Automatic transfer switches ATK series Planet-SWITCH Planet-SWITCH Planet-SWITCH Planet-SWITCH Planet-SWITCH Planet-SWITCH Planet-DIN Planet-LOGIC Planet-DIN Planet-LOGIC Planet-DIN Planet-LOGIC Planet-DIN Planet-LOGIC Planet-DIN Planet-LOGIC Planet-DIN Planet-LOGIC

005.- Catálogo Transfer Automatica Lobato

Embed Size (px)

DESCRIPTION

catalogo automatica

Citation preview

Page 1: 005.- Catálogo Transfer Automatica Lobato

AutomatictransferswitchesATK series

Planet-SWITCHPlanet-SWITCHPlanet-SWITCHPlanet-SWITCHPlanet-SWITCHPlanet-SWITCH

Planet-DIN

Planet-LOGIC

Planet-DIN

Planet-LOGIC

Planet-DIN

Planet-LOGIC

Planet-DIN

Planet-LOGIC

Planet-DIN

Planet-LOGIC

Planet-DIN

Planet-LOGIC

Page 2: 005.- Catálogo Transfer Automatica Lobato

General characteristicsThe automatic transfer switch “ATK” is used for theautomatic changeover of the load from the “main line” toa “secondary line”.It is made of a single unit in an insulated housing andhas two outgoings for the “automatic” and/or “manual”control of contactors or circuit breakers.MANUAL CHANGEOVERThis mode consents to the manual changeover from onesource to another and viceversa.AUTOMATIC CHANGEOVERThis mode automatically enables the switching of twolines within a time period, adjustable between 0.5 and120 seconds.The control of the two line contactors or circuit breakersis achieved in a safe and reliable manner by means of asafety system with internal electromechanical interlockof the ATK unit.

Operational characteristics– Rated supply voltage: 24VDC (ATK20) -

230VAC (ATK40)– Voltage range: 0.7-1.35% Us (ATK20)

0.8-1.2% Us (ATK40)– Maximum current consumption: 250mA (ATK20) -

45mA (ATK40)– Rated current: 100mA (ATK20) - 35mA (ATK40)– Connection time: 100%– Maximum voltage ripple: 10% (ATK20)– Power loss ride through (MPU circuit): ≥300ms– Galvanic isolation between control network and

internal circuits– True RMS control of supplt voltage– Microprocessor supervision of functions– Membrane keypad and 3 digit display– 11 signalling LEDs– Adjustable tripping limits and time– AUT-MAN-TEST operating mode– 1 “Main” L-L voltage measurement input– 1 “Secondary” L-L voltage measurement input– 100-415VAC rated voltage control– 70-500VAC L-L voltage range– 50 or 60Hz rated frequency– Full scale measurement accuracy: ±1% ±1digit– 2 output relays (16A Ith changeover contact) for “Main”

and “Secondary” contactor or circuit breaker control– 1 alarm output relay (8A Ith changeover contact)– IP41 on front, IP54 with sealable cover (order

separately)– IP20 at rear.

Set upThe set up contemplates the following setting parameters:– Max voltage limit for “Main” and “Secondary” lines– Min voltage limit for “Main” and “Secondary” lines– Min-Max limit tripping delay for “Main” and

“Secondary” lines– Min-Max limit delay at voltage return for “Main” and

“Secondary” lines– Changeover/interlock control time for circuit breakers

control of “Main” and “Secondary” lines.

Selling points– Microprocessor supervision– Easy and simple installation– RMS voltage measurements (full scale accuracy: ±1%

±1digit)

Reference standardsCompliant with standards: IEC/EN50081-1,IEC/EN50082-2, IEC/EN61010-1, IEC/EN60068-2-6,IEC/EN60068-2-27, IEC/EN60529, IEC/EN61000-4-11and EN50011.

Order code Description Qty Wtperpkgn° [kg]

ATK20 Automatic transfer switch, 1 0.70024VDC auxiliary supply

ATK40 Automatic transfer switch, 1 0.900230VAC auxiliary supply

PACR IP54 front protection cover 1 0.107

Automatic transfer switches

PD39

GB

03 0

2

144

144

62

9

52

31

PACR

®

ATK

AUTOMATICTRANSFERSWITCH

AUT ON/OFF

MAIN LINE ON

SEC LINE ON

OPEN ALL LINES

TEST

SETUP

POWER ON

ALARM

LOAD

SECONDARYLINE

MAINLINE

DIMENSIONS (mm)

WIRING DIAGRAM

ATK...