HM-01
20100854.B70
09/11/2020
SILVER/PETRUCELLI + ASSOCIATES
HAZARDOUS MATERIALS ABATEMENT PLANMAIN ENTRANCE VESTIBULE RENOVATIONS
ORANGE AVENUE ELEMENTARY SCHOOL
MILFORD CONNECTICUT
?" = ??'
56 QUARRY ROADTRUMBULL, CONNECTICUT 06611203.374.3748www.fando.com
SEALSEAL
SCALE:
DATUM:
VERT.:
HORZ.:
VERT.:
HORZ.:
PROJ. No.:
DATE:
MS
V
IE
W:
LA
YE
R S
TA
TE
:
DATENo.DESCRIPTION
DESIGNER REVIEWER
File
P
ath
: F
:\P
20
10
\0
85
4\B
70
\D
ra
win
gs\C
AD
\H
M D
ra
win
gs.d
wg
L
ayo
ut: O
RA
NG
E P
lo
tte
d: F
ri, S
ep
te
mb
er 1
1, 2
02
0 - 1
2:5
2 P
M U
se
r: b
silve
rm
an
Plo
tte
r: D
WG
T
O P
DF
.P
C3
C
TB
F
ile
: F
&O
S
TA
ND
AR
D.C
TB
LEGEND
GENERAL NOTES
ASBESTOS ABATEMENT NOTES
EF-18x8
ECUH-1
14x10 TRANSFERDUCT.
T
REVERSE ACTINGTHERMOSTAT
ROSS TECHNOLOGY MAXIUM SECURTY LOUVERMODEL # DOS 60 MINUTE FE/BR, 36x12, ONE ONEACH WALL. COORDINATE COLOR AND LOCATIONWITH ARCHITECT.
8x8 UP TO 10x10 ROOF JACK.TRANSITION AS REQUIRED.COORDINATE ROOF JACKCOLOR WITH ARCHITECT
REMOTE SENSOR,3'-0" AFF
S
RELOCATE RECESSED HEATER2 FEET. AS REQUIRED. PROVIDE PIPING,CONTROL WIRING, PIPE INSULATION,PIPE SUPPORTS, CONDUITS, ETC ASREQUIRED FOR HEATERS TO BERELOCATED. TYP. OF 2. RE
RE
DRAWING NOTES
PROVIDE ALL OFF SETTING AS REQUIRED FOR DUCTWORK TOCLEAR ALL DEVICES, STRUCTURAL MEMBERS, ETC.
TRANSITION NEW DUCTS AT CONNECTIONS TO FANS, AIROUTLETS/INLETS TO MATCH CONNECTING SIZES.
ALL DUCTWORK SHALL BE SHEET METAL AND TO SMACNA STANDARDS.
PROVIDE FIRE DAMPERS IN ALL RATED WALLS, CONFIRM ALL WALL RATINGWITH ARCHITECTURAL.
FIRE DAMPERS SHALL BE MINIMUM ONE HOUR RATED UNLESS OTHERWISENOTED.
PROVIDE SLEEVES FOR ALL PENETRATIONS THRU WALLS. PACK WITH FIRECAULK FOR RATED WALLS.
THIS CONTRACTOR SHALL NOTE THAT FULLY COORDINATED DUCTWORKSHOP DRAWINGS MUST CLEARLY INDICATE ALL LIGHTING, PIPING CONDUIT,STRUCTURE ETC. EXACT ROUTING OF ALL DUCTWORK SUBJECT TOARCHITECT APPROVAL IN FIELD. REROUTE/RELOCATE AS REQUIRED TOCOORDINATE WITH OTHER TRADES AND FIT WITHIN BUILDING CONSTRAINS.
1.
2.
3.
4.
5.
6.
7.
AT OUTLET OF FANPROVIDE FLEXIBLE CONNECTION
FIBERGLASS DUCTWORK
2'-0" LONG FULL SIZEDISCHARGE DUCT WITH INTERNAL ACOUSTICLINING FABRICATE USING
VIBRATION ISOLATOR
RECOMMENDATIONSWITH MANUFACTURER'SSIZE IN ACCORDANCE
HANGER RODSFASTENED SECURELYTO STRUCTURE ABOVE
AIRFLOW
LONG RADIUS TEE
TAKE-OFF
SUPPLY DUCTS ONLYSUPPLY AND RETURN DUCTS
SQUARE ELBOW
LONG RADIUS TEE
RETURN DUCTS ONLY
AIRFLOW
TAKE-OFF
SUPPLY DUCTS ONLY
FULL RADIUS ELBOW
SUPPLY AND RETURN DUCTS
TYP. TURNING VANE
SUPPLY AND RETURN DUCTS
SUPPLY AND RETURN DUCTS
SQUARE ELBOW
AIRFLOW
SLOPE 1" IN 7"
AIRFLOW
DOUBLE THICKNESSTURNING VANES
3M-2
INLINE FAN SCALE: NTS
CEILING
EXHAUST GRILLE FROMFAN MANUFACTURER.
M-2Mechanical Plans,Details, Schedules MZ
CABINET UNIT HEATER SCHEDULE (ELECTRIC HEAT)ELECTRICALNOMINALTAG CFM V/Ø/Hz (KW)
TEMPERATURERISE (°F)
CAPACITY
ECUH -1 310 4.0 11.8INDEECO 208/3/60
MANUFACTURER MODEL
CDIR-937U04000D
REMARKS:
ELECTRIC HEAT
REMARKS
1,2,3,4,5
FLA
1. ALL UNITS SHALL BE INTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION.2. PROVIDE WITH FACTORY OPTIONS FOR THE TAMPERPROOF THERMOSTAT AND 3-POLE, 32 AMP DISCONNECT.3. FURNISH WITH SINGLE POINT POWER CONNECTION.4. COLOR CHOICE BY ARCHITECT.5. PROVIDE WITH FACTORY FURNISHED JUNCTION BOX AND FUSE.
41SYMBOL (IN. WG.)
PRESSSTATIC ELECTRICAL
RPMFAN
EF-1
(LBS)
EXHAUST FAN SCHEDULE
INTERLOCKEDWITH
REMARKS:1. PROVIDE WITH VARI-GREEN EC MOTOR WITH POTENTIOMETER MOUNTED DIAL AND DISCONNECT.2. PROVIDE WITH 10x10 ROOF JACK, PART NUMBER RJ-10x10.3. PROVIDE ALUMINUM GRILLE WITH WHITE ENAMEL FINISH.4. PROVIDE WITH HONEYWELL REVERSE-ACTING THERMOSTAT, PN 380044.5. PROVIDE WITH ISOLATION KIT, PN VI-KIT-SP/CSP6. PROVIDE WITH POLYPROPYLENE MATERIAL.
MODEL
TYPE CFM VOLTS PHASEWEIGHT
SONES REMARKSHP(WATTS)
WALL MOUNTED REVERSE ACTINGTHERMOSTAT AND REMOTE SENSOR 1,2,3,4,5,6SP-A510-VG CEILING 500 .375 120 11275 (155) 52 7.0
MANUFACTURER
GREENHECK
2M-2
TYPICAL DUCT DETAILS SCALE: NTS
1M-2
MECHANICAL FLOOR PART PLAN SCALE: 1/2" = 1'-0"
Drawing Title:
Tel. 203 230 9007 Fax. 203 230 82473190 Whitney Avenue, Hamden, CT 06518-2340
SILVER / PETRUCELLI + ASSOCIATES
silverpetrucelli.com
Architects / Engineers / Interior Designers
Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
Orange Avenue School Entrance Upgrades
Milford, Connecticut 06461
Milford Public Schools
260 Orange Avenue
AUGUST 27, 2020
AS NOTED
20.084State Project Number: 084-
MZ
ICNB
FAA
P
F
J
FAG
AP
J
PC
CR
FAC
P
KP
P
VD
C
SP
PIC
PIC
S
SC
DS
ER ER
ER ER
R
R
RRRR
RR
RRRR
RR
RR
RR
ERP
RR
RR
RRRR
RR
RR
ERP
ER
ER
RR
RRER
RR
RR
RR
RR
RR
ER
RR
RR
RR
ERP
ER
ER
4
ERER
FAA
P
F
FAG
AP
FAC
P
KP
SP
PIC
S
SC
ER ER
ER ER
RE
REP
ER
ER
RE
RE
RE
RE
RE
RE
ER
ER
ICNB PCCR
P
PIC
DS
RE RE
RE
RE
RE
REP
1V2D
REPX/HC
RE
RERE
M
M
ER
RE
RE RE
RE RE
NEW
ER
REP
RE
JRE
DSNEW
CRNEW
C
5
DR
J
6
C NEW
CNEW
INV
INV
4
C
INV7
ER
INV7
EMR
EMR
5
5
~
~
C
C
ECUH1EF-1
85C
C
ABOVE SUSPENDEDCEILING
ABOVE SUSPENDEDCEILING
NEW
1V2D
9
TO FIXTURE
J
Orange - ElectricalPart Plans E-1
JRP
AREA OF WORK
ER
DEMOLITION ABBREVIATIONEXISTING TO REMAIN (UNLESS OTHERWISE INDICATE, SHOWN FOR REFERENCE PURPOSE ONLY).
R EXISTING TO BE REMOVED. UNLESS OTHERWISE INDICATE, CONTRACTOR TO REMOVE ASSOCIATED WIRING AND CONDUIT BACK TO SOURCE.
RR EXISTING TO BE REMOVED AND RELOCATED. CONTRACTOR TO EXTEND ASSOCIATED WIRING AND CONDUIT TO NEW LOCATION.
ER
NEW WORK ABBREVIATIONEXISTING TO REMAIN (UNLESS OTHERWISE INDICATE, SHOWN FOR REFERENCE PURPOSE ONLY).
RE RELOCATED EXISTING
REP REPLACED EXISTING UNIT/DEVICE AND ASSOCIATED ACCESSORIES.
NEW PROVIDE NEW UNIT/DEVICE TO MATCH EXISTING MANUFACTURER. PROVIDE ALL CONNECTIONS TO EXISTINGCORRESPONDING SYSTEM. MATCH EXISTING WIRING TYPE AND SIZE. INSTALL AS PER MANUFACTURER REQUIREMENTAND PROVIDE ALL COMPONENTS NECESSARY FOR A COMPLETE OPERATIONAL INSTALLATION.
ERP EXISTING UNIT / DEVICE AND ASSOCIATED ACCESSORIES TO BE REPLACED AT NEW LOCATION, EXTEND ASSOCIATED WIRING AND CONDUIT TONEW LOCATION AS REQUIRED. REFER TO NEW WORK FOR ADDITIONAL INFORMATION.
Drawing Title:
Tel. 203 230 9007 Fax. 203 230 82473190 Whitney Avenue, Hamden, CT 06518-2340
SILVER / PETRUCELLI + ASSOCIATES
silverpetrucelli.com
Architects / Engineers / Interior Designers
Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
Orange Avenue School Entrance Upgrades
Milford, Connecticut 06461
Milford Public Schools
260 Orange Avenue
AUGUST 27, 2020
AS NOTED
20.084State Project Number: 084-0209A
1
2
3
1
NEW WORK KEY NOTES KEY PLAN: APPROXIMATE LOCATION OF EXISTING DOOR ACCESS CONTROL AND SECURITY CAMERA SYSTEM CABINETS2-NETBOX.
KEY PLAN: APPROXIMATE LOCATION OF EXISTING INTRUSION DETECTOR SYSTEM CABINETS AND NETWORK I/T RACK WITHPATCH PANEL AND SWITCHES.
KEY PLAN: APPROXIMATE LOCATION OF FOUR INVERTER CABINETS (SPECTRUM AND SYNCHRON) BELOW FLOOR. REWORKCABINET AS NECESSARY IF REQUIRED TO ACCOMMODATE NEW EMERGENCY LIGHTING.
APPROXIMATE LOCATION OF EXISTING ELECTRICAL PANEL "C" (SIEMENS) RATED 208Y/120V-3PH. REWORK AS REQUIRED TOACCOMMODATE NEW CIRCUITS. UPDATE DIRECTORY WITH NEW BRANCH CIRCUIT DESIGNATION.
PROVIDE 20A-1P, 3/4"C, 2#12, 1#12G TO CORRESPONDING.
ELECTRIC JUNCTION BOX TO SUIT ELECTRIFIED DOOR HARDWARE. UNIT TO BE MOUNTED ABOVE CEILING AND LOCATION TOBE COORDINATED IN THE FIELD WITH EXISTING CONDITION.
CONTRACTOR TO INTERCEPT EXISTING LIGHTING FIXTURE AND INTERCONNECT WITH LIGHTING EMERGENCY INVERTER VIAUL924 RELAY. REFER TO DETAIL IN SHEET E-2 AND KEY PLAN NOTES AND DRAWINGS FOR INVERTER LOCATION.
PROVIDE 20A-3P, 3/4"C, 3#12, 1#12G TO CORRESPONDING. REFER TO KEY NOTE AND PLAN FOR APPROXIMATE ELECTRICALPANEL LOCATION.
WIRING DEVICE AND COMMUNICATION OUTLET TO BE INSTALLED IN FURNITURE. CONNECT TO EXISTING CIRCUIT.CONTRACTOR TO PROVIDE 20A-1P, 3/4"C, 2#12, 1#12G FROM PANEL "C" IF EXISTING CIRCUIT IS NOT CAPABLE TO SUIT NEWCONNECTION.
2
3
4
5
SYMBOL LEGEND
CKT-XBRANCH CIRCUIT HOMERUN
CONDUIT AND WIRE
KP
J
IC
CR
S
PIC
NB
FACP
C
ABBREVIATIONLIGHTING FIXTURE TO BE INTERCONNECTED WITH INVERTER VIA UL924 RELAY.INV.
CEILING MOUNTED EXIT SIGN.
SINGLE POLE TOGGLE SWITCH WITH THERMAL OVERLOAD PROTECTION.
QUAD POWER RECEPTACLE.
DUPLEX POWER RECEPTACLE.
ELECTRIC JUNCTION BOX.
VOICE/DATA OUTLET, 4" X 4" OUTLET BOX WITH A 1 GANG COVER. PROVIDE WIRING BACK TO NEARESTNETWORK PATCH P[ANEL. V:X/D:X = NUMBER OF VOICE/DATA PORTS. CONTRACTOR TO MATCH EXISTINGNETWORK WIRE TYPE AND SIZE.
SECURITY ALARM KEYPAD.
ACCESS CONTROL CARD READER TO BE WALL MOUNTED IN SINGLE GANG. HID: 920PTNNEK00000. WIREBACK TO CORRESPONDING CABINET. REFER TO KEY NOTE AND PLAN FOR APPROXIMATE CABINET LOCATION.
AIPHONE - ENTRY INTERCOM SYSTEM WITH INTEGRATED CAMERA AND CARD READER. AIPHONE:
AIPHONE - TELEPHONE WITH MONITOR INTERCONNECTED WITH ENTRY INTERCOM SYSTEM. AIPHONE: IX-MV. PROVIDEEXPANSION COMPONENTS FOR INTERIOR UNIT TO ALLOW FOR SEPARATE RELEASE OF TWO DOORS. (INTERIOR ANDEXTERIOR) TYPICAL FOR TELEPHONE IN GREETING DESK AND MAIN OFFICE. PROVIDE CORRESPONDING BACK BOX TOSUIT FURNITURE INSTALLATION. PROVIDE (1) CAT6 CABLE AND (1) 18-4 WIRE AS REQUIRED TO SUIT RELOCATION.
STANDARD 3/4" RECESSED DOOR CONTACT TO SUIT ACCESS CONTROL DOOR. INTERLOGIX :1078C-N. FORNEW ACCESS CONTROL DOOR PROVIDE HYBRID CABLE (BANANA CABLE) TO SUIT NEW CONNECTION.REFER TO KEY NOTE AND PLAN FOR APPROXIMATE CABINET LOCATION.
KNOX BOX WITH KEYS.
REQUEST TO EXIT SENSOR FOR DOOR ACCESS CONTROL SYSTEM.
SECURITY SURVEYING VIDEO CAMERA. SONY: IPELA HD AND SILENT WITNESS. CONTRACTOR TO COORDINATEFINAL VIEW DIRECTION WITH OWNER. PROVIDE XPROTECT CORPORATE DEVICE LICENSE PER NEW CAMERA.MILESTONE: XPCODL. REFER TO KEY NOTE AND PLAN FOR APPROXIMATE CABINET LOCATION.
ADDRESSABLE FIRE ALARM CONTROL PANEL NOTIFIER. REFER TO KEY NOTE AND PLAN FOR APPROXIMATECABINET LOCATION.
FIRE ALARM SMOKE DETECTOR.
MCOUNTER TOP COMMUNICATION SYSTEM NORCON: #TTU-3X. INSTALL AS PER MANUFACTURER REQUIREMENTAND COORDINATE LOCATION WITH OWNER IN THE FIELD. PROVIDE WITH 120V POWER ADAPTER. ALL WIRESHALL BE CONCEALED AND NEATLY INSTALLED.
F FIRE ALARM PULL STATION UNIT.
SINGLE POLE LIGHT TOGGLE SWITCH.
2" X 4' RECESSED TROFFER FIXTURE WITH PRISMATIC LENS AND FLUORESCENT LAMPS. ALL RELOCATEDFIXTURES TO BE CLEANED (TYPICAL FOR ALL) AND RELAMP AND PROVIDED WITH NEW BALLAST (IF NOTOPERATIONAL)
2" X 4' RECESSED TROFFER FIXTURE WITH PRISMATIC LENS AND FLUORESCENT LAMPS. FIXTURE TO BEINTERCONNECTED WITH EMERGENCY LIGHTING INVERTER VIA UL 924 RELAY . ALL RELOCATED FIXTURES TOBE CLEANED (TYPICAL FOR ALL) AND RELAMP AND PROVIDED WITH NEW BALLAST (IF NOT OPERATIONAL).
EXTERIOR SURFACE MOUNTED FIXTURE.
WEATHERPROOF.WP
DRILLUMINATED PUSH BUTTON DOOR RELEASE TO BE MOUNTED ON A SINGLE GANG BOX. ALARM CONTROL:TS-2-2. PROVIDE (1) 18-4 TWISTED WIRE BACK TO CORRESPONDING CABINET. REFER TO KEY NOTE ANDPLAN FOR APPROXIMATE CABINET LOCATION.
PLOCKDOWN PUSH BUTTON TO BE MOUNTED ON A SINGLE GANG BOX. STI:SS2421EM-EN. INTERCONNECT WITHACCESS CONTROL AND SECURITY BURGLAR CABINETS VIA 18-4 WIRE SIZE. COORDINATE FINAL LOCATION WITHOWNER IN THE FIELD. REFER TO KEY NOTE AND PLAN FOR APPROXIMATE CABINET LOCATION.
DS
6
7
FAAP ADDRESSABLE FIRE ALARM REMOTE PANEL NOTIFIER. REFER TO KEY NOTE AND PLAN FOR APPROXIMATECABINET LOCATION.
FAAP ADDRESSABLE FIRE ALARM GRAPHIC REMOTE PANEL. REFER TO KEY NOTE AND PLAN FOR APPROXIMATECABINET LOCATION.
ADA FIRE ALARM SPEAKER / STROBE UNIT.
NOT ADA FIRE ALARM SPEAKER / STROBE UNIT.
8
9
Orange - ElectricalGen./Notes & Spec's. E-2
JRP
AND MC CABLE WHERE CONCEALED.
LIQUID-TIGHT FLEXIBLE METAL CONDUIT (MAX. LENGTH 5').
AND CONNECTICUT STATE FIRE SAFETY CODE AND SHALL BEA. ALL WORK SHALL COMPLY WITH CONNECTICUT STATE BUILDING CODE
RACEWAYS, BOXES AND FITTINGS
INSTALLATION WITH OTHER BUILDING COMPONENTS. REFER ALL
TEAR, WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER.
WORKING ORDER AND SHALL, WITHOUT ADDITIONAL CHARGE, REPLACE ANY WORK, MATERIALS, OR EQUIPMENT FURNISHED & INSTALLED BY HIM
UNDER THIS WHICH DEVELOP DEFECTS, EXCEPT FROM NORMAL WEAR &
REPLACE DEFECTIVE WORK OR WORK NOT CONFORMING TO REQUIREMENTS OF CONTRACT DOCUMENTS.
PERPENDICULAR TO OTHER BUILDING SYSTEMS AND
UNLESS INDICATED OTHERWISE.
& NEMA AND SHALL BE UL LISTED.
6. CONTRACTOR SHALL LEAVE THE ENTIRE ELECTRICAL SYSTEM IN PROPER
A. COMPONENTS AND INSTALLATION SHALL COMPLY WITH NFPA 70
3. INSTALL SYSTEMS LEVEL, PLUMB, PARALLEL AND
2. INSTALL SYSTEMS TO PROVIDE MAXIMUM HEADROOM POSSIBLE
4. INSTALL EQUIPMENT TO FACILITATE REPAIR, MAINTENANCE
CONFLICTS TO ENGINEER BEFORE CONTINUING WITH WORK.
5. PERFORM CUTTING AND PATCHING REQUIRED TO REMOVE AND
MANUALS WHERE REQUIRED BY INDIVIDUAL SPECIFICATION SECTIONS.
OTHERWISE AND SHALL BE LISTED BY UNDERWRITERS LABORATORIES.
2. SUBMIT THREE COPIES TO OWNER.
B. MATERIAL & EQUIPMENT SHALL BE NEW UNLESS SPECIFICALLY NOTED
1. COORDINATE ELECTRICAL SYSTEMS, EQUIPMENT AND MATERIALS
1. SUBMIT PRODUCT DATA, SHOP DRAWINGS, RECORD DRAWINGS AND O&M
C. EXTERIOR RACEWAYS ABOVE GROUND SHALL BE RIGID METAL CONDUIT OR
E. USE RACEWAY FITTINGS COMPATIBLE WITH ASSOCIATED RACEWAY
B. INTERIOR RACEWAYS SHALL BE ELECTRICAL METALLIC TUBING.
ACCOMPLISHED IN A NEAT AND WORKMAN LIKE MANNER.
WALLS AND FLOORS. APPLY UL LISTED FIRE STOPPING MATERIAL WHERE
AND INSTALLATION OF SUPPORTS AND CONFORM TO THE FOLLOWING:
FITTINGS SHALL CONFORM TO UL 514B.
D. INSTALL SLEEVES IN CONCRETE SLABS AND WALLS, AND FIRE RATED
C. CONFORM TO MANUFACTURER'S RECOMMENDATIONS FOR SELECTION
A. SUPPORTS, HARDWARE AND FASTENERS SHALL BE PROTECTED WITH
A. WIRE SHALL COMPLY WITH UL 83 AND NEMA WC-5. CONNECTORS SHALL
F. BOXES SHALL BE STEEL CONFORMING TO UL 514A AND NEMA OS1.
B. CONDUCTORS SHALL BE COPPER AND INSULATION SHALL BE THHN/THWN.
2. SUPPORT RACEWAY WITHIN ONE FOOT OF ANY UNSUPPORTED BOX.
B. SLEEVES SHALL BE SCHEDULE 40 GALVANIZED STEEL PIPE.
1. SUPPORT INDIVIDUAL HORIZONTAL RACEWAYS BY SEPARATE PIPE
A. PROVIDE EQUIPMENT IDENTIFICATION LABELS OF ENGRAVED PLASTIC LAMINATE FOR METER SOCKETS, PANELBOARDS & DISCONNECTS.
C. PROVIDE TYPED PANELBOARD CIRCUIT DIRECTORY FOR EACH PANELBOARD.
B. CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NFPA 70
C. INTERIOR WIRING SHALL BE BUILDING WIRE IN CONDUIT WHERE EXPOSED
ELECTRICAL GENERAL REQUIREMENTS
V.
AND ANSI A13.1.
ELECTRICAL IDENTIFICATION
HANGERS.
REQUIRED.
IV.
III.
ZINC COATING.
SUPPORTING DEVICES
BUILDING WIRE
COMPLY WITH UL 486A.
II.
AND APPLICATION.
OR REPLACEMENT.
COMPONENTS.
I.
C. SUBMITTALS:
D. ELECTRICAL INSTALLATION:
SCHEDULE 40 PVC.D. EXTERIOR RACEWAYS BELOW GROUND SHALL BE RIGID METAL CONDUIT OR
D. PROVIDE UNDERGROUND WARNING TAPE FOR ALL BURIED ELECTRICAL SERVICES.
ELECTRICAL SPECIFICATIONS
D. FIRE ALARM CABLE SHALL BE INSTALLED IN DEDICATED CONDUIT WHERE EXPOSED.
B. FURNISH DEVICE CAPABLE OF SERVING ALL COMPONENTS SHOWN.C. INSTALLED SYSTEM SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF
NFPA 72, NFPA 70, ADA, AND CONNECTICUT FIRE SAFETY CODE.
CONCEALED CABLE MAY BE RUN WITHOUT CONDUIT.
VI. FIRE ALARMA. MANUFACTURERS: MATCH EXISTING
E. COMPLETED SYSTEM SHALL BE FULLY TESTED IN ACCORDANCE WITH NFPA-72H BYCONTRACTOR IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE AND THE LOCALFIRE MARSHAL.
F. PROVIDE PRODUCT DATA SUBMITTALS.
GENERAL NOTES
1. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK REQUIRED FOR A COMPLETE, FULLY OPERABLEINSTALLATION. ALL WORK TO BE DONE IN ACCORDANCE WITH THE LATEST APPROVED ISSUE OF THE NEC ANDAPPLICABLE LOCAL CODES.
2. THIS IS AN EXISTING BUILDING, WITH AN EXISTING SERVICE. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TOSUBMITTING A BID TO ASCERTAIN FIELD CONDITIONS AS THEY EXIST AND JUDGE THEIR EFFECT ON THE WORK TO BE DONE.NO ALLOWANCE WILL BE MADE FOR FAILURE TO VISIT THE JOB SITE AND MAKE THIS DETERMINATION.
3. THE DRAWINGS SHOW THE GENERAL LAYOUT AND SOME OF THE DETAIL, BUT THEY DO NOT SHOW EVERY FITTING, BEND,ETC. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SUCH MATERIALS TO MAKE A COMPLETE INSTALLATION.
4. DO NOT SCALE DRAWINGS; ACTUAL FIELD MEASUREMENTS AND DIMENSIONS TAKE PRECEDENCE IN ALL CASES.
5. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD GENERAL CONDITIONS OF THE CONSTRUCTIONCONTRACT, AIA DOCUMENT 201, LATEST EDITION.
6. ELECTRICAL CONTRACTOR SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS ANDOR REQUIREMENTS FOR PROPER OPERATION AND MAINTENANCE.
7. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING OF ALL PHASES OF THE WORK AND TO DEMONSTRATETO OWNER THAT THE EQUIPMENT IS IN FULL OPERATING ORDER.
8. ELECTRICAL CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED TO THEIR ORIGINAL CONDITION. ELECTRICALCONTRACTOR IS RESPONSIBLE FOR ALL CUTTING, PATCHING, PAINTING, CLEAN-UP, ELECTRICAL DEBRIS REMOVAL ANDGENERAL COORDINATION OF THE WORK EFFORT AS REQUIRED FOR THE INSTALLATION OF THE ELECTRICAL ITEMS OFWORK.
9. THE TERM "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL IN COMPLETE WORKING ORDER.
10. THE SCOPE OF WORK IS AS SHOWN ON THE PLANS AND DETAILED IN THE SPECIFICATIONS.
11. ALL THE WIRE SIZES ARE BASED ON COPPER, ALUMINUM IS NOT TO BE USED.
12. ALL WIRING METHODS ARE TO BE IN ACCORDANCE WITH THE CURRENT ISSUE OF THE NATIONAL ELECTRICAL CODE, ANDAPPLICABLE LOCAL CODES. ALL WIRING IS TO BE IN CONDUIT, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL WIRING ISTO BE CONCEALED.
13. PROVIDE INDEPENDENT SEISMIC SUPPORT OF ALL ELECTRICAL EQUIPMENT PER INTERNATIONAL BUILDING CODE.
14. ELECTRICAL CONTRACTOR SHALL SECURE ALL PERMITS AND PAY FOR ALL REQUIRED FEES, INCLUDING ALL UTILITY FEES.
15. ELECTRICAL CONTRACTOR SHALL WARRANT AND GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OFONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER.
16. ELECTRICAL CONTRACTOR SHALL PROVIDE PROOF OF LIABILITY AND PROPERTY INSURANCE TO THE OWNER, ALLDEDUCTIBLES SHALL BE PAID FOR BY THE ELECTRICAL CONTRACTOR IN THE EVENT OF A CLAIM.
17. PERSONNEL SAFETY IS OF PRIME IMPORTANCE. NO HAZARDOUS CONDITION MUST BE ALLOWED. EVERY CARE MUST BETAKEN TO PROTECT CONSTRUCTION AND OTHER PERSONNEL. CLEANUP IS TO BE DONE ON A DAILY BASIS. ELECTRICALCONTRACTOR TO REMOVE AND DISPOSE OF REFUSE FROM SITE.
18. ELECTRICAL CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR APPROVAL FOR ALL EQUIPMENT, WIRING, CONDUIT,DISCONNECT, ... ETC.
19. COORDINATE EXACT PLACEMENT OF EQUIPMENT WITH MECHANICAL PLANS, MAKE FIELD ADJUSTMENTS AS REQUIRED TOAVOID CONFLICTS, VERIFY WITH OWNER.
20. ELECTRICAL CONTRACTOR TO COORDINATE WITH MECHANICAL CONTRACTOR FOR ITEMS SUPPLIED BY THEMECHANICAL/OTHER DIVISIONS BUT INSTALLED BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO REVIEWALL THE PLANS FOR THE PROJECT FOR ELECTRICAL WORK.
21. ELECTRICAL CONTRACTOR TO VERIFY ALL EQUIPMENT POWER NEEDS WITH THE ACTUAL SHOP DRAWINGS FOR THEEQUIPMENT TO BE USED, PRIOR TO STARTING ANY ELECTRICAL WORK.
22. SPECIFICATION SECTIONS, GENERAL CONDITIONS, SUPPLEMENTAL GENERAL CONDITIONS AND DRAWINGS AREINTEGRAL PARTS OF CONTRACT DOCUMENTS.
23. ALL ELECTRICAL PENETRATIONS TO BE FIREPROOFED TO MAINTAIN INTEGRITY OF FIRE WALLS/FLOORS/CEILINGS.
24. UPDATE EXISTING ELECTRICAL PANELBOARD DIRECTORY WITH NEW CIRCUIT BREAKER DESIGNATION AS REQUIRED.
25. THE DISPOSAL OF ALL UNUSED EXISTING ELECTRICAL EQUIPMENT REMOVED IS A PART OF THE SCOPE OFWORK. THE ELECTRICAL CONTRACTOR SHALL DISPOSE OF ALL SUCH EQUIPMENT, INCLUDING HAZARDOUS PCBCONTAINING BALLASTS, IN A MANNER CONSISTENT WITH STATE OF CT. DEPARTMENT OF ENVIRONMENTALPROTECTION REGULATIONS, CURRENT ISSUE.
26. SHARED NEUTRALS ARE NOT TO BE USED. PROVIDE SEPARATE NEUTRALS FOR ALL CIRCUITS.
27. PRIOR TO SUBMISSION OF BIDS GIVE WRITTEN NOTICE TO ENGINEER OF ANY MATERIAL OR APPARATUS THATIS INADEQUATE, UNSUITABLE FOR THE USE, IN VIOLATION OF LAWS, ORDINANCES, RULES, CODES OR ANYREGULATIONS OF AUTHORITIES HAVING JURISDICTION OR ANY NECESSARY ITEMS OF WORK THAT HAS BEENOMITTED. CONTRACTOR AFFIRMS THAT ABSENT SUCH NOTICE, ALL SYSTEMS WILL FUNCTION SATISFACTORILYWITHOUT ADDITIONAL EXTRA COMPENSATION.
28. ALL PART NUMBERS ARE PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR. THEY ARE NOT TO BECONSIDERED THE COMPLETE SPECIFICATION OF THE PRODUCT. THE PART NUMBER AND DESCRIPTION WILL BETHE COMPLETE SPECIFICATION. IN THE EVENT OF A DISCREPANCY BETWEEN THE TWO, THE MORE STRINGENT,MORE COSTLY FEATURE/PREFORMANCE WILL BE REQUIRED.
29. NO LOW VOLTAGE WIRING SHALL BE PERMITTED IN THE SAME RACEWAY AS POWER WIRING.
30. PROVIDE DRAG LINES IN ALL EMPTY RACEWAYS.
31. CIRCUIT NUMBERS ARE INDICATED FOR INTENT ONLY. THE ELECTRICAL CONTRACTOR SHALL ADJUSTACCORDINGLY IN THE FIELD, TO BALANCE CIRCUITS EVENLY ON ALL PHASES.
32. MINIMUM CONDUCTOR SIZE, UNLESS OTHERWISE NOTED SHALL BE #12 FOR ALL BRANCH CIRCUIT RUNS UPTO THE FIRST OUTLET; OVER 100 FEET, #10; OVER 150 FEET, #8; INCREASE CONDUIT SIZE TO SUIT.
33. ELECTRICAL CONTRACTOR TO VERIFY LOADS, SETTINGS, OVERCURRENT PROTECTION... ETC TO INSURECOMPATIBILITY OF EQUIPMENT.
34. NO PENETRATIONS ARE ALLOWED INTO STAIR ENCLOSURES EXCEPT AS REQUIRED FOR SERVICES UTILIZED INTHE STAIR.
35. REPAIR AND REPLACE AT NO COST TO OWNER ALL EQUIPMENT AND MATERIALS DAMAGED DURINGCONSTRUCTION.
36. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH BASE BUILDING ELECTRICIAN.
37. APPEARANCE OF ALL VISIBLE FEATURES IS OF ESPECIAL IMPORTANCE IN OCCUPIED AREAS. LOCATION SHOWNON DRAWINGS IS DIAGRAMMATIC AND NOT INTENDED TO DETERMINE EXACT LOCATION. CONTACT ARCHITECT TOREVIEW FINAL LOCATIONS PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN REQUIREMENT TORELOCATE.
38. PRODUCTS SHALL NOT BE INSTALLED IN PROMINENT LOCATIONS UNLESS NO ALTERNATIVE EXISTS. ITEMSSHALL BE CENTERED ON WALL OR CEILING TREATMENT AND ON ONE ANOTHER AS APPLICABLE. THISINCLUDES BUT IS NOT LIMITED TO ACCESS PANELS, LIGHTING FIXTURES, SWITCHES, THERMOSTATS, FIREALARM DEVICES, EXIT SIGNS, ELECTRICAL PANELS, AND ANNUNCIATOR PANELS OF ANY KIND.
39. ELECTRICAL CONDUITS & BOXES SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS WHEREVER POSSIBLE.
40. ALL INSTALLATIONS ON NEW WALLS SHALL BE FULLY RECESSED. INSTALLATIONS ON EXISTING MASONRY OR EXISTINGWALLS SHALL BE RUN WITH SURFACE WIREMOLD RACEWAY PAINTED TO MATCH WALL FINISHED AND SURFACEBOXES. INSTALLATIONS ON EXISTING STUD WALLS SHALL CUT IN OLD-WORK STYLE BOXES AND FISH WIRINGIN WALL CAVITY.
DEMOLITION NOTES
1. UNLESS OTHERWISE INDICATED, THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL INDICATED ELECTRICALEQUIPMENT, ACCESSORIES, CONTROLS, DEVICES, AND ASSOCIATED CONDUIT AND WIRING BACK TO SOURCE ORLAST DEVICE.
2. NO EQUIPMENT OR DEVICES THAT HAVE BEEN DISCONNECTED AND OR ABANDONED SHALL REMAIN.
3. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING SYSTEMS ANDCONDITIONS IN AREAS OF RENOVATION.
4. ANY SYSTEMS OR EQUIPMENT TO REMAIN ACTIVE DURING RENOVATION SHALL BE KEPT IN OPERATION BYPROVIDING TEMPORARY CONNECTIONS AS REQUIRED UNTIL NEW SYSTEMS ARE INSTALLED AND OPERATIONAL.
6. ANY ELECTRICAL EQUIPMENT TO BE REMOVED AND REUSED OR TURNED OVER TO THE OWNER, AT OWNERSREQUEST, OR AS INDICATED ON THE DRAWINGS SHALL BE CAREFULLY REMOVED AND STORED TO PREVENTDAMAGE.
7. THE ELECTRICAL CONTRACTOR SHALL ALSO REVIEW THE ARCHITECTURAL DEMOLITION DRAWINGS AS PART OF THISCONTRACT FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
8. ALL SERVICE INTERRUPTIONS SHALL BE COORDINATED AND APPROVED WITH THE OWNER IN ADVANCE PRIOR TOCOMMENCEMENT OF ANY WORK.
9. THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS DEMOLITION WORK WITH THAT OF OTHER TRADES IN ORDERTO AVOID CONFLICTS.
10. ELECTRICAL COMPONENTS SHOWN ON THE DEMOLITION DRAWINGS, AND THE ASSOCIATED CONDUIT, WIRE & BOXESARE TO BE REMOVED AND DISPOSED OF UNLESS SPECIFICALLY NOTED OTHERWISE.
11. ALL MATERIALS BEING REMOVED SHALL BE HANDLED IN A MANNER COMPLYING WITH ALL PERTINENT LAWS, CODESAND ENVIRONMENTAL REGULATIONS.
12. ALL REMOVED COMPONENTS SHALL BE LEGALLY DISPOSED OF BY CONTRACTOR UNLESS SPECIFICALLY NOTEDOTHERWISE.
13. WHERE EXISTING DEVICES ARE REMOVED & NO NEW DEVICES ARE INSTALLED IN THE SAME LOCATION, REMOVE ALLWIRING FROM BOX & PROVIDE PROPERLY SIZED BLANK COVER PLATE.
14. WHERE ELECTRICAL EQUIPMENT & DEVICES ARE BEING REMOVED, COORDINATE AND FIELD VERIFY IF BRANCH CIRCUITFEEDS THROUGH TO EQUIPMENT/DEVICES TO REMAIN. BRANCH CIRCUITS SHALL BE SPLICED OR RELOCATED TOMAINTAIN CONTINUATION OF SERVICES.
LIGHTING FIXTURE SCHEDULE
DESIGNATION DESCRIPTION MANUFACTURER/MODEL NUMBER
DRIVERCOLOR
TYPE
LAMP
TEMP NO
ELECTRICAL
VOLTAGE WATTS
1
2
NOTES
PROVIDE WITH ALL REQUIRED MOUNTING HARDWARE, AND CONNECTING CABLE.
PROVIDE W/ FEATURES AND ACCESSORIES NECESSARY FOR UNIVERSAL ( TOP, BACK AND END ) MOUNTING AND UNIVERSAL DIRECTIONAL ARROW KNOCKOUTS. ARROWS ONPLANS INDICATE DIRECTION OF CHEVRONS. SHADING INDICATES LOCATION OF FIXTURE FACE. CHEVRON AND LETTERING SHALL COMPLY W/ NFPA 101.
CONTRACTOR SHALL CONNECT EXIT SIGN AND EMERGENCY WALL PACK TO LOCAL LIGHTING BRANCH CIRCUIT AHEAD OF SWITCHING DEVICE.
ALL ADA SYMBOLS ARE TO BE THE NEW DYNAMIC CHARACTER, PURSUANT TO CONNECTICUT PUBLIC ACT NO. 16-78.
FIXTURE SHALL BE UL LISTED FOR WET LOCATION AND CAPABLE OF OPERATING IN COLD TEMPERATURE (0° F).
3
4
HC EXIT SIGN WITH DYMAMICWHEEL CHAIR SYMBOL TLA-EM-R-1-W
EVENLITELED - - 4UNV- 1 2
5
3 4
LIGHT FIXTURE SCHEDULE NOTES
5. CONTRACTOR SHALL REMOVE ALL FLUORESCENT LIGHT FIXTURE BALLASTS & IDENTIFY THOSE CONTAINING PCB'S. THESE SHALL BE TURNED OVER TO THE OWNER FOR DISPOSAL.
CONDUIT
CONDUIT
FIRESTOP SEALANT
SCHEDULE 40GALVANIZED PIPESLEEVE
FIRE OR SMOKE RATEDDRYWALL PARTITION
UL LISTED FIRESEALANT REFER TOPROJECT MANUAL
GROUT SLEEVE INMASONRY WALL
FIRE OR SMOKE RATEDCONCRETE/MASONRYWALL/FLOOR
SCHEDULE 40GALVANIZED PIPE SLEEVE
UL LISTED FIRESEALANT REFER TOPROJECT MANUAL
1. PROVIDE UL LISTED FIRE/SMOKE PENETRATION ASSEMBLY IN ACCORDANCEW/UL1479, ASTM E 814 REQUIREMENTS FOR WALL TYPE, RATING, PIPE SIZEINSTALLED.
2. FIRESTOPPING SHALL HAVE A RATING EQUAL TO OR GREATER THAN THEWALL/FLOOR BEING PENETRATED - SEE PROJECT MANUAL. REFER TOARCHITECTURAL DRAWINGS FOR WALL/FLOOR RATINGS AND LOCATIONS.
FLOOR
BASEBOARD
4"
LIGHT SWITCH
8"
18"
48"
(TYP. ALL OUTLETS UNLESS OTHERWISE NOTED.)
/
/
NOT TO SCALE
6'-8"
FIRE ALARM AUDIO/VISUAL UNIT.
DOOR FRAMEAND NO GREATER THAN 96 A.F.F.
BOTTOM
ENTIRE LENS SHALL BE LESS THAN 80"
CL
CL
NOTES :
1. ALL MOUNTING HEIGHTS SHALL BE MEASURED FROM FIN. FLOOR TO CENTERLINE OF DEVICE (EXCEPT FOREXIT SIGNS , FIRE ALARM PULL STATION AND LIGHTING SWITCH).
2. DEVICES SHALL BE INSTALLED ON A COMMON VERTICAL CENTERLINE WHEREVER POSSIBLE.
3. ALL DEVICES SHALL BE INSTALLED AT THE MOUNTING HEIGHTS INDICATED ON THIS DETAIL, UNLESSOTHERWISE NOTED.
4. THE LOCATION OF WALL OUTLETS ARE DIRECTLY RELATED TO THEFURNITURE LOCATION. SPECIAL ATTENTION SHALL BE GIVEN TO LOCATING OUTLETS PER THIS DETAIL. DONOT INSTALL OUTLETS BACK TO BACK.
FIRE ALARM PULL STATION
44"
COUNTER HEIGHT OUTLETSMTD. 6" ABOVE COUNTER OR BACK SPLASH
OR STRUCTURE EXCEEDS 102" A.F.F.PROVIDE PENDANT WHERE HUNG CEILING
102"
DEVICES SHALL BE INSTALLED ON ACOMMON VERTICAL CENTER LINE
WHEREVER POSSIBLEDUPLEX OR QUADRAPLEXRECEPTACLE
TELECOMMUNICATIONSOUTLET, CONDUIT &BACK BOX BY E.C.
UL924 RELAY NOTES
GTD20A TERMINALBLOCKS
"T1" "T2"
HOT
NEUTRAL
HOT
NEUTRAL
HOT
NEUTRAL
LOCALSWITCH
GTD20A(UL 924 RELAY)
CKT BKRPANEL
LIGHTINGLOAD
NOTES:
1. FOR EMERGENCY FIXTURES THAT WILL ONLY COME ON UPON LOSS OF NORMAL POWER, DONOT WIRE HOT LEG OF NORMAL CKT BKR TO TERMINAL BLOCK T1-7.
SEE NOTE-1
NOT TO SCALE
INVERTER
EMR
Drawing Title:
Tel. 203 230 9007 Fax. 203 230 82473190 Whitney Avenue, Hamden, CT 06518-2340
SILVER / PETRUCELLI + ASSOCIATES
silverpetrucelli.com
Architects / Engineers / Interior Designers
Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
Orange Avenue School Entrance Upgrades
Milford, Connecticut 06461
Milford Public Schools
260 Orange Avenue
AUGUST 27, 2020
AS NOTED
20.084State Project Number: 084-