02_ARGUS 28_Manual_U_V_3_00

Embed Size (px)

Citation preview

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    1/204

    ARGUS

    1ARGUS 28

    ARGUS 28Manual

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    2/204

    ARGUS

    2 ARGUS 28

    © by intec Gesellschaft für Informationstechnik mbHD-58507 Lüdenscheid, Germany, 2005

    Alle Rechte, auch der Übersetzung, vorberhalten. Kein Teildes Werkes darf in irgendeiner Form (Druck, Fotokopie,Mikrofilm oder einem anderen Verfahren) ohne schriftlicheGenehmigung reproduziert, vervielfältigt oder verbreitetwerden.

    All rights are reserved. No portion of this document may be

    reproduced, duplicated or distributed in any form (print,copies, microfilm or on any other media) without intec’swritten permission.

    Version: 3.0

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    3/204

    ARGUS

    3ARGUS 28

    1 Introduction ......................................................... 7

    2 Safety Instructions ........................................... 11

    3 Technical data ................................................... 12

    4 Operation - a brief guide .................................. 13

    5 Menu Hierarchy ................................................ 17

    6 Start-Up ............................................................. 23

    7 Setting the type of access ............................... 337.1 Operation on a U-interface access ................. 34

    8 Setting the Access Mode ................................. 358.1 Operation on a BRI, U-Interface or PRI ........... 35

    8.1.1 TE-Simulation mode .................................. 358.1.2 NT-Simulation mode .................................. 358.1.3 Permanent circuit ....................................... 378.1.4 BRI/PRI Monitor ......................................... 468.1.5 BRI/ PRI Recorder ..................................... 498.1.5.1 Administration of the recorded data ........ 51

    8.2 Operation on a POTS (analog) access ........... 568.2.1 POTS terminal ........................................... 568.2.2 POTS monitor ............................................ 56

    9 Operation on an X.21 or V.35 Access ............. 589.1 Start BERT ......................................................... 59

    9.1.1 Display the test results .............................. 609.1.2 Saving the test results in the ARGUS ........ 60

    9.2 BERT wait .......................................................... 61

    10 SHDSL Tests ..................................................... 6310.1 - SHDSL Line Test ............................................ 6410.2 Displaying the stored results ......................... 7210.3 Bit error test ..................................................... 73

    10.3.1 BERT start ............................................... 7410.3.2 BERT wait ................................................ 7810.3.3 B-channel loop ......................................... 79

    10.4 Telephony on permanent circuits ................... 80

    11 Single Tests ...................................................... 8111.1 Test the Supplementary Services ................... 81

    11.1.1 Suppl. Services Test on 1TR6 ................. 8111.1.2 Suppl.service interrogation in DSS1 ........ 8311.1.3 Suppl. Services Tests – Error messages 87

    11.2 Service check .................................................... 8811.3 Bit error test ...................................................... 9211.3.1 Start BERT .............................................. 9411.3.1.1 BERT - saving ...................................... 97

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    4/204

    ARGUS

    4 ARGUS 28

    11.3.1.2 Displaying the stored results ................ 9911.3.2 BERT wait ............................................. 10011.3.3 B-channel loop ...................................... 101

    11.4 X.31 Test ......................................................... 10211.4.1 Automatic X.31-Test .............................. 102

    11.4.2 Manual X.31 Test .................................. 10811.5 CF Interrogation ............................................. 11211.6 CF - Activation ................................................ 11411.7 CF - Delete ...................................................... 11511.8 MSN Interrogation .......................................... 11611.9 Traffic generator (only on a PRI access) ..... 11711.10Time measuring ............................................. 119

    11.10.1 Connection setup time ........................ 12011.10.2 Time measurement: B-channel delay . 12111.10.3 Time measurement: Interchannel delay 122

    12 Connection ..................................................... 12512.1 Setting up an ISDN connection ..................... 12512.2 Clearing down an ISDN connection ............. 13212.3 Operation on a POTS (analog) access ......... 134

    13 Test Manager .................................................. 13713.1 Simultaneously Starting Several Tests ........ 13813.2 Switching Between Tests .............................. 14113.3 Cancel All ........................................................ 141

    14 Automatic Tests ............................................ 14214.1 Automatic Start test ....................................... 14514.2 Display Results .............................................. 14814.3 Sending the results of a tests to a PC .......... 15014.4 Deleting the results of a test ......................... 15114.5 Sending the results of all tests to a PC ........ 152

    15 Level Measuring ............................................ 15315.1 Level measuring on a BRI access ................ 153

    15.2 Voltage measurement on a U-interface ........ 15515.3 Voltage measurement on a POTS access .... 155

    16 L1 status ......................................................... 15616.1 The L1 status of a BRI access ...................... 15616.2 The L1 status of a PRI access ....................... 157

    17 Configuration .................................................. 16017.1 Trace/Remote ................................................. 16017.2 Setting the SHDSL parameters ..................... 161

    17.3 Configuration: ISDN ....................................... 16317.4 Configuration: BERT ...................................... 17017.5 Configuration: POTS ...................................... 17417.6 Configuration: X.31 profile ............................ 178

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    5/204

    ARGUS

    5ARGUS 28

    17.7 Configuration: ARGUS ................................... 18217.8 Saving Call Numbers ...................................... 18517.9 Reset ................................................................187

    18 Accu servicing ................................................ 190

    19 Testing Features with the Keypad ................ 19220 Connection for a PRI network ....................... 19320.1 ARGUS connector Pin Assignments ............ 19320.2 Connection to DTAG NTPM ........................... 19420.3 The ARGUS 28 as Terminal ........................... 194

    21 Appendix ......................................................... 195A) Acronyms ....................................................195B) CAUSE-Messages – DSS1 Protocol ..........198C) CAUSE-Messages – 1TR6 Protocol ...........200D) ARGUS Error Messages ........................... 202

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    6/204

    ARGUS

    6 ARGUS 28

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    7/204

    1 Introduction

    7ARGUS 28

    1 Introduction

    The ARGUS 28 is a compact all-in-one tester, which can beexpanded in individual steps from a SHDSL tester all theway to a universal tester for E1, X.21, V.35, PRI, BRI and

    POTS interfaces.

    ARGUS 28 expansion levels:- Basic tester : SHDSL both remote and central ends,WINplus- Options :

    - SHDSL 4-wire interface- POTS interface- Packet 1: PRI and BRI, WINanalyse- Packet 2: E1/PRI, extended BERT, BERT nx64 kBit/s,

    MegaBERT, USB adapter- X.21 interface with X.21 cable- V.35 interface with V.35 cable- U-interface (4B3T)- U-interface (2B1Q)

    The basic ARGUS 28 supports network operatorsparticularly in the installation and setup of the 2-wire SHDSLsystems. In this case, the ARGUS simulates both thenetwork and the customer side of the SHDSL connection.Even the customer's terminal equipment can be included inthe measurement process by simply connecting it to theoutput on the ARGUS 28, which then serves as a SHDSLmodem.With its rechargeable batteries and internal charger, theARGUS is exceptionally well suited for use in field service.The intuitive menu operation combines convenient cursorkeys and softkeys with a four-line backlit display.

    Besides TE/NT simulation on BRI and PRI accesses, theARGUS 28 also supports TE simulation on U interfaces(optional) and POTS as well as convenient BRI and PRI D-channel monitoring. The 16 megabytes of internal Flashmemory enables the tester to record and save themonitoring data without requiring a connection to computer.

    The Flash-ROM technology permits you to upgrade yourARGUS at any time by download software updates from aPC (free software updates are available at www.argus.info).

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    8/204

    1 Introduction

    8 ARGUS 28

    If you use the ARGUS on a BRI or PRI interface in an ISDNsystem whose specifications deviate from the (DIN ETS 300102) standard (e.g. some networked PBXs), you must takethese manufacturer-specific modifications into account. Insuch cases, please contact the distributor of your ISDN PBXfor assistance.

    To test X.21/V.35 permanent circuits, you can connect theARGUS to the X.21/V.35 network via the X.21/V.35 adapter.

    As an option, a V5.x monitor is available for the ARGUS 28:This monitor can be used to record the V5.1 or V5.2protocol, which can then be decoded in detail with theWINanalyse software. The ARGUS Functions - Overview:

    SHDSL test

    Displays the SHDSL connection's most importantperformance parameters

    Bit error tests (BERT) for SHDSL

    Performs a BERT to a loopbox or in end-to-end operation.

    The ARGUS will, if needed, handle the loopbox functionitself.

    Listen/Talk mode (telephony) in TDM time slices

    Tests a permanent circuit using a telephone connection to aremote end in a selected time slice.

    Protocol Recognition and B-Channel Test for ISDN

    Accesses

    After you select the operation mode, the ARGUS willautomatically determine the protocol supported by theaccess under test and will then test the availability of the B-channels.

    Telephone connections

    Can a telephone call be placed from this access to everyother number and/or can this access receive a call?

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    9/204

    1 Introduction

    9ARGUS 28

    Service Tests

    Does the tested access support connections with the mostimportant services, such as, ISDN telephone service, Group4 - Facsimile or data transmission at 64 kbit/s etc.?Additionally, 3 user-specific services can be saved in the

    ARGUS and tested on the access under test.

    Bit error tests (BERT) for E1, PRI, BRI, U-interfaceaccesses

    Performs a BERT in an extended call to itself via a loopboxor in end-to-end operation. The ARGUS will, if needed,handle the loopbox function itself.The integrated MegaBERT extends the bit error test on E1/ PRI accesses to a full 2 Mbit/s bandwidth. Any distribution

    of time slots (n x 64 kBit/s ) may be used.Supplementary Services

    The ARGUS automatically tests the supplementary servicesmade available by the exchange.

    Leased Line Tests – tests permanent circuits with BERTand speech

    NT simulation of a BRI or a PRI access

    D-channel monitoring on a Basic Rate Interface and ona Primary Rate InterfaceAll of the D-channel signals are captured and passed to theserial interface. When passively monitoring, the ARGUSdoes not affect Layer 1.

    POTS (analog) Functionality

    Does the POTs access support call number transfer?The ARGUS will display the charges, if the access supportsthis feature.

    Monitoring an analog line (passive listening-in)

    CF Interrogation

    The ARGUS will check, whether a call diversion has beensetup on the access under test. The ARGUS can setup orclear down call diversions in the exchange.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    10/204

    1 Introduction

    10 ARGUS 28

    MSN interrogation (only on a BRI access)

    On a P-MP access using the DSS1 protocol, the ARGUSwill determine the MSNs of the access under test.

    X.21/V.35 TestThe ARGUS will perform a bit error test on the X.21/V.35access in accordance with the ITU guidelines G.821 andG.826.

    The Access Acceptance Report

    When the ARGUS is linked to a PC via the serial interface, itis, as an example, possible - with the aid of WINplus - to

    create and print a comprehensive test report on the PC. Testing Features with the Keypad

    Supports manual tests in the so-called keypad mode. If thenetwork supports this feature, the user can send acommand sequence and can then test service features in adialog.

    Should you have any further questions, please contact us:intec Gesellschaft für Informationstechnik mbH

    Rahmedestr. 90D-58507 Lüdenscheid

    Tel.: +49 (0) 2351 / 9070-0Fax: +49 (0) 2351 / 9070-70

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    11/204

    2 Safety Instructions

    11ARGUS 28

    2 Safety Instructions

    The ARGUS may only be used with the includedaccessories. Usage of other accessories may lead toerroneous measurements and may even cause damage to

    the ARGUS and the connected installation.

    The ARGUS is only to be used in accordance with theinstructions in this documentation. Any other usage mayresult in bodily injury and destruction of the ARGUS.

    • To prevent electrical shocks or damage to the ARGUS,do not connect it to lines with voltages in excess of 100V!

    • Never attempt a measurement with the case open!

    • The ARGUS is not watertight. Protect the ARGUS fromexposure to water!

    • Before replacing the battery(see page 16 Replacing theaccumulators), disconnect all the test leads and switchthe ARGUS off.Make certain that the polarity is correct when

    connecting the batteries!

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    12/204

    3 Technical data

    12 ARGUS 28

    3 Technical data

    Dimensions / Weight

    Height 229 mmWidth 72 mmDepth 35 mmWeight 350 g (withoutbatteries and protectivecase)Keypad21 Keys

    LCD displayLCD display withswitchablebackground lighting4 lines with 16 characters

    MemoryEEPROM Non-volatilememory: 2048BytesFlash programmemory: 1 Mbyte

    S-RAM: 256 Kbytes +128 Kbytes

    Data memory: 16 Mbyte(Flash)

    Inputs / Outputs

    1 RJ-45 for BRI, PRI,

    U-interface (optional) orPOTS

    1 jack for an externalpower supply

    1 RJ45 forconnecting to an X.21or V.35 network or a PC

    1 RJ -11 for SHDSL

    Temperature RangesAmbient-temperature:0 °C to +50 °C

    Operatingtemperature:-5 °C to +55 °C

    Power

    Supply3 NiMH accumulatorsor

    9 V, plug-in powersupplyor

    BRI feed

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    13/204

    4 Operation - a brief guide

    13ARGUS 28

    4 Operation - a brief guide

    Power Key:

    - Switch the ARGUS ON- To start up again after a power down- to switch on the display backlighting In battery mode to save power, the

    backlighting will switch off automaticallyafter 5 seconds.- To switch the ARGUS OFF (must be pressed somewhat longer) Confirmation key:

    - Select menu or continue

    Receiver inset

    LEDs

    Softkeys

    Menu control

    Confirmation key

    Layer 1 measurement

    Pickup / Hang upCalling

    Power /

    MicrophoneFastener forshoulder strap

    Numerical

    LCD display4x16 characters

    Display backlighting

    keypad

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    14/204

    4 Operation - a brief guide

    14 ARGUS 28

    Menu control:

    - Open the menu list- Scroll through lists- Select a menu- Select a function in an

    open menuTelephony - Pickup or hang up- Simplified overlap signalling: press the telephone key twice.

    Layer 1 measurement:

    start the Layer 1 measurement(Level/Voltage)

    Number Pad:

    - Entry of the digits 0....9 and of the special characters *, # (e.g. the call number

    or numerical entry in a function)- In special cases entry of alphanumeric

    characters- Direct function call

    Softkeys:The function of the 3 softkeys varies with thesituation. The current function of each softkeyis shown in the highlighted fourth line of thedisplay.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    15/204

    4 Operation - a brief guide

    15ARGUS 28

    Connectors on the end:

    • 9 V-

    Connection for the external power supply.If the plug-in power supply is connected, the ARGUS willautomatically disconnect the accumulators. In this case,the ARGUS will automatically recharge the

    accumulators(see page 190 Accu servicing).

    • Line

    - Connection for a BRI network- Connection for a POTS (analog network)- Connection for a PRI network

    • DSL

    - Connection for the SHDSL network

    • X.21, V.35 / PC

    - Connection for the X.21 or V.35 adapter- Connection to a PC via a serial cable- Connection of a PC via the USB Adapter

    Pin Assignment3/4/5/6BRI7/8 POTsPIN assignment for PRI, see “Connectionfor a PRI network” on page 193.

    Western 4 jack - SHDSL:

    1 Line2 a (TIP)2 Line1 a (TIP)3 Line1 b (RING)4 Line2 b (RING)

    P110

    1234

    WESTERN4SMD

    TIP_2TIP_1

    RING_1RING_2

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    16/204

    4 Operation - a brief guide

    16 ARGUS 28

    Replacing the accumulators

    The battery compartment for the three accumulators(rechargeable batteries) is located on the back of the case.Unscrew the screws to remove the cover of the case andinsert the accumulators in accordance with the polarity

    marking.

    Use only NiMH accumulators.

    The current state of the charge will (if the ARGUS is notconnected to a power supply) be displayed graphically.

    In the LCD display, a battery symbol will begin to blink, whenthere is still approximately 5 minutes reserve. During thisperiod, it is possible that there may be audible interferenceand in rare cases even malfunctions (see “Accu servicing”on page 190.).

    Power Down

    In accu/battery operation, if the ARGUS is idle for 15minutes, it will automatically switch to the power-down mode(power-down).The ARGUS will remain in power-down mode until thePower-Key is pressed again.

    Reasonably enough, the ARGUS willnot enter power-downmode during a test (e.g. Loopbox) or when it is in Tracemode.

    As an alternative, it is possible to operate the ARGUS usingthe included power supply. If the ARGUS is connected tothe plug-in power supply, it will automatically disconnect theaccumulators and will - reasonably enough - not enterpower-down mode.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    17/204

    5 Menu Hierarchy

    17ARGUS 28

    5 Menu Hierarchy

    MenuAccess

    Selection of the physicalaccess

    SHDSL page33Basic Rate Interface(optional) page 33Primary Rate Interface(optional) page 33POTS interface (optional)

    The Access Mode menu willopen automatically

    MenuAccess mode

    TE automatic page 35TE P-P page35TE P-MPpage 35NT P-P page35NT P-MP page

    BRI

    POTS terminal page56

    PO

    STU-C 2-wire page 64STU-R 2-wire page 64STU-R 2-wire/PRI page

    SHDSL

    A list of all the menus willopen

    Switch the ARGUSON

    BRI, PRI, U-Interface,POTS, X21 or V.35 Autodetect: The ARGUSdetermines whether it is aBRI, PRI or POTSaccess.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    18/204

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    19/204

    5 Menu Hierarchy

    19ARGUS 28

    Menu Level Measuring

    Remote end page 153other TE page 153

    BRI,

    Polarity page 155PO

    Menu

    Settings

    Trace/Remote page160

    SHDSL config. page161

    - Spectrum- Clock/framing- Chan. selection- Power back off- EOC using- EOC mode

    ISDN page

    163- L1 permanent?- Protocol- Alerting mode- Clock mode- BRI termination- PRI termination- Sensitivity- Sa5 bits- Sa6 bits

    - A bit- CRC4 mode- Call parameter

    The ARGUS can beconfigured to suit your specialrequirements.The parameters are clearlyorganized in submenus (e.g.the SHDSL parameters are inthe SHDSL submenu)The default (factory) settingscan be restored by selecting

    "Reset“.

    MenuAutomatic Tests

    Start page 145View page148Test data to PC page150

    Delete page 151

    The ARGUS will automaticallyexecute the test sequence and save the resultsin its internal Flash

    MenuL1 status

    The ARGUS displays the current status ofLayer 1 on a BRI access (page 156 ) and theLayer 1 parameter on a PRI access (page157 ).

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    20/204

    5 Menu Hierarchy

    20 ARGUS 28

    - DTMF / Keypad- Dest. no. MSN- CUG Index

    BERT page171

    - BERT duration(time)

    - Error level- HRX value- Bit patt. BRI/U- Bit patt. PRI- Bit patt. SHDSL- Bit patt. X.21

    POTS page

    174- POTS dial- POTS CLIP- AOC pulse- DTMF parameter- FLASH time

    X.31 profile page178

    - Packet number

    - TEI- LCN- Packet size- Agree PS- Window size- Agree WS- Throughput- Agree DS- User data- CUG- CUG Index- D bit- Facilities- Profile name

    Device:page 182

    - Menu language- LCD contrast- Date / Time- Baud rate- Alarm- Feed- Battery type

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    21/204

    5 Menu Hierarchy

    21ARGUS 28

    Menu Accu servicing

    Charging page 190Discharging

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    22/204

    5 Menu Hierarchy

    22 ARGUS 28

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    23/204

    6 Start-Up

    23ARGUS 28

    6 Start-Up

    Using the included cable, connect the ARGUS to the accessto be tested.

    Power Key: Switch on the ARGUS.The ARGUS displays theaccess and modeparameters which were lastselected.

    Displayed in the first line:The software version number: 2.9 (in the example)Country code: u (=Great Britain), e (=Spain),f (=France), . . .The state of the accumulator charge (if it is not connected tothe plug-in power supply)

    Displayed in the third line:

    Type of access: SHDSL, optional: BRI, U-interface, PRI ,POTS or X.21 or V.35 test

    Operation mode: STU-C 2-wire.(Access mode) STU-R 2-wire.

    STU-R/PRI

    NT = NT SimulationTE = TE SimulationPerman.swit.MonitorRecorderTerminal (only on a POTS (analog)

    access)

    Bus configuration: P-P = point-to-pointP-MP= point-to-multipoint

    Displayed in the fourth line:

    The fourth line displays the current assignment of the threesoftkeys below.

    The ARGUS is in largest part operated with the two↓ ↑ -Keys, the confirmation key and the three softkeys.On the following pages, only the softkey's meaning in the

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    24/204

    6 Start-Up

    24 ARGUS 28

    respective context is shown - enclosed in brackets , e.g.< NO >.The < > softkey serves the same function as theconfirmation key and the softkey performs the samefunction as the corresponding arrow key on the ARGUSkeypad.

    Using the ↓ ↑ -Keys or the softkey select the physicalaccess corresponding to that of the access under test.If Automatic is selected in this menu, the ARGUS will

    Level ofbatteries' charge

    The

    currentassignmentof thesoftkeys willbe displayed.

    Activation of the displayedparameters. The ARGUS will beginthe initialization phase and thenshow the status display (see Chap.page 30).

    The displayed parameters will notbe accepted.The Access menu will now open(Page 33):

    Operating modeType ofaccess

    Software version:

    MarkedType ofaccess

    The list

    continues

    Return toStartingwindow

    Name ofthe menu

    The ARGUS acceptsthe type of function/ submenu marked with→ .TheAccess Mode menu willopen.

    scrollfurther.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    25/204

    6 Start-Up

    25ARGUS 28

    automatically determine the physical access (BRI, U-interface, PRI or POTS). In this case, the ARGUS sets theBRI access to TE-mode (see “Setting the Access Mode” onpage 35).

    In this case, the Access Mode menu will not open

    and consequently functions such as BRI Monitor,BRI Recorder and Permanent Circuit will not beavailable.

    If SHDSL, BRI, POTS or PRI is selected, theAccessMode (see Chap. 8 page 35) menu will open.

    Initialization phase:

    - Operation on a SHDSL access

    The ARGUS displays theaccess mode and thevoltage on the SHDSL line.

    - Operation on a BRI or U-interface access or operationas a BRI NT simulator:

    Once the access and access mode parameters have beenselected or accepted, Layer 1 will be setup. While Layer 1 isbeing setup, the L1 LED above the display will blink. If theARGUS cannot setup Layer 1, it will display the message" No Net “.

    When the ARGUS is operated on a U-interface access, itcan take up to 2.5 minutes to activate Layer 1.

    MarkedAccess mode

    scrollfurther

    Return tothe Access

    Name of the menu

    The ARGUS acceptsthe - with a→ marked-Access Mode.The ARGUS will thenstart the

    List iscontinued

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    26/204

    6 Start-Up

    26 ARGUS 28

    As soon as Layer 1 is successfully setup, LED L1 will lightcontinuously.

    Once Layer 2 has been setup LED L2 will light.

    If both modes (P-P / P-MP) are found when Layer2 on the D-channel is checked, the mode must beselected manually (see Page 35).

    If everything has been correctly detected, the ARGUS willdisplay the access type and mode found. Additionally, aqualitative assessment of the level will be displayed.

    The ARGUS will automatically determine the protocol (inboth TE and NT mode) or use the protocol selected in theConfiguration/ISDN menu (see on page 163 “Configuration:ISDN”) . On a bilingual access, the ARGUS will use theDSS1 protocol.

    LED L3 will light after the ARGUS has setup Layer 3.At the same time the ARGUS will start the B-channel test.The results will be displayed on the ARGUS. If an erroroccurs in the B-channel test (e.g. access is not plugged-in),

    the ARGUS will - depending on the class of error - eitherrepeat the initialization or show an error message ((seepage 202 ARGUS Error Messages)).

    The ARGUS will then idle in the Status display.

    The ARGUS displays thetype of access (BRI), theavailability of the B-channels(B12), a level evaluation(OK),the access mode (TEs), thebus configuration (P-MP)and the protocol (DSS1).Press the torepeat the B-channel test.

    The ARGUS in its Mainmenu

    Status display example:

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    27/204

    6 Start-Up

    27ARGUS 28

    The test found that it is a BRI multiple device access usingthe DSS1 protocol.

    Shown on the second line in the display:The availability of the B-channels:B12 both channels are availableB1- only B-channel 1 is availableB-2- only B-channel 2 is availableB-- no B-channel available

    If only one B-channel is available, this can have animpact on the service check and the testing of thesupplementary services.

    Level evaluation only on a BRI access:OK the level is in order> the level is too high-- no level

    Shown on the third line in the display:Access Mode:NTs = NT Simulation Slave ModeNTm = NT Simulation Master ModeTEs = TE Simulation Slave ModeTEm = TE Simulation Master Mode(see page 165 Clock mode)

    Bus configuration:P-P: Point-to-PointP-MP: Point-to-Multipoint

    It must be mentioned again, that the ARGUS onlydetermines the general bus status once when switched onor when the ARGUS first connected.On the other hand, the status of the protocol stacks for Layer1, 2 and 3 will be continually monitored and displayed.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    28/204

    6 Start-Up

    28 ARGUS 28

    - Operation on a PRI access

    As soon as Layer 1 is setup, LED L1 will light continuously.The ARGUS will automatically determine and display,whether or not the PRI access uses CRC4-monitoring.CRC4 monitoring can be switched on or off manually ((see

    page 167 CRC4 mode)).

    The ARGUS will begin the automatic detection of the accessconfiguration. After Layer 2 is setup, the L2 LED will alsolight.The ARGUS will, regardless of the mode of operation (TE orNT mode), determine the D-channel protocol and attempt tosetup Layer 3.

    During this phase, the

    ARGUS displays the A bit ofthe remote side. Protocoldetection is only possiblewhen the A bit is not set (+).Afterwards, the B-channel

    test will be started.

    With the B-channel test, the ARGUS checks the availabilityof all 30 B-channels by placing an outgoing call on each B-channel one after the other. If the call can be setup, it isassumed that the B-channels are available from both ends.

    If the connection is rejected with Cause 44 (see AppendixB), the B-channel will be assumed to be only available forincoming calls.

    If the connection is rejected for any other cause, the B-channel will be identified as unavailable. In the case of acause, which indicates that the B-channel is occupied, theconnection will be tried up to two times and, if a connectioncan still not be setup, it will then be marked as unavailable.

    Displayed in the first line:Type of access: PRI

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    29/204

    6 Start-Up

    29ARGUS 28

    Displayed in the second line:Available B-channels: The light squares represent the

    available B-channels ordered in twoblocks of 15. The upper row ofsquares represent the B-channels thatare available for outgoing connections,the lower row represents those thatcan be used for incoming calls.left: B-channel 1right: B-channel 30

    Displayed in the third line:

    Operation mode: NTs = NT Simulation Slave Mode(see page 165 Clock mode)

    NTm = NT Simulation Master ModeTEs = TE Simulation Slave ModeTEm = TE Simulation Master Mode

    Layer 1 mode: With (CRC) and without CRC4(NoCRC)

    D-channel protocol: Auto, 1TR6, DSS1, none,BILINGUAL, CorNet-NQ

    CorNetN , CorNetT, QSIG or VN4

    Test sample: The test found that it is a PRIaccess using CRC4-monitoring and the DSS1protocol. All 30 B-channelsare available and can beused for outgoing oralternating connections.

    The B-channel test cannotdistinguish between alternating and exclusively "outgoing"B-channels.

    The ARGUS is in the NT-Simulation Master modeand is connected to aterminal using the DSS1 D-channel protocol without

    CRC4-monitoring.B-channel 11 is notavailable.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    30/204

    6 Start-Up

    30 ARGUS 28

    The first 10 B-channels areconfigured in the exchangeas incoming channels only(seen from the viewpoint ofthe terminal), while B11-B30can be used for outgoing oralternating connections.

    The ARGUS is not properlyconnected (e.g. wrongcabling) or the network is notin order.

    - Operation on a POTS access

    The ARGUS displays theaccess type (POTS) and theline voltage when idle.

    ARGUS - Main menu

    In the Main menu, you can scroll through the availablemenus with the key:

    Status display

    Main Menu

    Repeat B-channel test

    scrollfurther.

    Return toStatus display

    The ARGUS opensthe - marked with a→-

    MarkedMenu The list

    continues

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    31/204

    6 Start-Up

    31ARGUS 28

    With the < >, you can open the menu currently marked withthe → (in the example Single Tests).

    SHDSLaccess

    PRI access BRI access

    POTSaccess

    Single Tests Single Tests Single Tests Single Tests

    Test Manager Test Manager Test Manager _______

    Automat.Tests Automat.Tests Automat.Tests Automat.Tests

    ________ ________ Level

    Measuring

    Level

    Measuring

    ________ L1 Status L1 Status _______

    Configuration Configuration Configuration Configuration

    Access Access Access AccessAccu servicing Accu servicing Accu servicing Accu servicing

    U-interface X.21 or V.35

    Single Tests Single Tests

    Test Manager ________ Automat.Tests Automat.Tests

    Level Measuring ________

    Configuration Configuration

    Access Access

    Accu servicing Accu servicing

    Name of theopened menu

    scrollfurther.

    Return topreviously shown

    Display

    The ARGUS opensthe type of function/

    submenu marked with→ .

    List iscontinued

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    32/204

    6 Start-Up

    32 ARGUS 28

    Using the numeric keys to start a function:

    Using the digit keys, you can start important ARGUSfunctions directly, regardless of the currently active menulevel.

    SHDSL access:Numeric key 6 Start Test ManagerNumeric key 7 Open Speed-Dialing MemoryNumeric key 9 Start Bit Error Rate Test (BERT)

    BRI access or PRI access:Numeric key 2 Start Service checkNumeric key 3 Start Supplemental Service TestNumeric key 4 Start Auto. TestNumeric key 6 Start Test ManagerNumeric key 7 Open Speed-Dialing MemoryNumeric key 8 Trace ON/OFFNumeric key 9 Start Bit Error Rate Test (BERT)

    If a function is called where the ARGUS expects theentry of a digit, pressing a number key will beinterpreted as the expected input.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    33/204

    7 Setting the type of access

    33ARGUS 28

    7 Setting the type of access

    If the parameters displayed at power on are not accepted,the Access menu will open automatically.However, you can also open the Access menu at any timefrom the Main menu.In the Access menu, the user must select the type ofphysical access to which the ARGUS is actually connected.When the ARGUS is restarted, the settings used last will besuggested as the default.

    If you press the softkey, the B-channel test

    will be repeated.Open theMain menu

    Using the < ↓ > select theAccess menu

    The Access menu will open

    Using the select thetype of access(e.g. SHDSL)

    Confirm the access

    The Access Mode menu willopen automatically.

    The following applies for all displays: If you press the< > , the ARGUS will return to the previous display.

    IfAutomatic is selected, a fully-automatic sequence will bestarted: The ARGUS will automatically determine the type ofinterface (BRI, PRI or POTS) and set the access to TE-mode.

    Status display

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    34/204

    7 Setting the type of access

    34 ARGUS 28

    7.1 Operation on a U-interface access

    To test a U-interface access, the ARGUS is connected viathe U-interface adapter to the U-interface access.

    As the physical access,select BRI in the Accessmenu.

    The Access Mode menu willopen automatically: In thecase of a U-interfaceaccess, you must choose -as Access Mode - TEAutomatic, TE P-P, TE P-MPor permanent circuit.

    onnection to a U-interface access:

    What the LED on the U-Interface Adapter indicates:

    LED is red: not activated, e.g. cable notconnected correctly

    LED flashing (green/red) slowly - once per second: U-interface is activated; the ARGUS, however, is deactivatedLED flashing (green/red) quickly - twice per second:ARGUS is activated, U-interface is deactivatedLED is green: everything correct

    Connectionto Line jack

    Connection tothe

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    35/204

    8 Setting the Access Mode

    35ARGUS 28

    8 Setting the Access Mode

    The Access Mode menu isnot selectable from the Mainmenu.It opens automatically oncethe physical access isselected in the Access menu.

    8.1 Operation on a BRI, U-Interface or PRI

    8.1.1 TE-Simulation mode

    TE automatic

    On a BRI or U-interface access, the ARGUS willautomatically determined the D-channel Layer 2 mode(PP or P-MP). If the ARGUS determines that the accesssupports both modes, the following Configuration menuwill open:

    Using the , selectL2 mode.

    Confirm the selectedL2mode

    The ARGUS will returnto the Main menu.

    TE P-P or TE P-MP

    Afterwards, the access and the protocol stack will beinitializedin accordance with the selected setting.When the ARGUS finds a PRI access, it will enter P-Pmode.The ARGUS will then jump to the Main menu.

    8.1.2 NT-Simulation mode

    NT P-P or NT P-MP

    Afterwards, the access and the protocol stack will beinitialized

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    36/204

    8 Setting the Access Mode

    36 ARGUS 28

    in accordance with the selected setting.When the ARGUS finds a PRI access, it will enter P-Pmode.The ARGUS will then jump to the Main menu.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    37/204

    8 Setting the Access Mode

    37ARGUS 28

    8.1.3 Permanent circuit

    With the , selectPermanent switch .

    Access modeconfirmed

    The ARGUS is now switchedtoPermanent circuit mode (thedisplay shows LL [LeasedLine]) and will open theStatus display.

    Besides dial-up connections to any subscriber, ISDN alsosupports the use of permanent circuits switched to a specificremote location.

    These permanent circuits are available after setting upLayer 1, in other words after synchronizing both terminals byexchanging HDLC-frames.

    The location where the clock is generated can be selected(see page 165 Clock mode).

    As a quick test of a permanent circuit, you can simply callthe opposite end using a selected B-channel.However, for a more revealing test of a permanent circuit,you should perform a bit error rate test.Both ends of the permanent circuit must use the samechannel.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    38/204

    8 Setting the Access Mode

    38 ARGUS 28

    Telephony on permanent circuits

    The function can be started with the -Key or via thePhone / connec. function in theSingle tests menu (seeChap. 12 page 125).After the B-channel for the permanent circuit is selected, thetelephone connection will be setup automatically.

    The ARGUS displays the B-channel used (e.g. B01) andthe duration of thepermanent circuit.Using the < TM > softkey:Start Test Manager(seeChap. 13 page 137)

    Terminate permanentcircuit

    The ARGUS will open theStatus display

    BERT on permanent circuits

    A number of variations are possible in testing the permanentcircuit with the bit error rate test.

    In the simplest case, a B-channel loop will be set up at theremote end.Start the BERT from theSingle tests menu / Bit error testsubmenu / BERT start (see page 94 Start BERT). Afterselection of the channel to be tested (B-channel or D-channel), the ARGUS will send the test pattern, receive itback and evaluate it accordingly.

    The displays and operation are, in largest part, similar tothose of a BERT on a dial-up connection (see page 92 Biterror test), you simply need not enter call numbers or selecta service.

    In the case of a BRI access in end-to-end mode (on page 92“Bit error test”and on page 100 “BERT wait”), it is alsopossible to run a BERT in the D-channel.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    39/204

    8 Setting the Access Mode

    39ARGUS 28

    In this case, the channel select window will open:On a BRI access:

    With the < ↓ > , select thechannel

    Selecting a B-channel (e.g64k)

    Enter the B-channel on thekeypad. If you enter an *, theARGUS will choose any B-channel that is free.

    Confirm the selected channeland start the BERT.

    The ARGUS will display- the bit pattern (e.g. 2^15)- the channel / bit rate used(e.g. B02/1984k)

    - the remaining test time in Hours: Minutes: Seconds(e.g. 00:24:12)

    - the bit errors that haveoccurred (e.g. 2)- Synchronicity of the

    bit pattern (synchron)- the LOS-counter (e.g. 0).

    Use the softkey toinsert artificial bit errors to testthe reliability of the BERT.Use the softkey to StartTest Manager. see “TestManager” on page 137

    Once it is over, the ARGUS will display the results of theBERT (see “Start BERT” on page 94).

    BERTstop

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    40/204

    8 Setting the Access Mode

    40 ARGUS 28

    On a PRI access:

    In the case of a PRI access in end-to-end mode (see “Biterror test” on page 92and see “Start BERT” on page 94), aBERT can be run- in the D-channel

    - in all B-channels- in all B-channels and in the D-channel (framed)- in selected B-channels- in all channels and time slot 0 (unframed).

    The channel select mask will open.In this mask you can chose from 3 predefined channelpatterns:- MegaBERT framed (default: all B-channels and the

    D-channel)- MegaBERT unfr. (default: all B-channels, D-channel

    and time slice 0)- B-chann. (1..30) (default: all B-channels)

    All three channel patterns can be changed as needed andsaved under any name desired.

    When the parameters (see Page 187) are reset,the channel patterns are reset to their defaultsettings.

    With the < ↓ > select thechannel pattern (e.g. B-chann.(1..30)

    To edit the channel pattern

    Edit the channel patternsee Page 41 Editing theselected channel pattern

    -Key

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    41/204

    8 Setting the Access Mode

    41ARGUS 28

    If desired, enter the new namefor the pattern to be storedunder. When the right softkeyis pressed it assumes adifferent meaning and thusinfluences the entries madefrom the keypad (letters ordigits) see Page 180.

    Store channel pattern

    Start BERT with selectedchannel pattern

    When "Selection“ is chosen,the BERT will start as soon asa channel pattern is entered.

    Setting the channel pattern

    BERT start

    Editing the selected channel pattern:

    In the channel selection window, the light squares representtime slot 0 (upper display line left square), the D-channel

    -Key

    Start BERT

    Start BERT

    -Key

    TimeSlot 0

    D-

    Available B-channels ordered in two

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    42/204

    8 Setting the Access Mode

    42 ARGUS 28

    (the left square on the lower display line) and the B-channels are assigned to the two blocks of 15 (upper displayline B-channels 1 to 15, lower display line channels 16 to30). The selected channels are indicated in the upper row bymarked squares. The marked squares in the lower rowindicate the current position of the cursor.

    The cursor is moved with the arrow keys:↓ -Key moves the cursor one position to the left↑ -Key moves the cursor one position to the right.The channels can also be marked with the cursor directlyusing the numerical keypad: If you enter the digits 08, thecursor will jump to B-channel 8. If you enter *, the cursor willmove to time slot 0 and the entry of the # will move thecursor to the D-channel.

    Time slot 0 can only be selected, when all otherchannels (all B-channels and the D-channel) areselected (i.e are free).

    If the right softkey shows , pressing the softkey < ALL >will select all B-channels and the D-channel (Mega BERTframed). When the right softkey shows , pressing thesoftkey < ALL > will deselect the currently selected channels.

    Channel selection examples:

    No B-channel has beenselected; the cursor is sittingat B-channel 10 (markedsquare in the lower row). TheARGUS shows that thechannel marked by the cursorhas not yet been selected(B10:- ) and is free (free ).

    With < ON >, select thechannel

    B-channel 10 is selected(marked square in the upperrow)

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    43/204

    8 Setting the Access Mode

    43ARGUS 28

    No B-channel has beenselected; the cursor is sittingat B-channel 10.

    With < ALL >, select allchannels except time slot 0.

    The cursor is sitting at timeslot 0.

    With < ON >, select themarked channel (time slot 0).

    Time slot 0 is selected(TS0:+) and is still marked by

    the cursor (both squares aremarked)

    Channels 5 to 8 wereindividually marked with thecursor and selected with; the cursor is at B-

    channel 8.

    Channels 5 to 8 and 20 to 23have been selected.The cursor is at channel 24.Channel 24 cannot beselected, since it is busy.

    Mega

    BERTframed

    Mega BERTunframed

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    44/204

    8 Setting the Access Mode

    44 ARGUS 28

    Loopbox with a permanent circuit

    A loopbox can be setup for the permanent circuit byselecting in theSingle tests menu / Bit error test submenu / the B-channel LOOP (see “B-channel loop” on page 101).

    The Channel select windowwill open.

    When "B-channel" isselected, the Loopbox issetup for both B-channels.If "All framed" is selected, notonly both B-channels but theD-channel will also belooped.

    Activate loopbox

    The ARGUS will display thechannel used (B01) and theamount of time (h:min:sec)that the Loopbox has been

    active.

    If B-channel is selected,the loopbox can be setup forB-channel 1 to 30.

    If All framed is selected,not only both B-channels butthe D-channel will also belooped.If All unframed isselected, not only the B-channels and the D-channelbut also time slot 0 will belooped.

    On a BRI access:

    Loopboxstop

    On a PRI access:

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    45/204

    8 Setting the Access Mode

    45ARGUS 28

    Switching from permanent circuit mode

    Using the < ↓ >, select theAccess menu.

    The Access menu will open

    Using the < ↓ >, select thedesired access.

    The Access mode menu willopen.

    Using the < ↓ > , select thedesired Access mode (e.g.TE P-MP).

    Confirm the selected accessmode

    The ARGUS will open theStatus display

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    46/204

    8 Setting the Access Mode

    46 ARGUS 28

    8.1.4 BRI/PRI Monitor

    The ARGUS accepts all of the D-channel signals from theBRI or PRI access and sends these D-channel signals overthe serial interface to a PC, which must be running ARGUSWINplus or WINAnalyse. The bus and Layer 1 are not

    influenced by the monitoring.

    Monitoring a BRI access

    Using the< ↓> , selectMonitor .

    Confirm the selected accessmode

    The ARGUS evaluates thelevel on the NT-side: OK, > (too high), _ (nolevel)(Monitoringnot yet active)

    Start monitoringThe Trace LED lights.

    The ARGUS displays thenumber of recorded signals(e.g. 25) and the recordingtime in h:min:sec.Select < ABORT > to stopmonitoring.

    Listening-in on voice data

    The B-channel select dialog

    will open.Enter the B-channel. TheARGUS will switch thehandset to this B-channel. It isnow possible to listen to thevoice data (in the directionNetwork --> User).

    Listening

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    47/204

    8 Setting the Access Mode

    47ARGUS 28

    Simultaneous call display while monitoring a BRIaccess

    While monitoring, the ARGUSwill search all of the D-channels signals sent for aSETUP. If a SETUP isdetected, the softkeywill be displayed.

    Display the call parameters ofthe last SETUP received.

    The ARGUS displays the calldirection (Net -> User), theservice (e.g. FaxG3), the ownnumber (e.g. 125670), thechannel used (e.g. B01) andthe destination number (e.g.02351 901729).

    Display of other parameters:Sub-address (SUB),User-User-Info (UUI),DSP messages (ifexistent),Type of Number (T.O.N) ,

    Numbering plan (NP).

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    48/204

    8 Setting the Access Mode

    48 ARGUS 28

    Monitoring a PRI access:Same procedure as when monitoring a BRI access

    ARGUS messages on a PRI access:As soon as a change occurs, the ARGUS will send a time-stamped report of the following alarms/states to the PC,which will evaluate them:

    - Signal- FAS- CRC4det- A bit- AIS

    The ARGUS will check the following values and countersevery second and, in the event of a change, will pass themon the PC:

    - Sa5-bit (Rx)

    - Sa6-bit (Rx)- E-bit- Ecnt- CRC Err.- Cod.Err.- Fram.Err.

    Display of the L1 Status in PRI Monitor mode

    The L1 status function is only available in PRI Monitor

    mode.The Layer 1 alarms and messages are presented in severalwindows, which permit detailed statements regarding thestate of the PRI access and the transmission line (Forfurther information, see the CCITT/ITU guidelines G.703 andG.704).When the function is started, it will first automatically openthe “L1 status TE” function, which shows the “TE-sideparameter”. For a comprehensive explanation of thedisplayed information: see “The L1 status of a PRI access”on page 157.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    49/204

    8 Setting the Access Mode

    49ARGUS 28

    The ARGUS is in PRI Monitormode(Monitoring isnot active)

    With the< ↓ >, selectL1 status .

    Display of the "TE-sideparameters"Use the ↓ -Key to scrollthrough the display.

    Press < NT > to switch to the“L1 status NT” function; the“NT-side parameters” will bedisplayedPress to reset theHistory function and allcounters.Press < ABORT > to quit thefunction and return to themenu list.

    8.1.5 BRI/ PRI Recorder

    In Recorder mode, the ARGUS passively monitors theconnected BRI or PRI access.The ARGUS records all of the D-channel signals sent inboth directions without affecting the access or Layer 1.Unlike in the Monitor mode, the recorded D-channel signals

    will be saved in the ARGUS’s internal Flash memory and notsent to a PC.The storage is organized as a ring buffer, i.e. as soon as theFlash memory is full, the ARGUS will automatically overwritethe oldest data.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    50/204

    8 Setting the Access Mode

    50 ARGUS 28

    Select BRI Recorder (or PRIRecorder on a PRI access).

    Start the Recorder function.

    The ARGUS is now inRecorder mode (Monitoring isnot yet active!) and will checkthe levels on the NT and TEsides of the BRI access.Displayed in the second line:Level on the NT-side (> too high, OK, ___ nolevel), level on TE-side (> too high, OK, ___ no level)

    Recording started(The Trace LED flashes)

    The display shows thenumber of signals receivedand the duration of therecording in

    hours:minutes:seconds.Using , switch thespeech path onto a B-channel. First the B-channelselect dialog will open. Afterselecting a B-channel, it willbe possible to listen to thevoice data (in the directionNetwork ----> User) on thischannel.

    Parallel call display while recording

    The ARGUS searches all of the D-channel signals sent for aSETUP. If a SETUP is detected, the softkey will bedisplayed.Use to display the call parameters of the lastSETUP received. (see page 47 Simultaneous call displaywhile monitoring a BRI access)

    Example on a BRI access:

    Quitting the activerecording function. TheARGUS is then in the“Recorder” mode.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    51/204

    8 Setting the Access Mode

    51ARGUS 28

    Operation on a PRI access:

    Use to switch theARGUS speech path onto aB-channel. First the B-channel select dialog willopen. After selecting a B-channel, it will be possible tolisten to the voice data (in thedirection Network ----> User)on this channel.Use < ABORT > to stop theactive recording function. TheARGUS is then in the“Recorder” mode.

    The ARGUS saves a timestamped report of any changes inthe following alarms/states:

    - Signal- FAS- CRC4det- A bit

    - AISThe ARGUS will check the following values and countersevery second and, in the event of a change, will save them:

    - Sa5-Bit (Rx) / (Tx)- Sa6-Bit (Rx) / (TX)- E-Bit- Ecnt- CRC Err.- CRC rel.

    - Cod.Err.- Cod.rel- Frm.Err.

    8.1.5.1 Administration of the recorded data

    In the Recorder mode, several functions are available for

    Time Slot 16

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    52/204

    8 Setting the Access Mode

    52 ARGUS 28

    administration of the data saved in the Flash memory:- PC load all- PC load session- Reset Flash- Info Flash

    PC load all

    With thePC load all function, all of the contents of the Flashmemory will be downloaded via the serial interface to thePC, which must be running either WINplus or WINanalyse.

    The ARGUS is in "Recorder"mode(Recording not active)

    Using < ↓ >, selectPC load all .

    Start charging the

    accumulators

    Select < ABORT > to stop thetransfer.

    After the data has beensuccessfully transferred to the

    PC, the Flash memorycontents can be deleted.Select < YES > to delete theFlash memory contents.Select < ABORT > to quit andnot delete the Flash memorycontents.

    PC load session

    In the ARGUS, the storage in the internal Flash is organized

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    53/204

    8 Setting the Access Mode

    53ARGUS 28

    as a ring buffer, which can hold the data from a series ofseveral sessions (i.e. independent trace recordings). At thestart of each session, the date and time will be written in thering buffer.ThePC load session function transfers all of the data session-by-session to the PC on which either WINplus orWINanalyse must be running. The time and date that thesession was started will be displayed in WINplus/ WINanalyse.

    The ARGUS is in "Recorder"mode(Recording not active)

    Using < ↓ > , select PC loadsession .

    The loading of theindividual sessions willstart.

    Select < ABORT > to stop thetransfer.

    Multiple sessions can betransferred to the PC oneafter the other.Press to loadthe next session to the PC.

    After the data has beensuccessfully transferred to thePC, the Flash memorycontents can be deleted.Select < YES > to delete theFlash memory contents.Select < ABORT > to quit andnot delete the Flash memorycontents.

    Internal decoding

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    54/204

    8 Setting the Access Mode

    54 ARGUS 28

    The ARGUS will decode the D-channel data stored in theFlash memory:

    Using the < ↓ >, selectInternal decod. .

    Display the signals sent to thenetwork ("

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    55/204

    8 Setting the Access Mode

    55ARGUS 28

    Reset Flash

    The Reset Flash function will delete the entire contents ofthe data Flash memory.

    The ARGUS is in "Recorder"mode(Recording not active)

    With the < ↓ >, select ResetFlash .

    Select < YES > to delete theFlash memory contents.The procedure can takeseveral seconds. The ARGUSwill show the progress of thedeletion as the percentagedone.It is not possible to stop theprocess of deletion!

    Use < ABORT > to return to theprevious menu; the contentsof the Flash memory willnotbe deleted.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    56/204

    8 Setting the Access Mode

    56 ARGUS 28

    8.1 Operation on a POTS (analog) access

    8.1.1 POTS terminal

    Using the< ↓ >, selectPOTS interface .

    Confirm the access

    Using the< ↓ >, selectPOTS terminal .

    The Argus behaves like aPOTS (analog) terminal.

    The ARGUS will return to theMain menu.

    8.1.2 POTS monitor

    Essentially, the POTS (analog) monitor provides a highimpedance tap that does not influence the interface.You can listen to the line with the integrated handsetwithout having the ARGUS send on or otherwiseinfluence the interface.

    The ARGUS displays thevoltage level on the line whenit is "on hook“ (not busy).

    Start monitoring

    The ARGUS displays thevoltage (when "off hook"), thenumber of the caller (whenCLIP is supported) and theDTMF characters dialed byboth telephone subscribersand the SMSs received(optional).Any received DTMF-characters will be appendedto the line, which will shift leftfor each character once it is.

    full.

    Monitoringstop

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    57/204

    8 Setting the Access Mode

    57ARGUS 28

    An incoming call will be signalled acoustically.Press the < ↓ > -Key to display additional information, ifavailable on the access (e.g. advice of charges).Press < DEL > to clear the display.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    58/204

    9 Operation on an X.21 or V.35 Access

    58 ARGUS 28

    9 Operation on an X.21 or V.35 Access

    The ARGUS will perform a bit error test on the X.21 or V.35access in accordance with the ITU guidelines G.821 andG.826.

    Besides the measurement results, the ARGUS will alsodisplay the X.21/V.35 data rate.

    Use the adapter cable to connect the ARGUS to the X.21/ V.35 network.

    Use the < ↓ > to select X.21 .

    X.21 Interface Adapter

    Connection to Connection to X.21networkor X.21 standard

    Example - on an X.21

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    59/204

    9 Operation on an X.21 or V.35 Access

    59ARGUS 28

    9.1 Start BERT

    The ARGUS will detect the clock of the X.21/V.35permanent circuit, calculate the data rate and thenautomatically search for the channels used. On these

    channels, the ARGUS will send the test pattern (see page172 Bit pattern BRI/U) selected, receive it again andevaluate it in accordance with the ITU guidelines G.821 andG.826 (loopbox required at the remote end).

    Press to start theBERT

    Displays the bit pattern(2^15), the X.21/V.35 datarate (1984 kBit ), theremaining test duration inh:min:sec (15:45:42), thenumber of bit errors that haveoccurred (3), thesynchronicity of the bit pattern(synchron) and the LOS-counter.

    Press to restart thebit error test; the counters(e.g. number of bit errors) willbe reset.Press to inject an“artificially generated” biterror, which can demonstratethe reliability of themeasurements in particularwhen running end-to-endtests.

    When a bit error is detected, this will be signaledby a brief alarm (if the alarm is enabled); in theevent that the synchronisation is lost, a constantalarm will sound.The alarm bells can be switched off.(see page 184 Alarm bell).

    The measurement time for the BERT can be set with theBERT config. function (see page 171 BERT - duration).

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    60/204

    9 Operation on an X.21 or V.35 Access

    60 ARGUS 28

    9.1.1 Display the test results

    The ARGUS will display the following test resultsautomatically after the test is completed:- Bit pattern and X.21/V.35 data rate

    - Transferred data in kBits (in the example 10309 kBits)- Number of the bit errors that have occurred (in the example10)- Bit error rate (in the example 9.7·10-7 (= 0.00000097))The evaluation of the results depends on the error thresholdthat you set ((see page 171 Error level)).OK = bit error rate is less than the error threshold (set by theuser) and NO = bit error rate is above the error threshold.

    Press < MORE > to displayother characteristic values(in accordance with ITU-TG.821and G.826) All valuesare given in percentages.The ARGUS evaluateswhether the test resultssatisfy the limits specified inthe CCITT G.821/G.826under consideration of thedefined hypotheticalreference connection HRX(display shows OK or NO).(see page 92 Bit error test)Press < MENU > to return tothe BERT menu.

    9.1.2 Saving the test results in the ARGUS

    Display of the results

    Press the -Key

    Press to have theARGUS save the results.(see page 97 BERT - saving)

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    61/204

    9 Operation on an X.21 or V.35 Access

    61ARGUS 28

    9.2 BERT wait

    In this mode, the BERT will wait for the BERT at the remoteend which is necessary for an end-to-end test:see “BERT wait” on page 100.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    62/204

    9 Operation on an X.21 or V.35 Access

    62 ARGUS 28

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    63/204

    10 SHDSL Tests

    63ARGUS 28

    10 SHDSL Tests

    The ARGUS supports a variety of access types.Depending on the access mode selected (and the protocol),the following single tests are supported:

    The ARGUS displays the results during the test.

    If desired, the ARGUS will save the test results (even if thetest is aborted) together with the date and time in its internalFlash memory.

    The saved results can later be sent to a PC or viewed on thedisplay.

    Access mode Single Tests

    STU-C 2-wireThe ARGUS simulates thenetwork side of the SHDSLconnection(central office)

    - SHDSL test- Bit error test- Connection

    STU-R 2-wire/PRIConnection of the ARGUS to

    the SHDSL access (using theDSL jack) or to the PRI network(e.g. connection to a PBXsystem using the Line jack).The ARGUS replaces theSHDSL modem.

    - SHDSL test

    STU-R 2-wireThe ARGUS simulates the userside of the SHDSL connection(remote).

    - SHDSL test- Bit error test- Connection

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    64/204

    10 SHDSL Tests

    64 ARGUS 28

    10.1 - SHDSL Line Test

    The ARGUS is connected directly to the SHDSL access viathe SHDSL 2-wire connection cable.

    Setting the access mode:

    In the Main menu, use the< ↓ > to select the Accessmenu.

    Open the Access menu

    Using the < ↓ >, selectSHDSL .

    The Access mode menu willopen automatically.

    Black 2-wireconnection cableRJ45 - RJ11 cable

    JackDSL

    SHDSLAccess

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    65/204

    10 SHDSL Tests

    65ARGUS 28

    Use < ↓ > to select thedesired Access mode (STU-C 2-wire , STU-R 2-wire orSTU-R/PRI) .

    The ARGUS will open theStatus display

    The ARGUS will display theselected access mode (in theexample: STU-R 2-wire) andthe supply voltage on theSHDSL line.

    If the ARGUS is not yet active, you must firstselect a test and start it.(see the next pages).

    If you press the < >, the ARGUS will return to theprevious display.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    66/204

    10 SHDSL Tests

    66 ARGUS 28

    In the SHDSL line test, the ARGUS first sets up a SHDSLconnection and then determines all the relevantperformance parameters.The ARGUS displays the performance parameters duringthe test and saves them in the internal FLASH memorywhen the test is finished or aborted.

    Parameter settings:The following parameters can be configured for the test (seePage 161):SHDSL parameter : Spectrum, Clock/framing, Channelselection, Power back off and EOC using

    The ARGUSStatus display

    Press Menu to open theMain menu or to begin the SHDSL linetest

    Using the < ↓ > , selectthe Single tests menu.

    Open the Single testsmenu

    Using the< ↓ > , selectSHDSL test .

    Initialisation of theSHDSL software

    The ARGUSsynchronises itself withthe remote end (in theexample, with STU-C).

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    67/204

    10 SHDSL Tests

    67ARGUS 28

    The ARGUS will setup aSHDSL connection anddisplay the associated"states“ and bit rate.

    In the event ofsynchronisation problems,"no. comm. mode" will bedisplayed.In this case, check theSHDSL parameters in regardto synchronisation with theremote end (see Page 161)Press < ABORT > to cancelthe setup of the connection.

    The SHDSL connection issetup.

    Use the : toscroll through. The ARGUSdisplays the bit rate, the Band Z-channels, the rep.count and the voltage on theSHDSL line.Press < TM > to open theTest Manager; you can thenstart a bit error test or setup aconnection, see “TestManager” on page 137

    Display of the performanceparameters

    etc. ......

    -Key

    -Key

    -Key

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    68/204

    10 SHDSL Tests

    68 ARGUS 28

    Display of the performance parameters

    The ARGUS displays the SHDSL line's performanceparameters for the remote end (R) and the central office end(C) (see "SHDSL Span" in the illustration below) and foreach SHDSL line segment (see "SHDSL Segment" in theillustration below); the parameter "EOC using" must be setto "on“ see Page 162.

    SNR Margin

    This value is given in dB andshows how much additionalnoise the transmission couldtake before the BER (BitError Rate) would exceed 10-7.

    Press < > to view theparameters of the next linesegment. The parametersshown are those for the linesegment currently indicatedin the top line.Press < > to scroll back.

    Use the -Key to scrollthrough the performanceparameters.Use the < TM > softkey to

    start the Test Manager (Page137).

    STU-R

    Network side =NCustomer side =C

    N C

    Intermediate repeaters 1 to a maximum

    N C N C N C

    STU-C

    SHDSLSegment SHDSLSegment SHDSLSegment

    SHDSL Span

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    69/204

    10 SHDSL Tests

    69ARGUS 28

    Attenuation (dB)Line attenuation in dB

    Power (dBm)power based on 1mW

    CRC CountCyclic Redundancy CheckCounter

    Number of CRC6 checksumerrors

    Loss of Sync DefectWord secondsNumber of faulty sync wordsper second

    Errored Second Count(ES Count)Number of errored seconds(seconds with CRC errors)

    Several Error SecondCount (SES Count)Number of seconds withmore than 50 CRC errors

    -Key

    -Key

    -Key

    -Key

    -Key

    -Key

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    70/204

    10 SHDSL Tests

    70 ARGUS 28

    Unavailable Second Count(US count)Number of seconds in whichno SHDSL connection wasavailable.

    Press < > to scroll to thedisplay of "SHDSL line 1"

    Press to have theARGUS save the result in thefirst available record in theFLASH memory (see“Automatic Tests” on page142).

    Storing the result

    Using the numeric keys enterthe name under which theresult should be saved(Default: AMP_1, AMP_2....or the call number of theaccess under test if thenumber has been enteredinto the speed-dialingmemory)Use the softkey on theright to shift the keypad (thesoftkey on the right assumesa different meaning whenpressed):< 12>ab > : entry of thedigits 0 to 9 plus * and #< ab>AB > : entry of thelowercase characters and @, /,- and . (e.g. to enter a "c“press the "2" on the keypadthree times)< AB>12 > : entry of theuppercase characters and@, /,- and .

    Use the ↑ ,↓ -Keys to movethe cursor to the right or left

    -Key

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    71/204

    10 SHDSL Tests

    71ARGUS 28

    Press < DEL > to delete thedigit before the cursor.

    -Key: Store result< ABORT >: Result not stored

    Press to start a newtest without reinitialising thesoftware and setting up theSHDSL connection again.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    72/204

    10 SHDSL Tests

    72 ARGUS 28

    10.2 Displaying the stored results(see “Automatic Tests” on page 142)

    In the Main menu, use the

    <↓> to select Automatictests .

    Use the < ↓ > -Key to selectthe record (e.g. AMP_2)holding the saved testresults.

    Use the < ↓ > to selectDisplay result .

    Display the test resultsUse the < ↓ > to scroll.

    Display the performanceparameters

    Close the results display.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    73/204

    10 SHDSL Tests

    73ARGUS 28

    10.3 Bit error test

    The bit error rate test (BERT = Bit Error Rate Test) servesto check the transmission quality of the access circuit.In the bit error test, the ARGUS sets up a SHDSL

    connection to a remote tester or places a call to itself, sendsa standardized (quasi-) random number string andcompares the received data with that which was sent.During the test, the ARGUS counts the bit errors and afterthe test is done it calculates the bit error rate and otherparameters in accordance with the ITU guidelines G.821and G.826.Normally, the bit error rate during a 1 minute test should beless than 10-7.

    However, if the test shows a higher bit error rate, it shouldbe repeated with a measurement time of 15 minutes toincrease its statistical precision.

    The BERT can be performed in different ways:

    BERT with a loopbox

    A loopbox (e.g., another member of the ARGUS familyof testers at the remote end) is required.

    BERT end-to-end

    This test requires a waiting remote tester such as anARGUS in theBERT wait mode . A bit pattern is sent tothis tester.

    Independent of the received bit pattern, the remotetester uses the same algorithm to generate a bit-patternthat it sends back.

    Therefore, both directions are tested independently.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    74/204

    10 SHDSL Tests

    74 ARGUS 28

    10.3.1 BERT start

    The following parameters are required for the BERT:- SHDSL parameter- BERT parameters:

    Duration of the BERT (default setting = 1 minute)Error level : If the bit error rate is greater than theerror level value, the ARGUS will display a NO inthe test result. If the bit error rate is less than theerror level value, the ARGUS will display an OK(default setting 10-06 )HRX value in % (hypothetical reference connectionsee ITU-T G.821) (default setting = 15%)Bit pattern , which will be sent during the test

    (default setting = 215-1)

    The ARGUS in theStatus display

    The ARGUS returns to theMain menu.

    Press < ↓ > to selectSingle tests

    Open the Single tests menu

    Press < ↓ > to select theBit error test

    Initialisation of the SHDSLsoftware(if the SHDSL connectionhas not already been setup)

    The ARGUS synchronisesitself with the remote end (inthe example, with STU-C)and sets up the SHDSLconnection(if the SHDSL connectionhas not already been setup)

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    75/204

    10 SHDSL Tests

    75ARGUS 28

    The ARGUS displays theavailable channels.

    Selection of the B-channelsused in the BERT.

    Start BERTAfter the ARGUS has setupthe connection andsynchronized the send andreceive directions, it willdisplay the bit pattern (e.g.2^15), the data rate (e.g.2312kB) , the remaining test

    time in h:min:sec, thenumber of bit errors thathave occurred (e.g. 0), thesynchronicity of the bitpattern (synchronous orasynchronous) and the LOS-counter.

    If you press < ERROR >, the ARGUS will generate anartificial bit error, which can be used to test the reliability of

    the measurement (in particular for end-to-end tests).

    Press < TM > to start the Test Manager (see “Test Manager”on page 137 )

    Press < ABORT > to stop the BERT.

    0 -Key: Restarts the bit error test. The test time and numberof bit errors will be reset.

    When a bit error is detected, this will be signaledby a brief alarm; in the event that thesynchronisation is lost, a constant alarm will sound(see “Alarm bell” on page 184).

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    76/204

    10 SHDSL Tests

    76 ARGUS 28

    The test results display:The bit pattern (e.g. 2^15),The data rate in kBits (e.g.2312 kB), the transferreddata in kBits (e.g. 10309 Kb)The number of bit errors(e.g.10),The bit error rate (e.g. 9.7E-07 = 9.7·10-7 = 0.00000097),The evaluation of the resultsdepends on the errorthreshold (OK).< MENU>: The ARGUSreturns to the BERT menu.

    Display of other charac-teristic values (in accordancewith ITU-T G.821/G.826)All values are given inpercentages.The ARGUS evaluateswhether the test resultssatisfy the limits specified inthe CCITT G.821/G.826under consideration of thedefined hypothetical

    reference connection (HRX).(see Page 96).↓ -Key: Scroll

    BERT - saving the result

    The ARGUS will save theresult in the first availablerecord in the FLASH memory

    (see “Automatic Tests” onpage 142).

    Save the test resultssee Page 70

    -Key

    -Key

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    77/204

    10 SHDSL Tests

    77ARGUS 28

    Another test can be startedwithout reinitializing theSHDSL test software andsetting up the SHDSLconnection again.

    Displaying the saved test resultssee “Displaying the stored results” on page 72

    Note: kBit = Bit*1000 KBit = Bit* 1024

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    78/204

    10 SHDSL Tests

    78 ARGUS 28

    10.3.2 BERT wait

    In BERT wait mode, the ARGUS will wait for the BERT atthe remote end which is necessary for an end-to-end test:

    In the Single tests menu,use the < ↓ > to selectBit error test .

    Open the Bit error test menu

    Using the < ↓ >, selectBERT wait .

    Activate "BERT wait“

    Using< ERROR > artificiallygenerate a bit error.Press < ABORT > to stop theBERT.

    After the test period haselapsed, the ARGUS willdisplay the result of theBERT.

    Press < TM > to start theTest Manager (Page 137)

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    79/204

    10 SHDSL Tests

    79ARGUS 28

    10.3.3 B-channel loop

    B-channel loop mode is required in order to run a bit errortest using a loopbox. All B-channels and Z-channels will belooped back.

    Activate loopbox

    The ARGUS will display theamount of time (h:min:sec)

    that the loopbox has beenactive.

    Loopboxstop

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    80/204

    10 SHDSL Tests

    80 ARGUS 28

    10.4 Telephony on permanent circuits

    To test a permanent circuit, you can simply call the oppositeend using a selected B-channel. Both ends of thepermanent circuit must use the same B-channel.

    The SHDSL parameter channel selection (seePage 162 ) may only be set to "auto “, when theremote end sets the data rate.

    A connection can only be setup at data rates lessthan or equal to 2048 kBits, i.e. the channelselection parameter may be set to a maximum of32 B-channels.

    Use < ↓ > to selectPhone / connec. in theSingle test menu

    or press the -Key.

    Use the ↓ ,↑ - keys to scrollthrough the availablechannels and to select one .

    Setup a permanent switch

    The ARGUS displays the B-channel used (e.g. B01) andthe duration of thepermanent circuit.Use the < TM > softkey tostart the Test Manager(see “Test Manager” on page

    137)Terminate permanentcircuit

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    81/204

    11 Single Tests

    81ARGUS 28

    11 Single Tests

    11.1 Test the Supplementary Services

    The ARGUS checks whether the access under test supportssupplementary services in 1TR6 or DSS1 protocol.

    11.1.1 Suppl. Services Test on 1TR6

    (only BRI or U-Interface)

    Using the < ↓ > in the Mainmenu, select the Singletests menu.

    The Single tests menuopens

    Using the < ↓ > , selectSupp.serv.test .

    Start test

    The test is running.

    The test results aredisplayed automatically:+ = suppl. servicesupported- = suppl. service notsupportedUse < ↓ > to scroll through

    the test results

    Sperre Blocking enabled for outgoing calls

    AWS1 Call forwarding type 1 enabled (continuous)

    AWS2 Call forwarding type 2 enabled (case by case)

    AnschlussGBG

    Access belongs to a Closed Users Group

    The ARGUS will return tothe

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    82/204

    11 Single Tests

    82 ARGUS 28

    Geb.anzeige Advice of charge

    Rufnummern-Id

    Setup call number identifier - againstmalicious calls

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    83/204

    11 Single Tests

    83ARGUS 28

    11.1.2 Suppl.service interrogation in DSS1

    In the Single tests menu,using the < ↓ >, selectSupp.serv.test .

    Open the enter Numbersdialogue

    Use the keypad to enter the"Own number" (the numberof the access under test)(see “Saving Call Numbers”on page 185.). The ARGUSwill test the availability of thesupplementary service (in

    part by placing a call toitself).

    Using the < ↓ >, select theservice which should beused for the supplementaryservices test.

    Confirm the service.

    Enter the B-channel on thekeypad. By default, thechannel last used will besuggested. If you enter an *,the ARGUS will choose anyB-channel that is free.

    Confirm the B-channel

    Use the < ↓ > to select thesupplementary service (e.g.TP) that you want theARGUS to check whether itis supported on the accessunder test.

    Start test

    The ARGUS will display theresults of the test once it isdone:

    + = suppl. service supported- = suppl. service not supportedUse the < ↓ > to scroll through the test results.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    84/204

    11 Single Tests

    84 ARGUS 28

    If you press the < > , the ARGUS will return to theprevious display (this applies for all displays).

    Test Comments

    TP The ARGUS tests theTP (Terminal Portability)supplementary service by making a self call.

    HOLD The ARGUS tests the HOLD supplementaryservice by making a self call.

    CLIP

    (CLIP, CLIR, COLP, COLR )

    In this test, the ARGUS checks whether the 4supplementary services CLIP ,CLIR , COLP andCOLR are supported. To do so, the ARGUSwill setup as many as three calls to itself.CLIP : Will the calling subscriber's number be

    displayed at the called subscriber?(t = CLIP temporarily availablep = CLIP permanently available)CLIR: Will the display of the callingsubscriber's number at the called subscriber besuppressed or is it possible to temporarilysuppress the display?If the ARGUS displays an*, it is not possible todetermine the availability of the service, sinceno CLIP has been setup.

    (t = CLIR temporarily availablep = CLIR permanently available)COLP: Will the call number of the subscriberwho answered be displayed on the caller'sphone?COLR: Will the display of the call number ofthe subscriber who answered be suppressedon the caller's phone or is it possible totemporarily suppress the display?If the ARGUS displays an*, it is not possible todetermine the availability of the service, sinceno COLP has been setup.

    The suppl. services pairs CLIP and CLIR aswell as COLP and COLR will be tested. If CLIRor COLR is setup permanently, it is notpossible to make a clear assessment.

    DDI Can a caller directly dial in to an extension onthe PBX access under test?

    MSN Is the supplemental service MSN available?

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    85/204

    11 Single Tests

    85ARGUS 28

    CF

    (CFU, CFB,CFNR)

    In this test, the ARGUS checks the 3supplementary services CFU , CFB and CFNRone after the other to determine whether theyare supported on the access under test.CFU: Can this access immediately forward anincoming call?CFB: Can this access forward an incoming callwhen it is busy; in other words does it supportCall Forwarding Busy?CFNR: Can this access forward an incomingcall when it is not answered?The CF test attempts to setup a call diversionto the call number that is in the memorylocation for “remote call number 1” (see“Saving Call Numbers” on page 185). The CFtest cannot be performed, if this location doesnot contain a valid call number to which it ispossible to divert a call.

    CW Does the access under test support callwaiting?

    CCBS /CCBS-T(on a P-P

    access)

    Will the access under test automatically recalla remote subscriber, if the number called wasbusy?

    CCNR/CCNR-T(on a P-Paccess)

    Will the access under test automatically recalla remote subscriber if the call was notanswered?

    MCID Does the access tested allow identification ofmalicious callers (call tracing)?

    3pty Does the access under test support a three-

    party conference call?For this test, you need the assistance of aremote subscriber, whose call number must beentered.

    ECT Is an explicit call transfer supported by theaccess under test?For this test, you need the assistance of aremote subscriber, whose call number must beentered.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    86/204

    11 Single Tests

    86 ARGUS 28

    AOC The ARGUS checks whether the charges canbe sent to the access under test. The test usesa call to oneself to check both AOC-D (AOCduring a call) and AOC-E (AOC at the end of acall).

    SUB A call is made to oneself and answered tocheck the transfer of the sub-address in bothdirections.Are sub-addresses supported on the accessunder test?

    UUS Does the access under test support thetransfer of user data?

    CUG The ARGUS then uses a self call to check

    whether the access under test belongs to aclosed user group.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    87/204

    11 Single Tests

    87ARGUS 28

    11.1.3 Suppl. Services Tests – Error messages

    If an error occurs during theSupplementary ServicesTests or if it is not possible tosetup a call, the ARGUS willdisplay the correspondingerror code (e.g. 28).Use < ↓ > to scroll through.

    In the example, the error belongs to the error class "wrongor invalid number".In the table below, you will find that this is an error from thenetwork and that it reports that the call number wasincomplete or in the wrong call number format (see“CAUSE-Messages – DSS1 Protocol” on page 198.).

    Distributing the error codes into error classes:

    For further information regarding error codes:“ARGUS ErrorMessages” on page 202, “CAUSE-Messages – DSS1Protocol” on page 198 and “CAUSE-Messages – 1TR6Protocol” on page 200.

    Errorclass

    Description Cause (fromnetwork)1 TR6 DSS1

    CauseARGUSinternal

    A No or anotheraccess

    __ __ 201,204,205,210,220

    B Wrong or invalidnumber

    53, 56 1,2,3,18,2122,28,88

    152,161,162,199

    C One or moreB-channels busy

    10,33,59 17,34,47 ___

    D Wrong service 3 49,57,58,6365,70,79 ___

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    88/204

    11 Single Tests

    88 ARGUS 28

    11.2 Service check

    The ARGUS checks, which of the following services aresupported by the access under test:

    The test runs automatically.

    For each service, the ARGUS will place a call to itself (to theaccess under test). However, the call will not be answeredso no charges will be incurred.

    Service Name in theARGUS display /abbreviation

    Language Language / LangUnrestricted DigitalInformation

    UDI 64kBit / UDI 64

    3.1 kHz Audio Tel.analog / Tel.7 kHz Audio 7 kHz audio / 7 kHzUnrestricted DigitalInformation with tones /

    Display

    UDI+TA / UDI TA

    Telephony Tel.ISDN / Tel.Facsimile Group 2/3 Fax G3 / FaxG3Facsimile Group 4 Class 1 Fax G4 / FaxG4Teletex service basis andmixed mode and facsimileservice Group 4 Classes IIand III

    Mixed Mode / Mixed

    Teletex Service basis

    mode

    Teletex / Ttx64

    International inter workingfor Videotex

    Videotex

    Telex TelexOSI application accordingto X.200

    OSI

    7 kHz Telephony Tel.7kHz / Tel7kVideo Telephony,first connection

    Videotel.1 / Vid.1

    Video Telephony,second connection

    Videotel.2 / Vid.2

    Three user-specificServices(see “Services” on page168.)

    Userspec.1 /Userspec.2 /Userspec.3 /

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    89/204

    11 Single Tests

    89ARGUS 28

    In the Single tests menu,use < ↓ > to select Servicetest.Open the enter NumbersdialogueEnter the Own number ofthe access under test

    There are PBXs that use separate call numbers forincoming and outgoing calls.In this case, for the Service checks, you can enter

    a “remote” call number that corresponds to the“own” number that is not stored in the ARGUS.

    If the Service check should extend outside of thelocal exchange, it is possible to perform the

    Service check in anend-to-end mode .In this case, you must enter the remote call number for asecond terminal device.The ARGUS will then automatically check whether the

    remote terminal can accept the call under the variousservices – in other words, whether it is “compatible” withthese services.

    In the test results, the second part (second +, - or *) refers tothe answer from the remote exchange.

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    90/204

    11 Single Tests

    90 ARGUS 28

    The ARGUS will display theresults of the test once it isdone.Use the < ↓ > to scrollthrough the test results.The ARGUS makes adistinction between outgoingcalls (the first +, - or *) andincoming calls (the second+, - or *).+ = Service supported- = Service not supported* A definite statement cannotbe given due to the adjacenterror code.

    Interpreting the testresults:

    Displayed Description

    + + The self call functions OK or the remote end cantake the call for this service

    + - Call was sent successfully, however, it was rejectedon the remote end due to missing authorization.(Error class D in a B-channel message e.g. in aSETUP_ACK or CALL_SENT)

    - An outgoing call with this service is not possible(Error class D without a B-channel message)

    + * Call was sent successfully, the call back or call tothe remote end failed (e.g., remote end busy or noB-channel available for the call back).(Error class B, C or E in a B-channel

    message)* Wrong number, no B-channel available or other

    error(Error class B, C or E without a B-channel message)

    If the outgoing call is not successful, it isnot possible tomake a statement about an incoming call. Therefore, youwill never see “- +” or “- *” on the display.

    Test results:

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00

    91/204

    11 Single Tests

    91ARGUS 28

    For outgoing, the Fax G4service is OK. No statementis possible about incoming.The error code 63 indicatesthe cause of the error whichhas occurred(see tables in appendix).In this case, it isrecommended that you havesomeone place a call to theaccess under test using thisservice.The Mixed Mode service ispossible in both directions.

    If an error of error class A occurs (see “Suppl. Services

    Tests – Error messages” on page 87.) the Service test willbe aborted.

    An error of any other error class will coded in decimal (in theexample above 63), assigned to the respective service andthen displayed.

    Example:

  • 8/15/2019 02_ARGUS 28_Manual_U_V_3_00