    Section 01500 - Temporary Facilities

    Part 1 - General

    1.01 Related Documents

    A. Contract General Conditions.

    B. (TO BE PROVIDED BY THE ARCHITECT AS REQUIRED)

    1.02 Summary

    A. This Section speciies re!uirements or temporary ser"ices and acilities# includin$utilities# construction and support acilities# security and protection.

    B. Temporary utilities that are re!uired include %ut are not limited to&

    (CAMPUS TO PROVIDE PROJECT-SPECIFIC INFORMATION)

    'ater ser"ice and distri%utionTemporary electric po(er and li$htTelephone ser"ice.

    C. Temporary construction and support acilities that are re!uired include %ut are notlimited to&

    Temporary heat)ield oices and stora$e sheds

    Temporary enclosures*oists and temporary ele"ator use'aste disposal ser"icesConstruction aids and miscellaneous ser"ices and acilities.Temporary )acilities or the +(ner,s se.(TRUSTEES AND CAMPUS TO PROVIDE PROJECT-SPECIFICINFORMATION)

    D. Security and protection acilities that are re!uired include %ut are not limited to&

    Temporary ire protectionBarricades# (arnin$ si$ns# li$htsn"ironmental protection.

    1.0/ Su%mittals

    A. Temporary tilities& Su%mit reports o tests# inspections# applica%le meterreadin$s and similar procedures perormed on temporary utilities.

    Section 0100 - 1Re". 3045

  • 7/25/2019 01500 Temp Facilities

    2/7

    1.04 6uality Assurance

    A. Re$ulations& Comply (ith industry standards and applica%le la(s and re$ulationso the authorities ha"in$ 7urisdiction# includin$ %ut not limited to&

    Cal +S*ABuildin$ Code re!uirements*ealth and saety re$ulationstility company re$ulationsPolice# )ire Department and Rescue S!uad rulesn"ironmental protection re$ulations.

    B. Standards& Comply (ith 8)PA Code 241# 9Buildin$ Construction and Demolition+perations9# A8S:-A10 Series standards or 9Saety Re!uirements orConstruction and Demolition9# and 8CA lectrical Desi$n ;i%rary# 9Temporarylectrical )acilities.9

    1. Reer to 9Guidelines or Bid Conditions or Temporary

  • 7/25/2019 01500 Temp Facilities

    3/7

    unsae conditions or "iolate re!uirements o applica%le codes and standards.

    B. Pro"ide 11-$au$e# $al"ani@ed 2-inch# chain lin? a%ric encin$ -eet hi$h (ith$al"ani@ed steel pipe posts# 1-1329 :.D. or line posts and 2-1329 :.D. or cornerposts.

    2.02 !uipment

    A. General& Pro"ide ne( e!uipment or# i accepta%le to the Trustees# Contractor maypro"ide undama$ed# pre"iously used e!uipment in ser"icea%le condition. Pro"idee!uipment suita%le or use intended.

    B. )irst Aid Supplies& Comply (ith $o"ernin$ re$ulations.

    C. )ire tin$uishers& Pro"ide hand-carried# porta%le ;-rated# class 9A9 ireetin$uishers or temporary oices and similar spaces. :n other locations pro"ide

    hand-carried# porta%le# ;- rated# class 9ABC9 dry chemical etin$uishers# or acom%ination o etin$uishers o 8)PA recommended classes or the eposures.

    Comply (ith 8)PA 10 and 241 or classiication# etin$uishin$ a$ent and si@ere!uired %y location and class o ire eposure.

    2.0/ Temporary )ield +ice or +(ner,s se (DETAILS LISTED ARE MINIMUMAND MUST BE MADE PROJECT-SPECIFIC)

    A. Pro"ide a trailer# construct a separate ield oice %uildin$# or use eistin$ %uildin$s

    i so desi$nated on the Contract Documents# or the eclusi"e use o the +(ner,sRepresentati"es ully e!uipped and ready or use (ithin se"en 5 days o the8otice to Proceed. The ield oice# i a trailer# and its appurtenances oraccessories shall remain the property o the Contractor.

    B. Buildin$ shall %e o (eather ti$ht construction and contain a minimum o /0s!uare eet# 12 t. /0 t.5# o loor space. Pro"ide -oot minimum ceilin$hei$ht. Pro"ide one separate oice minimum 120 s!uare eet each5# a(or?room3meetin$ room minimum 240 s!uare eet5. A septic tan? or porta%letoilet or the EC;S:F use o the Trustees may %e pro"ided i no se(erconnection is a"aila%le. Pro"ide loor-to-ceilin$ (alls to separate the rooms do notuse temporary partitions. Pro"ide interconnectin$ loors.

    C. Pro"ide at least si (indo(s (ith security %ars in the %uildin$# (ith at least one(indo( or each room. Pro"ide %linds or (indo(s. Pro"ide t(o entrance doorsto the %uildin$# one at each end. Pro"ide cylinder loc?# and dead %olt and ?ey oneach door. Pro"ide t(o sets o ?eys to the Pro7ect =ana$er or Construction:nspector.

    D. ;ine (alls and ceilin$ (ith insulation.

    Section 0100 - /Re". 3045

  • 7/25/2019 01500 Temp Facilities

    4/7

    . Pro"ide reri$erated air conditionin$. Pro"ide heatin$ system. *FAC system shallmaintain a temperature indoors o ) to 0)# re$ardless o outdoor conditionsat the site.

    ). Pro"ide hot (ater# i a"aila%le5# and cold (ater# electricity# and telephone ser"ice(ith t(o lines. Pro"ide at least one telephone in each oice. Pro"ide %ottleddrin?in$ (ater ser"ice (ith hot and cold dispenser.

    G. Pro"ide 7anitorial ser"ice (ith one cleanin$ per (ee?.

    *. Pay the costs or electrical ser"ice. Pay telephone installation cost and monthlyser"ice char$e or the all lines. The Contractor shall pay or all telephone calls.

    2.04 Accessory !uipment

    A. )or each oice&

    1. +ne /, , des? (ith dra(ers and loc?s2. +ne cushioned oice s(i"el chair or des?/. T(o cushioned chairs or "isitors4. +ne metal ilin$ ca%inet# 19' /09D 29*# our dra(ers (ith

    loc?s. +ne %oo?case# 129D 49;# (ith one 12-inch-hi$h shel and one

    1-inch-hi$h shel. +ne (aste%as?et. +ne plan rac?# (ith si metal stic?iles.

    B. )or the (or?room&1. T(o 4, , lat ta%les (ith t(o cushioned chairs each.

    2. T(o (aste%as?ets/. +ne metal ilin$ ca%inet# 19' /09D 29*# our dra(ers (ith

    loc?s4. +ne plan rac?# (ith i"e metal stic?iles. +ne (all-mounted mar?er %oard# 4, 4, minimum# (ith three

    mar?ers each in colors red# $reen# %lue# and %lac?.. +ne (all-mounted cor? %oard or thum%tac?s# 4, 4, minimum.. Plain paper# pro$ramma%le hi$h speed a (ith dedicated phone

    line.. Computers (ith laser-!uality printer and sot(are .(OPTIONAL - TO BE

    MADE PROJECT SPECIFIC)H. Copy machine& =inolta model 400 or Canon model 400 or e!ual.

    Contractor to pro"ide paper# toner# and all re!uired supplies to operatecopy machine.

    All e!uipment is to %e 8'# +R ;:>8'. sed and3or re%uilt e!uipment isC+8D:T:+8A;;I ACCPTAB; PR+F:DD :T :S STAT-+)-T*-ART A8D D+S8+TEPR:8CECSS:FBRA>D+'8S# A8+TAG+)=+RT*A8T'+T:=S:8+8 =+8T*+8 T*SA=P:C+) 6:P=8T :SC+8S:DRDECSS:F5. TheContractor shall maintain or replace ailed or malunctionin$ e!uipment (ithin 4-

    Section 0100 - 4Re". 3045

  • 7/25/2019 01500 Temp Facilities

    5/7

    hours as directed %y the Trustees or the Trustees reser"e the ri$ht to lease3purchasereplacement e!uipment at the Contractor,s epense.

    2.0 lectrical +utlets and ;inin$s

    A. Pro"ide (arm (hite luorescent li$ht itures to e"enly illuminate the rooms to aminimum o 0 oot-candles and an a"era$e o 0 oot-candles measured at des?hei$ht. Pro"ide a minimum 0-(att li$ht iture in the la"atory acility. Pro"ideli$ht s(itch in each room.

    B. Pro"ide t(o duple 120-"olt outlets in each room one only in restroom5.

    2.0 Ser"ice Contracts

    A. 'ee?ly 7anitorial ser"ice to include trash remo"al# loor cleanin$ and dustin$. :n

    addition# the Contractor shall maintain the approach to the ield oice ree rommud and (ater. lectrical ser"ice shall consist o a minimum o 4 circuit# 110 "olt#0 amp ser"ice.

    Part / - ecution

    /.01 :nstallation

    A. se !ualiied personnel or installation o temporary acilities. ;ocate acilities(here they (ill ser"e the Pro7ect ade!uately and result in minimum intererence

    (ith perormance o the 'or?. Relocate and modiy acilities as re!uired.

    B. Pro"ide each acility ready or use (hen needed to a"oid delay. =aintain andmodiy as re!uired. Do not remo"e until acilities are no lon$er needed# or arereplaced %y authori@ed use o completed permanent acilities.

    /.02 Temporary tility :nstallation

    A. General& n$a$e the appropriate local utility company or personnel to installtemporary ser"ice or connect to eistin$ ser"ice.

    se Char$es& Cost or use char$es or temporary acilities are the Contractor,sresponsi%ility.

    B. 'ater Ser"ice& 'ater may %e ta?en rom the ni"ersity,s systems in such!uantities and at such times as they are a"aila%le. : this is done# pro"ide alltemporary materials necessary to etendin$ the utility to (here they (ill %e used.Contractor to install a meter and reim%urse the ni"ersity or any (ater used.

    Section 0100 - Re". 3045

  • 7/25/2019 01500 Temp Facilities

    6/7

    C. Temporary lectric Po(er Ser"ice& lectricity may %e ta?en rom the ni"ersity,ssystem i a"aila%le. : this is done# pro"ide all e!uipment# includin$ connections#and other materials necessary or etendin$ the utility lines to (here they (ill %eused. Coordinate the installation (ith the Trustees Representati"e. Contractor toinstall a meter and reim%urse the ni"ersity or any po(er used. 'here su%-meterin$ is not possi%le or practical# a lat ee may %e esta%lished and paid to theni"ersity.1. 'hen not a"aila%le rom the ni"ersity# the Contractor must arran$e and

    pay or electric ser"ice throu$h the local utility or urnish his o(n porta%lepo(er.

    2. All permanent po(er used %y the Contractor prior to +ccupancy %y theTrustees shall %e metered and paid or %y the Contractor.

    D. Temporary Telephones& Contractor shall ha"e telephone acility a"aila%le at its%usiness oice or the duration o contract (here the Contractor and itssuperintendent may %e contacted. A pay phone or use o su%contractors isrecommended.

    . Temporary )ire Protection& ntil ire protection needs are supplied %y permanentacilities# install and maintain temporary ire protection acilities o the typesneeded to protect a$ainst reasona%ly predicta%le and controlla%le ire losses.Comply (ith 8)PA 10 9Standard or Porta%le )ire tin$uishers#9 and 8)PA 2419Standard or Sae$uardin$ Construction# Alterations and Demolition +perations.9

    1. ;ocate ire etin$uishers (here con"enient and eecti"e or their intendedpurpose# %ut not less than one etin$uisher on each loor at or near eachusa%le stair(ell.

    2. Store com%usti%le materials in containers in ire-sae locations.

    /. =aintain uno%structed access to ire etin$uishers# ire hydrants# temporaryire protection acilities# stair(ays and other access routes or i$htin$ ires.Prohi%it smo?in$ in ha@ardous ire eposure areas.

    4. Pro"ide super"ision o (eldin$ operations# com%ustion type temporaryheatin$ units# and similar sources o ire i$nition.

    ). Barricades# 'arnin$ Si$ns and ;i$hts& Comply (ith standards and codere!uirements or erection o structurally ade!uate %arricades. Paint (ithappropriate colors# $raphics and (arnin$ si$ns to inorm personnel and the pu%lico the ha@ard %ein$ protected a$ainst. 'here appropriate and needed pro"ideli$htin$# includin$ lashin$ red or am%er li$hts.

    G. Security nclosure and ;oc?up& :nstall su%stantial temporary enclosure opartially completed areas o construction. Pro"ide loc?in$ entrances to pre"entunauthori@ed entrance# "andalism# thet and similar "iolations o security.

    Stora$e& 'here materials and e!uipment must %e stored# and are o "alue orattracti"e or thet# pro"ide a secure loc?up. norce discipline in connection (iththe installation and release o material to minimi@e the opportunity or thet and"andalism.

    Section 0100 - Re". 3045

  • 7/25/2019 01500 Temp Facilities

    7/7

    *. n"ironmental Protection& Pro"ide protection# operate temporary acilities andconduct construction in (ays and %y methods that comply (ith en"ironmentalre$ulations# and minimi@e the possi%ility that air# (ater(ays and su%soil mi$ht %econtaminated or polluted# or that other undesira%le eects mi$ht result. A"oid useo tools and e!uipment that produce harmul noise. Restrict use o noise ma?in$tools and e!uipment to hours that (ill minimi@e complaints rom persons or irmsnear the site.