Open the Bit error test menu
Using the < ↓ >, selectBERT wait .
Activate "BERT wait“
Using< ERROR > artificiallygenerate a bit error.Press < ABORT > to stop theBERT.
After the test period haselapsed, the ARGUS willdisplay the result of theBERT.
Press < TM > to start theTest Manager (Page 137)
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
79/204
10 SHDSL Tests
79ARGUS 28
10.3.3 B-channel loop
B-channel loop mode is required in order to run a bit errortest using a loopbox. All B-channels and Z-channels will belooped back.
Activate loopbox
The ARGUS will display theamount of time (h:min:sec)
that the loopbox has beenactive.
Loopboxstop
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
80/204
10 SHDSL Tests
80 ARGUS 28
10.4 Telephony on permanent circuits
To test a permanent circuit, you can simply call the oppositeend using a selected B-channel. Both ends of thepermanent circuit must use the same B-channel.
The SHDSL parameter channel selection (seePage 162 ) may only be set to "auto “, when theremote end sets the data rate.
A connection can only be setup at data rates lessthan or equal to 2048 kBits, i.e. the channelselection parameter may be set to a maximum of32 B-channels.
Use < ↓ > to selectPhone / connec. in theSingle test menu
or press the -Key.
Use the ↓ ,↑ - keys to scrollthrough the availablechannels and to select one .
Setup a permanent switch
The ARGUS displays the B-channel used (e.g. B01) andthe duration of thepermanent circuit.Use the < TM > softkey tostart the Test Manager(see “Test Manager” on page
137)Terminate permanentcircuit
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
81/204
11 Single Tests
81ARGUS 28
11 Single Tests
11.1 Test the Supplementary Services
The ARGUS checks whether the access under test supportssupplementary services in 1TR6 or DSS1 protocol.
11.1.1 Suppl. Services Test on 1TR6
(only BRI or U-Interface)
Using the < ↓ > in the Mainmenu, select the Singletests menu.
The Single tests menuopens
Using the < ↓ > , selectSupp.serv.test .
Start test
The test is running.
The test results aredisplayed automatically:+ = suppl. servicesupported- = suppl. service notsupportedUse < ↓ > to scroll through
the test results
Sperre Blocking enabled for outgoing calls
AWS1 Call forwarding type 1 enabled (continuous)
AWS2 Call forwarding type 2 enabled (case by case)
AnschlussGBG
Access belongs to a Closed Users Group
The ARGUS will return tothe
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
82/204
11 Single Tests
82 ARGUS 28
Geb.anzeige Advice of charge
Rufnummern-Id
Setup call number identifier - againstmalicious calls
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
83/204
11 Single Tests
83ARGUS 28
11.1.2 Suppl.service interrogation in DSS1
In the Single tests menu,using the < ↓ >, selectSupp.serv.test .
Open the enter Numbersdialogue
Use the keypad to enter the"Own number" (the numberof the access under test)(see “Saving Call Numbers”on page 185.). The ARGUSwill test the availability of thesupplementary service (in
part by placing a call toitself).
Using the < ↓ >, select theservice which should beused for the supplementaryservices test.
Confirm the service.
Enter the B-channel on thekeypad. By default, thechannel last used will besuggested. If you enter an *,the ARGUS will choose anyB-channel that is free.
Confirm the B-channel
Use the < ↓ > to select thesupplementary service (e.g.TP) that you want theARGUS to check whether itis supported on the accessunder test.
Start test
The ARGUS will display theresults of the test once it isdone:
+ = suppl. service supported- = suppl. service not supportedUse the < ↓ > to scroll through the test results.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
84/204
11 Single Tests
84 ARGUS 28
If you press the < > , the ARGUS will return to theprevious display (this applies for all displays).
Test Comments
TP The ARGUS tests theTP (Terminal Portability)supplementary service by making a self call.
HOLD The ARGUS tests the HOLD supplementaryservice by making a self call.
CLIP
(CLIP, CLIR, COLP, COLR )
In this test, the ARGUS checks whether the 4supplementary services CLIP ,CLIR , COLP andCOLR are supported. To do so, the ARGUSwill setup as many as three calls to itself.CLIP : Will the calling subscriber's number be
displayed at the called subscriber?(t = CLIP temporarily availablep = CLIP permanently available)CLIR: Will the display of the callingsubscriber's number at the called subscriber besuppressed or is it possible to temporarilysuppress the display?If the ARGUS displays an*, it is not possible todetermine the availability of the service, sinceno CLIP has been setup.
(t = CLIR temporarily availablep = CLIR permanently available)COLP: Will the call number of the subscriberwho answered be displayed on the caller'sphone?COLR: Will the display of the call number ofthe subscriber who answered be suppressedon the caller's phone or is it possible totemporarily suppress the display?If the ARGUS displays an*, it is not possible todetermine the availability of the service, sinceno COLP has been setup.
The suppl. services pairs CLIP and CLIR aswell as COLP and COLR will be tested. If CLIRor COLR is setup permanently, it is notpossible to make a clear assessment.
DDI Can a caller directly dial in to an extension onthe PBX access under test?
MSN Is the supplemental service MSN available?
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
85/204
11 Single Tests
85ARGUS 28
CF
(CFU, CFB,CFNR)
In this test, the ARGUS checks the 3supplementary services CFU , CFB and CFNRone after the other to determine whether theyare supported on the access under test.CFU: Can this access immediately forward anincoming call?CFB: Can this access forward an incoming callwhen it is busy; in other words does it supportCall Forwarding Busy?CFNR: Can this access forward an incomingcall when it is not answered?The CF test attempts to setup a call diversionto the call number that is in the memorylocation for “remote call number 1” (see“Saving Call Numbers” on page 185). The CFtest cannot be performed, if this location doesnot contain a valid call number to which it ispossible to divert a call.
CW Does the access under test support callwaiting?
CCBS /CCBS-T(on a P-P
access)
Will the access under test automatically recalla remote subscriber, if the number called wasbusy?
CCNR/CCNR-T(on a P-Paccess)
Will the access under test automatically recalla remote subscriber if the call was notanswered?
MCID Does the access tested allow identification ofmalicious callers (call tracing)?
3pty Does the access under test support a three-
party conference call?For this test, you need the assistance of aremote subscriber, whose call number must beentered.
ECT Is an explicit call transfer supported by theaccess under test?For this test, you need the assistance of aremote subscriber, whose call number must beentered.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
86/204
11 Single Tests
86 ARGUS 28
AOC The ARGUS checks whether the charges canbe sent to the access under test. The test usesa call to oneself to check both AOC-D (AOCduring a call) and AOC-E (AOC at the end of acall).
SUB A call is made to oneself and answered tocheck the transfer of the sub-address in bothdirections.Are sub-addresses supported on the accessunder test?
UUS Does the access under test support thetransfer of user data?
CUG The ARGUS then uses a self call to check
whether the access under test belongs to aclosed user group.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
87/204
11 Single Tests
87ARGUS 28
11.1.3 Suppl. Services Tests – Error messages
If an error occurs during theSupplementary ServicesTests or if it is not possible tosetup a call, the ARGUS willdisplay the correspondingerror code (e.g. 28).Use < ↓ > to scroll through.
In the example, the error belongs to the error class "wrongor invalid number".In the table below, you will find that this is an error from thenetwork and that it reports that the call number wasincomplete or in the wrong call number format (see“CAUSE-Messages – DSS1 Protocol” on page 198.).
Distributing the error codes into error classes:
For further information regarding error codes:“ARGUS ErrorMessages” on page 202, “CAUSE-Messages – DSS1Protocol” on page 198 and “CAUSE-Messages – 1TR6Protocol” on page 200.
Errorclass
Description Cause (fromnetwork)1 TR6 DSS1
CauseARGUSinternal
A No or anotheraccess
__ __ 201,204,205,210,220
B Wrong or invalidnumber
53, 56 1,2,3,18,2122,28,88
152,161,162,199
C One or moreB-channels busy
10,33,59 17,34,47 ___
D Wrong service 3 49,57,58,6365,70,79 ___
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
88/204
11 Single Tests
88 ARGUS 28
11.2 Service check
The ARGUS checks, which of the following services aresupported by the access under test:
The test runs automatically.
For each service, the ARGUS will place a call to itself (to theaccess under test). However, the call will not be answeredso no charges will be incurred.
Service Name in theARGUS display /abbreviation
Language Language / LangUnrestricted DigitalInformation
UDI 64kBit / UDI 64
3.1 kHz Audio Tel.analog / Tel.7 kHz Audio 7 kHz audio / 7 kHzUnrestricted DigitalInformation with tones /
Display
UDI+TA / UDI TA
Telephony Tel.ISDN / Tel.Facsimile Group 2/3 Fax G3 / FaxG3Facsimile Group 4 Class 1 Fax G4 / FaxG4Teletex service basis andmixed mode and facsimileservice Group 4 Classes IIand III
Mixed Mode / Mixed
Teletex Service basis
mode
Teletex / Ttx64
International inter workingfor Videotex
Videotex
Telex TelexOSI application accordingto X.200
OSI
7 kHz Telephony Tel.7kHz / Tel7kVideo Telephony,first connection
Videotel.1 / Vid.1
Video Telephony,second connection
Videotel.2 / Vid.2
Three user-specificServices(see “Services” on page168.)
Userspec.1 /Userspec.2 /Userspec.3 /
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
89/204
11 Single Tests
89ARGUS 28
In the Single tests menu,use < ↓ > to select Servicetest.Open the enter NumbersdialogueEnter the Own number ofthe access under test
There are PBXs that use separate call numbers forincoming and outgoing calls.In this case, for the Service checks, you can enter
a “remote” call number that corresponds to the“own” number that is not stored in the ARGUS.
If the Service check should extend outside of thelocal exchange, it is possible to perform the
Service check in anend-to-end mode .In this case, you must enter the remote call number for asecond terminal device.The ARGUS will then automatically check whether the
remote terminal can accept the call under the variousservices – in other words, whether it is “compatible” withthese services.
In the test results, the second part (second +, - or *) refers tothe answer from the remote exchange.
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
90/204
11 Single Tests
90 ARGUS 28
The ARGUS will display theresults of the test once it isdone.Use the < ↓ > to scrollthrough the test results.The ARGUS makes adistinction between outgoingcalls (the first +, - or *) andincoming calls (the second+, - or *).+ = Service supported- = Service not supported* A definite statement cannotbe given due to the adjacenterror code.
Interpreting the testresults:
Displayed Description
+ + The self call functions OK or the remote end cantake the call for this service
+ - Call was sent successfully, however, it was rejectedon the remote end due to missing authorization.(Error class D in a B-channel message e.g. in aSETUP_ACK or CALL_SENT)
- An outgoing call with this service is not possible(Error class D without a B-channel message)
+ * Call was sent successfully, the call back or call tothe remote end failed (e.g., remote end busy or noB-channel available for the call back).(Error class B, C or E in a B-channel
message)* Wrong number, no B-channel available or other
error(Error class B, C or E without a B-channel message)
If the outgoing call is not successful, it isnot possible tomake a statement about an incoming call. Therefore, youwill never see “- +” or “- *” on the display.
Test results:
8/15/2019 02_ARGUS 28_Manual_U_V_3_00
91/204
11 Single Tests
91ARGUS 28
For outgoing, the Fax G4service is OK. No statementis possible about incoming.The error code 63 indicatesthe cause of the error whichhas occurred(see tables in appendix).In this case, it isrecommended that you havesomeone place a call to theaccess under test using thisservice.The Mixed Mode service ispossible in both directions.
If an error of error class A occurs (see “Suppl. Services
Tests – Error messages” on page 87.) the Service test willbe aborted.
An error of any other error class will coded in decimal (in theexample above 63), assigned to the respective service andthen displayed.
Example:
8/15/2019 02_ARGUS 28_Manual_U_V_3_00