Programmable Range Power Tester
Example LED Driver’s Specification - INPUT : 170-270 V~0.2 A, 50-60 HzOUTPUT : 5 V 1 AEFFICIENCY - 80%
output wattage ~ 4 Watt
170 V
270 VN
We can Test Led Drivers on 16 Channel over its range and also program their Cycle of switching
You can also give relay timing for switching between two voltages
Channel 1
Channel 2
Channel 3
Channel 16
Connection Diagram
Limit Set
Software SnapShot
prpt-16
Cyclic Switching Between Ranges
User programmable Switching Time
Limit Set
Software Interface
16 Channel output/Measurement
Here you can give timing for switching of relays.This will be transferred toPRPT-16 meter.So No need of computer in Production Testing.
By this you can do range testing,Testing on Voltage fluctuation,On-Off Testing etc
(Burn-in Tester)
L N
Limits can set by software
CONNECTION DIAGRAM
D1 D2 D3 D4 D13 D14 D15 D16D11D8 D9D5 D10D7D6 D12
D1- D16 are loads (LED Driver, SMPS)
Power and Current included in 16 channel power measurement
Red LED shows the current and power limit fail in the load (LED Driver)
LN
270 V170 V
SSR
Controller
16 CHANNEL POWERMEASUREMENT
LED Driver Load
MCB
Green LED shows that Load is running without failure
CTs
SIGNAL TO SSR
N
PRPT-16
Testing of multiple Drivers in single Channel You can also test more than 16 no. of LED Drivers using Cyclic Load Tester
D1
D2
D3
D4
D13
D14
D15
D16
D11
D8
D9
D5
D10
D7
D6
D12
16 C
HA
NN
EL P
OW
ER
ME
ASU
RE
ME
NT
CTs
You can connect multiple Drivers in parallel.
Load No Wattage
D16 8.1
D15 8.2
D14 5.1
D13 8.5
D12 4.9
------ —---
—--- ------
D1 8.3
In above D14 has two Drivers of 4.1 W So Total W = 4.1*2 = 8.2So we set here the watt limit to 8.If any driver is fail then Related Load RED LED will show.
But using multiple driver in one channel may produce fault result.If you are using Two Drivers and both are fail, then one driver canProduce more voltage or increase the wattage and other can beproduce low wattage then total affect will be under the set wattage Limit .
For above Example if at D14 Driver 1 produces 4.9 W and Driver 2 produces 3.2wThen Total Wattage = 4.9+3.2 =8.1 W
So the total effect is above 8W and This will not detected.
Here every Channel has two drivers of 4.1 Watt each.
So we set the limit to 8 watt.
In below table One Driver in Channel 14 and 12 are fail which is showing in red row
Front Face of PRPT-16
LEDs for showing Status of Load
USB For PC Communication
Back View of PRPT-16
LCD Display shows Current in 4 Channels, Third Row Shows Step Running and Relay Status,Fourth Row shows Time set in given Step
16 Terminals to connect Loads
On/Off Power Switch
Buttons for changing displayand Control Settings
SSR for Switching and Input Voltage
Auxiliary Power Supply
Fuse to protect PRPT-16Always use good quality fuse
1 32 4 5 6 7 8 9 10 11 12 13 14 15 16
1 32 4 5 6 7 8 9 10 11 12 13 14 15 16
Red LED shows the current and power limit fail in the load (LED Driver)
Green LED shows that Load is running without failure
Proposed Design of PRPT-16
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
A
H
P
S
USB(Optical Isolated)
ON
OFF
Programable range Power tester
EMBUILTTECHNOLOGIESee
Visualizing Energy
TM
PRPT-16
1
5
9
13
2
6
10
14
3
7
11
15
4
8
12
16
USB Port for Software Interface
OUTPUT
Relays Input(Middle terminal is connected to Neutral.Sides are connected to Voltage Source)
Software Snapshot of PRPT-16
Enter Model No and Version for which you are setting Limits.This will save in meter
Enter the Voltage connected to relay This is only for graphing on switching Cycle Page
Click here to add more Timeset for relay Switching
Select the Relay and enter the time for switching
Shows the Switching Cycle based on the voltage given and time set
This information will transfer to the PRPT-16 Meter by USB
Enter the Voltage limit for testing.It will off the relays beyond the set limit so Load will work on the safe voltage region
Enter the Watt Limits for testing so if any driver is fail, corresponding red LED will on.
Voltage limit protects your loads from low and high voltages
So no need to connect the computer on production testing
Software Snapshot of PRPT-16
Enter Company NameModel No and Version will be set on Configuration page.
You can put your notes here
Enter Testing Person Name
Select if you wants to open the pdf after creation
Click here to generate PDF
Notes :- Features in Demo and User Version
Currently Demo version has 15 Channels.User version will be available with 16 Channels.
Demo versions has low accuracy.Accuracy will be increased at User Version.
Display size of Demo Version is 16X2.User Version will be available with 16X4 LCD.
Demo version is started from its initial stage when it goes off.In user version it will start from its previous state.
If required, SSR Can be replaced by Contactor.But we recommend to use SSR .
Demo version has Green LED for load and Yellow LED for Fail Indication.In user version Yellow LED will be replaced by Red LED.
Proposed Selector Switch for Changing Test Modes
OFF
Relay1
Relay2
Rapid Mode
Auto Mode
In this mode no relay will be ON.
In this mode Relay 1 will be ON
In this mode Relay 2 will be ON
In this mode user defined Cyclic Switching will ON
In this mode Automatic Switching of Relays with time period of 2 Seconds will ON
We are also proposed to use Selector Switch for changingthe Test Mode.
Buttons Function of Auto Volt Switcher
S
R W/A
SP
RapidMode
Watt/Amp
ProgMode
Up/ Set
(For Demo Version)
RRapidMode
Start Rapid Mode Stop Rapid Mode
PProgMode
PProgMode PProgMode Start User Defined Cycle Stop User Defined Cycle
W/AWatt/Amp Display Shows Watt Display Shows Current
SSUp/ Set Display Shows Next Parameter
Press for 5 seconds
Setting Page will show
Press for 5 seconds
Restart User Defined Cycle from initial State