(ESTABLISHED AS PUBLIC HIGHWAY BY BY-LAW No. 92-76, INSTRUMENT RO652165)
AutoCAD SHX Text
(ROAD ALLOWANCE BETWEEN LOTS 18 & 19, CONCESSION 1)
AutoCAD SHX Text
(KNOWN AS)
AutoCAD SHX Text
(ROAD ALLOWANCE BETWEEN CONCESSION 1 & BROKEN FRONT CONCESSION)
AutoCAD SHX Text
CORNER
AutoCAD SHX Text
#4
AutoCAD SHX Text
NORTHWEST
AutoCAD SHX Text
28.93
AutoCAD SHX Text
15.73
AutoCAD SHX Text
57.55
AutoCAD SHX Text
57.82
AutoCAD SHX Text
24.87
AutoCAD SHX Text
27.23
AutoCAD SHX Text
28.21
AutoCAD SHX Text
25.61
AutoCAD SHX Text
28.09
AutoCAD SHX Text
WEST FACE OF WALL ON LINE
AutoCAD SHX Text
17.40
AutoCAD SHX Text
15.71
AutoCAD SHX Text
25.59
AutoCAD SHX Text
210.04
AutoCAD SHX Text
(C1&M)
AutoCAD SHX Text
25.85
AutoCAD SHX Text
25.76
AutoCAD SHX Text
25.02
AutoCAD SHX Text
IN INSTRUMENT NR409485
AutoCAD SHX Text
N73%%d38'45"W
AutoCAD SHX Text
221.00
AutoCAD SHX Text
(P1,P2&M)
AutoCAD SHX Text
(221.04 P3,P4,P5)
AutoCAD SHX Text
(P1,P3,P4,P5&M)
AutoCAD SHX Text
DRIVEWAY
AutoCAD SHX Text
OF LOT 18
AutoCAD SHX Text
N62%%D05'00"W 20.89
AutoCAD SHX Text
RESULTANT TIE CALC FROM P2
AutoCAD SHX Text
(ESTABLISHED AS PUBLIC HIGHWAY BY
AutoCAD SHX Text
BY-LAW No. 99-56, INSTRUMENT RO757054)
AutoCAD SHX Text
(ESTABLISHED AS PUBLIC HIGHWAY BY
AutoCAD SHX Text
BY-LAW No. 99-56, INSTRUMENT RO757054)
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
L
AutoCAD SHX Text
1
AutoCAD SHX Text
FH
AutoCAD SHX Text
FH
AutoCAD SHX Text
FFE=83.27
AutoCAD SHX Text
FFE=83.27
AutoCAD SHX Text
PHASE LIMIT
AutoCAD SHX Text
EX 375mm STM @ 0.30%
AutoCAD SHX Text
M
AutoCAD SHX Text
B
AutoCAD SHX Text
EX STM MH N INV 81.33 E INV 81.31 W INV 81.32
AutoCAD SHX Text
EX 90.5m-525mm SAN @ 0.21%
AutoCAD SHX Text
EX SAN MH E INV 79.47 W INV 79.51 S INV 79.64 N INV 79.75
AutoCAD SHX Text
EX 250mm WATERMAIN
AutoCAD SHX Text
EX 81.9m-375mm STM @ 0.23%
AutoCAD SHX Text
EX 96.3m-525mm SAN @ 0.18%
AutoCAD SHX Text
EX 250mm WATERMAIN
AutoCAD SHX Text
EX 450mm STM @ 0.30%
AutoCAD SHX Text
EX 22.0m-450mm STM
AutoCAD SHX Text
EX 525mm SAN @ 1.0%
AutoCAD SHX Text
EX 59.7m-600mm STM @ 0.27%
AutoCAD SHX Text
EX 23.0m-525mm STM
AutoCAD SHX Text
EX STM INV 81.99 (ROOF LEADER)
AutoCAD SHX Text
EX 375mm STM @ 0.30%
AutoCAD SHX Text
EX STM MH E INV 81.13 W INV 81.15 N INV 81.16
AutoCAD SHX Text
EX SAN MH W INV 79.28 E INV 79.24 N INV 79.43 S INV 79.43
AutoCAD SHX Text
EX STM MH E INV 81.52 S INV 81.56 N INV 81.54
AutoCAD SHX Text
M
AutoCAD SHX Text
B
AutoCAD SHX Text
EX SAN MH E INV 79.68
AutoCAD SHX Text
EX 200mm SAN @ 1.0%
AutoCAD SHX Text
BREAK INTO EX. 525mm SAN SEWER ANDCONNECT NEW 200mm SAN SERVICE CONNECTIONEX 525mm INV 79.38PR 200mm INV 79.55
AutoCAD SHX Text
7.3m-200mm SAN @ 2.0%
AutoCAD SHX Text
BREAK INTO TO EX. 250mm WMAND CONNECT NEW 200mm WMSERVICE CONNECTION WITH CUT IN 250x250x200 TEE
AutoCAD SHX Text
200mm W/M
AutoCAD SHX Text
200mm V&B
AutoCAD SHX Text
100mm V&B
AutoCAD SHX Text
200mm V&B
AutoCAD SHX Text
SAN MH T/G 83.45 S INV 79.70 N INV 79.73
AutoCAD SHX Text
SAN PLUG INV 79.76
AutoCAD SHX Text
EMERGENCY OVERFLOW AND ACCESS HATCH. LID PER OPSD 401.010 'TYPE B' BOLTED
AutoCAD SHX Text
200mm W/M
AutoCAD SHX Text
200mm V&B
AutoCAD SHX Text
100mm V&B
AutoCAD SHX Text
SAN PLUG INV 79.87
AutoCAD SHX Text
SAN MH T/G 83.45 S INV 79.82 N INV 79.85
AutoCAD SHX Text
EMERGENCY OVERFLOW AND ACCESS HATCH. LID PER OPSD 401.010 'TYPE B' BOLTED
AutoCAD SHX Text
INSTALL NEW STM MH PER OPSD 701.013 EX. W INV 81.36 EX. E INV 81.36 PR. N INV 81.48
AutoCAD SHX Text
BREAK INTO TO EX. 250mm WM ANDCONNECT NEW 200mm WM SERVICECONNECTION WITH CUT IN 250x250x200 TEE
AutoCAD SHX Text
11.1m-300mm mm STM @ 2.0%
AutoCAD SHX Text
STM MH T/G 83.20 S INV 81.70 N INV 81.73
AutoCAD SHX Text
STM PLUG N INV 79.75
AutoCAD SHX Text
STM PLUG N INV 81.68
AutoCAD SHX Text
STM MH T/G 83.20 S INV 81.63 N INV 81.66
AutoCAD SHX Text
CONTRACTOR TO RESTORE EX. BOULEVARD AND PAVEMENT TO EX. CONDITION OR BETTER
AutoCAD SHX Text
BREAK INTO EX. 600mm STM SEWER ANDCONNECT NEW 300mm SAN SERVICE CONNECTIONEX 600mm INV 81.21PR 300mm INV 81.41
AutoCAD SHX Text
11.1m-300mm mm STM @ 2.0%
AutoCAD SHX Text
SIAMESE CONNECTION
AutoCAD SHX Text
SIAMESE CONNECTION
AutoCAD SHX Text
CONTRACTOR TO RESTORE EX. BOULEVARD AND PAVEMENT TO EX. CONDITION OR BETTER
AutoCAD SHX Text
CONTRACTOR TO RESTORE EX. BOULEVARD AND PAVEMENT TO EX. CONDITION OR BETTER
AutoCAD SHX Text
TOWN OF GRIMSBY AS-CONSTRUCTED DRAWING REFERENCE: HE611 SHEET 1 (FEBRUARY 1999)
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
SCALE: 1:300
AutoCAD SHX Text
10
AutoCAD SHX Text
0m
AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
4 WINDWARD DRIVE TOWN OF GRIMSBY REGIONAL MUNICIPALITY OF NIAGARA
AutoCAD SHX Text
Drawing
AutoCAD SHX Text
Project
AutoCAD SHX Text
BENCHMARK NOTE: : ELEVATIONS SHOWN HEREON ARE GEODETIC AND ARE RELATED TO TOWN OF GRIMSBY BENCHMARK No. 00819748495, HAVING AN ELEVATION OF 91.765 METRES. SURVEY NOTES: : TOPOGRAPHIC SURVEY COMPLETED BY KRCMAR SURVEYORS LTD. ON NOVEMBER 28, 2017. FILE No.: 17-219TP01 AS-BUILT: : LOCATION AND INFORMATION OF SANITARY, STORM AND WATERMAIN ON WINWARD DRIVE BASED ON TOWN OF GRIMSBY AS CONSTRUCTED DRAWINGS, TOWN OF GRIMSBY AS CONSTRUCTED DRAWINGS, AS CONSTRUCTED DRAWINGS, PROJECT No. HE611, DRAWING No. 1, DATED FEBRUARY 1999. SITE PLAN NOTES: : DESIGN ELEMENTS SHOWN ARE BASED ON SITE PLAN PREPARED BY WZMH ARCHITECTS. DRAWING No.: A-104 RECEVED (2019/10/29) DRAWING NOTES: : THIS DRAWING IS THE EXCLUSIVE PROPERTY OF C.F. CROZIER & ASSOCIATES INC. AND THE REPRODUCTION OF ANY PART OF IT WITHOUT PRIOR WRITTEN CONSENT OF THIS OFFICE IS STRICTLY PROHIBITED. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, AND DATUMS ON SITE AND REPORT ANY DISCREPANCIES OR OMISSIONS TO THIS OFFICE PRIOR TO CONSTRUCTION. THIS DRAWING IS TO BE READ AND UNDERSTOOD IN CONJUNCTION WITH ALL OTHER PLANS AND DOCUMENTS APPLICABLE TO THIS PROJECT. DO NOT SCALE THIS DRAWING. ALL EXISTING UNDERGROUND UTILITIES TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
AutoCAD SHX Text
Project No.
AutoCAD SHX Text
Dwg.
AutoCAD SHX Text
Design
AutoCAD SHX Text
Check
AutoCAD SHX Text
Drawn
AutoCAD SHX Text
Check
AutoCAD SHX Text
Drawing
AutoCAD SHX Text
Project
AutoCAD SHX Text
P.S.
AutoCAD SHX Text
P.S.
AutoCAD SHX Text
Engineer
AutoCAD SHX Text
Engineer
AutoCAD SHX Text
YYYY/MMM/DD
AutoCAD SHX Text
No.
AutoCAD SHX Text
2019/DEC/03
AutoCAD SHX Text
ISSUED FOR SUBMISSION
AutoCAD SHX Text
ISSUE / REVISION
AutoCAD SHX Text
0
AutoCAD SHX Text
Scale
AutoCAD SHX Text
1473-4779
AutoCAD SHX Text
S.C.S.
AutoCAD SHX Text
N.C./N.M.
AutoCAD SHX Text
1:300
AutoCAD SHX Text
SITE LOCATION
AutoCAD SHX Text
QUEEN ELIZABETH WAY
AutoCAD SHX Text
WINSTON RD.
AutoCAD SHX Text
LAKE ONTARIO
AutoCAD SHX Text
QUEEN ELIZABETH WAY
AutoCAD SHX Text
WINDWARD DR.
AutoCAD SHX Text
NOT FOR CONSTRUCTION
AutoCAD SHX Text
N
AutoCAD SHX Text
PRELIMINARY SITE SERVICING PLAN
AutoCAD SHX Text
EXISTING WATERMAIN
AutoCAD SHX Text
EXISTING STORM SEWER & MANHOLE
AutoCAD SHX Text
EXISTING SANITARY SEWER & MANHOLE
AutoCAD SHX Text
PROPOSED WATERMAIN
AutoCAD SHX Text
PROPOSED SANITARY SEWER & MANHOLE
AutoCAD SHX Text
PROPOSED WATER METER TO BE INSTALLED INSIDE OF BUILDING PER MECHANICAL DETAILS AND SPECIFICATIONS
AutoCAD SHX Text
PROPOSED BACKFLOW PREVENTOR TO BE INSTALLED INSIDE OF BUILDING PER MECHANICAL DETAILS AND SPECIFICATIONS
AutoCAD SHX Text
M
AutoCAD SHX Text
B
AutoCAD SHX Text
PROPERTY LINE
AutoCAD SHX Text
EXISTING FENCE
AutoCAD SHX Text
BUILDING ENTRANCE (PERSONNEL DOOR)
AutoCAD SHX Text
PROPOSED MAJOR OVERLAND FLOW DIRECTION
AutoCAD SHX Text
PROPOSED SIAMESE (FIRE DEPT.) CONNECTION
AutoCAD SHX Text
PARKING GARAGE ENTRANCE (OVERHEAD DOOR)
AutoCAD SHX Text
UNDERGROUND PARKING GARAGE OUTLINE
AutoCAD SHX Text
PROPOSED AREA DRAIN TO BE INSTALLED PER MECHANICAL DESIGN AND SPCIFICATIONS
AutoCAD SHX Text
PROPOSED SIAMESE CONNECTION
AutoCAD SHX Text
PROPOSED FIRE HYDRANT & GATE VALVE
AutoCAD SHX Text
PROPOSED STORM SEWER & MANHOLE
AutoCAD SHX Text
EXISTING SERVICE TO BE REMOVED
AutoCAD SHX Text
AD
AutoCAD SHX Text
EXISTING UTILITIES AND SERVICES CONTRACTOR SHALL NOTE THAT THE CONSTRUCTION ZONE HAS NUMEROUS EXISTING UNDERGROUND UTILITIES AND SERVICES, SOME OF WHICH ARE TO BE ABANDONED OR REMOVED, AND OTHERS WHICH ARE TO BE PROTECTED AND MAINTAINED IN SERVICE. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL RETAIN THE SERVICES OF A COMPANY, WHICH SPECIALIZES IN SUBSURFACE UTILITY ENGINEERING FOR THE PURPOSES OF LOCATING, MARKING AND SURVEYING ALL UNDERGROUND UTILITIES AND SERVICES. ALL CURRENT METHODS SHALL BE USED FOR THESE LOCATIONS INCLUDING ELECTRONIC METHODS, VACUUM EXCAVATIONS, SURVEYING MANHOLES AND CHAMBERS ETC. THE UTILITIES AND SERVICES SHALL BE SURVEYED AND TIED INTO THE PROJECT COORDINATE SYSTEM. A COPY OF THE SURVEY SHALL BE PROVIDED TO THE ENGINEER FOR RECORD PURPOSES. ANY CONFLICT WITH THE PROPOSED WORKS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL LOCATIONS FOR PROTECTION AND TEMPORARY RELOCATION OF UNDERGROUND UTILITIES AND SERVICES AS REQUIRED FOR THE COMPLETE INSTALLATION OF THE PROPOSED WORKS.
AutoCAD SHX Text
THE LIMITS OF MUNICIPAL ROW DISTURBED AREAS TO BE REINSTATED ARE APPROXIMATE AND SHALL BE REVIEWED BY TOWN PRIOR TO FINAL RESTORATION.